early detection of tube support degradation in feedwater heaters

31
Early detection of Tube Support Degradation in Feedwater Heaters Presentation to the 2013 Feedwater System Reliability Improvement Meeting January 21-24, 2013 Presented By: Steven Schaefer Authored By: Steven Schaefer & Jacob Endres

Upload: gaille

Post on 07-Jan-2016

43 views

Category:

Documents


2 download

DESCRIPTION

Early detection of Tube Support Degradation in Feedwater Heaters. Presentation to the 2013 Feedwater System Reliability Improvement Meeting. Presented By: Steven Schaefer Authored By: Steven Schaefer & Jacob Endres. J anuary 21-24, 2013. INTRODUCTION. What is ‘Tube Support Degradation’ ? - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Early detection  of Tube Support  Degradation in Feedwater Heaters

Early detection of Tube Support Degradation inFeedwater Heaters

Presentation to the 2013 Feedwater System Reliability Improvement Meeting

January 21-24, 2013

Presented By: Steven SchaeferAuthored By: Steven Schaefer & Jacob Endres

Page 2: Early detection  of Tube Support  Degradation in Feedwater Heaters

2

INTRODUCTION

• What is ‘Tube Support Degradation’ ?• Erosion of the carbon steel tube support(s) in Feedwater Heaters

• What causes Tube Support Degradation ?• Steam passing between the tube OD and the TSP hole ID

• Why is important that it is identified early?• Large numbers of tubes can be left unsupported which can lead to multiple failures from

fatigue or a plant excursion

• Involves Costly and Timely design review, procurement and replacement

• Can identify associated damage to FWH shell which could lead to catastrophic failure

• How is it typically first identified?• When the TSP signals are almost totally missing

• What are the precursors that can be identified early?• TSP signals at the same axial location that appear to be smaller then normal

• Low Frequency absolute deposit signals on one side of the TSP

Page 3: Early detection  of Tube Support  Degradation in Feedwater Heaters

3

Goals of Tubing Inspection

• Primary Goals• Condition Assessment

• Condition of each tube inspected

• Condition of the overall HX

• Component Reliability & Operability

• Identify potential failures before they occur to ensure continuous operation between inspections

• Not only for the next cycle but more importantly for long term operation

• Challenges• Probability of Detection (POD)

• Sizing Accuracy

• Schedule

• Cost

Page 4: Early detection  of Tube Support  Degradation in Feedwater Heaters

4

Standard Inspection Technique - Bobbin

• Multifrequency Bobbin Coil Inspection• Advantages

• Inspection Speed (as high as 80ips)

• Cost

• Basic equipment and software

• High sensitivity & POD for ‘Typical’ damage mechanisms

• Dis-Advantages• Detection of Circumferential Cracking

• Accurate sizing of certain volumetric conditions

Page 5: Early detection  of Tube Support  Degradation in Feedwater Heaters

5

Detection Of TSP Degradation

• Early Signs That Identify TSP Degradation/Erosion May Be Present

• Changes from Nominal TSP Signatures on Low Frequency Absolute Channel• A Change or Shift of the phase angle of the TSP signal• Lower Amplitude (voltage) TSP signatures identified on Low Frequency Absolute

Low Sensitivity strip chart• In extreme cases, a completely missing TSP signal where one is expected• Deposit like drift on either side of the TSP signal • Any of the above occurring repeatedly at the same axial TSP location in one area,

usually near an extraction steam inlet or drain cooler inlet• May be found in the condensing zone or the drain cooler• May be found in Low, Intermediate or High Pressure FWH’s• Eroded pieces of internals, such as tie rod shrouds, found in the heater drain

or down steam from the FWH drain• FWH shell erosion near the extraction steam inlet(s)

Page 6: Early detection  of Tube Support  Degradation in Feedwater Heaters

6

Accurate Sizing Of TSP Degradation

• Sizing of TSP erosion with Bobbin Probe Technique • There is no accurate sizing technique possible with Standard Bobbin Probe

Technique• This is due to the amount and proximity of the remaining TSP material to the tube

OD, the type of erosion (straight cut or tapered) and the amount of deposits near or under the TSP

• In extreme cases a piece of the remaining ligament can be all that is in contact giving a false indication of actual ‘Support’ from a TSP

• The TSP signal amplitudes can be documented and categorized by voltage for comparison with future inspections but only for general trending

• Array Coil Technology is being developed for a more accurate measurement technique

• While this could give a more accurate sizing technique it will mean additional cost, analysis and schedule time that must be built into the budget and outage schedule

Page 7: Early detection  of Tube Support  Degradation in Feedwater Heaters

7

Typical Bobbin Coil

Page 8: Early detection  of Tube Support  Degradation in Feedwater Heaters

8

Bobbin Coil Sensitivity

Page 9: Early detection  of Tube Support  Degradation in Feedwater Heaters

9

Eroded Areas Around Tubes

Page 10: Early detection  of Tube Support  Degradation in Feedwater Heaters

10

Eroded Areas Around Tubes

Page 11: Early detection  of Tube Support  Degradation in Feedwater Heaters

11

Eroded Areas Around Tubes

Page 12: Early detection  of Tube Support  Degradation in Feedwater Heaters

12

Tubesheet Map of Erosion at TSP

Horizontal U-Tubed single zone FWH with extraction steam inlets at 12 o’clock.The red tubes indicate tubes recording possible TSP degradation while the blue tubes were inspected with no damage of any type recorded.

Page 13: Early detection  of Tube Support  Degradation in Feedwater Heaters

13

Internals Drawing of Erosion at TSP

Page 14: Early detection  of Tube Support  Degradation in Feedwater Heaters

14

ET Response of Nominal TSP

Page 15: Early detection  of Tube Support  Degradation in Feedwater Heaters

15

ET Response of Eroded TSP

Page 16: Early detection  of Tube Support  Degradation in Feedwater Heaters

16

ET Signal Response Variations

Proximity of Tube OD and actual TSP hole

Page 17: Early detection  of Tube Support  Degradation in Feedwater Heaters

17

ET Signal Response Variations

Remnants of TSP ligaments that can give small but false signals of supports

Page 18: Early detection  of Tube Support  Degradation in Feedwater Heaters

18

ET Signal Response Variations

Large amounts of deposits or magnetite can alter ET response

Page 19: Early detection  of Tube Support  Degradation in Feedwater Heaters

19

Early Detection is Critical

• Early Detection is Critical• Allows for early planning of FWH replacement or temporary repairs

• Plan more frequent inspections to trend TSP signals• Indicates present FWH design may not be adequate for steam flow

• Review FWH specifications vs. design steam flow• Review flows associated with power up-rate (past, present & future)

• Indicates higher potential for tube failure(s)• Unsupported spans can lead to tube failure from fatigue over time• Unexpected event like a plant trip or water hammer can lead to multiple tube failures at one

time• Indicates FWH shell has high potential for erosion and failure

• Shell should be inspected for thinning with UT in areas of TSP erosion and near extraction steam inlets

• If TSP erosion is in the drain cooler• FWH level may be operating below desired level

• Review of operational data to determine typical operational level• Verify level indicator is operating correctly and is accurate

• Drain cooler snorkel could be damaged or improperly designed• Drain cooler end plate holes could be eroded and allowing steam intrusion

Page 20: Early detection  of Tube Support  Degradation in Feedwater Heaters

20

Reporting of TSP Degradation

• As stated earlier, TSP hole sizing is inaccurate with standard bobbin probe technique

• Signal amplitude changes with proximity to TSP or remnants of TSP

• Simple trending by percent of full nominal response by 100%, 80%, 60%, 40%, 20% and <20% of signal voltage

• This gives a simple signal voltage % to track overall TSP condition• Example: Nominal TSP somewhere near the middle of the bundle is set to

10.00 volts then: 9.00 volts and greater = 100%, 7.00 to 8.99 volts = 80%, 5.00 to 6.99 volts = 60%, 3.00 to 4.99 volts = 40%, 1.00 to 2.99 volts = 20% & <1.00 volts = <20%; this allows a tolerance and gives a general condition

• Again, this is a general condition and your actual mileage may vary, but it allows for trending and assessing the overall stage of progression and the ability to set a timetable for replacement or immediate repairs until a replacement can be completed

Page 21: Early detection  of Tube Support  Degradation in Feedwater Heaters

21

TSP Erosion Sized by General Percent

Actual Inspection with TSP degradation quantified by general percent

Page 22: Early detection  of Tube Support  Degradation in Feedwater Heaters

22

Autopsy of FWH - Inverted

Page 23: Early detection  of Tube Support  Degradation in Feedwater Heaters

23

ET Response vs. Actual TSP

Actual ET results utilizing general voltage percent

Actual removed TSP from Drain Cooler

Page 24: Early detection  of Tube Support  Degradation in Feedwater Heaters

24

Tube-Pro 3D Modeling

Single Zone Feedwater Heater with two Extraction Steam Inlets

Impingement Plates Below Extraction Steam Inlets

Page 25: Early detection  of Tube Support  Degradation in Feedwater Heaters

25

Tube-Pro 3D Modeling

Single Zone Feedwater Heater with two Extraction Steam Inlets

Tubes with TSP Degradation Identified on Tubesheet

Page 26: Early detection  of Tube Support  Degradation in Feedwater Heaters

26

Tube-Pro 3D Modeling

Single Zone Feedwater Heater with two Extraction Steam Inlets

Locations at Tube Supports that indicated TSP Degradation

Page 27: Early detection  of Tube Support  Degradation in Feedwater Heaters

27

Tube-Pro 3D Modeling

Single Zone Feedwater Heater with two Extraction Steam Inlets

Close up of area showing TSP Degradation

Page 28: Early detection  of Tube Support  Degradation in Feedwater Heaters

28

Summary

• What is ‘Tube Support Degradation’ ?• Erosion of the carbon steel tube support(s) in Feedwater Heaters.

• What causes Tube Support Degradation ?• Steam passing between the tube OD and the TSP hole ID.

• Why is important that it is identified early?• Large numbers of tubes can be left unsupported which can lead to multiple failures from

fatigue or a plant excursion

• Involves Costly and Timely design review, procurement and replacement

• Can Identify associated damage to FWH shell which could lead to catastrophic failure

• How is it typically first identified?• When the TSP signals are almost totally missing.

• What are the precursors that can be identified early?• TSP signals at the same axial location that appear to be smaller then normal.

• Low Frequency absolute deposit signals on one side of the TSP.

Page 29: Early detection  of Tube Support  Degradation in Feedwater Heaters

29

References

• Some pictures and slides were used with permission of the author from a previous presentation Titled: “Comparison of Degraded Baffle Signal Methodology to Actual Degraded Baffles – Results in: a Better Methodology”, Perry Holzman, 2010 EPRI BOP HX NDE Conference

Page 30: Early detection  of Tube Support  Degradation in Feedwater Heaters

Steven SchaeferManager, BOP Services

ET Level III QDA, ASNT ET III BOPAnatec Division

Phone: 949-498-3350 Mobile: 860-885-4695

[email protected]

Jacob EndresProject ManagerET Level III QDAAnatec Division

Phone: 949-498-3350 Mobile: 940-727-1126

[email protected]

Darren HoweVice President

ET Level III QDAAnatec Division

Phone: 949-498-3350 x202Mobile: 949-300-2173

[email protected]

Chris J. SpeasV. P. - Business DevelopmentET Level III QDA, ASNT ET III

Anatec-LMTPhone: 949-498-3350 x302

Mobile: [email protected]

For Additional Information

30

Page 31: Early detection  of Tube Support  Degradation in Feedwater Heaters

Early detection of Tube Support Degradation inFeedwater Heaters

Presentation to the 2013 Feedwater System Reliability Improvement Meeting

January 21-24, 2013

Presented By: Steven SchaeferAuthored By: Steven Schaefer & Jacob Endres