Page 1: Dura Mate - Amphenol Sine Systems ISOBUS… · 174 Dura|Mate ISOBUS IMPLEMENT CONNECTOR Features and Benefits • Compatible to ISO 11783-2 • #8 power contacts for 6/10/16mm ²

173

CO

NN

ECTO

R SO

LUTIO

NS

ISOBUS IMPLEMENT CONNECTOR

Dura|Mate™

Dura|Mate™

Page 2: Dura Mate - Amphenol Sine Systems ISOBUS… · 174 Dura|Mate ISOBUS IMPLEMENT CONNECTOR Features and Benefits • Compatible to ISO 11783-2 • #8 power contacts for 6/10/16mm ²

174

Dura|Mate ISOBUS IMPLEMENT CONNECTOR

Features and Benefits

• Compatible to ISO 11783-2• #8 power contacts for 6/10/16mm ² wire gauge• Machined and stamped contcts #12 &#16 available• Rapid and secure assembly• Field installable cable connectors as well as overmolded cable assemblies available

Areas of Applications

• Connection between tractor and implement• Standardized connection according to ISO 11783-2

General CharacteristicsNumber of contacts 2+2+4+1Contacts 2x#8 + 2x#12 + 5x #16 (1x bridged)Wire Gauge 2x6/10/16mm ² + 2 x 2.5mm ² + 4 x 0.5mm ²Rated Voltage 24VDCMax. Curent Carrying Capacity (EIA-364-112)

#8: 60A / #12: 25A / #16: 13A

Pollution Degree 3Temperaure Range Cable connectors:

-40°C to +125°COvermolded Cable Assemblies-20°C to +85°C

IP Degree of Protection IP67/IP6K9KMechanical Lifeime >100 mating cyclesLocking System Bayonet

MaterialsHousing Polyamide black, UL94 V-0Overmold Polyurethane black, UL94 HBInserts Polyamide black, UL94 V-0Sealing NBR, SiliconeContacts Copper alloy, nickel or gold plated

Tecnical Data

Page 3: Dura Mate - Amphenol Sine Systems ISOBUS… · 174 Dura|Mate ISOBUS IMPLEMENT CONNECTOR Features and Benefits • Compatible to ISO 11783-2 • #8 power contacts for 6/10/16mm ²

175

CO

NN

ECTO

R SO

LUTIO

NS

9 POSITION PLUGS & PLUG KITS DURA|MATE ISOBUS

9 POSITIONS 60A,25A,13A

Contact Size 8 12 16Contact Qty 2 2 5 (1x bridged)Wire Range 7-10 AWG 10-14 AWG 16-20 AWGAmperage 60 25 13

Part Number DescriptionAHDP06-24-91S-BS1 Isobus Plug with Cable Gland 14-18mm Cable DiameterAHDP06-24-91S-BS2 Isobus Plug with Conduit Adapter NW17AHDP06-24-91S-BS3 Isobus Plug with Conduit Adapter NW23

Plug KitsPart Number DescriptionAHDP06-24-91S-BS1-K06M Isobus connector for 14-18mm cable diameter, Kit incl. Contacts

(2x VN 02 036 0026 6 ; 2x AT62-203-12141; 4x AT62-201-16141)AHDP06-24-91S-BS1-K06S Isobus connector for 14-18mm cable diameter, Kit incl. Contacts

(2x VN 02 036 0026 6 ; 2x AT62-12-0166; 4x AT62-16-0822)AHDP06-24-91S-BS1-K06X Isobus connector for 14-18mm cable diameter, Kit incl. Contacts

(2x VN 02 036 0026 6 ; 2x AT62-12-0166; 4x AT62-16-0622)AHDP06-24-91S-BS1-K10M Isobus connector for 14-18mm cable diameter, Kit incl. Contacts

(2x VN 02 036 0027 6 ; 2x AT62-203-12141; 4x AT62-201-16141)AHDP06-24-91S-BS1-K10S Isobus connector for 14-18mm cable diameter, Kit incl. Contacts

(2x VN 02 036 0027 6 ; 2x AT62-12-0166; 4x AT62-16-0822)AHDP06-24-91S-BS1-K10X Isobus connector for 14-18mm cable diameter, Kit incl. Contacts

(2x VN 02 036 0027 6 ; 2x AT62-12-0166; 4x AT62-16-0622)AHDP06-24-91S-BS1-K16M Isobus connector for 14-18mm cable diameter, Kit incl. Contacts

(2x VN 02 036 0028 6 ; 2x AT62-203-12141; 4x AT62-201-16141)AHDP06-24-91S-BS1-K16S Isobus connector for 14-18mm cable diameter, Kit incl. Contacts

(2x VN 02 036 0028 6 ; 2x AT62-12-0166; 4x AT62-16-0822)AHDP06-24-91S-BS1-K16X Isobus connector for 14-18mm cable diameter, Kit incl. Contacts

(2x VN 02 036 0028 6 ; 2x AT62-12-0166; 4x AT62-16-0622)AHDP06-24-91S-BS2-K06M Isobus connector with conduit adapter NW17, Kit incl. Contacts

(2x VN 02 036 0026 6 ; 2x AT62-203-12141; 4x AT62-201-16141)AHDP06-24-91S-BS2-K06S Isobus connector with conduit adapter NW17, Kit incl. Contacts

(2x VN 02 036 0026 6 ; 2x AT62-12-0166; 4x AT62-16-0822)AHDP06-24-91S-BS2-K06X Isobus connector with conduit adapter NW17, Kit incl. Contacts

(2x VN 02 036 0026 6 ; 2x AT62-12-0166; 4x AT62-16-0622)

Plugs

Page 4: Dura Mate - Amphenol Sine Systems ISOBUS… · 174 Dura|Mate ISOBUS IMPLEMENT CONNECTOR Features and Benefits • Compatible to ISO 11783-2 • #8 power contacts for 6/10/16mm ²

176

AHDP06-24-91S-BS2-K10M Isobus connector with conduit adapter NW17, Kit incl. Contacts (2x VN 02 036 0027 6 ; 2x AT62-203-12141; 4x AT62-201-16141)

AHDP06-24-91S-BS2-K10S Isobus connector with conduit adapter NW17, Kit incl. Contacts (2x VN 02 036 0027 6 ; 2x AT62-12-0166; 4x AT62-16-0822)

AHDP06-24-91S-BS2-K10X Isobus connector with conduit adapter NW17, Kit incl. Contacts (2x VN 02 036 0027 6 ; 2x AT62-12-0166; 4x AT62-16-0622)

AHDP06-24-91S-BS2-K16M Isobus connector with conduit adapter NW17, Kit incl. Contacts (2x VN 02 036 0028 6 ; 2x AT62-203-12141; 4x AT62-201-16141)

AHDP06-24-91S-BS2-K16S Isobus connector with conduit adapter NW17, Kit incl. Contacts (2x VN 02 036 0028 6 ; 2x AT62-12-0166; 4x AT62-16-0822)

AHDP06-24-91S-BS2-K16X Isobus connector with conduit adapter NW17, Kit incl. Contacts (2x VN 02 036 0028 6 ; 2x AT62-12-0166; 4x AT62-16-0622)

AHDP06-24-91S-BS3-K06M Isobus connector with conduit adapter NW23, Kit incl. Contacts (2x VN 02 036 0026 6 ; 2x AT62-203-12141; 4x AT62-201-16141)

AHDP06-24-91S-BS3-K06S Isobus connector with conduit adapter NW23, Kit incl. Contacts (2x VN 02 036 0026 6 ; 2x AT62-12-0166; 4x AT62-16-0822)

AHDP06-24-91S-BS3-K06X Isobus connector with conduit adapter NW23, Kit incl. Contacts (2x VN 02 036 0026 6 ; 2x AT62-12-0166; 4x AT62-16-0622)

AHDP06-24-91S-BS3-K10M Isobus connector with conduit adapter NW23, Kit incl. Contacts (2x VN 02 036 0027 6 ; 2x AT62-203-12141; 4x AT62-201-16141)

AHDP06-24-91S-BS3-K10S Isobus connector with conduit adapter NW23, Kit incl. Contacts (2x VN 02 036 0027 6 ; 2x AT62-12-0166; 4x AT62-16-0822)

AHDP06-24-91S-BS3-K10X Isobus connector with conduit adapter NW23, Kit incl. Contacts (2x VN 02 036 0027 6 ; 2x AT62-12-0166; 4x AT62-16-0622)

AHDP06-24-91S-BS3-K16M Isobus connector with conduit adapter NW23, Kit incl. Contacts (2x VN 02 036 0028 6 ; 2x AT62-203-12141; 4x AT62-201-16141)

AHDP06-24-91S-BS3-K16S Isobus connector with conduit adapter NW23, Kit incl. Contacts (2x VN 02 036 0028 6 ; 2x AT62-12-0166; 4x AT62-16-0822)

AHDP06-24-91S-BS3-K16X Isobus connector with conduit adapter NW23, Kit incl. Contacts (2x VN 02 036 0028 6 ; 2x AT62-12-0166; 4x AT62-16-0622)

Part Number Description

Plug Kits - (con’t)

Page 5: Dura Mate - Amphenol Sine Systems ISOBUS… · 174 Dura|Mate ISOBUS IMPLEMENT CONNECTOR Features and Benefits • Compatible to ISO 11783-2 • #8 power contacts for 6/10/16mm ²

177

CO

NN

ECTO

R SO

LUTIO

NS

9 POSITION ISOBUS - CONTACTS & ACCESSORIES

Contact Size

Part No. Type Wire Gauge AMP Plating

8 VN02 036 0026 6 Machined 6 mm² 60 Nickel8 VN02 036 0027 6 Machined 10 mm² 60 Nickel8 VN02 036 0028 6 Machined 16 mm² 60 Nickel12 AT60-203-12141 Machined 12-14 AWG 25 Nickel12 AT62-12-0166 Stamped 12-14 AWG 25 Nickel12 AT62-210-1231 Machined 12-14 AWG 25 Gold12 AT62-12-0144 Stamped 12-14 AWG 25 Gold16 AT62-201-16141 Machined 16-20 AWG 13 Nickel16 AT62-16-0822 Stamped 0.34 - 0.50mm² 13 Nickel16 AT62-16-0622 Stamped 18-20 AWG 13 Nickel16 AT62-201-1631 Machined 16-20 AWG 13 Gold16 AT62-16-0844 Stamped 0.34 - 0.50mm² 13 Gold16 AT62-16-0644 Stamped 18-20AWG 13 Gold

Part NumberAHDC04-24-PMSize 24 Protective Plug Cap panel mount

Part NumberAHDC04-24-PMTSize 24 Protective Plug Cap panel mount,with nylon cord

Part NumberAHDC06-24Size 24 Receptacle cap, sealed

Part NumberAHDC04-24-TSize 24 Protective Plug Cap with nylon cord

Page 6: Dura Mate - Amphenol Sine Systems ISOBUS… · 174 Dura|Mate ISOBUS IMPLEMENT CONNECTOR Features and Benefits • Compatible to ISO 11783-2 • #8 power contacts for 6/10/16mm ²

178

DURA|MATE 7 POSITIONS

25A,80ADimensional Drawings

DURA|MATE ISOBUS 9 POSITIONS

60A,25A,13A

AHDP06-24-91S-BS1

AHDP06-24-91S-BS2

AHDP06-24-91S-BS3