2
Microscope Digital Camera DP21 DP21 system diagram USB memory Display Desktop PC Laptop PC Display cable Camera cable DP21 Camera head Handset Control unit DP2-TWAIN Software cellSens Optional Software IEEE1394a cable (9pin 6pin) IEEE1394a cable (9pin 4pin) DP21 laptop PC system DP21 desktop PC system C-mount camera adapter DP21 standalone system Microscope AC adapter Power cord Power cord DP21 System requirements* for DP2-TWAIN, cellSens PC Memory HDD Display Drive IEEE1394a cable PC input device OS OS language Web browser Intel Pentium 4, Intel Xeon, or Intel Core Duo (or equivalent) Windows Vista: 2 GB (3 GB recommended), Windows XP: 1024 MB RAM Free space of 1 GB or more (at the time of installation) 1280 x 1024 recommended (1024 x 768 or larger), 32-bit video card CD-ROM drive 1394a port x 1 6-pin IEEE1394a port for desktop PC system 4-pin IEEE1394a port for laptop PC system (AC adapter connection required to camera head) Two-button mouse or Three-button mouse (with scroll wheel recommended), keyboard Windows Vista Ultimate 32bit SP2, Windows Vista Business 32bit SP2, Windows XP (SP3 or later) Japanese, English IE6.0 or later *Please refer to our website for the applicable PCs. DP21 dimensions (unit: mm) 102 200 24 Handset Handset Camera head Camera head Control unit Control unit 90 47 With the use of a stabilizer 102 ø77 45.5 84 54.5 15.8 27.5 ø43.2 42.5 10.5 24.5 180 47 189 AC adapter DP21 specifications Type Imaging sensor Image size File format Image display Storage media Mount Sensitivity Metering modes Exposure control Exposure time Image display speed (frame rate) Input/output Scale display Measuring functions Size Effective pixels Scanning method Color filter Recording range Maximum recorded pixels Recorded pixels Video recording pixels Resolution Live image display Reproductive image display C-mount CCD camera head with control unit and handset 1/1.8 inch color CCD 2.01 megapixels ( total: 2.11 megapixels ) Progressive scan RGB Bayer primary color filter 7.04 (H) x 5.28 (V) mm, 8.8 mm (diagonal length) 1.92 megapixels (1600 x 1200) TIFF | TIFF | 1600 x 1200 | 5760 kB SHQ | JPEG | 1600 x 1200 | Approx. 2140 kB or less HQ | JPEG | 1600 x 1200 | Approx. 720 kB or less SQ-L | JPEG | 800 x 600 | Approx. 535 kB or less SQ-H | JPEG | 800 x 600 | Approx. 180 kB or less AVI | 400 x 300 WUXGA | 1920 x 1200 (display area 1600 x 1200) WSXGA | 1680 x 1050 (display area 1280 x 960) WSXGA | 1280 x 854 (display area 1024 x 768) WXGA | 1280 x 768 (display area 1024 x 768) WSVGA | 1024 x 600 (display area 800 x 600) UXGA | 1600 x 1200 SXGA | 1280 x 1024 (display area 1280 x 960) SXGA | 1280 x 960 XGA | 1024 x 768 SVGA | 800 x 600 USB memory, network PC C-mount Equivalent to ISO 100/200/400 1% center (spot), 30% center (average) AUTO/MANUAL AE lock: Possible only during Auto Exposure Exposure correction: ±2 EV in 1/3 EV steps, possible only during Auto Exposure AUTO: 2 to 1/20,000 sec. MANUAL: 8 to 1/20,000 sec. Rate: 15 frames per second (resolution: 1600 x 1200) 27 frames per second (resolution: 800 x 600) Magnifications: 1x, 2x (electric zoom) and 4x (electric zoom) Index display, magnifications 1x, 2x and 4x DC input Camera I/O: IEEE1394b I/F: USB 2.0 Display output: DVI-I (digital/analog RGB) Wired LAN: 100Base-TX/10Base-T Serial port: RS-232C D-SUB 9-pin View scale/Hide scale Available microscope total magnification: 0.01x to 9999.99x *Up to 8 total magnifications can be set Distance of 2 Points, 3 Points Circle, Distance between 2 Circle Centers, 3 Points Angle, 4 Points Angle, Perpendiculars, Polygon Area, Boundary Length, Distance of Parallel Lines, XY Distance, Count, Poly Line, and Cross Line • OLYMPUS CORPORATION is ISO14001 certified. • OLYMPUS CORPORATION is FM553994/ISO9001 certified. • Windows is a registered trademark of Microsoft Corporation in the United States and other countries. All other company and product names are registered trademarks and/or trademarks of their respective owners. • Images on the PC monitors are simulated. • Specifications and appearances are subject to change without any notice or obligation on the part of the manufacturer. Printed in Japan M1685E-0610B

Upload: duonghuong

Post on 02-Apr-2018

218 views

Category:

Documents


0 download

TRANSCRIPT

Microscope Digital Camera

DP21

DP21 system diagram

USB memory

Display

Desktop PC

Laptop PC

Display cable

Camera cable

DP21Camera head

Handset

Control unit

DP2-TWAINSoftware

cellSensOptional Software

IEEE1394a cable(9pin ↔ 6pin)

IEEE1394a cable(9pin ↔ 4pin)

DP21 laptop PC system

DP21 desktop PC system

C-mount camera adapter

DP21 standalonesystem

Microscope

AC adapter Power cord

Power cord

DP21

System requirements* for DP2-TWAIN, cellSens PCMemoryHDDDisplayDriveIEEE1394acable

PC input deviceOSOS languageWeb browser

Intel Pentium 4, Intel Xeon, or Intel Core Duo (or equivalent)Windows Vista: 2 GB (3 GB recommended), Windows XP: 1024 MB RAMFree space of 1 GB or more (at the time of installation)1280 x 1024 recommended (1024 x 768 or larger), 32-bit video cardCD-ROM drive1394a port x 16-pin IEEE1394a port for desktop PC system 4-pin IEEE1394a port for laptop PC system (AC adapter connection required to camera head)Two-button mouse or Three-button mouse (with scroll wheel recommended), keyboardWindows Vista Ultimate 32bit SP2, Windows Vista Business 32bit SP2, Windows XP (SP3 or later)Japanese, EnglishIE6.0 or later

*Please refer to our website for the applicable PCs.

DP21 dimensions (unit: mm)

102

200

24

HandsetHandsetCamera headCamera head Control unitControl unit

90

47

With the use of a stabilizer

102

ø77

45.5

84

54.5

15.8

27.5

ø43.2

42.5

10.5

24.5

180

47

189

AC adapter

DP21 specificationsTypeImaging sensor

Image size File format

Image display

Storage mediaMountSensitivity Metering modes Exposure control

Exposure time

Image display speed (frame rate)

Input/output

Scale display

Measuring functions

SizeEffective pixelsScanning method Color filterRecording range Maximum recorded pixelsRecorded pixels

Video recording pixelsResolution

Live image display

Reproductive image display

C-mount CCD camera head with control unit and handset1/1.8 inch color CCD2.01 megapixels ( total: 2.11 megapixels )Progressive scanRGB Bayer primary color filter7.04 (H) x 5.28 (V) mm, 8.8 mm (diagonal length)1.92 megapixels (1600 x 1200)TIFF | TIFF | 1600 x 1200 | 5760 kBSHQ | JPEG | 1600 x 1200 | Approx. 2140 kB or lessHQ | JPEG | 1600 x 1200 | Approx. 720 kB or lessSQ-L | JPEG | 800 x 600 | Approx. 535 kB or lessSQ-H | JPEG | 800 x 600 | Approx. 180 kB or lessAVI | 400 x 300WUXGA | 1920 x 1200 (display area 1600 x 1200) WSXGA | 1680 x 1050 (display area 1280 x 960)WSXGA | 1280 x 854 (display area 1024 x 768)WXGA | 1280 x 768 (display area 1024 x 768)WSVGA | 1024 x 600 (display area 800 x 600)UXGA | 1600 x 1200SXGA | 1280 x 1024 (display area 1280 x 960)SXGA | 1280 x 960XGA | 1024 x 768SVGA | 800 x 600USB memory, network PCC-mountEquivalent to ISO 100/200/4001% center (spot), 30% center (average)AUTO/MANUALAE lock: Possible only during Auto ExposureExposure correction: ±2 EV in 1/3 EV steps, possible only during Auto Exposure AUTO: 2 to 1/20,000 sec.MANUAL: 8 to 1/20,000 sec.Rate: 15 frames per second (resolution: 1600 x 1200) 27 frames per second (resolution: 800 x 600)Magnifications: 1x, 2x (electric zoom) and 4x (electric zoom)Index display, magnifications 1x, 2x and 4xDC inputCamera I/O: IEEE1394bI/F: USB 2.0Display output: DVI-I (digital/analog RGB)Wired LAN: 100Base-TX/10Base-TSerial port: RS-232C D-SUB 9-pinView scale/Hide scaleAvailable microscope total magnification: 0.01x to 9999.99x*Up to 8 total magnifications can be setDistance of 2 Points, 3 Points Circle, Distance between 2 Circle Centers, 3 Points Angle, 4 Points Angle, Perpendiculars, Polygon Area, Boundary Length, Distance of Parallel Lines, XY Distance, Count, Poly Line, and Cross Line

• OLYMPUS CORPORATION is ISO14001 certified.• OLYMPUS CORPORATION is FM553994/ISO9001 certified.• Windows is a registered trademark of Microsoft Corporation in the United States and other countries. All other company and product names are registered trademarks and/or trademarks of their respective owners.• Images on the PC monitors are simulated.• Specifications and appearances are subject to change without any notice or obligation on the part of the manufacturer.

Printed in Japan M1685E-0610B