dynascan ds0808 quickstart guide
DESCRIPTION
DynaScan DS0808 Quickstart GuideTRANSCRIPT
Ver.1 DS0808 Quick Start Guide
1 Hardware Quick Start 1.1 Power Input and Consumption
1.1.1 Power Control Box for 100V The 100V (100~120V) Power input consists of two
cables. AC2 cable has three lines, (L/N and ground).
AC1 is for Inverter. AC1 consists of a Red line and a
black line. Please follow the instruction to setup your
power cable as below. You need two power cables to
connect the terminal and the power source.
N (Black) L (RED) Ground (Green)
AC1
AS for the detail of the cable, please refer to the table as below. AC2
AC1 (Inverter) AC2
Line Number 2 3
Descriptions Line (Red)
Neutral (Black)
Line (Red)
Neutral (Black)
Ground (Green)
Requirement 7A@110VAC (Max.) 12A@110VAC (Max.)
NOTE: The Power Cable connected to
the Power Supply is Optional.
Copyright © 2007 DynaScan Technology Corp. 1
Ver.1 DS0808 Quick Start Guide
1.1.2 Power Control Box for 220V The 220V (200~240V) Power Control box has one
AC power cable.
The requirement is 9A (Power Control Box plus
Light box).
Please follow the instruction to setup your power
cable as below.
Connect the power source and terminal with your
power cable.
N (Black) L (RED) Ground (Green)
AC2
Line Number 3
Descriptions Line (Red)
Neutral (Black)
Ground (Green)
Requirement 9A @220VAC(Max.)
AC2
NOTE: The Power Cable connected to the Power Supply is Optional.
Copyright © 2007 DynaScan Technology Corp. 2
Ver.1 DS0808 Quick Start Guide
1.2 IPC Installation
Please install: 1. Dummy VGA Monitor 2. Audio Cable as the diagram.
MouseKeyboard
COM2COM1
Line InLine OutMic In
VGA OutDVI Out
RJ-45Power USB
USB Speaker (R)Speaker (L)VolumeExternal Audio InExternal Enable Switch
8 in 1 Card Reader Tuner In, AV In, Audio In, S-Video In, Audio Out
Power Switch, Rest Button
2. Audio Cable Output the audio of Capture card to PC Please Connect the Audio Out and Line In as it shows
Use the NTSC/Pal switch connector for the
Capture Card if needed.
Power Switch, Reset Button
1. Dummy VGA Monitor Please Refer to the Appendix for more Info
Copyright © 2007 DynaScan Technology Corp. 3
Ver.1 DS0808 Quick Start Guide
1.3 Display Operation
1.3.1 Display ON / OFF Manually The Panel contains Power switch, circuit breaker and cable connectors. Steps for 100V Power Control Box
1. Turn ON/OFF the display. Please turn the Power
switch (1).
Steps for 220V Power Control Box
1. Turn ON/OFF the display. Please turn the Power
switch (1). 2. Turn ON/OFF the Inverter (2).
Copyright © 2007 DynaScan Technology Corp. 4
Reserve
2 1
Reserve
1
Circuit Breaker Circuit Breaker
Ver.1 DS0808 Quick Start Guide
Turn on: Turn on the main power switch (Power Control Box) then IPC will power on.
Turn off: Turn off the power switch of the IPC.
NOTE: If the operating system crashes, please press reset button to restart the IPC and then press power
switch again.
1.3.2 Display ON / OFF Automatically You can preset on and off for the display and IPC at a certain time through the software application. When the
preset time is up, the display will be powered on automatically, and the IPC will be triggered to power itself on too. If
you have preset the item of startup in the software application, the content of the assigned schedule or external
multimedia device will be played automatically. (Refer to the software manual for details)
NOTE: The main power switch must be always on.
Copyright © 2007 DynaScan Technology Corp. 5
Ver.1 DS0808 Quick Start Guide
1.3.3 IPC Operation You can use LCM panel to operate the IPC without keyboard and mouse.
Basic Operation:
ENTER:Enter the selected item or
save the setting
ESC:Go back or Cancel the setting
Up/Down: Move the Cursor(>)or
Change the settings
Copyright © 2007 DynaScan Technology Corp. 6
Display Power Indicator
Command Buttons 1.3.4 Put / Change Contents Insert Flash Media card*1,such as MS/MS PRO, SmartMedia, CF/MicroDrive and SD/MMC, into 8-in-1 Card
Reader for content playing.
*1 Not include a Flash Media card.
Ver.1 DS0808 Quick Start Guide
Steps
1. Save contents to a Flash Media card. (Media files must put in the root directory when you use LCM playing.)
2. Insert media card into the 8-in-1 Card Reader.
3. Choose the control item “Player Control”.
4. Choose the sub-menu “File Source”.
5. Select “All Content” to play the all media.
NOTE: 1.Refer to P.18~19 “Operation Tree of the IPC LCM” for more menu items, please. 2. For more instruction of IPC, please refer to the IPC User Manual.
Copyright © 2007 DynaScan Technology Corp. 7
Ver.1 DS0808 Quick Start Guide
1.3.5 Spin Speed Setting The spin speed of the display images. The more “X” is the faster it spins.
Steps
1. Choose the control item “Monitor System”.
2. Press Up to increase, or Down to decrease. “Fixed” means to stop spinning.
NOTE: 1.Refer to P.18~19 “Operation Tree of the IPC LCM” for more menu items, please.
2. For more instruction of IPC, please refer to the IPC User Manual.
Copyright © 2007 DynaScan Technology Corp. 8
Ver.1 DS0808 Quick Start Guide
1.4 Light Box Operation Power Button of Fluorescent Lamps
Turn ON/OFF the Light Box. Please Press the Power switch.
Circuit Breaker1.4.1 Timer Setting Panel
Operate selector
with indicator
Timer for Light Box Power indicatorDial
Knob Manual Switch
ON is Always ON
Time Setting Bracket Storage compartment OFF is Always OFF Set present time: Rotate the center knob in the arrow direction (i.e. clockwise) to set the time. The present time
can be set in 1-minute units. (For example, 16:31 as shown in the figure) Don’t rotate the knob counterclockwise. Insert the Time brackets: Two kinds of Time setting brackets are provided, ON (Gold) and OFF (Silver). The time
segmentation unit is 15 minutes.
Timer Chart
24 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
OFF time setting ON time setting
Copyright © 2007 DynaScan Technology Corp. 9
Ver.1 DS0808 Quick Start Guide
2 Function / Maintenance Introduction 2.1 AP3 Quick Operation
2.1.1 Start Program To activate AP3, click “START/Programs/ DynaScan AP3/DSPlayer to Start. Normally, the AP3 is running if PC
power on when your computers are from DynaScan. Double click and AP3 will be restored.
2.1.2 Main Menu and Functions of Buttons Four Sections on Main Menu
Section 1. Those buttons
are the main Menu of AP3
Section 2. Video Play control: This part is the control
bar for controlling the playing item
Section 3. Function operation area.
Section 4. Display monitor system.
Copyright © 2007 DynaScan Technology Corp. 10
Ver.1 DS0808 Quick Start Guide
2.1.3 Schedule Editing 5. Click to select schedule editing. 6. Set the Media type as Sequence File.
7. Drag the editing file as following picture.
8. Select the media file you need.
9. Drag the file to the box and editing schedule.
To setup the background sequence file,
1. Set the Media type as Sequence File
2. Click to select path and select the file you need. 3. Drag the file to the box as following picture.
4. Save the sequence editing file.
Copyright © 2007 DynaScan Technology Corp. 11
Ver.1 DS0808 Quick Start Guide
2.1.4 Edit Layout Presetting Layout AP3 provides seven layout settings. Click the layout you want, AP3 will load the layout into the editing section and
you can start to edit. The Preset layouts are undeletable.
Content Setting There is no content for newly made layout frames. If you do not assign any content to one frame, it will display a
black ground when playing. Click Start Run button to summon the Startup Run Setup window, and then assign
the content and the description of this content. The content with parameters to adjust will show the button beside description, and you can click it to setup.
Copyright © 2007 DynaScan Technology Corp. 12
Ver.1 DS0808 Quick Start Guide
Copyright © 2007 DynaScan Technology Corp. 13
Ver.1 DS0808 Quick Start Guide
2.1.5 Image Spin Speed Select the spin speed of the image(s) on the display screen. It is a drop-down list, and the options cannot be
changed, 8 Sec, 16 Sec, -- to 120 Sec. The 8 Sec. means the drum image takes 8 seconds to rotate a round. The
default setting is “Fixed”. This means that image(s) is displayed on the screen in a fixed position. You can choose
any of them to fit your needs.
Copyright © 2007 DynaScan Technology Corp. 14
Ver.1 DS0808 Quick Start Guide
2.2 Ground Mounting For Safety Reason, you must do the ground mounting to fix the display on the ground.
Steps
1. Stop the casters.
2. Lift the display a little up by counterclockwise turning the stoppers.
Copyright © 2007 DynaScan Technology Corp. 15
Ver.1 DS0808 Quick Start Guide
2.3 Caster Decoration Circle
1. Put the Bracket under the
base and align with the four
screw holes.
2. Use a screw driver to fasten
the bracket with four screws.
Note: You can follow the direction to setup another bracket on the opposite side of the base.
3. Fasten the decoration semicircle with
screws. Please fasten another side of
the circle with the same procedure.
4. Fasten another semicircle as
the procedure as above.
5. Setup the plastic cover as the picture shows.
Note: Please make sure that you align the tenons with the mortises.
Copyright © 2007 DynaScan Technology Corp. 16
Note: Pleas setup the center cover first as the picture shows, or you may not setup other cover properly.
Ver.1 DS0808 Quick Start Guide
3 Reference 3.1 Specifications
Model DS0808 LED Type Chip
Pitch (H x V) 2.0mm x 2.0mm
Resolution 1366 x 384 x 1 screen
Brightness > 750 cd/㎡
Color 16.7 millions
Contrast Ratio > 5000 : 1
Screen Size (Diagonal) 62” Diagonal x 2
Total Display Area (W x H) 1.36 m x 0.77 m x 2
Viewing Angle(H x V) >170 o x 120 o
Display Area (D x H) Φ0.87M x 0.77M
Physical Dimension (D x H) Φ1 M x 2.03 M
Physical Weight 350Kg
Power Supply 100~120 VAC, 50/60 Hz, 1Φ (110V), 25A or 200~240 VAC, 50/60 Hz, 1Φ (220V),15A
Color Spectrum Red: 660nm Green: 525nm Blue: 470nm
Safe Ambient Temperature From 0o to 30 o C
Fluorescent lamps (not included) Unit : Eight pieces (8), 30W, Length: 895mm
Copyright © 2007 DynaScan Technology Corp. 17
Ver.1 DS0808 Quick Start Guide
3.2 Operation Tree of the IPC LCM
Main Menu Menu Level 1 Menu Level 2 Menu Level 3 Main Menu Menu Level 1 Menu Level 2 Menu Level 3Play All Spin SpeedClose Power OnSelect Frame Power Off
Media File Adj Dis ForwardPicture File Adj Dis ReverseSequence File TemperatureSchedule File Power / MotorLayout File System Run Time
All Media System AlarmAll Picture Virtual Enc.All Content BrightnessSVideo LEDM ON/OFFAVTuner ChannelPlayPauseStopNextPrev.
VolumeOneTwoCloneTwo CloneThreeCF/MicroDriveSD/MMCMS/MSProSmartMediaHard Disk
One File --------------
Player Control
File Source ---------
Video Source -------
Play Operator -------
Layout ----------------
Content Device -----
Monitor System
Copyright © 2007 DynaScan Technology Corp. 18
Ver.1 DS0808 Quick Start Guide
Main Menu Menu Level 1 Menu Level 2 Menu Level 3 Main Menu Menu Level 1 Menu Level 2 Menu Level 3OS Protect WhiteClock Red
Country Code GreenCable BlueAntenna No Red
Input Pin No GreenDHCP Enable No BlueIP Address WhiteSubnet Mask RedDefault Gateway GreenSet BlueCancel No RedHost Name No GreenStartup No BlueStartup TimeShutdownShutdown TimeRebootReboot TimeWatchdogWatchdog TimerLeft Pos.Top PosWidthHeightBrightnessContrastGammaDVIVGA
Back LightCF/Micro DriveSD/MMCMS/MSPROSmart MediaStableUnstable
Video Out -------------
Input Type -----------
Option Setting
Test Pattern
Pure Color ----------
Level Color ----------
Tuner ----------------
Update Program----
Embedded OS-------
Display Setting ------
Window Adjust -----
Auto Run ------------
Network --------------
Watchdog------------
NOTE: For more instruction of IPC, Please refer to the IPC User Manual.
Copyright © 2007 DynaScan Technology Corp. 19
Ver.1 DS0808 Quick Start Guide
3.3 AP3 Default Settings
Click to start option settings. Default settings are shown below. Setting
Items Function \ Model DS0808 Remark
Startup
Setting
Select Model DS0808 Default setting.
Accelerator VMR9_WL Default setting.
Screen Type Screen2 Default setting.
Auto Startup Enable To auto activate AP3 when the computer starts.
Biling Record Enable User Define Activate the function to keep the log. It needs to reopen AP3 to enable the setting.
Computer ID User Define To set a computer ID number for Biling Record for easy maintenance.
VMR9_RL Frame Reversal Disable It's necessary to check it when you'd like to display a upside down content. Select VMR9_RL as accelerator and close it. Reopen AP3 to enable the setting.
Content in Sequence Preload User Define To shorten the blank interval between clips. It only supports Media File, Capture & Picture. Accelerator VMR9 _ WL supports this function.
Content in Schedule Preload User Define To shorten the blank interval between clips. It only supports Media File, Capture & Picture.
Sequence in Schedule Preload User Define To shorten the blank interval between clips. It only supports Media File, Capture & Picture.
Copyright © 2007 DynaScan Technology Corp. 20
Ver.1 DS0808 Quick Start Guide
Copyright © 2007 DynaScan Technology Corp. 21
Setting
Items Function \ Model DS0808 Remark
Monitor
System
Serial Port COM3 Select Monitor System connection port. Default setting is COM3.
Protocol Ver. Auto Select a correct monitor system edition. Default setting is Auto.
Display Adjust User Define
Forward: Move the screen clockwise.
Reverse: Move the screen counterclockwise.
Save: Save the setting.
Power Control Enable Enable
Forcefully turn ON or OFF the display power.
After Power off, you can’t power on the display until six minutes
later. This is for the safety reason. However you can power on the
display before the countdown is due by pressing the “Force Power
On”.
Warning: “Force Power On” may cause damage to the display.
Please don’t press the button unless you are sure that the display is
completely stop operating.
Outside Power Off Enable Disable
Check the checkbox to enable the setting. When the IPC is turned
off by any way except the shutdown time, such as pressing the
Power button. IPC will shut the display as well.
NOTE: For more instruction of AP3, please refer to the AP3 Software Manual.
Ver.1 DS0808 Quick Start Guide
3.4 Legal Notices Intellectual property; limited license to users
The hardware and software of our products are protected by copyr ight, t rademark, patent, and/or other inte l lectual property laws, and any unauthor ized use of the software, t rademarks containing herein may vio late such laws and the software l icense agreement. Except as expressly provided herein, DynaScan and i ts suppl iers do not grant any express or impl ied r ights to use any product re lated hardware and software.
DynaScan is registered trademark of DynaScan Technology Corp. in R.O.C and\or other countr ies. Microsoft is registered trademark of Microsoft Corp. Moonl ight is registered t rademark of Moonl ight cordless Ltd. IBM is registered trademark of IBM Corporat ion. Other t rademarks are trademarks of their respect ive owners. Disclaimer
Speci f icat ions and information contained herein are furnished for informational use only. Revisions are periodically made to the information herein; these revisions will be incorporated in later editions. Improvements or changes in the products or the programs described may be made at any time and are subject to change without notice, and should not be construed as a commitment made by DynaScan. This manual could include mistyping or typographical errors. DynaScan assumes no responsibility or liability for any errors or inaccuracies that may appear in this manual. Exclusion of Damages:
DynaScan Technology Corporat ion’s l iabi l i ty is l imi ted to the cost of repair or replacement of the product.
DynaScan Technology Corporat ion shal l not be l iable for : 1. Damages to other property caused by any defect in the product, damages based upon
inconvenience, loss of use of the product, loss of t ime, loss of prof i ts , loss of business opportuni ty, loss of goodwi l l , interference with business relat ionships, or other commercial loss, even i f advised of the possibi l i ty of such damages.
2. Any other damages, whether inc idental , consequent ia l or otherwise. 3. Any c la im against the customer by any other party.
Copyright © 2007 DynaScan Technology Corp. 22
Ver.1 DS0808 Quick Start Guide
3.5 Disposal Notices
Do not dispose of electrical appliances as unsorted municipal waste,
use separate collection facilities. Contact your local government for
information regarding the collection systems available. If electrical
appliances are disposed of in landfills or dumps, hazardous substances
can leak into the groundwater and get into the food chain, damaging
your health and well-being. When replacing old appliances with new
one, the retailer is legally obligated to take back your old appliances for
disposal at least for free of charge.
Copyright © 2007 DynaScan Technology Corp. 23
MEMO