duct and blower door test hand calculator

Upload: sasa-nackovic

Post on 09-Mar-2016

11 views

Category:

Documents


0 download

DESCRIPTION

Duct and Blower Door Test Hand Calculator

TRANSCRIPT

  • Houseaddressorlot#:ConditionedFloorArea:

    Ducttesterlocation:Pressuretaplocation:

    Ring(ifapplicable): Open 123

    TestMethod&Standard1

    Test2

    CFM25AirHandlerPresent

    6CFM25per100sfofCFAAirHandlernotPresent

    4CFM25per100sfofCFA

    TestMethod&Standard1

    Test2

    CFM25AirHandlerPresent(TotalLeakage)

    8CFM25per100sfofCFAAirHandlerPresent(LeakagetoExterior)

    6CFM25per100sfofCFA1.TestresultsmustcomplywithoneoftheStandardsoptions.2.TestCFM25mustbeequaltoorlessthanthecalculatedtarget.

    StandardTestedCFM50

    Glossary

    SLA:Specificleakagearea

    ((______CFM50X0.055)(______CFAX144))=SLA

    _________dividedby________=SLA0.00030SLA __________

    SLA=__________

    CalculatedTarget

    .04X________CFA__________CFM25

    CalculatedTarget

    .08X________CFA__________CFM25

    CalculatedTestResult

    PostConstruction:Atornearfinalinspection.Thehomemustbecompleteenoughtopressurizethehometo25pa.

    CFM25:Cubicfeetperminuteofairleakageat25pascalsofpressure

    TotalLeakage:Aggregationoftheentiresystemsductleakageinaducttest.LeakagetoExterior:AggregationofallductsystemleakstotheexterioroftheCFAinaducttest.CFA:Conditionedfloorarea

    DucttestingCalculator(NewConstruction)

    AirLeakagetestingCalculator(BlowerDoorTest)

    CFM50:Cubicfeetperminuteofairleakageat50pascalsofpressure

    RoughIn:Afterinstallationofthecompleteairdistributionsystembutbeforeinstallationofinsulationandsheetrock.Allowsforaccesstoallductseamsandconnectionsforreevaluationofsealintegrityifstandardisnotmetinintitialtest.

    Pascal(pa):Unitofpressure

    AtRoughin(TotalLeakage)

    PostConstruction

    __________

    __________

    .06X________CFA__________CFM25

    __________

    __________

    .06X________CFA__________CFM25

  • DuctTestingCodeLanguage

    AirLeakageTestingCodeLanguage

    503.10.3Sealing:Allducts,airhandlers,filterboxes,andbuildingcavitiesusedasductsshallbesealed.JointsandseamsshallcomplywithSectionM1601.3oftheInternationalResidentialCodeorSection603.9oftheInternationalMechanicalCode.Ducttightnesstestingshallbeconductedtoverifythattheductsaresealed.Asignedaffidavitdocumentingthetestresultsshallbeprovidedtothejurisdictionhavingauthoritybythetestingagent.Whenrequiredbythebuildingofficial,thetestshallbeconductedinthepresenceofdepartmentstaff.Ducttightnessshallbeverifiedbyeitherofthefollowing:Postconstructiontest:Leakagetooutdoorsshallbelessthanorequalto6cfmper100squarefeetofconditionedfloorareaoratotalleakagelessthanorequalto8cfmper100squarefeetofconditionedfloorareawhentestedatapressuredifferentialof0.1inchesw.g.(25Pascals)acrosstheentiresystem,includingthemanufacturersairhandlerenclosure.Allregisterbootsshallbetapedorotherwisesealedduringthetest.Roughintest:Totalleakageshallbelessthanorequalto6cfmper100squarefeetofconditionedfloorareawhentestedatapressuredifferentialof0.1inchesw.g.(25Pascals)acrosstheroughedinsystem,includingthemanufacturer'sairhandlerenclosure.Allregisterbootsshallbetapedorotherwisesealedduringthetest.Iftheairhandlerisnotinstalledatthetimeofthetest,totalleakageshallbelessthanorequalto4cfmper100squarefeetofconditionedfloorarea.EXCEPTIONS:1.Ducttightnesstestisnotrequirediftheairhandlerandallductsarelocatedwithinconditionedspace.2.Ducttightnesstestisnotrequiredifthefurnaceisanondirectventtypecombustionapplianceinstalledinanunconditionedspace.Amaximumofsixfeetofconnectedductworkintheunconditionedspaceisallowed.Alladditionalsupplyandreturnductsshallbewithintheconditionedspace.DuctsoutsidetheconditionedspaceshallbesealedwithamastictypeductsealantandinsulatedontheexteriorwithR8insulationforabovegradeductsandR5

    502.4.5BuildingAirLeakageTesting: Buildingenvelopeairleakagecontrolshallbeconsideredacceptablewhentestedtohaveanairleakagelessthan0.00030SpecificLeakageArea(SLA)whentestedwithablowerdooratapressof50Pascals(0.2inchw.g.).Testingshalloccuratanytimeafterroughinandafterinstallationofpenetrationsofthebuildingenvelope,includingpenetrationsforutilities,plumbing,electrical,ventilation,andcombustionappliancesandsealingthereof.Whenrequiredbythebuildingofficial,thetestshallbeconductedinthepresenceofdepartmentstaff.TheblowerdoortestresultsshallberecordedonthecertificaterequiredinSection105.4.EXCEPTIONS:1.Additionslessthan750squarefeet.2. Oncevisualinspectionhasconfirmedthepresenceofagasket(seeSection502.4),operablewindowsanddoorsmanufacturedbysmallbusinessshallbepermittedtobesealedoffattheframepriortothetest.SpecificLeakageArea(SLA)shallbecalculatedasfollows:

    SLA =(CFM50x0.055)/(CFAx144)Where:CFM50 =Blowerdoorfanflowat50PascalpressuredifferenceCFA =ConditionedFloorAreaofthehousingunit

    Duringtesting:Exteriorwindowsanddoors,fireplaceandstovedoorsshallbeclosed,butnotsealed.Dampersshallbeclosed,butnotsealed;includingexhaust,intake,makeupair,backdraft,andfluedampers;Interiordoorsconnectingconditionedspacesshallbeopen;accesshatchestoconditionedcrawlspacesandconditionedatticsshallbeopen;doorsconnectingtounconditionedspacesshallbeclosedbutnotsealed;Exterioropeningsforcontinuousoperationventilationsystemsandheatrecoveryventilatorsshallbeclosedandsealed;Heatingandcoolingsystem(s)shallbeturnedoff;HVACductssupplyandreturnregistersshallnotbesealed.