dry and adiabatic cooling products - baltimore aircoil · counterflow axial fan dfcv cooler 220 -...

2
Principle of operation Configuration Air entry Capacity www.BaltimoreAircoil.eu Maximum entering fluid temperature Dry and adiabatic cooling products Operational safety (hygiene) Low sound Energy efficiency Easy maintenance Water saving Best G A counterflow axial fan induced draft DFCV-AD cooler 220 - 1620 kW 60°C C A A D B counterflow axial fan induced draft DCV-AD condenser 340 - 1030 kW / C A A D B counterflow axial fan induced draft SP cooler 340 - 1560 kW 60°C C A A D B counterflow axial fan induced draft DFCV cooler 220 - 1500 kW 60°C D D A A A counterflow axial fan induced draft 250 - 2000 kW 60°C A A B D E Tab v04 EN © 2017 Baltimore Aircoil International nv TVFC cooler

Upload: phungkhue

Post on 23-Apr-2018

217 views

Category:

Documents


1 download

TRANSCRIPT

Principle ofoperation

Configuration

Air entry

Capacity

www.BaltimoreAircoil.eu

Maximum entering fluid temperature

Dry and adiabatic cooling products

Operational safety (hygiene)

Low sound

Energy efficiency

Easy maintenance

Water saving

BestG A

counterflow

axial fan induced draft

DFCV-AD cooler

220 - 1620 kW

60°C

C

A

A

D

B

counterflow

axial fan induced draft

DCV-AD condenser

340 - 1030 kW

/

C

A

A

D

B

counterflow

axial fan induced draft

SP cooler

340 - 1560 kW

60°C

C

A

A

D

B

counterflow

axial fan induced draft

DFCV cooler

220 - 1500 kW

60°C

D

D

A

A

A

counterflow

axial fan induced draft

250 - 2000 kW

60°C

A

A

B

D

E

Tab v04 EN © 2017 Baltimore Aircoil International nv

TVFC cooler

Dry and adiabatic cooling productsDr

y an

d ad

iaba

tic co

olin

g pr

oduc

ts

Tab_DAC_ENv04

Dry or air cooled products Dryorair-cooledproductscoolliquidsorcondensategasesinclosedcircuitsviasensibleheattransferfromhigh-densityfinnedcoiltoairatambientdry bulb temperature.

Key benefits• Eliminates water treatment and reduces water usage • Eliminates plumes • Reduced maintenance • Eliminates Legionella risks

Why go for evaporative rather than dry cooling?• Whenyouneedafluidoutlettemperatureclosetothedesignambientdrybulbtemperature• To save on energy costs • If the cooling unit plan area is compact or restricted

Adiabatic products Adiabatic products are air-cooled coolers or condensers with adiabatic pre-coolers. Before the fan drawstheambientairthroughthefinnedcoil,theairispre-cooledadiabaticallywhentraversinganhumidification pad. This evaporates the water in the air, thus boosting the cooling capacity.

Key benefits• low process temperatures • saves more than 80% on annual water compared to cooling towers • up to 40% increased capacity compared to dry cooling (air temperatures approaching wet bulb

temperature) • reduced energy consumption • operational safety: no water recirculation, no stagnant water, no aerosol generation, no water carry-over