driscoplex® 6500 medium density gas distribution pipingdeaconind.com/customer/deinsu/specpages/6500...

7
PerformancePipe.com DRISCOPLEX ® 6500 MDPE PIPE and FITTINGS DATA SHEET Bulletin: PP107 / March 2010 © 2009 Chevron Phillips Chemical Company LP Performance Pipe, a division of Chevron Phillips Chemical Company LP | 5085 W. Park Blvd | Suite 500 | Plano, TX 75093 | Phone: 800-527-0662 | Fax: 972-599-7348 This data sheet provides typical properties for Performance Pipe DriscoPlex® pipe and fittings. Before using this product, the user is advised and cautioned to make their own determination and assessment of the safety and suitability of the product for the specific use in question and is further advised against relying on the information contained herein as it may relate to any specific use or application. It is the ultimate responsibility of the user to ensure that the product is suited and the information is applicable to the user’s specific application. Chevron Phillips Chemical Company LP does not make, and expressly disclaims, all warranties, including warranties of merchantability or fitness for a particular purpose, regardless of whether oral or written, express or implied, allegedly arising from any usage of any trade or from any course of dealing in connection with the use of information contained herein or the product itself. The user expressly assumes all risk and liability, whether based in contract, tort or otherwise, in connection with the use of the information contained herein or the product itself. Further, information contained herein is given without reference to any intellectual property issues, as well as federal, state or local laws which may be encountered in the use thereof. Such questions should be investigated by the user. The data sheet may change periodically. Visit www.PerformancePipe.com for the most current data sheet. Page 1 of 1 DriscoPlex ® 6500 Pipe and Fittings meet or exceed: DriscoPlex® 6500 Yellow MDPE Pipe and Fittings for ASTM D2513, D2683, D3261 CAN/CSA-B137.4 UPC ASTM D3350, cell classification PE234373E and PE234375E PPI TR-4 designations PE2708 (PE2406) and PE80 PPI TN-30 Natural Gas Distribution, LPG and Propane Gas Distribution, Yard Gas Iron Pipe Size OD (IPS) ½” to 24”, Copper Tube Size OD (CTS) ½” to 1 ¼” Coils available up through 6” Outdoor Storage up to Three (3) Years per ASTM D2513 NOMINAL PIPE PROPERTIES (1) UNIT TEST METHOD VALUE Density gms / cm 3 ASTM D1505 0.939 (yellow) Melt Index (MI) Condition 190°C / 2.16kg gms / 10 min ASTM D1238 0.18 Hydrostatic Design Basis 73°F (23°C) psi ASTM D2837 1250 Hydrostatic Design Basis 140°F (60°C) psi ASTM D2837 1000 Minimum Required Strength MPa (psi) ISO 9080 8.0 (116) Rapid Crack Propagation (Pc) 0°C (32°F) (3) Bar (psi) ISO 13478 8.5 (123) Color; UV Stabilizer [E] -- ASTM D3350 Yellow; UV stabilized Pipe Test Category -- ASTM D2513 CEE NOMINAL MATERIAL PROPERTIES (1) (2) UNIT TEST METHOD VALUE Flexural Modulus at 2% secant psi ASTM D790 >90,000 Tensile Strength at Yield psi ASTM D638 Type IV 2,800 Elongation at Break 2 in / min., Type IV bar % ASTM D638 >800 Hardness Shore D ASTM D2240 63 PENT hrs ASTM F1473 >2,000 Vicat Softening Temperature °F ASTM D1525 227 Brittleness Temperature °F ASTM D746 < -103 1. This is not a product specification and does not guarantee or establish specific minimum or maximum values or manufacturing tolerances for material or piping products to be supplied. 2. Values obtained from tests of specimens taken from piping product may vary from these typical values. 3. Determination made on 8" DR-11 pipes for Full Scale test. Pc calculated in accordance with ISO 13478.

Upload: others

Post on 17-Jan-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Driscoplex® 6500 Medium Density Gas Distribution Pipingdeaconind.com/Customer/DEINSU/specpages/6500 poly pipe.pdfPPI TR-4 designations PE2708 (PE2406) and PE80 PPI TN-30 Propane Gas

PerformancePipe.com

DRISCOPLEX® 6500 MDPE PIPE and FITTINGS DATA SHEET

Bulletin: PP107 / March 2010 © 2009 Chevron Phillips Chemical Company LP

Performance Pipe, a division of Chevron Phillips Chemical Company LP | 5085 W. Park Blvd | Suite 500 | Plano, TX 75093 | Phone: 800-527-0662 | Fax: 972-599-7348

This data sheet provides typical properties for Performance Pipe DriscoPlex® pipe and fittings. Before using this product, the user is advised and cautioned to make their own determination and assessment of the safety and suitability of the product for the specific use in question and is further advised against relying on the information contained herein as it may relate to any specific use or application. It is the ultimate responsibility of the user to ensure that the product is suited and the information is applicable to the user’s specific application. Chevron Phillips Chemical Company LP does not make, and expressly disclaims, all warranties, including warranties of merchantability or fitness for a particular purpose, regardless of whether oral or written, express or implied, allegedly arising from any usage of any trade or from any course of dealing in connection with the use of information contained herein or the product itself. The user expressly assumes all risk and liability, whether based in contract, tort or otherwise, in connection with the use of the information contained herein or the product itself. Further, information contained herein is given without reference to any intellectual property issues, as well as federal, state or local laws which may be encountered in the use thereof. Such questions should be investigated by the user. The data sheet may change periodically. Visit www.PerformancePipe.com for the most current data sheet.

Page 1 of 1

DriscoPlex® 6500 Pipe and Fittings meet or exceed: DriscoPlex® 6500 Yellow MDPE Pipe and Fittings for

ASTM D2513, D2683, D3261

CAN/CSA-B137.4

UPC

ASTM D3350, cell classification PE234373E and PE234375E

PPI TR-4 designations PE2708 (PE2406) and PE80

PPI TN-30

Natural Gas Distribution, LPG and

Propane Gas Distribution, Yard Gas

Iron Pipe Size OD (IPS) ½” to 24”, Copper Tube Size OD (CTS) ½” to 1 ¼”

Coils available up through 6”

Outdoor Storage up to Three (3) Years per ASTM D2513

NOMINAL PIPE PROPERTIES (1)

UNIT TEST METHOD VALUE

Density gms / cm3 ASTM D1505 0.939 (yellow)

Melt Index (MI) Condition 190°C / 2.16kg gms / 10 min ASTM D1238 0.18

Hydrostatic Design Basis 73°F (23°C) psi ASTM D2837 1250

Hydrostatic Design Basis 140°F (60°C) psi ASTM D2837 1000

Minimum Required Strength MPa (psi) ISO 9080 8.0 (116)

Rapid Crack Propagation (Pc) 0°C (32°F) (3)

Bar (psi) ISO 13478 8.5 (123)

Color; UV Stabilizer [E] -- ASTM D3350 Yellow; UV stabilized

Pipe Test Category -- ASTM D2513 CEE

NOMINAL MATERIAL PROPERTIES (1) (2)

UNIT TEST METHOD VALUE

Flexural Modulus at 2% secant psi ASTM D790 >90,000

Tensile Strength at Yield psi ASTM D638 Type IV 2,800

Elongation at Break 2 in / min., Type IV bar % ASTM D638 >800

Hardness Shore D ASTM D2240 63

PENT hrs ASTM F1473 >2,000

Vicat Softening Temperature °F ASTM D1525 227

Brittleness Temperature °F ASTM D746 < -103

1. This is not a product specification and does not guarantee or establish specific minimum or

maximum values or manufacturing tolerances for material or piping products to be supplied. 2. Values obtained from tests of specimens taken from piping product may vary from these typical

values. 3. Determination made on 8" DR-11 pipes for Full Scale test. Pc calculated in accordance with ISO

13478.

Page 2: Driscoplex® 6500 Medium Density Gas Distribution Pipingdeaconind.com/Customer/DEINSU/specpages/6500 poly pipe.pdfPPI TR-4 designations PE2708 (PE2406) and PE80 PPI TN-30 Propane Gas

CTS = COPPER TUBE SIZE

IPS = IRON PIPE SIZE

Please visit www.performancepipe.com for the most up-to-date information

DriscoPlex® 6500 Series PE2708 (PE2406)

Standard Size and Dimension Sheet

Bulletin: PP 156 –2708 | November 2012 ©2012 Chevron Phillips Chemical Company LP

Performance Pipe , a division of 5085 W. Park Blvd., Suite 500 Phone: 800-527-0662 Chevron Phillips Chemical Company LP Plano, TX 75093 Fax: 972-599-7329

Nominal Packing

Dimensions

ID / OD / Width

1/2" 7 0.625 0.09 100 6.5 1,000’ 30"/44"/6" 12 12,000’ 26 312,000’

1" 11.5 1.125 0.099 76 14 500' 30"/42"/11" 8 4,000' 26 104,000'

Pallet/ Bundle Footage

Number Pallet /

Bundles Per Truck

48 ft. Truck

Weight (lbs) per

100 ft.

Minimum Wall

(Inches)

Outside Diameter (Inches)

Dimension Ratio

MAOP (psig per CFR Part

192 @100 F or less)

Coil/Joint (feet)

Number Coils /

Joints Per Pallet or Bundle

Nominal Size

(Inches)

Nominal Packing

Dimensions

ID / OD / Width

3/4" 11 1.05 0.095 80 12 500' 30"/44"/10" 7 3,500’ 26 91,000'

1" 11 1.315 0.12 80 19 500' 30"/44"/12" 6 3,000' 26 78,000'

1 1/4" 10 1.66 0.166 89 33 500' 48"/72"/7-1/2" 12 6,000' 7 42,000'

1 1/2" 11 1.9 0.173 80 40 500' 48"/75"/8-1/2" 8 4,000' 7 28,000'

2" 11 2.375 0.216 80 63 500' 52"/78"/13" 7 3,500' 7 24,500'

11 3.5 0.318 80 136 500' 70”/96”/23-3/4" 4 2,000’ 6 12,000’

40’ soft bundles 50 2,000’ 14 28,000’

500’ 70”/96”/23-3/4" 4 2,000’ 6 12,000’

11 4.5 0.409 80 225 500' 70”/93"/41” 2 1,000' 6 6,000'

40' soft bundles 29 14 16,240’

600’ 70”/93"/49-1/2” upright 12 7,200’

1,000’ 84”/116”/49” upright 8 coils 8,000’

40' soft bundles 13 14 7,280'

500’ 84”/120”/50” upright 8 coils 4,000’

40' soft bundles 13 14 7,280'

500’ 84”/120”/50” upright 8 coils 4,000’

11.5 0.75 76 798

13.5 0.639 64 690

12" 13.5 12.75 0.944 64 1507 40' bulk packs 8

joints/layer 320' 6 1,920'

Pressure Rating is based on an operating temperature of 73°F per 49 CFR 192. Pipe weights are calculated in accordance with PPI TR-7. Nominal OD and Minimum wall plus 6% is used in estimating fluid flow. Actual ID will vary. When designing components to fit the pipe ID, refer to pipe dimensions and tolerances in the applicable pipe manufacturing specification.

520’

Weight (lbs) per

100 ft.

1,160’

10 3,600' 8" 8.625 40' soft bundles 9 360’

3"

4"

471

0.49113.5 64 407

6"

0.576

6.625

11.5 76

131

0.3914.511.5 76 217

0.3043.511.5 76

Coil/Joint (feet)

Number Coils /

Joints Per Pallet or Bundle

Pallet/ Bundle Footage

Number Pallet /

Bundles Per Truck

48 ft. Truck

Nominal Size

(Inches)

Minimum Wall

(Inches)

Outside Diameter (Inches)

Dimension Ratio

MAOP (psig per CFR Part

192 @100 F or less)

Page 3: Driscoplex® 6500 Medium Density Gas Distribution Pipingdeaconind.com/Customer/DEINSU/specpages/6500 poly pipe.pdfPPI TR-4 designations PE2708 (PE2406) and PE80 PPI TN-30 Propane Gas

Packaging Information IPS Gas Soft Sided Bundles

Performance Pipe, a division of 5085 W Park Blvd., Suite 500 Phone: 800-527-0662 Chevron Phillips Chemical Company LP Plano, TX 75093 Fax: 972-599-7348

Revised: 02/27/2013 Page 1 of 5 (CR Packaging Manual B.1.a.4) Information contained herein is being supplied for estimating purposes only, and is subject to change without notice.

PERFORMANCE PIPE IPS PRODUCTS SOFT-SIDED BUNDLES

(20’,40’ & 50’ Joints)

Size (Note 1)

Bundle Style

Pipe OD

Joints Per

Bundle

Bundles Per Truck 20’/40’/50’

Joints Per Truck

20’/40’/50’ DR

Feet Per Truck

20’ Joints

Feet Per Truck

40’ Joints

Feet Per Truck

50’ Joints

3” Soft 3.500” 50

20 / 10 / NA 1,000 / 500 / NA 7 20,000’ 20,000’ N/A

26 / 13 / NA 1,300 / 650 / NA 9 26,000’ 26,000’ N/A 28 / 14 / NA 1,400 / 700 / NA 11-19 28,000’ 28,000’ N/A

4” Soft 4.500” 29

22 / 11 / 9 638 / 319 / 261 7 12,760’ 12,760 13,050’

28 / 14 / 11 812 / 406 / 319 9 16,240’ 16,240’ 15,950’

28 / 14 / 13 812 / 406 / 377 11 16,240’ 16,240’ 18,850’

28 / 14 / 14 812 / 406 / 406 13.5 -19 16,240’ 16,240’ 20,300’

6” Soft 6.625” 13

22 / 11 / 9 286 / 143 / 117 7 5,720’ 5,720’ 5,850’

28 / 14 / 11 364 / 182 / 143 9 7,280’ 7,280’ 7,150'

28 / 14 / 14 364/ 182 / 182 11 - 19 7,280’ 7,280’ 9,100’

8” Soft 8.625” 9 20 / 10 / 10 180 / 90 / 90 11-19 3,600’ 3,600’ 4,500’ Note 1: GAS DISTRIBUTION When travelling in states with a 13’ 6” maximum height restriction shipping 13 or 14 bundles of 3” or 6”

may exceed the height restriction unless the trailer height is 58”or below (depending on the thickness of the bottom board utilized).

Page 4: Driscoplex® 6500 Medium Density Gas Distribution Pipingdeaconind.com/Customer/DEINSU/specpages/6500 poly pipe.pdfPPI TR-4 designations PE2708 (PE2406) and PE80 PPI TN-30 Propane Gas

Packaging Information IPS Gas Soft Sided Bundles

Performance Pipe, a division of 5085 W Park Blvd., Suite 500 Phone: 800-527-0662 Chevron Phillips Chemical Company LP Plano, TX 75093 Fax: 972-599-7348

Revised: 02/27/2013 Page 2 of 5 (CR Packaging Manual B.1.a.4) Information contained herein is being supplied for estimating purposes only, and is subject to change without notice.

Soft – Sided Style: For encasing all straight lengths between 3.500” OD and 8.625” OD.

(1) Lumber Sizes and Placement:

(a) Will be constructed using 3” x 4” bottom boards for GAS DISTRIBUTION (SERIES 6500-8100-8300).( 3” x 4”

boards actually have a thickness of approximately 2.5”, not to be less than 2”) Hardwood or softwood is acceptable. Grooved boards are preferable, but not mandatory as the banding will create a notch in some soft woods securing the banding in place.

(b) The bottom board length requirement is that the bottom board must go past the center point of the outer joints but not extend past the outer edge of the outer joint.

(c) Bottom boards are spaced at three (3) equidistant locations for twenty-foot (20’) joints. (d) Bottom boards are spaced at six (6) equidistant locations for forty-foot (40’) joints. (e) Bottom boards are spaced at seven (7) or eight (8) equidistant locations for fifty-foot (50’) joints

depending on bundling cart and plant.

(2) Top Boards:

(a) Top boards may be used to increase the stability of 3” to 8” soft bundles at manufacturer’s discretion or at the customer’s request.

(b) Top boards are placed on each end of the bundle, in line with the end bottom board. (Optional middle top boards are acceptable)

(c) Top boards may be constructed of 2” X 6” boards. The thickness of the top board should not exceed the thickness of the bottom board. Hardwood or softwood is acceptable.

(d) The top board length requirement is that the top board must go past the center point of the outer joints but not extend past the outer edge of the outer joint.

IPS Pipe Size Target Board Length

3” 42” (+0.75”, -0.00”) 4” 42” (+0.75”, -0.00”) 6” 42” (+0.75”, -0.00”) 8” 42” (+0.75”, -0.00”)

IPS Pipe Size Target Board Length 3” 42” (+0.75”, -0.00”) 4” 42” (+0.75”, -0.00”) 6” 42” (+0.75”, -0.00”) 8” 42” (+0.75”, -0.00”)

Page 5: Driscoplex® 6500 Medium Density Gas Distribution Pipingdeaconind.com/Customer/DEINSU/specpages/6500 poly pipe.pdfPPI TR-4 designations PE2708 (PE2406) and PE80 PPI TN-30 Propane Gas

Packaging Information IPS Gas Soft Sided Bundles

Performance Pipe, a division of 5085 W Park Blvd., Suite 500 Phone: 800-527-0662 Chevron Phillips Chemical Company LP Plano, TX 75093 Fax: 972-599-7348

Revised: 02/27/2013 Page 3 of 5 (CR Packaging Manual B.1.a.4) Information contained herein is being supplied for estimating purposes only, and is subject to change without notice.

(3) Banding: It is important that each band on a soft-side bundle be tightened to the same tension. Air regulated or battery operated banding equipment is acceptable. Use at least one ¾” X .050 or 5/8” X.035 polyester banding per bottom board. If using 5/8” X .035 polyester place one band around pipe between boards. At the plant’s discretion one band may please placed around the pipe on each end of the pack to help secure the caps/plugs and to stabilize the pack.

(4) Storage:

Soft-side bundles must be stacked plumb to prevent leaning. Special care must be taken when staging bundles in storage. Packs may be stacked in the plant yard on lumber to prevent the bottom of the pipe from coming in contact with the ground.

(5) Transport:

Performance Pipe Transport Strapping Policy (A.10 Pckg EXH2-Strapping Table) establishes minimum requirements regarding the number of trucker straps used by all transportation providers to secure bundles. The policy also contains conditions regarding the tightening of straps after a carrier leaves a Performance Pipe facility.

(6) Tarping:

All 6500-8100-8300 series bundles may be smoked tarped at least 8’ back on top and 8’ in front and on sides

or full tarped depending on customer request.

(7) End Caps: Place ventilated end caps (or plugs) on all 6500-8100-8300 series products.

Page 6: Driscoplex® 6500 Medium Density Gas Distribution Pipingdeaconind.com/Customer/DEINSU/specpages/6500 poly pipe.pdfPPI TR-4 designations PE2708 (PE2406) and PE80 PPI TN-30 Propane Gas

Packaging Information IPS Gas Soft Sided Bundles

Performance Pipe, a division of 5085 W Park Blvd., Suite 500 Phone: 800-527-0662 Chevron Phillips Chemical Company LP Plano, TX 75093 Fax: 972-599-7348

Revised: 02/27/2013 Page 4 of 5 (CR Packaging Manual B.1.a.4) Information contained herein is being supplied for estimating purposes only, and is subject to change without notice.

IPS – Soft Sided Bundles (Examples)

3” IPS 4” IPS 50 Joints Per Bundle 29 Joints Per Bundle

6” IPS 8” IPS 13 Joints Per Bundle 9 Joints Per Bundle GAS DISTRIBUTION ONLY

Page 7: Driscoplex® 6500 Medium Density Gas Distribution Pipingdeaconind.com/Customer/DEINSU/specpages/6500 poly pipe.pdfPPI TR-4 designations PE2708 (PE2406) and PE80 PPI TN-30 Propane Gas

Packaging Information IPS Gas Soft Sided Bundles

Performance Pipe, a division of 5085 W Park Blvd., Suite 500 Phone: 800-527-0662 Chevron Phillips Chemical Company LP Plano, TX 75093 Fax: 972-599-7348

Revised: 02/27/2013 Page 5 of 5 (CR Packaging Manual B.1.a.4) Information contained herein is being supplied for estimating purposes only, and is subject to change without notice.

IPS – Soft Sided Bundle Patterns

(20’, 40’ & 50’ Joints)

Size Pipe OD

Bundle Style

Bundle Height (Note 2)

BTM Board Length (Note 1)

Joints Per

Bundle

Bundles Per Truck

20’/40’/50’ Bundle Pattern

DR

Feet Per 20’

Bundle

Feet Per 40’

Bundle

Feet Per 50’

Bundle

3”

(Note 3)

3.500” Soft 15.093” 42” 50

20/10/NA

13/12/13/12

7 1,000’ 2,000’ N/A

26/13/NA 9 1,000’ 2,000’ N/A

28/14/NA 11-19 1,000’ 2,000’ N/A

4” 4.500” Soft 14.794” 42” 29

22/11/9

10/9/10

7 580’ 1,160’ 1,450’

28/14/11 9 580’ 1,160’ 1,450’

28/14/13 11 580’ 1,160’ 1,450’

28/14/14 13.5-19 580’ 1,160’ 1,450’

6”

(Note 3)

6.625” Soft 14.862” 42” 13

22/11/9

7/6

7 260’ 520’ 650’

28/14/11 9 260’ 520’ 650’

28/14/14 11-19 260’ 520’ 650’

8” 8.625”

Soft 18.594” 42” 9 20/10/10 5/4 11-19 180’ 360’ 450’ Note 1 : Figure is also top board length

Note 2 : Bundle height determined using 2 ½” thick boards.

Note 3 : When travelling in states with a 13’ 6” maximum height restriction shipping 13 or 14 bundles of 3” or 6” may

exceed the height restriction unless the trailer height is 58” or below (depending on the thickness of the bottom

board utilized).