WIND CAPACITY
N3
DO NOT SCALE DRAWINGS. USE WRITTEN DIMENSIONS ONLY.
THE OWNER, BUILDER AND/OR SUB-CONTRACTORS SHALL VERIFY ALL DIMENSIONS,LEVELS, SET-BACKS AND ANY SPECIFICATIONS PRIOR TO COMMENCING ANY WORKSOR ORDERING MATERIALS AND SHALL BE RESPONSIBLE FOR ENSURING THAT ALL BUILDING WORKSCONFORM TO THE BUILDING CODE OF AUSTRALIA, AUSTRALIAN STANDARDS CODES (CURRENT EDITIONS),BUILDING REGULATIONS, LOCAL BY-LAWS AND TOWN PLANNING REQUIREMENTS.REPORT ALL DISCREPANCIES TO THIS OFFICE FOR CLARIFICATION.
ALL WORKS SHALL COMPLY WITH BUT NOT LIMITED TO THE FOLLOWING AUSTRALIAN STANDARDS:A.S. 1288 – 2006 GLASS IN BUILDINGS – SELECTION & INSTALLATION.A.S. 1562 – 1992 DESIGN & INSTALLATION OF SHEET ROOF & WALL CLADDING.A.S. 1684 – 2010 NATIONAL TIMBER FRAMING CODE.
A.S. 1860 – 1998 INSTALLATION OF PARTICLEBOARD FLOORING.A.S. 2049 – 2002 ROOF TILES.A.S. 2050 – 2002 FIXING OF ROOF TILES.A.S. 2870 – 2011 RESIDENTIAL SLABS & FLASHINGS. (PART 1)A.S. 2904 – 1986 DAMP-PROOF COURSES & FLASHINGS.A.S. 3600 – 2009 CONCRETE STRUCTURES.A.S. 3660.2 – 2000 CODE OF PRACTICE FOR PHYSICAL BARRIERUSED IN THE PROTECTION OF BUILDINGS AGAINST SUBTERRANEAN TERMITES.
A.S. 3700 – 2001 MASONRY IN BUILDINGS.A.S. 3740 – 2004 WATERPROOFING OF WET AREAS IN RESIDENTIAL BUILDINGS.A.S. 3786 – Am 2004 SMOKE ALARMS.A.S. 4055 – 2006 WIND LOADINGS FOR HOUSING.A.S. 4100 – 1990 STEEL STRUCTURES.
THESE PLANS SHALL BE READ IN CONJUNCTIONWITH ANY STRUCTURAL OR CIVIL ENGINEERING COMPUTATIONS AND DRAWINGS.
THESE PLANS SHALL BE READ IN CONJUNCTION WITH THE SOIL REPORT.FOOTINGS ARE TO BE FOUNDED AT THE MINIMUM DEPTHS INDICATED IN THE SOIL REPORTOR MINIMUM 100 KPA SOIL CAPACITY.THE H.G.F.L. RECOMMENDS THAT FOOTINGS/SLABSAND DRAINAGE BE DESIGNED AND INSPECTED BY AN ENGINEER TO SATISFY THEIR REQUIREMENTS.
WHERE THE BUILDING (OTHER THAN A CLASS 10A) IS LOCATED IN A DESIGNATED TERMITE INFESTATION AREATHE BUILDING SHALL BE PROTECTED IN ACCORDANCE WITH THERELEVANT AUSTRALIAN STANDARDS.
WINDOW SIZES ARE NOMINAL ONLY. ACTUAL SIZES WILL VARY ACCORDING TO THE MANUFACTURER.WINDOWS ARE TO BE FLASHED ALL ROUND.
PROVIDE INSULATION AS PER PART J REPORT 3865 DESIGN AND DRAFTING BUILDING THERMAL ASSESMENTSTORM-WATER SHALL BE TAKEN TO THE LEGAL POINT OF DISCHARGETO THE SATISFACTION OF THE RELEVANT AUTHORITY
ALL DIMENSIONS RELEVANT TO SETTING OUT AND OFFSITE WORK SHALL BE VERIFIEDBY THE CONTRACTOR BEFORE CONSTRUCTION AND FABICATION IS COMMENCED
FOOTINGS ARE NOT TO ENCROACH ANY TITLE BOUNDARIES AND/OR EASEMENT LINES.
THE OWNER SHALL BE RESPONSIBLE FOR ENSURING THAT ALL SPECIFICATION ITEMS AND SIZES NOMINATED ARECORRECT AND DOCUMENTED TO THEIR REQUIREMENTS.THESE NOTES DO NOT REPLACE OR SUBSTITUTE ANY REGULATIONS, STATUTORY REQUIREMENTS AND/OR BUILDINGPRACTICE. THEY ARE PROVIDED ONLY AS GUIDELINES.THESE PLANS HAVE BEEN PREPARED FOR THE EXCLUSIVE USE BY THE CLIENT OF ANDREW DONOHUE ('THEDESIGNER') FOR THE PURPOSE EXPRESSLY NOTIFIED TO THE DESIGNER. ANY OTHER PERSON WHO USES OR RELIESON THESE PLANS WITHOUT THE DESIGNER'S WRITTEN CONSENT DOES SO AT THEIR OWN RISK AND NORESPONSIBILITY IS ACCEPTED BY THE DESIGNER FOR SUCH USE AND/OR RELIANCE.THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH ALL RELEVANT STRUCTURAL AND ALL OTHER CONSULTANTSDRAWINGS/DETAILS AND WITH ANY OTHER WRITTEN INSTRUCTIONS ISSUED IN THE COURSE OF THE CONTRACT.ALL MATERIALS AND WORK PRACTICES SHALL COMPLY WITH, BUT NOT LIMITED TO THE BUILDING REGULATIONS 2019,THE BUILDING CODE OF AUSTRALIA 2018 AND ALL RELEVANT CURRENT AUSTRALIAN STANDARDS (AS AMENDED)REFERRED TO THEREIN.ALL MATERIALS & CONSTRUCTION PRACTICE SHALL MEET THE PERFORMANCE REQUIREMENTS OF THE BCA. WHEREA PERFORMANCE SOLUTION IS PROPOSED THEN, PRIOR TO IMPLENTATION OR INSTALLATION, IT FIRST MUST BEASSESSED & APPROVED BY THE RELEVANT BUILDING SURVEYOR AS MEETING THE PERFORMANCE REQUIREMENTSOF THE BCAUNLESS OTHERWISE SPECIFIED, THE TERM BCA SHALL REFER TO NATIONAL CONSTRUCTION CODE SERIES 2019BUILDING CODE OF AUSTRALIA VOLUME 2FIGURED DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS.THE BUILDER SHALL TAKE ALL STEPS NECESSARY TO ENSURE THE STABILITY AND GENERAL WATER TIGHTNESS OF ALLNEW AND/OR EXISTING STRUCTURES DURING ALL WORKS.THE BUILDER AND SUBCONTRACTORS SHALL CHECK AND VERIFY ALL DIMENSIONS, SETBACKS, LEVELS ANDSPECIFICATIONS AND ALL OTHER RELEVANT DOCUMENTATION PRIOR TO THE COMMENCEMENT OF ANY WORKS.REPORT ALL DISCREPANCIES TO THIS OFFICE FOR CLARIFICATION.INSTALLATION OF ALL SERVICES SHALL COMPLY WITH THE RESPECTIVE SUPPLY AUTHORITY REQUIREMENTS.THE BUILDER AND SUBCONTRACTOR SHALL ENSURE THAT ALL STORMWATER DRAINS, SEWER PIPES AND THE LIKE ARELOCATED AT A SUFFICIENT DISTANCE FROM ANY BUILDINGS FOOTING AND/OR SLAB EDGE BEAMS SO AS TO PREVENTGENERAL MOISTURE PENETRATION, DAMPNESS, WEAKENING AND UNDERMINING OF ANY BUILDING AND ITSFOOTING SYSTEM.THE APPROVAL BY THIS OFFICE OF A SUBSTITUTE MATERIAL, WORK PRACTICE, VARIATION OR THE LIKE IS NOT ANAUTHORIZATION FOR ITS USE OR A CONTRACT VARIATION. ANY SAID VARIATIONS MUST BE ACCEPTED BY ALL PARTIESTO THE AGREEMENT AND WHERE APPLICABLE THE RELEVANT BUILDING SURVEYOR PRIOR TO IMPLEMENTING THESAID VARIATION.THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH ANY HOUSE ENERGY RATING (HERS) REPORT & SHALLBE CONSTRUCTEDIN ACCORDANCE WITH THE STAMPED PLANS ENDORSED BY THE ACCREDITED THERMALPERFORMANCE ASSESSOR WITHOUT ALTERATION.THE CLIENT AND/OR THE CLIENT'S BUILDER SHALL NOT MODIFY OR AMEND THE PLANS WITHOUT THE KNOWLEDGE &CONSENT OF ANDREW DONOHUE BUILDING DESIGN EXCEPT WHERE A REGISTERED BUILDING SURVEYOR MAKESMINOR NECESSARY CHANGES TO FACILITATE THE BUILDING PERMIT APPLICATION & THAT SUCH CHANGES AREPROMPTLY REPORTED BACK TO THIS OFFICE.A BUILDING PERMIT IS REQUIRED PRIOR TO THE COMMENCEMENT OF THESE WORKS. THE RELEASE OF THESEDOCUMENTS IS CONDITIONAL TO THE OWNER OBTAINING THE REQUIRED BUILDING PERMIT.
1 : 100
A3 DWG AM 10 -20
ANN OSBORNE1/130 FINLAY STCOWES
LOT AND PLAN NUMBER: LOT 1 PS541469ADDRESS: 985 LOCH-WONTHAGGI ROAD KROWERA 3945STANDARD PARCEL IDENTIFIER (SPI): 1\PS541469LOCAL GOVERNMENT (COUNCIL): BASS COASTCOUNCIL PROPERTY NUMBER: 29748 (PART)DIRECTORY REFERENCE:VICROADS 96 C9
SITE
6 NOVEMBER 20GENERAL NOTES
GLAZINGGLAZING INCLUDING SAFETY GLAZING SHALL BE INSTALLED TO A SIZE, TYPE AND THICKNESS SO AS TO COMPLYWITH:-BCA PART 3.6 FOR CLASS 1 AND 10 BUILDINGS WITHIN A DESIGN WIND SPEED OF NOT MORE THAN N3, AND-NCC 2019 BCA VOL 1 PART B1.4 FOR CLASS 2 TO 9 BUILDINGSWINDOW SIZES NOMINATED ARE NOMINAL. ACTUAL SIZE MAY VARY ACCORDING TO MANUFACTURE. WINDOWS TOBE FLASHED ALL AROUND
WET AREASWATERPROOFING OF WET AREAS, BEING BATHROOMS, SHOWERS, SHOWER ROOMS, LAUNDRIES, SANITARYCOMPARTMENTS AND THE LIKE SHALL BE PROVIDED IN ACCORDANCE WITH AS 3740-2010: WATERPROOFING OFWET AREAS IN RESIDENTIAL BUILDINGS.
PLUMBINGALL PLUMBING AND DRAINAGE WORKS TO BE IN ACC. WITH THE RELEVANT PLUMBING & DRAINAGE REGULATIONS,THE BUILDING CODE OF AUSTRALIA - 2005 AND WITH THE BY-LAWS OF LOCAL AUTHORITIES AND ALL OTHER RELEVANTCURRENT AUSTRALIAN STANDARDS REFERRED TO THEREIN.DOWNPIPES AND GUTTERS SHALL BE OF A SIZE AND LOCATION INDICATED ON THE DRAWINGS AND IF NOTSPECIFICALLY NOTES COMPLY WITH PART 3.5.2. DOWNPIPES SHALL BE LOCATED AT A MAXIMUM SPACING OF12M AND WITHIN 1.2M OF A VALLEY (UNLESS AN OVERFLOW IS PROVIDED)
STAIR & BALUSTRADE REQUIREMENTSRISERS (R)- 190MM MAXIMUM, 115MM MINIMUM;GOING (G)- 355MM MAXIMUM, 240MM MINIMUM;2R + 1G = 700MM MAXIMUM AND 550MM MINIMUM;125MM MAXIMUM GAP TO OPEN TREADS FROM 1 METER ABOVE GROUND LEVEL.WHERE A DECK IS LESS THAN 1 METRE RISER OPENING SHALL BE IN ACC. WITH PERFORMANCE REQUIREMENTP.2.5.1 (B) (III), "SUITABLE FOR SAFE PASSAGE".PROVIDE CONTINUOUS HANDRAIL 1000MM MINIMUM HEIGHT TO BALCONIES AND DECKS WHICH ARE 1000MMOR MORE ABOVE GROUND LEVEL. 865MM MINIMUM HEIGHT HANDRAIL ABOVE STAIR NOSING'S AND LANDINGS.ANY HORIZONTAL ELEMENT WITHIN THE BALUSTRADE BETWEEN 150MM AND 760MM ABOVE THE FLOOR MUSTNOT FACILITATE CLIMBING WHERE CHANGES IN LEVEL EXCEEDS 4000MM ABOVE THE SURFACE BENEATHLANDINGS, RAMPS AND/OR TREADSLANDINGS TO BE A MIN. 900X900 REQUIRED TO ANY DOOR WITH MORE THAN ONE STAIR RISE TO FLOOR LEVEL.MAXIMUM OPENINGS BETWEEN BALUSTERS NOT TO EXCEED 125MM. GENERALLY 240X45 F.7 TREATED PINESHALL BE USED FOR STRINGERS AND TREADS, 90X45 PINE FOR HANDRAIL AND BOTTOM RAIL. POSTS SHALL BE AT1500MM CTRS.ALL TREADS, LANDINGS AND THE LIKE TO HAVE A SLIP-RESISTANCE CLASSIFICATION OF P3 OR R10 FOR DRYSURFACECONDITIONS & P4 OR R11 FOR WET SURFACE CONDITIONS, OR A NOSING STRIP WOTH A SLIP-RESISTANCECLASSIFICATION OF P3 FOR DRY SURFACE CONDITIONS & P4 FOR WET SURFACE CONDITIONS.WIRE BALUSTRADE CONSTRUCTION TO COMPLY WITH NCC PART 3.9.2.3 FOR CLASS 1 AND 10 BUILDINGS ANDNCC 2019 BCA VOLUME 1 PART D2.16 FOR OTHER CLASSES OF BUILDINGS.
CONCRETE STUMPS- UP TO 1400MM LONG TO BE 100MM X 100MM (NO. 1 H.D WIRE)- 1401MM TO 1800MM LONG TO BE 100MM X 100MM (NO. 2 H.D WIRE)- 1801MM TO 3000MM LONG TO BE 125MM X 125MM (NO. 2 H.D WIRE)100MM X 100MM STUMPS EXCEEDING 1200MM ABOVE GROUND LEVEL TO BE BRACED WHERE NOPERIMETER BASE BRICKWORK PROVIDED.
MARINE OR OTHER EXPOSURE ENVIRONMENTSFOR BUILDINGS IN MARINE OR OTHER EXPOSURE ENVIRONMENTS SHALL HAVE MASONRY UNITS, MORTAR AND ALLBUILT IN COMPONENTS AND THE LIKE COMPLYING WITH DURABILITY REQUIREMENTS OF TABLE 4.1 OF AS 4773.1 -2010 'MASONRY IN SMALL BUILDINGS' PART 1 DESIGN.
SMOKE ALARMSSMOKE ALARMS ARE TO BE LOCATED AS INDICATED ON PLANS AND INSTALLED TO A.S 3786SMOKE DETECTORS SHALL BE HARD WIRED TO THE 240V SUPPLY SYSTEM WITH BATTERY BACKUP
SITE BUSHFIRE ATTACK ASSESSMENTBAL ATTACK LEVEL:-REFER TO BUSHFIRE ASSESSMENT FOR DETAILSSUBJECT SITE IS NOT IN A DESIGNATED BUSHFIRE PRONE AREA THEREFORE A BAL ASSESSMENT IS NOTREQUIREDSITE CLASSIFICATION- SITE CLASSIFICATION AS CLASS: CLASS 'M'- REFER TO SOIL REPORT NO: 20103- BY: DBM GEOTECHDESIGN GUST WIND SPEED / WIND CLASSIFICATIONBUILDING TIE-DOWNS TO BE PROVIDED IN ACCORDANCE WITH AS1684-2010 FOR AN ASSUMED DESIGNGUST WIND SPEED / WIND CLASSIFICATION OF N2 (SUBJECT TO CONFIRMATION ON SITE BY RELEVANTBUILDING SURVEYOR AT FIRST INSPECTION) REFER TO AS1684 FOR CONSTRUCTION REQUIREMENTS.STORMWATERALL STORMWATER TO BE TAKEN TO THE LEGAL POINT OF DISCHARGE TO THE RELEVANT AUTHORITES APPROVAL.90 MM DIA. CLASS 6 UPVC STORMWATER LINE LAID TO A MINIMUM GRADE OF 1:100 AND CONNECTEDTO THE LEGAL POINT OF STORMWATER DISCHARGE. PROVIDE INSPECTION OPENINGS AT 9000MM C/C ANDAT EACH CHANGE OF DIRECTION.THE COVER TO UNDERGROUND STORMWATER DRAINS SHALL BE NOT LESS THAN- 100MM UNDER SOIL- 50MM UNDER PAVED OR CONCRETE AREAS- 100MM UNDER UNREINFORCED CONCRETE OR PAVED DRIVEWAYS- 75MM UNDER REINFORCED CONCRETE DRIVEWAYSEARTHWORKSEARTHWORKS AND EXCAVATIONS SHALL BE AS REASONABLY NECESSARY TO FULFILL THE INTENT OF THEDESIGN. EXCAVATIONS BEYOND THE SCOPE OF THESE DRAWINGS OR IN THE PROXIMITY TO THE TITLEBOUNDARIES SHALL BE REFERRED TO THE RELEVANT BUILDING SURVEYOR FOR APPROVAL PRIOR TO THECOMMENCEMENT OF WORK.SITE IDENTIFICATIONPROVIDE A SITE SIGN INDICATING SITE ADDRESS, OWNER & BUILDERSITE MAINTENANCETHE BUILDER SHALL TAKE ALL STEPS NECESSARY TO MAINTAIN THE SITE IN A CLEAN & SAFE CONDITIONINCLUDING CONTAINMENT OF RUBBISH AND DISCHARGE. SANITARY FACILITIES ARE TO BE PROVIDED ON SITEFOR WORKMEN.CLIMATE ZONECLIMATE ZONE FOR THE THERMAL DESIGN/THERMAL PERFORMANCE ASSESSMENT : ZONE 6CORROSION PROTECTION FOR SHEET ROOFINGPROVIDE CORROSION PROTECTION FOR SHEET ROOFING IN ACCORDANCE WITH BCA TABLE 3.5.1.1ASUITABLE FOR AN ENVIRONMENT CLASSIFICATION
TO BE CONFIRMED BY ENERGY RATER PRELIMINARY ONLY
-R 3.5 INSULATION TO HOUSE CEILING-R 2.0 INSULATION TO ALL EXTERNAL WALLS-R 2.0 INSULATION TO TIMBER SUB-FLOOR-R 2.0 WALL BETWEEN GARAGE AND HOUSE-D.S.A.F. TO BE LAPPED AND TAPED AT JOINS AND ALL EXTERNAL OPENINGS- GLAZED ALUMINUM IMPROVED WINDOW FRAMESSLIDING - U-VALUE - SHGCAWNING - U-VALUE - SHGCSLIDING DOOR UNIT - U-VALUE - SHGC-2/10000L WATER TANK CONNECTED TO SANITARY FLUSHING SYSTEMS ORAN APPROVER HEAT PUMP HWS-ENCLOSE THE PERIMETER OF TIMBER SUB-FLOOR-ALL EXHAUST FANS IN HABITABLE ROOMS ARE REQUIRED TO BE FITTED WITH A SEALING DEVICESUCH AS A SELF CLOSING DAMPER (DRAFTSTOPPA DEVICE) OR FILTER.-SHEET LININGS OR EXPOSED BRICKWORK WITH CORNICE, ARCHITRAVES & SKIRTINGS SEALSAROUND WINDOW & DOOR OPENINGS-ALL DOWNLIGHT TO BE SEALED LED AND HAVE A MATRIX LOFT CONE COVER, OR SIMILARAPPROVED WHICH ALLOWS INSULATION TO INSTALLED UP AGENTS OR CLOSE TO COVERARTIFICIAL LIGHTING REQUIREMENTS:-MAXIMUM 5 WATTS PER SQ METRE OF LIVING FLOOR AREA-MAXIMUM 3 WATTS PER SQ METRE OF VERANDAH FLOOR AREA-MAXIMUM 4 WATTS PER SQ METRE OF GARAGE FLOOR AREA
GENERAL NOTES
1 OF 8
SITE LAYOUT
1 : 100
A3 DWG AM 10 -20
ANN OSBORNE1/130 FINLAY STCOWES
LOT AND PLAN NUMBER: LOT 1 PS541469ADDRESS: 985 LOCH-WONTHAGGI ROAD KROWERA 3945STANDARD PARCEL IDENTIFIER (SPI): 1\PS541469LOCAL GOVERNMENT (COUNCIL): BASS COASTCOUNCIL PROPERTY NUMBER: 29748 (PART)DIRECTORY REFERENCE:VICROADS 96 C9
SITE
6 NOVEMBER 20
ALL STORMWATER TO BE TAKEN TO THE LEGAL POINT OF DISCHARGE TO THE RELEVANT AUTHORITES APPROVAL.
INCLUDING CONTAINMENT OF RUBBISH AND DISCHARGE. SANITARY FACILITIES ARE TO BE PROVIDED ON SITE
AREA OF BLOCK 5732 M²PERMEABLE AREA 5321M² 92.3%IMPERMEABLE AREA HOUSE 303M²SHED AREA 108 M²COVERED AREA 411 M² 7.7%UN-COVERED AREA TRACKS GRAVEL APROX 300 M²
DWELLING AREA 164 M²STORE AREA 10 M²CARPORT AREA 24 M²BACK VERANDAH AREA 31 M²FRONT VERANDAH AREA UNDER ROOF 52 M²FRONT VERANDAH AREA OPEN 22 M²
TOTAL VERANDAH AREA 105 M²
TOTAL AREA 303 M²
PLANNING ZONES: PUBLIC USE ZONE - LOCAL GOVERNMENT (PUZ6)SCHEDULE TO THE PUBLIC USE ZONE - LOCAL GOVERNMENT (PUZ6)RURAL CONSERVATION ZONE (RCZ)SCHEDULE TO THE RURAL CONSERVATION ZONE (RCZ)PLANNING OVERLAYS: EROSION MANAGEMENT OVERLAY (EMO)EROSION MANAGEMENT OVERLAY - SCHEDULE 1 (EMO1)SIGNIFICANT LANDSCAPE OVERLAY (SLO)SIGNIFICANT LANDSCAPE OVERLAY - SCHEDULE 1 (SLO1
UTILITIESRURAL WATER CORPORATION: SOUTHERN RURAL WATERURBAN WATER CORPORATION: WESTERNPORT WATERMELBOURNE WATER: INSIDE DRAINAGE BOUNDARYPOWER DISTRIBUTOR: AUSNET
85340 mm
26980 mm
7447 mm
97340
mm
43530 mm
5556
0 m
m
PROPOSED SHED
12000 mm9000 m
m
R20000 mm
R20000 m
m
22311 mm
22710 m
m
10000 mm
10000
26000
OVER 100m
TO W
ATE
R C
OU
RSE
240 AHD
NEIGHBOURS DWELLING
EXISTING STABALISED CUT
REMOVE OBSOLETECRICKET PITCH
EXISTING CUT OFF DRAIN
EXISTING DRIVE
EXISTING CULVERT
PROPOSED DWELLING
Septic TankST 31003100 lt Tank
120 m Absorption Line
10000 L TANK
10000 L TANK
6000
3500
240 AHD240 AHD
240 AHD
239.800 AHD
239.600 AHD
239.600 AHD
240 AHD
240 AHD240 AHD
floor level 240.550 AHD
LOCALITY PLAN
GENERAL NOTES - SITE PLAN
2 OF 8
N
S
RISESET
SET RISE
WINTER SUN PATH
SUMMER SUN PATH
EXTENT OF NORTH FACING
BAL 12.5
R20
000 m
m
R20000 mm
AERIAL PLAN
ACCESS REQUIRED:• ALL-WEATHER CONSTRUCTION.• A LOAD LIMIT OF AT LEAST 15 TONNES.• PROVIDE A MINIMUM TRAFFICABLE WIDTH OF 3.5 METRES.• BE CLEAR OF ENCROACHMENTS FOR AT LEAST 0.5 METRES ON EACH SIDE AND AT LEAST 4 METRESVERTICALLY.• CURVES MUST HAVE A MINIMUM INNER RADIUS OF 10 METRES.• THE AVERAGE GRADE MUST BE NO MORE THAN 1 IN 7 (14.4%) (8.1°) WITH A MAXIMUM GRADE OF NOMORE THAN 1 IN 5 (20%) (11.3°) FOR NO MORE THAN 50 METRES.• DIPS MUST HAVE NO MORE THAN A 1 IN 8 (12.5%) (7.1°) ENTRY AND EXIT ANGLE.
WATER SUPPLY• AN EFFECTIVE CAPACITY OF 10000L VOLUME OF WATER LITRES.• BE STORED IN AN ABOVE GROUND WATER TANK CONSTRUCTED OF CONCRETE OR METAL.• HAVE ALL FIXED ABOVE GROUND WATER PIPES AND FITTINGS REQUIRED FOR FIREFIGHTING PURPOSES MADEOF CORROSIVE RESISTANT METAL.• INCLUDE A SEPARATE OUTLET FOR OCCUPANT USE.WHERE A 10,000 LITRE WATER SUPPLY IS REQUIRED, THE FOLLOWING FIRE AUTHORITY FITTINGS AND ACCESS MUSTBE PROVIDED:• BE READILY IDENTIFIABLE FROM THE BUILDING OR APPROPRIATE IDENTIFICATION SIGNAGE TO THESATISFACTION OF THE RELEVANT FIRE AUTHORITY.• BE LOCATED WITHIN 60 METRES OF THE OUTER EDGE OF THE APPROVED BUILDING.• THE OUTLET/S OF THE WATER TANK MUST BE WITHIN 4 METRES OF THE ACCESSWAY AND UNOBSTRUCTED.• INCORPORATE A SEPARATE BALL OR GATE VALVE (BRITISH STANDARD PIPE (BSP 65 MILLIMETRE) ANDCOUPLING (64 MILLIMETRE CFA 3 THREAD PER INCH MALE FITTING).• ANY PIPEWORK AND FITTINGS MUST BE A MINIMUM OF 65 MILLIMETRES (EXCLUDING THE CFA COUPLING).
1 : 1
00
A3
DW
G A
M 1
0 -
20
AN
N O
SB
OR
NE
1/1
30
FIN
LA
Y S
TC
OW
ES
LO
T A
ND
PLA
N N
UM
BE
R: LO
T 1
PS
541469
AD
DR
ES
S: 985 L
OC
H-W
ON
TH
AG
GI R
OA
D K
RO
WE
RA
3945
STA
ND
AR
D P
AR
CE
L ID
EN
TIF
IER
(S
PI)
: 1\P
S541469
LO
CA
L G
OV
ER
NM
EN
T (C
OU
NC
IL):
BA
SS
CO
AS
T
CO
UN
CIL
PR
OP
ER
TY
NU
MB
ER
: 29748 (P
AR
T)
DIR
EC
TO
RY
RE
FE
RE
NC
E:V
ICR
OA
DS
96 C
9
SIT
E
6 N
OV
EM
BE
R 2
0
Toiltet
Bathroom
Kitchen
Mud Room
Dining Room
Laundry
Master Bedroom
Living Room
Bedroom 2
Bedroom 3
Robe
Store Area
robe
Wa
lk in
pa
ntr
y
Walk in robe
3600 mm90 mm
9890 mm
90 mm
3600 mm
90 mm
3600 mm
90 mm
3600 mm
90 mm
3600 mm
90 mm
6200 mm
90 mm
3600 mm90 mm
17270 mm
90 mm
17450 mm
3600 m
m
90 m
m
600 m
m
90 m
m
90 m
m1500 m
m90 m
m5880 m
m90 m
m3600 m
m90 m
m
11340 m
m
3600 m
m
90 m
m
900 m
m
90 m
m
2100 m
m
90 m
m
600 m
m
90 m
m
3600 m
m
11160 m
m
11340 m
m1801 m
m
Car Port
Verandah
Verandah
90 mm
2310 mm
90 mm
1200 mm
1770 mm
90 mm
450 mm
90 mm
1200 mm
21
00
mm
4310 mm90 mm
1800 mm
1100 mm
90 mm
3000 m
m
90 m
m
4800 m
m
90 m
m
2580 m
m
90 m
m
3600 m
m
13760 mm 3690 mm
19741 m
m
6200 mm3600 mm
3390 m
m
17450 mm
7650 mm
3000 m
m
3600 m
m
19741 m
m
16140 m
m
1589 m
m
oven sinkdish
washer
island bench
Bathroom 2
2700 m
m90 m
m
6571 m
m
3179 m
m
90 m
m2700 m
m90 m
m
6570 m
m
3120 mm
6200 mm
A A
BB
BA
SE
PL
AN
3 O
F 8
N
S
RISE SET
SETRISE
WINTER SUN PATH
SUMMER SUN PATH
EXTENT OF NORTH FACING
CONSTRUCTION NOTES
DECK190 X 45 MGP 12 RAFTERS AT 900 CENT240 X 45 MGP LINTLE90 X90 MPG 12 POSTS100 X 35 TREATED PINE DECK90 X 45 MGP TREATED PINE FLOOR JOIST AT 450 CENTERS2/ 90 X 45 MGP BEARERS AT MAX1800 CENTERS100 X 100 CONCRETE STUMPS AT 1350 CENTERS300 DIA X 250 PADS FOUNDED ON VIRGIN SOIL MIN DEPTH 700PROVIDE WHITE ANT CAPS FOR PROTECTION
1 : 100
A3 DWG AM 10 -20
ANN OSBORNE1/130 FINLAY STCOWES
LOT AND PLAN NUMBER: LOT 1 PS541469ADDRESS: 985 LOCH-WONTHAGGI ROAD KROWERA 3945STANDARD PARCEL IDENTIFIER (SPI): 1\PS541469LOCAL GOVERNMENT (COUNCIL): BASS COASTCOUNCIL PROPERTY NUMBER: 29748 (PART)DIRECTORY REFERENCE:VICROADS 96 C9
SITE
6 NOVEMBER 20
COLOURBOND IRON 15 deg pitchtrusses to manufactures recomendations
COLOURBOND IRON 5 deg pitch
SELECTED WEATHER BOARD
SELECTED WEATHER BOARD
CARPORT SLAB RL 240.050
2100 m
m
2750 m
m
DECK RL 240.550
GROUNND LEVEL RL 240.000
COLOURBOND IRON 15 deg pitchtrusses to manufactures recomendations
SELECTED WEATHER BOARD
2750 m
m
GROUNND LEVEL RL 240.000
CONSTRUCTION NOTES
1. TO CONFORM TO LIGHT TIMBER FRAMING CODE2. BRACING TO CONFORM TO TIMBER FRAMING MANUAL3. WALL FRAMES DESIGNED & CONSTRUCTED INACCORDANCE WITH WIND LOADING AS SPECIFIEDWIND LOAD - N3WATERPROOFING OF WET AREAS, BEING BATHROOMS,SHOWERS, SHOWER ROOMS,LAUNDRIES,SANITARY COMPARTMENTS AND THE LIKE SHALL BE PROVIDEDIN ACCORDANCE WITH AS3740-2010: WATERPROOFING OF DOMESTIC WET AREAS.PROVIDE AN IMPERVIOUS SUBSTATE AND SELECT SURFACE FINISHTO FLOORS WITHIN 1500MM OF AN UNENCLOSED SHOWERAND SAME TO WALLS AT 1800MM ABOVE FLOORS AND 150MM ABOVEBATH, SINKS, BASINS AND TROUGH SPLASH BACKS AND THE LIKE.ENTIRE BATHROMM TO BE PROVIDED WITH WATER PROOF MEMBRANEINTERIOR LINING PLASTER:WALL - 10MM THICK PLASTERBOARD FIXED TO MANUFACTURERS SPECIFICATIONS,EXCEPT IN WET AREAS AQUA - CHECK PLASTEROR SIMILAR WATER PROOF MATERIAL SHALL BEINSTALLED IN SHOWER 1800MM HIGH MIN.ABOVE BASE,300MM ABOVE BATH RIM AND 300MM ABOVE VANITY UNIT.IN ACCORDANCE WITH NCC 2019CEILING -10MM THICK PLASTERBOARD THROUGHOUTFIXED TO MANUFACTURERS SPECIFICATIONSEXTERIOR FINISHSELECTED TIMBER
FRAMING SCHEDULE:DWELLINGCOLOURBOND IRON ROOF FITED TO MANUFACTURES RECOMENDATIONSTOP HAT SECTION OR 75 X 38 F8 HW BATTEN AT 900 CENTERSTRUSSES TO MANUFACTURES SPECIFICATIONMETAL TOP HAT PLASTER SECTION AT 450 CENTERS10 MM PLASTERBOARD TO CEILING AND WALLSPRIME WEATHR BOARD EXTERIORTOP AND BOTTOM PLATES: 2/90 X 45 MGP10 PINESTUDS: 90 X 35 MGP10 PINE NOT NOTCHED AT 450MM CTRS MAX.JAMB STUDS 90 X 45 MGP10STUDS AT SIDE OF OPENINGS:OPENINGS UP TO 900 90 X 45 MGP12 PINEOPENINGS UP TO 1800 2/90 X 35 MGP12 PINEOPENINGS UP TO 2400 2/90 X 45 MGP12 PINEOPENINGS UP TO 3000 2/90 X 45 MGP12 PINE19 MM YELLOW TOUNG CHIP BOARD FLOORING90 X 45 MGP TREATED PINE FLOOR JOIST AT 450 CENTERS2/ 90 X 45 MGP BEARERS AT MAX1800 CENTERS100 X 100 CONCRETE STUMPS AT 1350 CENTERS300 DIA X 250 PADS FOUNDED ON VIRGIN SOIL MIN DEPTH 700PROVIDE WHITE ANT CAPS FOR PROTECTIONCONCRETE FLOOR REFER CONCRETE PLANSTAIRS TO CONFORM TO NATIONAL CODE
NORTH ELEVATION
SOUTH ELEVATION
ELEVATIONS
4 OF 8
1 : 100
A3 DWG AM 10 -20
ANN OSBORNE1/130 FINLAY STCOWES
LOT AND PLAN NUMBER: LOT 1 PS541469ADDRESS: 985 LOCH-WONTHAGGI ROAD KROWERA 3945STANDARD PARCEL IDENTIFIER (SPI): 1\PS541469LOCAL GOVERNMENT (COUNCIL): BASS COASTCOUNCIL PROPERTY NUMBER: 29748 (PART)DIRECTORY REFERENCE:VICROADS 96 C9
SITE
6 NOVEMBER 20
COLOURBOND IRON 15 deg pitchtrusses to manufactures recomendations
SELECTED WEATHER BOARD
DECK RL 240.550
2100 m
m
2750 m
m
GROUNND LEVEL RL 240.000
2750 m
m
2100 m
m
COLOURBOND IRON 15 deg pitchtrusses to manufactures recomendations
COLOURBOND IRON 5 deg pitch
SELECTED WEATHER BOARD
SELECTED WEATHER BOARD
CEILING
5050 m
m
DECK RL 240.550
EAST ELEVATION
WEST ELEVATION
1. LEVELS RELATING TO GROUND LEVELS ARE APPROXIMATEONLY & ARE TO BE CHECKED & VERIFIED ON SITE BYTHE BUILDER PRIOR TO COMMENCEMENT OF ANYBUILDING WORKS. WRITTEN DIMENSIONS TAKEPRECEDENCE OVER SCALED DIMENSIONS.2. REQUIRED FILL & COMPACTION TO BE IN ACCORDANCEWITH A.S.2870-201125MM MAX STEP INTO EXTERNAL DOORS ALLOW FOR WHEEL CHAIR EASE OF ACESSGRADE PAVING AWAY FROM ENTERIESPROVIDE DOOR SEALS3. ALL WORKS INCLUDING BRICKS, BRICKWORK, CONCRETESLABS & FOOTINGS SHALL COMPLY WITH THEREQUIREMENTS OF THE RELEVANT AUSTRALIANSTANDARDS AS2870-20114 CONCRETE PAVING TO BE MIN 100MMVEHICHLE DRIVE TO BE 100MM WITH SL 62 MESH5 PROVIDE GRADED PAVING AWAY FROM RETAINING WALLWITH SLIGHT SPOON DRAIN FLOW TOWARD TTHE FRONT OF PROPERTY
OV
ER
LA
P T
O C
LA
DD
ING
HEAD FLASHING WITH
STOP-END EXTENDED TO
EDGE OF ALUMINIUM JAMB
FACINGS 20mm BEYOND
ALUMINIUM JAMB FACINGS
10 MM STOP-ENDS
50 m
m
15°
BALTIC PINE BEVEL BACKWEATHERBOARDS
WALL UNDERLAY TURNEDINTO FRAMING REVEAL ANDTAPED AT CORNERS
WALL UNDERLAY FLAPLAPPED OVER FLASHING
WEATHERBOARDSSHAPED TO SHED WATERWITH DRIP TO BOTTOMEDGE
DOWNTURN TO FLASHINGOVER-FOLDED TO FITTIGHT AGAINST ALUMINIUMHEAD FACING
AIRSEAL
INTENRALLINING
VENT STRIP
WINDOW FLASHING DETAIL
DIMENSION SILLTRAYS TO EXTENDFULL DEPTH OFALUMINIUMPROFILE
15
ALUMINIUM JOINERYPROFILE WITH 35mmFACINGS
SILL
WEATHERBOARDS
WALL UNDERLAYTURNED INTO FRAMINGREVEALS AND TAPED ATJOINTS
DO NOT SEAL GAPBETWEEN SILLSECTION AND TIMBERTRIM
PACKING AND WINDOWSUPPORT BRACKETSAS REQUIRED
INTERNAL LINING
FULL WIDTH LONG SILLTREY WITH 10mm STOP-ENDS (EACH END) ANDHOOK TO BACK EDGE
FULL WIDHT LONGSILL TRAY POSITIONSUNDER MULLIONSAND JAMBS - LAPUNDER JAMB PACKERAGAINST TRIMMINGSTUDS
HEAD CILL
CONSTRUCTION NOTES
90 X 45 MGP 12 TREATED PINE FLOOR JOIST AT 450 CENTERS2/ 90 X 45 MGP 12 BEARERS AT MAX1800 CENTERS100 X 100 CONCRETE STUMPS AT 1350 CENTERS MAX300 DIA X 250 PADS FOUNDED ON VIRGIN SOIL MIN DEPTH 700PROVIDE WHITE ANT CAPS FOR PROTECTION
290 X 45 F17 TIMBER STRINGERS240 X 38 F17 TIMBER TREADS240 X 19 F17 BACK CLOSURESTEP SIZES (OTHER THAN FOR SPIRAL STAIRS) TO BE:- RISERS (R) 190MM MAX AND 115MM MIN- GOING (G) 355MM MAX AND 240MM MIN- 2R + 1G = 700MM MAX AND 550MM MIN- WITH LESS THAN 125MM MAX GAP TO OPEN TREADS.FOR CLASS 1 AND 10 BUILDINGS ALL TREADS,LANDINGS AND THE LIKE TO HAVE NON-SLIP FINISH ORSUITABLE NON-SKID STRIP NEAR EDGE OF NOSING,AND FOR CLASS 2, 3 AND 4 ALL TREADS, LANDINGSAND THE LIKE TO HAVE A SLIP-RESISTANCECLASSIFICATION OF P3 OR R10 FOR DRY SURFACECONDITIONS AND P3 OR R11 FOR WET SURFACECONDITIONS, OR A NOSING STRIP WITH A SLIPRESISTANCECLASSIFICATION OF P3 FOR DRY SURFACECONDITIONS AND P4 FOR WET SURFACE CONDITIONSTOP OF HAND RAILS TO BE MINIMUM 865MMVERTICALLY ABOVE STAIR NOSING AND FLOOR SURFACEOF RAMPS.
STAIR DETAIL
DECK
GROUND
EVEN RISERSNOT GREATER THAN 190mm
240mm
ELEVATIONS
5 OF 8
1 : 100
A3 DWG AM 10 -20
ANN OSBORNE1/130 FINLAY STCOWES
LOT AND PLAN NUMBER: LOT 1 PS541469ADDRESS: 985 LOCH-WONTHAGGI ROAD KROWERA 3945STANDARD PARCEL IDENTIFIER (SPI): 1\PS541469LOCAL GOVERNMENT (COUNCIL): BASS COASTCOUNCIL PROPERTY NUMBER: 29748 (PART)DIRECTORY REFERENCE:VICROADS 96 C9
SITE
6 NOVEMBER 20
2700 m
m
700 m
m
CEILING
DECK RL 240.550FLOOR LEVEL RL 240.600
oven sinkdish
washer
45
0 m
m 100mm CONCRETE SLABF 52 MESH
PROVIDE POST STYRUP
450 mm 700
mm
DECK RL 240.550 FLOOR LEVEL RL 240.600
GROUNND LEVEL RL 240.000
SECTION AA
SECTION BB
SOIL CLASSIFICATIONMODERATE
1. ALL WORKS IN ACCORDANCE WITH AS2870.1 & AS36002. CONCRETE GRADES:-SLAB & FOOTINGS - 20MPA, MAX 20MM AGGREGATE & 80 SLUMPRETAINING WALL FOOTINGS - 25MPA, MAX 20MM AGGREGATE& 80 SLUMP3. ALL CONCRETE TO BE VIBRATED DURING PLACEMENT.4. ALL CONCRETE TO BE CURED IN AN APPROVED MANNER FOR A \MINIMUM OF 7 DAYS.5. MINIMUM REINFORCING LAPS:-HDWW11 - 500MMFABRIC - 2 CROSSRODS + 25MMN BARS - 40 X BAR DIATM - 500MM6. COVER TO REINFORCEMENTINTERNAL 30MMEXTERNAL 40MMGROUND 50MM7. ALL REINFORCEMENT IS TO BE FIRMLY SUPPORTIED ON PLASTIC,INSULATED STEEL OR CONVRETE BAR CHAIRS SPACED AT 1000C/CMAXIMUM.8. TILED AREAS TO HAVE BROOM FINISH, ELSEWHERE TO HAVE STEELTROWEL FINISH.9. CONCRETE SLAB & FOOTINGS HAVE BEEN DESIGNED TO SATISFY THEPERFORMANCE CRITERIA OF SECTION 3 OF AS2870 - RESIDENTIALSLABS & FOOTINGS.10. IN AREAS OF BRITTLE FLOOR COVERINGS EG SLATE OR TILES, ITWOULD BE RECOMMENDED THAT ONE OF THE FOLLOWING MEASURESBE UTILISED:-- INCRESE FABRIC SIZE TO SL92 OR DOUBLE MESH LAYER.- USE A RUBBERISED FLECIBLE ADHESIVE BEDDING- DELAY PLACING TILES FOR A MINIMUM OF 3 MONTHS11. PROVIDE CONTROL JOINTS TO EXTERNAL BRICK PERIMETER INACCORDANCE WITH THE BCA BUT NOT GREATER THAN 6M C/C, WITHIN1M OF CUT/FILL LINE, & AT VARIATIONS WITH FOOTING TYPE.12. THE OWNERS ATTENTION IS DRAWN TO CSIRO PAMPHLET "GUIDE TOHOME OWNER ON FOUNDTAION MAINTENANCE & FOOTINGPERFORMANCE". OWNER SHOULD COMPLY WITH THERECOMMENDATIONS OF THIS PAMPHLET. THE SITE ABOUT THEBUILDING PERIMETER & ALL SERVICE TRENCHES ARE TO BE GRADEDTO DRAIN AWAY FROM THE BUILDING PERIMETER.13. PROVIDE REPLACEMENT EQUIVALENT SIZED LAP BARS FRO ANYREINFORCEMENT THAT IS CUT DUE TO INSTALLATION OF SERVICES ETCTHROUGH SLAB BEAMS AND RIBS. REFER TO CONCRETE NOTES FORLAP LENGTHS.
SECTIONS
6 OF 8
450
mm 100mm CONCRETE SLAB
F 52 MESH
PROVIDE POST STYRUP
450 mm
1 : 100
A3 DWG AM 10 -20
ANN OSBORNE1/130 FINLAY STCOWES
LOT AND PLAN NUMBER: LOT 1 PS541469ADDRESS: 985 LOCH-WONTHAGGI ROAD KROWERA 3945STANDARD PARCEL IDENTIFIER (SPI): 1\PS541469LOCAL GOVERNMENT (COUNCIL): BASS COASTCOUNCIL PROPERTY NUMBER: 29748 (PART)DIRECTORY REFERENCE:VICROADS 96 C9
SITE
6 NOVEMBER 20
Toiltet
Bathroom
Kitchen
Mud Room
Dining Room
Laundry
Master Bedroom
Living Room
Bedroom 2
Bedroom 3
Robe
Store Area
robe
Walk
in
pantr
y
Walk in robe
Car Port
Verandah
Verandah
oven sinkdish
washer
island bench
Bathroom 2
Door ScheduleMark Size Description Count Notes
1 2040 mm X 1800 mm 2040 x 1800 Sliding Glass Door 1
2 2040 mm X 1829 mm 1829mm Sliding Door 1
3 2040 mm X 820 mm 820mm Slider - Cavity 6
4 2040 mm X 820 mm 820mm Hinged Door 5
5 2032 mm X 1829 mm 1829mm Sliding Glass Door 1
6 2032 mm X 1524 mm 1524mm Sliding Glass Door 1
7 2040 mm X 3000 mm 2040 x 3000 Sliding Glass Door 1
8 2032 mm X 1524 mm 1524 mm Pocket Door 1
9 2040 mm X 920 mm 920mm Slider - Cavity 1
1
2
3
3
4
5 6
4
7
4
3
8
4
3
33
9
4
Window ScheduleMark Size Description wind capacity N3 Count Notes
1 1200 mm X 1810 mm 1800mm x 1810mm Sliding Window 1
2 1200 mm X 1810 mm 1800mm x 1810mm Sliding Window 1
3 600 mm X 610 mm 600mm x 610mm Sliding Window 1
4 900 mm X 2410 mm 900mm x 2410mm Sliding Window 1
5 1200 mm X 1810 mm 1800mm x 1810mm Sliding Window highligh 1
6 1200 mm X 1810 mm 1800mm x 1810mm Sliding Window 1
7 1200 mm X 910 mm 1800mm x 910mm Sliding Window 1
8 1200 mm X 1810 mm 1800mm x 1810mm Sliding Window 1
9 600 mm X 1200 mm 600mm x 1200mm Sliding Window 1
10 900 mm X 2100 mm 900mm x 2100mm Sliding Window 1
11 900 mm X 610 mm 900mm x 610mm Sliding Window 1
1
2
3
4
5
6
7
8
9
10
11
window specific highligh
Aluminium
Aluminium
Aluminium
Aluminium
Aluminium
Aluminium
Aluminium
Aluminium
Aluminium
Aluminium
Aluminium
6570 m
m6571 m
m
3690 mm
1589 m
m
1800 m
m11
340 m
m
19741 m
m
16140 m
m3600 m
m
3000 m
m
3390 m
m
17450 mm
3600 mm 6200 mm 7650 mm
17450 mm
3690 mm13760 mm
CONSTRUCTION NOTES
90 X 45 MGP 12 TREATED PINE FLOOR JOIST AT 450 CENTERS2/ 90 X 45 MGP 12 BEARERS AT MAX1800 CENTERS100 X 100 CONCRETE STUMPS AT 1350 CENTERS MAX300 DIA X 250 PADS FOUNDED ON VIRGIN SOIL MIN DEPTH 700PROVIDE WHITE ANT CAPS FOR PROTECTION
290 X 45 F17 TIMBER STRINGERS240 X 38 F17 TIMBER TREADS240 X 19 F17 BACK CLOSURESTEP SIZES (OTHER THAN FOR SPIRAL STAIRS) TO BE:- RISERS (R) 190MM MAX AND 115MM MIN- GOING (G) 355MM MAX AND 240MM MIN- 2R + 1G = 700MM MAX AND 550MM MIN- WITH LESS THAN 125MM MAX GAP TO OPEN TREADS.FOR CLASS 1 AND 10 BUILDINGS ALL TREADS,LANDINGS AND THE LIKE TO HAVE NON-SLIP FINISH ORSUITABLE NON-SKID STRIP NEAR EDGE OF NOSING,AND FOR CLASS 2, 3 AND 4 ALL TREADS, LANDINGSAND THE LIKE TO HAVE A SLIP-RESISTANCECLASSIFICATION OF P3 OR R10 FOR DRY SURFACECONDITIONS AND P3 OR R11 FOR WET SURFACECONDITIONS, OR A NOSING STRIP WITH A SLIPRESISTANCECLASSIFICATION OF P3 FOR DRY SURFACECONDITIONS AND P4 FOR WET SURFACE CONDITIONSTOP OF HAND RAILS TO BE MINIMUM 865MMVERTICALLY ABOVE STAIR NOSING AND FLOOR SURFACEOF RAMPS.
SUB FLOOR LAYOUT
WINDOW /DOOR LAYOUT
2
DETAILS
7 OF 8
1 : 100
A3 DWG AM 10 -20
ANN OSBORNE1/130 FINLAY STCOWES
LOT AND PLAN NUMBER: LOT 1 PS541469ADDRESS: 985 LOCH-WONTHAGGI ROAD KROWERA 3945STANDARD PARCEL IDENTIFIER (SPI): 1\PS541469LOCAL GOVERNMENT (COUNCIL): BASS COASTCOUNCIL PROPERTY NUMBER: 29748 (PART)DIRECTORY REFERENCE:VICROADS 96 C9
SITE
6 NOVEMBER 20
2
STORM WATER EROSION CONTROL
8 OF 8
85340 mm
26980 mm
7447 mm
9734
0 mm
43530 mm
5556
0 m
m
PROPOSED SHED
12000 mm
9000 m
m
R20000 mm
R20000 m
m
22311 mm
22710 m
m
10000 mm
10000
26000
OVER 100m
TO W
ATER
CO
URSE
240 AHD
NEIGHBOURS DWELLING
EXISTING STABALISED CUT
REMOVE OBSOLETECRICKET PITCH
EXISTING CUT OFF DRAIN
EXISTING DRIVE
EXISTING CULVERT
PROPOSED DWELLING
Septic TankST 31003100 lt Tank
120 m Absorption Line
10000 L TANK
10000 L TANK
6000
3500
240 AHD240 AHD
240 AHD
239.800 AHD
239.600 AHD
239.600 AHD
240 AHD
240 AHD240 AHD
floor level 240.550 AHD
RISK ASSESSMENT
LOW RISK MINOR EXCAVATION
THE GENERAL CONDITION OF THE PROPERTY IS AN ESTABLISHED BENCHED SITETHE AREA HAS BEEN STABILISED OVER A NUMBER OF PRECEDING YEARSTHE CUT AHS BEEN RE ESTABLISHED AND HAS LARGE TREES GROWING ON FACE AS WELL AS GRASSESTHE PROPOSAL IS NOT TO DISTURBED
THERE IS AN EXISTING ESTABLISHED CUT OF DRAINIT IS NOT PROPOSED TO DISTURBED THE EXISTING DRAIN
THE CONSTRUCTION IS MINIMAL INVASION WITH STUMP AND BEARER CONSTRUCTION
THE MAIN CONSTRAINT IS THE CONSTRUCTION OF ABSORPTION SEPTIC FIELD
PREVENTION
ALL CUT OF DRAINS THAT MAY BE IMPACTED BY MINOR WORKSTO BE DIRECTED TO ONE COLLECTION POINT
SMALL DETENTION DAM CREATED FOR SEDIMENTCOLLECTION AS REQUIREDDAM OVER FLOW DRAIN TO BE PROVIDED WITH HAY BALESAND SECURED WITH STAR POSTS TO PREVENT ANY SEDIMENT OVER FLOW
RESPONSE
BUILDER/OWNER TO MONITOR ALL RUN OFF AND PREVENTANY IMPACT FROM SEDIMENT ON NEIGHBORING PROPERTIES
PERSONS IN CHARGE NEED TO MAKE THEM SELVESAWARE OF THE REQUIREMENTS OF TO EPA EROSION AND SEDIMENT ADVICE1300 372 842 (1300 EPA VIC)HTTPS://WWW.EPA.VIC.GOV.AU/FOR-BUSINESS/FIND-A-TOPIC/EROSION-AND-SEDIMENT/ADVICE-FOR-BUSINESSESBEST PRACTICE ENVIRONMENTAL MANAGEMENT SERIES; EROSION AND SEDIMENTATION
SHALLOW CUT OF DRAIN
DAM
HAY BALE COLLECTION
NOTE EXCAVATION WORK
EXCAVATION WORK IS LIMITED TO CONSTRUCTION AND SEPTIC WORKSNO BENCHING OT MAJOR FILL IS ENVISAGEDNO NATIVE VEGETATION IS TO BE REMOVEDTHE CONSTRUCTION IS ON A FLAT SIGHT WHERE THE AREA HASBEEN STABALISED FOR EXTENDED PERIOD OF TIMEGENERAL CONSTRUCTION RISK MANAGMENT IS AS DOCUMENTED ELSWHEREON THIS PAGE