VL6000 BEAM CE COMPLIANCE DOCUMENTS
David Valentine Entertainment GBU
January 23, 2017
Philips Lighting
EC Declaration of Conformity, EC DoC
EC Declaration of Conformity
We, Philips Entertainment Lighting,
10911 Petal Street Dallas, Texas 75238-2424 USA
Internal Ref. Nr.:86-0948 Year in which CE Mark was first affixed: 2017
Declare under our responsibility for the products:
Product Range: Professional Luminaire
Product Code: VL6000 BEAM (20.9708.0001)
The designated products are in conformity with the essential requirements of the following European Directives and harmonized standards:
Low Voltage Directive (LVD), 2014/35/EU
EN 60598-2-17:1989 + A2:1991 used in conjunction with EN 60598-1:2008 + A11:2009
Electromagnetic compatibility Directive (EMC), 2014/30/EU
EN 55015:2006 + A1:2007, EN 61547: 1995, EN 61000-3-2:2014, EN 61000-3-3:2013,
Restriction of the use of certain Hazardous Substances in electrical and electronic equipment Directive(RoHS), 2011/65/EU
EN 50581:2012
17 January 2017 David Garcia
Q&R Manager, Business Entertainment
Philips Entertainment LIghting 10911 Petal Street Dallas, TX 75238-2424 USA
2017
Dear Customer
Philips Lighting Professional Stage and Studio Luminaires take its compliance with
European Union Directive 2011/65/EU Restriction of Hazardous Substances (ROHS) very
seriously. As part of our ongoing compliance commitment, we have completed a process to identify
which, if any, substances are contained within the product we supply to you.
This communication refers to the latest version of RoHS
Manufacturer Part Numbers: 20.9708.0001 VL6000 BEAM LUMINAIRE Date of Product Release January 2017
Date of Review: 29 January 2017
As part of this RoHS identification process we have:
reviewed internal/publicly available engineering data in relation to the presence of
RoHS in our products or any of their component parts;
reviewed available safety data sheets for all our input materials;
Communicated with our suppliers to exclude/confirm the presence of listed RoHS in
any component parts of our products.
As a result of this process, we confirm that, to the best of our knowledge, the product we
currently supply to you meets the RoHS directive.
Sincerely,
David Valentine Field Quality & Regulatory Engineer
Test Report issued under the responsibility of: Intertek Testing Services NA Inc
TEST REPORT IEC 60598-2-17
Luminaires Part 2: Particular requirements
Section 17: Luminaires for stage lighting, television and film studios (outdoor and indoor)
Report Number. .............................. : 102761244DAL-002
Date of issue ................................... : 2017-01-16
Total number of pages .................... 47
Name of Testing Laboratory preparing the Report ...................... :
Intertek Testing Services NA Inc
Applicant’s name ............................ : Genlyte Thomas Group, LLC
Address ........................................... : 10911 Petal street
Dallas TX, 75238, USA
Test specification:
Standard .......................................... : IEC 60598-2-17:1984 (First Edition) + A1:1987 + A2:1990 used in conjunction with IEC 60598-1:2014 (Eighth Edition)
Test procedure ............................... : Informative test report for technical file & to support manufacturer’s Declaration of Conformity to European Directive 2014/35/EU (Low Voltage Directive)
Non-standard test method ............. : N/A
Test Report Form No. ..................... : IEC60598_2_17D
Test Report Form(s) Originator..... : Intertek Semko AB
Master TRF ...................................... : 2015-08
Copyright © 2015 IEC System of Conformity Assessment Schemes for Electrotechnical Equipment and Components (IECEE System). All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context.
If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB Scheme procedure shall be removed.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
General disclaimer:
The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing CB Testing Laboratory. The authenticity of this Test Report and its contents can be verified by contacting the NCB, responsible for this Test Report.
Page 2 of 47 Report No. Error! Reference source not found.
TRF No. IEC60598_2_17D
Test item description ....................... : HID Moving Head Luminaire
Trade Mark ........................................ : Vari-Lite
Manufacturer .................................... : Genlyte Thomas Group, LLC
Model/Type reference ...................... : VL6000 BEAM
Ratings .............................................. : 220 – 240 Vac, 11A 50/60Hz, 50°C Ambient
Responsible Testing Laboratory (as applicable), testing procedure and testing location(s):
CB Testing Laboratory:
Testing location/ address ............................. :
Associated CB Testing Laboratory:
Testing location/ address ............................. :
Tested by (name, function, signature) ........ :
Approved by (name, function, signature) ... :
Testing procedure: CTF Stage 1:
Testing location/ address ............................. :
Tested by (name, function, signature) ........ :
Approved by (name, function, signature) ... :
Testing procedure: CTF Stage 2:
Testing location/ address ............................. :
Tested by (name + signature) ...................... :
Witnessed by (name, function, signature) . :
Approved by (name, function, signature) ... :
Testing procedure: CTF Stage 3:
Testing procedure: CTF Stage 4:
Testing location/ address ............................. :
Tested by (name, function, signature) ........ :
Witnessed by (name, function, signature) . :
Approved by (name, function, signature) ... :
Supervised by (name, function, signature) :
Page 3 of 47 Report No. Error! Reference source not found.
TRF No. IEC60598_2_17D
Testing procedure: LVD
Testing location/ address ............................. : Intertek Testing Services NA Inc.
1809 10th Street., Suite 400
Plano, TX 75074 USA
Tested by (name, function, signature) ........ : Fred Momanyi
Approved by (name, function, signature) ... : Mike Watson
List of Attachments (including a total number of pages in each attachment):
Attachment 1 - EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES, pages 42 - 43
Attachment 2 – PHOTOS, pages 44 - 47
Summary of testing:
Tests performed (name of test and test clause):
TEST PERFORMED EN 60598-2-17 (EN 60598-1)
Test of Marking 17.5 (3.4)
Screw Torque Test 17.6 (4.12.1)
Impact Test 17.6 (4.13.1)
Straight Test Finger 17.6 (4.13.3)
Mechanical Load Test 17.6 (4.14.1)
Flexing Test 17.6 (4.14.3)
Protective Shield Test 17.6.3 (-)
Mechanical Load Test 17.6.4 (-)
Secondary Suspension Test 17.6.6 (-)
Provision for Earthing 17.8 (7.2.1-7.2.3)
Protection Against Electric Shock Test 17.11 (8.2.5)
Capacitor Discharge Test 17.11 (8.2.7)
Endurance Test 17.12 (12.3)
Thermal test (normal operation) 17.12 (12.4)
IP 23 Test 17.13 (9.2)
Humidity Test 48 H 17.13 (9.3)
Insulation Resistance Test 17.14 (10.2.1)
Electric Strength Test 17.14 (10.2.2)
Touch Current 17.14 (10.3)
Testing location:
Intertek Testing Services NA Inc.
1809 10th Street., Suite 400
Plano, TX 75074
USA
Page 4 of 47 Report No. Error! Reference source not found.
TRF No. IEC60598_2_17D
Summary of compliance with National Differences:
List of countries addressed: EN
The product fulfils the requirements of EN 60598-2-17:1988 + A2:1991 used in conjunction with
EN 60598-1:2008 + A11:2009.
Page 5 of 47 Report No. Error! Reference source not found.
TRF No. IEC60598_2_17D
Copy of marking plate:
Page 6 of 47 Report No. Error! Reference source not found.
TRF No. IEC60598_2_17D
Marking also includes
“Do not stare at the operating light source Risk Group 2 Caution Possibly hazardous optical radiation emitted from this product”
Page 7 of 47 Report No. Error! Reference source not found.
TRF No. IEC60598_2_17D
Test item particulars...................................................:
Classification of installation and use.......................: 50°C Ambient, IP 23
Supply Connection .....................................................: 220 – 240 Vac, 11A, 50\60Hz
.......................................................................................:
Possible test case verdicts:
- test case does not apply to the test object ........... : N/A
- test object does meet the requirement .................. : P (Pass)
- test object does not meet the requirement ........... : F (Fail)
Testing .......................................................................... :
Date of receipt of test item ........................................ : 2016-10-20
Date (s) of performance of tests ............................... : 2016-10-21 to 2017-01-16
General remarks:
"(See Enclosure #)" refers to additional information appended to the report. "(See appended table)" refers to a table appended to the report.
Throughout this report a comma / point is used as the decimal separator.
Clause numbers between brackets refer to clauses in IEC 60598-1
Manufacturer’s Declaration per sub-clause 4.2.5 of IECEE 02:
The application for obtaining a CB Test Certificate includes more than one factory location and a declaration from the Manufacturer stating that the sample(s) submitted for evaluation is (are) representative of the products from each factory has been provided ............................................................... :
Yes
Not applicable
When differences exist; they shall be identified in the General product information section.
Name and address of factory (ies) .......................... : Genlyte Thomas, LLC
10911 Petal street
Dallas TX, 75238, USA
General product information:
The products are stage and studio luminaires for use by professionals. They are to be permanently connected and are to be mounted to the support by brackets provided. Refer to report 102761244DAL-003 report for details on photobiological testing.
Page 8 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
17.2 (0) GENERAL TEST REQUIREMENTS P
17.2 (0.1) Information for luminaire design considered ............ : Yes No
Lamp standard:
17.2 (0.3) More sections applicable ............................................ : Yes No
Section/s:
17.4 (2) CLASSIFICATION P
17.4 (2.2) Type of protection .................................................... : Class I P
17.4 (2.3) Degree of protection ................................................. : IP 23 P
17.4 (2.4) Luminaire suitable for direct mounting on normally flammable surfaces .................................................. :
Yes No
17.4 (2.5) Luminaire for normal use ........................................ : Yes No
Luminaire for rough service ..................................... : Yes No
17.5 (3) MARKING P
17.5 (3.2) Mandatory markings The following are required and present:
3.2.1: origin (trademark, manu, etc)
3.2.2: rated voltage
3.2.3: Ta 50°C
3.2.6: IP23
3.2.7: model
3.2.8: rated wattage
3.2.9: suitable for mounting on normally flammable surfaces
3.2.13: minimum distance form lighting objects 7.5 m
3.2.16: Marked "Replace any cracked protective shield", or the symbol.
3.2.22: Fuse marking with current.
3.2.23: Marked
P
Position of the marking Markings are visible before and after installation
P
Format of symbols/text All symbols at least 5mm tall. Letters 2mm tall.
P
17.5 (3.3) Additional information See below P
Page 9 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
Language of instructions Instructions in language of target country
P
17.5 (3.3.1) Combination luminaires Not a combination luminaire N/A
17.5 (3.3.2) Nominal frequency in Hz 50 or 60 Hz P
17.5 (3.3.3) Operating temperature Temperatures marked P
17.5 (3.3.4) Symbol or warning notice Suitable for flammable surfaces N/A
17.5 (3.3.5) Wiring diagram Mains connected. N/A
17.5 (3.3.6) Special conditions None N/A
17.5 (3.3.7) Metal halide lamp luminaire – warning Marked as required P
17.5 (3.3.8) Limitation for semi-luminaires Not a semi luminaire N/A
17.5 (3.3.9) Power factor and supply current Information available from manufacturer.
P
17.5 (3.3.10)
Suitability for use indoors Suitable for use indoors or outdoors.
N/A
17.5 (3.3.11)
Luminaires with remote control No remote control gear. N/A
17.5 (3.3.12)
Clip-mounted luminaire – warning Not clip mounted. N/A
17.5 (3.3.13)
Specifications of protective shields Marked P
17.5 (3.3.14)
Symbol for nature of supply “~” provided. P
17.5 (3.3.15)
Rated current of socket outlet No socket outlets N/A
17.5 (3.3.16)
Rough service luminaire Not rough service N/A
17.5 (3.3.17)
Mounting instruction for type Y, type Z and some type X attachments
No cord. N/A
17.5 (3.3.18)
Non-ordinary luminaires with PVC cable No cord. N/A
17.5 (3.3.19)
Protective conductor current in instruction if applicable
Protective conductor current is less than 10mA
N/A
17.5 (3.3.20)
Provided with information if not intended to be mounted within arm’s reach
Not wall mounted or adjustable N/A
17.5 (3.3.21)
Non replaceable and non-user replaceable light sources information provided
Replaceable light source. N/A
Cautionary symbol Replaceable light source. N/A
17.5 (3.3.22)
Controllable luminaires, classification of insulation provided
Same insulation. P
17.5 (3.4) Test with water No adverse effects P
Page 10 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
Test with hexane No adverse effects P
Legible after test Yes P
Label attached Yes P
17.5.1 (-) If luminaire design imposes restriction of use the luminaire is marked with N/A
a) Indication of the “top” No design restriction. N/A
b) Designed position or range of angle No design restriction. N/A
c) Mounting arrangements No design restriction. N/A
17.5.2 (-) Warning if lamp ≤ 250W 1500W. N/A
17.5.3 (-) Maximum ambient temperature ta Marked with ambient temperature.
P
17.5.4 (-) Minimum distances from flammable materials Marked to keep flammable objects away.
P
17.5.5 (-) Warning against opening immediately if applicable Marked to wait for 5 minutes. P
17.5.6 (-) Value of exterior surface temperature P
a) after 5 min P
b) when steady state P
17.5.7 (-) Instruction leaflet contain warnings P
a) Visibly damaged shields shall be changed Marked. P
b) Damaged or thermally deformed lamp shall bechanged
Marked. P
17.6 (4) CONSTRUCTION P
17.6 (4.2) Components replaceable without difficulty Easily replaceable. P
17.6 (4.3) Wireways smooth and free from sharp edges Wireways are protected. P
17.6 (4.4) Lampholders P
17.6 (4.4.1) Integral lampholder Not integral. N/A
17.6 (4.4.2) Wiring connection No integral lampholder. N/A
17.6 (4.4.3) Lampholder for end-to-end mounting Not for end-to-end mounting N/A
17.6 (4.4.4) Positioning Not user positioned. N/A
- pressure test (N) ................................................... : Not user positioned. —
After test the lampholder comply with relevant standard sheets and show no damage
Not user positioned. N/A
After test on single-capped lampholder the lampholder have not moved from its position and show no permanent deformation
Not user positioned. N/A
- bending test (N) ..................................................... : Not user positioned. —
Page 11 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
After test the lampholder have not moved from its position and show no permanent deformation
Not user positioned. N/A
17.6 (4.4.5) Peak pulse voltage Peak voltage is <5kV. P
17.6 (4.4.6) Centre contact No centre contact. N/A
17.6 (4.4.7) Parts in rough service luminaires resistant to tracking Not for rough service. N/A
17.6 (4.4.8) Lamp connectors Suitable lamp connections. P
17.6 (4.4.9) Caps and bases correctly used Correctly used P
17.6 (4.4.10)
Light source for lampholder or connection according IEC 60061 not connected another way
Correctly used P
17.6 (4.5) Starter holders N/A
Starter holder in luminaires other than class II No starter. N/A
Starter holder class II construction No starter. N/A
17.6 (4.6) Terminal blocks N/A
Tails No tails provided for connection.
N/A
Unsecured blocks No unsecured blocks. N/A
17.6 (4.7) Terminals and supply connections P
17.6 (4.7.1) Contact to metal parts Connections made through and approved connector.
P
17.6 (4.7.2) Test 8 mm live conductor Connections made through and approved connector.
N/A
Test 8 mm earth conductor Connections made through and approved connector.
N/A
17.6 (4.7.3) Terminals for supply conductors Connections made through and approved connector.
P
17.6 (4.7.3.1)
Welded method and material N/A
- stranded or solid conductor No welding N/A
- spot welding No welding N/A
- welding between wires No welding N/A
- Type Z attachment No welding N/A
- mechanical test according to 15.6.2 No welding N/A
- electrical test according to 15.6.3 No welding N/A
- heat test according to 15.6.2.3 and 15.6.2.4 No welding N/A
17.6 (4.7.4) Terminals other than supply connection See sections 14/15 P
17.6 (4.7.5) Heat-resistant wiring/sleeves No external wiring. N/A
17.6 (4.7.6) Multi-pole plug Approved connector used. P
Page 12 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
- test at 30 N Approved connector used. N/A
17.6 (4.8) Switches P
- adequate rating No switches. N/A
- adequate fixing No switches. N/A
- polarized supply No switches. N/A
- compliance with IEC 61058-1 for electronic switches
No switches. N/A
17.6 (4.9) Insulating lining and sleeves P
17.6 (4.9.1) Retainment Secured in place. P
Method of fixing ........................................................ : Secured by shrink wrap. P
17.6 (4.9.2) Insulated linings and sleeves: P
Resistant to a temperature > 20 C to the wire temperature or
Rated for 616°C P
a) & c) Insulation resistance and electric strength Rated for 616°C P
b) Ageing test. Temperature (C) ............................. : Rated for 616°C N/A
17.6 (4.10) Double or reinforced insulation N/A
17.6 (4.10.1)
No contact, mounting surface – accessible metal parts – wiring of basic insulation
Class I N/A
Safe installation fixed luminaires Class I N/A
Capacitors and switches Class I N/A
Interference suppression capacitors according to IEC 60384-14
Class I N/A
17.6 (4.10.2)
Assembly gaps: N/A
- not coincidental Class I N/A
- no straight access with test probe Class I N/A
17.6 (4.10.3)
Retainment of insulation: N/A
- fixed Class I N/A
- unable to be replaced; luminaire inoperative Class I N/A
- sleeves retained in position Class I N/A
- lining in lampholder Class I N/A
17.6 (4.11) Electrical connections and current-carrying parts P
17.6 (4.11.1)
Contact pressure No pressure through insulation. P
17.6 (4.11.2)
Screws: N/A
Page 13 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
- self-tapping screws Machine screws used. N/A
- thread-cutting screws Machine screws used. N/A
17.6 (4.11.3)
Screw locking: N/A
- spring washer Screw connections are part of approved components.
N/A
- rivets No rivet electrical connections. N/A
17.6 (4.11.4)
Material of current-carrying parts Copper. P
17.6 (4.11.5)
No contact to wood or mounting surface No wood. P
17.6 (4.11.6)
Electro-mechanical contact systems No electrical mechanical contacts.
N/A
17.6 (4.12) Screws and connections (mechanical) and glands P
17.6 (4.12.1)
Screws not made of soft metal Stainless steel screws. P
Screws of insulating material No such screws. N/A
Torque test: torque (Nm); part .................................. : Thread measured 3.4mm Applied torque: 0.8Nm
P
17.6 (4.12.2)
Screws with diameter < 3 mm screwed into metal Screws into metal. P
17.6 (4.12.4)
Locked connections: N/A
- fixed arms; torque (Nm) ......................................... : No fixed arms. N/A
- lampholder; torque (Nm) ........................................ : No moving lampholder. N/A
- push-button switches; torque 0,8 Nm .................... : No switches. N/A
17.6 (4.12.5)
Screwed glands; force (Nm) ..................................... : No screwed glands. N/A
17.6 (4.13) Mechanical strength P
17.6 (4.13.1)
Impact tests: P
- fragile parts; energy (Nm) ...................................... : 0.2 Nm P
- other parts; energy (Nm) ........................................ : 0.35Nm P
1) live parts No damage P
2) linings No damage P
3) protection No damage P
4) covers No damage P
17.6 (4.13.3)
Straight test finger No live parts accessible P
Page 14 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
17.6 (4.13.4)
Rough service luminaires N/A
- IP54 or higher Not for rough service use. N/A
a) fixed Not for rough service use. N/A
b) hand-held Not for rough service use. N/A
c) delivered with a stand Not for rough service use. N/A
d) for temporary installations and suitable for mounting on a stand
Not for rough service use. N/A
17.6 (4.13.6)
Tumbling barrel No plug-ballast/transformers N/A
17.6 (4.14) Suspensions, fixings and means of adjusting P
17.6 (4.14.1)
Mechanical load: P
A) four times the weight Tested per 17.6.4 P
B) torque 2,5 Nm Tested per 17.6.4 P
C) bracket arm; bending moment (Nm).................... : Tested per 17.6.4 P
D) load track-mounted luminaires Not track mounted. N/A
E) clip-mounted luminaires, glass-shelve. Thickness (mm) ........................................................................ :
Not clip mounted. N/A
Metal rod. diameter (mm) ........................................ : Not clip mounted. N/A
Fixed luminaire or independent control gear without fixing devices
Not clip mounted. N/A
17.6 (4.14.2)
Load to flexible cables N/A
Mass (kg) ................................................................. : No flexible cord. —
Stress in conductors (N/mm²) ................................. : No flexible cord. N/A
Mass (kg) of semi-luminaire .................................... : No flexible cord. N/A
Bending moment (Nm) of semi-luminaire ................ : No flexible cord. N/A
17.6 (4.14.3)
Adjusting devices: P
- flexing test; number of cycles ................................. : >1500 P
- strands broken ....................................................... : None P
- electric strength test afterwards P
17.6 (4.14.4)
Telescopic tubes: cords not fixed to tube; no strain on conductors
No telescoping tubes. N/A
17.6 (4.14.5)
Guide pulleys No pulleys. N/A
Page 15 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
17.6 (4.14.6)
Strain on socket-outlets No outlets. N/A
17.6 (4.15) Flammable materials P
- glow-wire test 650C .............................................. : See Test Table 17.15 (13.3.2) N/A
- spacing 30 mm Spaced more than 30 mm. P
- screen withstanding test of 13.3.1 No screen. N/A
- screen dimensions No screen. N/A
- no fiercely burning material No such parts. P
- thermal protection Meets spacing requirements. N/A
- electronic circuits exempted Meets spacing requirements. N/A
17.6 (4.15.2)
Luminaires made of thermoplastic material with lamp control gear N/A
a) construction Metallic construction on controlgear.
N/A
b) temperature sensing control Metallic construction. N/A
c) surface temperature Metallic construction. N/A
17.6 (4.16) Luminaires for mounting on normally flammable surfaces P
No lamp control gear ................................................ : Has control gear. N/A
17.6 (4.16.1)
Lamp control gear spacing: P
- spacing 35 mm Spaced greater than 35 mm. P
- spacing 10 mm Meets spacing requirements. N/A
17.6 (4.16.2)
Thermal protection: N/A
- in lamp control gear Meets spacing requirement. N/A
- external Meets spacing requirement. N/A
- fixed position Meets spacing requirement. N/A
- temperature marked lamp control gear Meets spacing requirement. N/A
17.6 (4.16.3)
Design to satisfy the test of 12.6 Meets spacing requirement. N/A
17.6 (4.17) Drain holes P
Clearance at least 5 mm >5mm spacing. P
17.6 (4.18) Resistance to corrosion P
17.6 (4.18.1)
- rust-resistance Aluminum used for construction.
P
17.6 (4.18.2)
- season cracking in copper No such parts. N/A
Page 16 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
17.6 (4.18.3)
- corrosion of aluminium Resistant to corrosion. P
17.6 (4.19) Ignitors compatible with ballast Compatible. P
17.6 (4.20) Rough service vibration Not for rough service. N/A
17.6 (4.21) Protective shield P
17.6 (4.21.1)
Shield fitted if tungsten halogen lamps or metal halide lamps
Shield provided. P
Shield of glass if tungsten halogen lamps Metal halide type. N/A
17.6 (4.21.2)
Particles from a shattering lamp not impair safety Surrounds the lamp. P
17.6 (4.21.3)
No direct path No direct path. P
17.6 (4.21.4)
Impact test on shield No damage P
Glow-wire test on lamp compartment ....................... : Metallic and glass. N/A
17.6 (4.22) Attachments to lamps not cause overheating or damage
No attachments. N/A
17.6 (4.23) Semi-luminaires comply Class II Not a semi-luminaire. N/A
17.6 (4.24) Photobiological hazards P
17.6 (4.24.1)
No excessive UV radiation if tungsten halogen lamps and metal halide lamps (Annex P)
P
17.6 (4.24.2)
Retinal blue light hazard P
Luminaires with Ethr : P
a) Fixed luminaires P
- distance x m, borderline between RG1 and RG2 .. : 294 m P
- marking and instruction according 3.2.23 Marked P
b) Portable and handheld luminaires Fixed N/A
- marking according 3.2.23 if RG1 exceeded at 200 mm according to IEC/TR 62778
N/A
Portable luminaires for children IEC 60598-2-10 and Mains socket outlet nightlights IEC 60598-2-12 not exceed RG1 at 200 mm according to IEC/62778
N/A
17.6 (4.25) Mechanical hazard P
No sharp point or edges No sharp places. P
17.6 (4.26) Short-circuit protection P
17.6 (4.26.1)
Adequate means of uninsulated accessible SELV parts
SELV circuits are not accessible.
N/A
Page 17 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
17.6 (4.26.2)
Short-circuit test with test chain according 4.26.3 N/A
Test chain not melt through SELV circuits are not accessible.
N/A
Test sample not exceed values of Table 12.1 and 12.2
SELV circuits are not accessible.
N/A
17.6 (4.27) Terminal blocks with integrated screwless earthing contacts N/A
Test according Annex V No such terminal blocks. N/A
Pull test of terminal fixing (20 N) No such terminal blocks. N/A
After test, resistance < 0,05 No such terminal blocks. N/A
Pull test of mechanical connection (50 N) No such terminal blocks. N/A
After test, resistance < 0,05 No such terminal blocks. N/A
Voltage drop test, resistance < 0,05 No such terminal blocks. N/A
17.6 (4.28) Fixing of thermal sensing control N/A
Not plug-in or easily replaceable type No luminaire thermal sensing control.
N/A
Reliably kept in position No luminaire thermal sensing control.
N/A
No adhesive fixing if UV radiations from a lamp can degrade the fixing
No luminaire thermal sensing control.
N/A
Not outside the luminaire enclosure No luminaire thermal sensing control.
N/A
Test of adhesive fixing: N/A
Max. temperature on adhesive material (C) ........... : No luminaire thermal sensing control.
—
100 cycles between t min and t max No luminaire thermal sensing control.
N/A
Temperature sensing control still in position No luminaire thermal sensing control.
N/A
17.6 (4.29) Luminaires with non-replaceable light source N/A
Not possible to replace light source Lamp is replaceable. N/A
Live part not accessible after parts have been opened by hand or tools
Lamp is replaceable. N/A
17.6 (4.30) Luminaires with non-user replaceable light source N/A
If protective cover provide protection against electric shock and marked with “caution, electric shock risk” symbol:
N/A
Minimum two fixing means User replaceable. N/A
17.6 (4.31) Insulation between circuits P
Page 18 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
Circuits insulated from LV supply fulfil requirements according 4.31.1 – 4.31.3
See below. P
Controllable luminaires requiring same level of insulation for all components, the insulation between control terminals and LV supply fulfil requirements according 4.31.1 – 4.31.3
See below. P
17.6 (4.31.1)
SELV circuits P
Used SELV source SELV control gear used. P
Voltage ≤ ELV Voltage is 24VDC and 48VDC P
Insulating of SELV circuits from LV supply Insulation provided within the power supply.
P
Insulating of SELV circuits from other non SELV circuits
Insulation provided within the power supply.
P
Insulating of SELV circuits from FELV No FELV circuits N/A
Insulating of SELV circuits from other SELV circuits One SELV source. N/A
SELV circuits insulated from accessible parts according Table X.1
Insulated. P
Plugs not able to enter socket-outlets of other voltage systems
No plugs. N/A
Socket outlets does not admit plugs of other voltage systems
No outlets. N/A
Plugs and socket-outlets does not have protective conductor contact
No outlets. N/A
17.6 (4.31.2)
FELV circuits N/A
Used FELV source No FELV circuits. N/A
Voltage ≤ ELV No FELV circuits. N/A
Insulating of FELV circuits from LV supply No FELV circuits. N/A
FELV circuits insulated from accessible parts according Table X.1
No FELV circuits. N/A
Plugs not able to enter socket-outlets of other voltage systems
No FELV circuits. N/A
Socket outlets does not admit plugs of other voltage systems
No FELV circuits. N/A
Socket-outlets does not have protective conductor contact
No FELV circuits. N/A
17.6 (4.31.3)
Other circuits P
Page 19 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
Other circuits insulated from accessible parts according Table X.1
Insulated. P
Class II construction with equipotential bonding for protection against indirect contacts with live parts:
N/A
- conductive parts are connected together Class I. N/A
- test according 7.2.3 Class I. N/A
- conductive part not cause an electric shock in case of an insulation fault
Class I. N/A
- equipotential bonding in master/slave applications Class I. N/A
- master luminaire provided with terminal for accessible conductive parts of slave luminaires
Class I. N/A
- slave luminaire constructed as class I Class I. N/A
17.6 (4.32) Overvoltage protective devices N/A
Comply with IEC 61643-11 Part of approved controlgear. N/A
External to controlgear and connected to earth: N/A
- only in fixed luminaires Part of approved controlgear. N/A
- only connected to protective earth Part of approved controlgear. N/A
17.6.1 (-) Not possible to insert a lamp into a “live” lampholder if applicable
Exempt per amendment. N/A
17.6.2 (-) Prevent immediate access to the lamp or marked according 17.5.5 if applicable
Marked. P
17.6.3 (-) Fitted with a protective shield Shield provided P
Comply with test P
17.6.4 (-) Bearing parts of hanger are capable to support ten time the weight of the luminaire
670 lbs loaded. P
Non-combustible materials Metallic construction P
Parts of hanger carrying a proportion of the weight of the luminaire are capable to support ten time the proportion of weight
670 lbs loaded. P
Connection between hanger and luminaire locked Locked. P
17.6.5 (-) Removable accessories cannot fall out of the luminaire from any position
No removable accessories N/A
17.6.6 (-) If applicable a secondary suspension provided and passed the test
No hazard caused. P
17.7 (11) CREEPAGE DISTANCES AND CLEARANCES P
17.7 (11.2) Creepage distances and clearances ........................ : See Table 17.7 (11.2) P
Working voltage (V) .................................................. : 240V
Page 20 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
Rated pulse voltage (kV) .......................................... : < 5 kV
Voltage form ............................................................. : Sinusoidal
Non-sinusoidal
PTI ............................................................................ : < 600 > 600
Impulse withstand category (Normal category II) (Category III Annex U)
Category II Category III
17.8 (7) PROVISION FOR EARTHING P
17.8 (7.2.1 + 7.2.3)
Accessible metal parts Earthed. P
Metal parts in contact with supporting surface P
Resistance < 0,5 ................................................... : 0.05Ω P
Self-tapping screws used None. N/A
Thread-forming screws None. N/A
Thread-forming screw used in a grove None. N/A
Earth makes contact first Approved connector that makes earthing connection first.
P
Terminal blocks with integrated screwless earthing contacts tested according Annex V
None. N/A
Protective earthing of the luminaire not via built-in control gear
P
17.8 (7.2.2 + 7.2.3)
Earth continuity in joints, etc. Continuity maintained. P
17.8 (7.2.4) Locking of clamping means Star washer used. P
Compliance with 4.7.3 See clause. P
Terminal blocks with integrated screwless earthing contacts tested according Annex V
Approved connectors. P
17.8 (7.2.5) Earth terminal integral part of connector socket Integral. P
17.8 (7.2.6) Earth terminal adjacent to mains terminals Part of the input connector. P
17.8 (7.2.7) Electrolytic corrosion of the earth terminal Similar metals. P
17.8 (7.2.8) Material of earth terminal Stainless steel type. P
Contact surface bare metal Bare P
17.8 (7.2.10)
Class II luminaire for looping-in Class I. N/A
Double or reinforced insulation to functional earth Class I. N/A
17.8 (7.2.11)
Earthing core coloured green-yellow Green-yellow. P
Page 21 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
Length of earth conductor Connector used for input. N/A
17.9 (14) SCREW TERMINALS P
Separately approved; component list see Annex 1 P
Part of the luminaire Approved component. N/A
17.9 (15) SCREWLESS TERMINALS AND ELECTRICAL CONNECTIONS P
Separately approved; component list ....................... : see Annex 1 P
Part of the luminaire ................................................. : Approved component. N/A
17.10 (5) EXTERNAL AND INTERNAL WIRING P
17.10 (5.2) Supply connection and external wiring P
17.10 (5.2.1)
Means of connection ................................................ : Appliance inlet. P
Outdoor luminaire has not PVC insulated external wiring if not class III or SELV ≤ 25 V a.c./60 V d.c. or protected from outdoor environment
No cord. N/A
17.10 (5.2.2)
Type of cable ............................................................ : No cord. N/A
Nominal cross-sectional area (mm²) ........................ : No cord. N/A
Cables equal to IEC 60227 or IEC 60245 No cord. N/A
17.10 (5.2.3)
Type of attachment, X, Y or Z No cord. N/A
17.10 (5.2.5)
Type Z not connected to screws No cord. N/A
17.10 (5.2.6)
Cable entries: N/A
- suitable for introduction No cable entries. N/A
- adequate degree of protection No cable entries. N/A
17.10 (5.2.7)
Cable entries through rigid material have rounded edges
No cable entries. N/A
17.10 (5.2.8)
Insulating bushings: N/A
- suitably fixed No cables through the luminaire.
N/A
- material in bushings No cables through the luminaire.
N/A
Page 22 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
- material not likely to deteriorate No cables through the luminaire.
N/A
- tubes or guards made of insulating material No cables through the luminaire.
N/A
17.10 (5.2.9)
Locking of screwed bushings None. N/A
17.10 (5.2.10)
Cord anchorage: N/A
- covering protected from abrasion No cord. N/A
- clear how to be effective No cord. N/A
- no mechanical or thermal stress No cord. N/A
- no tying of cables into knots etc. No cord. N/A
- insulating material or lining No cord. N/A
17.10 (5.2.10.1)
Cord anchorage for type X attachment: N/A
a) at least one part fixed No cord. N/A
b) types of cable No cord. N/A
c) no damaging of the cable No cord. N/A
d) whole cable can be mounted No cord. N/A
e) no touching of clamping screws No cord. N/A
f) metal screw not directly on cable No cord. N/A
g) replacement without special tool No cord. N/A
Glands not used as anchorage No cord. N/A
Labyrinth type anchorages No cord. N/A
17.10 (5.2.10.2)
Adequate cord anchorage for type Y and type Z attachment
No cord. N/A
17.10 (5.2.10.3)
Tests: N/A
- impossible to push cable; unsafe No cord. N/A
- pull test: 25 times; pull (N) ..................................... : No cord. N/A
- torque test: torque (Nm) ......................................... : No cord. N/A
- displacement 2 mm No cord. N/A
- no movement of conductors No cord. N/A
- no damage of cable or cord No cord. N/A
- function independent of electrical connection No cord. N/A
17.10 (5.2.11)
External wiring passing into luminaire No wires through luminaire. N/A
Page 23 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
17.10 (5.2.12)
Looping-in terminals No loop in terminals. N/A
17.10 (5.2.13)
Wire ends not tinned Wires not tinned. P
Wire ends tinned: no cold flow Wires not tinned. N/A
17.10 (5.2.14)
Mains plug same protection No plug. N/A
Class III luminaire plug Class I. N/A
No unsafe compatibility Class I. N/A
17.10 (5.2.16)
Appliance inlets (IEC 60320) Approved to IEC 60320. P.
Installation couplers (IEC 61535) Approved to IEC 60320. N/A
Other appliance inlet or connector according relevant IEC standard
Approved to IEC 60320. N/A
17.10 (5.2.17)
No standardized interconnecting cables properly assembled
No interconnecting cable. N/A
17.10 (5.2.18)
Used plug in accordance with N/A
- IEC 60083 No such plugs. N/A
- other standard No such plugs. N/A
17.10 (5.3) Internal wiring P
17.10 (5.3.1)
Internal wiring of suitable size and type Suitable wiring used. P
Through wiring N/A
- not delivered/ mounting instruction No through wiring. N/A
- factory assembled No through wiring. N/A
- socket outlet loaded (A) ......................................... : No through wiring. N/A
- temperatures .......................................................... : No through wiring. N/A
Green-yellow for earth only No through wiring. N/A
17.10 (5.3.1.1)
Internal wiring connected directly to fixed wiring P
Cross-sectional area (mm²) ...................................... : 2.03mm² P
Insulation thickness 0.76 mm P
Extra insulation added where necessary None. N/A
17.10 (5.3.1.2)
Internal wiring connected to fixed wiring via internal current-limiting device P
Adequate cross-sectional area and insulation thickness
Meets above requirements. N/A
Page 24 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
17.10 (5.3.1.3)
Double or reinforced insulation for class II Class I N/A
17.10 (5.3.1.4)
Conductors without insulation None. N/A
17.10 (5.3.1.5)
SELV current-carrying parts Insulated conductors. N/A
17.10 (5.3.1.6)
Insulation thickness other than PVC or rubber Insulation meets thickness requirements.
N/A
17.10 (5.3.2)
Sharp edges etc. No sharp edges. P
No moving parts of switches etc. No switches. N/A
Joints, raising/lowering devices No damage. P
Telescopic tubes etc. No tubes. N/A
No twisting over 360 No cables twisted. N/A
17.10 (5.3.3)
Insulating bushings: P
- suitable fixed Snaps in place P
- material in bushings Polymeric P
- material not likely to deteriorate P
- cables with protective sheath Sheath also used. P
17.10 (5.3.4)
Joints and junctions effectively insulated Insulated. P
17.10 (5.3.5)
Strain on internal wiring No external wires. N/A
17.10 (5.3.6)
Wire carriers None. N/A
17.10 (5.3.7)
Wire ends not tinned Not tinned N/A
Wire ends tinned: no cold flow Not tinned N/A
17.10.1 (-) Cross-sectional area (mm²)
≥ 0,75 for current ≤ 2A and ≥ 1,5 for current > 2A
2.08 mm² P
17.10.2 (-) Plugs and sockets not interchangeable Not interchangeable. P
17.11 (8) PROTECTION AGAINST ELECTRIC SHOCK P
17.11 (8.2.1)
Live parts not accessible Not accessible. P
Basic insulated parts not used on the outer surface without appropriate protection
Not accessible P
Page 25 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
Basic insulated parts not accessible with standard test finger on portable, settable and adjustable luminaires
Not accessible P
Basic insulated parts not accessible with Ø 50 mm probe from outside, other types of luminaires
Not accessible P
Lamp and starterholders in portable and adjustable luminaires comply with double or reinforced insulation requirements
Meets requirement. P
Basic insulation only accessible under lamp or starter replacement
P
Protection in any position P
Double-ended tungsten filament lamp Metal Halide type. N/A
Insulation lacquer not reliable No lacquer. N/A
Double-ended high pressure discharge lamp Single ended. N/A
Relevant warning according to 3.2.18 fitted to the luminaire
Single ended. N/A
17.11 (8.2.2)
Portable luminaire adjusted in most unfavourable position
Checked in most unfavourable position.
P
17.11 (8.2.3.a)
Class II luminaire: N/A
- basic insulated metal parts not accessible during starter or lamp replacement
Class I. N/A
- basic insulation not accessible other than during starter or lamp replacement
Class I. N/A
- glass protective shields not used as supplementary insulation
Class I. N/A
17.11 (8.2.3.b)
BC lampholder of metal in class I luminaires shall be earthed
Not metal. N/A
17.11 (8.2.3.c)
SELV circuits with exposed current carrying parts: N/A
Ordinary luminaire: N/A
- touch current ......................................................... : Not exposed N/A
- no-load voltage ....................................................... : Not exposed N/A
Other than ordinary luminaire: N/A
- nominal voltage ..................................................... : Not exposed N/A
17.11 (8.2.4)
Portable luminaire have protection independent of supporting surface
Approved connector used. P
17.11 (8.2.5)
Compliance with the standard test finger or relevant probe
P
Page 26 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
17.11 (8.2.6)
Covers reliably secured Secured by screws. P
17.11 (8.2.7)
Discharging of capacitors 0,5 F Voltage was below the 1V within 1 second
P
Portable plug connected luminaire with capacitor P
Other plug connected luminaire with capacitor P
Discharge device on or within capacitor P
Discharge device mounted separately P
17.11.1 (-) Luminaires exempt from 17.6.1 requirements for protection against contact with live parts after opening does not apply
Not exempt from 17.6.1
17.12 (12) ENDURANCE TEST AND THERMAL TEST P
17.12 (12.3)
Endurance test: P
- mounting-position ................................................... : Hanging
- test temperature (C) ............................................. : 60
- total duration (h) ..................................................... : 240
- supply voltage: Un factor; calculated voltage (V) ... : 254
- lamp used ............................................................... : Philips MSR Gold 1500
17.12 (12.3.2)
After endurance test: P
- no part unserviceable No parts unserviceable P
- luminaire not unsafe Luminaire is not unsafe P
- no damage to track system No damage P
- marking legible Marking legible P
- no cracks, deformation etc. No damage P
17.12 (12.4)
Thermal test (normal operation) see Annex 2 P
17.12 (12.5)
Thermal test (abnormal operation) No abnormal conditions. N/A
17.12 (12.6)
Thermal test (failed lamp control gear condition): N/A
17.12 (12.6.1)
Through wiring or looping-in wiring loaded by a current of (A) ........................................................... :
Meets the requirements of 4.16.1
- case of abnormal conditions .................................. : Meets the requirements of 4.16.1
Page 27 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
- electronic lamp control gear Meets the requirements of 4.16.1
N/A
- measured winding temperature (C): at 1,1 Un .... : Meets the requirements of 4.16.1
- measured mounting surface temperature (C) at 1,1 Un ....................................................................... :
Meets the requirements of 4.16.1
N/A
- calculated mounting surface temperature (C) ..... : Meets the requirements of 4.16.1
N/A
- track-mounted luminaires Not track mounted. N/A
17.12 (12.6.2)
Temperature sensing control N/A
- case of abnormal conditions .................................. : Meets the requirements of 4.16.1
- thermal link Meets the requirements of 4.16.1
N/A
- manual reset cut-out Meets the requirements of 4.16.1
N/A
- auto reset cut-out Meets the requirements of 4.16.1
N/A
- measured mounting surface temperature (C) ...... : Meets the requirements of 4.16.1
N/A
- track-mounted luminaires Not track mounted. N/A
17.12 (12.7)
Thermal test (failed lamp control gear in plastic luminaires): N/A
17.12 (12.7.1)
Luminaire without temperature sensing control N/A
17.12 (12.7.1.1)
Luminaire with fluorescent lamp ≤ 70W N/A
Test method 12.7.1.1 or Annex W .......................... : Not a fluorescent luminaire.
Test according to 12.7.1.1: N/A
- case of abnormal conditions .................................. : Fitted with temperature-independent support.
- Ballast failure at supply voltage (V) ....................... : Fitted with temperature-independent support.
- Components retained in place after the test Fitted with temperature-independent support.
N/A
- Test with standard test finger after the test Fitted with temperature-independent support.
N/A
Test according to Annex W: N/A
- case of abnormal conditions .................................. : Fitted with temperature-independent support.
- measured winding temperature (C): at 1,1 Un ..... : Fitted with temperature-independent support.
Page 28 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
- measured temperature of fixing point/exposed part
(C): at 1,1 Un .......................................................... :
Fitted with temperature-independent support.
- calculated temperature of fixing point/exposed part
(C) ........................................................................... :
Fitted with temperature-independent support.
Ball-pressure test .................................................. : Fitted with temperature-independent support.
N/A
17.12 (12.7.1.2)
Luminaire with discharge lamp, fluorescent lamp > 70W, transformer > 10 VA N/A
- case of abnormal conditions .................................. : Fitted with temperature-independent support.
- measured winding temperature (C): at 1,1 Un ..... : Fitted with temperature-independent support.
- measured temperature of fixing point/exposed part
(C): at 1,1 Un .......................................................... :
Fitted with temperature-independent support.
- calculated temperature of fixing point/exposed part
(C) ........................................................................... :
Fitted with temperature-independent support.
Ball-pressure test ..................................................... : Fitted with temperature-independent support.
N/A
17.12 (12.7.1.3)
Luminaire with short circuit proof transformers ≤ 10 VA
Fitted with temperature-independent support.
N/A
- case of abnormal conditions .................................. : Fitted with temperature-independent support.
- Components retained in place after the test Fitted with temperature-independent support.
N/A
- Test with standard test finger after the test Fitted with temperature-independent support.
N/A
17.12 (12.7.2)
Luminaire with temperature sensing control N/A
- thermal link ............................................................. : Yes No
- manual reset cut-out .............................................. : Yes No
- auto reset cut-out ................................................... : Yes No
- case of abnormal conditions .................................. : Fitted with temperature-independent support.
- highest measured temperature of fixing point/
exposed part (C): .................................................... :
Fitted with temperature-independent support.
Ball-pressure test: .................................................... : Fitted with temperature-independent support.
N/A
17.12.1 (-) Exterior surface temperature see Annex 2 P
17.13 (9) RESISTANCE TO DUST AND MOISTURE P
17.13 (9.2) Tests for ingress of dust, solid objects and moisture: P
- classification according to IP .................................. : IP 23
- mounting position during test ................................. : Tested standing upright.
Page 29 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
- fixing screws tightened; torque (Nm) ..................... : No fixing screws.
- tests according to clauses ...................................... : 9.2 f, 9.2.4
- electric strength test afterwards P
a) no deposit in dust-proof luminaire N/A
b) no talcum in dust-tight luminaire N/A
c) no trace of water on current-carrying parts or on insulation where it could become a hazard
No water contact on live parts P
d) i) For luminaires without drain holes – no water entry
Drain holes provided. N/A
d) ii) For luminaires with drain holes – no hazardous water entry
No hazardous water contact. P
e) no water in watertight luminaire Not water tight. N/A
f) no contact with live parts (IP 2X) No contact with live parts P
f) no entry into enclosure (IP 3X and IP 4X) N/A
f) no contact with live parts (IP3X and IP4X) N/A
g) no trace of water on part of lamp requiring protection from splashing water
No water P
h) no damage of protective shield or glass envelope No damage P
17.13 (9.3) Humidity test 48 h P
17.14 (10) INSULATION RESISTANCE AND ELECTRIC STRENGTH P
17.14 (10.2.1)
Insulation resistance test P
Cable or cord covered by metal foil or replaced by a metal rod of mm Ø ................................................... :
No cord.
Insulation resistance (M) ....................................... : >10GΩ @ 500V
SELV P
- between current-carrying parts of different polarity : >10GΩ @ 100V P
- between current-carrying parts and mounting surface ...................................................................... : >10GΩ @ 100V
P
- between current-carrying parts and metal parts of the luminaire ............................................................. : >10GΩ @ 100V
P
- between the outer surface of a flexible cord or cable where it is clamped in a cord anchorage and accessible metal parts .............................................. : No cord
N/A
- Insulation bushings as described in Section 5 ...... : >10GΩ @ 500V P
Other than SELV P
Page 30 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
- between live parts of different polarity ................... : >10GΩ @ 500V P
- between live parts and mounting surface .............. : >10GΩ @ 500V P
- between live parts and metal parts ........................ : >10GΩ @ 500V P
- between live parts of different polarity through action of a switch ...................................................... : No switch
N/A
- between the outer surface of a flexible cord or cable where it is clamped in a cord anchorage and accessible metal parts .............................................. : No cord
N/A
- Insulation bushings as described in Section 5 ...... : >10GΩ @ 500V P
17.14 (10.2.2)
Electric strength test
Dummy lamp P
Luminaires with ignitors after 24 h test P
Luminaires with manual ignitors No manual ignitor N/A
Test voltage (V) ........................................................ : 1480Vac 60hz P
SELV
- between current-carrying parts of different polarity : Dielectric voltage: 500Vdc Leakage: 0.1 uA
P
- between current-carrying parts and mounting surface ...................................................................... :
Dielectric voltage: 500Vdc Leakage: 0.1 uA
P
- between current-carrying parts and metal parts of the luminaire ............................................................. :
Dielectric voltage: 500Vdc Leakage: 0.1 uA
P
- between the outer surface of a flexible cord or cable where it is clamped in a cord anchorage and accessible metal parts .............................................. :
Dielectric voltage: 500Vdc Leakage: 0.1 uA
P
- Insulation bushings as described in Section 5 ...... : Dielectric voltage: 500Vdc Leakage: 0.1 uA
P
Other than SELV
- between live parts of different polarity ................... : Dielectric voltage: 1480Vac Leakage: 4.0 mA
P
- between live parts and mounting surface .............. : Dielectric voltage: 1480Vac Leakage: 4.0 mA
P
- between live parts and metal parts ........................ : Dielectric voltage: 1480Vac Leakage: 4.0 mA
P
- between live parts of different polarity through action of a switch ...................................................... :
N/A
- between the outer surface of a flexible cord or cable where it is clamped in a cord anchorage and accessible metal parts .............................................. :
Dielectric voltage: 1480Vac Leakage: 4.0 mA
P
- Insulation bushings as described in Section 5 ...... : Dielectric voltage: 1480Vac Leakage: 4.0 mA
P
7.14 (10.3) Touch current or protective conductor current (mA) : 0.68 mA P
Page 31 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
17.15 (13) RESISTANCE TO HEAT, FIRE AND TRACKING N/A
17.15 (13.2.1)
Ball-pressure test ..................................................... : Polymeric is spaced away. N/A
17.15 (13.3.1)
Needle-flame test (10 s) ........................................... : N/A
17.15 (13.3.2)
Glow-wire test (650C) ............................................. : N/A
17.15 (13.4)
Proof tracking test (IEC 60112) ................................ : N/A
Page 32 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
17.7 (11.2) TABLES: Creepage distances and clearances
Table 11.1 Minimum distances (mm) for a.c. (50/60 Hz) sinusoidal voltages
RMS working voltage (V) not exceeding 50 150 250 500 750 1000
Creepage distances
Required basic insulation, PTI 600 0,6 0,8 1,5 3 4 5,5
Measured
Required basic insulation, PTI < 600 1,2 1,6 2,5 5 8 10
Measured
Required supplementary insulation PTI 600 - 0,8 1,5 3 4 5,5
Measured
Required supplementary insulation PTI < 600 - 1,6 2,5 5 8 10
Measured
Required reinforced insulation - 3,2 5 6 8 11
Measured
Clearances
Required basic insulation 0,2 0,8 1,5 3 4 5,5
Measured
Required supplementary insulation - 0,8 1,5 3 4 5,5
Measured
Required reinforced insulation - 1,6 3 6 8 11
Measured
Table 11.2 Minimum distances (mm) for non-sinusoidal pulse voltages
Rated pulse voltage (peak kV) 2,0 2,5 3,0 4,0 5,0 6,0 8,0
Required clearances 1,0 1,5 2 3 4 5,5 8
Measured
Rated pulse voltage (peak kV) 10 12 15 20 25 30 40
Required clearances 11 14 18 25 33 40 60
Measured
Rated pulse voltage (peak kV) 50 60 80 100 - - -
Required clearances 75 90 130 170 - - -
Measured
Page 33 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
17.15 (13.2.1)
TABLE: Ball Pressure Test of Thermoplastics
Allowed impression diameter (mm) .................... :
Object/ Part No./ Material Manufacturer/ trademark
Test temperature (C) Impression diameter (mm)
Supplementary information:
17.15 (13.3.1)
TABLE: Needle-flame test (IEC 60695-11-5)
Object/ Part No./ Material
Manufacturer/ trademark
Duration of application of test
flame (ta); (s)
Ignition of specified layer
Yes/No
Duration of burning (tb)
(s) Verdict
Supplementary information:
17.15 (13.3.2)
TABLE: Glow-wire test (IEC 60695-2-11)
Glow wire temperature ......................................... : 650°C
Object/ Part No./ Material
Manufacturer/ trademark
Ignition of specified layer
Yes/No
Duration of burning (tb)
(s) Verdict
Any flame or glowing of the sample extinguished within 30 s of withdrawing the glow-wire, and any burning or molten drop did not ignite the underlying parts (Yes/No) ...................................... :
Supplementary information:
Page 34 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
17.15 (13.4)
TABLE: Proof tracking test (IEC 60112)
Test voltage PTI .................................................... : 175 V
Object/ Part No./ Material Manufacturer/ trademark
Withstand 50 drops without failure on three places or on three specimens
Verdict
Supplementary information:
Page 35 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
ANNEX 1 TABLE: Critical components information P
Object / part No.
Code Manufacturer/ trademark
Type / model Technical data Standard Mark(s) of conformity
1)
Enclosure A Sabic Innovative Plastics
EFX830ME
Polymeric, Minimum 2.15
mm thick, 90°C,
Flame Rating: 5VA
IEC 60598-2-17:1984+A1:1987+A2:1990
Evaluated per
requirements
Lens A Various Various Glass, 2.75mm thick
IEC 60598-2-17:1984+A1:1987+A2:1990
Evaluated per
requirements
Centrifugal Fans A YS Tech USA BW09733012BH
12VDC, 0.74A, Polymeric, V-0, 32.4 CFM, 3800 RPM
UL 507 cURus
Crossflow Fan A Y.S. Tech CFS09825012BH
7.2CFM, 12VDC, 0.13A
UL 507 cURus
Lamp Enclosure A Various Various Aluminum, 2mm thick, 150x150x160mm
IEC 60598-2-17:1984+A1:1987+A2:1990
Evaluated per
requirements
Ballast B CCI Power Supplies
SBC1500
55°C
Input: 208-240VAC, 50/60Hz, 8.48A Output: 100VAC, 15A
EN61347-2-12
CE
Lampholder B Bender & Wirth GMBH & CO
PGJX50
250V, 30A,
Max °350,
Ignition voltage: 5kV
IEC 60598-2-17:1984+A1:1987+A2:1990
Evaluated per
requirements
Filter Philips Entertainment
416189RC
Evaluated under Intertek report 101422452DAL-001.
IEC 60598-2-17:1984+A1:1987+A2:1990
Evaluated per
requirements
Bulb A Various Various 950°C, 198V,
Metal Halide, 1500W
IEC 60598-2-17:1984+A1:1987+A2:1990
Evaluated per
requirements
Power Supply B CCI Power Supplies
LM200P
Input: 100-277VAC, 50/60Hz, 2.6A Output: 24, 48VDC, 8.3A Max
EN60950 CE
Label B Various Various
80°C minimum
temperature, suitable for adhesion to the surface it is applied to.
IEC 60598-2-17:1984+A1:1987+A2:1990
Evaluated per
requirements
Page 36 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
Lamp Containment Barrier
A Various Various Glass, 2.75mm thick
IEC 60598-2-17:1984+A1:1987+A2:1990
Evaluated per
requirements
PCB, Ignitor A ALLIED PCB. LLC
11-9704-1126 REV B
V-0, Max 90°C
IEC 60598-2-17:1984+A1:1987+A2:1990 UL 94
Evaluated per
requirements
cURus
PWB, Ignitor A Philips VL4000 Ignitor Board
Uses PCB, Ignitor IEC 60598-2-17:1984+A1:1987+A2:1990
Evaluated per
requirements
Coil, Ignitor C NOVA MAGNETICS
68.9704.1127
Ferrite Rod core, 14AWG wiring, Insulation Class B
IEC 60598-2-17:1984+A1:1987+A2:1990
Evaluated per
requirements
Resistors, Ignitor (x 2)
A Xicon Passive Components
286-30K-RC
Ceramic core, 235°C, 30kΩ, 5W, Metal Oxide Axial
IEC 60598-2-17:1984+A1:1987+A2:1990
Evaluated per
requirements
Supplementary information: 1)
Provided evidence ensures the agreed level of compliance. See OD-CB2039.
The codes above have the following meaning:
A - The component is replaceable with another one, also certified, with equivalent characteristics
B - The component is replaceable if authorised by the test house
C - Integrated component tested together with the appliance
D - Alternative component
Page 37 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
ANNEX 2 TABLE: Temperature measurements, thermal tests of Section 12 P
Type reference ....................................................... : VL 6000 Luminaire
Lamp used .............................................................. : Philips MSR Gold 1500
Lamp control gear used .......................................... : CCI Power Supplies SBC1500
Mounting position of luminaire ............................... : Upright
Supply wattage (W) ................................................ : 1700W
Supply current (A) .................................................. : 7.4
Calculated power factor .......................................... : 0.93
Table: measured temperatures corrected for ta = 50 C: P
- abnormal operating mode .................................... : N/A
- test 1: rated voltage .............................................. : N/A
- test 2: 1,06 times rated voltage or 1,05 times rated wattage ................................................................... :
254V
- test 3: Load on wiring to socket-outlet, 1,06 times voltage or 1,05 times wattage ................................ :
N/A
- test 4: 1,1 times rated voltage or 1,05 times rated wattage ................................................................... :
N/A
Through wiring or looping-in wiring loaded by a current of A during the test .................................... :
N/A
Temperature measurements, (C)
Part Ambient Clause 12.4 – normal Clause 12.5 – abnormal
test 1 test 2 test 3 limit test 4 limit
Wires to lampholder
50 162.6 163.1 N/A 200 N/A N/A
Ignitor 50 96.7 97.6 N/A 105 N/A N/A
Cooling fan 50 106.6 107 N/A 120 N/A N/A
Cutter cooling fan
50 72.9 75.6 N/A 85 N/A N/A
Filter cap 50 84.9 84.4 N/A 105 N/A N/A
Ballast 50 78.8 79.6 N/A 90 N/A N/A
DC power supply
50 63.0 60.8 N/A 90 N/A N/A
Input connection 50 79.2 79.6 N/A 90 N/A N/A
Filter transformer
50 98.6 95.2 N/A 120 N/A N/A
Lampholder 50 151.6 152 N/A 200 N/A N/A
Page 38 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
Input wire 50 84.2 84 N/A 105 N/A N/A
Tilt motor 50 74.3 75.1 N/A 90 N/A N/A
Gasket near lamp
50 91.1 91.6 N/A 200 N/A N/A
Filter coil 50 92.8 90.6 N/A 120 N/A N/A
Power dist. Board
50 94.7 94.7 N/A 130 N/A N/A
Terminal block 50 69.4 70.4 N/A 105 N/A N/A
Enclosure 50 90.2 91.2 N/A 90 N/A N/A
DC connectors 50 71.2 72.4 N/A 90 N/A N/A
Supplementary information:
Page 39 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
ANNEX 3 Screw terminals (part of the luminaire) N/A
(14) SCREW TERMINALS N/A
(14.2) Type of terminal ........................................................ : Approved terminals used.
Rated current (A) ...................................................... :
(14.3.2.1) One or more conductors N/A
(14.3.2.2) Special preparation N/A
(14.3.2.3) Terminal size N/A
Cross-sectional area (mm²) ...................................... :
(14.3.3) Conductor space (mm) ............................................. : N/A
(14.4) Mechanical tests N/A
(14.4.1) Minimum distance N/A
(14.4.2) Cannot slip out N/A
(14.4.3) Special preparation N/A
(14.4.4) Nominal diameter of thread (metric ISO thread) ...... : M N/A
External wiring N/A
No soft metal N/A
(14.4.5) Corrosion N/A
(14.4.6) Nominal diameter of thread (mm) ............................ : N/A
Torque (Nm) ............................................................. : N/A
(14.4.7) Between metal surfaces N/A
Lug terminal N/A
Mantle terminal N/A
Pull test; pull (N) ....................................................... : N/A
(14.4.8) Without undue damage N/A
Page 40 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
ANNEX 4 Screwless terminals (part of the luminaire) N/A
(15) SCREWLESS TERMINALS N/A
(15.2) Type of terminal ........................................................ : Approved component.
Rated current (A) ...................................................... :
(15.3.1) Material N/A
(15.3.2) Clamping N/A
(15.3.3) Stop N/A
(15.3.4) Unprepared conductors N/A
(15.3.5) Pressure on insulating material N/A
(15.3.6) Clear connection method N/A
(15.3.7) Clamping independently N/A
(15.3.8) Fixed in position N/A
(15.3.10) Conductor size N/A
Type of conductor N/A
(15.5) Terminals and connections for internal wiring N/A
(15.5.1) Mechanical tests N/A
(15.5.1.1.1) Pull test spring-type terminals (4 N, 4 samples) ...... : N/A
(15.5.1.1.2) Pull test pin or tab terminals (4 N, 4 samples) ......... : N/A
Insertion force not exceeding 50 N N/A
(15.5.1.2) Permanent connections: pull-off test (20 N) N/A
(15.5.2) Electrical tests
Voltage drop (mV) after 1 h (4 samples) .................. : N/A
Voltage drop of two inseparable joints N/A
Number of cycles:
Voltage drop (mV) after 10th alt. 25th cycle (4 samples) ............................................................... :
N/A
Voltage drop (mV) after 50th alt. 100th cycle (4 samples) ............................................................... :
N/A
After ageing, voltage drop (mV) after 10th alt. 25th cycle (4 samples) ............................................. :
N/A
After ageing, voltage drop (mV) after 50th alt. 100th cycle (4 samples) ........................................... :
N/A
(15.6) Terminals and connections for external wiring N/A
(15.6.1) Conductors N/A
Page 41 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
Terminal size and rating N/A
15.6.2 Mechanical tests N/A
(15.6.2.1) Pull test spring-type terminals or welded connections (4 samples); pull (N) ................................................ :
N/A
(15.6.2.2) Pull test pin or tab terminals (4 samples); pull (N) ..................................................................... :
N/A
(15.6.3) Electrical tests N/A
Tests according 15.6.3.1 + 15.6.3.2 in IEC 60598-1 N/A
(15.6.3.1)
(15.6.3.2) TABLE: Contact resistance test / Heating tests
Voltage drop (mV) after 1 h
terminal 1 2 3 4 5 6 7 8 9 10
voltage drop (mV)
Voltage drop of two inseparable joints
Voltage drop after 10th alt. 25th cycle
Max. allowed voltage drop (mV) ................ :
terminal 1 2 3 4 5 6 7 8 9 10
voltage drop (mV)
Voltage drop after 50th alt. 100th cycle
Max. allowed voltage drop (mV) ................ :
terminal 1 2 3 4 5 6 7 8 9 10
voltage drop (mV)
Continued ageing: voltage drop after 10th alt. 25th cycle
Max. allowed voltage drop (mV) ................ :
terminal 1 2 3 4 5 6 7 8 9 10
voltage drop (mV)
Continued ageing: voltage drop after 50th alt. 100th cycle
Max. allowed voltage drop (mV) ................ :
terminal 1 2 3 4 5 6 7 8 9 10
voltage drop (mV)
Supplementary information:
Page 42 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
ATTACHMENT TO TEST REPORT IEC 60598-2-17 EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES
LUMINAIRES PART 2: PARTICULAR REQUIREMENTS:
SECTION SEVENTEEN - LUMINAIRES FOR STAGE LIGHTING, TELEVISION AND FILM STUDIOS (OUTDOOR AND INDOOR)
Differences according .................... : EN 60598-2-17:1989 + A2:1991 used in conjunction with EN 60598-1:2008 + A11:2009
Annex Form No. .............................. : EU_GD_IEC60598_2_17C
Annex Form Originator ..................... : IMQ S.p.A.
Master Annex Form .......................... : 2010-08
Copyright © 2010 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved.
CENELEC COMMON MODIFICATIONS (EN) P
17.5 (3) MARKING N/A
17.5 (3.3.101)
Adequate warning on the package No terminal blocks N/A
17.6 (4) CONSTRUCTION N/A
17.6 (4.11.6) Electro-mechanical contact systems No electrical mechanical contact systems
N/A
17.10 (5) EXTERNAL AND INTERNAL WIRING P
17.10 (5.2.1) Connecting leads Luminaire supplied with appliance inlet.
P
- without a means for connection to the supply Luminaire supplied with appliance inlet.
N/A
- terminal block specified No terminal block for connecting leads
N/A
- relevant information provided Relevant information is provided
N/A
- compliance with 4.6, 4.7.1, 4.7.2, 4.10.1, 11.2, 12 and 13.2 of Part 1
Terminal block is not used for supply connections
N/A
17.10 (5.2.2) Cables equal to HD21 S2 or HD22 S2 No cable. N/A
17.12 (12) ENDURANCE TEST AND THERMAL TEST N/A
17.12 (12.4.2c)
Thermal test (normal operation) see footnote c to table 12.2 relating to unsleeved fixed wiring
All installations supplied with luminaire
N/A
Page 43 of 47 Report No. 102761244DAL-002
IEC 60598-2-17
Clause Requirement + Test Result - Remark Verdict
TRF No. IEC60598_2_17D
ZB ANNEX ZB, SPECIAL NATIONAL CONDITIONS (EN) P
(3.3) DK: power supply cord with label Present P
IT: warning label on Class 0 luminaire Not a class 0 luminaire N/A
(4.5.1) DK: socket-outlets No socket outlets N/A
(5.2.1) CY, DK, FI, SE, GB: type of plug No plug included N/A
ZC ANNEX ZC, NATIONAL DEVIATIONS (EN) N/A
(4 & 5) FR: Shuttered socket-outlets 10/16A No outlets of the type referenced used.
N/A
(13.3) FR: Glow-wire test 850C alt. 750C for luminaires in premises open to public or 960°C for luminaires in emergency exits
Aluminum enclosure with polymeric covers spaced from uninsulated live parts.
N/A
(13.3) GB: Requirements according to United Kingdom Building Regulation
Not intended to be used on a suspended ceiling
N/A
Page 44 of 47 Report No. 102761244DAL-002
Photos
TRF No. IEC60598_2_17D
Photo 1 - External view of model VL6000 BEAM
Photo 2 - External view of model VL6000 BEAM
Page 45 of 47 Report No. 102761244DAL-002
Photos
TRF No. IEC60598_2_17D
Photo 3 - Internal view of model VL6000B
Photo 4 - Internal view of model VL6000B
Page 46 of 47 Report No. 102761244DAL-002
Photos
TRF No. IEC60598_2_17D
Photo 5 - View of Ignitor board
Photo 6 - Internal view of model VL6000B
Page 47 of 47 Report No. 102761244DAL-002
Photos
TRF No. IEC60598_2_17D
Photo 7 - Internal view of model VL6000B
This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.
Non-Specific EMC Report Shell Rev. March 2014 Genlyte Thomas Group LLC VL6000
Page 1 of 56
EMC TEST REPORT
Report Number: 102761244DAL-005
Project Number: G102761244
Report Issue Date: November 21, 2016
Product Designation: VL6 Moving Head HID Luminaire
Model(s): VL6000
Standards: FCC 47CFR 15B Issued:2011/04/21 Title 47 CFR Part 15 Subpart B Unintentional Radiators Class B Verification
ICES-005 Issued:2007/02/01 Issue No. 2 Radio Frequency Lighting Devices
CENELEC EN 55015 Issued: 2006/12/01 Limits and Methods of Measurement of Radio Disturbance Characteristics of Electrical Lighting and
Similar Equipment; Incorporating Amendment A1: 5/2007
CENELEC EN 61547 Issued: 01/01/1995 Equipment for General Lighting Purposes EMC Immunity Requirements (IEC 1547: 1995)
CENELEC EN61000-3-2 Issued: 2014/08/01 Electromagnetic Compatibility (EMC) - Part 3-2: Limits - Limits for Harmonic Current Emissions
CENELEC EN61000-3-3 Issued: 2013/08/01 Electromagnetic Compatibility (EMC) -Part 3-3: Limits -Limitation of Voltage Changes, Fluctuations & Flicker in Public Low-Voltage Supply Systems
Tested by: Client: Intertek Testing Services NA, Inc.
1809 10th Street Suite 400 Plano, TX 75074
Genlyte Thomas Group LLC 10911 Petal St
Dallas, TX 75238-2424
Report prepared by Report reviewed by
Gary Shimko Compliance Investigator
Rick Hill Compliance Investigator
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 2 of 56 Genlyte Thomas Group LLC VL6000
1 Introduction and Conclusion
The tests indicated in section 2.0 were performed on the product constructed as described in section 4.0. The remaining test sections are the verbatim text from the actual data sheets used during the investigation. These test sections include the test name, the specified test Method, a list of the actual Test Equipment Used, documentation Photos, Results and raw Data. No additions, deviations, or exclusions have been made from the standard(s) unless specifically noted.
Based on the results of our investigation, we have concluded the product tested complies with the requirements of the standard(s) indicated. The results obtained in this test report pertain only to the item(s) tested.
2 Test Summary
Section Test full name Result Date
3 Client Information
4 Description of Equipment Under Test
5 System Setup and Method
6 Radiated Emissions (CISPR 15: Date)
Pass November 8, 2016
7 AC Mains Conducted Emissions (CISPR 15: Date)
Pass November 9, 2016
& November 23, 2016
9 Harmonics (CENELEC EN61000-3-2: 2014)
Pass November 9, 2016
10 Flicker (CENELEC EN61000-3-3: 2013)
Pass November 9, 2016
11 Electro-Static Discharge Immunity Test (IEC 61000-4-2:2008)
Pass November 11, 2016
12 Radiated, Radio-Frequency, Electromagnetic Immunity (IEC 61000-4-3:2006)
Pass November 14, 2016
13 Electrical Fast Transient/Burst Immunity Test (IEC 61000-4-4:2004)
Pass November 11, 2016
14 Immunity to Surges (IEC 61000-4-5:2005)
Pass November 11, 2016
15 Conducted, Radio-Frequency, Electromagnetic Immunity Test (IEC 61000-4-6:2008)
Pass November 11, 2016
16 Power Frequency Magnetic Field Immunity Test (IEC 61000-4-8:1993)
Pass November 14, 2016
17 Voltage Dips /Interruptions Immunity Test (IEC 61000-4-11:2004)
Pass November 10, 2016
18 Revision History
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 3 of 56 Genlyte Thomas Group LLC VL6000
3 Client Information This EUT was tested at the request of:
Company: Genlyte Thomas Group LLC 10911 Petal St Dallas, TX 75238-2424
Contact: David Valentine
Telephone: (214) 647-7910
Email: [email protected]
4 Description of Equipment Under Test
Manufacturer: Genlyte Thomas Group LLC 10911 Petal Street Dallas, TX 75238-2424 USA
Equipment Under Test
Description Manufacturer Model Number Serial Number
VL6 Moving Head HID
Luminaire
Genlyte Thomas
Group LLC
VL6000 DAL1611081156-001
Receive Date: 11/08/2016
Received Condition: Good
Type: Engineering
Description of Equipment Under Test (provided by client)
The Genlyte Thomas Group LLC VL6 Moving Head Luminaire is a Moving Head High Intensity
Discharge Luminaire.
Equipment Under Test Power Configuration
Rated Voltage Rated Current Rated Frequency Number of Phases
220-240 VAC 8.9 A 50/60 Hz Single Phase
Operating modes of the EUT:
No. Descriptions of EUT Exercising
1 Three dimensional rotating Head HID Luminaire with different colors
Software used by the EUT:
No. Descriptions of EUT Exercising
1 VL6000_101816.bin
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 4 of 56 Genlyte Thomas Group LLC VL6000
5 System Setup and Method
Cables
ID
Description
Length
(m)
Shielding
Ferrites
Termination
1 powerCON AC Mains Power Cord 1.5 No No AC
connector on VL6
2 5-pin DMX cable 1 No No Load Box – Pin 1 tied to metal box
Support Equipment
Description Manufacturer Model Number Serial Number
1DMX Load metal Termination Box
Genlyte / Phillips None None
5.1 Method: Configuration as required by IEC 61547.
5.2 EUT Block Diagram:
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 5 of 56 Genlyte Thomas Group LLC VL6000
5.3 EUT Performance Criteria and Monitoring: Performance as required by IEC 61547.
Product Specific Performance:
No. Description
A During the test, no change of the Iuminous intensity shall be observed and the regulating control, if any, shall operate during the test as intended.
B During the test, the Iuminous intensity may change to any value. After the test, the Iuminous intensity shall be restored to its initial value within 1 min. Regulating controls need not function during the test, but after the test, the mode of the control shall be the same as before the test provided that during the test no mode changing commands were given.
C During and after the test, any change of the luminous intensity is allowed and the lamp(s) may be extinguished. After the test, within 30 min, all functions shall return to normal, if necessary by temporary interruption of the mains supply and/or operating the regulating control. Additional requirement for lighting equipment incorporating a starting device: After the test, the lighting equipment is switched off. After half an hour, it is switched on again. The lighting equipment shall start and operate as intended.
Description of how performance was observed during testing:
No. Description
1 Visual
General notes: The VP6000 utilizes a 24 MHz oscillator on the processor card, which is internally to the processor at 1 GHz and to generate the DDR clock at 400 MHz. The other microcontrollers use 16 MHz oscillators.
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 6 of 56 Genlyte Thomas Group LLC VL6000
6 Radiated Emissions
6.1 Method Tests are performed in accordance with CISPR 22.
TEST SITE: 3m SAC
Measurement Uncertainty
For radiated emissions, labU(3.5 dB at 3m and 3.5 dB at 10m below 1 GHz, and 4.2 dB at 3m above 1
GHz) < CISPRU(5.2 dB), which is the reference value in CISPR 16-4-2 Table 1, hence the compliance of
the product is only based on the measured value, and no measurement uncertainty correction is required, based on CISPR 22 and CISPR 11 (for 2006 and later revisions) Clause 11.
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 7 of 56 Genlyte Thomas Group LLC VL6000
Sample Calculation The field strength is calculated by adding the Antenna Factor and Cable Factor, and subtracting the Amplifier Gain (if any) from the measured reading. The basic equation with a sample calculation is as follows: FS = RA + AF + CF - AG Where
FS = Field Strength in dBV/m
RA = Receiver Amplitude (including preamplifier) in dBV CF = Cable Attenuation Factor in dB AF = Antenna Factor in dB AG = Amplifier Gain in dB In the following table(s), the reading shown on the data table reflects the preamplifier gain. An example for the calculations in the following table is as follows.
Assume a receiver reading of 52.0 dBV is obtained. The antenna factor of 7.4 dB and cable factor of
1.6 dB is added. The amplifier gain of 29 dB is subtracted, giving a field strength of 32 dBV/m. This
value in dBV/m was converted to its corresponding level in V/m.
RA = 52.0 dBV AF = 7.4 dB/m CF = 1.6 dB AG = 29.0 dB
FS = 32 dBV/m
To convert from dBV to V or mV the following was used:
UF = 10(NF / 20)
where UF = Net Reading in V
NF = Net Reading in dBV
Example: FS = RA + AF + CF – AG = 52.0 + 7.4 + 1.6 – 29.0 = 32.0
UF = 10(32 dBV / 20)
= 39.8 V/m
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 8 of 56 Genlyte Thomas Group LLC VL6000
6.2 Test Equipment Used:
Asset
Number Description Manufacturer Model
Serial
Number Cal Date Cal Due
3040
7 Meter RF Cable
26.5GHz EMC lab (cable 1)
Maury Microwave
UC-SMA-MM-276
15.16.109 05/17/2016 05/17/2017
3042 1 Meter RF
Cable 18GHz EMC lab
Maury Microwave
UC-N-MM-36
14.04.114 05/22/2016 05/22/2017
3044 2 Meter RF
Cable 18GHz EMC lab
Maury Microwave
UC-N-MM-78
14.01.391 05/17/2016 05/17/2017
1160
Preamplifier 1-1000 MHz 33dB typical
gain
Com Power PAM-103 441031 02/29/2016 02/28/2017
Rental Receiver Rohde & Schwarz
ESU40 100280 2/23/2016 2/23/2017
19937 Antenna - 20
MHz to 6 GHz
Sunol Sciences JB6 A050707-2 3/9/2016 3/9/2017
Asset
Number Description Manufacturer Model
Serial
Number Cal Date Cal Due
77 EMI Receiver Rohde & Schwarz
ESI 7 100044 5/24/2016 5/24/2017
1612 CISPR 15
3 Axis Loop LaPlace
Instruments RF300-4-08 9114 02/12/2013 VBU
3013
Temperature, Humidity
and Pressure data logger
Modular Signal (MSR)
MSR255 410298 5/4/2016 5/4/2017
Software Utilized:
Name Manufacturer Version
Total Integrated Laboratory Environment
ETS-Lindgren 6.0
6.3 Results: The sample tested was found to Comply.
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 9 of 56 Genlyte Thomas Group LLC VL6000
6.4 Setup Photographs:
Figure 6-1 Radiated Emissions Test Setup
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 10 of 56 Genlyte Thomas Group LLC VL6000
Figure 6-2 Radiated Loop Emissions Test Setup
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 11 of 56 Genlyte Thomas Group LLC VL6000
6.5 Plots/Data:
Intertek Testing ServicesRADIATED EMISSIONS 3m
QP 3m Horizontal
30.00M 100.00M 1.00G
Frequency Hz
0
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
55.0
60.0
65.0
70.0
75.0
80.0A
mplitu
de d
BuV
/m
05:31:47 PM, Tuesday, Nov ember 08, 2016
Operator: Gary Shimko
Job # - G102761244
Company - Genlyte Thomas Group LLC
Model # - VL6000
Serial # - DAL1611081156-001
Pre-Scan
Quasi-Peak Limit
Quasi-Peak Emissions
Figure 6-2 Radiated Emissions 230V 50Hz QP 3m Horizontal
Intertek Testing ServicesRADIATED EMISSIONS 3m
QP 3m Vertical
30.00M 100.00M 1.00G
Frequency Hz
0
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
55.0
60.0
65.0
70.0
75.0
80.0
Am
plitu
de d
BuV
/m
05:02:23 PM, Tuesday, Nov ember 08, 2016
Operator: Gary Shimko
Job # - G102761244
Company - Genlyte Thomas Group LLC
Model # - VL6000
Serial # - DAL1611081156-001
Pre-Scan
Quasi-Peak Limit
Quasi-Peak Emissions
Figure 6-3 Radiated Emissions 230V 50Hz QP 3m Vertical
Figure 6-4 Radiated Emissions A - Axis
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 12 of 56 Genlyte Thomas Group LLC VL6000
Figure 6-5 Radiated Emissions B - Axis
Figure 6-6 Radiated Emissions C - Axis
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 13 of 56 Genlyte Thomas Group LLC VL6000
Table 6-1 Radiated Emissions 230V 50Hz Quasi-Peak Measurements 3m Horizontal
Freq.
MHz
Antenna
Height
cm
Azimuth
degrees
Receiver
Reading
dBuV/m
Antenna
Factor
dB
PreAmp
Factor
dB
Cable
Factor
dB
Final QP
Reading
dBuV/m
Limit QP
dBuV/m
Margin
QP
dB
120.25 249.0 30.0 49.8 13.7 36.0 1.4 28.9 40.0 -11.1
161.45 100.0 299.0 50.4 12.8 36.0 1.6 28.7 40.0 -11.3
226.65 100.0 12.0 55.3 11.7 36.0 1.9 32.9 40.0 -7.1
229.05 100.0 11.0 55.8 11.8 35.9 1.9 33.6 40.0 -6.4
336.05 291.0 39.0 52.9 14.8 35.6 2.3 34.4 47.0 -12.6
623.95 350.0 164.0 45.9 20.0 34.6 3.2 34.5 47.0 -12.5
Table 6-2 Radiated Emissions 230V 50Hz Quasi-Peak Measurements 3m Vertical
Freq.
MHz
Antenna
Height
cm
Azimuth
degrees
Receiver
Reading
dBuV/m
Antenna
Factor
dB
PreAmp
Factor
dB
Cable
Factor
dB
Final QP
Reading
dBuV/m
Limit QP
dBuV/m
Margin
QP
dB
35.52 150.0 81.0 50.3 17.9 36.1 0.7 32.9 40.0 -7.1
39.25 150.0 108.0 52.2 15.1 36.2 0.8 31.9 40.0 -8.1
102.55 150.0 30.0 52.3 11.1 36.0 1.3 28.6 40.0 -11.4
103.75 150.0 82.0 48.4 11.4 36.0 1.3 25.0 40.0 -15.0
155.35 150.1 107.0 55.4 12.9 35.9 1.5 33.9 40.0 -6.1
158.72 207.0 70.0 56.4 12.9 36.0 1.6 34.9 40.0 -5.1
335.98 290.0 190.0 62.8 14.8 35.6 2.3 44.3 47.0 -2.7
815.96 205.0 32.0 50.0 22.1 33.9 3.7 41.9 47.0 -5.1
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 14 of 56 Genlyte Thomas Group LLC VL6000
Table 6-3 Radiated Loop Emissions 230V 50Hz A Axis
Freq.
MHz
Receiver
Reading
dBuV/m
Antenna
Factor
dB
Final QP
Reading
dBuV/m
Limit QP
dBuV/m
Margin
QP
dB
0.051 18.521 -5.785 12.736 88 -75.264
0.078 24.88 -9.403 15.477 85 -69.523
0.092 15.159 -10.847 4.312 79.825 -75.513
0.127 9.298 -13.954 -4.655 66.475 -71.13
0.154 26.722 -15.495 11.227 57.949 -46.723
0.252 21.236 -19.103 2.133 56.712 -54.578
0.351 17.7 -21.45 -3.75 55.462 -59.212
5.144 11.813 -26.932 -15.119 22 -37.119
26.95 10.983 -28.44 -17.456 22 -39.456
Table 6-4 Radiated Loop Emissions 230V 50Hz B Axis
Freq.
MHz
Receiver
Reading
dBuV/m
Antenna
Factor
dB
Final QP
Reading
dBuV/m
Limit QP
dBuV/m
Margin
QP
dB
0.01 37.369 7.729 45.098 88 -42.902
0.016 32.812 3.816 36.628 88 -51.372
0.028 31.489 -0.583 30.907 88 -57.093
0.037 25.226 -2.995 22.231 88 -65.769
0.044 28.076 -4.4 23.676 88 -64.324
0.053 25.565 -6.116 19.449 88 -68.551
0.071 25.463 -8.545 16.918 87.794 -70.875
0.078 26.121 -9.408 16.713 84.981 -68.268
0.13 22.259 -14.128 8.131 65.556 -57.425
0.163 46.233 -15.969 30.264 57.831 -27.567
0.236 39.566 -18.64 20.926 56.914 -35.987
0.394 31.982 -22.099 9.883 54.918 -45.035
0.498 24.873 -23.278 1.595 53.604 -52.009
0.6 22.31 -24.127 -1.817 52.316 -54.133
20.29 10.983 -27.6 -16.617 22 -38.617
Table 6-5 Radiated Loop Emissions 230V 50Hz C Axis
Freq.
MHz
Receiver
Reading
dBuV/m
Antenna
Factor
dB
Final QP
Reading
dBuV/m
Limit QP
dBuV/m
Margin
QP
dB
0.01 21.775 7.729 29.504 88 -58.496
0.026 12.575 -0.011 12.564 88 -75.436
0.033 26.268 -1.934 24.334 88 -63.666
0.051 23.046 -5.76 17.286 88 -70.714
0.057 25.456 -6.706 18.749 88 -69.251
0.064 35.46 -7.647 27.813 88 -60.187
0.078 35.877 -9.398 26.479 85.019 -58.54
0.092 27.897 -10.843 17.054 79.844 -62.79
0.128 22.303 -13.974 8.329 66.4 -58.071
0.131 22.411 -14.224 8.187 64.994 -56.807
0.172 44.397 -16.394 28.004 57.727 -29.724
0.944 17.571 -25.899 -8.328 47.971 -56.298
20.954 10.931 -27.701 -16.77 22 -38.77
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 15 of 56 Genlyte Thomas Group LLC VL6000
Test Personnel: Gary Shimko Test Date: November 8,
2016
Supervising/Reviewing Engineer: (Where Applicable)
Product Standard: CISPR 15: Limit Applied: B
Input Voltage: 230VAC 50 Hz Ambient Temperature: 22.6 ºC
Pretest Verification w/ Ambient Signals or BB Source:
Relative Humidity: 52.39 %
Atmospheric Pressure: 995.0 Mbars mbars
Deviations, Additions, or Exclusions: None
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 16 of 56 Genlyte Thomas Group LLC VL6000
7 AC Mains Conducted Emissions
7.1 Method Tests are performed in accordance with CISPR 15.
TEST SITE: Vertical Ground Reference Plane
Measurement Uncertainty
For conducted emissions, labU(3.1 dB in worst case) < CISPRU
(3.6 dB), which is the reference value in CISPR 16-4-2 Table 1, hence the compliance of the product is only based on the measured value, and no measurement uncertainty correction is required, based on CISPR 22 and CISPR 11 (for 2006 and later revisions) Clause 11.
Sample Calculations The following is how net line-conducted readings were determined: NF = RF + LF + CF + AF
Where NF = Net Reading in dBV
RF = Reading from receiver in dBV LF = LISN or ISN Correction Factor in dB CF = Cable Correction Factor in dB AF = Attenuator Loss Factor in dB
To convert from dBV to V or mV the following was used:
UF = 10(NF / 20)
where UF = Net Reading in V
NF = Net Reading in dBV
Example:
NF = RF + LF + CF + AF = 28.5 + 0.2 + 0.4 + 20.0 = 49.1 dBV
UF = 10(49.1 dBV / 20)
= 285.1 V/m
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 17 of 56 Genlyte Thomas Group LLC VL6000
7.2 Test Equipment Used:
Asset
Number Description Manufacturer Model
Serial
Number Cal Date Cal Due
77 EMI Receiver
rated: 10KHz-7GHz
Rohde & Schwarz
ESI 7 100044 5/24/2016 5/24/2017
975
DC to 18GHz Coaxial RF Cable 3M
Em Chamber
MegaPhase F520NKNK315 11111301002 10/04/2016 10/04/2017
Rental Transient
Limiter HP 11947A 1143972 4/27/2016 4/27/2017
1560
Line Impedance Stabilization
Network 9kHz to 30MHz
Com-Power Corp
LI-215A 191942 12/15/2015 12/14/2016
3013
Temperature, Humidity
and Pressure data logger
Modular Signal (MSR)
MSR255 410298 5/4/2016 5/4/2017
Software Utilized: Conducted Emissions
Name Manufacturer Version
Total Integrated Laboratory
Environment
ETS-Lindgren 6.0
.
7.3 Results: The sample tested was found to Comply.
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 18 of 56 Genlyte Thomas Group LLC VL6000
7.4 Setup Photographs:
Figure 7-1 Conducted Emissions Setup
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 19 of 56 Genlyte Thomas Group LLC VL6000
7.5 Plots/Data:
Intertek Testing ServicesConducted Emissions
Line 1
9.0K 10.0K 100.0K 150.0K
Frequency MHz
-10.0
0
10.0
20.0
30.0
40.0
50.0
60.0
70.0
80.0
90.0
100.0
110.0
120.0A
mplitu
de
dB
uV
01:36:13 PM, Wednesday, November 23, 2016
Operator: Gary Shimko Genlyte VP6000 230V 50Hz
Job # - G102761244
Company - Genlyte Thomas Group LLC
Model # - VL6000
Serial # - DAL1611081156-001
Quasi-Peak Limit
Av erage Limit
Peak Pre-Scan
Quasi Peak Results
Av erage Results
Figure 7-2 Conducted Emissions Line 1 9 kHz to 150 kHz
Intertek Testing ServicesConducted Emissions
Line 2
9.0K 10.0K 100.0K 150.0K
Frequency MHz
-10.0
0
10.0
20.0
30.0
40.0
50.0
60.0
70.0
80.0
90.0
100.0
110.0
120.0
Am
plitu
de
dB
uV
01:16:31 PM, Wednesday, November 23, 2016
Operator: Gary Shimko Genlyte VP6000 230V 50Hz
Job # - G102761244
Company - Genlyte Thomas Group LLC
Model # - VL6000
Serial # - DAL1611081156-001
Quasi-Peak Limit
Av erage Limit
Peak Pre-Scan
Final_QPLine2
Av erage Results
Figure 7-3 Conducted Emissions Line 2 9 kHz to 150 kHz
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 20 of 56 Genlyte Thomas Group LLC VL6000
Figure 7-4 Conducted Emissions Line 1 150 kHz to 30 MHz
Figure 7-5 Conducted Emissions Line 2 150 kHz to 30 MHz
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 21 of 56 Genlyte Thomas Group LLC VL6000
Freq.
MHz
QP
Reading
dBuV
Avg
Readin
g
dBuV
Cable
Factor dB
F
Limiter
ABS
Lisn
Factor
dB
Final
QP
Readin
g dBuV
Limit
QP
dBuV
Margin
QP
dB
Final
Avg
dBuV
Limit
Avg
dBuV
Margin
Avg
dB
1.19 35.556 30.696 0.294 9.59 0.32 45.761 56 -10.239 40.901 46 -5.099
1.28 35.929 29.03 0.297 9.594 0.32 46.141 56 -9.859 39.241 46 -6.759
1.74 36.461 30.36 0.309 9.611 0.303 46.684 56 -9.316 40.584 46 -5.416
1.83 36.538 31.173 0.311 9.614 0.303 46.766 56 -9.234 41.4 46 -4.6
2.29 36.711 30.117 0.319 9.627 0.31 46.967 56 -9.033 40.373 46 -5.627
2.56 37.317 31.065 0.323 9.633 0.31 47.583 56 -8.417 41.331 46 -4.669
2.84 37.181 32.118 0.327 9.639 0.31 47.457 56 -8.543 42.394 46 -3.606
3.39 38.007 32.462 0.334 9.649 0.31 48.3 56 -7.7 42.755 46 -3.245
3.66 36.036 31.417 0.337 9.653 0.31 46.336 56 -9.664 41.717 46 -4.283
3.85 36.47 30.932 0.339 9.656 0.318 46.783 56 -9.217 41.245 46 -4.755
12.4 36.932 28.121 0.383 9.71 0.38 47.405 60 -12.595 38.594 50 -11.406
15.05 37.736 26.59 0.391 9.71 0.4 48.237 60 -11.763 37.09 50 -12.91
Table 7-1 Conducted Emissions Line 1
Freq.
MHz
QP
Reading
dBuV
Avg
Readin
g
dBuV
Cable
Factor dB
F
Limiter
ABS
Lisn
Factor
dB
Final
QP
Readin
g dBuV
Limit
QP
dBuV
Margin
QP
dB
Final
Avg
dBuV
Limit
Avg
dBuV
Margin
Avg
dB
0.09 70.088 NA 0.2 9.605 0.14 80.027 84.47 -4.44 NA NA NA
0.18 48.204 45.07 0.22 9.602 0.71 58.741 64.3 -5.56 55.61 54.3 1.3
1.47 40.877 36.13 0.3 9.602 0.31 51.092 56 -4.91 46.35 46 0.35
1.84 38.393 32.82 0.31 9.614 0.31 48.628 56 -7.37 43.05 46 -2.95
2.11 39.926 35.38 0.32 9.622 0.31 50.174 56 -5.83 45.62 46 -0.38
2.57 39.36 33.62 0.32 9.633 0.31 49.627 56 -6.37 43.88 46 -2.12
2.66 39.203 34.59 0.32 9.635 0.31 49.472 56 -6.53 44.86 46 -1.14
2.75 39.626 34.57 0.33 9.637 0.31 49.899 56 -6.1 44.84 46 -1.16
2.93 40.165 33.57 0.33 9.641 0.31 50.444 56 -5.56 43.85 46 -2.15
3.21 39.234 34.55 0.33 9.646 0.31 49.522 56 -6.48 44.84 46 -1.16
3.39 38.202 32.82 0.33 9.649 0.31 48.495 56 -7.51 43.12 46 -2.88
3.76 39.2 33.7 0.34 9.655 0.32 49.512 56 -6.49 44.01 46 -1.99
3.94 38.217 33.82 0.34 9.657 0.32 48.534 56 -7.47 44.14 46 -1.86
4.21 38.901 33.33 0.34 9.661 0.32 49.224 56 -6.78 43.65 46 -2.35
4.4 37.987 33.12 0.34 9.664 0.32 48.315 56 -7.69 43.44 46 -2.56
9.45 40.631 34.32 0.37 9.707 0.35 51.06 60 -8.94 44.75 50 -5.25
10.29 35.085 28.11 0.38 9.71 0.36 45.53 60 -14.47 38.56 50 -11.44
10.86 39.664 33.13 0.38 9.71 0.37 50.12 60 -9.88 43.59 50 -6.41
11.31 39.733 33.18 0.38 9.71 0.37 50.193 60 -9.81 43.64 50 -6.36
11.76 34.519 26.75 0.38 9.71 0.37 44.98 60 -15.02 37.21 50 -12.79
11.87 39.652 34.93 0.38 9.71 0.37 50.113 60 -9.89 45.39 50 -4.61
Table 7-2 Conducted Emissions Line 2
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 22 of 56 Genlyte Thomas Group LLC VL6000
Test Personnel: Gary Shimko Test Date: November 9, 2016
Supervising/Reviewing Engineer: (Where Applicable)
Product Standard: CISPR 15 Limit Applied: B
Input Voltage: 230VAC/50 Hz
Pretest Verification w/ Ambient Signals or BB Source: Yes
Ambient Temperature: 23.8ºC
Relative Humidity: 56.6 %
Atmospheric Pressure: 987Mbars
Deviations, Additions, or Exclusions: None
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 23 of 56 Genlyte Thomas Group LLC VL6000
8 Harmonics
8.1 Method Tests are performed in accordance with IEC 61000-3-2.
TEST SITE: Immunity Room
8.2 Test Equipment Used:
Asset
Number Description Manufacturer Model
Serial
Number Cal Date Cal Due
1496 Model
MX30K0C4Y20400 & CIC-PC-PCX
Ametek MX30K0C4Y20400 1247A02352 11/8/2016 11/8/2017
3013
Temperature Humidity and Pressure data
logger
Modular Signal (MSR)
MSR255 410297 05/04/2016 05/04/2017
Software Utilized:
Name Manufacturer Version
CTSMXL California Instruments Corp. 1.4.0.13
8.3 Results: The sample tested was found to Comply.
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 24 of 56 Genlyte Thomas Group LLC VL6000
8.4 Setup Photographs:
Figure 9 – 1 Harmonic Test Set-up
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 25 of 56 Genlyte Thomas Group LLC VL6000
8.5 Data:
Harmonics – Class-A per Ed. 3.2 (2009)(Run time)
EUT: VL6000 Beam Wash Tested by: Bill Cullen Test category: Class-A per Ed. 3.2 (2009) (European limits) Test Margin(%): 100 Test date: 11/9/2016 Start time: 8:49:34 AM End time: 8:59:57 AM Test duration (min): 10 Data file name: CTSMXL_H-000713.cts_data Comment: 230V 50Hz Customer: Genlyte Thomas Group LLC. Test Result: Pass Source qualification: Normal Current(blue) & voltage(green) waveforms
- 1 5
- 1 0
- 5
0
5
1 0
1 5
- 3 0 0
- 2 0 0
- 1 0 0
0
1 0 0
2 0 0
3 0 0
Cu
rr
en
t
(A
mp
s)
Vo
lta
ge
(
Vo
lts
)
Harmonics and Class A limit line European Limits – 100%(blue) & 150%(red)
0 . 0
0 . 5
1 . 0
1 . 5
2 . 0
2 . 5
3 . 0
3 . 5
Cu
rr
en
t
RM
S(
Am
ps
)
H a r m o n i c #4 8 1 2 1 6 2 0 2 4 2 8 3 2 3 6 4 0
Test result: Pass Worst harmonic was #11 with 16.33% of the limit.
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 26 of 56 Genlyte Thomas Group LLC VL6000
Current Test Result Summary (Run time)
EUT: VL6000 Beam Wash Tested by: Bill Cullen Test category: Class-A per Ed. 3.2 (2009) (European limits) Test Margin(%): 100 Test date: 11/9/2016 Start time: 8:49:34 AM End time: 8:59:57 AM Test duration (min): 10 Data file name: CTSMXL_H-000713.cts_data Comment: 230V 50Hz Customer: Genlyte Thomas Group LLC. Test Result: Pass Source qualification: Normal THC(A): 0.282 I-THD(%): 3.736 POHC(A): 0.000 POHC Limit(A): 0.320 Highest parameter values during test:
V_RMS (Volts): 229.92 Frequency(Hz): 50.00 I_Peak (Amps): 11.273 I_RMS (Amps): 7.632 I_Fund (Amps): 7.581 Crest Factor: 1.483 Power (Watts): 1731.3 Power Factor: 0.993
Harm# Harms(avg) 100%Limit %of Limit Harms(max) 150%Limit %of Limit Status 2 0.003 1.080 0.0 0.004 1.620 0.24 Pass 3 0.255 2.300 11.1 0.260 3.450 7.53 Pass 4 0.001 0.430 0.0 0.002 0.645 0.25 Pass 5 0.085 1.140 7.4 0.089 1.710 5.20 Pass 6 0.001 0.300 0.0 0.002 0.450 0.41 Pass 7 0.050 0.770 6.6 0.058 1.155 5.02 Pass 8 0.001 0.230 0.0 0.002 0.345 0.48 Pass 9 0.044 0.400 11.1 0.050 0.600 8.40 Pass 10 0.001 0.184 0.0 0.002 0.276 0.60 Pass 11 0.054 0.330 16.3 0.057 0.495 11.48 Pass 12 0.001 0.153 0.0 0.002 0.230 0.75 Pass 13 0.030 0.210 0.0 0.034 0.315 10.81 Pass 14 0.001 0.131 0.0 0.002 0.197 0.90 Pass 15 0.038 0.150 0.0 0.044 0.225 19.77 Pass 16 0.001 0.115 0.0 0.002 0.173 1.00 Pass 17 0.041 0.132 0.0 0.045 0.199 22.52 Pass 18 0.001 0.102 0.0 0.002 0.153 1.14 Pass 19 0.032 0.118 0.0 0.034 0.178 19.25 Pass 20 0.001 0.092 0.0 0.002 0.138 1.46 Pass 21 0.041 0.107 0.0 0.045 0.161 28.03 Pass 22 0.001 0.084 0.0 0.002 0.125 1.54 Pass 23 0.035 0.098 0.0 0.041 0.147 27.58 Pass 24 0.001 0.077 0.0 0.002 0.115 1.86 Pass 25 0.031 0.090 0.0 0.034 0.135 25.53 Pass 26 0.002 0.071 0.0 0.003 0.106 2.99 Pass 27 0.033 0.083 0.0 0.036 0.125 28.94 Pass 28 0.002 0.066 0.0 0.003 0.099 3.06 Pass 29 0.025 0.078 0.0 0.029 0.116 25.31 Pass 30 0.002 0.061 0.0 0.004 0.092 4.16 Pass 31 0.025 0.073 0.0 0.030 0.109 27.13 Pass 32 0.003 0.058 0.0 0.004 0.086 5.02 Pass 33 0.024 0.068 0.0 0.029 0.102 28.49 Pass 34 0.003 0.054 0.0 0.006 0.081 7.28 Pass 35 0.021 0.064 0.0 0.025 0.096 25.64 Pass 36 0.003 0.051 0.0 0.005 0.077 6.06 Pass 37 0.024 0.061 0.0 0.028 0.091 30.68 Pass 38 0.003 0.048 0.0 0.005 0.073 6.62 Pass 39 0.022 0.058 0.0 0.026 0.087 30.02 Pass 40 0.003 0.046 0.0 0.004 0.069 5.43 Pass
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 27 of 56 Genlyte Thomas Group LLC VL6000
Test Personnel: Gary Shimko Test Date: November 9, 2016
Supervising/Reviewing Engineer: (Where Applicable)
Product Standard: IEC 61000-3-2 Limit Applied: A
Input Voltage: 230V 50Hz
Pretest Verification w/ Artifact:
Ambient Temperature: 23.8 ºC
Relative Humidity: 56.7%
Atmospheric Pressure: 967 mbars
Deviations, Additions, or Exclusions: None
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 28 of 56 Genlyte Thomas Group LLC VL6000
9 Flicker
9.1 Method Tests are performed in accordance with IEC 61000-3-3.
TEST SITE: Immunity Room
9.2 Test Equipment Used:
Asset
Number Description Manufacturer Model
Serial
Number Cal Date Cal Due
1496 Model
MX30K0C4Y20400 & CIC-PC-PCX
Ametek MX30K0C4Y20400 1247A02352 11/8/2016 11/8/2017
3013
Temperature Humidity and Pressure data
logger
Modular Signal (MSR)
MSR255 410297 05/04/2016 05/04/2017
Software Utilized:
Name Manufacturer Version
CTSMXL California Instruments Corp. 1.4.0.13
9.3 Results: The sample tested was found to Comply.
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 29 of 56 Genlyte Thomas Group LLC VL6000
9.4 Setup Photographs:
Figure 10 – 1 Flicker Test Set-up
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 30 of 56 Genlyte Thomas Group LLC VL6000
9.5 Data:
Flicker Test Summary per EN/IEC61000-3-3 Ed. 3.0 (2013) (Run time)
EUT: VL6000 Beam Wash Tested by: Bill Cullen Test category: All parameters (European limits) Test Margin: 100 Test date: 11/9/2016 Start time: 9:21:11 AM End time: 11:22:44 AM Test duration (min): 120 Data file name: CTSMXL_F-000736.cts_data Comment: F7 Customer: Intertek Test Result: Pass Status: Test Completed Psti and limit line European Limits
0 . 2 5
0 . 5 0
0 . 7 5
1 . 0 0
Ps
t
9:
31
:3
2
9:
41
:3
2
9:
51
:3
2
10
:0
1:
32
10
:1
1:
32
10
:2
1:
32
10
:3
1:
32
10
:4
1:
32
10
:5
1:
32
11
:0
1:
32
11
:1
1:
31
11
:2
1:
31
Plt and limit line
0 . 2
0 . 3
0 . 4
0 . 5
0 . 6
Plt
11
:2
1:
31
Parameter values recorded during the test: Vrms at the end of test (Volt): 229.79 Highest dt (%): 0.20 Test limit (%): N/A N/A T-max (mS): 0.0 Test limit (mS): 500.0 Pass Highest dc (%): 0.00 Test limit (%): 3.30 Pass Highest dmax (%): -0.12 Test limit (%): 4.00 Pass Highest Pst (10 min. period): 0.178 Test limit: 1.000 Pass Highest Plt (2 hr. period): 0.141 Test limit: 0.650 Pass
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 31 of 56 Genlyte Thomas Group LLC VL6000
Test Personnel: Gary Shimko Test Date: November 9, 2016
Supervising/Reviewing Engineer: (Where Applicable)
Product Standard: IEC 61000-3-3 Limit Applied: NA
Input Voltage: 230VAC/50 Hz
Pretest Verification w/ Artifact:
Ambient Temperature: 23.8ºC
Relative Humidity: 57.6 %
Atmospheric Pressure: 978 mbars
Deviations, Additions, or Exclusions: None
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 32 of 56 Genlyte Thomas Group LLC VL6000
10 Electrostatic Discharge Immunity Test
10.1 Method Tests are performed in accordance with IEC 61000-4-2.
TEST SITE: Immunity Lab.
10.2 Test Equipment Used:
Asset
Number Description Manufacturer Model
Serial
Number Cal Date Cal Due
DEN Electrostatic Discharge Simulator
NoiseKen ESS-200AX 8089C011357 8/25/2016 8/25/2017
3013
Temperature Humidity and Pressure data
logger
Modular Signal (MSR)
MSR255 410297 05/04/2016 05/04/2017
Software Utilized:
Name Manufacturer Version
None
10.3 Results: The sample tested was found to Comply.
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 33 of 56 Genlyte Thomas Group LLC VL6000
10.4 Setup Photographs:
Figure 11 - 1 ESD Test Set-up
Figure 11 - 2 ESD Test Points on Front Panel
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 34 of 56 Genlyte Thomas Group LLC VL6000
Figure 11 - 3 ESD Test Points on Back I/O Panel
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 35 of 56 Genlyte Thomas Group LLC VL6000
Data:
Test Point
Discharge Voltage Type
Test Voltages, Polarities and Result Classification
2 kV 4 kV 6 kV 8 kV
Air D
ischarg
es o
nly
above 8
kV
15 kV __ kV
Pos Neg Pos Neg Pos Neg Pos Neg Pos Neg Pos Neg
HCP Contact A A A A
VCP Contact A A A A
1 Air A A A A A A A A
2 Air A A A A A A A A
3 Air A A A A A A A A
4 Air A A A A A A A A
Test Personnel: Gary Shimko Test Date: November 11, 2016
Supervising/Reviewing Engineer: (Where Applicable)
Product Standard: (IEC 61000-4-2:2008) Test Levels: See Table Above
Input Voltage: 230VAC/50Hz Performance Criteria: See Report Section 5.3
Waveform Verified on Oscilloscope:
Ambient Temperature: 23.4ºC
Relative Humidity: 55.8 %
470k x 2 Strap(s) Verified:
Yes Atmospheric Pressure: 978 mbars
Notes: (1) The EUT met the requirements without any degradation of performance. Deviations, Additions, or Exclusions: None
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 36 of 56 Genlyte Thomas Group LLC VL6000
11 Radiated, radio-frequency, electromagnetic field immunity test
11.1 Method Tests are performed in accordance with IEC 61000-4-3.
TEST SITE: Compact Chamber.
11.2 Test Equipment Used:
Asset
Number Description Manufacturer Model
Serial
Number Cal Date Cal Due
978 RF Power Meter
Hewlett Packard 437B 3125U26228 11/08/2016 11/08/2017
569 Signal Generator
Rhode & Schwarz SMR20 101111 11/08/2016 11/08/2017
1054 Cable L-Com CA6NMNM010 2 CNR CNR
207 Antenna Amplifier Research AT5080 306847 CNR CNR
75
E Field Probe rated: 10kHz-1GHz Holaday HI4422 101758 09/01/2016 09/01/2017
Rental Amplifier IFI SMCC250 L410-0607 CNR CNR
Rental Amplifier IFI SCCX500 L431-0607 CNR CNR
152 Directional Coupler
Amplifier Research DC6080 304859 08/24/2016 08/24/2017
Software Utilized:
Name Manufacturer Version
Total Integrated Laboratory Environment
ETS-Lindgren 6.0
11.3 Results: The sample tested was found to Comply.
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 37 of 56 Genlyte Thomas Group LLC VL6000
11.4 Setup Photographs:
Figure 12 -1 Radiated, radio-frequency, electromagnetic field immunity test set-up
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 38 of 56 Genlyte Thomas Group LLC VL6000
11.5 Data:
Field Level (V/m)
Frequency Range MHz
Antenna Polarity, Azimuths and Result Classification
Vertical Horizontal
0 90 180 270 0 90 180 270
3 80-1000 A A A A A A A A
Test Personnel:
Gary Shimko
Test Date:
November 14, 2016
Supervising/Reviewing Engineer: (Where Applicable)
Product Standard: (IEC 61000-4-3:2006) Test Levels: See Table Above
Input Voltage: 230VAC/50Hz Performance Criteria: See Report Section 5.3
Waveform Verified on Oscilloscope:
Ambient Temperature: 23.8 ºC
Relative Humidity: 45.54%
Atmospheric Pressure: 998 mbars
Notes: (1) The EUT met the requirements without any degradation of performance. Deviations, Additions, or Exclusions: None
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 39 of 56 Genlyte Thomas Group LLC VL6000
12 Electrical Fast Transient/Burst Immunity Test
12.1 Method Tests are performed in accordance with IEC 61000-4-4.
TEST SITE: Immunity Lab.
12.2 Test Equipment Used:
Asset
Number Description Manufacturer Model
Serial
Number Cal Date Cal Due
3420
EMC Immunity
Tester EFT, Combo-wave Surge, Ring-Wave Surge
ThermoFisher EMC
ProPlus 1603365 08/25/2016 08/25/2017
3013
Temperature, Humidity
and Pressure data logger
Modular Signal (MSR)
MSR255 410298 5/4/2016 5/4/2017
Software Utilized:
Name Manufacturer Version
CEWare32 Thermo Electron Corp. Version 4.00
12.3 Results: The sample tested was found to Comply.
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 40 of 56 Genlyte Thomas Group LLC VL6000
12.4 Setup Photographs:
Figure 13 -1 Electrical Fast Transient/Burst Immunity Test Set-up
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 41 of 56 Genlyte Thomas Group LLC VL6000
12.5 Test Data:
Test Point
Coupling Method
Test Voltages, Polarities, and Result Classification
0.25kV 0.5kV 1 kV 2 kV 4 kV
pos neg pos neg pos neg pos neg pos neg
Power L1, L2, PE Direct A A
Test Personnel: Gary Shimko Test Date: November 11, 2016
Supervising/Reviewing Engineer: (Where Applicable)
Product Standard: EN 61547 Test Levels: See Table Above
Input Voltage: 230VAC/50Hz Performance Criteria: See Report Section 5.3
Waveform Verified on Oscilloscope:
Ambient Temperature: 23.8 ºC
Relative Humidity: 56.7 %
Atmospheric Pressure: 987 mbars
Notes: (1) The EUT met the requirements without any degradation of performance. Deviations, Additions, or Exclusions: None
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 42 of 56 Genlyte Thomas Group LLC VL6000
13 Immunity to Surge
13.1 Method Tests are performed in accordance with IEC 61000-4-5.
TEST SITE: Immunity Lab.
13.2 Test Equipment Used:
Asset
Number Description Manufacturer Model
Serial
Number Cal Date Cal Due
3420
EMC Immunity
Tester EFT, Combo-wave Surge, Ring-Wave Surge
ThermoFisher EMC
ProPlus 1603365 08/25/2016 08/25/2017
3013
Temperature, Humidity
and Pressure data logger
Modular Signal (MSR)
MSR255 410298 5/4/2016 5/4/2017
Software Utilized:
Name Manufacturer Version
CEWare32 Thermo Electron Corp. Version 4.00
13.3 Results: The sample tested was found to Comply.
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 43 of 56 Genlyte Thomas Group LLC VL6000
13.4 Setup Photographs:
Figure 14 -1 Surge Test Setup
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 44 of 56 Genlyte Thomas Group LLC VL6000
13.5 Test Data:
Test
Test Voltages, Polarities, and Result Classification
0.5kV 1kV 2kV 4kV
pos neg pos neg pos neg pos neg
L1-PE, at 0 deg A A A A A A
L1-PE, at 90 deg A A A A A A
L1-PE, at 180 deg A A A A A A
L1-PE, at 270 deg A A A A A A
N-PE, at 0 deg A A A A A A
N-PE, at 90 deg A A A A A A
N-PE, at 180 deg A A A A A A
N-PE, at 270 deg A A A A A A
L1-N, at 0 deg A A A A
L1-N, at 90 deg A A A A
L1-N, at 180 deg A A A A
L1-N, at 270 deg A A A A
Test Personnel: Gary Shimko Test Date: November 11, 2016
Supervising/Reviewing Engineer: (Where Applicable)
Product Standard: (IEC 61000-4-5:2005) Test Levels: See Table Above
Input Voltage: 230VAC/50Hz Performance Criteria: See Report Section 5.3
Waveform Verified on Oscilloscope:
Ambient Temperature: 23.8 ºC
Relative Humidity: 56.7%
Atmospheric Pressure: 967 mbars
Notes: (1) The EUT met the requirements without any degradation of performance. Deviations, Additions, or Exclusions: None
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 45 of 56 Genlyte Thomas Group LLC VL6000
14 Conducted, radio-frequency, electromagnetic field immunity test
14.1 Method Tests are performed in accordance with IEC 61000-4-6.
TEST SITE: Immunity Lab.
14.2 Test Equipment Used:
Asset
Number Description Manufacturer Model
Serial
Number Cal Date Cal Due
95 Power Sensor
with 437B Power Meter
HP HP 8482H 3318A07268 04/19/2016 04/19/2017
198 Signal
Generator Rohde & Schwarz
SMT03 825784/0016 09/13/2016 09/13/2017
3082 Power
Amplifier Com-Power
Corp ACS-250-
100w 711970 06/17/2015 VBU
102 Passive
Impedance Adapter
FCC FCC-801-150-50-
CDN 04091 10/17/2016 10/17/2017
103 Passive
Impedance Adapter
FCC FCC-801-150-50-
CDN 04092 10/17/2016 10/17/2017
3084 Power
Attenuator Com-Power
Corp ATTN-6-
100W 521789 08/18/2016 08/18/2017
88 Coupling
Decoupling Network
FCC FCC-801-M3-25A
01027 08/25/2016 08/25/2017
3013
Temperature, Humidity and Pressure data
logger
Modular Signal (MSR)
MSR255 410297 05/04/2016 05/04/2017
76 EM Injection
Clamp FCC
F-2031-23mm
357 08/30/2016 08/30/2017
Software Utilized:
Name Manufacturer Version
Total Integrated Laboratory Environment
ETS Lindgren Version 6
14.3 Results: The sample tested was found to Comply.
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 46 of 56 Genlyte Thomas Group LLC VL6000
14.4 Setup Photographs:
Figure 15 -1 Conducted, radio-frequency, electromagnetic field immunity test
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 47 of 56 Genlyte Thomas Group LLC VL6000
14.5 Test Data:
Injection Device Type Port Description Test Level (Vrms)
Result Classification
CDN AC Power 3 A
Test Personnel: Gary Shimko Test Date: November 11, 2016
Supervising/Reviewing Engineer: (Where Applicable)
Product Standard: (IEC 61000-4-6:2008) Test Levels: See Table Above
Input Voltage: 230VAC/50Hz Performance Criteria: See Report Section 5.3
Waveform Verified on Oscilloscope:
Ambient Temperature: 23.8 ºC
Relative Humidity: 56.7 %
Atmospheric Pressure: 967 mbars
Notes: (1) The EUT met the requirements without any degradation of performance. Deviations, Additions, or Exclusions: None
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 48 of 56 Genlyte Thomas Group LLC VL6000
15 Power Frequency Magnetic Field Immunity Test
15.1 Method
Tests are performed in accordance with IEC 61000-4-8.
TEST SITE: Immunity Lab.
15.2 Test Equipment Used:
Asset
Number Description Manufacturer Model
Serial
Number Cal Date Cal Due
34 Ground Bond
Tester Associated Research
3130 9350041 04/08/2016 04/08/2017
94
Magnetic Field Loop rated: 50/60 Hz, 100A/m
FCC Magnetic
Field Loop 01026 05/15/2002 VBU
3178 AC Clamp
meter Klein Tools CL 200 0615X-C2 12/03/2015 12/03/2016
3013
Temperature, Humidity and Pressure data
logger
Modular Signal (MSR)
MSR255 410298 5/4/2016 5/4/2017
Software Utilized:
Name Manufacturer Version
None
15.3 Results:
The sample tested was found to Comply.
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 49 of 56 Genlyte Thomas Group LLC VL6000
15.4 Setup Photographs:
Figure 16-1 Power Frequency Magnetic Field Immunity Test Vertical Plane
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 50 of 56 Genlyte Thomas Group LLC VL6000
Figure 16-2 Power Frequency Magnetic Field Immunity Test Vertical Plane
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 51 of 56 Genlyte Thomas Group LLC VL6000
Figure 16-3 Power Frequency Magnetic Field Immunity Test Horizontal Plane
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 52 of 56 Genlyte Thomas Group LLC VL6000
15.5 Test Data:
Test Location/ Mode/ EUT AC Input
Test Level (A/m)
Frequency (Hz)
Result Classification
X – Axis Y – Axis Z – Axis
Luminaire /On/50Hz 3 50 A A A
Luminaire /On/60Hz 3 60 A A A
Test Personnel: Gary Shimko Test Date: November 14, 2016
Supervising/Reviewing Engineer: (Where Applicable)
Product Standard: (IEC 61000-4-8:1993) Test Levels: See Table Above
Input Voltage: 230VAC/50Hz Performance Criteria: See Report Section 5.3
Ambient Temperature: 23.8ºC
Relative Humidity: 56.7 %
Loop Current Verified: 3.5 Amps Atmospheric Pressure: 987 mbars
Notes: (1) The EUT met the requirements without any degradation of performance. Deviations, Additions, or Exclusions: None
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 53 of 56 Genlyte Thomas Group LLC VL6000
16 Voltage Dips / Interruptions Immunity Tests
16.1 Method Tests are performed in accordance with IEC 61000-4-11.
TEST SITE: Immunity Lab.
16.2 Test Equipment Used:
Asset
Number Description Manufacturer Model
Serial
Number Cal Date Cal Due
1496
Model MX30K0C4Y20400
& CIC-PC-PCX
Power Analyzer
Ametek MX30K0C4Y20400 1247A02352 11/8/2016 11/8/2017
3013
Temperature, Humidity and Pressure data
logger
Modular Signal (MSR)
MSR255 410298 5/4/2016 5/4/2017
Software Utilized:
Name Manufacturer Version
MX Series MXGUI California Instruments 2.2.0.9 Feb. 22, 2010
16.3 Results: The sample tested was found to Comply.
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 54 of 56 Genlyte Thomas Group LLC VL6000
16.4 Setup Photographs:
Figure 17-1 Voltage Dips / Interruptions Immunity Tests Set-up
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 55 of 56 Genlyte Thomas Group LLC VL6000
16.5 Test Data:
Specification Rated Voltage (Vac)
Frequency (Hz)
Voltage Test Level (%)
Voltage Dip (%)
Test Voltage (Vac)
Duration
Result Classification
0 deg
180 deg
<5%UT for 0.5 Cycle 230 50 0 100 0.0 0.5 Cycle C (1) C (1)
70%UT for 25 Cycles 230 50 70 30 161 10 Cycles C (1) C (1)
Test Personnel: Gary Shimko Test Date: November 10, 2016
Supervising/Reviewing Engineer: (Where Applicable)
Product Standard: (IEC 61000-4-11:2004)
Test Levels: See Table Above
Input Voltage: 230VAC/50Hz Performance Criteria: See Report Section 5.3
Waveform Verified on Oscilloscope:
Ambient Temperature: 23.8 ºC
Relative Humidity: 56.7 %
Atmospheric Pressure: 987 mbars
Notes: (1) The EUT met the requirements for a High Intensity Discharge (HID) Luminaire. Any severe power drop or interruption will cause the HID Lamp to drop-out (extinguish) and will not restrike until the lamp is allowed to cool. There was no degradation of performance in the motion motor system. Deviations, Additions, or Exclusions: “Any interruption in the power supply, or even a serious voltage dip for a few cycles, causes any HID lamp to go out. It takes minutes before the lamp will restart, because the arc tube has to cool, and the internal vapor pressure has to decrease to the point when the arc can restrike. This restrike time, together with the warm-up period, means an 8 min to 15 min waiting period before full light returns.” http://ecmweb.com/lighting-amp-control/voltage-variations-and-arc-discharge-lamps
Intertek Report Number: 102761244DAL-005 Issued: November 21, 2016
Non-Specific EMC Report Shell Rev. March 2014 Page 56 of 56 Genlyte Thomas Group LLC VL6000
17 Revision History
Revision
Level
Date Report Number Prepared
By
Reviewed
By
Notes
0 11/21/2016 102761244DAL-5-10 RLH
Secret