ducted air conditioner range your comfort zone. · the kd series of ducted air conditioners offer...

12
DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.

Upload: others

Post on 05-Jul-2020

10 views

Category:

Documents


0 download

TRANSCRIPT

DUCTED AIR CONDITIONER RANGE

YOUR COMFORT ZONE.

Creating the ideal climate in different rooms throughout your home is essential for your family’s comfort.

Whether it’s a sweltering summer day or an icy winter morning, Kaden reverse cycle air conditioners allow you to regulate your home’s temperature effortlessly. This makes it the air conditioner for all seasons. Designed specifically for Australian conditions, these units deliver enduring performance matched with whisper quiet operation. Made to last, every Kaden ducted reverse cycle air conditioner comes with a full 5-year domestic warranty. All of these features make Kaden the perfect choice for versatile living.

Product Quality GuaranteeKaden ducted air conditioners offer a 5-year domestic warranty. See page 11 for further details.

5YEARQ

U

ALITY GUARANTEE

Kaden Ducted Air Conditioners

04 - Your Comfort Zone.

Kaden Ducted Air Conditioner

Benefits of ducted air conditioners

What is a Kaden reverse cycle ducted air conditioner?Designed to efficiently cool or heat an entire home, Kaden ducted reverse cycle air conditioners comprise of an indoor and outdoor unit. The indoor unit is located inside your roof and the outdoor unit can be positioned in a convenient location outside your home. These two units work together to generate cool or warm air. They are connected by piping that carries refrigerant needed to cool or heat the air.

The temperature and other settings are controlled by a wall mounted Kaden controller.

• Cool/heat an entire house

• Works well in humid environments

• Can be zoned to maximise efficiency

• A range of sizes to suit any home

The outdoor unit contains a compressor which initiates the cooling or heating process, it also has a outdoor coil and a fan.

Kaden Ducted Air Conditioner Range - 05

KD Series

Key Features The KD series of ducted air conditioners offer the ideal heating and cooling solution for your home. Incorporating the latest technology, the KD ducted series provides quiet operation in any environment. Working in ambient temperatures ranging from -15ºC to 50ºC, the KD series is perfect for the Australian environment.

Indoor unit: The indoor unit has a fan coil which conditions the supplied air, this conditioned air is then distributed through ducting in the roof to outlets in ceiling or walls.

06 - Your Comfort Zone.

Product Features

Feature Description

Automatic operation

The unit will automatically select heating or cooling mode based on the current room conditions and set temperature.

Turbo modeProvides a boost in cooling or heating power for a period of time, this allows you to reach your desired temperature quickly.

On / Off function

The unit can be set to start and /or stop at a specified time.

Weekly timer Set your unit to turn on and off at specific times for each day of the week.

Anti cold air function

Prevents cold air from blowing out to avoid discomfort when heating mode is started.

Comfort

Feature Description

DR functionFeature to enable power provider to reduce compressor speed to reduce energy consumption during periods of extreme demand. This function is disabled unless an agreement exists with your power supplier.

Auto temperature set

Allows a set preferred temperate that the unit will return to each time it is turned on.

Energy Saving

Feature Description

Easy servicing

The 7.0kW indoor unit is easily accessible from the bottom only. The 10.0kW-17.0kW is easily accessible from the top and the bottom.

Built-in drain pump

Offering a built in drain pump allowing more flexibility with installation.

Self diagnostics

If there is a part failure the unit will switch off automatically to protect yourair conditioner. An error code will appear to assist with a fast and easy fix.

Auto defrosting

Prevents the evaporator from freezing in low temperature environments.

Maintenance

Feature Description

Automatic fan speed

The unit will monitor the temperature in the room and adjust fan speed accordingly to reach the temperature quickly and efficiently.

Eccentric fan design

New eccentric fan design improves the airflow at the air outlet, resulting in better performance.

Airflow

Kaden Ducted Air Conditioner Range - 07

Features KD24 - 7.0kW

KD36 - 10.5kW

KD42 - 13.0kW

KD48 - 14.5kW

KD60 - 17.0kW

Manual external static pressure setting ✔ ✔ ✔ ✔ ✔

Automatic external static pressure setting ✔ ✔ ✔ ✔ ✔

Wired controller ✔ ✔ ✔ ✔ ✔

Wireless controller (optional) ✔ ✔ ✔ ✔ ✔

Automatic fan speed ✔ ✔ ✔ ✔ ✔

Outside air intake ✔ ✔ ✔ ✔ ✔

Filter ✔ ✘ ✘ ✘ ✘

Self diagnostics ✔ ✔ ✔ ✔ ✔

Improved serviceability ✘ ✔ ✔ ✔ ✔

Built in drain pump ✔ ✔ ✔ ✔ ✔

Turbo operation ✔ ✔ ✔ ✔ ✔

Automatic operation ✔ ✔ ✔ ✔ ✔

Weekly timer ✔ ✔ ✔ ✔ ✔

Slim design ✔ ✘ ✘ ✘ ✘

Auto restart function ✔ ✔ ✔ ✔ ✔

Anti-cold air function ✔ ✔ ✔ ✔ ✔

Auto defrosting ✔ ✔ ✔ ✔ ✔

Independent dehumidification ✔ ✔ ✔ ✔ ✔

MyZone 3 ✔ ✔ ✔ ✔ ✔

DR function ✔ ✔ ✔ ✔ ✔

08 - Your Comfort Zone.

Product Specifications

KD24 - 7.0kW KD36 - 10.5kW KD42 - 13.0kW KD48 - 14.5kW KD60 - 17.0kW

Power supply PH - V Hz 1 Ph - 220-240V - 50Hz 1 Ph - 220-240V - 50Hz 1 Ph - 220-240V - 50Hz 1 Ph - 220-240V - 50Hz 1 Ph - 220-240V - 50Hz

CapacityCooling kW 7.0 (2.8-8.4) 10.5 (4.2-12.5) 13.0 (5.0-15.5) 14.5 (5.6-16.5) 17.0 (6.8-19.5)

Heating kW 8.0 (3.0-9.0) 10.5 (4.2-12.5) 15.0 (5.0-19.0) 17.0 (5.8-20.0) 17.5 (7.0-21.0)

InputCooling kW 2.12 (0.64-2.55) 3.18 (1.25-3.80) 3.79 (1.15-4.55) 4.25 (1.29-4.25) 5.16 (1.56-5.95)

Heating kW 2.40 (0.90-2.90) 3.18 (1.25-3.80) 3.90 (1.50-5.70) 4.50 (1.70-6.20) 4.60 (2.05-6.25)

EER Cooling 3.30 3.30 3.43 3.41 3.29

COP Heating 3.33 3.30 3.85 3.78 3.80

Sound pressure levelIndoor (Turbo, High, Medium, Low) dB(A)

Turbo: 48 Turbo: 42 Turbo: 53 Turbo: 53 Turbo: 54

Hi: 45 Hi: 40 Hi: 49 Hi: 49 Hi: 49

Med: 41 Med: 37 Med: 46 Med: 45 Med: 46

Low: 38 Low: 35 Low: 42 Low: 42 Low: 42

Outdoor dB(A) 58 61 62 62 62

Sound power level Outdoor dB(A) 69 70 71 71 71

Airflow (Turbo, High, Medium, Low) l/sec

Turbo: 486 Turbo: 750 Turbo: 1,028 Turbo: 1,042 Turbo: 1,194

Hi: 389 Hi: 597 Hi: 903 Hi: 917 Hi: 1056

Med: 319 Med: 486 Med: 764 Med: 792 Med: 889

Low: 272 Low: 361 Low: 639 Low: 653 Low: 819

External static pressure Pa 0-160 0-200 0-200 0-200 0-200

External dimensions (H x W x D)

Indoor mm 248 x 1100 x 720 380 x 1200 x 625 380 x 1200 x 625 380 x 1200 x 625 440 x 1400 x 858

Outdoor mm 810 x 946 x 410 810 x 946 x 410 1333 x 952 x 415 1333 x 952 x 415 1333 x 952 x 415

Net weightIndoor kg 31 53 54 54 75

Outdoor kg 61 69 100 116 116

Refrigerant piping

Liquid line mm (inch) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”)

Gas line mm (inch) 15.90 (5/8”) 15.90 (5/8”) 15.90 (5/8”) 15.90 (5/8”) 19.00 (3/4”)

Connection Flare Connection Flare Connection Flare Connection Flare Connection Flare Connection

Refrigerant

Type R410A R410A R410A R410A R410A

Quantity kg 3.35 4.25 4.95 5.35 5.35

Precharged length m 30 30 30 30 30

Maximum pipe length m 50 65 65 65 65

Maximum pipe height m 25 30 30 30 30

Supply air connection mm 926 x 175 1000 x 253 1000 x 253 1000 x 253 1188 x 385

Return air connection mm 1001 x 228 1145 x 342 1145 x 342 1145 x 342 1188 x 385

Drain pipe mm OD 25 OD 25 OD 25 OD 25 OD 25

Outdoor operating rangeCooling ºC -15 to 50 -15 to 50 -15 to 50 -15 to 50 -15 to 50

Heating ºC -15 to 24 -15 to 24 -15 to 24 -15 to 24 -15 to 24

Kaden Ducted Air Conditioner Range - 09

KD24 - 7.0kW KD36 - 10.5kW KD42 - 13.0kW KD48 - 14.5kW KD60 - 17.0kW

Power supply PH - V Hz 1 Ph - 220-240V - 50Hz 1 Ph - 220-240V - 50Hz 1 Ph - 220-240V - 50Hz 1 Ph - 220-240V - 50Hz 1 Ph - 220-240V - 50Hz

CapacityCooling kW 7.0 (2.8-8.4) 10.5 (4.2-12.5) 13.0 (5.0-15.5) 14.5 (5.6-16.5) 17.0 (6.8-19.5)

Heating kW 8.0 (3.0-9.0) 10.5 (4.2-12.5) 15.0 (5.0-19.0) 17.0 (5.8-20.0) 17.5 (7.0-21.0)

InputCooling kW 2.12 (0.64-2.55) 3.18 (1.25-3.80) 3.79 (1.15-4.55) 4.25 (1.29-4.25) 5.16 (1.56-5.95)

Heating kW 2.40 (0.90-2.90) 3.18 (1.25-3.80) 3.90 (1.50-5.70) 4.50 (1.70-6.20) 4.60 (2.05-6.25)

EER Cooling 3.30 3.30 3.43 3.41 3.29

COP Heating 3.33 3.30 3.85 3.78 3.80

Sound pressure levelIndoor (Turbo, High, Medium, Low) dB(A)

Turbo: 48 Turbo: 42 Turbo: 53 Turbo: 53 Turbo: 54

Hi: 45 Hi: 40 Hi: 49 Hi: 49 Hi: 49

Med: 41 Med: 37 Med: 46 Med: 45 Med: 46

Low: 38 Low: 35 Low: 42 Low: 42 Low: 42

Outdoor dB(A) 58 61 62 62 62

Sound power level Outdoor dB(A) 69 70 71 71 71

Airflow (Turbo, High, Medium, Low) l/sec

Turbo: 486 Turbo: 750 Turbo: 1,028 Turbo: 1,042 Turbo: 1,194

Hi: 389 Hi: 597 Hi: 903 Hi: 917 Hi: 1056

Med: 319 Med: 486 Med: 764 Med: 792 Med: 889

Low: 272 Low: 361 Low: 639 Low: 653 Low: 819

External static pressure Pa 0-160 0-200 0-200 0-200 0-200

External dimensions (H x W x D)

Indoor mm 248 x 1100 x 720 380 x 1200 x 625 380 x 1200 x 625 380 x 1200 x 625 440 x 1400 x 858

Outdoor mm 810 x 946 x 410 810 x 946 x 410 1333 x 952 x 415 1333 x 952 x 415 1333 x 952 x 415

Net weightIndoor kg 31 53 54 54 75

Outdoor kg 61 69 100 116 116

Refrigerant piping

Liquid line mm (inch) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”)

Gas line mm (inch) 15.90 (5/8”) 15.90 (5/8”) 15.90 (5/8”) 15.90 (5/8”) 19.00 (3/4”)

Connection Flare Connection Flare Connection Flare Connection Flare Connection Flare Connection

Refrigerant

Type R410A R410A R410A R410A R410A

Quantity kg 3.35 4.25 4.95 5.35 5.35

Precharged length m 30 30 30 30 30

Maximum pipe length m 50 65 65 65 65

Maximum pipe height m 25 30 30 30 30

Supply air connection mm 926 x 175 1000 x 253 1000 x 253 1000 x 253 1188 x 385

Return air connection mm 1001 x 228 1145 x 342 1145 x 342 1145 x 342 1188 x 385

Drain pipe mm OD 25 OD 25 OD 25 OD 25 OD 25

Outdoor operating rangeCooling ºC -15 to 50 -15 to 50 -15 to 50 -15 to 50 -15 to 50

Heating ºC -15 to 24 -15 to 24 -15 to 24 -15 to 24 -15 to 24

INTERNAL UNIT CONTROLLEROUTDOOR UNIT

10 - Your Comfort Zone.

Zone Controller (optional upgrade)

Kaden is also compatible with the zoning solution Myzone 3, which gives you the ability to have precise control over each room individually. When your ducted air-conditioner is controlled by the Myzone 3, it gives you the ability to zone your house and direct the airflow to only the rooms you require.

• One device to control temperature and zones: Offers simplicity for the homeowner.

• WIFI: Control temperature from anywhere i.e. on the way home on a hot day or from your couch.

• Reliability: Less call backs for the contractor.

• Ease of use and ease of install.

• Compatible with most major brands.

Controlling your Kaden

Kaden Controller: Each Kaden ducted air conditioner comes with the Kaden controller as standard.

Features:

• Easy to read back lit display

• Weekly timer schedule

• Turbo mode operation

• Child lock

Controllers

Kaden Ducted Air Conditioner Range - 11

Residential Parts & labour

5YEARQ

U

ALITY GUARANTEE

Peace of Mind

Commercial Parts & labour

For more information go to www.kadenair.com.au/products/split-systems/ducted-air-conditioner

1YEARQ

U

ALITY GUARANTEE

Non-human comfort Parts & labour

5YEARQ

U

ALITY GUARANTEE

Due to limitations in the printing process the colours in this brochure are a guide only.

The manufacturer/distributor reserves the right to vary specifications or delete models from their range without prior notification. The manufacturer/distributor takes no responsibility for printing errors. All products enjoy a product replacement warranty. For full warranty details visit www.metalflex.com.au/kaden

V3 [BROCHURE CODE 2101566]