dust explosion classifications

4
Combustible Dust Policy Institute Combustible Dust Policy Institute Photo: CSB Don’t Be Mislead Dust Explosion Classes (St 1, St 2, St 3) Imperial Sugar Refinery

Upload: combustible-dust-policy-institute

Post on 12-Jun-2015

1.346 views

Category:

Business


0 download

DESCRIPTION

Don't be mislead in dust explosion classifications that a St 1 (weak explosion) is less severe than a St 3 (very strong explosion) in human causalities and property damage as the result of catastrophic dust explosions.

TRANSCRIPT

Page 1: Dust Explosion Classifications

Combustible Dust Policy InstituteCombustible Dust Policy Institute

Photo: CSB

Don’t Be MisleadDust Explosion Classes (St 1, St 2, St 3)

Imperial Sugar Refinery

Page 2: Dust Explosion Classifications

Combustible Dust Policy InstituteCombustible Dust Policy Institute

Dust explosionclass

Kst (bar.m/s) Characteristic Material

St 0 0 No explosion Silica

St 1 >0 and <=200 Weak

explosion

Powdered milk,charcoal, sulfur,

sugar & zinc

St 2 >200 and <=300

Strong explosion

Wood Flour

St 3 >300 Very Strong explosion

Aluminum, & Magnesium

Dust Explosion Classes

Page 3: Dust Explosion Classifications

Combustible Dust Policy InstituteCombustible Dust Policy Institute

A Weak Explosion? St 1

SUGAR DUST EXPLOSION14 Killed, 36 Injured

Imperial Sugar Refinery PORT WENTWORTH, GEORGIA FEBRUARY 7, 2008

Photo: CSB

Page 4: Dust Explosion Classifications

Combustible Dust Policy InstituteCombustible Dust Policy Institute

Thank You!Thank You!