duplexvent multi - airflow.com commercial pdfs... · 1 airflow.com floor standing (maintenance...
TRANSCRIPT
airflow.com1
Floor standing(Maintenance access from the top)
Ceiling suspended(Maintenance access from the bottom)
Duplexvent MULTIHeat Recovery Ventilation
KEY FEATURES
MULTI LINE UNIT CONFIGURATIONS
Duplexvent MULTI
● Heat recovery ventilation● 100% customisation ● 93% thermal efficiency ● Low energy EC fans● Automatic 100% bypass● Built-in heating / cooling coils ● Integrated web server enables to control the unit
via internet● BMS connection (Modbus as a standard, optional
BACnet or KNX)● VAV control compatibility● 2 year warranty +
As a ventilation specialist we aim to provide ventilation solutions for commercial applications thanks to our broad range of Commercial Heat Recovery units in excess of 16,000 m3/hr air volume with the availability of indoor and outdoor versions.
To accomplish this goal, our Passive House approved, ex-stock Flexi Line units provide the highest thermal efficiency with immediate delivery whilst our customised Multi and Rotary Line units match your specification in terms of installation flexibility, performance and quality by meeting the high air volume requirements for commercial and large industrial spaces.
+ excludes motors. Motor warranty one year from date of purchase.
2016 / 2018
Horizontal(Maintenance access from the side)
airflow.com2
100% Bypass facility delivers cool, fresh and filtered air
Circulation damper helps regulate indoor temperature / humidity conditions
Built-in water / DX coils extra heating / cooling
885 mm2500 mm
1600
mm
665 mm2300 mm
1600
mm
1065 mm2500 mm
1600
mm
384 mm1600 mm
765
mm
455 mm2300 mm
1600
mm
580 mm2300 mm
1600
mm
1 290 mm2500 mm
1600
mm
384 mm1800 mm
970
mm
1620 mm3370 mm
1795
mm
2100 mm3370 mm
1795
mm
Multi DV500 Multi DV1000 Multi DV1500 Multi DV2500 Multi DV3500
Multi DV5000 Multi DV6500 Multi DV8000 Multi DV10000 Multi DV11000
DUPLEXVENT MULTI SIZE RANGE
100% CUSTOMISATION AND SHORT DELIVERY TIMEMulti Line MVHR units follow the business philosophy of multiple variability. Designers can easily modify unit positions, spigot connections, filters, integral heating /cooling coils, bypass and circulation dampers using the selection software which accelerates the specification process and helps meet stringent project requirements.
Despite the full customisation Multi Line units are delivered in a period of 4-6 weeks to meet tight project deadlines.
airflow.com3
l/sec0
500
400
300
100
200
800
900
1000
700
600
2500 1000 1250 200017501500 2250 2500 2750 3000 3250 3500 3750500 750
0
STAT
IC P
RESS
URE
(Pa)
AIR FLOWm /hr3 1000 2000 3000 4000 6000 7000 8000 9000 10000 11000 12000 130005000
Supply section (with G4 filter)Supply section (with T.3+CHW.5+G4 filter)Supply section (with T.3+CHW.5+F7 filter)Exhaust section (with G4 filter)
Mu
lti DV
500
Mu
lti DV
1000
Mu
lti DV
1500
Mu
lti DV
2500
Mu
lti DV
3500
Mu
lti DV
5000
Mu
lti DV
6500
Mu
lti DV
8000
Mu
lti DV
10000
Mu
lti DV
11000
Duplexvent MULTIMulti Line Customised Indoor - Up to 13050m3/hr air volume
Duplexvent Multi DV500 DV1000 DV1500 DV2500 DV3500 DV5000 DV6500 DV8000 DV10000 DV11000
Supply air - max.1 m3/hr / l/sec 660 / 183 1200 / 333 2200 / 611 3400 / 944 4600 / 1278 6400 / 1778 7100 / 1972 9600 / 2667 11100 / 3083 13050 / 3625
Extraction air - max.1 m3/hr / l/sec 670 / 186 1150 / 319 1800 / 500 3200 / 889 4200 / 1166 6350 / 1764 7050 / 1958 9100 / 2528 10700 / 2972 12300 / 3417
Heat recovery efficiency 2 % up to 93%
Fan type EC (backward curved impeller)
Weight 3 kg 80-110 95-130 200-280 290-370 320-390 370-450 480-560 580-670 1170-1280 1230-1350
Max power input kW 0.3 0.7 1.2 2.6 4.5 6.7 7.3 9.3 10.7 10.8
Voltage V 230 400
Frequency Hz 50
RPM - max. min-1 4300 3350 2920 3000 2980 2700 2820 2570 2570 2130
Heating output T - max.4 kW 5 14 22 30 42 51 71 88 95 100
Cooling output CHW - max.4 kW 4 8 16 22 30 42 56 62 65 70
Cooling output CHF - max.4 kW 3 6 10 13 25 37 41 50 60 65
Part No. 9041571 9041572 9041573 9041521 9041522 9041523 9041524 9041525 90000815 90000816
Type Workingpoint
Acoustic power LW [dB(A)] Acoustic pressure Lp [dB(A)]
at 3 m inlet e1 inlet i1 inlet e2 inlet i2 unit
Duplexvent Multi DV500 500m3/hr (200Pa) 53 66 80 82 59 38
Duplexvent Multi DV1000 1000m3/hr (200Pa) 66 65 85 86 62 42
Duplexvent Multi DV1500 1500m3/hr (200Pa) 61 61 86 86 64 43
Duplexvent Multi DV2500 2500m3/hr (200Pa) 59 55 79 79 70 49
Duplexvent Multi DV3500 3500m3/hr (200Pa) 60 59 91 88 70 49
Duplexvent Multi DV5000 5000m3/hr (200Pa) 68 67 91 93 78 48
Duplexvent Multi DV6500 6500m3/hr (200Pa) 70 71 95 95 76 55
Duplexvent Multi DV8000 8000m3/hr (200Pa) 75 74 99 96 69 49
Duplexvent Multi DV10000 9000m3/hr (200Pa) 66 67 98 97 74 53
Duplexvent Multi DV11000 10000m3/hr (200Pa) 63 64 88 88 73 52
1. Maximum flow rate at zero external pressure2. According to air volume3. Depending on equipment4. Depending on register type, liquid and flow rates
T - Water heating coilCHW - Water cooling coilCHF - DX (direct evaporator) coil
KEY FEATURES
PERFORMANCE
ACOUSTIC POWER LW AND PRESSURE Lp
● �Fully customised commercial units in 10 different sizes up to 12500 m3/hr at 200 Pa
● �Digital touchscreen or simple manual controller● �Low noise, refer to NR35 and BB93 standards● �Excellent thermal insulation (class T2, TB1)● �G4, M5 or F7 filters available ● �Optional circulation damper● �Optional constant flow and constant
pressure mode● �BREEAM and ErP 2016 / 2018 compliant● �Meets Building Regulations Part L2A and L2B
2016 / 2018
Duplexvent Multi DV500 DV1000 DV1500 DV2500 DV3500 DV5000 DV6500 DV8000 DV10000 DV11000
Dimension H mm 765 970 1600 1600 1600 1600 1600 1600 1795 1795
Dimension H2 mm 715 920 1650 1650 1650 1650 1650 1650 - -
Dimension B mm 384 384 455 580 665 885 1065 1295 / 1390* 1620 1620
Length L mm 1600 1800 2300 2300 2300 2500 2500 2500 3370 3370
Length L2 mm 1652 1852 2270 2270 2270 2470 2470 2368 - -
Condensate drain mm Ø22 Ø32
Connecting Ports
Dimension X1 x Y1 (standard e1, i1), D mm Ø200 Ø250 Ø315 300 x 400 400 x 400 500 x 500 500 x 500 700 x 500 900 x 710 900 x 710
Dimension X2 x Y2 (atypical e1, i1), D mm Ø200 Ø250 400 x 200 300 x 400 400 x 400 500 x 500 500 x 500 500 x 700 - -
Dimension X3 x Y3 (standard e2, i2) mm 200 x 250 200 x 350 Ø315 450 x 710 500 x 710 710 x 710 900 x 710 900 x 710 - -
Dimension X4 x Y4 (atypical e2, i2) mm - - - 250 x 355 250 x 400 355 x 630 355 x 800 355 x 900 400 x 1200 400 x 1200
*For Duplexvent Multi DV8000 in configuration 30/X
door
door
X3 (Ø D)B
Y3
Y1
X1 (Ø D)
Y4
FLOOR-STANDING (front view)Multi DV10000 to DV11000
UNDERCEILING (top view)Multi DV500 to DV8000alternative spigot position
(configuration 30/10)
FLOOR-STANDING FLAT (top view)Multi DV1500 to DV6500alternative spigot position
(configuration 41/10)
FLOOR-STANDING (front view)Multi DV500 to DV8000
C B
alternative spigot position(conf iguration 30/10)
H2
L2
C B
alternative spigot position(conf iguration 41/10)
X1 (ØD)X4 (ØD)
Y2
X2 X2
door
Y4
X4 (ØD)
door
Y4
X4 (ØD)
Y4
X4 (ØD)door
Y4
X4 (ØD)
Y4
X4 (ØD)
K K K
C B
405 x 305L
H20
010
0
doorX1 (ØD)
B
X1 (ØD)
405 x 305L
H10
0Y
2
Y2
X2 X2
door
Y2
405 x 305L
H10
0
Y3
Y1
Y3
Y1
X1 (ØD)B
door
150
L671 1 403 1 296
2100*B
Y1
Y1
X1
X1
X4 X4
Y4
Y4
200
H
alternative spigotposition(configuration 11/10)
2500 1000 1250 200017501500 2250 2500 2750 3000 3250 3500500 750
0AIR FLOW
1000 2000 3000 4000 6000 7000 8000 9000 10000 11000 120005000
100
90
70
80
Ther
mal
Effic
ienc
y %
m3/hr
l/sec
1500 3500
2500
500
10005000
6500
8000 1100010000
for te1= -15°C, t,1= +20°C, rh1= 55%, Mi = Mefor te1= +5°C, t,1= +25°C, rh1= 40%, according to EN 308
2500 1000 1250 200017501500 2250 2500 2750 3000 3250 3500500 750
0AIR FLOW
1000 2000 3000 4000 6000 7000 8000 9000 10000 11000 120005000
100
50
75
0
25
Heati
ng / c
oolin
g cap
acity
(kW
)
m3/hr
l/sec
5001500
10002500
35005000
65008000
1100010000
Max. heating capacity for water heaterMax. cooling capacity for water and DX cooler
Max. capacity data T are valid for 70/50°C water temperature drop and +10°C, r.h. 10% supply air (after recovery)Max. cooling capacity data CHW are valid for 30% water / ethylene-glycol mixture, 6/12°C temperature drop, +30°C, r.h. 50% supply air
PERFORMANCE
DIMENSIONS
*Only for Duplexvent Multi DV11000
E-mail: [email protected]: +44 (0) 1494 525252
airflow.com
© Airflow Developments Limited. Airflow Developments Limited reserve the right, in the interests of continuous development, to alter specifications without prior notice. All orders are accepted subject to our conditions of sale which are available on request
Certificate No. EMS 569454BS EN 1SO 14001 : 2015
Certificate No. FM 00152BS EN 1SO 9001 : 2015
Airflow Developments LimitedAidelle House, Lancaster Road,Cressex Business Park,High Wycombe, Buckinghamshire,United Kingdom, HP12 3QP
Call: 01494 560800 Visit: airflow.com80000674 Issue 1 06/17