1150 Roberts Boulevard, Kennesaw, Georgia 30144 770-429-3000 Fax 770-429-3001 | www.automatedlogic.com © Automated Logic 2016 Duct Temperature Sensors Accessory for HVAC/R We make data big. Next level building automation engineered to help you make smart decisions. Automated Logic’s Duct Temperature Sensors feature medical- grade closed cell foam to seal the probe insertion hole and to absorb vibration. Mounting tabs allow for easy installation directly to the wall of the duct. All Duct Units have etched Teflon leadwires and double encapsulated sensors to create a watertight package that can perform under real world conditions. Duct Units have probe lengths from 2” to 18”. Duct Units come standard with a 2”x4” steel J-Box but are also available with no box, or BAPI-Box 2 enclosure, or a nylon and ABS plastic BAPI-Box 4. Features Probe Lengths: 2”, 4”, 8”, 12”, and 18” Series 304 SS Probes & Double Encapsulated Sensors Closed Cell Foam Padding and Etched Teflon Leadwires Several Enclosure Styles J-Box (Standard) BAPI-Box 4 (BB4) No Box (NB) BAPI-Box 2 (BB2) No Box J-Box BAPI-Box 2 BAPI-Box 4

Upload: others

Post on 11-Oct-2020

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Duct UnitsJ-Box B16 Duct Units Duct Temperature Sensors Duct … · 2018. 7. 5. · We make data big.™ Next level building automation engineered to help you make smart decisions

1150 Roberts Boulevard, Kennesaw, Georgia 30144770-429-3000 Fax 770-429-3001 | www.automatedlogic.com© Automated Logic 2016

Duct Temperature SensorsAccessory for HVAC/R

We make data big.™

Next level building automation engineered to help you make smart decisions.

Automated Logic’s Duct Temperature Sensors feature medical-

grade closed cell foam to seal the probe insertion hole and to

absorb vibration. Mounting tabs allow for easy installation directly

to the wall of the duct. All Duct Units have etched Teflon leadwires

and double encapsulated sensors to create a watertight package

that can perform under real world conditions. Duct Units have

probe lengths from 2” to 18”.

Duct Units come standard with a 2”x4” steel J-Box but are also

available with no box, or BAPI-Box 2 enclosure, or a nylon and

ABS plastic BAPI-Box 4.

Features

• Probe Lengths: 2”, 4”, 8”, 12”, and 18”

• Series 304 SS Probes & Double Encapsulated Sensors

• Closed Cell Foam Padding and Etched Teflon Leadwires

• Several Enclosure Styles

B16 TemperatureSensors

Manufactured by Building Automation Products, Inc., 750 N. Royal Ave., Gays Mills, WI 54631 USAPh:+1-608-735-4800 • Fax:+1-608-735-4804 • E-mail:[email protected] • Web:www.bapihvac.com

Automated Logic and the Automated Logic logo are registered trademarks of Automated Logic Corporation

l Probe Lengths: 2”, 4”, 8”, 12” and 18”l Series 304 SS Probes & Double Encapsulated Sensorsl Closed Cell Foam Padding and Etched Teflon Leadwiresl Several Enclosure Styles

Single Point Duct Units feature medical-grade closed cell foam to seal the probe insertion hole and to absorb vibration. Mounting tabs allow for easy installation directly to the wall of the duct. All Duct Units have etched Teflon leadwires and double encapsulated sensors to create a watertight package that can perform under real world conditions. Duct Units have probe lengths from 2” to 18”. Custom probe lengths are also available, call for details.Duct Units come standard with a 2”x4” steel J-Box but are also available with no box, or a watertight BAPI-Box or BAPI-Box 2 enclosure or a nylon & ABS plastic BAPI-Box 4.

Duct Units

Features & OptionsNo Box

J-Box

Specifications

Rev. 01/16/15

BAPI-Box

Environmental Operation Range: Temperature: -40 oC to 100 oC Humidity: 0 to 100%, non-condensingEnclosure Material and Rating: BAPI-Box: Polycarbonate, UL94, V-0 BAPI-Box 2: Polycarbonate, UL94, V-0 BAPI-Box 4: Nylon and ABS Plastic, UL94, V-0 J-Box Model: Galv. SteelEncl. Rating: BAPI-Box or BAPI-Box 2: IP66, NEMA 4 BAPI-Box 4 Model: IP10 (IP44 with Knockout Plug) J-Box Model: IP20, NEMA 1

10K-2 Thermistor Sensor SpecificationsResistance:10 kW @ 25°C, -55°C to 150°C rangeStandard Accuracy: 0.2°C (±0.36°F) at 0 to 70°CDissipation Constant: 2.7 mW/°CStability(drift): Less than ±0.1°C (0.18°F) drift over 10 years.

BAPI-Box 2

J-Box (Standard)

No Box (NB)

BAPI-Box 2 (BB2)

BAPI-Box (BB)

BAPI-Box 4

BAPI-Box 4 (BB4)

B16 TemperatureSensors

Manufactured by Building Automation Products, Inc., 750 N. Royal Ave., Gays Mills, WI 54631 USAPh:+1-608-735-4800 • Fax:+1-608-735-4804 • E-mail:[email protected] • Web:www.bapihvac.com

Automated Logic and the Automated Logic logo are registered trademarks of Automated Logic Corporation

l Probe Lengths: 2”, 4”, 8”, 12” and 18”l Series 304 SS Probes & Double Encapsulated Sensorsl Closed Cell Foam Padding and Etched Teflon Leadwiresl Several Enclosure Styles

Single Point Duct Units feature medical-grade closed cell foam to seal the probe insertion hole and to absorb vibration. Mounting tabs allow for easy installation directly to the wall of the duct. All Duct Units have etched Teflon leadwires and double encapsulated sensors to create a watertight package that can perform under real world conditions. Duct Units have probe lengths from 2” to 18”. Custom probe lengths are also available, call for details.Duct Units come standard with a 2”x4” steel J-Box but are also available with no box, or a watertight BAPI-Box or BAPI-Box 2 enclosure or a nylon & ABS plastic BAPI-Box 4.

Duct Units

Features & OptionsNo Box

J-Box

Specifications

Rev. 01/16/15

BAPI-Box

Environmental Operation Range: Temperature: -40 oC to 100 oC Humidity: 0 to 100%, non-condensingEnclosure Material and Rating: BAPI-Box: Polycarbonate, UL94, V-0 BAPI-Box 2: Polycarbonate, UL94, V-0 BAPI-Box 4: Nylon and ABS Plastic, UL94, V-0 J-Box Model: Galv. SteelEncl. Rating: BAPI-Box or BAPI-Box 2: IP66, NEMA 4 BAPI-Box 4 Model: IP10 (IP44 with Knockout Plug) J-Box Model: IP20, NEMA 1

10K-2 Thermistor Sensor SpecificationsResistance:10 kW @ 25°C, -55°C to 150°C rangeStandard Accuracy: 0.2°C (±0.36°F) at 0 to 70°CDissipation Constant: 2.7 mW/°CStability(drift): Less than ±0.1°C (0.18°F) drift over 10 years.

BAPI-Box 2

J-Box (Standard)

No Box (NB)

BAPI-Box 2 (BB2)

BAPI-Box (BB)

BAPI-Box 4

BAPI-Box 4 (BB4)

B16 TemperatureSensors

Manufactured by Building Automation Products, Inc., 750 N. Royal Ave., Gays Mills, WI 54631 USAPh:+1-608-735-4800 • Fax:+1-608-735-4804 • E-mail:[email protected] • Web:www.bapihvac.com

Automated Logic and the Automated Logic logo are registered trademarks of Automated Logic Corporation

l Probe Lengths: 2”, 4”, 8”, 12” and 18”l Series 304 SS Probes & Double Encapsulated Sensorsl Closed Cell Foam Padding and Etched Teflon Leadwiresl Several Enclosure Styles

Single Point Duct Units feature medical-grade closed cell foam to seal the probe insertion hole and to absorb vibration. Mounting tabs allow for easy installation directly to the wall of the duct. All Duct Units have etched Teflon leadwires and double encapsulated sensors to create a watertight package that can perform under real world conditions. Duct Units have probe lengths from 2” to 18”. Custom probe lengths are also available, call for details.Duct Units come standard with a 2”x4” steel J-Box but are also available with no box, or a watertight BAPI-Box or BAPI-Box 2 enclosure or a nylon & ABS plastic BAPI-Box 4.

Duct Units

Features & OptionsNo Box

J-Box

Specifications

Rev. 01/16/15

BAPI-Box

Environmental Operation Range: Temperature: -40 oC to 100 oC Humidity: 0 to 100%, non-condensingEnclosure Material and Rating: BAPI-Box: Polycarbonate, UL94, V-0 BAPI-Box 2: Polycarbonate, UL94, V-0 BAPI-Box 4: Nylon and ABS Plastic, UL94, V-0 J-Box Model: Galv. SteelEncl. Rating: BAPI-Box or BAPI-Box 2: IP66, NEMA 4 BAPI-Box 4 Model: IP10 (IP44 with Knockout Plug) J-Box Model: IP20, NEMA 1

10K-2 Thermistor Sensor SpecificationsResistance:10 kW @ 25°C, -55°C to 150°C rangeStandard Accuracy: 0.2°C (±0.36°F) at 0 to 70°CDissipation Constant: 2.7 mW/°CStability(drift): Less than ±0.1°C (0.18°F) drift over 10 years.

BAPI-Box 2

J-Box (Standard)

No Box (NB)

BAPI-Box 2 (BB2)

BAPI-Box (BB)

BAPI-Box 4

BAPI-Box 4 (BB4)

B16 TemperatureSensors

Manufactured by Building Automation Products, Inc., 750 N. Royal Ave., Gays Mills, WI 54631 USAPh:+1-608-735-4800 • Fax:+1-608-735-4804 • E-mail:[email protected] • Web:www.bapihvac.com

Automated Logic and the Automated Logic logo are registered trademarks of Automated Logic Corporation

l Probe Lengths: 2”, 4”, 8”, 12” and 18”l l l Several Enclosure Styles

call for details.Duct Units come standard with a 2”x4” steel J-Box but are also available with no box, or a watertight BAPI-Box or BAPI-Box 2 enclosure or a nylon & ABS plastic BAPI-Box 4.

Duct Units

Features & OptionsNo Box

J-Box

Rev. 01/16/15

Environmental Operation Range: Temperature: -40 oC to 100 oC Humidity: 0 to 100%, non-condensingEnclosure Material and Rating: BAPI-Box: Polycarbonate, UL94, V-0 BAPI-Box 2: Polycarbonate, UL94, V-0 BAPI-Box 4: Nylon and ABS Plastic, UL94, V-0 J-Box Model: Galv. SteelEncl. Rating: BAPI-Box or BAPI-Box 2: IP66, NEMA 4 BAPI-Box 4 Model: IP10 (IP44 with Knockout Plug) J-Box Model: IP20, NEMA 1

sResistance:10 kΩ @ 25°C, -55°C to 150°C rangeStandard Accuracy: 0.2°C (±0.36°F) at 0 to 70°CDissipation Constant: 2.7 mW/°CStability(drift): Less than ±0.1°C (0.18°F) drift over 10 years.

BAPI-Box 2

J-Box (Standard)

No Box (NB)

BAPI-Box 2 (BB2)

BAPI-Box (BB)

BAPI-Box 4

BAPI-Box 4 (BB4)

Page 2: Duct UnitsJ-Box B16 Duct Units Duct Temperature Sensors Duct … · 2018. 7. 5. · We make data big.™ Next level building automation engineered to help you make smart decisions

We make data big.™

Next level building automation engineered to help you make smart decisions.

Duct Temperature SensorsSpecifications

02012018

1150 Roberts Boulevard, Kennesaw, Georgia 30144770-429-3000 Fax 770-429-3001 | www.automatedlogic.com

Environmental Operation Range:

Temperature Sensor: -40 °C to 100 °C

Humidity: 0 to 100%, non-condensing

10K-2 Thermistor Sensor:

• Resistance: 10 kΩ @ 25°C, -55 to 150°C range

• Standard Accuracy: 0.2°C (±0.36°F) at 0 to 70°C

• Dissipation Constant: 2.7 mW/°C

• Stability(drift): Less than ±0.1°C (0.18°F) drift over

10 years

Enclosure Material:

BAPI-Box: Polycarbonate, UL94, V-0

BAPI-Box 2: Polycarbonate, UL94, V-0

BAPI-Box 4: Nylon & ABS Plastic, UL94, V-0

J-Box Model: Galv. Steel

Enclosure Rating:

BAPI-Box or BAPI-Box 2: IP66, NEMA 4

BAPI-Box 4 Model: IP10 (IP44 with Knockout Plug)

J-Box Model: IP20, NEMA 1

Part Number Description

NSB-10K-2-D-12-BB2-A DUCT TEMP PROBE - BB2 ENCLOSURE - 12 IN. PROBE LOGO- ALC

NSB-10K-2-D-4-BB2-A DUCT TEMP PROBE - BB2 ENCLOSURE - 4 IN. PROBE LOGO - ALC

NSB-10K-2-D-8-BB2-A DUCT TEMP PROBE - BB2 ENCLOSURE - 8 IN. PROBE LOGO - ALC

NSB-10K-2-D-4-BB4-A DUCT TEMP PROBE - BB4 ENCLOSURE - 4 IN. PROBE LOGO - ALC

NSB-10K-2-D-8-BB4-A DUCT TEMP PROBE - BB4 ENCLOSURE - 8 IN. PROBE LOGO - ALC

NSB-10K-2-D-12-A DUCT TEMP PROBE - J-BOX ENCLOSURE - 12 IN. PROBE NO LOGO

NSB-10K-2-D-4-A DUCT TEMP PROBE - J-BOX ENCLOSURE - 4 IN. PROBE NO LOGO

NSB-10K-2-D-8-A DUCT TEMP PROBE - J-BOX ENCLOSURE - 8 IN. PROBE NO LOGO

NSB-10K-2-D-4-NB-10-A DUCT TEMP PROBE - NO BOX - 4 IN. PROBE - 10 FT LEADS NO LOGO

NSB-10K-2-D-4-NB-15-A DUCT TEMP PROBE - NO BOX - 4 IN. PROBE - 15 FT. LEADS NO LOGO

NSB-10K-2-D-4-NB-5-A DUCT TEMP PROBE - NO BOX - 4 IN. PROBE - 5 FT. LEADS NO LOGO

NSB-10K-2-D-8-NB-10-A DUCT TEMP PROBE - NO BOX - 8 IN. PROBE -10 FT. LEADS NO LOGO