The AERO Range A700 GAS CHROMATOGRAPH The AERO Range A700 GAS CHROMATOGRAPH Dynamica GmbH Moosmattstr. 32 CH-8953 Dietikon, Switzerland P: +41 44 744 2828 F: +41 44 744 2834 Email: [email protected] Australasia Dynamica Pty Ltd Unit C3 Hallmarc Business Park Corner Centre and Westall Roads Clayton, Victoria, 3168, Australia P: +61 3 8540 5988 F: +61 3 9548 7177 Email: [email protected] Asia Dynamica (Asia) Limited Room 607, Yen Sheng Centre 64 Hoi Yuen Road, Kwun Tong Kowloon, Hong Kong P: +852 3583 1581 F: +852 3583 1580 Email: [email protected] www.dynamica-asia.com 07/2012 AERO A700 SPECIFICATION Column Oven Temperature Ambient +5°C to 420°C (increment of 1°C) Temperature Accuracy ± 0.05°C (250°C) Temperature Ramp 0.1 to 80°C / min (max. 22 ramp) Capacity 16L Sample Injection Temperature Ambient +5°C to 420°C Injection Ports Up to 3 Ports Heating Zone 3 Flow Control Mode Automatic Flow / Pressure Control Pressure 0 to 40 psi Detector Temperature Ambient +5°C to 420°C No. of Detectors Up to 3 Detectors GC Main Unit Dimensions (w x d x h) 630 x 570 x 510 mm Weight 55Kg Power Requirements AC 220 - 240V, 50Hz FID Detection Limit 5 x 10 -12 g/s (n-hexadecane) Baseline Noise 5 x 10 -14 A Baseline Drift 1 x 10 -13 A/30min TCD Sensitivity 10,000mV•ml/mg (n-hexadecane) Baseline Noise 30μV (99.999% H 2 gas) Baseline Drift 100μV/30min ECD Sensitivity 3 x 10 -14 g/ml (γ-BHC) Baseline Noise 15μV Baseline Drift 100μV/30min Radiation Source Ni 63 , 10mCi NPD Detection Limit N 5 x 10 -12 g/s (Azobenzene) P 5 x 10 -13 g/s (Malathion) Baseline Noise 2 x 10 -13 A Baseline Drift 4 x 10 -13 A/30min FPD Detection Limit S 8 x 10 -11 g/s (Parathion-methyl) P 8 x 10 -13 g/s (Parathion-methyl) Baseline Noise 8 x 10 -11 A Baseline Drift 5 x 10 -12 A/30min PID Detection Limit S 5 x 10 -12 g/s (benzene) Baseline Noise 5 x 10 -14 A Baseline Drift 1.2 x 10 -12 A/30min

Upload: others

Post on 05-Jan-2022

35 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: dynamica A700 Gas Chromatograph

The AERO RangeA700 GAS CHROMATOGRAPH

The AERO RangeA700 GAS CHROMATOGRAPH

Dynamica GmbH

Moosmattstr. 32CH-8953 Dietikon, Switzerland

P: +41 44 744 2828 F: +41 44 744 2834

Email: [email protected]

AustralasiaDynamica Pty Ltd

Unit C3 Hallmarc Business ParkCorner Centre and Westall RoadsClayton, Victoria, 3168, Australia

P: +61 3 8540 5988F: +61 3 9548 7177

Email: [email protected]

AsiaDynamica (Asia) Limited

Room 607, Yen Sheng Centre64 Hoi Yuen Road, Kwun TongKowloon, Hong Kong

P: +852 3583 1581 F: +852 3583 1580

Email: [email protected]

www.dynamica-asia.com

07/2012

AERO A700 SPECIFICATION

Column Oven

Temperature Ambient +5°C to 420°C (increment of 1°C)Temperature Accuracy ± 0.05°C (≤250°C)Temperature Ramp 0.1 to 80°C / min (max. 22 ramp)Capacity 16L

Sample Injection

Temperature Ambient +5°C to 420°CInjection Ports Up to 3 PortsHeating Zone 3Flow Control Mode Automatic Flow / Pressure ControlPressure 0 to 40 psi

DetectorTemperature Ambient +5°C to 420°CNo. of Detectors Up to 3 Detectors

GC Main UnitDimensions (w x d x h) 630 x 570 x 510 mmWeight 55KgPower Requirements AC 220 - 240V, 50Hz

FID

Detection Limit ≤ 5 x 10-12g/s (n-hexadecane)Baseline Noise ≤ 5 x 10-14ABaseline Drift ≤ 1 x 10-13A/30min

TCD

Sensitivity 10,000mV•ml/mg (n-hexadecane)Baseline Noise ≤ 30µV (99.999% H2 gas)Baseline Drift ≤ 100µV/30min

ECD

Sensitivity ≤ 3 x 10-14g/ml (γ-BHC)Baseline Noise 15µVBaseline Drift ≤ 100µV/30minRadiation Source Ni63, ≤ 10mCi

NPD

Detection Limit N ≤ 5 x 10-12g/s (Azobenzene)P ≤ 5 x 10-13g/s (Malathion)

Baseline Noise ≤ 2 x 10-13ABaseline Drift ≤ 4 x 10-13A/30min

FPD

Detection Limit S ≤ 8 x 10-11g/s (Parathion-methyl)P ≤ 8 x 10-13g/s (Parathion-methyl)

Baseline Noise ≤ 8 x 10-11ABaseline Drift ≤ 5 x 10-12A/30min

PID

Detection Limit S ≤ 5 x 10-12g/s (benzene)Baseline Noise ≤ 5 x 10-14ABaseline Drift ≤ 1.2 x 10-12A/30min

Page 2: dynamica A700 Gas Chromatograph

Dynamica’s extensive manufacturing

experience, commitment to innovation

and continuous refi nement, has resulted

in an extensive range of precision

laboratory instrumentation that fulfi lls

the challenges of the contemporary and

multifaceted laboratory environment.

From product design and research

through development to production and

distribution, Dynamica always strives to

deliver practical and innovative solutions

with dependable services to your

laboratories.

Aero A700Gas Chromatograph

Wide Range of Detector Selection for Various Applications

TCD Thermal Conductivity Detector• Generally used analysis of inorganic gases and concentrated organic

compounds.

• High quality Rhenium-Tungsten fi lament is used together with the constant fl ow control of dual column balance mode.

FID Flame Ionization Detector• Used for analysis of volatile organic compounds.

• The column fl ow can be measured directly thanks to the sealed main body design.

ECD Electron Capture Detector• The ECD is suitable for analysis of electrophilic compounds such as

chlorinated pesticide residue.

• The micro-fl ow cell design shortens stabilization time.

FPD Flame Photometric Detector• The FPD is used for analysis of organic sulphur compounds and organic

phosphorus compounds such as residual pesticides and malodorous components.

• High quality PMT is used to ensure high sensitivity.

NPD Nitrogen Phosphorus Detector• Suitable for analysis of nitrogen or phosphorus containing compounds.

• Premium grade Rubidium bead is used to ensure high sensitivity and durability.

PID Photo Ionization Detector• Suitable for analysis of aromatic compounds.

• Universal non-destructive and high sensitivity detector.

Aero A700 provides standard system for some of the most common applications as well as customized solutions to fulfi ll your requirement.

Food Additive and Pesticide Residue Analysis• Equipped with ECD to detect residual BHC, DDT, Pyrethrins in food.

• FPD/NPD is used to detect residual phosphorus containing pesticides or carbamates in food.

• FID is used to analyze additive in food such as sorbic acid, benzoic acid, etc.

Solvent Residue Analysis• Detection of residual solvent in food packaging material and drugs according to the pharmacopeia.

• Equipped with FID and combining headspace sampler.

VOC Analysis• Equipped with FID, PTV injector and a dedicated column.

• Detection of benzene toluene, xylenes and total volatile organic compounds.

Gas Analysis• For the analysis of LPG, natural gas, artifi cial gas, fermented gas, etc.

• With multifunction external event controller for automatic switching of different kinds of gas sampling valves.

Oxygenates Analysis• Specifi cally designed for the analysis of gasoline, fuel oil and ethanol containing diesel fuel.

• Equipped with FID, multiple columns with 10-port switching valve and reverse fl ow to detect alcohols and ethers.

The Aero A700 is a high performance multi-channel gas chromatograph designed for a broad range of analytical applications. It has the analytical capability and fl exibility required for laboratories performing routine analyses as well as those involved in research and development. In combination with the GS10 Autosampler, the Aero A700 offers complete automation of a sequential and unattended run of up to 110 samples.

Improved Performance with EasyFlow TechnologyWith the EasyFlow Technology, carrier-gas fl ows are automatically adjusted to compensate for the vairations of ambient temperature and pressure. This innovative technology enhances system stability and delivers constant retention time reproducibility.

Up to 18 EasyFlow channels can be installed in Aero A700. The carrier gas fl ow can be manipulated either by constant pressure mode or constant fl ow rate mode.

Single-channel or Multi-channel Confi gurations Provide Optimal Analytical CapabilityAero A700 is available with up to three channels confi gurations with a choice of capillary (split/splitless) injectors and packed-column injectors as well as a selection of six detectors.

Capillary (split/splitless) injectors are applicable to narrow bore and wide bore capillary column. The nut and seal components of the injector are gold-plated to prevent chemical reaction with sample at elevated temperature.

Packed Column Injectors are applicable to packed column or wide bore capillary column. With septum purge function, interference caused by bleeding of the septum at high temperature is minimized.

Large Column Oven with High Precision Temperature Control SystemThe column oven can accommodate 1 to 3 capillary columns with door-open protection and overheat protection, and

From product design and research

through development to production and

distribution, Dynamica always strives to

deliver practical and innovative solutions

with dependable services to your

a maximum of 10 temperature zones. Fast temperature ramping of up to 80˚C/min is achievable by using powerful fan & heating block system as well as the intelligent door-interlock mechanism.

Aero Link Software & Standalone OperationAero Link is a powerful and user friendly software specifi cally designed for the control and data processing of the Aero Series gas chromatography systems. Besides, the Aero A700 is fully equipped and capable of executing all functions in standalone mode.

User Friendly Operation and Information Rich LCD DisplayThe extra-large backlit LCD screen displays a large array of data also in graphical format. The seamless and chemical resistant keypad is designed for easy and quick selection of navigation and function features.