e300 series

Upload: viet-hung-eaa

Post on 06-Apr-2018

262 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/3/2019 E300 Series

    1/24

    2006, ZTE Corporation. All rights reserved.

    E300 Series Mini-type Integrated Universal Inverter

  • 8/3/2019 E300 Series

    2/24

    2006, ZTE Corporation. All rights reserved.

    E300-2S0002/E300-2S0004

    E300-2S0007/E300-2S0015E300-4T0007/E300-4T0015

    Appearance

  • 8/3/2019 E300 Series

    3/24

    2006, ZTE Corporation. All rights reserved.

    Series

    E300Mini-typeIntegratedUniversalInverter

    Volt class

    2

    4

    220V

    380V

    Applied motor

    capacityKW0002

    0004

    0007

    0015

    0.2

    0.4

    0.75

    1.5

    Powerphase

    S

    T

    1-ph

    3-ph

    E300 -4T-0007B

    Model

    Derivative

    modelBuilt-in brakingunit and RS485communication

    B

  • 8/3/2019 E300 Series

    4/24

    2006, ZTE Corporation. All rights reserved.

    RS485 communicationinterface

    RS485-USB/

    RS323converter

    8p telephone line

    External keypadcontrol

    Input power supply

    DC brakingunit

    MotorGND

    Convenient

    maintenance andinstallation fan

    E300Introduction

  • 8/3/2019 E300 Series

    5/24

  • 8/3/2019 E300 Series

    6/24

    2006, ZTE Corporation. All rights reserved.

    PCcontrol

    interface

  • 8/3/2019 E300 Series

    7/24 2006, ZTE Corporation. All rights reserved.

    2 Wonderful appearance with compact size andwall mounting or side-by-side installation.

    Side-by-sideinstallation

    Wall mountinginstallation

  • 8/3/2019 E300 Series

    8/24 2006, ZTE Corporation. All rights reserved.

    Flexible fan cover design achieves independentinstallation and disassembly easily.

    3

  • 8/3/2019 E300 Series

    9/24 2006, ZTE Corporation. All rights reserved.

    Externalkeyboard

    Control panel as fittings can beseparated using from inverter.

    Manualoperation

    Fixed installationoperation

    4

    Externalkeyboardinterface

    Fixedinstallation

    hole

  • 8/3/2019 E300 Series

    10/24 2006, ZTE Corporation. All rights reserved.

    5HZ

    10HZ

    15HZ

    20HZ

    25HZ

    30HZ

    35HZ

    40HZ

    45HZ

    50HZ

    001 010 011 100 101000 110 111 000

    Seven Speed Freq Control5

    Parameter Set

    Freqoutput

    F3.0 F3.1 F3.2 F3.3 F3.4 F3.5 F3.6

    35 15 3 20 25 30 35

  • 8/3/2019 E300 Series

    11/24 2006, ZTE Corporation. All rights reserved.

    Adopt isolated independent duct for protectingboards avoiding dust and better cooling effect

    6

    Exothermicelectron organ

    Extract ventilatorfan design

    Embed capacitance for design ofmuch closer between exothermic

    electron organ and radiating system

    Airproof independent duct

  • 8/3/2019 E300 Series

    12/24 2006, ZTE Corporation. All rights reserved.

    T

    FWD jogfreq

    [F4.10]

    Freq

    Jog signal

    Dec time

    FWD jogfreq

    [F4.10]

    Acc time

    Dec time

    Freq

    T

    Jog signal

    Acc time

    7JOG running function satisfies jog

    working requirement for user.

  • 8/3/2019 E300 Series

    13/24 2006, ZTE Corporation. All rights reserved.

    8

    Reliable Multi-protectionover-current,overload, over-volt, short circuit etc. up to 20protection functions to ensure max effective

    protection for inverter and motor

    Short circuitShort circuit

    A

    V

    t

    t

    A

    V

    t

    t

    Over-current

    Over-volt

    Short circuitoverload feedbackprotects motor andinverter effectively.

    Overload

    Over-current

    prohibition

    Over-voltprohibition

  • 8/3/2019 E300 Series

    14/24 2006, ZTE Corporation. All rights reserved.

    Short circuit overload feedback protectsdriving equip and inverter effectively.

    When shortcircuit overload,inverter warns

    and pauses loadpower supply.

    Shortcircuit

    Safe andReliable

  • 8/3/2019 E300 Series

    15/24 2006, ZTE Corporation. All rights reserved.

    9Three multi-function terminal X1-X3 can be set freely

    Relay contactor outputs TA,TB,TC,OC all can be

    programmed and twelve functions for choice

    Convenient for system integration.

    Appliedsystem

    integration equip

  • 8/3/2019 E300 Series

    16/24 2006, ZTE Corporation. All rights reserved.

    10Prohibiting REV function ensures not to switch

    to REV runningeven any signal as fans orpumps which may cause REV problem.

    REV incipient faultREV maycause fans/ pumps impeller

    loose that may lead to unparallel

    impeller running, evenmechanical accident.

    Parameterset: REV

    avoidanceis valid

  • 8/3/2019 E300 Series

    17/24 2006, ZTE Corporation. All rights reserved.

    Runningindicator

    light

    Return

    Up

    Set

    Down

    LEDdisplay

    data unit

    Panelpotentiometer

    Replacement

    Run, stop, reset

    Control Panel

  • 8/3/2019 E300 Series

    18/24 2006, ZTE Corporation. All rights reserved.

    Application Case-for engraving machine

    Powersupply

    PC control

    RS485 converter

    Engravingmachine

  • 8/3/2019 E300 Series

    19/24 2006, ZTE Corporation. All rights reserved.

    M otor

    Ta

    Tb

    Tc

    U

    W

    V

    R

    S

    T

    CM AO

    CM

    Failure w a rning ou tpu t

    3-hower

    ppl

    E

    X1

    X2

    X3

    CM

    Program m ab leinp ut term ina l

    10V

    AI

    PBExterna l b ra king resisto r

    Earth

    3-Ph b rea ker

    PP

    24V A uxilia ry D C p ow er supp ly

    0~10V0~20m AFreq setting

    CM

    FWDFW D

    E

    OC

    CM

    O p en circu it collec tor ou tp ut

    V oltm eter0~10V

    Basic Wiring

    M

  • 8/3/2019 E300 Series

    20/24 2006, ZTE Corporation. All rights reserved.

    E300-2S0002/E300-2S0004

    E300-2S0007/E300-2S0015E300-4T0007/E300-4T0015

    W1W

    H1

    H

    D

    W1W

    D

    HH1

    W1 W H1 H D Screw

    spec67.5 81.5 132.5 148 134.5 M4

    W1 W H1 H D Screwspec

    86.5 101.5 147.5 165 154.5 M4

    Dimension

  • 8/3/2019 E300 Series

    21/24 2006, ZTE Corporation. All rights reserved.

    Rated volt and freq 3-Ph4T****380V 50/60 Hz 1-Ph2S****220V 50/60 Hz

    Inp

    ut

    Permissiblevolt range

    320V ~ 460V 170V ~ 270V

    Volt 0 ~ 380V 0~220V

    Freq 0~1000 Hz

    Output

    Overload endurance 110% for long-term150% for 1m 180% for 2s

    Control mode V/F control

    Analogueterminal input

    0.4% of max output freqFreqsetting

    Resolution Digital set 0.1 Hz

    Analogue input Within 0.4% of maximum output freqFreq

    Precision Digital input Within 0.1% of setting output freq

    Torque boost Manual set: 0.0~20.0% of rated outputControl

    Cha

    racteristics

    V/F

    control

    Autocurrent / volt

    limit

    It will check motor stator current and volt automatically based on

    special arithmetic to control within allowable range to ensure

    minimum failure during acc/ dec or stable running.

    Product Specification Data

  • 8/3/2019 E300 Series

    22/24 2006, ZTE Corporation. All rights reserved.

    Multi-speed controlSeven programmable multi-speed control, three multi-speed control

    terminal

    RS485 communication

    E300B

    Standard built-in RS485 interface, RS485 communication protocol

    and MODBUS for choice

    Analogue input Panel potentiometer setting, DC volt 010VDC current 020mA

    Freqsetting Digital input

    Operation panel settingRS485 interface setting, UP / DW terminal

    control

    Relay and OC

    out ut

    One OC output and one relay output (TA, TB, TC) as many as 9

    ty es of choiceOutput

    signal Analogue

    out utOne 0~10V volt signal

    Acc /dec time setting 0.1600s continuous setting, S curve and linear mode for choice

    DC braking Action freq 0~500.0 Hz, action time 0~20.0 S

    Low noise runningCarrier wave freq 1.5 KHz ~ 12.0 KHz continuous adjustments to

    ensure the lowest motor noise.

    T

    ypicalFunctions

    Running functionUpper and Lower freq setting, reversal operating restriction, RS485

    communication, freq increasing/decreasing control etc.

    Running state

    Output freq, current and voltmotor rotate speedfreq setting,

    module temperature, analog I/ODisplay

    Operationpanel

    display WarningLast four times failure record, output freq, current, volt and DC volt of

    last fault trip for running parameter record

    Protection / warning function Over current, over volt, under volt, overheating, short circuit etc.

  • 8/3/2019 E300 Series

    23/24

    2006, ZTE Corporation. All rights reserved.

    Application

    E300 series not only applies in kinds of light industry as textile, transmissionetc., but also applies in various high speed applications, such as mill, engraving

    machine, centrifuge etc. with output frequency reaching 1000 Hz.

    E300

  • 8/3/2019 E300 Series

    24/24

    The End