Dual-flow AHU
1HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 12.674 A
FLOWAY is a PLUG & PLAY dual-flow ventilation unit equipped with a highly efficient heat recovery unit with plug fans and high performance EC motors, designed to meet all the requirements of recent thermal regulations.
Unit supplied ready to use, prewired, preprogrammed in the factory and supplied with a remote control.
FLOWAY draws clean, fresh air indoors using, on average, 80% less energy than that needed for air conditioning (cooling and heating).
These machines are designed for use in the following applications:
é Service sector Buildings:
o Administrative buildings, Offices
o Education facilities, libraries, community centres
o Cafés, hotels, restaurants
o Shops
o Nursing homes, healthcare facilities
o Collective housing
é All facilities where ventilation is required.
Classic model: 9 sizes, air flow from 300 to 8500 m3/h.
Floor-mounted horizontal unit with horizontal air flows and air connections on the sides.
Vertical model: 4 sizes, air flow from 300 to 2600 m3/h.
Floor-mounted vertical unit with vertical air flows and air connections on the top.
Ceiling-mounted model: 3 sizes, air flow from 300 to 1900 m3/h.
Ceiling-mounted horizontal unit with vertical air flows and air connections on the sides.
The dual-flow air handling unit with heat recovery guaranteeing an
Economical and Durable solution
UseAir flow rate: 500 to 8500 m3/h
* These values are given as a guide for a dual-flow unit fitted as standard, without standard option (electric heater).
MODELS Nominal Flow Rate
(m3/h)Max. power*
(Kw)Max current*
(A)Voltage
(V)700 700 2 x 0.42 6,2 1-Ph 2301200 1200 2 x 0.42 6,2 1-Ph 2301600 1600 2 x 0.99 3,6 3-Ph 400
MODELS Nominal Flow Rate
(m3/h)Max. power*
(Kw)Max current*
(A)Voltage
(V)700 700 2 x 0.42 6,2 1-Ph 2301000 1000 2 x 0.42 6,2 1-Ph 2301500 1500 2 x 0.99 3,6 3-Ph 4002000 2000 2 x 0.99 3,6 3-Ph 400
MODELSNominal Flow Rate
(m3/h)Max. power*
(Kw)Max current*
(A)Voltage
(V)1000 1000 2 x 0.42 6,2 1-Ph 2301500 1500 2 x 0.99 3,6 3-Ph 4002000 2000 2 x 0.99 3,6 3-Ph 4002500 2500 2 x 1.7 5,5 3-Ph 4003000 3000 2 x 1.7 5,5 3-Ph 4004000 4000 2 x 1.85 6,1 3-Ph 4005000 5000 2 x 1.85 6,1 3-Ph 4006000 6000 2 x 2.73 8,7 3-Ph 4007500 7500 2 x 2.73 8,7 3-Ph 400
RangeFLOWAY "Classic"
FLOWAY "Vertical"
FLOWAY "Ceiling-mounted version"
-
HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 12.674 A
FLOWAY
2
Dual-flow AHU
CasingnDouble-skin panels made from sheet steel, galvanised on both sides, thickness 8/10 mm. nRAL 7035 and RAL 7024 grey lacquer coated finish on external panels.nM0/A1 fire ratingnMineral wool, thickness 50 mm.
FiltrationnF5, F7, F8 or F9 filters.nFilter cells kept compressed by a special system to ensure a leaktight seal.nFilter fouling value monitored by analogue sensor and displayed by controller.
Ventilationn"Plug Fan" type direct drive FMA. nPlug fan driven by an electronically commutated motor with built-in speed control.
Heat recovery unitsnCounter-flow plate heat exchanger with motorised partial bypass (ceiling-mounted and vertical models).é Efficiency greater than 80% across the range of air flows.
nRotary heat exchanger equipped with speed control ("Classic" model).é Efficiency greater than 80% at nominal flow rate.
Hydraulic CoilCopper pipes, aluminium fins.nCoil can be integrated or additional (cased)nWith the accessory fitted, 3-way control valve and 0-10V actuator controlled by "Floway Control" for setpoint accuracy.nGalvanised condensate drain pan (cooling coil or mixed coil only).
Electrics box n Electrics box for power, control and internal regulation of the unit, comprising:
- Power supply (3-Ph/400 V/Earth or 1-Ph/230 V/Earth).- Main disconnect switch.- Protected transformer.- Protection and control of all electrical components by a
circuit-breaker and contact switch.- Peripheral options and power terminal block.- Control by factory pre-programmed CAREL pCO3 PLC.- Hand-held cabled micro-terminal (cable length provided:
6 m).- Fault summary contact.- 3 temperature sensors.- 4 pressure sensors.
Accessories Damper with airfoil blades driven by an on/off spring-return actuator. Flexible sleeve Adjustable feet CO2 air quality sensorSound trap Roof Canopy Mixing section Indoor environment switch
Description
MODELS Power (kW) Voltage (V) Current (A)
Classic 10004,5 1-Ph 230 20Vertical 700 & 1000
Ceiling-mounted 700 & 1200Classic 1500
7,2 3-Ph 400 11Vertical 1500 (external)Ceiling-mounted 1600Vertical 1500 (internal) 8,1 3-Ph 400 12
Classic 2000 & 2500 10,8 3-Ph 400 16Classic 3000 12,6 3-Ph 400 19Classic 4000 16,8 3-Ph 400 25Classic 5000 19,8 3-Ph 400 29Classic 6000 22,8 3-Ph 400 34Classic 7500 31,2 3-Ph 400 46
Electric heatersnElectric elements encased in a copper finned layer to ensure uniform distribution of heat.nHigh-limit safety thermostat with automatic and manual reset.nControl by 2-stage on/off operation (3 stages, depending on the model) fully controlled by "Floway Control".
-
FLOW
AY
Dual-flow AHU
3HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 12.674 A
"FLOWAY CONTROL" control function (software V2.2) Included Options*
Fan Timer programming Integrated clock: management in series 4 events per year, and per week and per day X
Safety
Frost protectionBy Fresh Air Temperature control XBy Exhaust air flow pressure on heat recovery unit delta control (pressure sensor) X
Monitoring of sensor status XMonitoring operation values (thresholds) XOperating control of EC fan motor assemblies via a fault summary contact X"Control of filter fouling (automatic calculation of "Dirty filter" and "Blocked filter" alarm thresholds) XMain and ordinary fault summary XFire monitoring (potential free (dry) contact available (normally closed)) X
Alarms Management of alarms and log (100) X
Control mode
Control of return air or supply air temperature X
Regulated temperature control based on Outdoor temperature X
Control of room temperature with a room terminal (Th-Tune) X
Hot air and/or Cold air production
Gradual action on the 3V hydraulic coil control valve XGradual action on the electric heater TRIAC XOn/Off action on the various stages of the electric heaters X
Free cooling operationRotary heat exchanger stop (CLASSIC model) XOpen bypass on counter flow plate recovery unit (VERTICAL & CEILING-MOUNTED model) X
Night cooling operationRotary heat exchanger stop (CLASSIC model) XOpen bypass on counter flow plate recovery unit (VERTICAL & CEILING-MOUNTED model) X
Morning heating operation Control degree of opening of mixing bypass (CLASSIC model) X
ECO recirculation operation Control degree of opening of mixing bypass (CLASSIC model) X
Optimisation of output Variation of the rotation speed of the rotary recovery unit (CLASSIC model) X
Configuration of the air flow rate
2 air flow rate setpoints per air flow XDisplay of the air flow rate XOverpressure/negative pressure management X
Constant flow rate operation Keeps the air flow rate constant regardless of how fouled the filters are X
Modulation of flow rates operation
Single zonesignal 0-10V CO2 sensor X
contact Presence contact XExternal contact XMulti zone Intake duct constant pressure operation X
Communicating mode Management by CMS
MODBUS protocol XLON protocol XKNX protocol X
TCP/IP protocol X
Miscellaneous
Languages supported (French/English/German/Dutch/Spanish/Italian) XIntegrated temperature sensors (*3: fresh air supply and extraction, exhaust air extraction) XIntegrated pressure sensors (*4: fresh air and exhaust air filter fouling level, fresh air and exhaust air fan) XDamper control XInformation provided to the user via the hand-held micro terminal XContact for controlling the pumps for the hydraulic coils (with operating control) XContact for controlling an external outdoor heat production system (boiler, etc.) XContact for controlling a humidifier X
controlFLOWAY ControlFLOWAY features, as standard, an electrics box equipped with a factory-programmed PLC and a hand-held micro-terminal.
Option*: Requires the component to be selected as an option_damper, coil, CO2 sensor,...
-
HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 12.674 A
FLOWAY
4
Dual-flow AHU
Dimensions anD Directions of air flows
Sizes 1500 and 2000
FLOWAY "CLASSIC"
Size 1000
MODELSDIMENSIONS
WEIGHT * Height Length Width
1000 908 1360 810 2011500 1158 557+847 1010 3032000 1158 557+847 1010 3092500 1359 800+800 1210 4133000 1359 800+800 1210 4324000 1659 800+800 1510 5585000 1659 800+800 1510 6046000 1959 800+800 1810 7027500 1959 800+800 1810 751
47.2 1310
1404
303 404 302
271
467
n355
n355
1073
85
1159
421
1009
Sizes 2500 to 7500
MODELSDimensions (mm)
A B C D E
2500 1600 1210 1359 990 5103000 1600 1210 1359 990 5104000 1600 1510 1659 1284 6125000 1600 1510 1659 1284 6126000 1600 1810 1959 1584 7627500 1600 1810 1959 1584 762
AD
B
E
C
* Without internal option
-
FLOW
AY
Dual-flow AHU
5HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 12.674 A
Direction of air flow
WHITE ARROW = FRESH AIR
BLACK ARROW = EXTRACTED AIR
ROTS 1.1 ROTS 2.2
ROTS 1.2 ROTS 2.1
-
HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 12.674 A
FLOWAY
6
Dual-flow AHU
FLOWAY "VERTICAL"
Ø 16 mm condensate drain pipe
MODELSDIMENSIONS
WEIGHT *Height Length Width
700 1385 1313 730 2021000 1526 1456 730 2431500 1758 1593 832 3302000 1901 1735 832 389
Size 700
Size 1000
1270
1313
4710
012
38
13381385
702730
272
70
124
n46
492.5 584.5 193
231
239
231
193 584.5 492.5
n250 n250
n250 n250
701
7301411
4713
7910
0
1526
1479
223 660 529
222660529
231
239
231
313
70
124
1456
n315
n315
n315
n315
n46
* Without internal option
-
FLOW
AY
Dual-flow AHU
7HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 12.674 A
Size 15001550
1593805
832
4716
1110
0
17111758
7034
9
124
n46
572 730 248
253
295
253
248 730 572
n355
n355
n355
n355
1692
1735
4717
5410
0
18541901
805
832
7038
5
124
620 824 248
253
295
253
248 824 620
n46
n355
n355
n355
n355
Size 2000
WHITE ARROW = FRESH AIR
BLACK ARROW = EXTRACTED AIR
-
HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 12.674 A
FLOWAY
8
Dual-flow AHU
Ø 16 mm condensate drain pipe
Size 1200
FLOWAY "CEILING-MOUNTED VERSION"
MODELSDIMENSIONS
WEIGHTHeight Length Width
700 585 1453 896 161 1200 585 1592 1174 2061600 585 1850 1456 279
Size 700
WHITE ARROW = FRESH AIR
BLACK ARROW = EXTRACTED AIR
47149847
1592
1202
1174
1224
280938280
n
-
FLOW
AY
Dual-flow AHU
9HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 12.674 A
Size 1600
WHITE ARROW = FRESH AIR
BLACK ARROW = EXTRACTED AIR
1484
280 601 601 280
1506
1456
n13.5
1856
47176247
C C
D
71
474.5
253
A B
n16
MODELSAIR CIRCULATION DIMENSIONS (mm)
A B C D
700 306 306 Ø160 Ø315
1200 398 398 Ø250 Ø355
1600 499.5 499.5 Ø250 Ø400
-
HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 12.674 A
FLOWAY
10
Dual-flow AHU
404 405
221
321
809
504 505
1009
271
371
1210
759
1069
1810
ADDITIONAL CASING (MUST ONLY BE POSITIONED IN A HORIZONTAL AIR FLOW.)
Size 1
Size 3
Size 5
Size 2
Size 4
FLOWAY MODELS Additional casing sizeWeight
(kg)
Classic 1000Vertical 700 & 1000Ceiling-mounted 700
Size1496x809x543 49 Kg
Classic 1500 & 2000Vertical 1500 & 2000Ceiling-mounted 1200 & 1600
Size 2 495x1009x642 64 Kg
Classic 2500 & 3000Size3
400x759x1210 68 Kg
Classic 4000 & 5000Size 4
400x909x1510 88 Kg
Classic 6000 & 7500Size 5
400x1069x1810 112 Kg
1510
906793
-
FLOW
AY
Dual-flow AHU
11HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 12.674 A
0.15
0.25
0.35
500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 7500 8000 8500 9000
W/(m3/h)
m3/hm3/s0.278 0.833 1.667 2.2220.556 1.3891.111 1.944
3000
4000
5000
6000
750025001000
1500
2000
classic moDel performance
sfpby fan = f(flow)
Clean F7 filterHeat recovery unit conditions:
0°C / 90% & 20°C / 50%
Clean F7 filterHeat recovery unit conditions:
0°C / 90% & 20°C / 50%Duct pressure: 200Pa
performancerecov = f(flow)
100
1000
500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 7500 8000 8500 9000
Pa
m3/h
m3/s0.278 0.833 1.667 2.2220.556 1.3891.111 1.944
500
800
300
6000
7500
10001500
20002500
3000
4000
5000
operating pressure = f(flow)
SFPv=0.3 W/(m3/h)RT reference output
74
78
82
86
90
500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 7500 8000 8500 9000m3/h
0.278 0.833 1.667 2.2220.556 1.3891.111
%
1.944
1000
1500
2000
2500
3000
4000
5000
6000
7500
70
m3/h
-
HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 12.674 A
FLOWAY
12
Dual-flow AHU
“vertical” moDel performance
80
84
88
500 1000 1500 2000 2500 m3/h
%
700
1000
1500 2000
m3/s0.139 0.278 0.417 0.556 0.694
sfpby fan = f(flow)
0.15
0.25
0.35
500 1000 1500 2000 2500
W/(m3/h)
m3/h
700
1000
1500
2000
m3/s0.139 0.278 0.417 0.556 0.694
performancerecov = f(flow)
Clean F7 filterHeat recovery unit conditions:
0°C / 90% & 20°C / 50%
Clean F7 filterHeat recovery unit conditions:
0°C / 90% & 20°C / 50%Duct pressure: 200Pa
operating pressure = f(flow)
100
1000
500 1000 1500 2000 2500 m3/h
7001000
1500
2000
Pa
m3/s0.139 0.278 0.417 0.556 0.694
800
500
300
SFPv=0.3 W/(m3/h)RT reference output
-
FLOW
AY
Dual-flow AHU
13HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 12.674 A
ceiling moDel performance
sfpby fan = f(flow)
0.15
0.25
0.35
500 1000 1500 2000
W/(m3/s)
m3/h
7001200
1600
0.139 0.278 0.417 0.556m3/s
performancerecov = f(flow)
80
82
84
86
88
500 1000 1500 2000m3/h
700 1200
1600
0.139 0.278 0.417 0.556m3/s
%
Clean F7 filterHeat recovery unit conditions:
0°C / 90% & 20°C / 50%
Clean F7 filterHeat recovery unit conditions:
0°C / 90% & 20°C / 50%Duct pressure: 200Pa
operating pressure = f(flow)
100
1000
500 1000 1500 2000
Pa
m3/h
0.139 0.278 0.417 0.556m3/s
800
500
300
7001200
1600
SFPv=0.3 W/(m3/h)RT reference output
-
HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 12.674 A
FLOWAY
14
Dual-flow AHU
This document is not legally binding. As part of its policy for continual product improvement, CIAT reserves the right to make any technical modification it considers necessary without prior notice.
Registered address Avenue Jean Falconnier - B.P. 1401350 - Culoz - FranceTel.: +33 (0)4 79 42 42 42Fax: +33 (0)4 79 42 42 [email protected] - www.ciat.com
Compagnie Industrielle d’Applications Thermiques - S.A. with a registered capital of 26,728,480 € - R.C.S. Bourg-en-Bresse B 545 620 114
CIAT ServiceTel.: 08 11 65 98 98 (0.15 €/min)Fax: 08 26 10 13 63 (0.15 €/min)