Download - Volumetric and Mass Measurements
![Page 1: Volumetric and Mass Measurements](https://reader036.vdocuments.net/reader036/viewer/2022062323/56815db7550346895dcbe666/html5/thumbnails/1.jpg)
BIO 222
Volumetric and Mass Measurements
![Page 2: Volumetric and Mass Measurements](https://reader036.vdocuments.net/reader036/viewer/2022062323/56815db7550346895dcbe666/html5/thumbnails/2.jpg)
Prefixes that you will encounter: “Small”
Deci 10-1 d (dl)Centi 10-2 c (cm) Milli 10-3 m (msec) Micro 10-6 g) Nano 10-9 n (nm) Pico 10-12 p (pM) Femto 10-15 f
(fmol)
![Page 3: Volumetric and Mass Measurements](https://reader036.vdocuments.net/reader036/viewer/2022062323/56815db7550346895dcbe666/html5/thumbnails/3.jpg)
“Large”Kilo 103 k (km)Mega 106 M (Mb) Giga 109 G (GHz)
![Page 4: Volumetric and Mass Measurements](https://reader036.vdocuments.net/reader036/viewer/2022062323/56815db7550346895dcbe666/html5/thumbnails/4.jpg)
Mass Measurements Mass – a measure of the amount of matter
an object has; constant regardless of position Weight – a measure of how strongly an
object is pulled by the earth’s gravity; varies with the distance from the earth’s center
As long as you are working at or near the earth’s surface, weight is an accurate indicator of mass.
Basic unit = Gram (g).
![Page 5: Volumetric and Mass Measurements](https://reader036.vdocuments.net/reader036/viewer/2022062323/56815db7550346895dcbe666/html5/thumbnails/5.jpg)
Laboratory Balances: Measuring Mass
Scientists usually refer to a “balance” not “scale”Most are now electronic, with digital readout and
few moving parts. Older mechanical balances with knobs are still
in use. If you need to use one, seek instruction (wrong use can damage them).
Maximum capacity of balance is usually shown on the instrument. DO NOT EXCEED.
Be sure that surface is level (check bubble).
![Page 6: Volumetric and Mass Measurements](https://reader036.vdocuments.net/reader036/viewer/2022062323/56815db7550346895dcbe666/html5/thumbnails/6.jpg)
Common laboratory balancesTop-loading balance: Weighs to 0.01g.
Wind screen not needed.Analytical balance: Weighs to 0.0001 g
(i.e. 1/10 of a milligram). Has a wind screen to protect the balance pan from breezes.
Microbalance: Weighs to 0.000001 g (1µg) or less. For specialized uses only.
Intermediate sizes exist as well.
![Page 7: Volumetric and Mass Measurements](https://reader036.vdocuments.net/reader036/viewer/2022062323/56815db7550346895dcbe666/html5/thumbnails/7.jpg)
Balances Top-loading Analytical
![Page 8: Volumetric and Mass Measurements](https://reader036.vdocuments.net/reader036/viewer/2022062323/56815db7550346895dcbe666/html5/thumbnails/8.jpg)
Bubble level on top-loading balance
If bubble is not centered, adjust the feet of the balance until it is. Consult a professor or lab coordinator if in doubt.
![Page 9: Volumetric and Mass Measurements](https://reader036.vdocuments.net/reader036/viewer/2022062323/56815db7550346895dcbe666/html5/thumbnails/9.jpg)
Left: MicrobalanceMechanical design
(many knobs on front.)
Right: “Analytical plus” weighs to 0.00001 g (10 µg)Electronic design
Balances in Plyler 139 (Instrumentation Lab)
![Page 10: Volumetric and Mass Measurements](https://reader036.vdocuments.net/reader036/viewer/2022062323/56815db7550346895dcbe666/html5/thumbnails/10.jpg)
Typical weighing procedureUse weighing paper or plastic “boat”Place on pan. Close windscreen. Press tare
(or zero) to bring the display back to zero.Open windscreen. Carefully add
substance. Wait for reading to stabilize.As you near the desired mass, tap spatula
to add a few grains at a time. Close windscreen before final measurement.
When finished, clean balance.
![Page 11: Volumetric and Mass Measurements](https://reader036.vdocuments.net/reader036/viewer/2022062323/56815db7550346895dcbe666/html5/thumbnails/11.jpg)
Tools for weighing
![Page 12: Volumetric and Mass Measurements](https://reader036.vdocuments.net/reader036/viewer/2022062323/56815db7550346895dcbe666/html5/thumbnails/12.jpg)
Steps in weighing(balance in chemical stockroom)
![Page 13: Volumetric and Mass Measurements](https://reader036.vdocuments.net/reader036/viewer/2022062323/56815db7550346895dcbe666/html5/thumbnails/13.jpg)
Volumetric measurements
Basic units of volumetric measurement is liter (abbreviation is letter L – upper or lower case)
1 mL = 1 cc1 mL of water weighs 1 g
1 liter of water weighs 1 kg
Consider the purposes of common glassware:
![Page 14: Volumetric and Mass Measurements](https://reader036.vdocuments.net/reader036/viewer/2022062323/56815db7550346895dcbe666/html5/thumbnails/14.jpg)
Beakers: Mixing and dispensing
Wide mouth, good for stirring but hard to seal for storage
Lip, good for pouringmL graduations, if present, are VERY
approximate; neither accurate nor precise
![Page 15: Volumetric and Mass Measurements](https://reader036.vdocuments.net/reader036/viewer/2022062323/56815db7550346895dcbe666/html5/thumbnails/15.jpg)
Conical (Erlenmeyer) Flasks: Mixing and storingShape is good for swirling to mix solutions.Narrow mouth is easy to seal for storage
(using stopper or Parafilm).Not as easy to pour things into or
out of it, compared to a beaker.Like a beaker, graduations
are neither accurate nor precise.
![Page 16: Volumetric and Mass Measurements](https://reader036.vdocuments.net/reader036/viewer/2022062323/56815db7550346895dcbe666/html5/thumbnails/16.jpg)
Graduated cylinders: MeasuringCylindrical shape gives
good precision and accuracy.Graduations can measure
any volume within the size range of the cylinder.
Not an ideal shape for mixing, but it can be done. (More on this when we discuss making solutions.)
![Page 17: Volumetric and Mass Measurements](https://reader036.vdocuments.net/reader036/viewer/2022062323/56815db7550346895dcbe666/html5/thumbnails/17.jpg)
Volumetric flasks: Measuring and making solutions
Narrow neck gives excellent precision.Individually calibrated for excellent
accuracy.Shape good for swirling to dissolve.Can only be used to measure one volume
Common sizes: 10, 25, 50, 100, 250, 500, 1000 mL
Expensive – do not use for storage.
![Page 18: Volumetric and Mass Measurements](https://reader036.vdocuments.net/reader036/viewer/2022062323/56815db7550346895dcbe666/html5/thumbnails/18.jpg)
Volumetric flask
![Page 19: Volumetric and Mass Measurements](https://reader036.vdocuments.net/reader036/viewer/2022062323/56815db7550346895dcbe666/html5/thumbnails/19.jpg)
Smaller volumes: PipettesGlass/plastic serological pipettes
1 mL, 5 mL, 10 mL, 20 mL
Pipettors with disposable tipsMost are adjustable up to a specified max.
volume10 µL, 20 µL, 100 µL, 200 µL, 1000 µL, 5000
µL
![Page 20: Volumetric and Mass Measurements](https://reader036.vdocuments.net/reader036/viewer/2022062323/56815db7550346895dcbe666/html5/thumbnails/20.jpg)
Glass pipettesTop: volumetric pipette - measures a single volume up to an engraved line.
Bottom three: serological pipettes - many graduations, can measure odd volumes, somewhat less accurate than volumetric pipettes
![Page 21: Volumetric and Mass Measurements](https://reader036.vdocuments.net/reader036/viewer/2022062323/56815db7550346895dcbe666/html5/thumbnails/21.jpg)
Adjustable pipettors
![Page 22: Volumetric and Mass Measurements](https://reader036.vdocuments.net/reader036/viewer/2022062323/56815db7550346895dcbe666/html5/thumbnails/22.jpg)
Most labware can be glass or plastic Plastic
inexpensive and disposablenot very fragile can’t be heated on hotplate or burnermay be reactive or contaminate sampleoften the graduations are imprecise
GlassMore expensiveless reactive or likely to contaminatemay adsorb ions and other molecules wettable: a film of water is left clinging to glass
![Page 23: Volumetric and Mass Measurements](https://reader036.vdocuments.net/reader036/viewer/2022062323/56815db7550346895dcbe666/html5/thumbnails/23.jpg)
Wettability issues (esp. glass)If you put exactly 100 mL of water into a glass
container, when you pour it out it will dispense less than 100 mL. The rest is clinging to the glass.
Accurate instruments (graduated cylinders, volumetric flasks, serological pipets) may be marked TC or TD.TC = “to contain”TD = “to deliver”
![Page 24: Volumetric and Mass Measurements](https://reader036.vdocuments.net/reader036/viewer/2022062323/56815db7550346895dcbe666/html5/thumbnails/24.jpg)
TC vs. TDWhen an instrument marked TC is filled to a
particular graduation, it contains that volume. When emptied, it will deliver less than that volume, due to wettability/clinging water.
To compensate for this, TD instruments actually contain slightly more than the marked volume, but they deliver the specified amount.This assumes the liquid is water. Can’t use
TD for other liquids, because greater or lesser amount might cling (e.g. maple syrup, alcohol).
![Page 25: Volumetric and Mass Measurements](https://reader036.vdocuments.net/reader036/viewer/2022062323/56815db7550346895dcbe666/html5/thumbnails/25.jpg)
TC vs. TD – which to choose?Use a TD if you are using water, and you
care most about the volume that comes out.
Use a TC:If measuring something other than
water.If you care most about how much is
inside, e.g. if mixing salt and water to a total volume of exactly 1 L.
![Page 26: Volumetric and Mass Measurements](https://reader036.vdocuments.net/reader036/viewer/2022062323/56815db7550346895dcbe666/html5/thumbnails/26.jpg)
TC vs. TD: questions to ponder
TD pipettes are much more common than TC.Why?
![Page 27: Volumetric and Mass Measurements](https://reader036.vdocuments.net/reader036/viewer/2022062323/56815db7550346895dcbe666/html5/thumbnails/27.jpg)
TC vs. TD: questions to ponder
TC volumetric flasks are much more common than TD. Why?
![Page 28: Volumetric and Mass Measurements](https://reader036.vdocuments.net/reader036/viewer/2022062323/56815db7550346895dcbe666/html5/thumbnails/28.jpg)
TC vs. TD: questions to ponder
Both kinds of graduated cylinders are common. In which situation would you use each?
![Page 29: Volumetric and Mass Measurements](https://reader036.vdocuments.net/reader036/viewer/2022062323/56815db7550346895dcbe666/html5/thumbnails/29.jpg)
TC vs. TD: questions to ponder
A plastic graduated cylinder has the inscription “TC/TD.” Why?
![Page 30: Volumetric and Mass Measurements](https://reader036.vdocuments.net/reader036/viewer/2022062323/56815db7550346895dcbe666/html5/thumbnails/30.jpg)
Other itemsPasteur or transfer pipet – cheap, thin
disposable, “eye dropper” Screw-cap centrifuge tubes (15 mL, 50
mL) – good for sample storage, whether you will centrifuge or not.
Snap-top microcentrifuge tubes (1.5 mL), commonly called “Eppendorf tubes” – commonly used for storage of small samples.
![Page 31: Volumetric and Mass Measurements](https://reader036.vdocuments.net/reader036/viewer/2022062323/56815db7550346895dcbe666/html5/thumbnails/31.jpg)