DRIP IRRIGATIONSYSTEM
bybyAlbert Jarrett,Albert Jarrett,
Professor of BiologicalProfessor of Biological
EngineeringEngineeringPenn State UniversityPenn State University
-
8/9/2019 Drip Irrigation - Penn State University
2/71
3/19/2010
The Pennsylvania Protocol
In Chapter 73 (In Chapter 73 (ConventionalConventional).). InIn--Ground Systems (Limiting Zone >60 in).Ground Systems (Limiting Zone >60 in).
Beds.Beds.
Trenches.Trenches.
Subsurface Sand Filters.Subsurface Sand Filters. Elevated Sand Mounds (Limiting Zone >20 in).Elevated Sand Mounds (Limiting Zone >20 in).
Individual Residential Spray Irrigation SystemIndividual Residential Spray Irrigation System
Bedrock Limiting Zone > 16 in.Bedrock Limiting Zone > 16 in.
Water Table Limiting Zone >10 in.Water Table Limiting Zone >10 in.
-
8/9/2019 Drip Irrigation - Penn State University
3/71
Drip Irrigation Drip Irrigation is an Alternate OnDrip Irrigation is an Alternate On--LotLot
Disposal System.Disposal System.
The following slides present the dripThe following slides present the dripirrigation system concept in some detail.irrigation system concept in some detail.
This presentation ends with an exampleThis presentation ends with an example
that shows the design process.that shows the design process.
-
8/9/2019 Drip Irrigation - Penn State University
4/71
Soil Conditions:
Rock Limiting ZoneRock Limiting Zone 26 inches.26 inches.
Seasonal High Water Table LimitingSeasonal High Water Table Limiting
ZoneZone 20 inches.20 inches.
SlopeSlope 25% 25%..
26 inches 20 inches
-
8/9/2019 Drip Irrigation - Penn State University
5/71
Soil Conditions No Perc Test is required.No Perc Test is required.
Soil profile must beSoil profile must be
evaluated by a licensedevaluated by a licensedsoil scientist whosoil scientist who
evaluates the probes.evaluates the probes.
Soils must be wellSoils must be well
drained or moderatelydrained or moderatelywell drained.well drained.
-
8/9/2019 Drip Irrigation - Penn State University
6/71
-
8/9/2019 Drip Irrigation - Penn State University
7/71
Drip Irrigation
Overview w/ Aerobic Tank Major ComponentsMajor Components
Treatment Tank FiltrationHydraulic
Pump Tank
Hydraulic
Unit
Zones
-
8/9/2019 Drip Irrigation - Penn State University
8/71
Drip Irrigation
Overview w/ Sand Filter Major ComponentsMajor Components
Treatment TankFiltration
Hydraulic
Pump Tank
Hydraulic
Unit
Zones
-
8/9/2019 Drip Irrigation - Penn State University
9/71
Treatment Processes
From Home to Treatment Tank.From Home to Treatment Tank.
Septic TankSeptic Tank
Solids settleSolids settle
Scum floats to surfaceScum floats to surface
Two Chamber Septic TanksTwo Chamber Septic Tanks
required.required.
-
8/9/2019 Drip Irrigation - Penn State University
10/71
Treatment Tank
TwoTwo--Chamber Septic TankChamber Septic Tank
-
8/9/2019 Drip Irrigation - Penn State University
11/71
Treatment Processes
From the Treatment Tank to the FiltrationFrom the Treatment Tank to the Filtration
Unit.Unit.
Secondary Treatment is required ifSecondary Treatment is required if
Limiting Zone < 48 inches.Limiting Zone < 48 inches.
Aerobic Treatment TankAerobic Treatment Tank
Free Access Sand Filter (5 gal/d/ftFree Access Sand Filter (5 gal/d/ft22))
Subsurface Sand Filter (0.8 gal/d/ftSubsurface Sand Filter (0.8 gal/d/ft22))
-
8/9/2019 Drip Irrigation - Penn State University
12/71
Aerobic Treatment Tank
-
8/9/2019 Drip Irrigation - Penn State University
13/71
Free Access Sand Filter
(side view)
-
8/9/2019 Drip Irrigation - Penn State University
14/71
Free Access Sand Filter
(top view)
-
8/9/2019 Drip Irrigation - Penn State University
15/71
Subsurface Sand Filter
(partial side view)
-
8/9/2019 Drip Irrigation - Penn State University
16/71
-
8/9/2019 Drip Irrigation - Penn State University
17/71
Treatment Processes From the Filtration Unit to the Hydraulic UnitFrom the Filtration Unit to the Hydraulic Unit
to the Drip Zones.to the Drip Zones.
The filtered effluent flows, by gravity, intoThe filtered effluent flows, by gravity, intothe Hydraulic Unit Pump Tank:the Hydraulic Unit Pump Tank:
Here a series of float switches controlsHere a series of float switches controlsthe flow of partially treated wastewaterthe flow of partially treated wastewaterto the Hydraulic Unit.to the Hydraulic Unit.
The Hydraulic Unit is 2 (or 3) discThe Hydraulic Unit is 2 (or 3) discfilters that provide final filtrationfilters that provide final filtrationbefore application to the soil.before application to the soil.
-
8/9/2019 Drip Irrigation - Penn State University
18/71
Hydraulic Unit Pump Tank
Pump TankPump Tank
Receives Filter Unit effluentReceives Filter Unit effluent
Doses effluent to Hydraulic Unit and Zones.Doses effluent to Hydraulic Unit and Zones.
Contains pumpContains pump--control switches.control switches.
-
8/9/2019 Drip Irrigation - Penn State University
19/71
Hydraulic Unit Contains 2 (or 3)Contains 2 (or 3)
disc filters.disc filters.
Provides finalProvides finalfiltration beforefiltration before
going to dripgoing to drip
zones.zones.
Must have at leastMust have at least
2 zones.2 zones.
-
8/9/2019 Drip Irrigation - Penn State University
20/71
Drip Zones
-
8/9/2019 Drip Irrigation - Penn State University
21/71
Drip Zones Each long sectionEach long section
of a zone is on theof a zone is on thecontour.contour.
Each zone mayEach zone mayhave more thanhave more than
one lateral.one lateral. Each lateral mayEach lateral may
have more thanhave more thanone zone.one zone.
Each zone mustEach zone musthave a supply andhave a supply and
return line.return line. Air vents are alsoAir vents are also
required on eachrequired on eachzone.zone.
-
8/9/2019 Drip Irrigation - Penn State University
22/71
Drip System With Water LimitingWith Water Limiting
ZoneZone uu 20 inches.20 inches.
u 20 inchesEmitters spaced 2 feet
apart; 0.68 gal/d/em
0 to 12 in deep; 6 to 12 in
of cover over the tubing.
Maybe as small as 8 in
-
8/9/2019 Drip Irrigation - Penn State University
23/71
Drip System With Rock LimitingWith Rock Limiting
ZoneZone uu 26 inches.26 inches.
u 20 inchesEmitters spaced 2 feet
apart; 0.68 gal/d/em
0 to 12 in deep; 6 to 12 in
of cover over the tubing.
-
8/9/2019 Drip Irrigation - Penn State University
24/71
Drip System; 3rd
Configuration
With Rock Limiting ZoneWith Rock Limiting Zone uu 20 inches.20 inches.
u 20 inchesEmitters spaced 2 feet
apart; 0.65 gal/d/em
Driplines laid on soil
surface and covered
with native topsoil.
-
8/9/2019 Drip Irrigation - Penn State University
25/71
Simple Example A site, with a 3A site, with a 3--bdrm home, has a well drained soilbdrm home, has a well drained soil
with a rock limiting zone at 35 inches and a seasonalwith a rock limiting zone at 35 inches and a seasonalhigh watertable at 25 inches.high watertable at 25 inches.
The site has a 10% slope.The site has a 10% slope.
Soil Scientist report states:Soil Scientist report states:
Maximum soil linear load rate = 0.25 gal/ft/d.Maximum soil linear load rate = 0.25 gal/ft/d.
Horizontal linear load = 3.5 gal/ft/d.Horizontal linear load = 3.5 gal/ft/d.
Drip tubing spacing to be at least 2.0 feet.Drip tubing spacing to be at least 2.0 feet. Tubing to be buried at least 6 inches deep.Tubing to be buried at least 6 inches deep.
-
8/9/2019 Drip Irrigation - Penn State University
26/71
-
8/9/2019 Drip Irrigation - Penn State University
27/71
Soil Conditions:
Rock Limiting ZoneRock Limiting Zone == 35 inches.35 inches.
Seasonal High Water Table LimitingSeasonal High Water Table Limiting
ZoneZone == 25 inches.25 inches.
SlopeSlope = 10%= 10%..
= 35 inches
= 25 inches
-
8/9/2019 Drip Irrigation - Penn State University
28/71
Soil Conditions:
Rock Limiting ZoneRock Limiting Zone == 35 inches.35 inches.
= 35 inches
6 inches
29 inches
-
8/9/2019 Drip Irrigation - Penn State University
29/71
Soil Conditions:
Seasonal High Water Table LimitingSeasonal High Water Table Limiting
ZoneZone == 25 inches.25 inches.
= 25 inches
6 inches
19 inches
-
8/9/2019 Drip Irrigation - Penn State University
30/71
Example Soil Scientists ReportSoil Scientists Report
Maximum linear loading rate = 0.25Maximum linear loading rate = 0.25
gal/d/ft.gal/d/ft.
Horizontal linear load = 3.5 gal/d/ftHorizontal linear load = 3.5 gal/d/ft
-
8/9/2019 Drip Irrigation - Penn State University
31/71
Example The septic tank is sized as per Chapter 73 forThe septic tank is sized as per Chapter 73 for
a 3 bdrm home.a 3 bdrm home.
This is a drip system, so a SecondaryThis is a drip system, so a SecondaryTreatment unit is needed. The choices are:Treatment unit is needed. The choices are:
Aerobic Treatment TankAerobic Treatment Tank
Free Access sand filter.Free Access sand filter.
Subsurface sand filter.Subsurface sand filter. See the Secondary Treatment slides forSee the Secondary Treatment slides for
sizing guidelines for these units.sizing guidelines for these units.
-
8/9/2019 Drip Irrigation - Penn State University
32/71
Example Following the PreFollowing the Pre--treatment unit the effluenttreatment unit the effluent
will flow into a Dose/Pump tank.will flow into a Dose/Pump tank.
-
8/9/2019 Drip Irrigation - Penn State University
33/71
Example The Pump/Dose Tank must be at leastThe Pump/Dose Tank must be at least
2 times larger than the maximum daily2 times larger than the maximum daily
flow.flow.
The maximum daily flow from a 3The maximum daily flow from a 3--bdrmbdrm
home is taken to be 400 gpd.home is taken to be 400 gpd.
Therefore the Pump/Dose Tank must beTherefore the Pump/Dose Tank must beat least 800 gallons in size.at least 800 gallons in size.
-
8/9/2019 Drip Irrigation - Penn State University
34/71
Example In a Drip Irrigation system the effluent isIn a Drip Irrigation system the effluent is
pumped from the Dose/Pump Tank to thepumped from the Dose/Pump Tank to the
Hydraulic Unit and on to the drip zones.Hydraulic Unit and on to the drip zones.
-
8/9/2019 Drip Irrigation - Penn State University
35/71
Example The Hydraulic Unit controls the flow toThe Hydraulic Unit controls the flow to
zones and backflushing. Two units arezones and backflushing. Two units are
available: 2available: 2--disc and 3disc and 3--disc units.disc units.The twoThe two--disc unit supports:disc unit supports:
1,200 ft of drip tubing/zone.1,200 ft of drip tubing/zone.
Tubing forward flush rate = 15 gpm.Tubing forward flush rate = 15 gpm.
4 zones and one return connection.4 zones and one return connection.
4,800 ft of drip tubing (4x1200).4,800 ft of drip tubing (4x1200).
-
8/9/2019 Drip Irrigation - Penn State University
36/71
-
8/9/2019 Drip Irrigation - Penn State University
37/71
Example Length of drip tubing required:Length of drip tubing required:
Max daily flow/linear loading rateMax daily flow/linear loading rate
400 gpd/0.25 gal/d400 gpd/0.25 gal/d--ft = 1600 ft.ft = 1600 ft.
We will use 2 zones.We will use 2 zones.
1600 ft/2 = 800 ft/zone1600 ft/2 = 800 ft/zone
-
8/9/2019 Drip Irrigation - Penn State University
38/71
Example Each zone will consist ofEach zone will consist of
8 runs of 100 ft each.8 runs of 100 ft each.
4 laterals, each 200 ft long. (24 laterals, each 200 ft long. (2
runs/lateral).runs/lateral).
Supply Line
Return line
Air Vent & Check Valve
Run
Lateral (4)
-
8/9/2019 Drip Irrigation - Penn State University
39/71
Example Check to make sure the runs are longCheck to make sure the runs are long
enough.enough.
Based on the Average daily flowBased on the Average daily flow
400 gpd (.5) = 200 gpd.400 gpd (.5) = 200 gpd.
Horizontal linear load = 3.5 gal/gHorizontal linear load = 3.5 gal/g--ftft
Minimum run length = 200/3.5 = 57 ft.Minimum run length = 200/3.5 = 57 ft.
Our runs are 100 ft long; Okay.Our runs are 100 ft long; Okay.
-
8/9/2019 Drip Irrigation - Penn State University
40/71
Example (Summary) Peak daily flow = 400 gpd.Peak daily flow = 400 gpd. Soil linear load = 0.25 gal/dSoil linear load = 0.25 gal/d--ft.ft.
Total tubing length required = 1600 ft.Total tubing length required = 1600 ft.
2 zones used.2 zones used.
Hydraulic Unit used = 2 disc.Hydraulic Unit used = 2 disc. Tubing length/zone = 1600/2 = 800 ft.Tubing length/zone = 1600/2 = 800 ft.
No. Laterals/zone = 4No. Laterals/zone = 4
Lateral length = 800/4 = 200 ft.Lateral length = 800/4 = 200 ft.
Run length = 100 ft.Run length = 100 ft. Horizontal linear load = 3.5 gal/dHorizontal linear load = 3.5 gal/d--ft.ft.
Minimum run length = 200/3.5 = 57 ft.Minimum run length = 200/3.5 = 57 ft.
-
8/9/2019 Drip Irrigation - Penn State University
41/71
Example Flow required to each zone duringFlow required to each zone during
Forward Field Flush HydraulicForward Field Flush Hydraulic
Condition.Condition.
Need:Need:
Dose flow rate PLUSDose flow rate PLUS
Field flush flow rateField flush flow rate
-
8/9/2019 Drip Irrigation - Penn State University
42/71
Example Dose flow rate (for each zone)=Dose flow rate (for each zone)=
hrgphx
nemittersdistbetweenelengthofzo
min/6065.0
gpmhr
gphxemittersft
ft 3.4min/6065.0
/2800 !
-
8/9/2019 Drip Irrigation - Penn State University
43/71
Example Field flush flow rate/zone = 1.6Field flush flow rate/zone = 1.6
gpm/lateral (to maintain a velocity of 2gpm/lateral (to maintain a velocity of 2
fps in drip tubes)fps in drip tubes)=1.6gpm/lat x 4 laterals = 6.4=1.6gpm/lat x 4 laterals = 6.4
gpm/zonegpm/zone
Total flow required during Forward FieldTotal flow required during Forward FieldFlush is 4.3 + 6.4 = 10.7 gpm.Flush is 4.3 + 6.4 = 10.7 gpm.
-
8/9/2019 Drip Irrigation - Penn State University
44/71
Example (Pump Selection) The remaining task is to size the pump.The remaining task is to size the pump.
This means that we must determine:This means that we must determine:
Systems total headSystems total head
Systems maximum flow rate.Systems maximum flow rate.
-
8/9/2019 Drip Irrigation - Penn State University
45/71
Example (Bernoulli Analysis) The Total Head for the pump in the DoseThe Total Head for the pump in the Dose
Tank is the sum of three components:Tank is the sum of three components:
Head Loss in all the pipes.Head Loss in all the pipes. Pressure needed to run the system, eitherPressure needed to run the system, either
the emitters or the Hydraulic Unit.the emitters or the Hydraulic Unit.
Elevation difference between the waterElevation difference between the waterlevel in the dose tank to the drip zones.level in the dose tank to the drip zones.
The Total Head is the SUM of these threeThe Total Head is the SUM of these threevalues.values.
-
8/9/2019 Drip Irrigation - Penn State University
46/71
Example (Friction; HL) The Head Loss (or Friction) is the mostThe Head Loss (or Friction) is the most
difficult to determine. This must be donedifficult to determine. This must be done
in parts:in parts:HHLL in the pipe from the dose tank toin the pipe from the dose tank to
the Hydraulic Unit.the Hydraulic Unit.
HHLL in the Zone supply pipes.in the Zone supply pipes.
HHLL in the drip lines.in the drip lines.
HHLL in the Zone return pipes.in the Zone return pipes.
-
8/9/2019 Drip Irrigation - Penn State University
47/71
Example (HL from tank to HU) First size this pipe to carry theFirst size this pipe to carry the
maximum flow.maximum flow.
During dosing the pipe will carry 10.7During dosing the pipe will carry 10.7
gpm.gpm.
During back flushing this pipe will carryDuring back flushing this pipe will carry
15 gpm.15 gpm. Size for theSize for the 15 gpm15 gpm..
-
8/9/2019 Drip Irrigation - Penn State University
48/71
Example (Size the pipe to HU) With a design flow rate of 15 gpm andWith a design flow rate of 15 gpm and
using PVCusing PVC--scheduleschedule--40 pipe, we will40 pipe, we will
need a 1.5need a 1.5--inch pipe to keep theinch pipe to keep thevelocity above 2.0 fps. (V = 2.35 fps).velocity above 2.0 fps. (V = 2.35 fps).
This 1.5This 1.5--in PVC pipe has a frictionin PVC pipe has a friction
factor, Ffactor, Fcc = 0.63 psi/100 ft or 1.46 ft/100= 0.63 psi/100 ft or 1.46 ft/100ft.ft.
-
8/9/2019 Drip Irrigation - Penn State University
49/71
-
8/9/2019 Drip Irrigation - Penn State University
50/71
Example (HL from tank to HU) The HThe HLL is calculated from:is calculated from:
HHLL = F= FccLL
HHLL = 1.46 ft/100 ft(70ft) = 1.02 ft.= 1.46 ft/100 ft(70ft) = 1.02 ft.
-
8/9/2019 Drip Irrigation - Penn State University
51/71
Example (HL in Supply Pipe) First size the Supply pipe to carry theFirst size the Supply pipe to carry the
maximum flow.maximum flow.
During dosing the pipe will carry 10.7During dosing the pipe will carry 10.7gpm.gpm.
Not used during back flushing.Not used during back flushing.
Size for theSize for the 10.7 gpm10.7 gpm..
-
8/9/2019 Drip Irrigation - Penn State University
52/71
-
8/9/2019 Drip Irrigation - Penn State University
53/71
Example (HL in Supply Pipe) Before we can determine the HBefore we can determine the HLL in thisin this
pipe, we must determine the length ofpipe, we must determine the length of
the supply pipe [this is assumed to be athe supply pipe [this is assumed to be astraight pipe].straight pipe].
The length of pipe was given at 100The length of pipe was given at 100
ft.ft.
-
8/9/2019 Drip Irrigation - Penn State University
54/71
Example (HL in Supply Pipe) The HThe HLL is calculated from:is calculated from:
HHLL = F= FccLL
HHLL = 1.62 ft/100 ft(100ft) = 1.62 ft.= 1.62 ft/100 ft(100ft) = 1.62 ft.
-
8/9/2019 Drip Irrigation - Penn State University
55/71
Example (HL inD
rip Zone) We desire to deliver 10.7 gpm to eachWe desire to deliver 10.7 gpm to each
zone. Of this water:zone. Of this water:
4.3 gpm will go out the emitters.4.3 gpm will go out the emitters.
6.4 gpm will flush through the drip6.4 gpm will flush through the drip
lines and be returned to the buildinglines and be returned to the building
sewer.sewer.
-
8/9/2019 Drip Irrigation - Penn State University
56/71
Example (HL inD
rip Zone) The drip supplier specifies that for 200The drip supplier specifies that for 200--ftft
laterals, the losses in the drip lines willlaterals, the losses in the drip lines will
be 18 ft (Table 3A).be 18 ft (Table 3A).
-
8/9/2019 Drip Irrigation - Penn State University
57/71
-
8/9/2019 Drip Irrigation - Penn State University
58/71
Example (Size the Return Pipe) With a design flow rate of 6.4 gpm andWith a design flow rate of 6.4 gpm and
using PVCusing PVC--scheduleschedule--40 pipe, we will40 pipe, we will
need a 1.0need a 1.0--inch pipe to keep theinch pipe to keep thevelocity above 2.0 fps. (V = 2.30 fps).velocity above 2.0 fps. (V = 2.30 fps).
This 1.00This 1.00--in PVC pipe has a frictionin PVC pipe has a friction
factor, Ffactor, Fcc = 0.95 psi/100 ft or 2.19 ft/100= 0.95 psi/100 ft or 2.19 ft/100ft.ft.
-
8/9/2019 Drip Irrigation - Penn State University
59/71
Example (HL in Return Pipe) Before we can determine the HBefore we can determine the HLL in thisin this
pipe, we must determine the length ofpipe, we must determine the length of
the supply pipe [this is assumed to be athe supply pipe [this is assumed to be astraight pipe].straight pipe].
The length of pipe was given at 140The length of pipe was given at 140
ft.ft.
-
8/9/2019 Drip Irrigation - Penn State University
60/71
Example (HL in Return Pipe) The HThe HLL is calculated from:is calculated from:
HHLL = F= FccLL
HHLL = 2.19 ft/100 ft(140ft) = 3.07 ft.= 2.19 ft/100 ft(140ft) = 3.07 ft.
-
8/9/2019 Drip Irrigation - Penn State University
61/71
Example (HL Summary) The Head Loss (or Friction) for theseThe Head Loss (or Friction) for these
four sections of our system is:four sections of our system is:
HHLL Dose Tank to the HU = 1.02 ft.Dose Tank to the HU = 1.02 ft.
HHLL Supply Pipe = 1.62 ft.Supply Pipe = 1.62 ft.
HHLL Drip Lines = 18 ft.Drip Lines = 18 ft.
HHLL Return Pipe = 3.07 ftReturn Pipe = 3.07 ft
Total HTotal HLL = 23.7 ft.= 23.7 ft.
-
8/9/2019 Drip Irrigation - Penn State University
62/71
-
8/9/2019 Drip Irrigation - Penn State University
63/71
Example (Pressure Requirements) Without having worked with this system, IWithout having worked with this system, I
would assume the following:would assume the following:
The pressure needed to run the HU shouldThe pressure needed to run the HU shouldbe 10 to 20 psi (23 to 46 ft).be 10 to 20 psi (23 to 46 ft).
The pressure needed to make the emittersThe pressure needed to make the emittersfunction properly is generally about 10 psifunction properly is generally about 10 psi(23 ft).(23 ft).
The total pressure requirement = 46 + 23 =The total pressure requirement = 46 + 23 =69 ft.69 ft.
-
8/9/2019 Drip Irrigation - Penn State University
64/71
Example (ElevationD
ifference) Elevation differences include:Elevation differences include:
Rise from enabler float in dose tank toRise from enabler float in dose tank to
Hydraulic Unit (+ 7 ft).Hydraulic Unit (+ 7 ft).
Rise from the Hydraulic Unit to theRise from the Hydraulic Unit to the
drip Zones (+20 ft).drip Zones (+20 ft).
Total elevation rise = 7 + 20 = 27 ft.Total elevation rise = 7 + 20 = 27 ft.
-
8/9/2019 Drip Irrigation - Penn State University
65/71
Bernoulli Summary (D
osing) The total energy needed to run thisThe total energy needed to run this
system is:system is:
HHLL = 23.7 ft.= 23.7 ft.
Pressure = 69 ft.Pressure = 69 ft.
Elevation rise = 27 ft.Elevation rise = 27 ft.
Total during dosing = 120 ft.Total during dosing = 120 ft.
Flow rate = 10.7 gpm.Flow rate = 10.7 gpm.
-
8/9/2019 Drip Irrigation - Penn State University
66/71
Bernoulli Summary (Back Flushing)
The total energy needed to run thisThe total energy needed to run this
system is:system is:
HHLL = 115 + 1.02 = 116 ft.= 115 + 1.02 = 116 ft.
Pressure = 0 ft.Pressure = 0 ft.
Elevation rise = 7 ft.Elevation rise = 7 ft.
Total during dosing = 123 ft.Total during dosing = 123 ft.
Flow rate = 15 gpm.Flow rate = 15 gpm.
-
8/9/2019 Drip Irrigation - Penn State University
67/71
Example (Pump Requirement) ForDosingForDosing
HHTT = 120 ft= 120 ft
Q = 10.7 gpmQ = 10.7 gpm
For Back FlushingFor Back Flushing
HHTT = 123 ft.= 123 ft.
Q = 15 gpm.Q = 15 gpm.
Pump DesignPump Design
HHTT = 123 ft.= 123 ft. Q = 15 gpmQ = 15 gpm..
-
8/9/2019 Drip Irrigation - Penn State University
68/71
Example (Time/D
ose)Average daily flow = 200 gpdAverage daily flow = 200 gpd
Each zone accounts for 50% of flow.Each zone accounts for 50% of flow.
Zone 1 = 100 gpdZone 1 = 100 gpdZone 2 = 100 gpdZone 2 = 100 gpd
At 4 doses /zone/day; each dose mustAt 4 doses /zone/day; each dose must
apply 25 gal.apply 25 gal. Time/dose = 25 gal/dose/4.3 gpmTime/dose = 25 gal/dose/4.3 gpm
= 5.8 min= 5.8 min
-
8/9/2019 Drip Irrigation - Penn State University
69/71
-
8/9/2019 Drip Irrigation - Penn State University
70/71
Example (Time/D
ose) Under condition of Maximum daily flowUnder condition of Maximum daily flow
(400 gpd)(400 gpd)
We apply 200 gal/zone/dayWe apply 200 gal/zone/day
At 4.3 gpm (25 gal/dose).At 4.3 gpm (25 gal/dose).
200/25 = 8 doses/day.200/25 = 8 doses/day.
-
8/9/2019 Drip Irrigation - Penn State University
71/71