Duke Duke Energy Corporation McGuire Nuclear Station ft. EnetJy. 12700 Hagers Ferry Road Hunrersville, NC 28078-9340 H. B. Barron (704) 875-4800 OFFICE Vice President (704) 875-4809 FAX January 11, 2001 U. S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 ATTENTION: Document Control Desk Subject: McGuire Nuclear Station, Unit 2 Docket No. 50-370 Inservice Inspection Report End of Cycle 13 Refueling Outage Please find attached the Inservice Inspection Report for inspections conducted prior to the conclusion of the end of cycle 13 (EOC-13) refueling outage for McGuire Nuclear Station (MNS), Unit 2. This report is submitted pursuant to the filing requirements of Article IWA-6000 of Section XI of the ASME Code. Section 5.2 of the attached report lists the limited examination item numbers for which a relief request will be submitted. Limited examination relief request 01-001 is under development. Submittal of relief request 01-001 to the NRC is considered a regulatory commitment. Article IWA-6000 establishes filing requirements for inservice inspection summary reports. During a review of this report, Duke identified that the filing requirements had not been satisfied for some inspection items. Several of the documented inspection items in this report were performed during a prior outage cycle. Therefore, these items are being submitted beyond the time requirements of Article IWA-6000. A licensee corrective action program report (PIP# M-00-05032) was issued to address the administrative failure to satisfy this ASME Code filing requirement. Any questions on this matter should be directed to M. R. Wilder, MNS Licensing and Compliance, at (704) 875-5362. Sincerely, / B. Barron-- H. B. Barron

Upload: others

Post on 04-Aug-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Duke Duke Energy Corporation McGuire Nuclear Station

ft. EnetJy. 12700 Hagers Ferry Road Hunrersville, NC 28078-9340

H. B. Barron (704) 875-4800 OFFICE

Vice President (704) 875-4809 FAX

January 11, 2001

U. S. Nuclear Regulatory Commission Washington, D.C. 20555-0001

ATTENTION: Document Control Desk

Subject: McGuire Nuclear Station, Unit 2 Docket No. 50-370 Inservice Inspection Report End of Cycle 13 Refueling Outage

Please find attached the Inservice Inspection Report for inspections

conducted prior to the conclusion of the end of cycle 13 (EOC-13)

refueling outage for McGuire Nuclear Station (MNS), Unit 2. This

report is submitted pursuant to the filing requirements of Article

IWA-6000 of Section XI of the ASME Code.

Section 5.2 of the attached report lists the limited examination item

numbers for which a relief request will be submitted. Limited

examination relief request 01-001 is under development. Submittal of

relief request 01-001 to the NRC is considered a regulatory

commitment.

Article IWA-6000 establishes filing requirements for inservice

inspection summary reports. During a review of this report, Duke

identified that the filing requirements had not been satisfied for

some inspection items. Several of the documented inspection items in

this report were performed during a prior outage cycle. Therefore,

these items are being submitted beyond the time requirements of

Article IWA-6000. A licensee corrective action program report (PIP#

M-00-05032) was issued to address the administrative failure to

satisfy this ASME Code filing requirement.

Any questions on this matter should be directed to M. R. Wilder, MNS

Licensing and Compliance, at (704) 875-5362.

Sincerely,

/ B. Barron--

H. B. Barron

Page 2: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

U.S. Nuclear Regulatory Commission January 11, 2001 Page 2

Attachment

cc w/o att: Mr. L. A Reyes Regional Administrator, Region II U. S. Nuclear Regulatory Commission 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323

Mr. F. Rinaldi, Project Manager Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission One White Flint North, Mail Stop 9H3 Washington, D.C. 20555

S. M. Shaeffer Senior NRC ResidentInspector McGuire Nuclear Station

Page 3: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

U.S. Nuclear Regulatory Commission January 11, 2001 Page 3

bxc w/att: ELL (EC050) Master File: 1.3.8.1 - Routine Reports R.L. Gill, Jr. (ECl2R)

bxc w/o att: Kay L. Crane (MG01RC) Gary D. Gilbert (CN01RC) Charles J. Thomas (EC050) Lisa Vaughn (PB05E) Larry E Nicholson (ON03RC) R.K. Rhyne (EC07J) R. Branch (MG01MM)

Page 4: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

pages 140

FORM NIS-1 OWNER'S DATA REPORT-FOR INSERVICE INSPECTIONS

As required by the Provisions of the ASME Code Rules

1. Owner:Duke Energy Corporation, 526 S. Church St., Charlotte, NC 28201-1006

(Name and Address of Owner)

2 Plant: McGuire Nuclear Station. Highway 73 Cowans Ford. N.C. 28216

3

5.

(Name and Address of Plant)

Plant Unit: 2 4. Owner Certificate of Authorization (if required) N/A

Commercial Service Date: March 1.1984 .6. National Board Number for Unit -4:

7. Components Inspected:

Component or Appurtenance

Manufacturer or Manufacturer or State or Installer Installer Serial. Province No.

No.

See Section 1.1 in the Attached Report

Note: Supplemental sheets in form of lists, sketches, or drawings may be used provided (1) size is 8'112fTi- x.

11 in., (2) information in items 1 through 6 on this data report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

National Board No..

Page 5: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-1 (Back)

8. Examination Dates April 16, 1999 to October 13, 2000

9. Inspection Period Identification:

10. Inspection Interval Identification:

11. Applicable Edition of Section XI

12. Date/Revision of Inspection Plan:

Second Period

Second Interval

1989 Addenda None

September 7, 1999/Revision 3

13. Abstract of Examinations and Test. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan. See Sections 3.0. 4.0 and 11.0

14. Abstract of Results of Examination and Tests.

15. Abstract of Corrective Measures.

See Section 5.0 and 11.0

See Section 8.0

We certify that a) the statements made in this report are correct b) the examinations and tests meet the Inspection Plan as required by the ASME Code, Section XI, and c) corrective measures taken conform to the rules of the ASME Code, Section XI.

Certificate of Authorization No. (if applicable)

Date -•2e: J Signed Duke Enera\Owner

N/A Expiration Date

vo Cor. By X 1, LP

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commisnion issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Province of "6L"-r'4 .- .hL(&JA employed by * The HSBI&I Co. of HI -r- . cr have inspected the components described in this Owners' Report during the

period i.. $... . to 0-•"90 , and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in the Owners' Report in accordance with the Inspection Plan and as required by the ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, test, and corrective measures described in this Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection

___Commissions I'J 77(i3, to./ A) -2Inspect Is Signature

Date /&Ii

National Board, State, Province, and -naorsements

* The Hartford Steam Boiler Inspection & Insurance Co. 200 Ashford Center North Suite 300 Atlanta, GA. 30338

N/A

L

Ili I I I 0>

Page 6: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

INSERVICE INSPECTION REPORT UNIT 2 MCGUIRE 2000

OUTAGE 5/EOC-13

Location: Hwy. 73, Cowans Ford, North Carolina 28216

NRC Docket No. 50-370

National Board No. 84

Commercial Service Date: March 1, 1984

Owner: Duke Energy Corporation 526 South Church St.

Charlotte, N.C. 28201-1006

Revision 0

Prepared By:

Reviewed By:

Approved By:

Date \ Z. I |zo0

Date /12 1q Zoo

Date jz 1 6-

Page 7: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

DISTRIBUTION LIST

Duke Energy Corporation Quality Assurance Technical Services (Original Copy

McGuire Mechanical Maintenance/ QA Technical Support

NRC Document Control

Hartford Steam Boiler Inspection and Insurance Company (AIA); ANII/McGuire

State of North Carolina Department of Labor c/o J. M. Givens, Jr.

Nuclear GO Regulatory & Industrial Affairs c/o Laura Burba Mail Code/ EC050

Page 8: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

TABLE OF CONTENTS

Section Title Revision

1. General Information 0

2. Summary of Inservice Inspections 0

3. Second Ten Year Inspection Status 0

4. Final Inservice Inspection Plan 0

5. Results of Inspections Performed 0

6. Reportable Indications 0

7. Personnel, Equipment, and Material Certifications 0

8. Corrective Action 0

9. Reference Documents 0

10. Class 1 (Tab A) and 2(Tab B) Repairs and Replacements 0

11. Pressure Testing 0

Page 9: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

1.0 General Information

This report describes the Inservice Inspection of Duke Energy Corporation's McGuire Nuclear Station Unit 2 during Outage 5/EOC-13. This is the Third Outage of the Second Inspection Period of the Second Ten Year Interval.

Included in this report are the final Inservice Inspection Plan, the inspection results for each item, a summary for each category of examination and corrective action taken when unacceptable conditions were found. In addition, there is a section included for repairs and replacements required since April 16, 1999.

1.1 Identification Numbers

Manufacturer National Manufacturer or Installer State or Board

Item or Installer Serial No. Province No. No.

Reactor Vessel Rotterdam 30664 NC-201819 -

Pressurizer Westinghouse 1491 NC-201818 W1 0285

Steam Generator 2A BWI 7700-02 NC-302674 159

Steam Generator 2B BWI 7700-04 NC-302675 161

Steam Generator 2C BWI 7700-01 NC-302676 158

Steam Generator 2D BWI 7700-03 NC-302677 160

Centrifugal Pacific Pumps 2A - 48584 N/A 25 Charging Pump 2B1- 48585 28

Containment Spray Heat Delta Southern Co. 2A-35005-73-3 NC-234203 3396 Exchanger 2B-35005-73-4 NC-201822 3397

Outage 5/EOC-13 McGuire Unit 2 Section 1

Page 1 of 4 Revision 0 December 6, 2000

Page 10: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Identification NumbersContinued

Outage 5/EOC-13 McGuire Unit 2 Section 1

Page 2 of 4 Revision 0 December 6, 2000

Manufacturer National Manufacturer or Installer State or Board

Item or Installer Serial No. Province No. No.

Excess Letdown Heat Westinghouse 1810 NC-234264 1555 Exchanger

Letdown Heat Exchanger Joseph Oat & Sons, Inc. 2049-2B NC-201842 553

Reciprocating Charging Union Pump Co. N721031 B-604 N/A 80 Pump

2A 5-114E841G02 Reactor Coolant Pump Westinghouse 2B 6-114E841 G02 N/A N/A

2C 7-114E841G02 2D 8-114E841G02

Reciprocating Charging Metal Bellows Company 74730-002 N/A 002 Pump Accumulator

Reciprocating Charging Richmond Engineering N-2409.20 N/A 75220 Pump Suction Stabilizer Supply Co.

Residual Heat Joseph Oat & Sons, Inc. 2A 2046-2C NC-169800 637 Removal Heat 2B 2046-2D NC-201823 638 Exchanger

Safety Injection Pump Pacific Pumps 2A 49357 N/A 130 2B 49358 131

Regenerative Heat Joseph Oat & Sons, Inc. 2047-2B NC-201817 628 Exchanger 629

630

Seal Water Heat Atlas Industrial 1767 NC 201827 1549 Exchanger Manufacturing Company

Seal Water AMF Cuno 2A -20 N/A 4364 Injection Filter 2B - 22 4365

1.1

Page 11: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

1.1 Identification NumbersContinued

Manutacturer Manufacturer or Installer State or National

Item or Installer Serial No. Province No. Board No.

Main Steam Supply to Duke Power Co. SA N/A 62 Auxiliary Equipment System

Containment Air Duke Power Co. VQ N/A 56 Release and Addition System

Main Steam System Duke Power Co. SM NIA 70

Main Steam Vent to Duke Power Co. SV N/A 67 Atmosphere System_

Reactor Coolant Duke Power Co. NC N/A 82 System

Liquid Waste Recycle Duke Power Co. WL N/A 76 System

Refueling Water Duke Power Co. FW N/A 54 System

Auxiliary Feedwater Duke Power Co. CA N/A 73 System

Residual Heat Duke Power Co. ND N/A 63 Removal System

Nuclear Service Water Duke Power Co. RN N/A 60 System

Chemical & Volume Duke Power Co. NV N/A 80 Control System

Component Cooling Duke Power Co. KC N/A 78 System

Main Feedwater Duke Power Co. CF N/A 61 System

Containment Spray Duke Power Co. NS N/A 69 System IIIII

Outage 5/EOC-13 McGuire Unit 2 Section 1

Page 3 of 4 Revision 0 December 6, 2000

Page 12: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

1.1 Identification Numbers Continued

Manufacturer Manufacturer or Installer State or National

Item or Installer Serial No. Province No. Board No.

Containment Duke Power Co. RV N/A 72 Ventilation Cooling Water System

Safety Injection System Duke Power Co. NI N/A 83

Unit 2 Duke Power Co. N/A N/A 84

1.2 Authorized Nuclear Inservice Inspector(s)

Name: R. D. Klein

Employer: The Hartford Steam Boiler Inspection & Insurance Company

Business The Hartford Steam Boiler Inspection & Insurance Co.

Address: 200 Ashford Center North Suite 300 Atlanta, GA 30338

Outage 5/EOC-13 McGuire Unit 2 Section 1

Page 4 of 4 Revision 0 December 6, 2000

Page 13: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

2.0 Summary of Inservice Inspections

The information shown below provides an abstract of ASME Section XI Class 1, Class 2, and Augmented Items scheduled and examined during Outage 5/EOC-1 3 at McGuire Nuclear Station Unit 2.

2.1 Class 1 Inspection

Examination Category B-A Pressure Retaining Welds in Reactor Vessel

item Description Total Examined

Number During Outage

B01.010 Shell Welds

B01.011 Circumferential 0

B01.012 Longitudinal N/A

B01.020 Head Welds

B01.021 Circumferential 0

B01.022

B01.030

B01.040

B01.050

B01.051

TOTALS

Meridional

Shell-to-Flange Welds

Head-to-Flange Welds

Repair Welds

0

0

0

Beltline Region N/A

0

Outage 5/EOC-13 McGuire Unit 2 Section 2

Page 1 of 19 Revision 0 December 6, 2000

I -

Page 14: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Exami

Outage 5/EOC-13 McGuire Unit 2 Section 2

Page 2 of 19 Revision 0 December 6, 2000

nation Category B-B Pressure Retaining Welds in Vessels Other than Reactor Vessels

Item Description Total Examined

Number During Outage

Pressurize B02.01 0 Shell-to-Head Welds

B02.011 Circumferential 0

B02.012 Longitudinal

B02.020 Head Welds

B02.021 Circumferential N/A

B02.022 Meridional N/A

(Primary Side)

B02.030 Head Welds

B02.031 Circumferential N/A

B02.032 Meridional N/A

B02.040 Tubesheet-to-Head Weld 0

Heat Exchangers (Primary Side) -- Head

B02.050 Head Welds

B02.051 Circumferential N/A

B02.052 Meridional N/A

Heat Exchangers ' ~~(primary Side) -- Shell ...

B02.060 Tubesheet-to-Head Welds N/A

B02.070 Longitudinal Welds N/A

B02.080 Tubesheet-to-Shell Welds N/A

TOTALS 0

Page 15: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Examination Category B-D Full Penetration Welds of Nozzles in Vessels Inspection Program B

item Description Total Examined0 ....Number , During Outage

PReactor Vessel

B03.090 Nozzle-to-Vessel Welds 0

B03.100 Nozzle Inside Radius Section 0 S.......... .. Pressurizer . .

B03.1 10 Nozzle-to-Vessel Welds 0

B03.120 Nozzle Inside Radius Section 0

S.. )_. Steam Generators (Primary Side)

B03.130 Nozzle-to-Vessel Welds N/A

B03.140 Nozzle Inside Radius Section 0

B03.150 Nozzle-to-Vessel Welds N/A

B03.160 Nozzle Inside Radius Section N/A

TOTALS 0

Examination Category B-E Pressure Retaining Partial Penetration Welds in Vessels

REFERENCE SECTION 11.0 OF THIS REPORT

Outage 5/EOC-13 McGuire Unit 2 Section 2

Page 3 of 19 Revision 0 December 6, 2000

Page 16: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Examination Category B-F Pressure Retaining Dissimilar Metal Welds

Item Description Total Examined Number During Outage

Reactor Vessel

B05.010 Nominal Pipe Size 4" or Larger 0 Nozzle-to-Safe End Butt Welds

B05.020 Nominal Pipe Size Less Than 4" N/A Nozzle-to-Safe End Butt Welds

B05.030 Nozzle-to-Safe End Socket Welds N/A

Pressurizer

B05.040 Nominal Pipe Size 4" or Larger 0 Nozzle-to-Safe End Butt Welds

B05.050 Nominal Pipe Size Less Than 4" N/A Nozzle-to-Safe End Butt Welds

B05.060 Nozzle-to-Safe End Socket Welds N/A

Steam Generator

B05.070 Nominal Pipe Size 4" or Larger 0 Nozzle-to-Safe End Butt Welds

B05.080 Nominal Pipe Size Less Than 4" N/A Nozzle-to-Safe End Butt Welds

B05.090 Nozzle-to-Safe End Socket Welds N/A

Heat Exchangers

B05.100 Nominal Pipe Size 4" or Larger N/A Nozzle-to-Safe End Butt Welds

B05.110 Nominal Pipe Size Less Than 4" N/A Nozzle-to-Safe End Butt Welds

605.120 Nozzle-to-Safe End Socket Welds N/A

Outage 5/EOC-13 Page 4 of 19

McGuire Unit 2 Revision 0

Section 2 December 6, 2000

Page 17: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Examination Category B-F

Piping

B05.130 Nominal Pipe Size 4" or Larger Dissimilar Metal Butt Welds

0

B05.140 Nominal Pipe Size Less Than 4" N/A Dissimilar Metal Butt Welds

B05.150 Dissimilar Metal Socket Welds N/A

TOTALS 1 0

Examination Category B-G-1 Pressure Retaining Bolting, Greater Than 2" in Diameter

Item Description Total Examined Number During Outage

Reactor Vessel

B06.010 Closure Head Nuts 0

B06.020 Closure Studs (in place) 0

B06.030 Closure Studs (when removed) 0

B06.040 Threads in Flange 0

B06.050 Closure Washers, Bushings 0

Pressurizer

B06.060 Bolts and Studs N/A

B06.070 Flange Surface (when connection N/A disassembled)

B06.080 Nuts, Bushings, and Washers N/A

S~Steam Generators

B06.090 Bolts and Studs 0

B06.100 Flange Surface (when connection *8 disassembled)

B06.110 Nuts, Bushings, and Washers 0

Outage 5/EOC-13 McGuire Unit 2 Section 2

Page 5 of 19 Revision 0 December 6, 2000

(Continued)

Page 18: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Examination Category B-G-1

Heat Exchangers

B06.120 N/A

B06.130 Flange Surface (when connection N/A disassembled)

B06.140 Nuts, Bushings, and Washers N/A

• • Piping

B06.150 Bolts and Studs N/A

B06.160 Flange Surface (when connection N/A disassembled)

B06.170 Nuts, Bushings, and Washers N/A

Pumps

B06.180 Bolts and Studs 0

B06.190 Flange Surface1 0 (when connection disassembled)

B06.200 Nuts, Bushings, and Washers N/A

Valves

B06.210 Bolts and Studs N/A

B06.220 Flange Surface1 N/A (when connection disassembled)

B06.230 Nuts, Bushings, and Washers N/A

TOTALS *8

Items disassembled will be examined but will not be counted in the totals or percentages for the B-G-1 category. These items will be listed in sections 4 and 5 of the applicable report.

* These items were examined but will not be counted in the totals. Examinations performed during

the third period will be credited for report totals.

Outage 5/EOC-13 McGuire Unit 2 Section 2

Page 6 of 19 Revision 0 December 6, 2000

Bolts and Studs

(Continued)

Page 19: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Examination Category B-G-2 Pressure Retaining Bolting, 2" and Less in Diameter

Item Numbc

Description Total Examined Durina Outaae

Reactor Vessel

B07.010 Bolts, Studs, and Nuts

* A.Pressurizer

B07.020 Bolts, Studs, and Nuts

Steam Generators

B07.030 Bolts, Studs, and Nuts

Heat Exchangers

B07.040 Bolts, Studs, and Nuts

Piping

B07.050 Bolts, Studs, and Nuts

SPumps

B07.060 Bolts, Studs, and Nuts

CValvesing

B07.070 Bolts, Studs, and Nuts CRD Housing

B07.080 Bolts, Studs, and Nuts in CRD

Housing when disassembled 2

TOTALS

N/A

n

N

0 1

N

0

1

2 Items disassembled will be examined but will not be counted in the totals or percentages for the B-G-2

category. These items will be listed in sections 4 and 5 of the applicable report.

Outage 5/EOC-13 McGuire Unit 2 Section 2

Page 7 of 19 Revision 0 December 6, 2000

I

Page 20: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Integral Attachments for VesselsExamination Category B-H

Total Examined Irfrinn OItari

Reactor Vessel

Integrally Welded Attachments 0

Pressurizer

I Integrally Welded Attachments 0

Steam Generators

RnR n(0 IIntegrally Welded Attachments

Heat Exchangers

B08.040 Integrally Welded Attachments N/A

TOTALS 0

Examination Category B-J Pressure Retaining Welds in Piping

Item Description Total Examined

Number During Outage

B09.010 Nominal Pipe Size 4" or Larger

B09.011 Circumferential Welds 15

B09.012 Longitudinal Welds 3 N/A

B09.020 Nominal Pipe Size Less than 4"

B09.021 Circumferential Welds 0

B09.022 Longitudinal Welds 3 N/A

Outage 5/EOC-13 McGuire Unit 2 Section 2

Page 8 of 19 Revision 0 December 6, 2000

Item Number

N/A

DescriptionI

I

I

Page 21: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Examination Category B-J

B09.030

R0g.031

Branch Pipe Connection Welds

Nominal Pipe Size 4" or Larger 0

B09.032 Less than Nominal Pipe Size 4" 0

B09.040 Socket Welds 10

TOTALS 25

3 Longitudinal welds in Examination Category B-J that intersect circumferential welds are examined per Code Case N-524.

Examination Category B-K-1

Item

B10.010

Description

Piping

Inte-qrally Welded Attachments

Pumps

Integrally Welded Attachments

Valves

B 10.030 Integrally Welded Attachments N/A

TOTALS N/A

Outage 5/EOC-13 McGuire Unit 2 Section 2

Page 9 of 19 Revision 0 December 6, 2000

Integral Attachments for Piping,

Pumps and Valves

Total Examined nrr}•nen i tiH rv I

N/A

(Continued)

I

I

Page 22: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Examination Category B-L-l, B-M-1

B-L-2, B-M-2

Item Number

Pressure Retaining Welds in Pump Casings and Valve Bodies

Pump Casings and Valve Bodies

Description

Pumps

Total Examined f -l " nfrmý IwAz~~

Pump Casing Welds (B-L-l)

Pump Casing (B-L-2) (when disassembled for Maintenance Repair or Volumetric Examination)

N/A

0

Valves

B12.030 Valves, Nominal Pipe Size Less than 4" Valve Body Welds (B-M-1)

N/A

B12.040 Valves, Nominal Pipe Size 4" or N/A Larger Valve Body Welds (B-M-l)

B12.050 Valve Body, Exceeding 4" Nominal 0 Pipe Size (B-M-2)

TOTALS 0

Examination Category B-N-1 Interior of Reactor Vessel

B-N-2 Integrally Welded Core Support Structures and Interior Attachments to Reactor Vessels

B-N-3 Removable Core Support Structures

Item Description Total Examined Number During Outage

Reactor Vessel

B13.010 Vessel Interior (B-N-1) 0

Outage 5/EOC-13 McGuire Unit 2 Section 2

Page 10 of 19 Revision 0 December 6, 2000

I

Page 23: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Examination Category B-N-l, B-N-2, B-N-3 (Continued)

Reactor Vessel (PWR)

B13.050 Interior Attachments Within the Beitline Regcion (B-N-2)

N/A

B13.060 Interior Attachments Beyond Beltline 0 Region (B-N-2)

B13.070 Core Support Structure (B-N-3) 0

TOTALS 1 0

Examination Category B-O Pressure Retaining Welds in Control Rod Housings

Item Description Total Examined

Number During Outage

Reactor Vessel

B14.010 Welds in CRD Housing 0

TOTALS 0

Examination Category B-P All Pressure Retaining Components

REFERENCE SECTION 11.0 OF THIS REPORT

Outage 5/EOC-13 McGuire Unit 2 Section 2

Page 11 of 19 Revision 0 December 6, 2000

Page 24: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Examination Category B-Q

Note: Steam Generator Tubing is examined and documented by the Steam Generator Maintenance Group of the Station Support Division as required by the Station Technical Specifications and is not included in this report.

Examination Category F-A Class I Component Supports

Outage 5/EOC-13 McGuire Unit 2

Section 2

Page 12 of 19 Revision 0 December 6, 2000

Item Description Total Examined Number During Outage

F01.010 Class 1 Piping Supports (Code Case 2 N-491 applies) Reference Section 4.0 of this report

TOTALS 1 2

Steam Generator Tubing

Page 25: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

2.2 Class 2 Inspections

Examination Category C-A Pressure Retaining Welds in Pressure Vessels

Item Description Total Examined Number During Outage

C011.010 Shell Circumferential Welds 0

C01.020 Head Circumferential Welds 0

C01.030 Tubesheet-to-Shell Weld 2

TOTALS 2

Examination Category C-B Pressure Retaining Nozzle Welds in Vessels

Item Description Total Examined Number During Outage

C02.010 Nozzles in Vessels < 1/2" Nominal Thickness I

C02.011 Nozzle-to-Shell (or Head) Weld 0

C02.020 Nozzles Without Reinforcing Plate in Vessels >1/2" Nominal Thickness

C02.021 Nozzle-to-Shell (or Head) Weld 1

C02.022 Nozzle Inside Radius Section ' 0

Outage 5/EOC-13 McGuire Unit 2 Section 2

Page 13 of 19 Revision 0

December 6, 2000

Page 26: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Examination Category C-B

C02.030

C02.031

(Continued)

Nozzles With Reinforcing Plate in Vessels >1/2" Nominal Thickness

Reinforcing Plate Welds to Nozzle and Vessel

0

C02.032 Nozzle-to-Shell (or Head) Welds N/A when Inside of Vessel is Accessible

C02.033 Nozzle-to-Shell (or Head) Welds 0

when Inside of Vessel is Inaccessible 1 _1

TOTALS _________________________________1

4 (Item # C02.022) Nozzle Inside Radius Section welds are examined as required by Table IWC2500-1 Category C-B. However, for reporting purposes, the totals do not reflect the number of Nozzle Inside Radius Section welds examined during this outage. Nozzle Inside Radius Section welds are to be examined in conjunction with C02.021. examinations.

Examination Category C-C Integral Attachments for Vessels, Piping, Pumps, and Valves

Description

Pressure Vessels

Total Examined nrfflrnrir"r Ia•i nif

I Integral Welded Attachments

Piping

Integrally Welded Attachments

Pumps

Integrally Welded Attachments

Valves

C03.040 Integrally Welded Attachments N/A

TOTALS 1

Outage 5/EOC-13 McGuire Unit 2 Section 2

Page 14 of 19 Revision 0 December 6, 2000

Item umber

N

I

N

I

II .N N-winn

Page 27: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Examination Category C-D

Item ,.njhnI

Pressure Retaining Bolting Greater Than 2" in Diameter

Description Total Examined frnrinn Mifmtnaf

Pressure Vessels

C04.01 0 Bolts and Studs

Piping

C04.020 I Bolts and Studs

Pumps

Bolts and Studs

Valves

C04.040 Bolts and Studs N/A

TOTALS N/A

Examination Category C-F-1 Pressure Retaining Welds in Austenitic Stainless Steel or High Alloy Piping

Item Description Total Examined Number During Outage

C05.010 Piping Welds > 3/8" Nominal Wall Thickness for Piping > Nominal Pipe Size 4"

C05.011 Circumferential Weld 12

C05.012 Longitudinal Weld5 See Code Case N-524

Outage 5/EOC-13 McGuire Unit 2 Section 2

Page 15 of 19 Revision 0 December 6, 2000

N/A

I

I

Page 28: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Examination Category C-F-1

C05.020

C05.021

Piping Welds > 1/5" Nominal Wall Thickness for Piping _> Nominal Pipe Size 2" and < Nominal Pipe Size 4"

Circumferential Weld 8

C05.022 Longitudinal Weld' N/A

C05.030 Socket Welds 5

C05.040 Pipe Branch Connections of Branch Piping > Nominal Pipe Size 2"

C05.041 Circumferential Weld 0

C05.042 Longitudinal Weld5 N/A

TOTALS 25

5Longitudinal welds in Examination Categories C-F-1 and C-F-2 that intersect circumferential welds are examined per Code Case N-524.

Examination Category C-F-2 Pressure Retaining Welds in Carbon or Low Alloy Steel Piping

Item Description Total Examined Number During Outage

C05.050 Piping Welds _> 3/8" Nominal Wall Thickness for Piping > Nominal Pipe Size 4"

C05.051 Circumferential Weld 11

C05.052 Longitudinal Weld5 See Code Case N-524

Outage 5/EOC-13 McGuire Unit 2 Section 2

Page 16 of 19 Revision 0 December 6, 2000

(Continued)

Page 29: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Examination Category C-F-2

C05.060

f'lO( ORI(R

Piping Welds > 1/5" Nominal Wall Thickness for Piping > Nominal Pipe Size 2" and <_ Nominal Pipe Size 4"

Circumferential Weld N/A

C05.062 Longitudinal Weld5 N/A

C05.070 Socket Welds N/A

C05.080 Pipe Branch Connections of Branch Piping > Nominal Pipe Size 2"

C05.081 Circumferential Weld N/A

C05.082 Longitudinal Weld5 N/A

TOTALS 11

5Longitudinal welds in Examination Categories C-F-1 and C-F-2 that intersect circumferential welds

are examined per Code Case N-524.

Examination Category C-G Pressure Retaining Welds in Pumps and Valves

Item Description Total Examined Number During Outage

Pumps

C06.010 Pump Casing Welds N/A

Valves

C06.020 Valve Body Welds 0

TOTALS 0

Examination Category C-H All Pressure Retaining Components

REFERENCE SECTION 11.0 OF THIS REPORT

Outage 5fEOC-13 McGuire Unit 2 Section 2

Page 17 of 19 Revision 0 December 6, 2000

(Continued)

Page 30: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Class 2 Component Supports

Item Description Total Examined Number During Outage

F01.020 Class 2 Piping Supports (Code Case 10 N-491 applies) Reference Section 4.0 of this report

TOTALS _ 10

Examination Category F-A Supports Other than Piping Supports

Item Description Total Examined Number During Outage

F01.040 Supports other than Piping Supports 2 Class 1, 2, & 3 (Code Case N-491 applies) Reference Section 4.0 of this report

TOTALS 2

Examination Category Component Supports Class 1, 2, & 3

Item Description Total Examined Number During Outage

F01.050 Component supports snubbers Class * N/A •1,2& 3

TOTALS * N/A

• Examinations to be performed per Request for Relief 97-005

Outage 5/EOC-13 McGuire Unit 2 Section 2

Page 18 of 19 Revision 0 December 6, 2000

Examination Category F-A

Page 31: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

2.3 Augmented Inspection

Item Total Examined Number Description During Outage

G01.001 RCP Flywheel Exam 0

G03.001 Pipe Rupture Protection 0

TOTALS 0

Outage 5/EOC-13 McGuire Unit 2 Section 2

Page 19 of 19 Revision 0 December 6, 2000

Page 32: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

3.0 Second Ten Year Interval Inspection Status

The completion status of inspections required by the 1989 ASME Code Section XI, no Addenda is summarized in this section. The requirements are listed by the ASME Section Xl Examination Category as defined in Table IWB-2500-1 for Class 1 Inspections, Table IWC-2500-1 for Class 2 Inspections, and IWF-25001(Code Case N-491 applies) for Class 1, 2 and 3 Component Supports. Augmented inspections are also included.

Class I Inspections

Examination Description Inspections Inspections Percentage 6Deferral Category Required Completed Completed Allowed

B-A Pressure Retaining Welds 15 3 20.00% Yes in Reactor Vessel

B-B Pressure Retaining Welds 5 3 60.00% No in Vessels Other than Reactor Vessels

B-D Full Penetration Welds of 36 22 61.11% Partial Nozzles in Vessels Inspection Program B

B-E Pressure Retaining Partial Penetration Welds in Vessels REFERENCE SECTION 11.0 OF THIS REPORT

B-F Pressure Retaining 38 24 63.15% No Dissimilar Metal Welds

B-G-1 Pressure Retaining Bolting 241 159 65.97% No Greater than 2" in Diameter

B-G-2 Pressure Retaining Bolting 22 14 63.63% No 2" and Less in Diameter I j

Outage 5/EOC-13 McGuire Unit 2 Section 3

Page 1 of 5 Revision 0 December 6, 2000

Page 33: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Class I Inspections (Continued)

Examination Description Inspections Inspections Percentage 6Deferral Category Required Completed Completed Allowed

B-H Integral Attachments for 12 7 58.33% No Vessels

B-J Pressure Retaining Welds 197 125 63.45% No in Piping

B-K-1 Integral Attachments for N/A N/A N/A No Piping, Pumps and Valves

B-L-1 Pressure Retaining Welds N/A N/A N/A Yes in Pump Casings

B-L-2 Pump Casings 1 0 00.00% Yes

B-M-1 Pressure Retaining N/A N/A N/A Yes Welds in Valve Bodies

B-M-2 Valve Body > 4 in. 6 3 50.00% Yes Nominal Pipe Size

B-N-1 Interior of Reactor Vessel 3 2 66.66% No

B-N-2 Integrally Welded Core Support Structures and 2 0 00.00% Yes Interior Attachments to Reactor Vessels

B-N-3 Removable Core Support 1 0 00.00% Yes Structures

B-O Pressure Retaining Welds 3 2 66.66% Yes in Control Rod Housings

Outage 5/EOC-13 McGuire Unit 2 Section 3

Page 2 of 5 Revision 0 December 6, 2000

Page 34: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Class I Inspections (Continued)

Examination Description Inspections Inspections Percentage 6Deferral

Category Required Completed Completed Allowed

B-P Al Pressure Retaining REFERENCE SECTION 11.0 OF THIS REPORT Components

B-Q Steam Generator Tubing See Note below

F-A Class I Component 49 32 65.30% No F01.010 Supports

(Code Case N-491) I

Note: Steam Generator Tubing is examined and documented by the Steam Generator Maintenance Group of the Station Support Division as required by the Station Technical Specifications and is

not included in this report.

6 Deferral of inspection to the end of the interval as allowed by ASME Section XI Tables IWB and IWC

2500-1

Outage 5/EOC-13 McGuire Unit 2 Section 3

Page 3 of 5 Revision 0 December 6, 2000

Page 35: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Class 2 Inspections

Examination Description Inspections Inspections Percentage 6Deferral

Category Required Completed Completed Allowed

C-A Pressure Retaining Welds 25 16 64.00% No

in Pressure Vessels

C-B Pressure Retaining Nozzle 22 12 54.54% No

Welds in Vessels

C-C Integral Attachments for 9 5 55.55% No

Vessels, Piping, Pumps, and Valves

C-D Pressure Retaining Bolting N/A N/A N/A No

Greater Than 2" in Diameter

C-F-1 Pressure Retaining Welds 251 160 63.74% No

in Austenitic Stainless Steel or High Alloy Piping

C-F-2 Pressure Retaining Welds 51 31 60.78% No

in Carbon or Low Alloy Steel Piping

C-G

C-H

F-A

F01.020

Pressure Retaining Welds in Pumps and Valves

All Pressure Retaining Components

Class 2 Component Supports (Code Case N-491)

6 Deferral of inspection to the end of the 2500-1

6 4 66.66%

-J ______________________ a ______________________ .1 ____________________

REFERENCE SECTION 11.0 OF THIS REPORT

-1. I

i , --

181 11664.08% No

interval as allowed by ASME Section Xl Tables IWB and IWC

Outage 5/EOC-13 McGuire Unit 2 Section 3

Page 4 of 5 Revision 0 December 6, 2000

No

Page 36: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Additional Component Support Examinations Class 1, 2 & 3

Examination Description Inspections Inspections Percentage 6Deferral

Category Required Completed Completed Allowed

F-A Supports other than Piping 36 22 61.11% No

F01.040 Supports Class 1, 2 & 3 (Code Case N-491applies)

Examination Description Inspections Inspections Percentage 6DeferTal

Category Required Completed Completed Allowed

F-A Component Supports No

F01.050 Snubbers Class 1, 2 & 3

6 Deferral of inspection to the end of the interval as allowed by ASME Section X1 Tables IWB-2500-1 and

IWC-2500-1.

*Examinations to be performed per Request for Relief 97-005

Augmented Inspections

Description Percentage Complete

Reactor Coolant Pump Flywheels (Item No. Series GO1.) 100% of requirements for OUTAGE 5/EOC-13

Pipe Rupture Protection (Item No. Series G03.) 100% of requirements for OUTAGE 5/EOC-13

Outage 5/EOC-13 McGuire Unit 2 Section 3

Page 5 of 5 Revision 0 December 6, 2000

Page 37: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

4.0 Final Inservice Inspection Plan

The final ISl Plan shown in this section lists all ASME Section Xl Class 1 and Class 2, and Augmented examinations credited for Outage 5/EOC-13 at McGuire Nuclear Station Unit 2.

The information shown below is a field description for the reporting format included in this section of the report:

Item Number

ID Number

Iso / Dwg. Numbers

Proc

Insp Req.

Mat / Sch.

Diam. / Thick

Cal Blocks

Comments

= ASME Section Xl Tables IWB-2500-1 (Class 1), IWC-2500-1 (Class 2), IWF-2500-1 (Class 1 and Class 2 ), Augmented Requirements

= Unique Identification Number

= Location and/or Detail Drawings

- Examination Procedures

= Examination Technique - Magnetic Particle, Dye Penetrant, etc.

= General Description of Material

= Diameter/Thickness

= Calibration Block Number

= General and/or Detail Description

Outage 5fEOC-13 McGuire Unit 2 Section 4

Page 1 of 1 Revision 0 December 6, 2000

Page 38: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

EOC 13

CATEGORY B-G-1, Pressure Retaining Bolting, Greater than 2" In Diameter

tearn Generators

ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS

**** Flange Surface, when connection dissassembled ****

DUKE ENERGY CORPORATION QUALITY ASSURANCE TECHNICAL SERVICES

Inservice Inspection Database Management System

McGuire 2

Inservice Inspection Plan for Interval 2 Outage 5 PROC INSP REQ MAT/SCH DIAITHK CAL BLOCKS

B06.100.001 2SGA-MW-YI-Xl NC MCM 2201.01-0194 QAL-13 VT-1 CS 0.000 2A SIG PRIMARY INLET MANWAY FLANGE.

MCM 2201.01-0126 0.000 YI-X1 QUADRANT. REFERENCE 2MNS-065

Class A

B06.100.002 2SGA-MW-X1-Y2 NC MCM 2201.01-0194 QAL-13 VT-I CS 0.000 2A SIG PRIMARY OUTLET MANWAY FLANGE.

MCM 2201.01-0126 0.000 X1-Y2 QUADRANT. REFERENCE 2MNS-065

Class A

806.100.003 2SGB-MW-YI-X2 NC MCM 2201.01-0194 QAL-13 VT-1 CS 0.000 2B SIG PRIMARY INLET MANWAY FLANGE.

MCM 2201.01-0127 0.000 Y1-X2 QUADRANT. REFERENCE 2MNS-065

Class A

B06.100.004 2SGB-MW-X2-Y2 NC MCM 2201.01-0194 QAL-13 VT-I CS 0.000 2B S/G PRIMARY OUTLET MANWAY FLANGE.

MCM 2201.01-0127 0.000 X2-Y2 QUADRANT. REFERENCE 2MNS-065

Class A

B06.100.005 2SGC-MW-Y1-X1 NC MCM 2201.01-0194 QAL-13 VT-1 CS 0.000 2C S/G PRIMARY INLET MANWAY FLANGE.

MCM 2201.01-0126 0.000 Y1-X1 QUADRANT. REFERENCE 2MNS-065

Class A

806.100.006 2SGC-MW-X1-Y2 NC MCM 2201.01-0194 QAL-13 VT-1 CS 0.000 2C S/G PRIMARY OUTLET MANWAY FLANGE.

MCM 2201.01-0126 0.000 Xl-Y2 QUADRANT. REFERENCE 2MNS-065

Class A

B06.100.007 2SGD-MW-Y1-X2 NC MCM 2201.01-0194 QAL-13 VT-1 CS 0.000 2D S/G PRIMARY INLET MANWAY FLANGE.

MCM 2201.01-0127 0.000 YI-X2 QUADRANT. REFERENCE 2MNS-065

Class A

B06.100.008 2SGD-MW-X2-Y2 NC MCM 2201.01-0194 QAL-13 VT-1 CS 0.000 2D S/G PRIMARY OUTLET MANWAY FLANGE.

MCM 2201.01-0127Class A

Total B06.100 Items:

Total B06 Items:

0.000 X2-Y2 QUADRANT. REFERENCE 2MNS-065

8 8

Plan Report Page 1

1210612000

COMMENTS

Page 39: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

EOC 13

CATEGORY B-G-2, Pressure Retaining Bolting, 2" And Less In Diameter

ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS

DUKE ENERGY CORPORATION QUALITY ASSURANCE TECHNICAL SERVICES

Inservice Inspection Database Management System

McGuire 2

Inservice Inspection Plan for Interval 2 Outage 5 PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

Plan Report Page 2

1210612000

**** Bolts, Studs, and Nuts **** B07.070.003B 2NC-34A NC MCFI-2NC62 QAL-13 VT-1 SS 0.000 3" VALVE. INSPECT ONLY ONE VALVE IN THIS

MC 2553-2.0 0.000 GROUP PER INTERVAL

Class A MCM 1205.09-08

Total B07.070 Items: 1

Total B07 Items: I

Page 40: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

EOC 13

CATEGORY B-J, Pressure Retaining Welds In Piping MNPS 4 or Larger

ITEM NUMBER ID NUMBER SYS ISOIDWG NUMBERS

DUKE ENERGY CORPORATION QUALITY ASSURANCE TECHNICAL SERVICES

Inservice Inspection Database Management System

McGuire 2

Inservice Inspection Plan for Interval 2 Outage 5 PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

**** Circumferential Welds ****

B09.011.010 2NC2FW2-3 NC MCFI-2NC2 NDE-600 UT SS 14.000 50207 PRESSURIZER SURGE LINE SE Circumferential MCM 2201.01-118 160 1.406 UT FROM PIPE SIDE

Class A Term end Pipe to SAFE END

B09.011.010A 2NC2FW2-3 NC MCFI-2NC2 NDE-35 PT SS 14.000 PRESSURIZER SURGE LINE SE Circumferential MCM 2201.01-118 160 1.406

Class A Term end Pipe to SAFE END

B09.011.010B 2NC2FW2-3 NC MCFI-2NC2 NDE-600 UT SS 14.000 50207 PRESSURIZER SURGE LINE SE

Circumferential MCM 2201.01-118 1.640 UT FROM SE SIDE

Class A Term end SAFE END to Pipe SAFE END

B09.011.031 2NC2FW53-24 NC MCFI-2NC53 NDE-600 UT SS 6.000 50211 Circumferential 160 0.719

Class A Stress weld Pipe to Elbow

B09.011.031A 2NC2FW53-24 NC MCFI-2NC53 NDE-35 PT SS 6.000 Circumferential 160 0.719

Class A Stress weld Pipe to Elbow

B09.011.032 2NC2FW53-25 NC MCFI-2NC53 NDE-600 UT SS 6.000 50211 Circumferential 160 0.719

Class A Stress weld Elbow to Flange

B09.011.032A 2NC2FW53-25 NC MCFI-2NC53 NDE-35 PT SS 6.000 Circumferential 160 0.719

Class A Stress weld Elbow to Flange

B09.01 1.034 2NC2FW53-28 NC MCFI-2NC53 NDE-600 UT SS 6.000 50211160Circumferential

Class A Stress weld0.719

Pipe to Elbow

Plan Report Page 3

1210612000

Page 41: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

EOC 13

CATEGORY B-J, Pressure Retaining Welds In Piping

DUKE ENERGY CORPORATION QUALITY ASSURANCE TECHNICAL SERVICES

Inservice Inspection Database Management System

McGuire 2

Inservice Inspection Plan for Interval 2 Outage 5

ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

B09.011.034A 2NC2FW53-28 NC MCFI-2NC53 NDE-35 PT SS 6.000

Circumferential 160 0.719

Class A Stress weld Pipe to Elbow

B09.011.035 2NC2FW53-29 NC MCFI-2NC53 NDE-600 UT SS 6.000 50211

Circumferential 160 0.719

Class A Stress weld Elbow to Pipe

B09.011.035A 2NC2FW53-29 NC MCFI-2NC53 NDE-35 PT SS 6.000 Circumferential 160 0.719

Class A Stress weld Elbow to Pipe

B09.011.036 2NC2FW53-30 NC MCFI-2NC53 NDE-600 UT SS 6.000 50211 Circumferential 160 0.719

Class A Stress weld Pipe to Elbow

B09.011.036A 2NC2FW53-30 NC MCFI-2NC53 NDE-35 PT SS 6.000 Circumferential 160 0.719

Class A Stress weld Pipe to Elbow

B09.011.037 2NC2FW53-31 NC MCFI-2NC53 NDE-600 UT SS 6.000 50211

Circumferential 160 0.719 Class A Stress weld Elbow to

Pipe

B09.011.037A 2NC2FW53-31 NC MCFI-2NC53 NDE-35 PT SS 6.000 Circumferential 160 0.719

Class A Stress weld Elbow to Pipe

B09.011.038 2NC2FW53-36 NC MCFI-2NC53 NDE-600 UT SS 6.000 50211 Circumferential 160 0.719

Class A Stress weld Pipe to Elbow

B09.011.038A 2NC2FW53-36 NC MCFI-2NC53 NDE-35 PT SS 6.000160Circumferential

Class A Stress weld

0.719

Pipe to Elbow

Plan Report Page 4

1210612000

Page 42: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

EOC 13

CATEGORY B-J, Pressure Retaining Welds In Piping

MNP 4 or Langer

DUKE ENERGY CORPORATION QUALITY ASSURANCE TECHNICAL SERVICES

Inservice Inspection Database Management System

McGuire 2

Inservice Inspection Plan for Interval 2 Outage 5

Circumferential Class A

160 Valve 2N1181 to Elbow

0.719

Plan Report Page 5

12/0612000

ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

B09.011.039 2NC2FW53-37 NC MCFI-2NC53 NDE-600 UT SS 6.000 50211

Circumferential 160 0.719

Class A Stress weld Elbow to Flange

B09.011.039A 2NC2FW53-37 NC MCFI-2NC53 NDE-35 PT SS 6.000

Circumferential 160 0.719

Class A Stress weld Elbow to Flange

B09.011.162 2N12F471 NI MCFI-2NI15 NDE-600 UT SS 6.000 50211

Circumferential 160 0.719

Class A Valve 2N1180 to Elbow

B09.011.162A 2NI2F471 NI MCFI-2NI15 NDE-35 PT SS 6.000

Circumferential 160 0.719

Class A Valve 2N1180 to Elbow

B09.011.163 2N12F474 NI MCFI-2NI15 NDE-600 UT SS 6.000 50211

Circumferential 160 0.719

Class A Pipe to Elbow

B09.011.163A 2NI2F474 NI MCFI-2NI15 NDE-35 PT SS 6.000

Circumferential 160 0.719

Class A Pipe to Elbow

B09.011.164 2N12F477 NI MCFI-2NI15 NDE-600 UT SS 6.000 50211

Circumferential 160 0.719

Class A Pipe to Elbow

B09.011.164A 2NI2F477 NI MCFI-2NI15 NDE-35 PT SS 6.000

Circumferential 160 0.719

Class A Pipe to Elbow

B09.011.165 2NI2F494 NI MCFI-2NI16 NDE-600 UT SS 6.000 50211

Page 43: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

EOC 13

CATEGORY B-J. Pressure Retaining Welds In PipingP MN 4 r Larger

DUKE ENERGY CORPORATION QUALITY ASSURANCE TECHNICAL SERVICES

Inservice Inspection Database Management System

McGuire 2

Inservice Inspection Plan for Interval 2 Outage 5

ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

B09.011.165A 2N12F494 NI MCFI-2NI16 NDE-35 PT SS 6.000

Circumferential 160 0.719

Class A Valve 2NI181 to Elbow

B09.011.166 2NI2F496 NI MCFI-2NI16 NDE-600 UT SS 6.000 50211

Circumferential 160 0.719

Class A Elbow to Pipe

B09.011.166A 2Nl2F496 NI MCFI-2NI16 NDE-35 PT SS 6.000

Circumferential 160 0.719

Class A Elbow to Pipe

B09.011.167 2Nl2F866 NI MCFI-2NI16 NDE-600 UT SS 6.000 50211

Circumferential 160 0.719

Class A Pipe to Elbow

B09.011.167A 2N12F866 NI MCFI-2NI16 NDE-35 PT SS 6.000

Circumferential 160 0.719

Class A Pipe to Elbow

Total B09.011 Items: 31

Plan Report Page 6

12/06/2000

Page 44: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

EOC 13

CATEGORY B-J, Pressure Retaining Welds In

Piping 2ocket Welds

ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS

DUKE ENERGY CORPORATION QUALITY ASSURANCE TECHNICAL SERVICES

Inservice Inspection Database Management System

McGuire 2

Inservice Inspection Plan for Interval 2 Outage 5PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

B09.040.006 2NC2FW40-1 NC MCFI-2NC40 NDE-35 PT SS 2.000

Socket 160 0.344

Class A Stress weld Nozzle to Pipe

B09.040.017 2NC2FW40-12 NC MCFI-2NC40 NDE-35 PT SS 1.500

Socket 160 0.281

Class A Stress weld Full Coupling to Pipe

B09.040.018 2NC2FW40-14 NC MCFI-2NC40 NDE-35 PT SS 1.500

Socket 160 0.281

Class A Stress weld Valve 2N117 to Pipe

B09.040.050 2NI2FW89-1 NI MCFI-2N189 NDE-35 PT SS 1.500

Socket 160 0.281

Class A Stress weld Valve 2NI349 to Pipe

B09.040.051 2NI2FW89-3 NI MCFI-2NI89 NDE-35 PT SS 1.500

Socket 160 0.281

Class A Stress weld Valve 2NI348 to Pipe

B09.040.052 2NI2FW89-4 NI MCFI-2NI89 NDE-35 PT SS 1.500

Socket 160 0,281

Class A Stress weld Pipe to Valve 2NI19

B09,040.053 2NI2FW89-5 NI MCFI-2NI89 NDE-35 PT SS 1.500

Socket 160 0.281

Class A Stress weld Valve 2NI354 to Pipe

B09.040.054 2NI2FW89-6 NI MCFI-2NI89 NDE-35 PT SS 1.500

Socket

Class A Stress weld

160 Pipe to Valve 2NI15

0.281

Plan Report Page 7

12106/2000

r

Page 45: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

EOC 13

CATEGORY B-J, Pressure Retaining Welds In Piping e

f2ockt Welds

DUKE ENERGY CORPORATION QUALITY ASSURANCE TECHNICAL SERVICES

Inservice Inspection Database Management System

McGuire 2

Inservice Inspection Plan for Interval 2 Outage 5

ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMEN I

B09.040.055 2NI2FW89-7 NI MCFI-2NI89 NDE-35 PT SS 1.500

Socket 160 0.281

Class A Stress weld Valve 2NI347 to Pipe

B09.040.056 2NI2FW89-8 NI MCFI-2NI89 NDE-35 PT SS 1.500

Socket 160 0.281

Class A Stress weld Pipe to Valve 2NI17

Total B09.040 Items:

Total B09 Items:

10 41

Plan Report Page 8

12106/2000

Page 46: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

EOC 13

CATEGORY C-A! Pressure Retaining Welds In Pressure Vessels Eiubesheet-to-Shell Weld

ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS

DUKE ENERGY CORPORATION QUALITY ASSURANCE TECHNICAL SERVICES

Inservice Inspection Database Management System

McGuire 2

Inservice Inspection Plan for Interval 2 Outage 5 PROC INSP REQ MAT/SCH DIANTHK CAL BLOCKS COMMENTS

Plan Report Page 9

12/0612000

C01.030.011 2BCSHX-50-B NS MCM 1201.06-0093 NDE-630 UT SS 55.375 50420 2B CONTAINMENT SPRAY HEAT EXCH. SHELL Circumferential MC 2563.1-0 0.437 TO BOTTOM TUBE SHEET PSI EXAMINATION

Class B SHELL(2B) to LISTED ID# AS NS COOLER 2B-120

TUBESHEET

C01.030.012 2BCSHX-50-A NS MCM 1201.06-0093 NDE-630 UT SS 55.375 50420 2B CONTAINMENT SPRAY HEAT EXCH. SHELL

Circumferential MC 2563.1-0 0.437 TO TOP TUBE SHEET PSI EXAMINATION LISTED

Class B SHELL(2B) to ID# AS NS COOLER 2B3-125

TUBESHEET

Total C01.030 Items: 2Total C01 Items: 2

Page 47: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

EOC 13

CATEGORY C-B, Pressure Retaining Nozzle Welds In Vessels

Nzz._les Without Reinforcing Plate In Vessels > W112 in. Nom. ThicknessITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS

DUKE ENERGY CORPORATION QUALITY ASSURANCE TECHNICAL SERVICES

Inservice Inspection Database Management System

McGuire 2

Inservice Inspection Plan for Interval 2 Outage 5 PROC INSP REQ MAT/SCH DIAITHK CAL BLOCKS COMMENTS

**** Nozzle-to-Shell (or Head) Weld **** C02.021.007 2SGC-W259 SM M

Circumferential M Class B

1CM 2201.01-0207

1CM 2201.01-0160

NDE-620 UT CS

See Com Nozzle to SHELL

6.000 5139385 STEAM GENERATOR 2C AUXILLIARY

4.125 50236A FEEDWATER NOZZLE TO SHELL. REFERENCE 2MNS-068 ADDED AS A RESULT OF S/G REPLACEMENT. Depending upon the examiner's qualifications, procedure PDI-UT-6 may be used in lieu of procedure NDE-620

C02.021.007A 2SGC-W259

Circumferential Class B

SM MCM 2201.01-0207

MCM 2201.01-0160NDE-25 MT CS 6.000

4.125

Nozzle to SHELL

STEAM GENERATOR 2C AUXILLIARY FEEDWATER NOZZLE TO SHELL. REFERENCE 2MNS-068 ADDED AS A RESULT OF S/G REPLACEMENT.

Total C02.021 Items: 2

Total C02 Items: 2

Plan Report Page 10

1210612000

Page 48: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

EOC 13

CATEGORY C-C, Integral Attachments For Vessels, Piping, Pumps. And Valves

ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS

DUKE ENERGY CORPORATION QUALITY ASSURANCE TECHNICAL SERVICES

Inservice Inspection Database Management System

McGuire 2

Inservice Inspection-Plan for Interval 2 Outage 5

PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

**** Integrally Welded Attachments **** C03.020.010 2MCA-ND-6123 ND MCFI-2ND18

2MCA-Nr)-6123

Class B

NDE-35 PT SS-CS- *1fflfl A A*.-r* flt IRArLET

I �3I¶ML P� I I IW�flIVI�IN Iu.UUU 1.000

I I

Total C03.020 Items:

Total C03 Items:

Plan Report Page 11

1210612000

IN I M-UMA/L M I I/%.,MIVII-IN I

Page 49: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

EOC 13

CATEGORY C-F-I, Pressure Retaining Welds In Austenitic SS or High Alloy Piping EPloInc Welds >= 318 in. Nominal Wall ThicknessITNor Piping > NPS 4 ITEM NUMBER ID NUMBER SYS ISOIDWG NUMBERS

DUKE ENERGY CORPORATION QUALITY ASSURANCE TECHNICAL SERVICES

Inservice Inspection Database Management System

McGuire 2

Inservice Inspection Plan for Interval 2 Outage 5PROC INSP REQ MAT/SCH DIAITHK CAL BLOCKS COMMENTS

**** Circumferential Weld C05.01 1.021 2NDP109-1

Circumferential Class B

ND MCFI-2ND10 NDE-600 UT SS STD

Elbow to Pipe

C05.011.021A 2NDP109-1 ND MCFI-2ND10 NDE-35 PT SS 12.000

Circumferential STD 0.375

Class B Elbow to Pipe

C05.011.030 2ND2F-202 ND MCFI-2ND10 NDE-600 UT SS 12.000 *See Section 8 for Calibration Block Requirements

Circumferential STD 0.375

Class B Pipe to Elbow

C05.011.030A 2ND2F-202 ND MCFI-2ND10 NDE-35 PT SS 12.000

Circumferential STD 0.375

Class B Pipe to Elbow

C05.011.034 2ND2FW16-18 ND MCFI-2ND16 NDE-600 UT SS 12.000 50313

Circumferential STD 0.375

Class B Elbow to Pipe

C05.011.034A 2ND2FW16-18 ND MCFI-2ND16 NDE-35 PT SS 12.000

Circumferential STD 0.375

Class B Elbow to Pipe

C05.011.104 2N12F440 NI MCFI-2NI14 NDE-600 UT SS 6.000 50211

Circumferential 160 0.719

Class B Reducer to Pipe

C05.011.104A 2N12F440 NI MCFI-2NI14 NDE-35 PT SS 6.000Circumferential

Class B

160 Reducer to Pipe

0.719

Plan Report Page 12

1210612000

12.000 0.375

50313

SYS ISO/DWG NUMBERS

Page 50: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

EOC 13

CATEGORY C-F-t, Pressure Retaining Welds In Austenitic SS or High Alloy Piping Wiping Welds >= 318 in. Nominal Wall Thickness

DUKE ENERGY CORPORATION QUALITY ASSURANCE TECHNICAL SERVICES

Inservice Inspection Database Management System

McGuire 2Plan Report

Page 13 .4 'lnlI*Jnnn

Wor Piping > NPS 4 Inservice Inspection Plan for Interval 2 Outage 5 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIAITHK CAL BLOCKS COMMENTS

C05.011.126 2NIP145-1 NI MCFI-2NI16 NDE-600 UT SS 6.000 50211 Circumferential 160 0.719

Class B Elbow to Pipe

C05.011.126A 2NIP145-1 NI MCFI-2NI16 NDE-35 PT SS 6.000 Circumferential 160 0.719

Class B Elbow to Pipe

C05.011.129 2NI2F493 NI MCFI-2NI16 NDE-600 UT SS 6.000 50211 Circumferential 160 0.719

Class B Pipe to Valve 2NI181

C05.011.129A 2NI2F493 NI MCFI-2NI16 NDE-35 PT SS 6.000 Circumferential 160 0.719

Class B Pipe to Valve 2NI181

C05.011.151 2NI2FW26-4 NI MCFI-2NI26 NDE-600 UT SS 12.000 50219 Circumferential 140 1.125

Class B Tee to Reducer

C05.011.151A 2NI2FW26-4 NI MCFI-2NI26 NDE-35 PT SS 12.000

Circumferential 140 1.125 Class B Tee to

Reducer

C05.011.152 2NI2FW26-10 NI MCFI-2NI26 NDE-600 UT SS 12.000 50219 Circumferential 140 1.125

Class B Tee to Reducer

C05.011.152A 2NI2FW26-10 NI MCFI-2NI26 NDE-35 PT SS 12.000 Circumferential 140 1.125

Class B Tee to Reducer

C05.011.159 2N12F449 NI MCFI-2NI14 NDE-600 UT SS 6.000 *See Section 8 for Calibration Block Requirements

CircumferentialClass B

160 0.719Pipe to Elbow

Page 51: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

EOC 13

CATEGORY C-F-1, Pressure Retaining Welds In Austenitic SS or High Alloy Piping Wiping Welds >= 318 in. Nominal Wall Thickness

DUKE ENERGY CORPORATION QUALITY ASSURANCE TECHNICAL SERVICES

Inservice Inspection Database Management System

McGuire 2

Wor Piping > NPS 4 Inservice Inspection Plan for Interval 2 Outage 5 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

C05.011.159A 2N12F449 NI MCFI-2NI14 NDE-35 PT SS 6.000 Circumferential 160 0.719

Class B Pipe to Elbow

C05.0i1.163 2N12F443 NI MCFI-2NI14 NDE-600 UT SS 6.000 Circumferential 160 0.719

Class B Pipe to Elbow

C05.011.163A 2N12F443 NI MCFI-2NI14 NDE-35 PT SS 6.000 Circumferential 160 0.719

Class B Pipe to Elbow

C05.011.164 2N12F590 NI MCFI-2NI20 NDE-600 UT SS 12.000 Circumferential 140 1.125

Class B Elbow to Tee

C05.011.164A 2NI2F590 NI MCFI-2NI20 NDE-35 PT SS 12.000 Circumferential 140 1.125

Class B Elbow to Tee

C05.011.165 2NI2F591 NI MCFI-2NI20 NDE-600 UT SS 12.000

Circumferential 140 1.125

Class B Tee to Pipe

C05.011.165A 2N12F591 NI MCFI-2NI20 NDE-35 PT SS 12.000

Circumferential 140 1.125

Class B Tee to Pipe

Total C05.011 Items: 24

Plan Report Page 14

S'fidflti'lnnn

Page 52: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

EOC 13

CATEGORY C-F-I, Pressure Retaining Welds In Austenitic SS or High Alloy Piping WPiping Welds > 115 in. Nom Wall For Piping >=

"*NPS 2 And <= NPS 4 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS

DUKE ENERGY CORPORATION QUALITY ASSURANCE TECHNICAL SERVICES

Inservice Inspection Database Management System

McGuire 2

Inservice Inspection Plan for Interval 2 Outage 5PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

**** Circumferential Weld ****

C05.021.008 2NI2F535 Circumferential

Class B

NI MCFI-2NI17 4.000 0.531

NDE-600 UT SS 160

Tee to Reducer

C05.021.008A 2N12F535 NI MCFI-2NI17 NDE-35 PT SS 4.000 Circumferential 160 0.531

Class B Tee to Reducer

C05.021.017 2N12F-693 NI MCFI-2NI2 NDE-600 UT SS 4.000 50436

Circumferential 80 0.337

Class B Reducer to Elbow

C05.021.017A 2N12F-693 NI MCFI-2NI2 NDE-35 PT SS 4.000

Circumferential 80 0.337

Class B Reducer to Elbow

C05.021.063 2NV2FW116-2 NV MCFI-2NV116 NDE-600 UT SS 3.000 50225

Circumferential 160 0.438

Class B Elbow to Pipe

C05.021.063A 2NV2FW116-2 NV MCFI-2NV116 NDE-35 PT SS 3.000 Circumferential 160 0.438

Class B Elbow to Pipe

C05.021.072 2NV2FW292-3 NV MCFI-2NV292 NDE-600 UT SS 3.000 50225 Circumferential 160 0.438

Class B Elbow to Elbow

C05.021.072A 2NV2FW292-3 NV MCFI-2NV292 NDE-35 PT SS 3.000Circumferential

Class B

160 Elbow to Elbow

0.438

Plan Report Page 15

1210612000

50275

Page 53: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

EOC 13

CATEGORY C-F-I, Pressure Retaining Welds In Austenitic SS or High Alloy Piping *PiDinq Welds > 1/5 in. Nom Wall For PiDina >=MNPS 2 And <= NPS 4

DUKE ENERGY CORPORATION QUALITY ASSURANCE TECHNICAL SERVICES

Inservice Inspection Database Management System

McGuire 2

Inservice Inspection Plan for Interval 2 Outage 5ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

C05.021.081 2RCPA-TE NV MCFI-2NV69 NDE-600 UT SS 3.000 50225 FOR DWG. ON RECIPROCATING CHARGING

Circumferential 160 0.438 PUMP ACCUMULATOR SEE MCM 1201.04-0197

Class B Term end Tee to RCHP ACCUMULATOR

C05.021.081A 2RCPA-TE NV MCFI-2NV69 NDE-35 PT SS 3.000 FOR DWG. ON RECIPROCATING CHARGING

Circumferential 160 0.438 PUMP ACCUMULATOR SEE MCM 1201.04-0197

Class B Term end Tee to RCHP ACCUMULATOR

C05.021.087 2NV2FW33-23 NV MCFI-2NV33 NDE-600 UT SS 4.000

Circumferential 40 0.237

Class B Pipe to Elbow

C05.021.087A 2NV2FW33-23 NV MCFI-2NV33 NDE-35 PT SS 4.000

Circumferential 40 0.237

Class B Pipe to Elbow

C05.021.090 2NV2FW101-1 NV MCFI-2NV101 NDE-600 UT SS 4.000 50275 Circumferential 160 0.531

Class B Pipe to Reducer

C05.021.090A 2NV2FW101-1 NV MCFI-2NV101 NDE-35 PT SS 4.000

Circumferential 160 0.531 Class B Pipe to

Reducer

C05.021.099 2NV2FW54-16 NV MCFI-2NV54 NDE-600 UT SS 4.000 50275

Circumferential 160 0.531 Class B Reducer to

Elbow

C05.021.099A 2NV2FW54-16 NV MCFI-2NV54 NDE-35 PT SS 4.000

Circumferential 160 0.531 Class B Reducer to

Elbow

Total C05.021 Items: 16

Plan Report Page 16

1210612000

Page 54: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

EOC 13

CATEGORY C-F-I, Pressure Retaining Welds In Austenitic SS or High Alloy Piping

Socket Welds

ITEM NUMBER ID NUMBER SYS ISO/DW(• NUMBERS

DUKE ENERGY CORPORATION QUALITY ASSURANCE TECHNICAL SERVICES

Inservice Inspection Database Management System

McGuire 2

Inservice Inspection Plan for Interval 2 Outage 5PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

C05.030.008 2N12FW33-9

Socket Class B

NI MCFI-2NI33 NDE-35 PT SS 160

Pipe to Full Coupling

C05.030.052 2NV2FW101-7 NV MCFI-2NV101 NDE-35 PT SS 2.000

Socket 160 0.344

Class B Pipe to Tee

C05.030.061 2NVP182-1 NV MCFI-2NV180 NDE-35 PT SS 2.000

Socket 160 0.344

Class B Pipe to Flange

C05.030.070 2NV2FW235-4 NV MCFI-2NV235 NDE-35 PT SS 2.000

Socket 160 0.344

Class B Elbow to Pipe

C05.030.079 2NV2FW303-15 NV MCFI-2NV303 NDE-35 PT SS 2.000

Socket 160 0.344

Class B Tee to Pipe

Total 005.030 Items: 5

Plan Report Page 17

1210612000

2.000 0.344

Page 55: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

EOC 13

CATEGORY C-F-2. Pressure Retaining Welds In Carbon Or Low Alloy Steel PipingWiping Welds >= 318 in. Nominal Wall ThicknessITor PipingN > NPS 4 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS

DUKE ENERGY CORPORATION QUALITY ASSURANCE TECHNICAL SERVICES

Inservice Inspection Database Management System

McGuire 2

Inservice Inspection Plan for Interval 2 Outage 5 PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

**** Circumferential Weld ****

C05.051.002 2CA2FW45-27 CA MCFI-2CA45 NDE-600 UT CS 6.000 50331

Circumferential 80 0.432

Class B Valve 2CF128B to Pipe

C05.051.002A 2CA2FW45-27 CA MCFI-2CA45 NDE-25 MT CS 6.000

Circumferential 80 0.432

Class B Valve 2CF128B to Pipe

C05.051.003 2CA2FW45-21 CA MCFI-2CA45 NDE-600 UT CS 6.000 50331

Circumferential 80 0.432

Class B Tee to Elbow

C05,051.003A 2CA2FW45-21 CA MCFI-2CA45 NDE-25 MT CS 6.000

Circumferential 80 0.432

Class B Tee to Elbow

C05.051.011 2CA2FW51-25 CA MCFI-2CA51 NDE-600 UT CS 6.000 50281

Circumferential 160 0.719

Class B Term end Elbow to Nozzle SG-2C

C05.051.011A 2CA2FW51-25 CA MCFI-2CA51 NDE-25 MT CS 6.000

Circumferential 160 0.719

Class B Term end Elbow to Nozzle SG-2C

C05.051.204 2SM5C-D SM MCFI-2SM13 NDE-600 UT CS 10.000 50249

Circumferential Class B

1.500 Nozzle Forged nozzle to Transition piece

C05.051.204A 2SM5C-D

Circumferential Class B

SM MCFI-2SM13 NDE-25 MT CS

Nozzle Forged nozzle to Transition piece

Plan Report Page 18

12/0612000

10.000 1.500

Page 56: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

EOC 13

CATEGORY C-F-2, Pressure Retainina Welds In Carbon Or Low Alloy Steel Piping Wping Welds >= 3/8 in. Nominal Wall Thickness

DUKE ENERGY CORPORATION QUALITY ASSURANCE TECHNICAL SERVICES

Inservice Inspection Database Management System

McGuire 2Plan Report

Page 19 4 lfnl~ngnn

Ufor Piping > NPS 4 Inservice Inspection Plan for Interval 2 Outage 5 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

C05.051.209 2SM2F-22 SM MCFI-2SM50 NDE-12 RT CS 32.000

Circumferential MCFD 2591-01.01 1.375

Class B Transition Ring to Elbow

C05.051.209A 2SM2F-22 SM MCFI-2SM50 NDE-25 MT CS 32.000

Circumferential MCFD 2591-01.01 1.375

Class B Transition Ring to Elbow

C05.051.215 2SM2F-72 SM MCFI-2SM3 NDE-600 UT CS 34.000 40415

Circumferential MCFD 2593-01.03 1.250

Class B Elbow to Pipe

C05.051.215A 2SM2F-72 SM MCFI-2SM3 NDE-25 MT CS 34.000

Circumferential MCFD 2593-01.03 1.250

Class B Elbow to Pipe

C05.051.217 2SM2FW13-10 SM MCFI-2SM13 NDE-600 UT CS 36.000 50385

Circumferential 2.437

Class B Pipe to Valve 2SM3AB

C05.051.217A 2SM2FW13-10 SM MCFI-2SM13 NDE-25 MT CS 36.000

Circumferential 2.437

Class B Pipe to Valve 2SM3AB

C05.051.220 2SGA-W1 38 SM MCFI-2SM50 NDE-600 UT CS 32.625 Steam Generator 2A

Circumferential MCFD-2591-01.01 1.500 Main Ssteam Nozzle to

Class B Term end MCM 2201.01-0207 2S/G-A Nozzle to Transition Ring

Transition Ring Transition Ring added as a result of SGRP *Reference General Requirements Section 8.1.10

C05.051.220A 2SGA-W138 SM MCFI-2SM50 NDE-25 MT CS 32.625 Steam Generator 2A

Circumferential Class B Term end

MCFD-2591-01.01 MCM 2201.01-0207

1.500

2S/G-A to Transition Ring

Main Ssteam Nozzle to Transition Ring Transition Ring added as a result of SGRP

Page 57: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

EOC 13

CATEGORY C-F-2. Pressure Retaining Welds In Carbon Or Low Alloy Steel Piping *Pi•Jin-q Welds >= 318 in. Nominal Wall Thickness

DUKE ENERGY CORPORATION QUALITY ASSURANCE TECHNICAL SERVICES

Inservice Inspection Database Management System

McGuire 2Plan Report

Page 20 4 •l5 llal~inn

*or Piping> NPS 4 Inservice Inspection Plan for Interval 2 Outage 5 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

C05.051.252 2SV2FW9-7 SV MCFI-2SV9 NDE-600 UT CS 6.000 50281

Circumferential XXS 0.864

Class B Pipe to Valve 2SV19

C05.051.252A 2SV2FW9-7 SV MCFI-2SV9 NDE-25 MT CS 6.000 Circumferential XXS 0.864

Class B Pipe to Valve 2SVI 9

C05.051.300 2VP2FW1-4 VP MCFI-2VP1 NDE-600 UT CS 12.000 50440

Circumferential STD 0.375

Class B Flange to Pipe

C05.051.300A 2VP2FWI-4 VP MCFI-2VP1 NDE-25 MT CS 12.000 Circumferential STD 0.375

Class B Flange to Pipe

C05.051.301 2VP2FW2-1 VP MCFI-2VP2 NDE-600 UT CS 24.000 * REFERENCE 8.1.10 OF GENERAL

Circumferential STD 0.375 REQUIREMENTS

Class B Flange to Pipe

C05.051.301A 2VP2FW2-1 VP MCFI-2VP2 NDE-25 MT CS 24.000

Circumferential STD 0.375

Class B Flange to Pipe

Total C05.051 Items:

Total C05 Items:

22

67

Page 58: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

EOC 13

CATEGORY D-B, Systems In Support Of ECC, CHR, Atmos. Cleanup, And Reactor RHR E Integral Attachment

ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS

DUKE ENERGY CORPORATION QUALITY ASSURANCE TECHNICAL SERVICES

Inservice Inspection Database Management System

McGuire 2

Inservice Inspection Plan for Interval 2 Outage 5 PROC INSP REQ MAT/SCH DIAITHK CAL BLOCKS COMMENTS

**** Component Supports and Restraints **** D02.020.040 2MCA-RN-3083 RN 2RN-351 QAL-14 VT-3 NA 0.000 RIGID RESTRAINT

Rigid Restraint (SHT.20F3) 0.594 PIPE ATT.

Class C

D02.020.041 2MCA-RN-3086 RN 2RN-351 QAL-14 VT-3 NA 0.000 RIGID SUPPORT Rigid Support (SHT.20F3) 0.375 PIPE ATT.

Class C

Total D02.020 Items: 2

Plan Report Page 21

1210612000

Total D02 Items: 2

Page 59: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

EOC 13

CATEGORY F-A, Supports

MClass 1 Pipn upot

ITEM NUMBER ID NUMBER

F01.010.102A 2MCR-NV-4443 Rigid Support

Class A

(Categiory A)

SYS ISO/DWG NUMBERS

NV 2NV-204(SHT.1OF3)

DUKE ENERGY CORPORATION QUALITY ASSURANCE TECHNICAL SERVICES

Inservice Inspection Database Management System

McGuire 2

Inservice Inspection Plan for Interval 2 Outage 5 PROC INSP REQ MAT/SCH DIANTHK CAL BLOCKS COMMENTS

QAL-14 VT-3 NA 2.000 0.000

F01.010.103A 2MCR-NV-4438 NV 2NV-204(SHT.1OF3) QAL-14 VT-3 NA 3.000

Rigid Support 0.000

Class A

Total F01.010 Items: 2

Plan Report Page 22

12/0612000

Page 60: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

EOC 13

CATEGORY F-A, Supports (Categorv A)

MClass 2 PiNUMBE Su

ITEM NUMBER ID NUME3ER SYS ISO/DWG NUMBERS

DUKE ENERGY CORPORATION QUALITY ASSURANCE TECHNICAL SERVICES

Inservice Inspection Database Management System

McGuire 2

Inservice Inspection Plan for Interval 2 Outage 5 PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

F01.020.078B 2MCA-FW-5009 FW 2FW-350 SHT.1 QAL-14 VT-3 NA 0.000

Mech Snubber 0.000

Class B

F01.020.079C 2MCA-FW-5160 FW 2FW-350 SHT.2 QAL-14 VT-3 NA 0.000

Spring Hgr 0.000

Class B

F01.020.080C 2MCA-FW-5180 FW 2FW-350 SHT.2 QAL-14 VT-3 NA 0.000

Hyd Snubber 0.000

Class B

F01.020.108B 2MCA-ND-6108 ND 2ND-350(SHT.10F7) QAL-14 VT-3 NA 8.000

Rigid Restraint 0.000

Class B

F01.020.122B 2MCA-ND-6117 ND 2ND-350(SHT.7OF7) QAL-14 VT-3 NA 8.000

Rigid Restraint 0.000

Class B

F01.020.224B 2MCA-NS-5305 NS 2NS-352(SHT.10F2) QAL-14 VT-3 NA 10.000

Rigid Restraint 0.000

Class B

F01.020.225B 2MCA-NS-5308 NS 2NS-352(SHT.2OF2) QAL-14 VT-3 NA 8.000

Rigid Restraint 0.000

Class B

F01.020.250A 2-MCA-S-NI-504-I-K NV 2-MCA-S-NI-504-I-RD7 QAL-14 VT-3 NA 2.000

Rigid Restraint Class B

0.000

Plan Report Page 23

12106/2000

Page 61: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

EOC 13

CATEGORY F-A. SuDiorts (Cateqory A)DUKE ENERGY CORPORATION

QUALITY ASSURANCE TECHNICAL SERVICES Inservice Inspection Database Management System

MClass 2 pi McGuire 2 Page 24 E Inservice Inspection Plan for Interval 2 Outage 5 12/0612000

ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

F01.020.251C 2-MCA-S-NI-504-I-L NV 2-MCA-S-NI-504-I-RD7 QAL-14 VT-3 NA 2.000

Mech Snubber 0.000 Class B

F01.020.264A 2MCR-NV-5191 NV 2NV-201(SHT.2OF2) QAL-14 VT-3 NA 2.000 Rigid Support 0.000

Class B

Total F01.020 Items: 10

Plan Report

Page 62: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

EOC 13

CATEGORY F-A. SuDDorts

Class 3 Piping Supports

ITEM NUMBER ID NUME

(Category A)

EER SYS ISO/DWG NUMBERS

DUKE ENERGY CORPORATION QUALITY ASSURANCE TECHNICAL SERVICES

Inservice Inspection Database Management System

McGuire 2

Inservice Inspection Plan for Interval 2 Outage 5 PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

F01.030.154B 2MCA-RN-3028 RN 2RN-351(SHT.1OF3) QAL-14 VT-3 NA 20.000

Rigid Restraint 0.000

Class C

F01.030.155B 2MCA-RN-3083 RN 2RN-351(SHT.2OF3) QAL-14 VT-3 NA 18.000

Rigid Restraint 0.000

Class C

F01.030.156A 2MCA-RN-3086 RN 2RN-351(SHT.2OF3) QAL-14 VT-3 NA 18.000

Rigid Restraint 0.000

Class C

F01.030.157B 2MCA-RN-3045 RN 2RN-351(SHT.3OF3) QAL-14 VT-3 NA 18.000

Rigid Restraint 0.000

Class C

Total F01.030 Items: 4

Plan Report Page 25

1210612000

Page 63: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

EOC 13

CATEGORY F-A, Supports

mSupports other than Piping SupDorts (Class 1. 2.

IT~FhA NIl IRA~tE lfl Nil I!�AP�P � I�C�IflWC NUMRFRS

DUKE ENERGY CORPORATION QUALITY ASSURANCE TECHNICAL SERVICES

Inservice Inspection Database Management System

McGuire 2

Inservice Inspection Plan for Interval 2 Outage 5

PROC INSP REQ MAT/SCH DIAITHK CAL BLOCKS COMMENTS

F01.040.005 2RCP-B-SUPPORT NC MC 1070-7

Class A

F01.040.023 2RNP-SUP-2B RN

OAL-14 VTI-3N/�L u.uuiJ

MC 1070-8 MC 1070-17

QAL-14 VT-3 NAMC1201.05-190

U.UUU 0.000

u.uuu0.000 0.000

2B RCP SUPPORT COLUMN ASSEMBLIES AND LATERAL SUPPORT HANGER FUNCTION CATEGORIZATION B

2B NUCLEAR SERVICE WATER PUMP SUPPORT HANGER FUNCTION CATEGORIZATION B

Class C

Total F01.040 Items:

Plan Report Page 26

1210612000

Total F01 Items:

2

18

In KIHhA9Zr:P SYS ISO/DWG NUMBERS

NA

Page 64: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

5.0 Results Of Inspections Performed

The results of each examination shown in the final ISl Plan (Section 4 of this report) are included in this section. The completion date and status for each examination are shown. Limited examinations are described in further detail in Section 5.2. All examinations revealing reportable indications are described in further detail in Section 6.

5.1 The information shown below is a field description for the reporting format included in this section of the report:

Item Number

ID Number

Insp Date

Insp Status

Insp Limited

Geo. Ref. (Geometric Reflector applies only to UT)

Comments

= ASME Section XI Tables IWB-2500-1 (Class 1), IWC-2500-1 (Class 2), IWF2500-1 (Class I and Class 2), Augmented Requirements

= Unique Identification Number

= Date of Examination

= CLR Clear REC Recordable REP Reportable

= Indicates inspection was limited. Coverage obtained is listed

= �Y Yes N No

= General and/or Detail Description

Outage 5/EOC-13 McGuire Unit 2 Section 5

Page 1 of 2 Revision 0 December 6, 2000

Page 65: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

EOC 13

Plant: McGuire 2

ITEM NUMBER

B06.100.001

B06.100.002

B06.100.003

B06.100.004

B06.100.005

B06.100.006

B06.100.007

B06.100.008

B07.070.0038

B09.01 1.010

B09.011.01 OA

B09.01 1.010B

B09.011.031

B09.011.031A

B09.011.032

B09.011.032A

B09.011.034

B09.011.034A

B09.011.035

B09.011.035A

B09.011.036

B09.011.036A

B09.011.037

B09.011.037A

B09.011.038

B09.011.038A

B09.011.039

B09.011.039A

B09.011.162

B09.011.162A

B09.011.163

B09.011.163A

B09.011.164

B09.011.164A

B09.011.165

B09.011.165A

809.011.166

Run D Page 1

12/0612000

ID NUMBER 2SGA-MW-YI-Xl

2SGA-MW-X1-Y2

2SGB-MW-YI-X2

2SGB-MW-X2-Y2

2SGC-MW-YI-Xl

2SGC-MW-XI-Y2

2SGD-MW-YI-X2

2SGD-MW-X2-Y2

2NC-34A

2NC2FW2-3

2NC2FW2-3

2NC2FW2-3

2NC2FW53-24

2NC2FW53-24

2NC2FW53-25

2NC2FW53-25

2NC2FW53-28

2NC2FW53-28

2NC2FW53-29

2NC2FW53-29

2NC2FW53-30

2NC2FW53-30

2NC2FW53-31

2NC2FW53-31

2NC2FW53-36

2NC2FW53-36

2NC2FW53-37

2NC2FW53-37

2N12F471

2N12F471

2N12F474

2N12F474

2N12F477

2N12F477

2N12F494

2NI2F494

2N12F496

DUKE ENER(% JRPORATION QUALITY ASSURANCE TECHNICAL SERVICES

In-Service Inspection Database Management System McGuire 2 Inservice Inspection Listing

Interval 2 Outage 5

SYSTEM INSP DATE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS

NC 09/21/2000 CLR -- N N

NC 09/21/2000 CLR --- N N

NC 09/20/2000 CLR -- N N

NC 09/20/2000 CLR --- N N

NC 09/25/2000 CLR --- N N

NC 09/25/2000 CLR -- N N

NC 09/22/2000 CLR --- N N

NC 09/22/2000 CLR --- N N

NC 09/28/2000 CLR --- N N

NC 09/21/2000 CLR --- N N

NC 09/21/2000 CLR --- N N

NC 09/21/2000 CLR --- N N

NC 09/20/2000 CLR --- N N

NC 09/20/2000 CLR -- N N

NC 09/20/2000 CLR 60.30% N Y

NC 09/20/2000 CLR -- N N

NC 09/20/2000 CLR --- N N

NC 09/20/2000 CLR -- N N

NC 09/20/2000 CLR --- N N

NC 09/20/2000 CLR -- N N

NC 09/20/2000 CLR -- N N

NC 09/20/2000 CLR --- N N

NC 09/2012000 CLR -- N N

NC 09/20/2000 CLR --- N N

NC 09/20/2000 CLR --- N N

NC 09/20/2000 CLR --- N N

NC 09/20/2000 CLR 60.30% N Y

NC 09/20/2000 CLR --- N N

NI 09/12/2000 CLR 59.70% N Y

NI 09/12/2000 CLR --- N N

NI 09/07/2000 CLR - N N

NI 09/07/2000 CLR --- N N

NI 09/0712000 REC -- Y N

NI 09/07/2000 CLR --- N N

NI 09/12/2000 CLR 59.61% N Y

NI 09/12/2000 CLR - N N

NI 09/12/2000 REC -- Y N

Page 66: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

EOC 13

Plant: McGuire 2

ITEM NUMBER B09.011.166A

B09.011.167

B09.011.167A

B09.040.006

B09.040.017

B09.040.018

B09.040.050

B09.040.051

B09.040.052

B09.040.053

B09.040.054

B09.040.055

B09.040.056

C01.030.011

C01.030.012

C02:021.007

C02.021.007A

C03.020.010

C05.011.021

C05.011.021A

C05.011.030

C05.011.030A

C05.011.034

C05.011.034A

C05.011.104

C05.011.104A

C05.011.126

C05.011.126A

C05.011.129

C05.011.129A

C05.011.151

C05.011.151A

C05.011.152

C05.011.152A

C05.011.159

C05.011.159A

C05.011.163

Run D Page 2

12/0612000

ID NUMBER

2N12F496

2N12F866

2N12F866

2NC2FW40-1

2NC2FW40-12

2NC2FW40-14

2N12FW89-1

2N12FW89-3

2NI2FW89-4

2N12FW89-5

2N12FW89-6

2N12FW89-7

2N12FW89-8

2BCSHX-50-B

2BCSHX-50-A

2SGC-W259

2SGC-W259

2MCA-ND-6123

2NDP109-1

2NDPI09-1

2ND2F-202

2ND2F-202

2ND2FW16-18

2ND2FW16-18

2N12F440

2NI2F440

2NIP145-1

2NIP145-1

2N12F493

2N12F493

2N12FW26-4

2N12FW26-4

2N12FW26-10

2NI2FW26-10

2N12F449

2N12F449

2N12F443

DUKE ENERs- .ORPORATION QUALITY ASSURANCE TECHNICAL SERVICES

In-Service Inspection Database Management System McGuire 2 Inservice Inspection Listing

Interval 2 Outage 5 SYSTEM INSP DATE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS

NI 09/12/2000 CLR -- N N

NI 09/12/2000 CLR --- N N

NI 09/12/2000 CLR -- N N

NC 09/18/2000 CLR -- N N

NC 09/08/2000 CLR --- N N

NC 09/08/2000 CLR --- N N

NI 09/08/2000 CLR -- N N

NI 09/08/2000 CLR --- N N

NI 09/08/2000 CLR -- N N

NI 09/18/2000 CLR --- N N

NI 09/18/2000 CLR --- N N

NI 09/18/2000 CLR -- N N

N I 09/18/2000 CLR -- N N

NS 08/29/2000 REC --- Y N

NS 08/29/2000 REC -- Y N

SM 09/23/2000 CLR 74.40% N Y SM 09/22/2000 CLR -- N N

ND 08/31/2000 CLR --- N N

ND 08/29/2000 CLR --- N N

ND 08/29/2000 CLR --- N N

ND 08/29/2000 CLR --- N N

ND 08/29/2000 CLR --- N N

ND 08/30/2000 CLR -- N N

ND 08/30/2000 CLR --- N N

N I 09/13/2000 CLR -- N N

NI 09113/2000 CLR -- N N

NI 09/16/2000 CLR -- N N

NI 09/16/2000 CLR --- N N

N I 09/12/2000 CLR 59.86% N Y NI 09/12/2000 CLR -- N N

N I 09/13/2000 CLR --- N N

NI 09/1312000 CLR --- N N

N I 09/13/2000 CLR --- N N

N I 09/13/2000 CLR --- N N

N I 09/13/2000 CLR --- N N

N I 09/13/2000 CLR - N N

N I 09/13/2000 CLR --- N N

Page 67: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

EOC 13

Plant: McGuire 2

ITEM NUMBER ID NUMBER C05.011.163A 2N12F443 C05.011.164 2N12F590 C05.011.164A 2N12F590

C05.011.165 2N12F591 C05.011.165A 2N12F591 C05.021.008 2N12F535 C05.021.008A 2N12F535 C05.021.017 2N12F-693 C05.021.017A 2N12F-693 C05.021.063 2NV2FW1 16-2 C05.021.063A 2NV2FWI 16-2 C05.021.072 2NV2FW292-3 C05.021.072A 2NV2FW292-3 C05.021.081 2RCPA-TE C05.021.081A 2RCPA-TE C05.021.087 2NV2FW33-23

C05.021.087A 2NV2FW33-23 C05.021.090 2NV2FW101-1

C05.021.090A 2NV2FW101-1 C05.021.099 2NV2FW54-16

C05.021.099A 2NV2FW54-16 C05.030.008 2NI2FW33-9 C05.030.052 2NV2FW101-7 C05.030.061 2NVP182-1 C05.030.070 2NV2FW235-4 C05.030.079 2NV2FW303-15 C05.051.002 2CA2FW45-27 C05.051.002A 2CA2FW45-27 C05.051.003 2CA2FW45-21 C05.051.003A 2CA2FW45-21 C05.051.011 2CA2FW51-25 C05.051.011A 2CA2FW51-25 C05.051.204 2SM5C-D

C05.051.204A 2SM5C-D C05.051.209 2SM2F-22 C05.051.209A 2SM2F-22 C05.051.215 2SM2F-72

Run D Page 3

1210612000

DUKE ENERL ,ORPORATION QUALITY ASSURANCE TECHNICAL SERVICES

In-Service Inspection Database Management System McGuire 2 Inservice Inspection Listing

Interval 2 Outage 5 SYSTEM INSP DATE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS

NI 09/13/2000 CLR -- N N

NI 08/31/2000 REC --- Y N

NI 08/30/2000 CLR --- N N

NI 08/31/2000 CLR --- N N

NI 08/30/2000 CLR --- N N

NI 09W16/2000 CLR -- N N

NI 09/16/2000 CLR -- N N

NI 08/31/2000 CLR -- N N

NI 08/31/2000 CLR --- N N

NV 09/26/2000 CLR -- N N

NV 09/26/2000 CLR --- N N

NV 08/30/2000 CLR -- N N

NV 08/30/2000 CLR -- N N

NV 08/31/2000 CLR 58.17% N Y NV 08/31/2000 CLR --- N N

NV 08/31/2000 CLR --- N N

NV 08/31/2000 CLR --- N N

NV 09/16/2000 CLR --- N N

NV 09/16/2000 CLR --- N N

NV 09/06/2000 CLR --- N N

NV 09/06/2000 CLR --- N N

NI 09/13/2000 CLR --- N N

NV 09/16/2000 CLR --- N N

NV 09/06/2000 CLR --- N N

NV 09/16/2000 CLR --- N N

NV 08/31/2000 CLR --- N N

CA 09/16/2000 REC -- Y N

CA 09/16/2000 CLR --- N N

CA 09/15/2000 CLR --- N N

CA 09/15/2000 CLR -- N N

CA 09/23/2000 REC -- Y N

CA 09/23/2000 CLR -- N N

SM 09/15/2000 CLR --- N N

SM 09/15/2000 CLR - N N

SM 09/17/2000 REC -- N N

SM 09/16/2000 CLR -- N N

SM 09/09/2000 CLR - N N

Page 68: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

EOC 13

Plant: McGuire 2

ITEM NUMBER C05.051.215A C05.051.217 C05.051.217A C05.051.220 C05.051.220A C05.051.252 C05.051.252A C05.051.300 C05,051.300A C05.051.301 C05.051.301A D02.020.040 D02.020.041 F01.010.102A F01.010.103A F01.020.078B F01.020.079C F01.020.080C F01.020.108B F01.020.1228 F01.020.224B F01.020.225B F01.020.250A F01.020.251C F01.020.264A F01o.030.154B F01.030.155B F01.030.156A F01.030.157B F01.040.005 F01.040.023

DUKE ENERG. JRPORATION lUALITY ASSURANCE TECHNICAL SERVICES ervice Inspection Database Management System

McGuire 2 Inservice Inspection Listing Interval 2 Outage 5

INSP STATUS INSP LIMITED GEO REF RFRID NUMBER 2SM2F-72

2SM2FW13-10

2SM2FW13-10

2SGA-W138

2SGA-W138

2SV2FW9-7

2SV2FW9-7

2VP2FW1-4

2VP2FW1-4

2VP2FW2-1

2VP2FW2-1

2MCA-RN-3083

2MCA-RN-3086

2MCR-NV-4443

2MCR-NV-4438

2MCA-FW-5009

2MCA-FW-5160

2MCA-FW-5180

2MCA-ND-6108

2MCA-ND-6117

2MCA-NS-5305

2MCA-NS-5308

2-MCA-S-NI-504-I-K

2-MCA-S-NI-504-I-L

2MCR-NV-5191

2MCA-RN-3028

2MCA-RN-3083

2MCA-RN-3086

2MCA-RN-3045

2RCP-B-SUPPORT

2RNP-SUP-2B

SYSTEM SM SM SM SM SM SV SV VP VP VP VP RN RN NV NV FW FW FW ND ND NS NS NV NV NV RN RN RN RN NC RN

C In-S

INSP DATE 09/08/2000 09/1512000 09/15/2000 09/16/2000 09/16/2000 09/15/2000 09/15/2000 09/07/2000 09/07/2000 09/07/2000 09/07/2000 08/30/2000 08/22/2000 09/02/2000 09/06/2000 08/22/2000 08/22/2000 08/22/2000 08/22/2000 08/22/2000 08/22/2000 08/22/2000 08/22/2000 08/22/2000 09/06/2000 08/22/2000 08/30/2000 08/22/2000 08/22/2000 09/06/2000 08/22/2000

CLR CLR CLR CLR CLR

CLR CLR CLR CLR CLR CLR

CLR

CLR CLR

CLR CLR CLR

CLR CLR CLR

CLR CLR CLR CLR CLR REC

CLR

CLR

CLR

CLR

CLR

N N

N

N

N

N

N

N

N

N

N

N

N

N

N

N

N

N

N

N

N

N

N

N

N

N

N

N

N

N

N

N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N

Run D Page 4

12/0612000

COMMENTS

Page 69: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

5.2 Limited examinations (i.e., 90% or less of the required examination coverage obtained) identified during Outage 5/EOC-13 are shown below. A Request for Relief will be submitted for NRC approval. Reference Section 9 for additional information.

Item Number

B09.011.032

B09.011.039

B09.011.162

B09.011.165

C02.021.007

C05.011.129

C05.021.081

Request for Relief Serial Number

01-001

01-001

01-001

01-001

01-001

01-001

01-001

Outage 5/EOC-13 McGuire Unit 2 Section 5

Page 2 of 2 Revision 0 December 6, 2000

Page 70: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

6.0 Reportable Indications

Outage 5/EOC-1 3 had no reportable indications.

Outage 5/EOC-13 McGuire Unit 2 Section 6

Page 1 of 1 Revision 0 December 6, 2000

Page 71: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

7.0 Personnel. Equipment and Material Certifications

All personnel who performed or evaluated the results of inservice inspections from to April 16, 1999 to October 13, 2000 at McGuire Nuclear Station, Unit 2, were certified in accordance with the requirements of the 1989 Edition of ASME Section Xl with no addenda including Appendix VII for ultrasonic inspections. In addition, ultrasonic examiners were qualified in accordance with ASME Section XI, Appendix VIII, and 1992 Edition with the 1993 Addenda through the Performance Demonstration Initiative (PDI) for similar metal piping welds. The appropriate certification records for each inspector are on file at McGuire Nuclear Station or copies can be obtained by contacting the Duke Energy's Corporate Office in Charlotte, North Carolina.

Records of periodic calibration of inspection equipment are on file at Nuclear Station or copies can be obtained by contacting the Duke Corporate Office in Charlotte, North Carolina.

Records of materials used, (i.e., NDE consumables) are on file at Nuclear Station or copies can be obtained by contacting the Duke Corporate Office in Charlotte, North Carolina.

McGuire Energy's

McGuire Energy's

Outage 5IEOC-13 McGuire Unit 2 Section 7

Page 1 of 1 Revision 0 December 6, 2000

Page 72: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

8.0 Corrective Action

No corrective action was required as a result of examinations performed during Outage 5/EOC-13.

Outage 5[EOC-13 McGuire Unit 2 Section 8

Page 1 of 1 Revision 0 December 6, 2000

Page 73: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

9.0 Reference Documents

The following reference documents apply to the inservice inspection performed during Outage 5/EOC-1 3 at McGuire Unit 2. A copy of these can be obtained by contacting the ISI Plan Manager at Duke Energy's Corporate Office in Charlotte, North Carolina:

Request for Relief 01-001

Outage 5/EOC-13 McGuire Unit 2 Section 9

Page 1 of 1 Revision 0 December 6, 2000

Page 74: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

10.0 Class I and 2 Repairs and Replacements

As required by ASME Section Xl 1989 Edition, no Addenda, a record of (Form NIS-2) the Class I and Class 2 Repairs and Replacements for work performed from April 16, 1999 to October 13, 2000 is provided and is included in this section of the report. The individual work request documents are on file at McGuire Nuclear Station.

Outage 5/EOC-13 McGuire Unit 2 Section 10

Page 1 of 1 Revision 0 December 6, 2000

Page 75: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section X1

1. Owner Address: Duke Power Company

526 S. Church Street, Charlotte, NC 28201-1006

2. Plant Address:

la. Date May 18, 1999 Sheet 1 of I

McGuire Nuclear Station

12700 Hagers Ferry Road, Huntersville, NC 28078

2a. Unit: 01 E12 03 r'Shared (specify Units _

3. Work Performed By: Duke Power Company 3a. Work Order#:

Address: 526 S. Church Street, Charlotte NC 28201-100698043857

RepeJr Oganiz Job #

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A

4. (a) Identification of System: NC - Reactor Coolant 4. (b)

5. (a) Applicable Construction Code: AWE HI 197t Edition, Summer and Winter Addenda,

(b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1989, No Addenda

6. Identification of Components Repaired or Replaced and Replacement Components:

3b. NSM or MM #:

Class of System: A

N/A

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Repaired, Replaced, or ASME Code Stamped

Replacement (yes or no)

A E Repaired, 03 No 2A Steam Generator B&W 770002 159 N/A 1996 03 Replaced,

__Replacement 0Yes B 0 Repaired, 03 No

o3 Replaced,

[] Replacement 0 Yes

C 0 Repaired, 0 No o Replaced, [o Replacement 0 Yes r-I E3 h,,- I--r ki

O3 Replaced, O Replacement

________________ -t t "r � .�. I U t-tepairea, Li NOR epaired, "0 Replaced,

"0 Replacement_____ .1 1 I t.-. - -. u I-¶epaireU, U P40

uRtepalreu, "0 Replaced, "O Replacement

03 Yes

U NO

13 Yes

N Yo

0 Yes

Page I of 2 Revision 5

N/A

Code Cases

D

E

F

Page 76: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replaced Studs

8. Test Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. 0

9. Remarks

Other 0 Exempto

Pressure _ __psig Test Temp. OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A

Signed ,.ý Q FL Grass Jr.,QA Tech Specialist Date h,/ , 19 Owner odvwners Designee, Weite

Page 2 of 2 Revision 5

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have inspected th omponents described in this Owners Report during the period A ý .4 tcto. S±--2 ; and state that to the best of my knowledge and belief, the Owner has performed examinatiohs and taken corrective measures described in this Owners Report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

"Commissions r%7"7dý o 1 Q3C '3", --Inspec or'" ature National Board, State, Province and Endorsements

Date 1.9-YT

Page 77: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S hr-PORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xl

1. Owner Address: Duke Power Company

526 S. Church Street, Charlotte, NC 28201-1006

2. Plant Address:

la. Date May18,1999

Sheet 1 of 1

McGuire Nuclear Station

12700 Hagers Ferry Road, Huntersvtlle, NO 28078

2a. Unit: 01 E12 03 OShared (specify Units

3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A

4. (a) Identification of System: NC - Reactor Colloant

3a. Work Order#:

3b. NSM or MM

4. (b) Class of System: A

98043858 R~epr Organizs~wr Job #

N/A

5. (a) Applicable Construction Code: ASME II1971 Edition, Summer and Winter Addenda,. (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989, No Addenda

6. Identification of Components Repaired or Replaced and Replacement Components:

N/A Code Cases

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Repaired, Replaced, or ASME Code Stamped

Replacement (yes or no) A 0 Repaired, 0 No

28 Steam Generator B&W 770004 161 N/A 1996 0 Replaced, EReplacement 0Yes

B 0 Repaired, 0 No o Replaced,

__ Replacement 0 Yes C 0 Repaired, 0 No

0 Replaced,

[0 Replacement 0 Yes

D 0 Repaired, 0 No 0[ Replaced, [o Replacement 0 Yes

E 0 Repaired, 0 No 0 Replaced, ]0 Replacement 0 Yes

F 0 Repaired, 0 No o Replaced, _0 Replacement 0 Yes

Page I of 2 Revision 5

Page 78: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of WorkRDlaced stud #16R

8. Test Conducted:Hydrostatic 0 Pneumatic l1 Nom. Operating Press. 9 Oither 11 Exemptol

9. Remarks

Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A

Signed FL Grass Jr..QA Tech Specialist Date 5 '/ 19 Owneror• Owner's Designee, Title

Page 2 of 2 Revision 5

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connectict ,ha e inspected the,,components described in this Owner's Report during the period - -P- to,.a -F -FY; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions MZ77aý4 ,/3-7 fns t r' S' ture 0e- National Board, Stat4, Province and Endorsements

Date 12P 1917

-

-- ! ........... ., ov

Page 79: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xl

1. Owner Address: Duke Power Company

526 S. Church Street, Charlotte, NC 28201-1006

2. Plant Address:

la. Date May18,1999

Sheet 1 of 1

McGuire Nuclear Station

12700 Haners Ferry Road, Huntersville, NC 28078

2a. Unit: 01 122 03 OShared (specify Units

3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201 -1006

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A

4. (a) Identification of System: NC - Reactor Coolant

3a. Work Order #:

3b. NSM or MM #:

98043860 Repir Organiaq Jd #

N/A

4. (b) Class of System: A

5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda,

(b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1989, No Addenda

6. Identification of Components Repaired or Replaced and Replacement Components:

N/A Code Cases

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Repaired, Replaced, or ASME Code Stamped

Replacement (yes or no)

A 03 Repaired, 03 No 2D Steam Generator B&W 770003 160 N/A 1996 01 Replaced,

RI Replacement ERYes B 0l Repaired, 01 No

03 Replaced,

E0 Replacement 03 Yes C 10 Repaired, 03 No

03 Replaced, E3 Replacement 0 Yes

D 10 Repaired, 03 No 03 Replaced, _3 Replacement 0 Yes

E 03 Repaired, 03 No 03 Replaced, 03 Replacement 03 Yes 03 Repaired, 03 No 03 Replaced, _0 Replacement 0 Yes

Page 1 of 2 Revision 5

Page 80: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replaced stud #2

8. Test Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. El Other El Exempto

Pressure _psig Test Temp. - F Pressure _ _ psig Test Temp. F__ F Pressure _ _ psig Test Temp. OF

9. Remarks

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A

Signed ýý" a FL Grass Jr..QA Tech Specialist Date 19 __• "Owner,( Owners Designee, Title

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of --North Carolina and employed by HSBI and I Company of Hartford Connecticut have inspected the components described in this Owner's Report during the period i'i• " to and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection:

Commissions i\)_%77 ýýi, A'SS3', AJT Inspector's %nature National Board, state, Province and Endorsements

Date 9

Page 2 of 2 Rcvision 5

Page 81: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S hr-t'ORT FOR REPAIRS OR REPLACEMENTS As Required By The Provlslons Of The ASME Code Section X1

1. Owner Address: Duke Power Company

526 S. Church Street, Charlotte, NC 28201-1006

2. Plant Address:

la. Date May 25, 1999

Sheet 1 of 1

McGuire Nuclear Station

12700 i-iaqers Ferry Road, Huntersville, NC 28078

2a. Unit: 01 R12 03 OShared (specify Units

3. Work Performed By: Duke Power Company Address: 526 S. Church Street. Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No.. N/A Expiration Date: N/A

4. (a) Identification of System: NI - Safety Injection

3a. Work Order#:

3b. NSM or MM #:

98044201 RertrgnOizfwhoi Job

N/A

4. (b) Class of System: A

5. (a) Applicable Construction Code: ASME Ill 1971 Edition, Summer and Winter Addenda, (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989, No Addenda

6. Identification of Components Repaired or Replaced and Replacement Components:

N/A Code Cases

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Repaired, Replaced, or ASME Code Stamped

Replacement (yes or no)

A E3 Repaired, o3 No

2NI-0070 Walworth A1344 564 N/A 1976 03 Replaced, I__Replacement IYes

B 0 Repaired, 03 No o Replaced,

__ Replacement 03 Yes C 0 Repaired, 0 No

O3 Replaced, o Replacement 0 Yes

D 0 Repaired, 03 No o3 Replaced,

_0Replacement 0 Yes E 0 Repaired, 0 No

O3 Replaced,

10 Replacement 0 Yes 03 Repaired, 03 No 03 Replaced,

_0 Replacement 03 Yes

Page 1 of 2 Revision 5

Page 82: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replaced Disc

8. Test Conducted:Hydrostatic 51 Pneumatic 51 Nom. Operating Press. 1Z Other 0 Exempts

Pressure _psig Test Temp. OF Pressure j psig Test Temp. _ F Pressure psig Test Temp. OF

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A

Signed .- ,, FL Grass Jr.,QA Tech Specialist Date 19 q Owner ofOwner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut hav 1 inspected the components described in this Owners Report during the period -3to and state that to the best of my knowledge and belief, the Owner has perforrhed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

SCommissions &J% 77 q 7 6 ,q Inspecto S ia re National Board, State Province and Endorsements Date--- 199 " - 9_q

Pagc 2 of 2 Revision 5

Page 83: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xl

1. Owner Address: Duke Power Comipanv

526 S. Church Street, Charlotte, NC 28201-1006

2. Plant Address:

la. Date May11,1999 Sheet 1 of 1

McGuire Nuclear Station

12700 Hagers Ferry Road, Huntersville, NC 28078

2a. Unit: 0`1 E12 03 []Shared (specify Units

3. Work Performed By: Duke Power Company 3a. Work Order #:

Address: 526 S. Church Street, Charlotte NC 28201-100698142149

Repair Organizeiioý Job #

Type Code Symbol Stamp: N/.A Authorization No. N/A Expiration Date: N/A

4. (a) Identification of System: NV - Chemical and Volume Control

5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda,_ (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1989, No Addenda

3b. NSM or MM #:

4. (b) Class of System: A

N/A

6. Identification of Components Repaired or Replaced and Replacement Components:

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Repaired, Replaced, or ASME Code Stamped

. Replacement (yes or no)

A 0 Repaired, 0 No

2NV-14 Walworth A0658 244 N/A 1974 0 Replaced, _ _ Replacement WYes

B 0 Repaired, 0 No o3 Replaced, [3 Replacement 03 Yes

C 0 Repaired, 03 No o3 Replaced, _0 Replacement 0 Yes

D 0 Repaired, 0 No 0 .Replaced, O Replacement 0 Yes

E Repaired, 0 No

o Replaced, _ _ Replacement 0 Yes

F 0 Repaired, 0 No 03 Replaced, _0 Replacement 0 Yes

Page 1 of 2 Revision 5

N/A

Code Cases

Page 84: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replaced 12 body to bonnet studs with 24 nuts

8. Test Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. [] Other EJ Exempt[

Pressure _psig Test Temp. OF Pressure psig Test Temp. O__ _F Pressure psig Test Temp. OF

9. Remarks

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A

Signed - , jI, FL Grass Jr.,QA Tech Specialist Date 5 ', 1999 Owner 6r Owners Designee, TMtle

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have inspected the components described in this Owners Report during the period to and state that to the best of my knowledge and belief, the Owner has perfor•ed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

S~~~Commissions&%7 ,7 ad MýM M4- £ Inspecor's SignaCmso Nationai Board, S(ate, Province and'Endorsements

Date 19C79gj

Page 2 of 2 Revision 5

Page 85: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner Address: Duke Power Company

526 S. Church Street, Charlotte, NC 28201-1006

2. Plant Address:

1 a. Date September 11, 2000

Sheet 1 of 1

McGuire Nuclear Station

12700 Hagers Ferry Road, Huntersville, NC 28078

2a. Unit: 01 0•2 03 DShared (specify Units .)

3. Work Performed By: Duke Power Compan I' Address: 526 S. Church Street, Charlofte NC 28201-1006

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A

4. (a) Identification of System: NI - Safety Injection

3a. Work Order # :

3b. NSM or MM #:

98220269 Repir Organ=zafe Jcb*

N/A

4. (b) Class of System: A

5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1989, No Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)

6. Identification of Components Repaired or Replaced and Replacement Components:

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Repaired, Replaced, or ASME Code Stamped

Replacement (yes or no)

A 0 Repaired, 0 No 2-MCR-NI-4556 Duke Power," 14984 N/A N/A N/A OReplaced,

S...._ [ Replacement 03 Yes

B 03 Repaired, []No 2-MCR-NI-4556 Duke Power 21122 N/A N/A N/A 03 Replaced,

__Replacement 03 Yes C 03 Repaired, 0 No

0 Replaced, _0 Replacement 0 Yes

D 10 Repaired, 03 No 0. Replaced,

_3 Replacement 03 Yes E0 Repaired, 0 No 0 Replaced,

E3 Replacement 0 Yes F [0 Repaired, 03 No

0 Replaced,

_3 Replacement 0 Yes

Page 1 of 2 Revision 6

Page 86: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of WorkRenlaced sniihh�r

8. Test Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. 01 Other 0 Exemptl9

9. Remarks

Pressure psig Test Temp. OF Pressure _ _ psig Test Temp. OF Pressure psig Test Temp. OF

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPUANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A

Signed \• • FL Grass Jr.. QA Tech Specialist Date !/!, 2 Owvner,'r Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of --North Carolina and employed by HSBI and I Company of Hartford Connecticut have inspected the components described in this Owners Report during the pedod °rQ". to.J:-l l'-06 ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

kAA R.D. KleininspdctoisiSignature

Date .1L _a-o00Commissions

National Board, State, Province and Endorsements

Page 2 of 2 Revision 6

NB7728, NC853. N-1

Renlaced -qni hhpr

Page 87: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME!Code Section X1

1. Owner Address: Duke Power Company

526 S, Church Street, Charlotte, NC 28201-1006

1 a. Date October 10, 2000 Sheet 1 of 1

2. Plant Address: McGuire Nuclear Station t 12700 Hagqers Ferry Road, Huntersville. NC 28078

2a. Unit: 01 02 03 r'Shared (specify Units

3. Work Performed By: Duke Power Comoanv 3a. Work Order#:

Address: 526 S. Church Street, Charlotte NC 28201 -100698243414

Reper Or If Jd$#

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A

4. (a) Identification of System: NC - Reactor Coolant 4. (b)

3b. NSM or MM #:

Class of System: A

N/A

5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda. N/A Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989, No Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)

6. Identification of Components Repaired or Replaced and Replacement Components:

Column I Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name ol Component Name of Mfg Mfg Serial No. National Board No. Other Identlicati-on Year Built Repaired, Replaced, or ASME Code StampedI

Replacement (yes or no) A 13 Repaired, 03 No

2-NC-VA-0003 Crosby N56925-00-0002 26 N/A 1974 I Replaced, 13 Replacement 0Yes

B 03 Repaired, 03 No 2-NC-VA-0003 Crosby N56925-00-0001 25 N/A 1974 [] Replaced,

.. _ _ _Replacement OYes C 13 Repaired, [] No

03 Replaced, _E Replacement El Yes

D 03 Repaired, 0 No Q Replaced,

[O Replacement [] Yes

E E3 Repaired, 03 No o3 Replaced, _3 Replacement 03 Yes rI D ; r K I

O Replaced, O Replacement 03 Yes

Page 1 of 2 Revision 6

F

Page 88: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in items1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replaced valve

8. Test Conducted:Hydrostatic El Pneumatic El Nom. Operating Press. 12 Other El Exempto

Pressure 2235 psig Test Temp. 557 OF Pressure ___psig Test Temp. - IF Pressure _ psig Test Temp. _ OF

9. Remarks test was performed per work order 98243956 / 01 under procedure MP/0/A7650/076.

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A

Signed FL Grass Jr., QA Tech Specialist Date -1-0"6 4 OwnerO Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have inspected the components described in this Owners Report during the period - to Ib -/6-00 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in the Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

RR.D. Klein Commissions NB7728, NC853, N-I nS r. nature _ D.nalurn-- National Board, State, Province and Endorsements

Date. 10-1 &00,0

'---.

Page 2 of 2 Revision 6

Page 89: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASJIVE Code Section XI

1. Owner Address: Duke Power Company

526 S. Church Street, Charlotte, NC 28201-1006

2. Plant Address:

la. Date October 12, 2000 Sheet 1 of 1

McGuire Nuclear Station

12700 Haaers Ferry Road. Huntersville, NC 28078

2a. Unit: 01 02 03 OShared (specify Units -

3. Work Performed By: Duke Power Comoany Address: 526 S, Church Street. Charlotte NC 28201-1006

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A.

4. (a) Identification of System: NC • Reactor Coolant

3a. Work Order #: noAA141

Rtemki Ormwfzsio Jeb#

3b. NSM or MM #: N/A

4. (b) Class of System: A

5. (a) Applicable Construction Code: ASMUI 11971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1989, No Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)

6. Identification of Components Repaired or Replaced and Replacement Components:

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Repaired, Replaced, or ASME Code Stamped

Replacement (yes or no)

A 10 Repaired, 03 No

2A Steam Generator B & W 770002 159 N/A 1996 0 Replaced, 0_ Replacement IYes

B 0 Repaired, 0 No 03 Replaced,

3 0 Replacement 03 Yes C El Repaired, 03 No

03 Replaced,

03 Replacement 03 Yes

D 03 Repaired, 03 No 0, Replaced,

.E3_ Replacement 0 Yes

E 0 Repaired, 0 No 03 Replaced, _3 Replacement 0 Yes

F -0 Repaired, 0 No 03 Replaced, _0 Replacement 0 Yes

Page 1 of2 Revision 7

Page 90: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replaced one primary manway stud (18)

8. Test Conducted:Hydrostatic 5 Pneumatic 5 Nom. Operating Press. R1 Other 0 Exempts

Pressure psig Test Temp. O__ _F Pressure .psig Test Temp. OF Pressure psig Test Temp. F__ F

9. Remarks The test was performed per work order number 98243956 / 01 during the class A walkdown.

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A

Signed S-4 , FL Grass Jr., OA Tech Specialist Date ,., Ownerd& Owner's Designee, Te/

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have Inspected the components described in this Owner's Report during the period _.-.Ca -Q00 to 4:242 -Qg and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report In accordance with the requirements of ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_R.D. Klein Commissions NB7728, NC853, N-I Inspedtor~ignae National Board, State, Province and Endorsements

Page 2 of 2 Revision 7

Date (-I -.a kooo

Page 91: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPORT As Required By The Provisio,

REPAIRS OR REPLACEMENTS Ahe ASME Code Section XI

1. Owner Address:

2. Plant Address:

la. Date

Sheet

Duke Power Company

526 S. Church Street, Charlotte, NC 28201-1006

Mcguire Nuclear Station

12700 Hagers Ferry Road, Huntersville, NC 28078

2a. Unit: " 1 Z 2 [] 3 [] Shared (specify units)

3. Work Performed By: Duke Power Company 3a. Work Order #

Address: 526 S. Church Street. Charlotte, NC 28201-1006 Repai

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 3b. NSM or MM #

4. (a) Identification of System: NC 4. (b) Class of System: A

5. (a) Applicable Construction Code: ASME m 1971 Edition, Summer and Winter Addenda, N/A Code Cases

(b) Applicable Edition of Section XI Utilizing for Repairs or Replacements: 1989, No Addenda (1992 through 1992 Addenda for Class MC

6. Identification of Components Repaired or Replaced and Replacement Components:

98245228/08 r Organization Job #

N/A

and CC and their supports)

Page I of2 Revision 7

10/06/00

1 of I

Column 1 Column 2 Column 3 Column 4 Column 5 Col. 6 Column 7 Column 8 Repaired, ASME Code Name of Component Name of Mfg. Mfg. Serial No. National Other Year Replaced, or Stamped (yes or

Board No. Identification Built Replacement no)

O] Repaired, [] No

A 2MCR-NC-4783 DUKE POWER N/A N/A N/A N/A [ Replaced,

ID Replacement Q Yes [] Repaired, E3 No

B [3 Replaced,

0o Replacement 0 Yes [o Repaired, 0 No

C EO Replaced, 0O Replacement El Yes [o Repaired, 0 No

D [] Replaced, [0 Replacement 0 Yes [o Repaired, 0 No

E [] Replaced,

""O Replacement [0 Yes "O Repaired, 0 No

F [] Replaced,

0] Replacement 0 Yes

Page 92: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS -2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of work: Replaced pipe clamp

8. Test Conducted : Hydrostatic [I Pneumatic 0 Nom. Operating Press. 0 Other 0 Exempt 0

Pressure psig Test Temp OF Pressure psig Test Temp OF Pressure psig Test Temp OF

9. Remarks:

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that he statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A Expiration Date N/A Signed F. R. Sorrow Exec. Supp. Date 10/06 20 00

Owner or Owner's Designee, Title

Page 2 of 2

Rvikx)n 7

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid conmmission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have inspected the components described in this Owner's Report during the period - to -O-(3 ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

R. D. Klei ,rL•.. , Commissions NB7728, NC853, N-I Inspector's•'Jgture National Board, State, Province and Endorsei

Date 1. 6 , 20__.,ments

Page 93: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPOR" As Required By The Provisi,

"REPAIRS OR REPLACEMENTS The ASME Code Section XI

1. Owner Address:

2. Plant Address:

Ia. Date

Sheet

Duke Power Company

526 S. Church Street. Charlotte, NC 28201-1006

Mcguire Nuclear Station

12700 Hagers Ferry Road, Huntersville, NC 28078

2a. Unit: [ 1 ED 2 [1 3 F] Shared (specify units)

3. Work Performed By: Duke Power Company

09/30/00

1 of 1

3a. Work Order # 98312705/01 'PAný6r -- ~nTt-n TM, A4

Address: 526 S. Church Street. Charlotte, NC 28201-1006 -1 .. .... .

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 3b. NSM or MM # 11970

4. (a) Identification of System: NI 4. (b) Class of System: A

5. (a) Applicable Construction Code: ASME M 1971 Edition, Summer and Winter Addenda, N/A Code Cases

(b) Applicable Edition of Section XI Utilizing for Repairs or Replacements: 1989, No Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)

6. Identification of Components Repaired or Replaced and Replacement Components:

Column 1 Column 2 Column 3 Column 4 Column 5 Col. 6 Column 7 Column 8

Name of Component Name of Mfg. Mfg. Serial No. National Other Year Repaired, ASME Code Board No. Identification Built Replacement no)

o] Repaired, 0] No A 2MCR-NI-4122 DUKE POWER N/A N/A S/N-10404 N/A 0 Repaced,

[] Replaced, [o Replacement El Yes

B 2MCR-NI-4122 DUKE POWER N/A N/A S/N-61224-70 N/A [ Repaired, 0 No o Replaced, ]0 Replacement [3 Yes

C 0 Repaired, 03 No C0 Replaced,

1 0 Replacement 0 Yes D o Repaired, 0 No

D0 Replaced,

EO Replacement 0 Yes E [] Repaired, El No

E Replaced,

D_ Replacement 0l Yes F E Repaired, El No

F0 Replaced,

[] Replacement El Yes

P.ge I of 2 Revision 7

Page 94: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS -2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used , provided (1) size is 8 1/2 in. x 11 in. (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of work: Replaced Mech. Snubber with Lesiga HYD.

Snubber

8. Test Conducted: Hydrostatic " Pneumatic 0 Nom. Operating Press. 0 Other 0 Exempt l

Pressure psig Test Temp OF Pressure psig Test Temp OF Pressure psig Test Temp OF

9. Remarks:

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that he statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed F. R. Sorrow Exec. Sit Date 09/30 20 00

Owner or Owner s Designee, Title

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have inspected the components described in this Owner's Report during the period q-1 2-f--O) to 'q-0".,-•) ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

R. D. Klein Commissions NB7728, NC853, N-I Inspector's Si•a Yure National Board, State, Province and Endorsements

Date •'2C) , 20C"

Page 2 of 2 Rc'qsmon 7

Page 95: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section X1

1. Owner Address:

2. Plant Address:

Duke Power Company

526 S. Church Street, Charlotte, NC 28201-1006

McGuire Nuclear Station

1 a. Date September 27, 2000

Sheet 1 of 1

12700 Hagqers Ferry Road, Huntersville, NC 28078

2a. Unit: 01 02 013 r-Shared (specify Units

3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A

4. (a) Identification of System: NC - Reactor Coolant

3a. Work Order#: 98314147 Rep*Ir OrganlzazoJob#

3b. NSM or MM #: N/A

4. (b) Class of System: A

5. (a) Applicable Construction Code: ASMEIll 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1989, No Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)

6. Identification of Components Repaired or Replaced and Replacement Components:

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Repaired, Replaced, or ASME Code Stamped

-Replacement (yes or no)

A '0 Repaired, EINo 2-MCR-NC-4288 Duke Power 2443 N/A N/A N/A EIReplaced, 13 Replacement 03 Yes

B 0 Repaired, RINo 2-MCR-NC-4288 Duke Power 2365 N/A N/A N/A 03 Replaced,

RReplacement 03 Yes

C 0 Repaired, 03 No 13 Replaced, _0 Replacement 0 Yes

D 03 Repaired, 0 No

G, Replaced, [] Replacement 0 Yes E 0 Repaired, 0 No

03 Replaced, [0 Replacement 0 Yes 0 Repaired, 0 No 0 Replaced, _0 Replacement 03 Yes

Page 1 of 2 Revision 7

Page 96: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replaced Snubber

8. Test Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. 0 Other 0 Exemptlo

Pressure _psig Test Temp. - F Pressure psig Test Temp. OF Pressure psig Test Temp. OF

9. Remarks

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A

Signed V, FL Grass Jr., QA Tech Specialist Date .4 ' , 2

Owner 9fOwners Designee, Tite

Page 2 of 2 Revision 7

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have inspected the components described in this Owner's Report during the period to Sle ) to - and state that to the best of my knowledge and belief, the Owner h.s'performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in the Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. A .. ' R.D. Klein- Commissions NB7728, NC853, N-I

Inspector's 6ratur National Board, State, Province and Endorsements

Date

Page 97: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S r , FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xi

1. Owner Address: Duke Power Company

526 S. Church Street. Charlotte, NC 28201-1006

2. Plant Address:

la. Date May 19, 1999 Sheet 1 of 1

McGuire Nuclear Station

12700 Haiers Ferry Road, Huntersville, NC 28078

2a. Unit: 01 R12 03 OShared (specify Units

3. Work Performed By: ' Duke Power Company 3a. Work Order#:: Address: 526 S. Church Street, Charlotte NC 28201-1006

97050156Reer Orgwizadon Job#

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A

4. (a) Identification of System: NI -Safety Iniection

5. (a) Applicable Construction Code: ASME-Ill 19Z1 Edition, Summer and Winter Addenda, _ (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1989, No Addenda

6. Identification of Components Repaired or Replaced and Replacement Components:

3b. NSM or MM #:

4. (b) Class of System: B

N/A

N/A

Code Cases

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Repaired, Replaced, or ASME Code Stamped

Replacement (yes or no) A0 E Repaired, 0 No

2NI-14 BWPI 97EP0203 N/A N/A 1997 03 Replaced, IReplacement EIYes B0 Repaired, 0 No

o Replaced, _0 Replacement 0 Yes

C 0 Repaired, 0 No o Replaced, [0 Replacement 0 Yes

D 0 Repaired, 0 No 0 Replaced, _0 Replacement 0 Yes

E [0 Repaired, 0 No 0 Replaced, 0 Replacement 0 Yes F0 Repaired, 0 No 0 Replaced, _0 Replacement 0 Yes

Page 1 of 2 Revision 5

Page 98: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in items1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replaced Disc

8. Test Conducted:Hydrostatic 0i Pneumatic El Nom. Operating Press. R1 Other El Exemptfl

Pressure psig Test Temp. OF Pressure psig Test Temp. O_ F Pressure psig Test Temp. OF

9. Remarks

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A

Signed \--6.AW Q FL Grass Jr..QA Tech Specialist Date -5-/' 19 9 Owner or'Owner's Designee, Title

Page 2 of 2 Revision 5

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have inspected the components described in this Owner's Report during the period -- -9q to ,'-o..; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Inpcor _ _a_-_aCommissions Bo7a7qd, 16)a 1 e-!2' aE VsInspector' Sigau National Board, State, Province and Endforsements

Date- 5ýd 199q

Page 99: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S i (FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xl

1. Owner Address: Duke Power Company

526 S. Church Street, Charlotte, NC 28201-1006

2. Plant Address:

la. Date May 19, 1999 Sheet 1 of 1

McGuire Nuclear Station

12700 Haqers Ferry Road. Huntersville, NC 28078

2a. Unit: E1 02 03 OShared (specify Units

3. Work Performed By: Duke Power Companv Address: 526 S. Church Street, Charlotte NC 28201-1006

Type Code Symbol Stamp: N/A Authorization No. NIA Expiration Date: N/A

4. (a) Identification of System: NI - Safety Inlection

3a. Work Order#:

3b. NSM or MM #:

97050160 Repr Organizmon Job #

N/A

4. (b) Class of System: B

5. (a) Applicable Construction Code: ASME III 19Z1 Edition, Summer and Winter Addenda, (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989, No Addenda

N/A Code Cases

6. Identification of Components Repaired or Replaced and Replacement Components:

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Repaired, Replaced, or ASME Code Stamped

Replacement (yes or no)

A [3 Repaired, 03 No

2N1-18 BWPI 97EP0201 N/A N/A 1997 0 Replaced, OReplacement EYes

B [3 Repaired, 0 No O Replaced, E3 Replacement 0 Yes

C 0 Repaired, 0 No

O Replaced, [] Replacement 03 Yes

D [0 Repaired, 01 No O Replaced,

[] Replacement 0 Yes E 0 Repaired, 0 No

O1 Replaced,

[O Replacement 0 Yes 0 Repaired, 0 No

o Replaced,

0O Replacement 0 Yes

Page 1 of 2 Revision 5

Page 100: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in items1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Reolaced Disc

8. Test Conducted:Hydrostatic El Pneumatic 0 Nom. Operating Press. I Other El Exempt[]

9. Remarks

Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A

Signed FL Grass Jr.,QA Tech Specialist Date - / 19_.91_ Owner,"f Owner's Designee, Tide

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have inspected the components described in this Owner's Report during the period -3 -a.-91 to 6*-oD-; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions /\JB--77W A.-, , -- 7 Inspectors igature National Board, State, Province and Endorsements

Date S ? 9I

Page 2 of 2 Revision 5

Page 101: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S hi-PORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xl

1. Owner Address: Duke Power Company

526 S. Church Street, Charlotte, NC 28201-1006

2. Plant Address:

Ia. Date July20, 1999

Sheet 1 of 1

McGuire Nuclear Station

12700 Haaers Ferry Road, Huntersville, NC 28078

2a. Unit: 01 E12 03 OShared (specify Units

3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A

4. (a) Identification of System: ND - Residual Heat Removal

3a. Work Order #: 97107046Repair Or zation Jcb #

3b. NSM or MM

4. (b) Class of System: B

#: N/A

5. (a) Applicable Construction Code: ASME Il 11971 Edition, Summer and Winter Addenda, N/A Code Cases fb) Applicable Edition of Section Xi Utilized for Repairs or Replacements: 1989, No Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)

6. Identification of Components Repaired or Replaced and Replacement Components:

Column I Column 2 Column 3 Column 4 Column 6 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Sedal No, National Board No. Other Identification Year Built Repaired, Replaced, or ASME Code Stamped Replacement (yes or no)

A 0 Repaired, 03 No

2ND32 Kerotest KP13-12 7047 N/A 1975 03 Replaced, I_ Replacement IYes

B [ Repaired, 0 No o Replaced, 0_ Replacement 0 Yes

C 0 Repaired, 0 No O Replaced,

o Replacement 03 Yes D 10 Repaired, 0 No

0 Replaced, __ Replacement 0 Yes

E 0 Repaired, 0 No 03 Replaced, 0 Replacement 03 Yes

F 03 Repaired, 0 No 0 Replaced, 13 Replacement 10 Yes

Page 1 of2 Revision 6

Page 102: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replaced disc and bonnet

8. Test Conducted:Hydrostatic 0l Pneumatic El Nom. Operating Press. [1 Other 0] Exempt[E

Pressure _psig Test Temp. _ F Pressure .psig Test Temp. °F Pressure _psig Test Temp. OF

9. Remarks

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A

Signed -,- 4O) FL Grass Jr.,QA Tech Specialist Date July. 20 1999 "Owner o(:wner's Designee, Title

Page 2 of 2 Revision 6

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have inspected the components described in this Owner's Report during the period "n'-,3.-.to ýD?- 4 -and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

RgDt Klein Commissions NB7728, NC853. N-I inspect ' iNational Board, State, Province and Endorsements

Date oq

Page 103: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S r-rORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xl

1. Owner Address: Duke Power Company

526 S. Church Street, Charlotte, NC 28201-1006

2. Plant Address:

la. Date May 26, 1999

Sheet 1 of I

McGuire Nuclear Station

12700 Haagers Ferry Road, Huntersville, NC 28078

2a. Unit: 01 02 013 OShared (specify Units

3. Work Performed By: Duke Power ComDanv Address: 526 S. Church Street, Charlotte NO 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A

4. (a) Identification of System: CF - Feedwater

3a. Work Order#:

3b. NSM or MM #:Repeir Or IZl Jcb

N/A

4. (b) Class of System: B

5. (a) Applicable Construction Code: ASME Ill 1971 Edition, Summer and Winter Addenda,

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989, No Addenda

6. Identification of Components Repaired or Replaced and Replacement Components:

N/A Code Cases

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 • Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Repaired, Replaced, or ASME Code Stamped

Replacement s or no)

A 03 Repaired, 03 No CF Piping Duke Power N/A 61 N/A 1982 [0 Replaced,

EIReplacement EIYes

B 03 Repaired, 03 No 03 Replaced, _0 Replacement 0 Yes 03 Repaired, 03 No 03 Replaced, _3 Replacement 03 Yes

D 13 Repaired, 03 No 03 Replaced, _3 Replacement 03 Yes 0] Repaired, 03 No 03 Replaced, 03 Replacement 03 Yes

F 03 Repaired, 03 No 03 Replaced, __ Replaement 0] Yes

Page 1 of 2 Revision 5

Page 104: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Seal welded valve 2CF0188 body to bonnet

8. Test Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. IA Other 0 Exempt•l

Pressure _psig Test Temp. OF Pressure psig Test Temp. OF Pressure _psig Test Temp. OF

9. Remarks

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A

Signed ",, .,• , FL Grass Jr..QA Tech Specialist Date - 19 9jY Owner oi•Owner's Designee, Title

Page 2 of 2 Revision 5

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of. North Carolina and employed by HSBI and I Company of Hartford Connecticut bave inspected thI components described in this Owner's Report during the period L- to , and state that to the best of my knowledge and belief, the Owner has performed examinatiohs and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

S•(• (•P ~ V',.._Commissions KYR77o 9.,n 5 t n VS.e -.7" Inspector'd 8igurue- National Board, StAte, Province and rndorsements

Page 105: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S nmr'ORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner Address: Duke Power Company

526 S. Church Street, Charlotte, NC 28201-1006

2. Plant Address:

la. Date May20, 1999

Sheet 1 of 1

McGuire Nuclear Station

12700 Haggers Ferry Road, Huntersville, NC 28078

2a. Unit: 01 1•2 03 r3Shared (specify Units

3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A

4. (a) Identification of System: NV - Chemical and Volume Control 4. (b)

5. (a) Applicable Construction Code: ASME III 19L1 Edition, Summer and Winter Addenda, (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989, No Addenda

6. Identification of Components Repaired or Replaced and Replacement Components:

3a. Work Order #:

3b. NSM or MM #:

98024727 Repi OrMazone Job #

N/A

Class of System: B

N/A Code Cases

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Repaired, Replaced, or ASME Code Stamped

Replacement (yes or no)

A 03 Repaired, 03 No

2NV0124 Fisher 5921347 741 N/A 1975 O3Replaced, ,.__ _Replacement EYes

B 0 Repaired, 03 No

03 Replaced, _ __Replacement O3Yes

C [0 Repaired, 03 No 0 Replaced,

__3 [] Replacement 03 Yes D 10 Repaired, 0 No

0] Replaced,

[0 Replacement 0 Yes E 13 Repaired, 01 No

0 Replaced, _3 Replacement 03 Yes

LI- riepa'•,J ,'LI I'IOri--tigpalredo, 0 Replaced,

0 Replacement 0 Yes

Page 1 of2 Revision 5

F

Page 106: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replaced Plug

8. Test Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. l0 Other 51 Exempts

Pressure _psig Test Temp. OF Pressure psig Test Temp. OF Pressure psig Test Temp. -OF

9. Remarks

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A

Signed FL Grass Jr.,QA Tech Specialist Date t.w, 19 iL Owner orOwne's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have inspected the components described in this Owners Report during the period 3 a! to 5"-94 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Nationa oard Commissions M-7-7 a2? M)and3. N -7m Inspector's Signatdr) - National Board, Stale, Province and Enaorsements

Page 2 of 2 Revision 5

Date 1~2 I 194

Page 107: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S F-iEPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Secton X1

1. Owner Address: Duke Power Company

526 S. Church Street, Charlotte, NC 28201-1006

2. Plant Address:

la. Date April 29, 1999 Sheet 1 of 1

McGuire Nuclear Station

12700 Hagers Ferry Road, Huntersville, NC 28078

2a. Unit: 01 E12 103 []Shared (specify Units

3. Work Performed By: Duke Power Company 3a. Work Order #:

Address: 526 S. Church Street, Charlotte NC 28201-1006

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A

4. (a) Identification of System: NV - Chemical and Volume Control 4. (b)

5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda,

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989, No Addenda

6. Identification of Components Repaired or Replaced and Replacement Components:

3b. NSM or MM #:

Class of System: B N/A

98024747 R•er Organiz&oi Jolb#

N/A

Code Cases

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8

Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Repaired, Replaced, or ASME Code Stamped Replacement (yes or no)

A 0 Repaired, 03 No

2NV-1 1 Walworth 2318SP A0598 N/A 1973 0 Replaced, ElReplacement 0Yes

B 0 Repaired, 03 No O3 Replaced, 1o Replacement 03 Yes

C [0 Repaired, [3 No o3 Replaced, Eo Replacement E3 Yes rI ;I-A I,-

0 Replaced, 0] Reolacement 03 Yes

_________________la e * I ..0 Repaired, O Replaced, 0 Replacement

4 1 I I � I LI fl�p�II�U, LI PIV

0 Replaced, O ReDlacement

13 Yes

0] YesII I__ _ __ _ _ .- I7L_ __ _ _

Page 1 of 2 Revision 5

E

F

N/A

Page 108: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of WorkPin neiorlo hrnnnatt hnlf,- annt f M "U~% ,rjS ,JL, A 0 L.

8. Test Conducted:Hydrostatic 0 Pneumatic El Nom. Operating Press.

9. Remarks

Z] Other El Exempt[]

Pressure psig Test Temp. _ F Pressure psig Test Temp. OF Pressure psig Test Temp. OF

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A

Signed N• C4/- FL Grass Jr.,QA Tech Specialist Date 19 2Ownetror Owner's Designee, Title

Page 2 of 2 Revision 5

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut haveinspected the mponents described in this Owner's Report during the period ..- "- to -TZ-!=1; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions A) 7 •A! S ' J Inspectors Si _ l National Board, State, Province and Endorsements

Date

Page 109: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S r-PORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xi

1. Owner Address: Duke Power Company

526 S. Church Street. Charlotte, NC 28201-1006

2. Plant Address:

la. Date May26.,1999

Sheet 1 of 1

McGuire Nuclear Station,

12700 Hapers Ferry Road, Huntersville, NC 28078

2a. Unit: 01 219 1-3 OShared (specify Units

3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A

4. (a) Identification of System: CF- Feedwater

5. (a) Applicable Construction Code: ASME IIl 1971 Edition, Summer and Winter Addenda, (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1989, No Addenda

6. Identification of Components Repaired or Replaced and Replacement Components:

3a. Work Order #:

3b. NSM or MM #:

4. (b) Class of System: B

N/A

98025055 Repair Organizaion Job#

N/A

Code Cases

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Repaired, Replaced, or ASME Code Stamped

Replacement (yes or no)

A 03 Repaired, 03 No 2CF-0190 Kerotest DAN1-8 31242 N/A 1980 03 Replaced,

I EIReplacement IBYes B 0 Repaired, E3 No

0 Replaced, 10 Replacement 03 Yes

C 0 Repaired, 03 No 0 Replaced, _0 Replacement 0 Yes

D 0 Repaired, 0 No 0 Replaced,

[0 Replacement 03 Yes

E 0 Repaired, 0 No 0 Replaced, 0 Replacement 03 Yes

F 0 Repaired, 0 No 0 Replaced,

__ Replacement 0 Yes

Page 1 of 2 Revision 5

Page 110: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Seal welded Body to bonnet

8. Test Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. Rl Other [] Exemptl

Pressure _psig Test Temp. O__ _F Pressure psig Test Temp. OF Pressure _psig Test Temp. OF

9. Remarks

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A

Signed ,M/_ FL Grass Jr.,QA Tech Specialist Date ,z•/Z1 19_._2 "bwner o )•ner's Designee, Titoe

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticu have inspected the components described in this Owners Report during the period 3---.-Rq to S and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

totur Commissions AY1V7-WA J~ iC-~ On /J 17T ate 9r Ia~onal Board, State, Province andEndorsements Date

Page 2 of 2 Revision 5

Page 111: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner Address:

2. Plant Address:

Duke Power Company

526 S. Church Street, Charlotte, NC 28201-1006

McGuire Nuclear Station

12700 Hagers Ferry Road, Huntersville, NC 28078

Ia. Date 4/1/99

Sheet 1 of I

2a. Unit: [I 1 ] 2 [- 3 E] Shared (specify units)

3. Work Performed By: Duke Power Company

Address: 526 S. Church Street, Charlotte, NC 28201-1006

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A

(a) Identification of System: NV 4. (t

(a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda,

Applicable Edition of Section XI Utilizing for Repairs or Replacements: 1989, No Addenda

Identification of Components Repaired or Replaced and Replacement Components:

3a. Work Order # 98043826 Repair Organization Job #

3b. NSM or MM # N/A

) Class of System: B

NO Code Cases

Column 1 Column 2 Column 3 Column 4 Column 5 Col. 6 Column 7 Column 8 Repaired, Replaced, or ASME Code

Name of Component Name of Mfg. Mfg. Serial No. National Board No. Other Identification Year Built Replacement Stamped (yes or no) __________________Repair et tmeddyes N o ro

A Hanger DUKE POWER CO NA NA LOAD PIN NA E3 Repaired, 0 No 0 Replaced,

2-MCR-NV-4483 3/8" DIA [] Replacement 0 Yes

B HANGER DUKE POWER CO NA NA LOAD PIN NA 0 Repaired, 0 No 0 Replaced,

2-MCR-NV-4483 3/8" DIA 0 Replacement E0 Yes C ] Repaired, 0 No o[ Replaced,

[3 Replacement E3 Yes D 0 Repaired,' 0 No

[o Replaced, EO Replacement " [ Yes

o] Repaired, 0 No E E Replaced,

[o Replacement 0 Yes [] Repaired, 0 No

F [3 Replaced, E3 Replacement 0 Yes

Page I of 2 Revixion 5

4.

5.

(b)

6.

Page 112: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS -2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used , provided (1) size is 8 1/2 in. x 11 in. (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of work : Replaced load pin

8. Test Conducted : Hydrostatic [] Pneumatic 0 Nom. Operating Press. [I Other [I Exempt 0

Pressure Pressure Pressure

psig psig psig

Test Temp

Test Temp

Test Temp

OF

OF OF

9. Remarks : No testing required, snubber operability was not affected

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of North Carolina and employed by HSBI and I Company of Hartford Connecticut have inspected the components described in this Owner's Report during the period --- [ to.1-&.1." L ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Inspector' Signature

Date 1'6 ,1s_

Commissions . 77,,,S J -IZ National Board, State, Providence and Endorsements

CERTIFICATE OF COMPLIANCE We certify that he statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed A4WI'Vla ./?!16:WV• , '-Date 4/1 19 99

Ownei or Owner's Designee,"litle

Pape 2 of 2 Revision 5

Page 113: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner Address:

2. Plant Address:

Duke Power Company

526 S. Church Street, Charlotte, NC 28201-1006

McGuire Nuclear Station

12700 Hagers Fry Road, Huntersville, NC 28078

Ia. Date 4/28/99

Sheet 1 of

Unit: []1 ] 2 [] 3 [] Shared (specify units)

Work Performed By: Duke Power Company 3a. Work Order 4

Address: 526 S. Church Street, Charlotte, NC 28201-1006

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 3b. NSM or MM

(a) Identification of System: CA 4. (b) Class of System: B

(a) Applicable Construction Code: ASME 1111971 Edition, Summer and Winter Addenda, NO Code Cases

Applicable Edition of Section XI Utilizing for Repairs or Replacements: 1989, No Addenda

Identification of Components Repaired or Replaced and Replacement Components:

98043826 Repair Organization Job #

# N/A

Page I of 2 Revision 5

2a.

3.

4.

5.

(b)

6.

Column 1 Column 2 Column 3 Column 4 Column 5 Col. 6 Column 7 Column 8 Repaired, Replaced, or ASME Code

Name of Component Name of Mfg. Mfg. Serial No. National Board No. Other Identification Year Built Replacement Stamped (yes or no)

A Hanger DUKE POWER CO NA NA LOAD PIN NA '] Repaired, 0 No 0 Replaced,

2-MCA-CA-H089 3/4" DIA [3 Replacement 0l Yes

B HANGER DUKE POWER CO NA NA LOAD PIN NA [3 Repaired, 0 No [3 Replaced,

2-MCA-CA-H089 3/4" DIA [] Replacement [3 Yes O[ Repaired, 0l No

C [3 Replaced,

1 o Replacement 0l Yes O[ Repaired, 0l No

D 0l Replaced, [o Replacement 0l Yes 0 Repaired, 0l No

E [3 Replaced, 1 [3 Replacement El Yes

O Repaired, 0l No F E Replaced, )

I r-_ Replacement 0l Yes

Page 114: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS -2 (Back) NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used , provided (1) size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of work: Replaced load pin

8. Test Conducted : Hydrostatic 0 Pneumatic 0 Nom. Operating Press. 0 Other 0 Exempt 0

Pressure psig Test Temp OF Pressure psig Test Temp OF Pressure psig Test Temp OF

9. Remarks : No testing required, snubber operability was not affected

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that he statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorizatio J/o. N/A Expiration Date N/A Signed / L el•' /Ž' (" "•1 ý5'i#•C'41 5 'Date 4/28 19 99

Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of North Carolina and employed by HSBI and I Company ofHartford onncticut havei spc the components described in this Owner's Report during the d ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions /) 7 A ' ?• / ) .K InD tor'-Signature National Board, State, Providence and Endorsernents Date - 6 , 1929

Page 2 o"2 Revision 5

Page 115: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S htM-ORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner Address:

2. Plant Address:

la. Date May 20, 1999

Sheet 1 of 1

Duke Power Company

526 S. Church Street, Charlotte, NC 28201-1006

McGuire Nuclear Station

12700 Ha-ers Ferry Road, Huntersville, NC 28078

2a. Unit: 01 12 03 O3Shared (specify Units . _.

3. Work Performed By: Duke Power Company 3a. Work Order #: 98071681 Address: 526 S. Church Street, Charlotte NC 28201-1006 Regr OWaion Job

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 3b. NSM or MM #: MGMM104

4. (a) Identification of System: RV - Containment Ventilation Cooling Water 4. (b) Class of System: B

5. (a) Applicable Construction Code: ASME III 19Z1 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1989, No Addenda

6. Identification of Components Repaired or Replaced and Replacement Components:

.05

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Seda] No. National Board No. Other Identification Year Built Repaired, Replaced, or ASME Code Stamped

Replacement (yes or no) A 13 Repaired, 03 No

RV Piping Duke Power N/A 72 N/A 1982 OReplaced, _ Replacement ElYes

B 03 Repaired, 13 No o3 Replaced, _Replacement OYes

C 0 Repaired, 03 No El Replaced, 1o Replacement El Yes

D 0 Repaired, 13 No El Replaced, E3 Replacement 0 Yes 03 Repaired, 13 No El Replaced, EO Replacement El Yes

-In Q I I u

"0 Replaced, "0 Replacement 13 Yes

Page 1 of 2 Revision 5

Page 116: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replaced bolting in flange at Valve 2RV32A.

8. Test Conducted:Hydrostatic [] Pneumatic 0 Nom. Operating Press. 01 Other 0 Exempt[

Pressure psig Test Temp. -OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A

Signed ,, FL Grass Jr..QA Tech Specialist Date 19 19 Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have in p~cted the components described in this Owners Report during the pedod -4 toS"-J.--'q and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

nso r NaCommissions aO BIor S1Z tA en, o in) a1 Inspefto s Hrgn~iture National Board, State,'Province and 1fridorsernents

Page 2 of 2 Revision 5

Date . 19

Page 117: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section X!

1. Owner Address:

2. Plant Address:

2a. Unit: E1 02

1a. Date May 20, 1999

Sheet 1 of 1Duke Power Company

526 S. Church Street, Charlotte, NC 28201-1006

McGuire Nuclear Station

12700 Haaers Ferry Road, Huntersville. NC 28078

03 O-Shared (specify Units

3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201 -1006

Type Code Symbol Stamp: N/.A Authorization No. N/A Expiration Date: N/A

4. (a) Identification of System: RV - Containment Ventilation Cooling Water

3a. Work Order # :

3b. NSM or MM #:

4. (b) Class of System: B

5. (a) Applicable Construction Code: ASME 1II 1971 Edition, Summer and Winter Addenda, (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989, No Addenda

6. Identification of Components Repaired or Replaced and Replacement Components:

N/A Code Cases

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Repaired, Replaced, or ASME Code Stamped

Replacement (yes or no) A 13 Repaired, 0 No

RV Piping Duke Power N/A 72 N/A 1982 O3Replaced, __Replacement I0Yes

B 03 Repaired, 03 No o3 Replaced,

[]Replacement DYes C 03 Repaired, 0 No

o Replaced,

13 Replacement 0 Yes D 0 Repaired, 0 No

0 Replaced, _0 Replacement 0 Yes

E 0 Repaired, 0 No 0 Replaced,

_0 Replacement 03 Yes

RI epaired, 03 Replaced, 03 Replacement

0YNO

13 Yes

Page l of2 Revision 5

98071683Replr OqwaizaWlon Jcb#

MGMM1 0405

F

Page 118: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replaced bolting in flange at Valve 2RV33B.

8. Test Conducted:Hydrostatic El Pneumatic El Nom. Operating Press. El Other El Exempto

Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure _psig Test Temp. OF

9. Remarks

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section X1.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A

Signed FL Grass Jr.,QA Tech Specialist Date 19 .;Eo1

"Owner c1 Owner's Designee, Title

Page 2 of 2 Revision 5

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have ins•ected the components described in this Owner's Report during the period 3A:2ýS% to §ý"---9 : and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

n'po aCommissions M '77• , L7,3C ) J -- ? nspec or sNational Board, State, Province and Endorsements

Date 1 9_j

Page 119: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section X1

1. Owner Address:

2. Plant Address:

Duke Power Company

526 S. Church Street, Charlotte, NC 28201-1006

McGuire Nuclear Station

1 a. Date May 20, 1999

Sheet 1 of 1

12700 Hagers Ferry Road, Huntersville, NC 28078

2a. Unit: 01 02 03 OShared (specify Units

3. Work Performed By: Duke Power Company Address: 526 S, Church Street, Charlotte NC 28201-1006

Type Code Symbol Stamp: N/_A Authorization No. N/A Expiration Date: N/A

4. (a) Identification of System: RV - Containment Ventilation Cooling Water

3a. Work Order#:

3b. NSM or MM #:

98071686 Repair OMwkellw Job #

MGMM10405

4. (b) Class of System: B

5. (a) Applicable Construction Code: ASME 1II 1971 Edition, Summer and Winter Addenda, (b) Applicable Edition of Section Xi Utilized for Repairs or Replacements: 1989, No Addenda

6. Identification of Components Repaired or Replaced and Replacement Components:

N/A Code Cases

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Repaired, Replaced, or ASME Code Stamped

Replacement (yes or no) A E3 Repaired, 03 No

RV Piping Duke Power N/A 72 N/A 1982 nReplaced, .__ _ _ _I .Replacement OYes

B 03 Repaired, 03 No 03 Replaced, nReplacement DYes

C 0 Repaired, 0 No o Replaced, O Replacement 0 Yes

D 0 Repaired, 0 No 0 Replaced, 0 Replacement 03 Yes

E 0 Repaired, 0 No o Replaced, [0 Replacement 03 Yes

R -epaired, 03 Replaced, 03 Replacement

U NO

0 Yes

Page 1 of2 Revision 5

F

Page 120: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replaced bolting in flange at Valve 2RV76A.

8. Test Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. IA Other 0 Exempt[

Pressure psig Test Temp. OF Pressure __ _psig Test Temp. OF Pressure _psig Test Temp. OF

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A

Signed \,• _ FL Grass Jr..QA Tech Specialist Date .Ž•-Q, 19 99_ Owner or Owners Designee, ride

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have ins ed the components described in this Owners Report during the period 9to , and state that to the best of my knowledge and belief, the Owner has performdd examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section X1. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

'Jrg~ture Commissions -177W ,M SS tJ --T InsPctors &gtkturG National Board, State, Province andFEndorsements

Page 2 of 2 Revision 5

Date 1.9(1

Page 121: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xl

1. Owner Address: Duke Power Company

526 S. Church Street. Charlotte, NC 28201-1006

2. Plant Address:

la. Date May 20, 1999

Sheet 1 of I

McGuire Nuclear Station

12700 Hagers Ferry Road. Huntersville. NC 28078

2a. Unit: 01 E12 03 OShared (specify Units

3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006

Type Code Symbol Stamp: N/.A Authorization No. N/A Expiration Date: N/A

3a. Work Order#:

3b. NSM orMM

98071687Reer Organiai Job#

PAt_-A AA,4 A A.r

4. (a) Identification of System: RV - Containment Ventilation Cooling Water 4. (b)

5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, _ (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1989. No Addenda

Class of System: B

N/A

6. Identification of Components Repaired or Replaced and Replacement Components:

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Repaired, Replaced, or ASME Code Stamped

Replacement (yes or no)

A 03 Repaired, 03 No RV Piping Duke Power N/A 72 N/A 1982 OReplaced,

"I _Replacement EYes 0E Repaired, 03 No 03 Replaced,

OReplacement OYes C 03 Repaired, 0 No

o3 Replaced,

E0 Replacement 03 Yes D 0 Repaired, 0 No

0 Replaced, 13 Replacement 03 Yes

E 0 Repaired, 0 No 0 Replaced, 1_ Replacement 0 Yes

"LI Repaired, "0 Replaced, 0 Replacement

LI No

0 Yes

Page 1 of 2 Revision 5

Code Cases

F

0

Page 122: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in items1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replaced bolting in flange at Valve 2RV77B.

8. Test Conducted:Hydrostatic 0] Pneumatic 0 Nom. Operating Press. IA Other 0 Exempt[]

Pressure psig Test Temp. OF Pressure psig Test Temp. F__ F Pressure _psig Test Temp. OF

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A

Signed \ FL Grass Jr..QA Tech Specialist Date .S-,' 19 .2_ "Owner of'Owner's Designee, Tite

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have inspected the components described in this Owner's Report during the period -'o -j to" and state that to the best of my knowledge and belief, the Owner has performed examinations find taken corrective measures described in this Owners Report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or pro rt damage or a loss of any kind arising from or connected with this inspection.

-- _ _ __ Commissions 0- '7T7 9 W ',- A) -. 7 Inspector's S gnatufeo National Board, State, Province and Endorsements

Page 2 of 2 Revision 5

Date l

Page 123: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner Address:

2. Plant Address:

2a.

3.

1 a. Date 09-23-00

Sheet 1 of I

Duke Power Company

526 S. Church Street, Charlotte, NC 28201-1006

Mcguire Nuclear Station

12700 Hagers Ferry Road, Huntersville, NC 28078

Unit: El1 2 2 [] 3 El Shared (specify units)

Work Performed By: Duke Power Companv 3a. Work Order # 98071897-08 Repair Organization Job #

Address: 526 S. Church Street, Charlotte, NC 28201-1006

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 3b. NSM or MM# MGMM10177

4. (a) Identification of System: FW REFUELING WATER 4. (b) Class of System: B

5. (a) Applicable Construction Code: ASME m 1971 Edition, Summer and Winter Addenda, N-416-1 Code Cases

(b) Applicable Edition of Section XI Utilizing for Repairs or Replacements: 1989, No Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)

6. Identification of Components Repaired or Replaced and Replacement Components:

Page I of 2 Revision 7

Column 1 Column 2 Column 3 Column 4 Column 5 Col. 6 Column 7 Column 8 Repaired, Replaced, or ASME Code Name of Component Name of Mfg. Mfg. Serial No. National Board No. Other Identification Year Built Replacement Stamped C(es or no)

0] Repaired, 0] No A VALVE 2FW 009 WALWORTH A1116 316 2FW 1974 [3 Replaced,

[3 Replacement 0 Yes 0] Repaired, 0] No

B VALVE 2FW 075 ITT GRINNELL 80-52815-1-8 WR6321 2FW 1980 [3 Replaced,

________________ ___________[3 Replacemet, e 0 Replacement 0 Yes

C PIPING DUKE POWER N/A 54 2FW 1982 [] Repaired, 0 No [3 Replaced,

M] Replacement 0 Yes [I Repaired,. 0 No

D [ Replaced, [3 Replacement [3 Yes [0 Repaired, E3 No

E [ Replaced, ----- 1-[o Replacement [3 Yes

E3 Repaired, [3 No F 0 Replaced,

[o Replacement 0 Yes

Page 124: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS -2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of work: DELETED VALVE 2FW 009 & INSTALL VALVE

2FW 75 & PIPING

8. Test Conducted : Hydrostatic D Pneumatic D Nom. Operating Press. 0 Other 0 Exempt 0

Pressure HEAD psig Test Temp 81.9 OF Pressure psig Test Temp OF Pressure psig Test Temp OF

9. Remarks:

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that he statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed E. P. Robinson Exec. Supp. 0, Date 09-28 20 00

Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut h veinspected the components described in this Owner's Report during the period _ to, 8-111M ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

R. D. Klein S Commissions NB7728, NC853, N-I Inspector s~ National Board, State, Province and Endorsements

Date f-, .• , 20 C)(2>

Page 2 of 2 Revision 7

Page 125: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section X1

1. Owner Address: Duke Power Company

526 S. Church Street, Charlotte, NC 28201-1006

2. Plant Address:

la. Date May 25, 1999

Sheet 1 of 1

McGuire Nuclear Station

12700 Hagers Ferry Road, Huntersville, NC 28078

2a. Unit: 01 I02 03 OShared (specify Units

3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/._A Expiration Date: N/A

4. (a) Identification of System: SM - Main Steam

5. (a) Applicable Construction Code: ASME Il 1971 Edition, Summer and Winter Addenda, (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1989, No Addenda

6. Identification of Components Repaired or Replaced and Replacement Components:

3a. Work Order #:

3b. NSM or MM #:

4. (b) Class of System: B

N/A

98090072 Repat OrWizubw Jcb#

N/A

Code Cases

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Repaired, Replaced, or ASME Code Stamped

Replacement (yes or no) A 0 Repaired, 03 No

2SM-0101 Kerotest TM5-5 12302 N/A 1996 OReplaced, __Replacement 0Yes

B 13 Repaired, 03 No o3 Replaced, [0Replacement DYes

C 13 Repaired, 03 No

03 Replaced, _ Replacement 03 Yes

D 10 Repaired, 0 No 0 Replaced, 10 Replacement 0] Yes

E E0 Repaired, 0 No 0 Replaced,

_3 Replacement 0 Yes

u Repaired, 03 Replaced, 03 Replacement

Li NO

0 Yes

Page 1 of 2 Revision 5

F

Page 126: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in items1l through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replaced Disc

8. Test Conducted:Hydrostatic Li Pneumatic EJ Nom. Operating Press. Rl Other El ExemptEi

Pressure _psig Test Temp. OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF

9. Remarks

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section X1.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A

Signed !;.aog6/ FL Grass Jr.,QA Tech Specialist Date 19 9q Owner lOwner's Designee, Title

Page 2 of 2 Revision 5

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have inspected the components described in this Owners Report during the period 3-0--qt to ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissionsar Inspector's i nre National Board, State, Province and Endorsements

DateJS VA6 19T

Page 127: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

2. Plant Address:

-....... V wei %mrnpany

526 S. Church Street, Charlotte. NC 28201-1006

Mcguire Nuclear Station

12700 Hagers Ferry Road, Huntersville, NC 28078

Ia. Date 10-01-00

Sheet 1 of I

2a. Unit: [-1 ] 2 [1 3 El Shared (specify units)

3. Work Performed By: Duke Power Company 3a. Work Order # 98098695-58

Address: 526 S. Church Street. Charlotte. NC 28201-1006 Repi orgn.nti, Job

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 3b. NSM or MM # 22509

4. (a) Identification of System: NI (SAFETY INJECTION) 4. (b) Class of System: B

5. (a) Applicable Construction Code: ASME I 1921 Edition, Summer and Winter Addenda, N-416-1 Code Cases

(b) Applicable Edition of Section XI Utilizing for Repairs or Replacements: 1989, No Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)

6. Identification of Components Repaired or Replaced and Replacement Components:

.. . Column 1 Column 2 Column 3 Column 4 Column 5 Col. 6 Column 7 Column 8 Repaired, Replaced, or ASME Code Name of Component Name of Mfg. Mfg. Serial No. National Board No. Other Identification Year Built Replacement Stamped (yes or no)

A 2NI VALVE 9A WALWORTH C54751 2 NI 1973 [0 Repaired, 03 No 0 Replaced,

_..... ......... .C3 Replacement 0 Yes

B 2NI VALVE 9A BWIP E492A-l-3 2102 NI 1998 [0 Repaired, 0 No [3 Replaced,

S........ .0 Replacement 0 Yes C 0 Repaired, 0 No

[3 Replaced, I...... ... [I Replacement [0 Yes

D [o Repaired, 0 No D-0 Replaced,

__........___0 Replacement 0 Yes E [0 Repaired, 0 No E3 Replaced,

S•.___ Replacement 0 Yes F [o Repaired, [3 No F0 Replaced,

0O Replacement 0 Yes

Page I of 2 Revision 7

3

.0 < Z c r '

\ __u~ r'0A-]

Page 128: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES. 7 As Required by the Provisions of the ASME Code, Section III, Division 1 e ,

Pg. of

"8W/IP International, Inc. Valve Division -- eet

1. Manufactured and certified by 701 First Street, Williamsport, PA. 17701 jname and address of N Certificate Holder)

2. Manufacturedfor Duke Energy Corporati.on P.O. Box 1015, Charlotte, NC. 28201-115 (name a address of Puechasee) 2........ .... 8-89"

McGuire Nuclear Site, 13225 Hagers Ferry Rd. Highway 73, Huntersville, NC. 3. Location of installation Iname and address

Flex Wedge Gate W9825122 Rev. B _ N/A t. Model No.. Series No.. or Type Drawing Rev. CRN_

;. ASME Code, Section Wit, Division 1: 1989 1990 2 N/A leditiont (addenda datel (classl (Code Case no.) Va 1ve 4 4

Pump or valve Valve Nominal inlet size -- Outlet size (in.) (in.)

Material: Body SA351-CF8M Bonnet SA_82-F316 Disk SA351-CFBM g• . NIA

(a) Cert.

Holder's

Serial No.

'92A-1-3 .92A-l-4

1b) Nat'l

Board

No.

NB# 2102 NB# 2103

Ic) Body Serial No.

Y1172 Y1174

(d) Bonnet

Serial No.

3 4

(el Disk

Serial No.

3

emental information in form of lists. sketches, or dcawings may be used provided (II size is 8 % x 11, (2) information in items I through 4

a Data Report is included on each sheet. (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form I00037) may be obtained from the Order Dept.. ASME. 22 Law Drive. Box 2300. Fairfield, NJ 07007-2300. 1EPFI.4T 693

12 ,,7

Page 129: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner Address:

2. Plant Address:

la. Date 05/20/99

Sheet 1 of 1Duke Power Company

526 S. Church Street. Charlotte, NC 28201-1006

Mcguire Nuclear Station

12700 Hagers Ferr Road, Huntersville. NC 28078

2a. Unit: F] 1 0 2 0l 3 E] Shared (specify units)

3. Work Performed By: Duke Power Company 3a. Work Order A

Address: 526 S. Church Street. Charlotte, NC 28201-1006

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 3b. NSM or MM

4. (a) Identification of System: NV 4. (b) Class of System: B

5. (a) Applicable Construction Code: ASME MI 1921 Edition, Summer and Winter Addenda, N/A Code Cases

(b) Applicable Edition of Section XI Utilizing for Repairs or Replacements: 1989, No Addenda

6. Identification of Components Repaired or Replaced and Replacement Components:

98103158 Repair Organization lob#

# N/A

Column 1 Column 2 Column 3 Column 4 Column 5 Col. 6 Column 7 Column 8 Repaired, Replaced, or ASME Code

Name of Component Name of Mfg. Mfg. Serial No. National Board No. Other Identification Year Built Replacement Stamped (yes or no) 198 Repaired, 0 No

A VALVE DRESSER TE09057 415 2NV-486 1978 0 Repaed, [] Replaced,

__ Replacement M Yes

o3 Repaired, [3 No B 0 Replaced,

[o Replacement 0 Yes [I Repaired, 0 No

C 0 Replaced, 0] Replacement 0 Yes [o Repaired, 0 No

D 0 Replaced, _ _ Replacement _0 Yes o Repaired, 0 No

E 0 Replaced, 0 Replacement 0 Yes

o Repaired, 0 No

F 0 Replaced, o Replacement 0 Yes

Page I of 2 Revision 5

Page 130: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS -2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of work: REPLACED DISC

8. Test Conducted : Hydrostatic 0 Pneumatic [0

Pressure Pressure Pressure

,psig

psig psig

Nonm Operating Press. 0 Other 0 Exempt 0

Test Temp Test Temp Test Temp

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that he statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed F.R. Sorrow Exec. Supp. y Date 05/20 19 99

Owner or Owner's D•signee, Title

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of North Carolina and employed by HSBI and I Company of Hartford Connecticut have ins pcted the components described in this Owner's Report during the period -,b to'; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

R. D. Klein QU Inspector's Sign ure

Date I , 19-9_1

Commissions NB7728, NC853, N-I National Board, State, Province and Endorsements

Page 2 of 2 Revision 5

9. Remarks :

OF OF OF

Page 131: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xl

1. Owner Address:

2. Plant Address:

I a. Date July 6. 2000 Sheet 1 of 1

Duke Power Company

526 S. Church Street, Charlotte, NC 28201-1006

McGuire Nuclear Station

12700 Hagers Ferry Road, Huntersville, NC 28078

2a. Unit: 01 212 03 O-Shared (specify Units )

3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A

4. (a) Identification of System: NV - Chemical and Volume Control

3a. Work Order #:

3b. NSM or MM #:

98107296 Re~r Orgkafion Job*

N/A

4. (b) Class of System: B

5. (a) Applicable Construction Code: ASMEIII 1971 Edition, Summer and Winter Addenda, N/A Code Cases

(b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1989, No Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)

6. Identification of Components Repaired or Replaced and Replacement Components:

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Repaired, Replaced, or ASME Code Stamped

Replacement s or no) A 10 Repaired, 03 No

2NV-265 Kerotest DG5-1 1 5879 N/A 1981 03 Replaced, iReplacement WYes

B 03 Repaired, 0 No 03 Replaced, [0 Replacement 0 Yes

0 Repaired, 03 No 0 Replaced,

_3 Replacement 0 Yes

D 0 Repaired, 03 No 03 Replaced, _0 Replacement 0 Yes

E 03 Repaired, 03 No 03 Replaced, 0 Replacement 0 Yes

F 0 Repaired, 0 No 03 Replaced,

__ Replacement 0 Yes

Page 1 of2 Revision 6

Page 132: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of WorkRim ntlsOHrld icr

8. Test Conductedl--Hydrostatic 0 Pneumatic 0 Nom. Operating Press. AOther 0 Exempto

9. Remarks

Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure -psig Test Temp. OF

(Applicable Manufacturers Data Records.to be attached)

CER7IFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A

Signed .i,-. ) FL Grass Jr.. QA Tech Specialist Date 7 / , '

Owner o(Owners Designee, Title

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have inspected the components described in this Owners Report during the period Yt- to 4•-L 1, and state that to the best of my knowledge and belief, the Owner has p4drirel examinations and taken corrective measures described in this Owners Report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in the Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

- '_4 t ,- R.D. Klein Inspec nature

Date ao

Commissions NB7728, NC853, N-I National Board, State, Province and Endorsements

Page 2 of 2 Revision 6

R•nln•rl rlic=n

Page 133: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner Address: Duke Power Company

526 S. Church Street, Charlotte, NC 28201-1006

2. Plant Address:

la. Date May25. 1999

Sheet 1 of 1

McGuire Nuclear Station

12700 Hagers Ferry Road, Huntersville, NC 28078

2a. Unit: 01 02 03 []Shared (specify Units

3. Work Performed By: Duke Power Company Address: 526 S. Church Street. Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A

4. (a) Identification of System: ND - Residual Heat Removal

3a. Work Order #:

3b. NSM or MM #:

98122733 Repair Owanizaion Job#

N/A

4. (b) Class of System: B

5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1989, No Addenda

6. Identification of Components Repaired or Replaced and Replacement Components:

N/A Code Cases

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Repaired, Replaced, or ASME Code Stamped

Replacement (yes or no) A 10 Repaired, 03 No

2ND-0008 Borg - Warner 4625 39 N/A 1975 03 Replaced, _ _...._IOReplacement 0Yes

B 03 Repaired, 03 No 03 Replaced, E3 Replacement 03 Yes

03 Repaired, 03 No 03 Replaced, 03 Replacement 03 Yes

D 13 Repaired, 03 No 03 Replaced, _0 Replacement 03 Yes 03 Repaired, 03 No 03 Replaced, _0 Replacement 03 Yes 0 0 Repaired, 03 No 03 Replaced, _0 Replacement 0 Yes

Page 1 of 2 Revision 5

Page 134: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replaced Disc Assembly

8. Test Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. El Other I] Exempti

Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF

9. Remarks

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A

Signed Lý& Q FL Grass Jr.,QA Tech Specialist Date -5 4, 19 •' Owner d(Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have inspectedth components described in this Owners Report during the period t ( to" ---c,: and state that to the best of my knowledge and belief, the Owner has performned examinatiob's and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

-•Commissions "77 A -i Inspei•t r SComminjure National Board, State, Province and Endorsements

Page 2 of 2 Revision 5

Date 1W1 9_._1

Page 135: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S h,-r-ORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xl

1. Owner Address: Duke Power Company

526 S. Church Street, Charlotte, NC 28201-1006

2. Plant Address:

la. Date May 25,.1999 Sheet 1 of 1

McGuire Nuclear Station

12700 Haagers Ferry Road, Huntersville, NC 28078

2a. Unit: 01 212 03 OShared (specify Units

3. Work Performed By: Duke Power Company Address: 526 S. Church Street. Charlotte NC 28201-1006 Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A

4. (a) Identification of System: VI - Instrument Air

3a. Work Order #: 98142870Rep& Oraqazao Job #

3b. NSM or MM#: N/A

4. (b) Class of System: B

5. (a) Applicable Construction Code: ASME 1111971 Edition, Summer and Winter Addenda, (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989, No Addenda

6. Identification of Components Repaired or Replaced and Replacement Components:

N/A Code Cases

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Repaired, Replaced, or ASME Code Stamped

Replacement (yes or no)

A E3 Repaired, 03 No

2VI-0040 Kerotest S20-12 N/A N/A 1973 03 Replaced,

1 I•Replacement E[Yes

B 03 Repaired, 03 No O Replaced, 13 Replacement 03 Yes

-C 0 Repaired, 03 No [] Replaced,

o3 Replacement 03 Yes D O Repaired, 03 No

O3 Replaced,

1o Replacement 0 Yes

"El Replaced, "0 ReDlacement

I__ _ _ _ __ _. I i I U I'JIu iepalrea, "0 Replaced,

"0 Replacement

U YNe

13 Yes

0 Yes

Page 1 of 2 Revision 5

E

Page 136: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replaced Disc

8. Test Conducted:Hydrostatic 0 Pneumatic 51 Nom. Operating Press. I£ Other 0 ExemptE

Pressure _psig Test Temp. F__ F Pressure _psig Test Temp. _ F__F Pressure _psig Test Temp. OF

9. Remarks

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp NIA Certificate of Authorization No. N/A Expiration Date N/A

Signed -•- , FL Grass Jr.,QA Tech Specialist Date , ;• 19 I__j Owner opner's Designee, TtMee

Page 2 of 2 Revision 5

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have inspected the components described in this Owner's Report during the period •-•-' to ; and state that to the best of my knowledge and belief, the Owner has performed examinatiofs and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

______ ,__, _ Commissions FCB7• ., _, - /SJ- l Insaecto,.' S I , 1a.re National Board, State, Province and Endorsements

Date._. 1997

Page 137: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XA

1. Owner Address: Duke Power Company

526 S. Church Street, Charlotte, NC 28201-1006

2. Plant Address:

la. Date May20,1999 Sheet I of 1

McGuire Nuclear Station

12700 Haqers Ferry Road, Huntersville, NC 28078

2a. Unit: 01 1212 03 [Shared (specify Units

3. Work Performed By: Duke Power Company Address: 526 S. Church Street. Charlotte NC 28201-1006

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A

4. (a) Identification of System: NV - Chemical and Volume Control 4. (b)

5. (a) Applicable Construction Code: ASME 1111971 Edition, Summer and Winter Addenda,

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989, No Addenda

6. Identification of Components Repaired or Replaced and Replacement Components:

3a. Work Order #:

3b. NSM or MM #:

98143386 RqeptOrganizason Jab#

N/A

Class of System: B

NIA Code Cases

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Repaired, Replaced, or ASME Code Stamped

, Replacement (yes or no)

A 03 Repaired, 03 No 2NV238 Fisher 5921349 790 N/A 1976 E3Replaced,

1_EReplacement EYes

B 03 Repaired, 03 No 03 Replaced, [0Replacement WYes

C [0 Repaired, 03 No 0 Replaced, 03 Replacement 03 Yes

D 0 Repaired, 0 No [0 Replaced, 0 Replacement 03 Yes

E 0 Repaired, 0 No 0 Replaced, [0 Replacement 0 Yes 03 Repaired, 03 No"0 Replaced, "0 Replacement 01 Yes

Page I of 2 Revision 5

r

Page 138: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replaced Plug

8. Test Conducted:Hydrostatic El Pneumatic 0 Nom. Operating Press. IA(ther El Exempto

Pressure psig Test Temp. OF Pressure - psig Test Temp. OF Pressure _ _ psig Test Temp. OF

9. Remarks

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A

Signed -A FL Grass Jr.,QA Tech Spialist Date 19 Owner o(Owner's Designee, Tie

Page 2 of 2 Revision 5

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have insp eWted the components described in this Owners Report during the pedod- to . and state that to the best of my knowledge and belief, the Owner has performd examination' and taken corrective measures described in this Owners Report in accordance with the requirements of ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

tor N e 04Commissions '"717 , MC Y.3, /0 T Inspector'Signet0National Board, State,4 Province and Enddrsements

DateS

Page 139: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner Address: Duke Power Company

2. Plant Address:

526 S. Church Street, Charlotte, NC 28201-1006

McGuire Nuclear Station

Ia. Date July 6, 2000

Sheet 1 of 1

12700 Hacters Ferry Road, Huntersville, NC 28078

2a. Unit: 01 02 03 OShared (specify Units

3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A

4. (a) Identification of System: VI - Instrument Air

3a. Work Order #:

3b. NSM or MM #:

4. (b) Class of System: B

98145459 RepairOwantzadon Jcb#

N/A

5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989, No Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)

6. Identification of Components Repaired or Replaced and Replacement Components:

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Repaired, Replaced, or ASME Code Stamped

Replacement (yes or no)

A 13 Repaired, 03 No

2V1-124 Kerotest $20-9 N/A N/A 1973 03 Replaced, IReplacement WYes

B 03 Repaired, 0 No 0 Replaced, 03 Replacement 03 Yes

3 0 Repaired, 03 No 03 Replaced, _0 Replacement 03 Yes

D 0 Repaired, 0 No

0 Replaced, 3 0Replacement 03 Yes

E 0 Repaired, 03 No 0 Replaced, _0 Replacement 0 Yes 03 Repaired, 0 No 03 Replaced,

_0 Replacement 0 Yes

Page 1 of 2 Revision 6

Page 140: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replaced Disc

8. Test Conducted:Hydrostatic 0 Pneumatic EJ Nom. Operating Press. lBOther 0 ExemptO

Pressure psig Test Temp. °F Pressure psig Test Temp. OF Pressure psig Test Temp. OF

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A

Signed FL Grass Jr., QA Tech Specialist Date ____

"Owner orDwner's Designee, Tie

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have inspected the components described in this Owners Report during the period1: .. to "--J- . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

R.D. Klein Commissions NB7728. NC853, N-I " "gnata r National Board, State, Province and Endorsements

Date • 4~s ,

Page 2 of 2 Revision 6

Page 141: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner Address:

2. Plant Address:

la. Date 4/1/1999

Sheet 1 of I

Duke Power Company

526 S. Church Street, Charlotte, NC 28201-1006

McGuire Nuclear Station

12700 Hagers Ferry Road, Huntersville, NC 28078

2a. Unit: ] 1 Z 2 E] 3 [] Shared (specify units)

3. Work Performed By: Duke Power Company 3a. Work Order # 98146480 Repair Organization Job#

Address: 526 S. Church Street, Charlotte, NC 28201-1006

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 3b. NSM or MM # N/A

4. (a) Identification of System: NV 4. (b) Class of System: B

5. (a) Applicable Construction Code: ASME 11 1971 Edition, Summer and Winter Addenda, NO Code Cases

(b) Applicable Edition of Section XI Utilizing for Repairs or Replacements: 1989, No Addenda

6. Identification of Components Repaired or Replaced and Replacement Components:

Column I Column 2 Column 3 Column 4 Column 5 Col. 6 Column 7 Column 8 Repaired, Replaced, or ASME Code

Name of Component Name of Mfg. Mfg. Serial No. National Board No. Other Identification Year Built Replacement Stamped (yes or no) Hanger DUKE POWER CO NA NA LOAD PIN NA 0 Repaired, 0 No

g0 Replaced,

2-MCR-NV-4470 3/4" DIA 0[ Replacement 0 Yes 0] Repaired, [] No

B HANGER DUKE POWER CO NA NA LOAD PIN NA. [ Replaced,

2-MCR.NV-4470 3/4" DIA _0 Replacement 0 Yes 0[ Repaired, 0 No C0 Replaced, [O Replacement 0 Yes

0 Repaired, D No

D ]0 Replaced, 0] Replacement 0 Yes

o[ Repaired, 0 No E 0" Replaced,

""o Replacement 0 Yes o] Repaired, [0 No

F 0[ Replaced, 1 [o Replacement 10 Yes

Page I of 2 Revision 5

Page 142: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS -2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. -Description of work: Replaced load pin

8. Test Conducted : Hydrostatic [] Pneumatic 0 Nom. Operating Press. 0 Other [I Exempt 0

Pressure psig Pressure psig Pressure psig

Test Temp

Test Temp

Test Temp

OF

OF OF

9. Remarks : No testing required, snubber operability was not affected

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that he statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed A~ g Date 4/1 19 99 Owner or Owner's Design, ritde

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of North Carolina and employed by HSBI and I Company of Hartford Connecticut have inspected the components described in this Owner's Report during the peio to f, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Ins 's Signature

Date . _19 9

Commissions A¢1"A7e A1 r'i IV-YNational Board, State, Providence and Endorsements

Page 2 of 2 Revision 5

°

Page 143: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S RLPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Sectlon XI

1. Owner Address: Duke Power Company

526 S. Church Street, Charlotte, NC 28201-1006

2. Plant Address:

la. Date May27,1999

Sheet 1 of 1

McGuire Nuclear Station

12700 Haqers Ferry Road. Huntersville, NC 28078

2a. Unit: 01 122 03 OShared (specify Units

3. Work Performed By: Duke Power Company Address: 526 S, Church Street, Charlotte NC 28201-1006

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A

4. (a) Identification of System: NV - Chemical and Volume Control

3a. Work Order #:

3b. NSM or MM #:

98149341 RelIr OtrWgnlio, Job#

MGMM - 10952

4. (b) Class of System: B

5. (a) Applicable Construction Code: ASME III 19Z1 Edition, Summer and Winter Addenda, (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989, No Addenda

6. Identification of Components Repaired or Replaced and Replacement Components:

N/A Code Cases

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Repaired, Replaced, or ASME Code Stamped

Replacement (yes or no) A PSA 03 Repaired, []No

2MCA-S-NV-504-1- Duke Power 14183 N/A Mechanical N/A El Replaced, KK Snubber E3 Replacement 03 Yes

B Lisega 03 Repaired, EINo

2MCA-S-NV-504-1- Duke Power 61224-36 N/A Hydraulic N/A 03 Replaced, KK Snubber E]Replacement 0 Yes

03 Repaired, 03 No 0 Replaced, _0 Replacement 03 Yes

D 0 Repaired, 03 No 0 R3eplaced, _0 Replacement 0 Yes

E 13 Repaired, 03 No 0 Replaced,

_,__3 Replacement 03 Yes 0F Repaired, 0 No 0 Replaced, ]0 Replacement 0 Yes

Page 1 of 2 Revision 5

Page 144: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replaced PSA Mechanical Snubber with a Lisega Hydraulic Snubber

8. Test Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. Li Other 0 Exempto

Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure _psig Test Temp. OF

9. Remarks

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A

Signed .) FL Grass Jr..QA Tech Specialist Date 19_1 Owner or neer's Designee, Title

Page 2 of 2 Revision 5

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have inspected the components described in this Owner's Report during the period ,.-7--qto ."-,"9; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

In-spectr' ure Cmis ons l "ard, Ste, Province and'Endorsements

1 MDate

Page 145: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Sectaon XI

1. Owner Address: Duke Power Company

526 S. Church Street, Charlotte. NC 28201-1006

2. Plant Address:

la. Date July 15.1999 Sheet 1 of 1

McGuire Nuclear Station

12700 Haaqers Ferry Road, Huntersville, NC 28078

2a. Unit: 031 02 03 OShared (specify Units

3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A

3a. Work Order #:

3b. NSM or MM #:

98150360 Rtpeor Organizaoý Job #

N/A

4. (a) Identification of System: SM - Main Steam 4. (b) Class of System: B

5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases

(b) Applicable Edition of Section XA Utilized for Repairs or Replacements: 1989, No Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)

6. Identification of Components Repaired or Replaced and Replacement Components:

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Repaired, Replaced, or ASME Code Stamped

Replacement (yes or no) A 10 Repaired, I0No

2MCA-SM-H020 Duke Power 18871 N/A N/A N/A I[Replaced, O3 Replacement 0] Yes

B 03 Repaired, E[No

2MCA-SM-H020 Duke Power 21359 N/A N/A N/A 03 Replaced, _EIReplacement C0 Yes

C 0 Repaired, 0 No o3 Replaced, [] Replacement 0 Yes

D 0] Repaired, 0 No o Replaced, [] Replacement 0 Yes

E 0 Repaired, 0 No o Replaced, 1O Replacement 0 Yes

F 03 Repaired, 0] No O[ Replaced,

[O Replacement 0 Yes

Page 1 of2 Revision 6

Page 146: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replaced Snubber

8. Test Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. 0 Other 11 Exemptr-I

Pressure _ psig Test Temp. OF Pressure psig Test Temp. - OF Pressure psig Test Temp. _ F

9. Remarks

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A

Signed ". & 2 FL Grass Jr., QA Tech Specialist Date July 15 , 1999 Owner dr Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have inspected the components described in this Owners Report during the period -to L--- 0.. ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

R.D. Klein Commissions NB7728, NC853, N-1 Inspect s S nature National Board, State, Province and Endorsements

Dtate

Page 2 of 2 Revision 6

Page 147: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S RI . - FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XA

1. Owner Address: Duke Power Compan

526 S. Church Street, Charlotte, NC 28201-1006

2. Plant Address:

1 a. Date June 3. 1999 Sheet 1 of 1

McGuire Nuclear Station

12700 Haaqers Ferry Road, Huntersville, NC 28078

2a. Unit: 01 212 03 OShared (specify Units

3. Work Performed By: Duke Power Companv Address: 526 S. Church Street, Charlotte NC 28201-1006

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A

4. (a) Identification of System: SM - Main Steam

3a. Work Order #:

3b. NSM or MM #:

98150372Repair Orgnizo Job #

N/A

4. (b) Class of System: B

5. (a) Applicable Construction Code: ASME I 1971 Edition, Summer and Winter Addenda, (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1989, No Addenda

N/A Code Cases

6. Identification of Components Repaired or Replaced and Replacement Components:

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Repaired, Replaced, or ASME Code Stamped

Replacement (yes or no) A 13 Repaired, EiNo

1-MCA-SM-H1 1 Duke Power 22389 N/A N/A N/A EIReplaced, 0 Replacement 0 Yes

B 0 Repaired, I•No

1-MCA-SM-H11 Duke Power 15720 N/A N/A N/A 0 Replaced, .IReplacement 03 Yes 03 Repaired, 0 No

03 Replaced, _ 0 Replacement 03 Yes

D 10 Repaired, 03 No 03 Replaced, _0 Replacement 03 Yes

E 0 Repaired, 0 No 0 Replaced, _0 Replacement 0 Yes 0 Repaired, 03 No 03 Replaced, _0 Replacement 0 Yes

Page I of 2 Revision 5

Page 148: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replaced Snubber

8. Test Conducted:Hydrostatic E0 Pneumatic 0 Nom. Operating Press. El Other E] Exempto

Pressure psig Test Temp. OF Pressure psig Test Temp. -F Pressure psig Test Temp. OF

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A

Signed -..7 g FL Grass Jr..QA Tech Specialist Date ,/J .19 1.q Owner or Owner's Designee, Titlo

Page 2 of 2 Revision S

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have inspected the components described in this Owners Report during the period &!"I to - : and state that to the best of my knowledge and belief, the Owner has performed examinati6ns and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

-- A, t__Nat Commissions &% rd 7 S 7 rL c 1 5E lnspectorv'sigrture 'National Board, State,'Province and Eri~dorsernents

19-9?

Page 149: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner Address:

2. Plant Address:

-Duke Power Company

526 S. Church Street, Charlotte, NC 28201-1006

Mcguire Nuclear Station

12700 Hagers Ferry Road, Huntersville, NC 28078

Ia. Date 9-26-00

Sheet 1 of

2a. Unit: El 1 ] 2 [] 3 [] Shared (specify units)

3. Work Performed By: Duke Power Company 3a. Work Order# 98182096-16 Repair Otganimatlon Job #

Address: 526 S. Church Street, Charlotte, NC 28201-1006

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 3b. NSM or MM # n/a

4. (a) Identification of System: SV- MAIN STEAM VENT TO ATMO 4. (b) Class of System: B

5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases

(b) Applicable Edition of Section XI Utilizing for Repairs or Replacements: 1989, No Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)

6. Identification of Components Repaired or Replaced and Replacement Components:

Column 1 Column 2 Column 3 Column 4 Column 5 Col. 6 Column 7 Column 8 Repaired, Replaced, or ASME Code

Nam of Component Name of Mfg. Mfg. Serial No. National Board No. Other Identification Year Built Replacement Stamped (yes or no)

A 2SV 7 BABCOCK WILCOX 15958-5-2 12 2SV 1977 M Repaired, 0 No []Replaced,

o Replacement 0 Yes

o] Repaired, 0 No [B Replaced,

I"3 Replacement [3 Yes o Repaired, 0 No

C Replaced,

[] Replacement 0 Yes

D 0 Repaired,. [0 No D Replaced,

[o Replacement 0 Yes

o Repaired, 0 No E 0 Replaced,

[O Replacement 10 Yes

O Repaired, [3 No F [0 Replaced,

[o Replacement 0 Yes

Page I o(2 Revision 7

Page 150: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS -2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used , provided (1) size is 8 1/2 in. x 11 in. (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of work: WELD BUILD UP ON BONNET OF VALVE

8. Test Conducted : Hydrostatic 0 Pneumatic D Nom. Operating Press. 0 Other [I Exempt M

psig psig psig

Test Temp Test Temp Test Temp

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have inspected the components described in this Owner's Report during the period. 7?.e,2. to7C•-6 -C ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

R. D. Klein-44) .t/ Inspectorl 2gf0a4re

Date 966, 20 CO

Commissions NB7728, NC853, N-I National Board, State, Province and Endorsements

Page 2 of 2 Revion 7

Pressure Pressure Pressure

9. Remarks -

OF OF OF

CERTIFICATE OF COMPLIANCE We certify that he statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed E. P. Robinson Exec. Supp.s&&• *i/ Q Date 9-26 20 00

Owner or Owner's IMsign&, Title

Page 151: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPORT As Required By The Provisic

REPAIRS OR REPLACEMENTS rhe ASME Code Section X)

1. Owner Address:

2. Plant Address:

Duke Power Company

526 S. Church Street. Charlotte. NC 28201-1006

Mcguire Nuclear Station

12700 Hagers Ferry Road, Huntersville, NC 28078

2a. Unit: F] I Z 2 [] 3 [] Shared (specify units)

3. Work Performed By: Duke Power Companv 3a. Work Order# 98182096/01

Address: 526 S. Church Street. Charlotte, NC 28201-1006 Repair Organization Job #

Type Code Symbol Stamp: N/A Authorization No. NIA Expiration Date: N/A 3b. NSM or MM # N/A

4. (a) Identification of System: SV 4. (b) Class of System: B

5. (a) Applicable Construction Code: ASME m 1971 Edition, Summer and Winter Addenda, N/A Code Cases

(b) Applicable Edition of Section XI Utilizing for Repairs or Replacements: 1989, No Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)

6. Identification of Components Repaired or Replaced and Replacement Components:

Column 1 Column 2 Column 3 Column 4 Column 5 Col. 6 Column 7 Column 8

Name of Component Name of Mfg. Mfg. Serial No. National Other Year Repaired, ASME Code Board No. Identification Built Replacement no)

A Valve 2SV-7 B & W 15958-5-2 12 SV 1977 0 Repaired, No 0] Replaced,

S0 Replacement 0g Yes B 0 Repaired, [I No B0 Replaced,

[3 Replacement [I Yes

C o Repaired, 0 No C Replaced, 0] Replacement 0 Yes

D o Repaired, 0 No D[3 Replaced, , , [O Replacement 0 Yes

E [o Repaired, 0 No E Replaced,

[] Replacement 0 Yes o 0 Repaired, 0 No F Replaced, [] Replacement 0 Yes

Page I of 2 Revision 7

la. Date

Sheet

10/05/00

I of I

Page 152: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS -2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used , provided (1) size is 8 1/2 in. x 11 in. (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of work: Replaced plug assembly

8. Test Conducted : Hydrostatic [] Pneumatic 0 Nom. Operating Press. E0 Other 0 .. Exempt 0.

Pressure psig Test Temp OF Pressure psig Test Temp OF Pressure psig Test Temp OF

9. Remarks:

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that he statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/._A Certificate of Authorization No. N/A Expiration Date N/A Signed F. R. Sorrow Exec. Supp. ' Date 10/05 20 00

Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have inspected the components described in this Owner's Report during the period Cq.-(. -- 00l to /0-1, --& ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

R. D. K~leiE/ Commissions NB7728, NC853, N-I Inspector's i ture National Board, State, Province and Endorsements

Date (4L- , 2<

Puge 2 of 2 Rciion 7

Page 153: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xl

1. Owner Address: Duke Power Company

2. Plant Address:

526 S. Church Street, Charlotte, NC 28201-1006

McGuire Nuclear Station

la. Date June 29, 2000

Sheet 1 of 1

12700 Hagers Ferry Road, Huntersville, NC 28078

2a. Unit: 01 02 03 OShared (specify Units

3. Work Performed By: j Duke Power Company Address: 526 S, Church Street, Charlotte NC 28201-1006

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A

4. (a) Identification of System: ND - Residual Heat Removal

;I 3a. Work Order #: 98220267 RPe&rOmwhnz.to Jcb#

3b. NSM or MM #: N/A

4. (b) Class of System: B

5. (a) Applicable Construction Code: ASMSJII 19Z1 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989, No Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)

6. Identification of Components Repaired or Replaced and Replacement Components:

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Repaired, Replaced, or ASME Code Stamped

Replacement (yes or no)

A 0 Repaired, PNo 2-MCA-ND-H5508 Duke Power 14936 N/A N/A N/A 0 Replaced,

... _ [Replacement 03 Yes

B 0 Repaired, 0 No 2-MCA-ND-H5508 Duke Power 21746 N/A N/A N/A 0 Replaced,

13 Replacement 03 Yes 0 Repaired, 03 No O3 Replaced, _ _ Replacement E3 Yes

D 10 Repaired, 0 No O Replaced, ]0 Replacement 0 Yes

E 0 Repaired, 0 No 0 Replaced,

-E3 Replacement 0 Yes F 13 Repaired, 03 No

0 Replaced, ____________ ____________________ ________ ____ Replacement 0] Yes

Page 1 of 2 Revision 6

Page 154: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replaced snubber

8. Test Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. 0 Other 0 Exemptlo

Pressure _ _ psig Test Temp. _ OF Pressure psig Test Temp. __ OF Pressure _psig Test Temp. _ OF

9. Remarks

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A

Signed VAe 42 FL Grass Jr..QA Tech Specialist Date 07Ownep'6r Owner's Designee, Titoe

Page 2 of 2 Revision 6

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have inspected the components described in this Owners Report during the period "--A' 0o to "2-L•C and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in the Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

igQ •0 R.D. Klein Commissions NB7728, NC853, N-I n s Natonal Board, State, Province and Endorsements

Date 4 L 9 ;M

Page 155: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner Address:

2. Plant Address:

Duke Power Company

526 S. Church Street, Charlotte, NO 28201-1006

McGuire Nuclear Station

Ia. Date September 11, 2000

Sheet 1 of 1

12700 Hagers Ferry Road, Huntersville, NC 28078

2a. Unit: 01 E12 03 OShared (specify Units

3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A

4. (a) Identification of System: CA - Auxiliary Feedwater

3a. Work Order#: 98221268 Raepek Orgizgq Jeb#

3b. NSM or MM #:

4. (b) Class of System: B

N/A

5. (a) Applicable Construction Code: ASME-II 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989, No Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)

6. Identification of Components Repaired or Replaced and Replacement Components:

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Repaired, Replaced, or ASME Code Stamped Replacement (yes or no)

A C3 Repaired, 0 No

2-MCA-CA-60 Duke Power'. 15679 N/A N/A N/A OReplaced, [0 Replacement 03 Yes

B 03 Repaired, ONo 2-MCA-CA-60 Duke Power 18871 N/A N/A N/A 03 Replaced,

__Replacement 0 Yes C 0 Repaired, 0 No

0 Replaced, _0 Replacement 0 Yes

D 0] Repaired, 0 No 03 Replaced, 13 Replacement 0 Yes

E .0 Repaired, 03 No 0 Replaced, _0 Replacement -0 Yes

0 Repaired, 0 No 0 Replaced,

__ Replacement 0] Yes

Page 1 of2 Revision 6

Page 156: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replaced snubber

8. Test Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. 0 Other 0 Exempt[l

9. Remarks

Pressure -psig Test Temp. °F Pressure psig Test Temp. OF Pressure p psig Test Temp. OF

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A

Signed ,O,4WQ FL Grass Jr., QA Tech Specialist Date // 2a9 Owner or.,ner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have inspected the components described in this Owner's Report during the period 9-5.-OO to +-W'-O and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7728, NC853, N-I National Board, State, Province and Endorsements

S I.-I-. R.D. Klein Dnsapt, or- tignature Date ° ,- aOC6

Page 2 of 2 Revision 6

Page 157: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section X1

1. Owner Address: Duke Power Company

526 S. Church Street, Charlotte, NC 28201-1006

Ia. Date September 11, 2000

Sheet 1 of 1

2. Plant Address:

12700 Hagers Ferry Road,. Huntersville, NC 28078

2a. Unit: 01 E12 03 OShared (specify Units

3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A

4. (a) Identification of System: CA- Auxiliary Feedwater

3a. Work Order #:Repair OrWantlN Job#

3b. NSM or MM #:

4. (b) Class of System: B

N/A

5. (a) Applicable Construction Code: ASME III 19Z. Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section Xi Utilized for Repairs or Replacements: 1989, No Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)

6. Identification of Components Repaired or Replaced and Replacement Components:

Column 1 Column 2 Column 3 . Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Repaired, Replaced, or ASME Code Stamped

_......._Replacement (yes or no)

A 03 Repaired, 0 No 2-MCA-CA-56 Duke Power. 14807 N/A N/A N/A OReplaced,

_0 Replacement 0 Yes B [] Repaired, ONo

2-MCA-CA-56 Duke Power 10734 N/A N/A N/A [] Replaced, []Replacement 0 Yes

C [] Repaired, '0 No 03 Replaced, _ 0 Replacement 0 Yes

D 03 Repaired, 0 No o3 Replaced, _3 Replacement [3 Yes

E .0 Repaired, 03 No 0 Replaced, 03 Replacement 0 Yes F0 Repaired, 0 No O3 Replaced, _0 Replacement 0 Yes

Page 1 of 2 Revision 6

McGuire Nuclear Station

Page 158: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replaced snubber

8. Test Conducted:Hydrostatic 0 Pneumatic El Nom. Operating Press. El Other 0l ExemptO

9. Remarks

Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure _psig Test Temp. OF

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPUANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A

Signed FL Grass Jr., QA Tech Specialist Date /// , Owner o Owner's Designee, Ti

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have inspected the components described in this Owner's Report during the period .---- to ..-)p-o0 ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

SR.D. Klein IDnspe ct'4 Signature Date 01--] , qe 0• 0

Commissions NB7728, NC853, N-I National Board, State, Province and Endorsements

Page 2 of 2 Revision 6

Page 159: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

I. Owner Address:

2. Plant Address:

Duke Power Company

526 S. Church Street. Charlotte, NC 28201-1006

Mcguire Nuclear Station

12700 Hagers Ferry Road, Huntersville, NC 28078

la. Date 09-21-00

Sheet 1 of 1

2a. Unit: [I 1 ] 2 E] 3 F1 Shared (specify units)

3. Work Performed By: Duke Power Company 3a. Work Order # 98237248-10 Repair Organizntion Job #

Address: 526 S. Church Street. Charlotte. NC 28201-1006

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 3b. NSM or MM # MGMM-11289

4. (a) Identification of System: ND RESIDUAL HEAT REMOVAL 4. (b) Class of System: B

5. (a) Applicable Construction Code: ASMEIII 1971 Edition, Summer and Winter Addenda, N/A Code Cases

(b) Applicable Edition of Section XI Utilizing for Repairs or Replacements: 1989, No Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)

6. Identification of Components Repaired or Replaced and Replacement Components:

Column 1 Column 2 Column 3 Column 4 Column 5 Col. 6 Column 7 Column 8 Repaired, Replaced, or ASME Code

Name of Component Name of Mfg. Mfg. Serial No. National Board No. Other Identification Year Built Replacement ___Stamped (yes or no)

A VALVE 2ND 23 BORG WARNER 4626 40 ND 1975 0 Repaired, D No o] Replaced, [o Replacement 0 Yes o[ Repaired, 0 No B"3 Replaced, E3 Replacement 0 Yes

C o Repaired, 0 No [C Replaced,

1 1 [o Replacement [3 Yes D [o Repaired,. 0 No D0 Replaced,

[o Replacement -0 Yes

E [o Repaired, 0 No [0 Replaced, 0] Replacement 03 Yes

O[ Repaired, 0 No [F Replaced,

[I Replacement 0 Yes

Page l of 2 Revision 7

Page 160: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS -2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of work: WELD NEW BACKSTOP ON TO VALVE BONNET

8. Test Conducted: Hydrostatic 0 Pneumatic [] Nom. Operating Press. 0 Other-[] Exempt o

Pressure psig Test Temp OF Pressure psig Test Temp OF Pressure psig Test Temp OF

9. Remarks:

(Applicable Manufacturer's Data Records to be attached)

CIERI'IHCATE OF COMPLIANCE We certify that he statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed E. P. Robinson Exec. Supp. Date 09-21 20 00

Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have inspected the components described in this Owner's Report during the period •"I..O to- ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

R. D. Klein AWO OAA-1

Ing5tor' s Si-Cnure

Date qn 20,

Commissions NB7728, NC853, N-I National Board, State, Province and Endorsements

Page 2 of 2 Revision 7

Page 161: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner Address:

2. Plant Address:

Duke Power Company

526 S. Church Street, Charlotte, NC 28201-1006

Mcguire Nuclear Station

12700 Hagers Ferry Road, Huntersville, NC 28078

la. Date 09-21-00

Sheet 1 of I

2a. Unit: ']l 1 2 F1 3 [] Shared (specify units)

3. Work Performed By: Duke Power Company 3a. Work Order # 98237249-11 Repair Organization Job#

Address: 526 S. Church Street, Charlotte, NC 28201-1006

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 3b. NSM or MM # MGMM- 11289

4. (a) Identification of System: ND RESIDUAL HEAT REMOVAL 4. (b) Class of System: B

5. (a) Applicable Construction Code: ASME fI 1921 Edition, Summer and Winter Addenda, N/A Code Cases

(b) Applicable Edition of Section XI Utilizing for Repairs or Replacements: 1989. No Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)

6. Identification of Components Repaired or Replaced and Replacement Components:

Column 1 Column 2 Column 3 Column 4 Column 5 Col. 6 Column 7 Column 8 Repaired, Replaced, or ASME Code

Name of Component Name of Mfg. Mfg. Serial No. National Board No. Other Identification Year Built Replacement Stamped (yes or no)

A VALVE 2ND 8 BORG WARNER 4625 39 ND 1975 W Repaired, 0 No AR Replaced,

E] Replacement 0 Yes

B [] Repaired, [3 No [o Replaced, E3 Replacement 0 Yes

C oI Repaired, 0 No [] Replaced,

j-[O Replacement 0 Yes D [] Repaired, • 0 No

[D Replaced, [0 Replacement 0l Yes

o Repaired, 0 No E [] Replaced,

]0 Replacement 0 Yes 0 Repaired, 0 No

F [ Replaced, [] Replacement 0 Yes

Page I of 2 Revision 7

Page 162: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS -2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of work: WELD NEW BACKSTOP ON TO VALVE BONNET

8. Test Conducted: Hydrostatic 0 Pneumatic 0 Nom. Operating Press. 0 Other.0 Exempt i

Pressure Pressure Pressure

psig psig psig

Test Temp Test Temp Test Temp

OF OF OF

9. Remarks :

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that he statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp NIA Certificate of Authorization No. N/A

Signed E. P. Robinson Exec. Supp. , Date 09-21 Owner or Owner's Designee, TitlI

T/A

20 00

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have inspected the components described in this Owner's Report during the period >",--o6 to - ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

R. D.Klein Inspecto0rs 'gnade

Date , 20-0

Commissions NB7728, NC853, N-I National Board, State, Province and Endorsements

Page 2 of 2 Rcvision 7

Expiration DateN

Page 163: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner Address:

2. Plant Address:

-Duke Power Company

526 S, Church Street, Charlotte, NC 28201-1006

Mcguire Nuclear Station

12700 Hagers Ferry Road, Huntersville, NC 28078

1 a. Date 09-23-00

Sheet I of 1

2a. Unit: El 1 Z 2 [- 3 EQ Shared (specify units)

3. Work Performed By: Duke Power Company 3a. Work Order# 98251940-30 Repair Organization Job#

Address: 526 S. Church Street, Charlotte, NC 28201-1006

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 3b. NSM or MM # MGMM10698

4. (a) Identification of System: NV CHEM. & VOL. CONTROL 4. (b) Class of System: B

5. (a) Applicable Construction Code: ASME M 1971 Edition, Summer and Winter Addenda, N-416-1 Code Cases

(b) Applicable Edition of Section XI Utilizing for Repairs or Replacements: 1989, No Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)

6. Identification of Components Repaired or Replaced and Replacement Components:

Column 1 Column 2 Column 3 Column 4 Column 5 Col. 6 Column 7 Column 8 Repaired, Replaced, or ASME Code

Name of Component Name of Mfg. Mfg. Serial No. National Board No. Other Identification Year Built Replacement Stamped (yes or no)

A PIPING DUKE POWER N/A .80 2NV 1982 0 Repaired, 0 No [3 Replaced, ,, Cg Replacement 0 Yes

B [3 Repaired, 0 No t. [0 Replaced,

S.... O] Replacement [3 Yes C [3 Repaired, [3 No

[o Replaced, [3 Replacement Q Yes

D 0 Repaired, [3 No D 0 Replaced, [I Replacement [3 Yes

E 0 Repaired, 0 No [0 Replaced,

0] Replacement 0 Yes [0 Repaired, 03 No F3 Replaced,

I [o Replacement [3 Yes

Page I of2 Revision 7

Page 164: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS -2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used , provided (I) size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of work: ADD FET=INGS FOR HP & LP INSTR. LOOP

2NVLT 5761 FOR VCT

8. Test Conducted: Hydrostatic " Pneumatic 0 Nom. Operating Press. 0 Other 4J Exempt [

32 psig psig psig

Test Temp 75 Test Temp Test Temp

CERTIFICATE OF COMPLIANCE We certify that he statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A I/A

20 00Signed E. P. Robinson Exec. Supp_ Date 09-29 Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have inspected the components described in this Owner's Report during the period :%4QS:f)C to q.-30W ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

R. D. Klein % JA Inspector's Si-gature

Date 930 ,20

Commissions NB7728, NC853, N-I National Board, State, Province and Endorsements

Pressure Pressure Pressure

9. Remarks :

OF OF OF

(Applicable Manufacturer's Data Records to be attached)

Page 2 of 2 Revision 7

Exniration Date, N

Page 165: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPORT As Required By The Provisio.

REPAIRS OR REPLACEMENTS rhe ASME Code Section XI

1. Owner Address:

2. Plant Address:

Duke Power Company

526 S. Church Street. Charlotte, NC 28201-1006

Mcguire Nuclear Station

12700 Hagers Ferry Road, Huntersville, NC 28078

2a. Unit: [] 1 0 2 E] 3 E] Shared (specify units)

3. Work Performed By: Duke Power Company 3a. Work Order# 98252135

Address: 526 S. Church Street. Charlotte, NC 28201-1006 Repair Organization Job #

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 3b. NSM or MM # N/A

4. (a) Identification of System: SM 4. (b) Class of System: B

5. (a) Applicable Construction Code: ASME M 1971 Edition, Summer and Winter Addenda, N/A Code Cases

(b) Applicable Edition of Section XI Utilizing for Repairs or Replacements: 1989, No Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)

6. Identification of Components Repaired or Replaced and Replacement Components:

Column 1 Column 2 Column 3 Column 4 Column 5 Col. 6 Column 7 Column 8

Name of Component Name of Mfg. Mfg. Serial No. National Other Year Repaired, ASME Code Board No. Identification Built Replacement no)

OReplairmed, 0 No

A Valve Kerotest JH13-2 6985 2SM-18 1975 [3 Repaired, 0 No [] Replaced, _ Replacement 0 Yes

B o Repaired, 0 No O Replaced, [o Replacement 0 Yes

C 0 Repaired, 0 No [C Replaced,

0] Replacement [0 Yes D o Repaired, 0 No

0 Replaced, [] Replacement 0 Yes

E O Repaired, [3 No [E Replaced,

]0 Replacement 0l Yes El Repaired, El No

F 0[ Replaced,

_E Replacement El Yes

Page I of2 Revision 7

la. Date

Sheet

09/29/00

1 of 1

Page 166: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS -2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used , provided (1) size is 8 1/2 in. x 11 in. (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of work: Replaced valve disc

8. Test Conducted: Hydrostatic [] Pneumatic 0

Pressure

Pressure Pressure

psig

psig psig

Nom. Operating Press. 0 Other 0 Exempt 0

Test Temp

Test Temp

Test Temp

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that he statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A

Signed F. R. Sorrow Exec. Supp. Date 09/29 20 00 Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have inspected the components described in this Owner's Report during the period -ýg•-'..O to i-3c.0•O . ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

R. D. Ki Commissions NB7728, NC853, N-I

Inspector's Sigialure National Board, State, Province and Endorsements

Date ,-SQ 0 20A)Q,

Pge 2 of 2 Revisiok 7

9. Remarks :

OF

OF OF

Page 167: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPOR.3 As Required By The Provisi(

REPAIRS OR REPLACEMENTS The ASME Code Section XI

1. Owner Address:

2. Plant Address: M

12

2a. Unit: F1 I] 2 [1

3. Work Performed By:

Address:

Duke Power Company

526 S. Church Street Charlotte, NC 28201-1006

Ia. Date

Sheet

09/29/00

1 of 1

cguire Nuclear Station

700 Hagers Ferry Road, Huntersville, NC 28078

3 E] Shared (specify units)

Duke Power Company

526 S. Church Street, Charlotte, NC 28201-1006

3a. Work Order # 98258913/03 Repair

Organization Job #

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 3b. NSM or MM # 11580

4. (a) Identification of System: RF 4. (b) Class of System: B

5. (a) Applicable Construction Code: ASME II 1971 Edition, Summer and Winter Addenda, N/A Code Cases

(b) Applicable Edition of Section XI Utilizing for Repairs or Replacements: 1989 No (1992 through 1992 Addenda for Class MC and CC and their supports) Addenda

6. Identification of Components Repaired or Replaced and Replacement Components:

Column I Column 2 Column 3 Column 4 Column 5 Col. 6 Column 7 Column 8

Name of Component Name of Mfg. Mfg. Serial No. National Board Other Year Repaired, ASME Code No. Identification Built Replaced, or Stamped (yes or

Replacement no)

A Valve TRW J6814 11 1RF-834 1979 0 Repaired, 0 No [] Replaced, 0[] Replacement 0 Yes

B Vvalve Anderson N15031 14 IRF-834 1982 [ Repaired, 0 No

Greenwood [0 Replaced, __ Replacement 0 Yes

C 0 Repaired, 0 No 0 Replaced, [3 Replacement 0 Yes

D [O Repaired, 0 No D0 Replaced,'

11 Replacement 0 Yes O[ Repaired, 0 No E0 Replaced, o Replacement 0 Yes O1 Repaired, 0 No 0 Replaced, 0] Replacement 0 Yes

Page I of 2 Revision 7

Page 168: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS -2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of work: Replaced valve, studs and nuts in flange

8. Test Conducted : Hydrostatic C) Pneumatic [I Nom. Operating Press. [D Other 0 Exempt []

Pressure psig Test Temp OF Pressure psig Test Temp OF Pressure psig Test Temp OF

9. Remarks:

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that he statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed F. R. Sorrow Exec. Su Date 09/29 20 00

Owner or Owner"s Designee, Title

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have inspected the components described in this Owner's Report during the period r---04 to9•ga--00 ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

R. D. KleinA Commissions NB7728, NC853, N-I Inspector's Signure National Board, State, Province and

Endorsements

Date -q _9 200

Pa€g 2 of 2 Revixkln 7

Page 169: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner Address:

2. Plant Address:

Ia. Date 09-23-00

Sheet 1 of I

-Duke Power Company

526 S. Church Street, Charlotte, NC 28201-1006

Mcguire Nuclear Station

12700 Hagers Ferry Road, Huntersville, NC 28078

2a. Unit: C 1 0 2 El 3 0 Shared (specify units)

3. Work Performed By: Duke Power Company 3a. Work Order # 98263089-13 Repair Organization Job #

Address: 526 S. Church Street, Charlotte. NC 28201-1006

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 3b. NSM or MM # N/A

4. (a) Identification of System: SV MAIN STEAM VENT TO ATMOS. 4. (b) Class of System: B

5. (a) Applicable Construction Code: ASME 1111971 Edition, Summer and Winter Addenda, N/A Code Cases

(b) Applicable Edition of Section XI Utilizing for Repairs or Replacements: 1989, No Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)

6. Identification of Components Repaired or Replaced and Replacement Components:

Column 1 Column 2 Column 3 Column 4 Column 5 Col. 6 Column 7 Column 8 Repaired, Replaced, or ASME Code Name of Component Name of Mfg. Mfg. Serial No. National Board No. Other Identification Year Built Replacement Stamped Cyes or no)

A VALVE 2SV 13 BABCOCK WILCOX 15958-5-3 13 SV 1977 0 Repaired, [3 No [3 Replaced,

.. [0 Replacement 0 Yes

B O Repaired, El No [B Replaced, [0 Replacement 0 Yes [] Repaired, 0 No

C 0[ Replaced, [o Replacement 0 Yes

D El Repaired,. 0 No o Replaced, 1o Replacement 0 Yes.

E0 Repaired, [3 No E ]0 Replaced,

[o Replacement 0 Yes

0 Repaired, 0 No F0 Replaced, 0o Replacement 0 Yes

Page I of 2 Revision 7

Page 170: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS -2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used , provided (1) size is 8 1/2 in. x II in. (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of work: WELD BUILDUP ON BONNET OF VALVE

8. Test Conducted: Hydrostatic 0 Pneumatic [] Nom. Operating Press. 0 Other.Q Exempt o

Pressure Pressure Pressure

psig psig psig

Test Temp Test Temp Test Temp

OF OF OF

9. Remarks :

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that he statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A [/A

20 00Signed E. P. Robinson Exec. Supp. 5 _ Date 09-23

Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have inspected the components described in this Owner's Report during the period 9 ,4 qC4O!. to I-1j, ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

R. D. Klein Inspector' - nature

Date 4-.3 20(SXP

Commissions NB7728, NC853, N-I National Board, State, Province and Endorsements

Page 2 of 2 Revision 7

•xnir:•ticm I'•t,•. NT

Page 171: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPORT As Required By The Provisio

ZEPAIRS OR REPLACEMENTS fhe ASME Code Section XI

1. Owner Address:

2. Plant Address:

Duke Power Comnany

526 S. Church Street, Charlotte, NC 28201-1006

Mcguire Nuclear Station

12700 Hagers Ferry Road, Huntersville, NC 28078

2a. Unit: [I- 1 [ 2 E] 3 [] Shared (specify units)

3. Work Performed By: Duke Power Company 3a. Work Order # 98263089/01

Address: 526 S. Church Street, Charlotte, NC 28201-1006 Repair Organization Job #

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 3b. NSM or MM # N/A

4. (a) Identification of System: SV 4. (b) Class of System: B

5. (a) Applicable Construction Code: ASME m 197L Edition, Summer and Winter Addenda, N/A Code Cases

(b) Applicable Edition of Section XI Utilizing for Repairs or Replacements: 1989, No Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)

6. Identification of Components Repaired or Replaced and Replacement Components:

Column 1 Column 2 Column 3 Column 4 Column 5 Col. 6 Column 7 Column 8

Name of Component Name of Mfg. Mfg. Serial No. National Other Year Repaired, ASME Code Board No. Identification Built Replaced, or Stamped (yes or BoaN . dReplacement no)

A Valve 2SV-13 B & W 15958-5-3 13 SV 1977 D Repaired, 0 No O] Replaced,

[0 Replacement 0 Yes o] Repaired, E] No o Replaced, [I Replacement [3 Yes

C o Repaired, 0 No

o Replaced, [] Replacement 0 Yes

D ol Repaired, 0 No D Replaced, D] Replacement 0 Yes

oE Repaired, 0 No ""0 Replaced,

"O Replacement 0 Yes

o] Repaired, 0] No ""0 Replaced,

[I Replacement 0 Yes

Page I of 2 Revision 7

la. Date

Sheet

10/05/00

1 of 1

Page 172: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS -2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used , provided (1) size is 8 1/2 in. x II in. (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of work: Replaced plug assembly

8. Test Conducted: Hydrostatic 0 Pneumatic []

Pressure Pressure

Pressure

psig psig

psig

Nom. Operating Press. 0 Other 0 Exempt E

Test Temp Test Temp

Test Temp

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that he statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A

Signed F. R. Sorrow Exec. Supp. ,_.. -.. 4,.. Date 10/05 20 00 Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have inspected the components described in this Owner's Report during the period c--0-..o to 1.-6 -- 'DO ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

R. D. Klein ---- JA... Commissions NB7728, NC853, N-I Inspector's Sigature National Board, State, Province and Endorsements

Date (0-(0 200"'

Pag, 2 of 2 Rvismn 7

9. Remarks :

OF OF OF

Page 173: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPORT FOR REPAIRSOR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner Address: Duke Power Company

526 S. Church Street, Charlotte, NC 28201-1006

2. Plant Address:

Ia. Date September 22, 2000

Sheet 1 of 1

McGuire Nuclear Station

12700 Hagers Ferry Road, Huntersville, NC 28078

2a. Unit: 01 E2 03 OShared (specify Units )

3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A

4. (a) Identification of System: NV - Chemical and Volume Control

3a. WorkOrder#:

3b. NSM or MM #:

4. (b) Class of System: B

98264158Repalr Orgenization Job#

MGMM-1 1127

5. (a) Applicable Construction Code: ASMEIII 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1989, No Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)

6. Identification of Components Repaired or Replaced and Replacement Components:

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Repaired, Replaced, or ASME Code Stamped Replacement (yes or no)

A 0 Repaired, lNo 2-MCR-NV-5180 Duke Power N/A N/A N/A N/A 03 Replaced,

.__._I__Replacement 03 Yes B 0 Repaired, 0 No

0 Replaced, _0 Replacement 03 Yes

C 0 Repaired, 03 No 03 Replaced, 0 Replacement 0 Yes

D 03 Repaired, 0 No 03 Replaced, [0 Replacement 0 Yes

E 0 Repaired, 0 No 03 Replaced, ""_ Replacement 03 Yes

"0 Repaired, 0 No "0 Replaced,

]0 Replacement 0 Yes

Page 1 of 2 Revision 7

Page 174: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replaced spring can

8. Test Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. 0 Other EJ ExemptlZ

Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure _psig Test Temp. OF

9. Remarks

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A

Signed FL Grass Jr., QA Tech Specialist Date ___,

&Oner, OrOwner's Designee, lWte

Page 2 of 2 Revision 7

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Coinpany of Hartford Connecticut have inspected the components described in this Owner's Report during the period -o . to .'-f-OO : and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this ins

R.D. Klein Commissions NB7728, NC853, N-I Inspectors Signatu a- National Board, State, Province and Endorsements

Date gýA'- COD

Page 175: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner Address:

2. Plant Address:

Duke Power Company

526 S. Church Street. Charlotte, NC 28201-1006

Mcguire Nuclear Station

12700 Hauers Ferry Road. Huntersville, NC 28078

la. Date 10-10-00

Sheet 1 of I

2a. Unit: - 1 Z 2 El 3 [1 Shared (specify units)

3. Work Performed By: Duke Power Company 3a. Work Order # 98264158-15 Repair Organization Job#

Address: 526 S. Church Street, Charlotte, NC 28201-1006

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 3b. NSM or MM # MGMM1 1127

4. (a) Identification of System: NV CHEM. & VOL. CONTROL 4. (b) Class of System: B

5. (a) Applicable Construction Code: ASME HI 1971 Edition, Summer and Winter Addenda, N-416-1 Code Cases

(b) Applicable Edition of Section XI Utilizing for Repairs or Replacements: 1989, No Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)

6. Identification of Components Repaired or Replaced and Replacement Components:

Column 1 Column 2 Column 3 Column 4 Column 5 Col. 6 Column 7 Column 8 Repaired, Replaced, or ASME Code Name of Component Name of Mfg. Mfg. Serial No. National Board No. Other Identification Year Built Replacement Stamped (Cyes or no

A VALVE 2NV 454 CCI 100072-1-2 55 2NV 2000 [0 Repaired, 0 No o3 Replaced,

S.0 [ Replacement 0 Yes

B HANGER 2MCR-NV- DUKE POWER N/A N/A N/A 2000 D Repaired, 0 No o[ Replaced, 5180 ._ 0 Replacement 0 Yes

C 0 Repaired, E3 No [C Replaced, [o Replacement 0 Yes

D O Repaired,. E No 0 Replaced, [o Replacement [3 Yes

E 0 Repaired, [3 No E0 Replaced, r0O Replacement 0 Yes o] Repaired, 0 No F0 Replaced, I-1 Replacement 10 Yes

Page 1 of 2 Revision 7

Page 176: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS -2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used , provided (1) size is 8 1/2 in. x I I in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of work: REPLACE VALVE 2NV 454 & SPRING CAN ON HGR

2 MCR-NV-5180 (ITEM # 15)

8. Test Conducted: Hydrostatic [I Pneumatic 0 Nom. Operating Press. 0 Other 0

9. Remarks : ONE SIDE OF VALVE IS 2235 PSIG AND 330 PSIG ON OTHER SIDE

(Applicable Manufacturer's Data Records to be attached)

Test Temp 260 Test Temp Test Temp

OF OF OF

Pressure 2235 psig Pressure 330 psig Pressure psig

Exempt []

CERTIFICATE OF COMPLIANCE We certify that he statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp NIA Certificate of Authorization No. N/A Expiration Date N/A Signed F. R. Sorrow Exec. Supp .-• All, ý Date 10-10 20 00

Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have ins ted the components described in this Owner's Report during the period c-1-O0 to -/-11M ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

R. D. Kh Commissions NB7728, NC853, N-I Inspector's Si at e National Board, State, Province and Endorsements

Date / 2, 20(

Page 2 of 2 Revision 7

Page 177: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section X1

1. Owner Address:

2. Plant Address:

1 a. Date October 9. 2000

Sheet 1 of 1Duke Power Company

526 S. Church Street, Charlotte, NC 28201-1006

McGuire Nuclear Station

12700 Hagers Ferry Road, Huntersville, NC 28078

2a. Unit: 01 E2 03 OShared (specify Units

3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A

4. (a) Identification of System: SM - Main Steam

3a. Work Order#:

3b. NSM or MM #:

98265754 Repair OW&Won Job #

N/A

4. (b) Class of System: B

5. (a) Applicable Construction Code: ASME III 197t Edition, Summer and Winter Addenda, N/A Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989, No Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)

6. Identification of Components Repaired or Replaced and Replacement Components:

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identificatlon Year Built Repaired, Replaced, or ASME Code Stamped

Replacement (yes or no)

A 03 Repaired, 03 No

2-SM-VA-1AB Atwood - Morrell 5-623 N/A N/A 1976 0 Replaced, _iReplacement E[Yes

B 0 Repaired, 03 No o3 Replaced, E3 Replacement 03 Yes

C C3 Repaired, 03 No o Replaced,

_0 Replacement 03 Yes D 0 Repaired, 0 No

0 .Replaced,

_3 Replacement 0 Yes E 0 Repaired, 0 No

"0 Replaced,

""] Replacement 0 Yes

F [0 Repaired, 03 No 03 Replaced,

[0 Replacement 0 Yes

Page 1 of 2 Revision 7

Page 178: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replaced Plug

8. Test Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. IOther 0 Exempto

Pressure psig Test Temp. F__ F Pressure _ psig Test Temp. OF Pressure _ _ psig Test Temp. - OF

9. Remarks

(Applicable Manufactureres Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are conrct and this repair or replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A

Signed t FL Grass Jr, QA Tech Specialist Date _,__

4 n rwner's De.mgne, Te

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I ConLpany of Hartford Connecticut have inspected the components described in this Owners Report during the period -4,6 to/o-',-- C) and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

S NR.D. Klein Commissions NB7728, NC853, N-I InspectoeirS~jnature National Board, State, Province and Endorsements

Date -d O

Page 2 of 2 Revision 7

Page 179: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPOR:,' As Required By The Provisw.

REPAIRS OR REPLACEMENTS The ASME Code Section XI

1. Owner Address:

2. Plant Address:

Duke Power Company

526 S. Church Street. Charlotte, NC 28201-1006

Mcguire Nuclear Station

12700 Hagers Ferry Road, Huntersville, NC 28078

2a. Unit: l 1 Z 2 El 3 [1 Shared (specify units)

3. Work Performed By: Duke Power Company 3a. Work Order # 98267345/01

Address: 526 S. Church Street, Charlotte, NC 28201-1006 Repair Organization Job #

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 3b. NSM or MM # N/A

4. (a) Identification of System: NV 4. (b) Class of System: B

5. (a) Applicable Construction Code: ASME 111 1971 Edition, Summer and Winter Addenda, N/A Code Cases

(b) Applicable Edition of Section XI Utilizing for Repairs or Replacements: 1989, No Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)

6. Identification of Components Repaired or Replaced and Replacement Components:

Page I of 2 Revision 7

Ia. Date

Sheet

09/26/00

1 of 1

Column I Column 2 Column 3 Column 4 Column 5 Col. 6 Column 7 Column 8

Name of Component Name of Mfg. Mfg. Serial No. National Other Year Repaired, ASME Code Board No. Identification Built Replaced, or Stamped (yes or

a NReplacement no)

O' Repaired, 0] No A Valve Kerotest SVF- 1-25 16712 2NV-77 1977 3 Repaced,

[]Replaced, __ Replacement [ Yes

B [o Repaired, 0 No [B Replaced,

[] Replacement 03 Yes

C O Repaired, 0 No C Replaced,

[] Replacement El Yes D Repaired, El No

D Replaced,

[O Replacement 0 Yes

E [] Repaired, El No 0 Replaced,

I 1 o Replacement 1 l Yes

F o] Repaired, El No FE Replaced,

0_ Replacement D Yes

Page 180: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS -2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of work: Replaced Disc Assembly

8. Test Conducted : Hydrostatic 0 Pneumatic [I Nom. Operating Press. 0 Other 0 Exempt [

psig psig

psig

Test Temp Test Temp Test Temp

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that he statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A Expiration Date N/A Signed F. R. Sorrow Exec. Supp.- Date 09/26 20 00

Owner or Owner s Designee, Title

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have inspected the components described in this Owner's Report during the period 3fjlC-,> to -qnQ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

R. D. Klein & Commissions NB7728, NC853, N-I nspector's"Signiauure National Board, State, Province and Endorsements

Date , 20

Page 2 ,,f 2

Revison 7

Pressure

Pressure Pressure

9. Remarks :

OF OF

OF

Page 181: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner Address:

2. Plant Address:

Duke Power Company

526 S. Church Street. Charlotte, NC 28201-1006

Mcguire Nuclear Station

12700 Haters Ferry Road, Huntersville, NC 28078

I a. Date 09-23-00

Sheet I of 1

2a. Unit: [] 1 ] 2 E" 3 E] Shared (specify units)

3. Work Performed By: Duke Power Company 3a. Work Order # 98279643-06 Rermttr Organization Job #

Address: 526 S. Church Street, Charlotte, NC 28201-1006

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 3b. NSM or MM # MGMM-1 1844

4. (a) Identification of System: FW REFUELING WATER 4. (b) Class of System: B

5. (a) Applicable Construction Code: ASNEI M 1971 Edition, Summer and Winter Addenda, N/A Code Cases

(b) Applicable Edition of Section XI Utilizing for Repairs or Replacements: 1989, No Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)

6. Identification of Components Repaired or Replaced and Replacement Components:

Page I of 2 Revision 7

Column I Column 2 Column 3 Column 4 Column 5 Col. 6 Column 7 Column 8 Name of Component Name of Mfg. Mfg. Serial No. National Board No. Other Identification Year Built Repaired. Replaced, or ASME Code

Replacement St0am (yes or no)

A FW PIPING DUKE POWER N/A 54 2FW 1982 I- Repaired, [3 No C3 Replaced, M0 Replacement M Yes

B o Repaired, E3 No B3 Replaced,

0] Replacement [3 Yes

o[ Repaired, [3 No C [ Replaced,

0o Replacement [3 Yes D O Repaired, 0 No [D Replaced,

0] Replacement 0 Yes o Repaired, 0 No

E 0 Replaced, 1 o Replacement 10 Yes o] Repaired, 0 No

[F Replaced, I [] Replacement 0 Yes

Page 182: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS -2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used , provided (1) size is 8 1/2 in. x 11 in. (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of work: INSTALL HALF/CPLG ASSEMBLY TO ENCAPSULATE

2FWTX 5050.

8. Test Conducted : Hydrostatic 0 Pneumatic 0 Nom. Operating Press. 0 Other [I Exempt Z]

psig psig psig

Test Temp Test Temp Test Temp

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have ins eted the components described in this Owner's Report during the period 4--'7-O ) to q~ P-L0 ;and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

R. D. Klein "YUT"?iAv Ins, itr's Sigh ,ure

Date g-T , 20O

Commissions NB7728, NC853, N-I National Board, State, Province and Endorsements

Pagc 2 of 2 Revsion 7

Pressure Pressure Pressure

9. Remarks :

OF OF OF

CERTIFICATE OF COMPLIANCE We certify that he statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed E. P. Robinson Exec. Supp. " Date 09-23 20 00

Owner or Owner's Designee, Title

Page 183: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner Address:

2. Plant Address:

1 a. Date 10-09-00

Sheet 1 of 1

Duke Power Company

526 S. Church Street, Charlotte, NC 28201-1006

Mcguire Nuclear Station

12700 Hagers Ferry Road, Huntersville, NC 28078

2a. Unit: [-E]I [D 2 E] 3 [] Shared (specify units)

3. Work Performed By: Duke Power Company 3a. Work Order# 98312376-05 Repair Organization Job #

Address: 526 S. Church Street, Charlotte, NC 28201-1006

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 3b. NSM or MM # MGMM11989

4. (a) Identification of System: NV CHEMICAL &VOLUME CONTROL 4. (b) Class of System: B

5. (a) Applicable Construction Code: ASME 1I 1921 Edition, Summer and Winter Addenda, N-416-1 Code Cases

(b) Applicable Edition of Section XI Utilizing for Repairs or Replacements: 1989, No Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)

6. Identification of Components Repaired or Replaced and Replacement Components:

Column 1 Column 2 Column 3 Column 4 Column 5 Col. 6 Column 7 Column 8 Repaired, Replaced, or ASME Code Name of Component Name of Mfg. Mfg. Serial No. National Board No. Other Identification Year Built Replacement Stamped (yes or no)

197 E Repaired, El No A VALVE 2NV 151A KEROTEST CAB22-8 2538 2NV 1979 0 Replaced,

[] Replacement 0 Yes

VALVE 2NV 151A KEROTEST AEC1-6 35770 2NV 1983 El Repaired, 0 No o Replaced, __ Replacement El Yes

o] Repaired, [I No D0 Replaced, [3 Replacement [3 Yes

D Repaired, 0[ No

D E0 Replaced, _ _ Replacement 0l Yes

E 0 Repaired,' [3 No E [] Replaced,

0] Replacement [3 Yes

El Repaired, 0l No F l[ Replaced,

[E Replacement El Yes

Page I of 2 Revision 7

Page 184: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS -2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I) size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of work: REPLACE VALVE 2NV151A

8. Test Conducted : Hydrostatic 0 Pneumatic 0 Nom. Operating Press. 0 Other 0 Exempt 0

2640 psig psig psig

Test Temp 100 Test Temp Test Temp

9. Remarks :

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that he statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A

Signed E. P. Robinson Exec. Supp.-46 & "_ Owner or Owner's Designee, 1lide

Expiration Date N/A

Date 10-09 20 00

Pressure Pressure Pressure

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have inspected the components described in this Owner's Report during the period 4]--0 to/--- ;and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

R. D. Klei Commissions NB7728, NC853, N-I Inspectd `s ,ature National Board, State, Province and Endorsements

Datet(f•2- ' 20f9

Page 2 of 2 Rcvision 7

OF OF

OF

Page 185: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

1. Owner Address: Duke Power Company

526 S. Church Street, Charlotte, NC 28201-1006

2. Plant Address:

Ia. Date September 12, 2000 Sheet 1 of 1

McGuire Nuclear Station

12700 Hagers Ferry Road, Huntersville, NC 28078

2a. Unit: 01 02 03 0Shared (specify Units _

3. Work Performed By: Duke Power Company Address: 526 S. Church Street, Charlotte NC 28201-1006

Type Code Symbol Stamp: N/A Authorization No. NIA Expiration Date: N/A

4. (a) Identification of System: SM - Main Steam

3a. Work Order#:

3b. NSM or MM #:

98312407 Reperf Or lza n Jcb#

N/A

4. (b) Class of System: B

5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989. No Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)

6. Identification of Components Repaired or Replaced and Replacement Components:

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Repaired, Replaced, or ASME Code Stamped

__________Reclacemrrit (yes or no) [AA 10 Repaired, EfNo

2MCA-SM-HG-0064 Duke Power 6457 N/A N/A N/A 0 Replaced, _.... _EReplacement 3 Yes

0 Repaired, 03 No

0 Replaced, [] Replacement 0 Yes 0 Repaired, 03 No 03 Replaced,

0 Replacement 03 Yes D 10 Repaired, 03 No

0 .Replaced,

_0 Replacement 03 Yes

E 0 Repaired, 0 No 0 Replaced,

_0 Replacement 0 Yes

F 0 Repaired, 0 No 0 Replaced,

.0 [0 Replacement 0 Yes

Page 1 of 2 Revision 6

Page 186: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of WorkRenlaced nivot nin

8. Test Conducted:Hydrostatic El Pneumatic 0l Nom. Operating Press. El Other El ExemptlZ

9. Remarks

Pressure _ _ psig Test Temp. OF Pressure _psig Test Temp. OF Pressure _psig Test Temp. OF

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/AI Certificate of Authorization No. N/A Expiration Date N/A

Signed :-/ - FL Grass Jr., QA Tech Specialist Date _.,_

Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have inspected the components described in this Owner's Report during the period *-'- to ?--/7'.J ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. istr, t R.D. Klein Commissions NB7728, NC853, N-I Inspector%'Siqnature National Board, State, Province and Endorsements

Date fEJ3.

Page 2 of 2 Revision 6

<

Page 187: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPOR1 As Required By The Provisi

REPAIRS OR REPLACEMENTS lhe ASME Code Section XI

1. Owner Address:

2. Plant Address:

Duke Power Company

526 S. Church Street. Charlotte, NC 28201-1006

Mcguire Nuclear Station

12700 Hagers Ferry Road, Huntersville, NC 28078

2a. Unit: "-1 ] 2 E] 3 [] Shared (specify units)

3. Work Performed By: Duke Power Comnany 3a. Work Order # 98317278/06

Address: 526 S. Church Street, Charlotte, NC 28201-1006 Repair Organization Job #

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 3b. NSM or MM # N/A

4. (a) Identification of System: NV 4. (b) Class of System: B

5. (a) Applicable Construction Code: ASME ImI 1971 Edition, Summer and Winter Addenda, N/A Code Cases

(b) Applicable Edition of Section XI Utilizing for Repairs or Replacements: 1989, No Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)

6. Identification of Components Repaired or Replaced and Replacement Components:

Column 1 Column 2 Column 3 Column 4 Column 5 Col. 6 Column 7 Column 8

Name of Component Name of Mfg. Mfg. Serial No. National Other Year Repaired, ASME Code Board No. Identification Built Replaced, or Stamped (yes or B Replacement no)

A Piping Duke Power N/A 80 2NV 1982 [] Repaired, 13 No [3 Replaced, __ Replacement 0 Yes

B[ Repaired, 0 No [B Replaced, [3 Replacement Q Yes

C O Repaired, 0 No C0 Replaced, [O Replacement , Yes

D [o Repaired, 0 No [] Replaced, [3 Replacement 0l Yes

E E] Repaired, [I No [E Replaced,

]0 Replacement [3 Yes F [] Repaired, 0 No [F Replaced,

__ Replacement [0 Yes

Page I of 2 Revision 7

Ia. Date

Sheet

10/09/00

1 of I

Page 188: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS -2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of work: Replaced studs and nuts in 2NV99FL- I at valve 2NV-93

8. Test Conducted: Hydrostatic [] Pneumatic 0 Nom. Operating Press. El Other C1 Exempt g

psig psig

psig

Test Temp Test Temp

Test Temp

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that he statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A

Signed F. R. Sorrow Exec. SuppzI -O-.k Date 10/09 20 00 Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have inspected the components described in this Owner's Report during the period q-!q to 0Jzý ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

R. D. Klei •& ý Commissions NB7728, NC853, N-I Inspector'Cai -t ue National Board, State, Province and Endorsements

Date/ Q/ , 20-00

Page 2 of 2 R-iswn 7

Pressure Pressure

Pressure

9. Remarks :

OF OF OF

Page 189: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

FORM NIS-2 OWNER'S REPOP As Required By The Provisie

ZEPAIRS OR REPLACEMENTS fhe ASME Code Section XI

1. Owner Address:

2. Plant Address:

Duke Power Company

526 S. Church Street, Charlotte, NC 28201-1006

Mcguire Nuclear Station

12700 Hagers Ferry Road, Huntersville, NC 28078

2a. Unit: F1 1 S 2 F1 3 F1 Shared (specify units)

3. Work Performed By: Duke Power Company 3a. Work Order# 98317575/01

Address: 526 S. Church Street. Charlotte, NC 28201-1006 Repair Organization Job #

Type Code Symbol Stamp: N/.A Authorization No. N/A Expiration Date: N/A 3b. NSM or MM # 12030

4. (a) Identification of System: NV 4. (b) Class of System: B

5. (a) Applicable Construction Code: ASME m 1971 Edition, Summer and Winter Addenda, N/A Code Cases

(b) Applicable Edition of Section XI Utilizing for Repairs or Replacements: 1989, No Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)

6. Identification of Components Repaired or Replaced and Replacement Components:

_ Column 1 Column 2 Column 3 Column 4 Column 5 Col. 6 Column 7 Column 8 !Repaired, ASME Code

Name of Component Name of Mfg. Mfg. Serial No. National Other Year Repaied, ASme Cod Board No. Identification Built Replacement no)

A 2MCA-NV-5313 DUKE POWER N/A N/A N/A N/A 0 Repaired, 0 No E3 Replaced,

• • [0 Replacement [3 Yes o] Repaired, 0l No o Replaced, [o Replacement El Yes

C El Repaired, El No [o Replaced, El Replacement [3 Yes

D [I Repaired, 0l No El Replaced, _ _ Replacement [3 Yes

El Repaired, El No E] Replaced, 1_ El Replacement El Yes

El Repaired, El No [E Replaced, 0E Replacement El Yes

Page I of 2 Revixion 7

la. Date

Sheet

10/07/00

1 of I

Page 190: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Form NIS -2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used , provided (1) size is 8 1/2 in. x II in. (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of work: Cut out and replaced 3/16" weld between item #1 and #4

8. Test Conducted: Hydrostatic [] Pneumatic 0 Nom. Operating Press. [] Other 0 Exempt 0

psig psig

psig

Test Temp

Test Temp Test Temp

Pressure Pressure

Pressure

9. Remarks :

OF

OF OF

(Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that he statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed F. R. Sorrow Exec. Supp.. - ' Date 10/07 20 00

Owner or Owner's Designee, Title

1, -ýý

CERTIFICATE OF INSERVICE INSPECTION L the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBI and I Company of Hartford Connecticut have inspected the components described in this Owner's Report during the period t)'- O to A '•0 ;and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

R. D. Klein Commissions -NB7728, NC853, N-I Inspectors.gna re National Board, State, Province and Endorsements

Pge 2 of 2 Revisko 7

Page 191: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

11.0 Pressure Testinc,

There are three refueling outages scheduled for the second period of the second inspection interval for Duke Power Company's McGuire Nuclear Station Unit 2. This section describes Pressure Tests performed for the second period through

the 2000 refueling outage (also referred to as EOC-13). *The seven remaining Inservice/Functional pressure tests and the three remaining Hydrostatic pressure tests will be summarized in a special report that will cover a time period from the end of EOC-13 until the expiration of the second period on March 1, 2001.

Total Total (%)

Examination Test Requirement Examinations Examinations Examinations

Category Required For Credited For Complete For This Period This Period This Period

B-E System Hydrostatic 0 0 0%

B-P System Leakage Test 3 3 100% (IWB-5221)

B-P System Hydrostatic 0 0 0% Test (IW B-5222) .. . •° ;, . . ....

C-H System 35 *28 80% Inservice/Functional

Test (IWC-5221)

C-H System Hydrostatic 16 *13 81.25% Test (IWC-5222) _

A detailed description of each Examination Category listed above is located in

subsection 11.1 of this report. Results of each Examination Category are located in subsection 11.2 of this report.

*The 7 Category C-H Inservice/Functional pending items are as follows:

C07.030.012, C07.030.020, C07.030.027, C07.030.028, C07.030.031, C07.030.032, & C07.030.034.

*The 3 Category C-H Hydrostatic pending items are as follows: C07.040.018,

C07.040.019, & C07.040.021.

Refueling Outage Report EOC13 McGuire Unit 2 Section 11

Page 1 of 4 Revision 0 December 5, 2000

Page 192: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

11.1 Required Examinations This Outage:

A listing of each VT-2 Visual Examination that is required for EOC-13 through the end of the second period is included in this section.

The information shown below is a field description for the listing format included in this section of the report:

Item No.

ISI Drawing

Required Test

System Name

Required Inspection

Required Procedure

Comments

=ASME Section XI Tables IWB-2500-1 (Class 1) and IWC-2500-1 (Class 2)

= Detail Drawing of Inspection Boundary

= Type of Pressure Test

= Name of Pressure Retaining Component System

= Type of Visual Examination Required

= Required Inspection Procedure

= General and/or Detail Description

Refueling Outage Report EOC13 McGuire Unit 2 Section 11

Page 2 of 4 Revision 0 December 5, 2000

Page 193: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Duke Power Company - McGuire Unit 2 Pressure Testing Item Number Listing

Outage 13

ISI Item Number Drawing

B15.050.001 SEE COMMENTS

Required Test

LEAKAGE

System Name

NC SYSTEM

Required Inspection

VT-2

Required Procedure

QAL-15Comments

Class A Leakage Boundary Dwgs: MCL-2553-1.0, MCL-2553-2.0, MCL-2554-1.0, MCL-2554-1.1, MCL-2554-1.2, MCL-2561-1.0, MCL-2562-1.0, MCL-2562-2.0, MCL-2562-2.1, MCL-2562-3.0, MCL-2562-3.1

This Report Was Generated On: 12/05/2000

Page 194: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Duke Power Company - McGuire Unit 2 Pressure Testing Item Number Listing

Outage 13

Item Number

C07.030.005

C07.030.010

C07.030.012

C07.030.015

G07.030.018

C07.030.020

C07.030.026

C07.030.027

C07.030.028

C07.030.031

C07.030.032

ISI Drawing

MCL-2561 -1.0

MCL-2562-3.1

MCL-2563-1 .0

MCL-2571 -1.0

MCL-2572-1.1

MCL-2572-3.0

MCL-2580-1.0

MCL-2584-1.0

MCL-2591 -1.1

MCL-2592-1.0

MCL-2593-1.2

Required Test

INSER

System Name

ND SYSTEM

INS/FUN NI SYSTEM

INS/FUN NS SYSTEM

INSER FW SYSTEM

INSER NM SYSTEM

FUNC NM SYSTEM

INS/FUN BB SYSTEM

INSER BW SYSTEM

INS/FUN CF SYSTEM

INS/FUN CA SYSTEM

INSER SA/TE SYSTEM

Required Inspection

VT-2

VT-2

VT-2

VT-2

VT-2

VT-2

VT-2

VT-2

VT-2

VT-2

VT-2

Required Procedure

QAL-15

QAL-15

Comments

VT-2 Examination of C02.033.001 & C02.033.002 Telltale Hole also required for ND HX 2A.

This test is required for periods 1,2 and 3

QAL-1 5 VT-2 Examination of C02.033.005 and C02.033.006

Telltale Hole also required for NS HX 2A. This system is partially complete for the 2nd period but

will be 100% complete by 3/1/2001.

QAL-1 5 This test is required for periods 1,2 and 3

Penetrations 2M-358 and 2M-377 - Reference PIP#2-M95-0043

QAL-15 Penetration M-280 - Reference PIP#2-M95-0043

QAL-1 5 Class B penetrations M-335, M-338, M-340 and

M-341. This system is partially complete for the 2nd period but will be 100% complete by 3/1/2001.

QAL-1 5 Penetrations M-300, M-301, M-303 and M-304

QAL-1 5 This system has not been tested for the 2nd period

but will be 100% complete by 3/1/2001.

QAL-15 Penetrations M-153, M-262, M-308 and M-440. Thit,

system is partially complete for the 2nd period but will be 100% complete by 3/1/2001.

QAL-1 5 Penetrations M-1 56, M-286, M-465 and M-31 00. This system is partially complete for the 2nd period

but will be 100% complete by 3/1/2001.

QAL-15 This system is partially complete for the 2nd period

This Report Was Generated On: 12/05/2000

Page 195: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Duke Power Company - McGuire Unit 2 Pressure Testing Item Number Listing

Outage 13

Item Number

C07.030.034

C07.040.006

C07.040.017

C07.040.018

C07.040.019

C07.040.021

IS1 Drawing

MCL-2617-1.0

MCH-2554-1.1

MCH-2562-2.1

MCH-2562-3.0

MCH-2562-3.1

MCH-2563-1.0

Required Test

INSER

System Name

YA SYSTEM

HYDRO NV SYSTEM

HYDRO NISYSTEM

HYDRO NISYSTEM

HYDRO NISYSTEM

HYDRO NS SYSTEM

Required Required Inspection Procedure

VT-2

VT-2

VT-2

VT-2

VT-2

VT-2

Comments

but will be 100% complete by 3/1/2001.

OAL-15 Reference PIP#2-M95-0043. This system has not been tested for the 2nd period but will be 100% complete by 3/1/2001.

QAL-1 5 This test is required for periods 2 and 3 Penetrations M-256, M-343 and M-344

QAL-15 This test is required for periods 2 and 3 Penetration M-321

QAL-1 5 This test is required for periods 2 and 3 Penetrations M-277, M-316 and M-319. This systerr is partially complete for the 2nd period but will be 100% complete by 3/1/2001.

QAL-1 5 This test is required for periods 2 and 3. This system is partially complete for the 2nd period but will be 100% complete by 3/1/2001.

QAL-1 5 VT-2 Examination of C02.033.005 and C02.033.006 Telltale Hole also required for NS HX 2A. This system is partially complete for the 2nd period but will be 100% complete by 3/1/2001.

This Report Was Generated On: 12/05/2000

Page 196: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

11.2 Examination Results For This Outage:

The results of each VT-2 Visual Examination that is required for EOC-13 through the end of the second period is included in this section

The information shown below is a field description for the listing format included in this section of the report:

Item Number

ISI Drawing

Required Test

Test Status

Test Result

VT-2 Date

Comments

=ASME Section XI Tables IWB-2500-1 (Class 1) and IWC-2500-1 (Class 2)

= Detail Drawing of Inspection Boundary

= Type of Pressure Test

- Complete, Partial, Not Tested, or Not Required

= Clear, Recordable, or Reportable

= Date VT-2 Visual Examination Was Performed

= General and/or Detail Description

Refueling Outage Report EOC13 McGuire Unit 2 Section 11

Page 3 of 4 Revision 0 December 5, 2000

Page 197: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Duke Power Company - McGuire Unit 2 Pressure Testing VT-2 Results For Outage 13

ISI Item Number Drawing

B1 5.050.001 SEE COMMENTS

Required Test Test Status

LEAKAGE COMPLETE

Test Result

CLEAR

VT-2 Date Comments

10/10/2000 Class A Leakage Boundary Dwgs: MCL-2553-1.0, MCL-2553-2.0, MCL-2554-1.0, MCL-2554-1.1, MCL-2554-1.2, MCL-2561-1.0, MCL-2562-1.0, MCL-2562-2.0, MCL-2562-2.1, MCL-2562-3.0, MCL-2562-3.1

This Report Was Generated On: 12/05/2000

Page 198: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Duke Power Company - McGuire Unit 2 Pressure Testing VT-2 Results For Outage 13

Item Number

C07.030.005

C07.030.010

C07.030.012

C07.030.015

C07.030.018

C07.030.020

C07.030.026

C07.030.027

C07.030.028

C07.030.031

C07.030.032

ISI Drawing

MCL-2561 -1.0

MCL-2562-3.1

MCL-2563-1 .0

MCL-2571 -1.0

MCL-2572-1.1

MCL-2572-3.0

MCL-2580-1 .0

MCL-2584-1.0

MCL-2591 -1.1

MCL-2592-1.0

MCL-2593-1.2

Required Test

INSER

INS/FUN

INS/FUN

INSER

INSER

FUNC

INS/FUN

INSER

Test Status

COMPLETE

COMPLETE

PARTIAL

COMPLETE

COMPLETE

PARTIAL

COMPLETE

NOT TESTED

INS/FUN PARTIAL

INS/FUN PARTIAL

INSER PARTIAL

Test Result

CLEAR

CLEAR

CLEAR

CLEAR

CLEAR

CLEAR

CLEAR

N/A

CLEAR

CLEAR

CLEAR

VT-2 Date Comments11/19/1998 VT-2 Examination of C02.033.001 & C02.033.002 Telltale

Hole also required for ND HX 2A.

04/13/1999 This test is required for periods 1,2 and 3

03/14/1999 VT-2 Examination of C02.033.005 and C02.033.006 Telltale Hole also required for NS HX 2A. This system is partially complete for the 2nd period but will be 100% complete by 3/1/2001.

03/30/1999 This test is required for periods 1,2 and 3 Penetrations 2M-358 and 2M-377 - Reference PIP#2-M95-0043

12/27/1999 Penetration M-280 - Reference PIP#2-M95-0043

04/13/1999 Class B penetrations M-335, M-338, M-340 and M-341. This system is partially complete for the 2nd period but will be 100% complete by 3/1/2001.

12/27/1999 Penetrations M-300, M-301, M-303 and M-304

/ / This system has not been tested for the 2nd period but will be 100% complete by 3/1/2001.

04/13/1999 Penetrations M-1 53, M-262, M-308 and M-440. This system is partially complete for the 2nd period but will be 100% complete by 3/1/2001.

04/13/1999 Penetrations M-1 56, M-286, M-465 and M-31 00. This system is partially complete for the 2nd period but will be 100% complete by 3/1/2001.

07/31/1997 This system is partially complete for the 2nd period but will be 100% complete by 3/1/2001.

This Report Was Generated On: 12/05/2000

Page 199: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

Duke Power Company - McGuire Unit 2 Pressure Testing VT-2 Results For Outage 13

Item Number

C07.030.034

C07.040.006

C07.040.017

C07.040.018

C07.040.019

C07.040.021

ISI Drawing

MCL-2617-1.0

MCH-2554-1.1

MCH-2562-2.1

MCH-2562-3.0

MCH-2562-3.1

MCH-2563-1.0

Required Test

INSER

Test Status

NOT TESTED

HYDRO COMPLETE

HYDRO COMPLETE

HYDRO PARTIAL

HYDRO PARTIAL

HYDRO PARTIAL

Test Result

N/A

CLEAR

CLEAR

CLEAR

CLEAR

CLEAR

VT-2 Date //

Comments

Reference PIP#2-M95-0043. This system has not been tested for the 2nd period but will be 100% complete by 3/1/2001.

12/27/1999 This test is required for periods 2 and 3 - Penetrations M-256, M-343 and M-344

03/13/1999

12/28/1998

This test is required for periods 2 and 3 - Penetration M-321

This test is required for periods 2 and 3 Penetrations M-277, M-316 and M-319. This system is partially complete for the 2nd period but will be 100% complete by 3/1/2001.

11/02/1998 This test is required for periods 2 and 3. This system is partially complete for the 2nd period but will be 100%

complete by 3/1/2001.

11/02/1998 VT-2 Examination of C02.033.005 and C02.033.006 Telltale Hole also required for NS HX 2A. This system is partially complete for the 2nd period but will be 100% complete by 3/1/2001.

This Report Was Generated On: 12/05/2000

Page 200: Duke Duke Energy Corporation McGuire Nuclear StationB01.020 Head Welds B01.021 Circumferential 0 B01.022 B01.030 B01.040 B01.050 B01.051 TOTALS Meridional Shell-to-Flange Welds Head-to-Flange

11.3 Reportable Indications:

None

Refueling Outage Report EOC13 McGuire Unit 2 Section 11

Page 4 of 4 Revision 0 December 5, 2000