DATASHEETDual & Single Fiber CWDM OADMData Center & Cloud ComputingInfrastruture Solutions
Data Center & Cloud Computing
REV.1.0 2018
Introduction
01CWDM OADM
FS.COM designs and offers all types of fiber optical transmission products to support Storage, Data and Telecom Networks. Our high-quality and cost-effective components allow customers to build the most cost-effective and reliable transmission networks.
If our products online can't meet your flexible requirements, FS.COM also supports different kinds of customizations, including:
Technical Specifications
Ⅷ
1
General Specifications
Ⅰ No. of Channel: 1ch, 2ch, 4ch, etc. available
Line Type: Dual/Single FiberⅢ
Line & Client Port: LC/SC/FC/ST, UPC/APC polish
Ⅴ
Special Service: Monitor/1310nm/1550nm port
Ⅵ
Ⅱ Wavelengths: Any wavelength combination from 1270nm to 1610nm
Housing:FMU/FLG/FUD plug-in module1U 19" rack mountABS pigtailed module
Ⅶ
Industrial Temperature for Outside-Plant Applications
Ⅳ Transmission Direction: East and West, East or West
CWDM OADM
I. No. of Channel & Wavelengths
2
General Specifications
CWDM Wavelengths
Defined by the ITU-T G.694.2, CWDM covers the wavelengths from 1270nm to 1610nm within 20nm channel spacing.
Color Coding for CWDM
For CWDM systems an industry standard color coding scheme is used. Color coded ports is designed to match the latches of CWDM transceivers for simplifying the installation.
Water Peak
For G.652 and G.694.2 optical fiber, the water peak occurs at 1383 ± 3nm within the telecommunication spectrum 1260 – 1625nm. Attenuation at and near the water peak can exceed 2 dB/km, so it is common practice to avoid 1390nm and 1410nm channels.
ITU channel no.
Wavelength color color coding
45 1450nm yellow orange
47 1470nm gray
49 1490nm violet
51 1510nm blue
53 1530nm green
55 1550nm yellow
57 1570nm orange
59 1590nm red
61 1610nm brown
ITU channel no.
Wavelength color color coding
27 1270nm light purple
29 1290nm sky blue
31 1310nm yellow green
33 1330nm yellow ocher
35 1350nm pink
37 1370nm beige
39 1390nm white
41 1410nm silver
43 1430nm black
CWDM OADM
II. Line Type
3
Dual Fiber Applications
Dual fiber CWDM OADM adds and drops optical signals of same wavelengths into two fibers, while letting the rest of the wavelengths bypass to the needed destination. The CWDM transceiver connected to CWDM OADM should have the same wavelength as the client port.
Take 1ch 1470-1490nm CWDM OADM as an example, the wavelength of the transceiver mainly based on the transmit wavelength of the client port on the CWDM OADM.
TX 1470nm
RX 1490nm
TX 1510nm
RX 1530nm
TX 1550nm
RX 1570nm
TX 1590nm
RX 1610nm
1470nm
1510nm
1550nm
1590nm
CWD
M M
UX &
DEM
UX
Site A
RX 1470nm
TX 1490nm
RX 1510nm
TX 1530nm
RX 1550nm
TX 1570nm
RX 1590nm
TX 1610nm
1490nm
1530nm
1570nm
1610nm
CWD
M M
UX &
DEM
UX
Site B
Single Fiber Applications
In single fiber applications, CWDM OADM adds and drops optical signals of different wavelengths into a fiber in the opposite direction. It utilizes a single fiber for both adding and droping, which reduces overall costs, and increases the capacity of the fiber.
1ch Single Fiber
Bidirectional
1470nm
1490nm
1490nm
1470nm
1490nm 1470nm
Site C
CWDM OADM
II. Transmission Direction
3
For adding/dropping CWDM channels across sites, we categorize our CWDM OADM in two groups: single-sided (East or West) and dual-sided (East and West).
If CWDM OADM adds/drops the wavelengths in one side on fiber network, it is the East or West module; On contrary, it is the East and West module.
East or West
The single-sided OADM removes one channel from the network in one direction and sends it to a local interface. The remaining channels are passed straight through to other nodes along the network.
East and West
The dual-sided OADM removes one channel from the network in one direction and sends it to a local interface in one direction. It also allows a second local port to add the same channel back onto the network fiber in the opposite direction.
TX: 1470nm-1530nm 1490nm-1530nm RX: 1490nm-1530nm
RX: 1470nm-1530nm TX: 1490nm-1530nm
1490nm-1530nm
Add:1470nm
Drop:1470nm
TX: 1470nm-1530nm 1490nm-1530nm RX: 1470nm-1530nm
RX: 1470nm-1530nm TX: 1470nm-1530nm
1490nm-1530nm
Add:1470nm
Drop:1470nm
Add:1470nm
Drop:1470nm
01CWDM OADM 4
1%
III. Special Service
Monitor Port
It is used to monitor or test the power signal, usually at a 1% ratio, 2%, 3%, 5%, etc, also available. By connecting with measurement or monitoring equipment, such as power meters, spectrum analyzer, or FMT AIU/OPD card, the signal can be inspected without interrupting the existing network.
1310nm and 1550nm Ports
The 1310nm and 1550nm are actually WDM wavelengths. Many optical transceivers, especially the CWDM and DWDM SFP/SFP+ transceiver, support long-haul transmission over these two wavelengths. By connecting with the same wavelength optical transceivers, these two ports can be used to add 1310nm or 1550nm wavelengths into existing WDM networks.
PS: If 1310nm port is added, the following CWDM wavelengths can't be added: 1270nm, 1290nm, 1310nm, 1330nm and 1350nm;If 1550nm port is added, the following CWDM wavelengths can't be added: 1510nm, 1530nm, 1550nm, 1570nm and 1590nm.
Expansion port for future capacity expansion
1310nm for 40G LR4/ER4, 100G CFP LR4
TX
RX
CWD
M M
ux &D
emux
Mux&
Demux
λ1
λn
1%RX
TX
CWD
M M
ux &D
emux
1310nm for 40G LR4/ER4, 100G CFP LR4
Expansion port for future capacity expansion
Mux&
Demux
λ1
λnCWDM OADM
01CWDM OADM
IV. Housing & Enclosure
FMU Plug-in module
1U/2U 19'' Rack Mount ABS Pigtailed module
Specifications about ABS Pigtailed module:
5
Cable Diameter: 0.9mm/2.0mm/3.0mm Pigtail Length: 0.25~2m
Connector: With/Without connectors ABS Size: 141x 115x 18mm, 120x 80x 18mm, 100x 80x 10mm
FMU 2-slot 1U Rack
200.5mm
42.3mm
215mm
250mm
431.5mm
44mm
1 2
3 4
FS.COM provides 4 different package options for CWDM OADM, including FMU/FUD plug-in module, 1U 19" rack mount, and ABS pigtailed module, as well as the matched chassis. FLG plug-in module and FLG 3-slot 1U rack can also be provided. If you need, please e-mail to [email protected].
① ②
③ ④
FUD 4-slot 1U Rack
FUD Plug-in module
200mm
20.2mm
215mm
250mm
431.5mm
44mm
250mm
431.5mm
44mm
01CWDM OADM
Industrial temperature -40 ~ 85 °C can meet the requirements of outside-plant applications. All CWDM Mux Demux devices can be customized as industrial temperature. Generally, operating temperature is -5°C~ +75°C , storage temperature is -40°C~+85°C.
6
If you need even more requirements, welcome to contact [email protected] or [email protected]. We will do our absolute best to optimize your total solution.
V. Industrial Temperature for Outside-Plant Applications
ID Description FS P/N
Customized CWDM OADM
#70425 Dual Fiber CWDM OADM COADM-DF
#70426 Single Fiber CWDM OADM COADM-SF
CWDM OADM
#50554 1 Channel 1470nm Dual Fiber CWDM OADM, East and West FMU-MCA0147
#50556 4 Channels 1470-1530nm Dual Fiber CWDM OADM, East and West FMU-MCA044753
#50572 1 Channel 1470-1490nm Single Fiber CWDM OADM, East and West FMU-MCAS014749
Product List
Technical Specifications
01CWDM OADM 7
Related Products
Fiber Optic CablesOptic WDM Transceivers FMT Multiple-Services Transport Platform
CWDM-SFPCWDM-10G SFP+CWDM-XFP10G CWDM X210G CWDM XENPAK
MTP/MPO Fiber Cables Ultra HD Fiber CablesFiber Patch CablesRuggedized Fiber CablesPre-terminated MultifiberCables
FTTx Cables and AssemblesCables Management Fiber Testers & Tools
Cable Manager & Wire DuctCable Ties
Fiber Optic CleanerFiber Tester
Fiber Splitters Fiber Distribution TerminalFTTx Transmission
OEO (WDM Transponders)OLP/OBP (Optical Protection)VOA (Optic Attenuator)
FS.COM business radiate worldwide, if you need more efficient solutions for
Data Center, Optical Transport Network, and Enterprise Network, please contact
us at [email protected]
For more information visit www.fs.com
All statements, technical information, and recommendations related to the products here are based upon information believed to be reliable or accurate. However, the accuracy or completeness thereof is not guaranteed, and no responsibility is assumed for any inaccuracies. Please contact FS for more information.
Copyright © 2009-2018 FS.COM All Rights Reserved.
FS.COM© DATA CENTER &
CLOUD COMPUTING