drywall ceiling with axiom drywall cloud … · armstrong drywall grid system - cross tee armstrong...

3
8' 8" KAM-12 KAM-12 DW90C DRYWALL CROSS TEE DRYWALL MAIN BEAM 5 8 " GYPSUM BOARD HANGER WIRE TO STRUCTURE HANGER WIRE TO STRUCTURE HANGER WIRE TO STRUCTURE KAM-12 KAM-12 DW90C VARIES AXTBC AXIOM PERIMETER TRIM (2",4",6",8",10" or 12") #12 HANGER WIRE #12 HANGER WIRE ARMSTRONG DRYWALL GRID SYSTEM 5/8" GYPSUM BOARD DRYWALL CLIP ARMSTRONG DRYWALL GRID SYSTEM 5/8" GYPSUM BOARD AXIOM BOTTOM DRYWALL TRIM 10'R 10'R RC2 SPLICE 8" O.C. 5/8" GYPSUM BOARD 5/8" GYPSUM BOARD DRYWALL 4' CROSS TEE - XL894 (16" O.C.) ARMSTRONG DRYWALL GRID HD8906 MAIN BEAM NOTCHED AND SPLICED (8" O.C.) RC2 SPLICE (8" O.C.) #12 HANGER WIRE 4' O.C. OR AS REQUIRED BY CODE ARMSTRONG DRYWALL GRID MAIN BEAM HD8906 NOTCHED AND SPLICED (8" O.C.) DETAIL "A" DETAIL "B" DETAIL "C" DETAIL "A" DETAIL "B" DETAIL "C" #12 HANGER WIRE ARMSTRONG DRYWALL MAIN BEAM ARMSTRONG DRYWALL CROSS TEE HANGER WIRE DRYWALL SCREW INCANDESCENT FIXTURE OUTRIGGER ARMSTRONG DRYWALL CROSS TEE ARMSTRONG DRYWALL MAIN BEAM GYPSUM BOARD DRYWALL GRID SYSTEM ARMSTRONG EXPOSED TEE GRID SYSTEM - CROSS TEE ARMSTRONG EXPOSED TEE GRID SYSTEM - CROSS TEE H.I.D. FIXTURE BY OTHERS ARMSTRONG EXPOSED TEE GRID SYSTEM - CROSS TEE H.I.D. FIXTURE BY OTHERS DRYWALL GRID SYSTEM ARMSTRONG EXPOSED TEE GRID SYSTEM - CROSS TEE GYPSUM BOARD CONCRETE SLAB SCRAP TEE BRACE MID SPAN 2' O.C. 12' 6' MAX. 48" MAX. KAM-12 KAM-12 48" MAX CORNER BEAD ANGLE MOLDING DECK 16" O.C. Armstrong is not licensed to provide professional architecture or engineering design services. These drawings show typical conditions in which the Armstrong product depicted is installed. DATE: DRAWN BY: DWG. NO. PROJECT NAME: SCALE: CHK BY: DESC.: REV: DATE: ARMSTRONG CEILING SYSTEMS * ARMSTRONG WORLD INDUSTRIES, INC. * Lancaster, PA * Phone: 877-ARMSTRONG They are not a substitute for an architect's or engineer's plan and do not reflect the unique requirements of local building codes,laws,statutes,ordinances,rules and regulations (Legal Reqquirements) that may be applicable for a particular installation. Armstrong does not warrant, and assumes no liability for the accuracy or completeness of the drawings for a particular installation or their fitness for a particular purpose. The user is advised to consult with a duly licensed architect or engineer in the particular locale of the installation to assure compliance with all Legal Requirements. DRYWALL CEILING WITH AXIOM DRYWALL CLOUD DRYWALL GRID SYSTEMS MASTER SHEETS SHEET 4 11/05/13 DRA . . . . . HIGH HAT FIXTURE IN DRYWALL CEILING SHORTSPAN _ KAM VERTICAL SOFFIT SHORTSPAN VERTICAL SOFFIT HID FIXTURE IN DRYWALL CEILING DRYWALL SERPENTINED CLOUD HIGH HAT FIXTURE IN DRYWALL CEILING DRYWALL CLOUD WITH DRYWALL UPTURN

Upload: doankhuong

Post on 14-Sep-2018

272 views

Category:

Documents


1 download

TRANSCRIPT

8'

8"

KAM-12

KAM-12

DW90CDRYWALL CROSS TEEDRYWALL MAIN BEAM

58" GYPSUM BOARD

HANGER WIRETO STRUCTURE

HANGER WIRETO STRUCTURE

HANGER WIRETO STRUCTURE

KAM-12

KAM-12

DW90C

VARIES

AXTBC

AXIOM PERIMETER TRIM(2",4",6",8",10" or 12")

#12 HANGER WIRE

#12 HANGER WIREARMSTRONG DRYWALLGRID SYSTEM

5/8" GYPSUM BOARDDRYWALL CLIP

ARMSTRONG DRYWALLGRID SYSTEM

5/8" GYPSUM BOARD AXIOM BOTTOMDRYWALL TRIM

10'R

10'R

RC2 SPLICE 8" O.C.

5/8" GYPSUMBOARD5/8" GYPSUM

BOARD

DRYWALL 4'CROSS TEE -

XL894 (16" O.C.) ARMSTRONG DRYWALLGRID HD8906 MAIN BEAMNOTCHED AND SPLICED(8" O.C.)

RC2 SPLICE(8" O.C.)

#12 HANGER WIRE4' O.C. OR AS REQUIREDBY CODE

ARMSTRONG DRYWALLGRID MAIN BEAM HD8906NOTCHED AND SPLICED(8" O.C.)

DETAIL "A" DETAIL "B" DETAIL "C"

DETAIL "A"

DETAIL "B"

DETAIL "C"

#12 HANGER WIRE

ARMSTRONG DRYWALLMAIN BEAM

ARMSTRONG DRYWALLCROSS TEE

HANGER WIRE

DRYWALL SCREW

INCANDESCENTFIXTURE OUTRIGGER

ARMSTRONG DRYWALLCROSS TEE

ARMSTRONG DRYWALLMAIN BEAM

GYPSUM BOARD

DRYWALL GRID SYSTEM

ARMSTRONG EXPOSEDTEE GRID SYSTEM -

CROSS TEE

ARMSTRONG EXPOSEDTEE GRID SYSTEM -CROSS TEE

H.I.D. FIXTUREBY OTHERS

ARMSTRONG EXPOSEDTEE GRID SYSTEM -

CROSS TEE

H.I.D. FIXTUREBY OTHERS

DRYWALL GRID SYSTEM

ARMSTRONG EXPOSEDTEE GRID SYSTEM -CROSS TEE

GYPSUM BOARD

CONCRETE SLAB

SCRAP TEEBRACEMID SPAN

2' O.C.

12'

6' MAX.

48" MAX.

KAM-12

KAM-12

48" MAX

CORNER BEAD

ANGLE MOLDING

DECK

16" O.C.

Armstrong is not licensed to provide professional architecture or engineering design services.

These drawings show typical conditions in which the Armstrong product depicted is installed.

DATE:

DRAWN BY:

DWG. NO.

PROJECT NAME:

SCALE:

CHK BY:

DESC.:

REV:

DATE:

ARMSTRONG CEILING SYSTEMS * ARMSTRONG WORLD INDUSTRIES, INC. * Lancaster, PA * Phone: 877-ARMSTRONG

They are not a substitute for an architect's or engineer's plan and do not reflect the unique requirements of

local building codes,laws,statutes,ordinances,rules and regulations (Legal Reqquirements) that may be

applicable for a particular installation.

Armstrong does not warrant, and assumes no liability for the accuracy or completeness of

the drawings for a particular installation or their fitness for a particular purpose.

The user is advised to consult with a duly licensed architect or engineer in the particular locale of the

installation to assure compliance with all Legal Requirements.

DRYWALL CEILING WITH AXIOM DRYWALL CLOUD

DRYWALL GRID SYSTEMS

MASTER SHEETS

SHEET 4

11/05/13

DRA

. .

.

.

.

HIGH HAT FIXTURE IN DRYWALL CEILING

SHORTSPAN _ KAM VERTICAL SOFFIT

SHORTSPAN VERTICAL SOFFIT

HID FIXTURE IN DRYWALL CEILING

DRYWALL SERPENTINED CLOUD

HIGH HAT FIXTURE IN DRYWALL CEILING

DRYWALL CLOUD WITH DRYWALL UPTURN

LAM-12

KAM-12KAM-12

HANGER WIRE TO STRUCTURE

DW90C

QUICKSTIX 6 MAIN BEAM

5/8" GYPBOARD

5/8" GYPBOARD

WALL10'

6"

10'8"

STRONGBACK STRONGBACK

HANGEWR WIRETO STRUCTURE

KAM-12OR LAM-12

KAM-12OR LAM-12

QUIKSTIX TEE

QS612/QS812QUIKSTIX TEE @ 48" O.C.

XL8945P CROSS TEE16" O.C.

XL8945P CROSS TEE16" O.C.

LAM-12OR KAM-12

QS612/QS812QUIKSTIX TEE @48" O.C.

QUIKSTIX TEE48" O.C.

LAM-12

LAM-12

XL8945P CROSS TEE16" O.C.

XL8945P CROSS TEE16" O.C.

XL8945P CROSS TEE16" O.C.

XL8945P CROSS TEE16" O.C.

QS612/QS812QUIKSTIX TEE @48" O.C.

QS612/QS812QUIKSTIX TEE @ 48" O.C.

QS612/QS812QUIKSTIX TEE @ 48" O.C.

32"

24"

LAM-12OR KAM-12

LAM-12OR KAM-12

13'

R182.81DETAIL "A"

DETAIL "B"

DETAIL "B"

DETAIL "B"

#12 HANGER WIRE(7891), 4' O.C., OR ASREQUIRED BY CODE.

DETAIL "B"(TYP.)5/8" GYPSUM BOARD

ARMSTRONG DRYWALLGRID SYSTEM ITEM#8901 OR #8906 MAINBEAM @ 4'O.C.

EXISTING WALL

STD. WALL ANGLE (BENTTO PROPER ANGLE)

DETAIL "A"

ARMSTRONGDRYWALL GRIDCROSS TEE #8945@ 16" O.C.

DETAIL "A"GRID SYSTEM

ARMSTRONG DRYWALLBOARD5/8" GYPSUM

DETAIL "B"

AXBT

DETAIL "C"

5/8" GYPSUM BOARDGRID SYSTEMARMSTRONG DRYWALL

DETAIL "D"

8'-6"

SECTION "A-A"

ARMSTRONG DRYWALLGRID SYSTEM

DETAIL "A"

6"

DETAIL "B"

DETAIL "C"

SECTION "B-B"

#12 HANGER WIRE, 4' O.C.,OR AS REQUIRED BY CODE.

5/8" GYPSUM BOARD(BY OTHERS)

5/8" GYPSUM

MODIFIED AXHGC

BOARD

AXTBC

4"AXIOMCLASSIC TRIM

6"

LIGHT FIXTURE

8'-6"6" 6"

GRID SYSTEM CROSS TEEARMSTRONG DRYWALL

"B"

DETAIL "D"

12"

"A"VAULTED AREA

REFLECTED VIEW OF

"A"

"B"

ARMSTRONGDRYWALL

GRID CROSSTEES 16" O.C.

KAM-12

5/8" GYPSUM BOARD

6"

8'-558"

8'-558"

6"

ARMSTRONG DRYWALL GRID SYSTEM

MAIN BEAM

ARMSTRONG DRYWALLGRID SYSTEMMAIN BEAM

STEEL STUDATTACHED TOSTRUCTURE ABOVE

DRYWALL GRIDSYSTEM CROSSTEE

2 LAYERS OFGYPSUM BOARD

STEEL STUDATTACHED TOSTRUCTURE ABOVE

#12 HANGERWIRE

RC2

DRYWALL CROSS TEE

DRYWALL MAIN BEAM

GYPSUM BOARD

2'-6"R

ARMSTRONG DRYWALLGRID SYSTEM CROSS TEE

#8945P

ARMSTRONG DRYWALL GRIDSYSTEM MAIN BEAM NOTCHED

& SPLICED APROX. 4" O.C.

1/2" GYPSUM BOARD

RC2

ARMSTRONG DRYWALL GRIDSYSTEM MAIN BEAM

NOTCHED & SPLICED APROX.4" O.C.

ARMSTRONG DRYWALLGRID SYSTEM CROSS TEE

#8945P

GYPSUM BOARD

DRYWALLCROSS TEE

RC2

DRYWALLMAIN BEAM

XTACCHANNEL MOLDING

GYPSUM BOARDDRYWALL

MAIN BEAM

#12 HANGER WIREMAX. 4' O.C.

XTACCHANNEL MOLDING

GYPSUM BOARDDRYWALL

MAIN BEAM

Armstrong is not licensed to provide professional architecture or engineering design services.

These drawings show typical conditions in which the Armstrong product depicted is installed.

DATE:

DRAWN BY:

DWG. NO.

PROJECT NAME:

SCALE:

CHK BY:

DESC.:

REV:

DATE:

ARMSTRONG CEILING SYSTEMS * ARMSTRONG WORLD INDUSTRIES, INC. * Lancaster, PA * Phone: 877-ARMSTRONG

They are not a substitute for an architect's or engineer's plan and do not reflect the unique requirements of

local building codes,laws,statutes,ordinances,rules and regulations (Legal Reqquirements) that may be

applicable for a particular installation.

Armstrong does not warrant, and assumes no liability for the accuracy or completeness of

the drawings for a particular installation or their fitness for a particular purpose.

The user is advised to consult with a duly licensed architect or engineer in the particular locale of the

installation to assure compliance with all Legal Requirements.

DRYWALL GRID SYSTEMS

MASTER SHEETS

SHEET 5

11/05/13

DRA

. . .

.

.

.

DRYWALL BARREL AND LIGHT COVE

DRYWALL BARREL VAULT

DRYWALL REVERSE BARREL VAULT

TWO INTERSECTING BARREL VAULTS

QUIKSTIX BOX SOFFIT WITH STRONGBACK

QUIKSTIX SOFFIT WITH STRONGBACK

QUICKSTIX TEE

QUIKSTIX POCKET

DRYWALL BARREL VAULT WITH DRYWALL END CAP

ARMSTRONG DRYWALLGRID SYSTEM - CROSS TEE

ARMSTRONG DRYWALLGRID SYSTEM - MAIN BEAM

24" DIAMETER SHEETMETAL PLATE (BY OTHERS)

VARIES

VARIESDETAIL "D"DETAIL "C"

DETAIL "B"

DETAIL "A"

"1""1"

CUTCUT

A

A

SESTION "A-A"

5/8" GYP BOARD

MAIN BEAM5/8"

PLYWOOD

6'

1'-10 316"

4'-61516"

1'-218"

1'-218"

58" GYPSUM BOARD

RC2

DRYWALL CROSS TEE

DRYWALL MAIN BEAMHD8906F08

HANGER WIRESTO STRUCTURE

MODIFIED KAM-21025

Armstrong is not licensed to provide professional architecture or engineering design services.

These drawings show typical conditions in which the Armstrong product depicted is installed.

DATE:

DRAWN BY:

DWG. NO.

PROJECT NAME:

SCALE:

CHK BY:

DESC.:

REV:

DATE:

ARMSTRONG CEILING SYSTEMS * ARMSTRONG WORLD INDUSTRIES, INC. * Lancaster, PA * Phone: 877-ARMSTRONG

They are not a substitute for an architect's or engineer's plan and do not reflect the unique requirements of

local building codes,laws,statutes,ordinances,rules and regulations (Legal Reqquirements) that may be

applicable for a particular installation.

Armstrong does not warrant, and assumes no liability for the accuracy or completeness of

the drawings for a particular installation or their fitness for a particular purpose.

The user is advised to consult with a duly licensed architect or engineer in the particular locale of the

installation to assure compliance with all Legal Requirements.

DRYWALL GRID SYSTEMS

MASTER SHEETS

SHEET 6

11/05/13

DRA

. .

.

.

.

DRYWALL DOME(RCP)

DRYWALL DOME

REVERSE DRYWALL DOME

REVERSE DRYWALL DOME (ELLIPSE)

CURVED MAIN BEAM TEMPLATE

DRYWALL DOME(SECTION VIEW)