  • 8/2/2019 Ds VF Extension Module

    1/14

    QLogicVirtualFabricExtensionModuleforIBMBladeCenter 1

    QLogic Virtual Fabric Extension Module for IBM

    BladeCenterIBM BladeCenter at-a-glance guide

    TheQLogicVirtualFabricExtensionModuleisanotherexampleofhowIBMhasbeenattheforefrontofofferingnewtechnologytoclients.IBMwasamongthefirsttodeliverFibreChanneloverEthernetacrossSystemxandBladeCenterandthisnewmoduletakesthisastepfurtherbyofferingclientsI/Oconvergenceinsidethechassis.

    ClientsusingtheBNTVirtualFabric10GbSwitchModulefortheirLANtrafficcannowcombineitwiththismoduleandaConvergedNetworkAdaptersuchastheQLogic2-port10GbCNAtoconvergetheirLANandSANonasinglenetwork.TheQLogicVirtualFabricExtensionModuleofferssixportsof8GbFibreChannelconnectivity,withouttheneedforseparateFibreChannelexpansioncardsintheBladeCenterservers.

    Figure1.QLogicVirtualFabricExtensionModuleforIBMBladeCenter

    Did you know?Thissolutionnotonlyoffersasimplifiedfabricbutalsoofferssignificantsavingsoverseparate10Gb/8Gbinfrastructure.Inadditiontothecostandmanagementsavings,thissolutionprovidestheflexibilitytoupgradeexistingchassistoimplementI/Oconvergencewithoutreplacingexisting10Gbswitches.Additionally,thismodulecanoperateeitherinfull-fabricmodeortransparent(NPIV)modedependingonyourFCstorageinfrastructurerequirements.

  • 8/2/2019 Ds VF Extension Module

    2/14

    QLogicVirtualFabricExtensionModuleforIBMBladeCenter 2

    Part number informationTable1showsthepartnumbertoorderthismodule.

    Table1.PartnumberandfeaturecodefororderingDescription Part number Feature codeQLogicVirtualFabricExtensionModule 46M6172 4799

    Thepartnumberincludesthefollowingitems:

    OneQLogicVirtualFabricExtensionModuleforIBMBladeCenterSupportCDTheIBMImportantNoticesdocumentWarrantyinformation

    TheQLogicVirtualFabricExtensionModulecomeswithoutSFP+modules,andtheymustbeordered

    additionally.Table2liststhepartnumberthatissupported.

    Table2.SupportedSFP+fortheQLogicVirtualFabricExtensionModule

    Description Part number Feature codeIBM8GbSFP+SWOpticalTransceiver 44X1964 5075

    FeaturesTheQLogicVirtualFabricExtensionModuleforIBMBladeCenterhasthefollowingfeatures:

    StandardI/Omoduleformfactor

    SixexternalautosensingFibreChannelportsthatoperateat8Gbps,4Gbps,or2Gbps

    Externalportscanbeconfiguredasfullfabric(GL,G,F,FL,E)FibreChannelports,ortransparentfabric(TF)FibreChannelports

    Upto40Gbpsofinternalbandwidthtotheswitchmodule

    Twointernalfull-duplex100MbpsEthernetinterfacesformanagement

    Power-onself-testdiagnosticsandstatusreporting

    SupportforNon-DisruptiveCodeLoadActivation(NDCLA)

    RegisteredStateChangeNotification(RSCN)

    Supportforstandards-basedFC-SW2interoperability

    Supportfortransparentmode(NPIV)

    Errordetection

    Cyclicredundancycheck(CRC)8-byteand10-byteconversionParityLongframeandshortframeD_IDmismatchS_IDmismatch

  • 8/2/2019 Ds VF Extension Module

    3/14

    QLogicVirtualFabricExtensionModuleforIBMBladeCenter 3

    Framebundling

    Noframebundling(framesareintermixedfromdifferentsourceports)

    Softlockdown(TheI/Omodulewaitsforthesequencetobecompletedoragapintheframetraffictooccurbeforeitservicesrequestsfromadifferentport.)

    ConfigurableFabricAddressNotification(FAN)

    Supportforupto239FabricExtensionModulesdependingontheconfiguration

    8Gbswitchfabricaggregatebandwidth:224Gbpsatfullduplex

    Maximumframesize:2148bytes(2112bytepayload)

    Nonblockingarchitecturetopreventlatency

    SupportfortheCallHomefunction

    SupportforDomainNameService(DNS)

    SupportforInternetProtocol(IP)Version6

    SupportforInternetProtocolsecurity(IPsec)

    Supportforseparatetrapcommunitystringsforeachtrapaddress

    SupportforSimpleNetworkManagementProtocol(SNMP)Version3

    Supportforvitalproductdata(VPD)

    SupportforoptionalSFP+modules

    Thefollowingsoftwarefeaturecomeswiththeswitchmodule:

    QuickToolsWebinterface

    Theswitchsupportsthefollowingfabricmanagement(allmanagementconnectionsgothroughthemanagementmodule):

    WebinterfacethroughQuickTools

    Command-lineinterface(CLI)throughtheTelnetprogram

    SwitchSNMPagent,whichenablesanetworkmanagementworkstationtoreceiveconfigurationvalues,trafficinformation,andFCfailuredatathroughSNMPandtheEthernetinterface

  • 8/2/2019 Ds VF Extension Module

    4/14

    QLogicVirtualFabricExtensionModuleforIBMBladeCenter 4

    Supported BladeCenter chassis, switch modules, and expansion cardsTheQLogicVirtualFabricExtensionModuleissupportedintheBladeCenterchassislistedinTable3.

    Table3.IBMBladeCenterchassisthatsupporttheQLogicVirtualFabricExtensionModule

    I/O module Part numberQLogicVirtualFabricExtensionModule 46M6172 N N Y N N N N

    TheBladeCenterHchassishasthefollowingbays:

    FourstandardI/Obays(1,2,3,4);bays3and4canalsobeusedasbridgebaysTwodedicatedbridgebays(5and6)

    Fourhigh-speedbays(7,8,9,and10)

    TheQLogicVirtualFabricExtensionModuleisinstalledinbays3and5.Installingtwobridges,oneineachbay,providesredundancyandperformancebenefitsalthoughitissupportedtoinstalloneQLogicVirtualFabricExtensionModuleinbay5only.TheQLogicVirtualFabricExtensionModulerequiresoneortwoBNTVirtualFabric10GbSwitchModules,46C7191.

    Dependingontheconfigurationused(asdescribedinthenextsection),twoorfourofthe10externalportsoftheBNTswitchmodulearereroutedinternallytotheextensionmodule.

    Table4.I/OmodulessupportedwiththeQLogicVirtualFabricExtensionModule

    I/O module Partnumber10GbEthernetPass-ThruModule 46M6181 N N N N N N N N N N

    BNTVirtualFabric10GbSwitchModule 46C7191 N N N N N N Y* N Y* N

    CiscoNexus4001ISwitchModule 46M6071 N N N N N N N N N N

    *TheBNTVirtualFabric10GbSwitchModuleisrequiredforproperoperationoftheQLogicVirtualFabricExtensionModule

  • 8/2/2019 Ds VF Extension Module

    5/14

    QLogicVirtualFabricExtensionModuleforIBMBladeCenter 5

    Figure2showstheI/OtopologyinternaltotheBladeCenterHchassis.Bridgebays3and5bothhaveinternalconnectionstothehighspeedI/Obays7and9.

    Figure2.BladeCenterHinternalconnectionswiththeQLogicVirtualFabricExtensionModuleinstalled

    ThesupportedexpansioncardsthatconnecttotheBNTVirtualFabric10GbSwitchModulearelistedinTable5.

    Table5.ExpansioncardssupportedwiththeQLogicVirtualFabricExtensionModule

    Expansion card Partnumber SupportedQLogicEthernetand4GbFibreChannelCard(CFFh) 39Y9306 No

    2/4PortEthernetExpansionCard(CFFh) 44W4479 No

    QLogicEthernetand8GbFibreChannelCard(CFFh) 44X1940 No

    NetXen10GbEthernetExpansionCard(CFFh) 39Y9271 No

    Broadcom10Gb2-portEthernetExpansionCard(CFFh) 44W4466 No

    Broadcom10Gb4-portEthernetExpansionCard(CFFh) 44W4465 No

    Broadcom10GbGen22-portEthernetExpansionCard(CFFh) 46M6168 No

    Broadcom10GbGen24-portEthernetExpansionCard(CFFh) 46M6164 No

    QLogic2-port10GbConvergedNetworkAdapter(CFFh) 42C1830 Yes

    EmulexVirtualFabricAdapter(CFFh) 49Y4245 No

    Intel10Gb2-portEthernetExpansionCard(CFFh) 42C1810 No

  • 8/2/2019 Ds VF Extension Module

    6/14

    QLogicVirtualFabricExtensionModuleforIBMBladeCenter 6

    Supported configurationsAsdescribedintheprevioussection,thethreecomponentsinthisconfigurationare:

    QLogic2-port10GbConvergedNetworkAdapter(CFFh)

    BNTVirtualFabric10GbSwitchModuleQLogicVirtualFabricExtensionModule

    ThesecomponentsaresupportedtogetherintheIBMBladeCenterchassisinthreepossibleconfigurations:

    Configuration 1: Maximum redundancy and bandwidthTwoswitchmodulesinbays7and9ofthechassisTwoextensionmodulesinbays3and5OneQLogic2-port10GbConvergedNetworkAdapter(CFFh)ineachserver

    AsshowninFigure2,theswitchinbay7isconnectedtotheextensionmoduleinbay3,andtheswitchin

    bay9isconnectedtotheextensionmoduleinbay5.Thisconfigurationresultsin40Gbpslinksbetweentheswitchandconnectedextensionmodule.Fourexternalportsofeachswitchmodule(8total)aredisabled(ports1-4inbay7andports7-10inbay9)andthosecircuitsarereroutedtotheextensionmodules.Thisconfigurationisbestforredundancyandbandwidth.Totalavailableexternalports:12Ethernet,12FibreChannel.

    Note:Thisconfigurationprecludestheuseofthebay3andbay4forI/OmodulesforusewithaCIOvcard.YoushouldnotinstallaCIOvcardinanybladesinstalledinthischassis.

    WeshowthisconfigurationindetailinthePopularconfigurationssectionbelow.

    Configuration 2: Maximum flexibilityTwoswitchmodulesinbays7and9ofthechassis

    Oneextensionmoduleinbay5OneQLogic2-port10GbConvergedNetworkAdapter(CFFh)ineachserver

    Inthisconfiguration,boththeswitchinbay7andtheswitchinbay9areconnectedtotheextensionmoduleinbay5.SeeFigure2fortheconnections.Thisconfigurationresultsin20Gbpslinksbetweeneachswitchandtheextensionmodule.Twoexternalportsofeachswitchmodule(4total)aredisabled(ports1and2inbay7,andports9and10inbay9)andthosecircuitsarereroutedtotheextensionmodule.Althoughtheextensionmoduleisnolongerredundant,itstillofferstheadvantagesoftwopathsfromtheadaptertotheswitchandextensionmodule.Unlikeconfiguration1,thisconfigurationallowstheuseoftheCIOvslotinthebladeservers(forexample,forSASconnectivity)toconnecttoI/Omodulesinstalledinbays3and4ofthechassis.Totalavailableexternalports:16Ethernet,6FibreChannel.

    WeshowthisconfigurationindetailinthePopularconfigurationssectionbelow.

  • 8/2/2019 Ds VF Extension Module

    7/14

    QLogicVirtualFabricExtensionModuleforIBMBladeCenter 7

    Configuration 3: Entry levelOneswitchmoduleinbay7(orbay9)ofthechassisOneextensionmoduleinbay5(orbay3)OneQLogic2-port10GbConvergedNetworkAdapter(CFFh)ineachserver

    Inthisconfiguration,onlyoneportoftheConvergedNetworkAdapterisactiveandonepathisestablishedfromtheadaptertotheswitchandontotheextensionmodule.Thisconfigurationresultsina40Gbpslinkbetweentheswitchandextensionmodule.Fourexternalportsoftheswitchmodulearedisabled(ports1-4ifbay7isusedorports7-10ifbay9isused)andthosecircuitsarereroutedtotheextensionmodule.Thisconfigurationdoesnotofferanyredundancy,butdoesmaximizebandwidthtotheextensionmodule.Iftheextensionmoduleisinstalledinbay5,thenconfigurationallowstheuseoftheCIOvslotinthebladeserverstoconnecttoI/Omodulesinstalledinbays3and4ofthechassis.Totalavailableexternalports:6Ethernet,6FibreChannel

    Table6comparesthenumberofavailableexternalportsintheseconfigurations.

    Table6.Comparingthesupportedconfigurations

    Configuration Total Ethernet ports Total Fibre Channel ports1 12 12

    2 16 6

    3 6 6

  • 8/2/2019 Ds VF Extension Module

    8/14

    QLogicVirtualFabricExtensionModuleforIBMBladeCenter 8

    Popular configurationsThissectionshowshowyoucanusetheQLogicVirtualFabricExtensionModuleinconfigurations.

    Two QLogic Virtual Fabric Extension Modules and two BNT Virtual Fabric Switch ModulesAsshowninFigure3(seealsoFigure2),theswitchinbay7isconnectedtotheextensionmoduleinbay3,andtheswitchinbay9isconnectedtotheextensionmoduleinbay5.Thisconfigurationresultsin40Gbpslinksbetweentheswitchandconnectedextensionmodule.Fourexternalportsofeachswitchmodulearedisabled(ports1-4inbay7andports7-10inbay9)andthosecircuitsarereroutedtotheextensionmodules.

    Figure3.ConvergednetworkingsolutionwithtwoQLogicVirtualFabricExtensionModulesandtwoBNTVirtualFabric10GbSwitchModules

    ThecomponentsusedinthisconfigurationarelistedinTable7.

    Table7.ComponentsofconvergednetworkingsolutionwithtwoQLogicVirtualFabricExtensionModulesandtwoBNTVirtualFabric10GbSwitchModules

    Diagramreference Part number Description Quantity

    Varies IBMBladeCenterHS22orserverthatsupportstheQLogic2-port10GbConvergedNetworkAdapter(CFFh)

    1to14

    42C1830 QLogic2-port10GbConvergedNetworkAdapter(CFFh) 1perserver

    8852 IBMBladeCenterHchassis 1

    46C7191 BNTVirtualFabric10GbSwitchModule 2

    44W4408 IBM10GBase-SRSFP+Transceiver Upto12*

    46M6172 QLogicVirtualFabricExtensionModule 2

    44X1964 IBM8GbSFP+SWOpticalTransceiver Upto12

  • 8/2/2019 Ds VF Extension Module

    9/14

    QLogicVirtualFabricExtensionModuleforIBMBladeCenter 9

    *WhileBNTVirtualFabric10GbSwitchModulehastenexternal10Gbports,theconfigurationdescribedaboveallowsuseofonlyuptosixexternalportsoneachBNTswitchbecausefour10GbexternalportsareremappedtofourinternalconnectionstoeachQLogicVirtualFabricExpansionModule,asshownonFigure3.

    Note: YoucanuseoneBNTVirtualFabric10GbSwitchModuleandoneQLogicVirtualFabricExpansionModuleintheconfigurationdescribedabove.Inthiscase,BNTVirtualFabric10GbSwitchModuleisinstalledintoI/Obay7andoneQLogicVirtualFabricExpansionModuleisinstalledintoI/Obay3orBNTVirtualFabric10GbSwitchModuleisinstalledintoI/Obay9andoneQLogicVirtualFabricExpansionModuleisinstalledintoI/Obay5oftheBladeCenterHchassis.Uptosixexternal10GbEthernetportsanduptosixexternalFCportsareavailableinthisconfiguration.

  • 8/2/2019 Ds VF Extension Module

    10/14

    QLogicVirtualFabricExtensionModuleforIBMBladeCenter 10

    One QLogic Virtual Fabric Extension Module and two BNT Virtual Fabric Switch ModulesInthisconfiguration,twoswitchesareinstalledinbay7andbay9andbothareconnectedtotheextensionmoduleinbay5.SeeFigure2andFigure3fortheconnections.Thisconfigurationresultsin20Gbpslinksbetweeneachswitchandtheextensionmodule.Twoexternalportsofeachswitchmodulearedisabled(ports1and2inbay7,andports9and10inbay9)andthosecircuitsarereroutedtotheextensionmodule.ThecomponentsusedinthisconfigurationarelistedinTable8.

    Figure4.ConvergednetworkingsolutionwithoneQLogicVirtualFabricExtensionModuleandtwoBNTVirtualFabric10GbSwitchModules

    Table8.ComponentsofconvergednetworkingsolutionwithoneQLogicVirtualFabricExtensionModuleandtwoBNTVirtualFabric10GbSwitchModules

    Diagramreference Part number Description Quantity

    Varies IBMBladeCenterHS22orserverthatsupportstheQLogic2-port10GbConvergedNetworkAdapter(CFFh) 1to14

    42C1830 QLogic2-port10GbConvergedNetworkAdapter(CFFh) 1perserver

    8852 IBMBladeCenterHchassis 1

    46C7191 BNTVirtualFabric10GbSwitchModulesinbays7and9 2

    44W4408 IBM10GBase-SRSFP+Transceiver Upto16*

    46M6172 QLogicVirtualFabricExtensionModuleinbay5 1

    44X1964 IBM8GbSFP+SWOpticalTransceiver Upto6

    *WhileBNTVirtualFabric10GbSwitchModulehastenexternal10Gbports,theconfigurationdescribedaboveallowsuseofonlyuptoeightexternalportsoneachBNTswitchbecausetwo10GbexternalportsoneachswitchareremappedtotwointernalconnectionstooneQLogicVirtualFabricExtensionModuleasshownonFigure4.

    Note: QLogicVirtualFabricExtensionModulemustbeinstalledinI/Obay5oftheBladeCenterHchassis.

  • 8/2/2019 Ds VF Extension Module

    11/14

    QLogicVirtualFabricExtensionModuleforIBMBladeCenter 11

    Connectors and LEDsFigure5showsthefrontpaneloftheQLogicVirtualFabricExtensionModule.ThesixexternalFibreChannelportssupporttheSFP+opticaltransceivermoduleslistedinTable2.

    Figure5.FrontpaneloftheQLogicVirtualFabricExtensionModule

    Table9liststheLEDsonthefrontpanelandtheirmeanings.

    Table9.LEDsonthefrontpanel

    LED name LED descriptionOK ThisgreenLEDisatthetopleftoftheI/Omoduleonthefrontpanelandindicatesthat

    themoduleisworkingproperly.

    !(I/Omodulefault) ThisamberLEDisatthetoprightoftheI/Omoduleonthefrontpanel.ThisLEDindicatesthattheI/Omodulehasafault.IftheI/OmodulefailsthePOST,thisfaultLEDislit.

    Externalportlogged-in(LOG)

    Therearesixgreenexternalportlogged-in(LOG)LEDs.WhenoneoftheseLEDsislit,itindicatesthatthereisaconnection(orlink)toadeviceonthatport.

    Externalportactivity(TX/RX)

    TherearesixgreenexternalportactivityLEDs.WhenoneoftheseLEDsflashes,itindicatesthatdataisbeingreceivedortransmitted(thatis,activityisoccurring)onthatport.Theflashfrequencyisproportionaltotheamountoftrafficonthatport.

    Externalportfault(!) Therearesixamberexternalportfault(!)LEDs.WhenanexternalportfaultLEDislit,itindicatesthattheexternalporthasfailedtheinternal,external,oronlineportdiagnosticstests.

  • 8/2/2019 Ds VF Extension Module

    12/14

    QLogicVirtualFabricExtensionModuleforIBMBladeCenter 12

    Operating environmentTheenvironmentmustmeetthefollowingtemperatureandaltituderequirements:

    Operating:10-52C(50-125F)atanaltitudeof0to914m(0to3,000ft)

    10-49C(50-20F)atanaltitudeof0to3,000m(0to10,000ft)

    Non-operating:40-65C(-40-149F)atanaltitudeof0to12,000m(0to39,370ft)

    Theenvironmenthasthefollowinghumiditylevelrequirements:

    Operating:8%to80%,noncondensingNon-operating:5%to80%,noncondensing

    Related publicationsFormoreinformation,seethefollowingdocuments:

    QLogicVirtualFabricExtensionModuleInstallationandUser'sGuide

    http://www.ibm.com/support/docview.wss?uid=psg1MIGR-5083051

    QLogichomepageforproductmanualsandfirmwareupdateshttp://driverdownloads.qlogic.com/QLogicDriverDownloads_UI/Product_detail_new.aspx?oemid=324

    IBMU.S.AnnouncementLetterhttp://ibm.com/common/ssi/cgi-bin/ssialias?infotype=dd&subtype=ca&&htmlfid=897/ENUS109-683

    IBMBladeCenterInteroperabilityGuidehttp://www.ibm.com/support/docview.wss?uid=psg1MIGR-5073016

    IBMRedbookspublicationIBMBladeCenterProductsandTechnology,SG24-7523http://www.redbooks.ibm.com/abstracts/sg247523.html

  • 8/2/2019 Ds VF Extension Module

    13/14

    QLogicVirtualFabricExtensionModuleforIBMBladeCenter 13

    Notices

    This information was developed for products and services offered in the U.S.A.

    IBM may not offer the products, services, or features discussed in this document in other countries. Consult your local

    IBM representative for information on the products and services currently available in your area. Any reference to anIBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may

    be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property

    right may be used instead. However, it is the user's responsibility to evaluate and verify the operation of any non-IBM

    product, program, or service. IBM may have patents or pending patent applications covering subject matter described

    in this document. The furnishing of this document does not give you any license to these patents. You can send

    license inquiries, in writing, to:

    IBM Director of Licensing, IBM Corporation, North Castle Drive, Armonk, NY 10504-1785 U.S.A.

    The following paragraph does not apply to the United Kingdom or any other country where such provisions

    are inconsistent with local law: INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS

    PUBLICATION "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT

    NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS

    FOR A PARTICULAR PURPOSE. Some states do not allow disclaimer of express or implied warranties in certain

    transactions, therefore, this statement may not apply to you. This information could include technical inaccuracies ortypographical errors. Changes are periodically made to the information herein; these changes will be incorporated in

    new editions of the publication. IBM may make improvements and/or changes in the product(s) and/or the program(s)

    described in this publication at any time without notice.

    Any references in this information to non-IBM Web sites are provided for convenience only and do not in any manner

    serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materials for this

    IBM product and use of those Web sites is at your own risk.IBM may use or distribute any of the information you

    supply in any way it believes appropriate without incurring any obligation to you. Information concerning non-IBM

    products was obtained from the suppliers of those products, their published announcements or other publicly

    available sources. IBM has not tested those products and cannot confirm the accuracy of performance, compatibility

    or any other claims related to non-IBM products. Questions on the capabilities of non-IBM products should be

    addressed to the suppliers of those products. This information contains examples of data and reports used in daily

    business operations. To illustrate them as completely as possible, the examples include the names of individuals,

    companies, brands, and products. All of these names are fictitious and any similarity to the names and addresses

    used by an actual business enterprise is entirely coincidental.

    Any performance data contained herein was determined in a controlled environment. Therefore, the results obtained

    in other operating environments may vary significantly. Some measurements may have been made on

    development-level systems and there is no guarantee that these measurements will be the same on generally

    available systems. Furthermore, some measurement may have been estimated through extrapolation. Actual results

    may vary. Users of this document should verify the applicable data for their specific environment.

    COPYRIGHT LICENSE:

    This information contains sample application programs in source language, which illustrate programming techniques

    on various operating platforms. You may copy, modify, and distribute these sample programs in any form without

    payment to IBM, for the purposes of developing, using, marketing or distributing application programs conforming to

    the application programming interface for the operating platform for which the sample programs are written. These

    examples have not been thoroughly tested under all conditions. IBM, therefore, cannot guarantee or imply reliability,

    serviceability, or function of these programs.

    Copyright International Business Machines Corporation 2009. All rights reserved.

    Note to U.S. Government Users Restricted Rights -- Use, duplication or disclosure restricted by

    GSA ADP Schedule Contract with IBM Corp.

  • 8/2/2019 Ds VF Extension Module

    14/14

    QLogicVirtualFabricExtensionModuleforIBMBladeCenter 14

    This document was created or updated on May 10, 2010.

    Send us your comments in one of the following ways:Use the online Contact us review form found at:

    ibm.com/redbooks

    Send your comments in an e-mail to:

    [email protected]

    Mail your comments to:

    IBM Corporation, International Technical Support Organization

    Dept. HYTD Mail Station P0992455 South RoadPoughkeepsie, NY 12601-5400 U.S.A.

    This document is available online at http://www.ibm.com/redbooks/abstracts/tips0717.html .

    Trademarks

    IBM,theIBMlogo,andibm.comaretrademarksorregisteredtrademarksofInternationalBusinessMachinesCorporationintheUnitedStates,othercountries,orboth.TheseandotherIBMtrademarkedtermsareUSregisteredorcommonlawtrademarksownedbyIBMatthetimethisinformationwaspublished.Suchtrademarksmayalsoberegisteredorcommonlawtrademarksinothercountries.AcurrentlistofIBMtrademarksisavailableontheWebathttp://www.ibm.com/legal/copytrade.shtml

    ThefollowingtermsaretrademarksoftheInternationalBusinessMachinesCorporationintheUnitedStates,othercountries,orboth:

    BladeCenterDS4000DS8000IBMRedbooksRedpaperRedbooks(logo)SystemStorageSystemxXIV

    Othercompany,product,orservicenamesmaybetrademarksorservicemarksofothers.