Page 1: EC Motor Fan Coil Units of temperzone IMD Series fan coil units. All temperzone IMD fan coil units are right handed, i.e. when facing the discharge side of the unit, the water and

EC Motor Fan Coil UnitsIMD-Y Series 450 – 2350 l/s

Page 2: EC Motor Fan Coil Units of temperzone IMD Series fan coil units. All temperzone IMD fan coil units are right handed, i.e. when facing the discharge side of the unit, the water and

2 3

Company Profile

Temperzone Limited is a leading manufacturer and distributor of quality air conditioning and ventilation products throughout the Western Pacific Rim. Corporate Head Office is located in New Zealand with factories in Auckland and Sydney. A network of offices, warehouses and distributors provide local support and representation in Australasia, South East Asia and China.

temperzone’s aim is to provide the most competitively priced, reliable and efficient air conditioning equipment available to the international market. A privately owned company, temperzone Holdings Ltd, is the parent company of temperzone ltd (est.1956) in Auckland and temperzone Australia pty ltd in Sydney.

The wide range of temperzone products are manufactured in Auckland for markets in Australasia and Asia. This range includes air distribution items and fans for New Zealand. The Sydney headquarters acts as both a distribution centre and manufacturer of customised and larger standard air conditioning units specifically for Australia. temperzone’s Asia Regional Head Office is located in Singapore. The combined group operations employ over 500 staff.

GENERALFan coil units are an integral part of an overall air conditioning system where the energy transfer medium (i.e. chilled or hot water) is circulated by a central plant facility.

temperzone offers an extensive range of ducted fan coil units. A variety of options and accessories are available to meet most air conditioning requirements.

Low operating cost, energy efficient fan motors are used in all units. Easy installation and maintenance add to the cost effectiveness of temperzone IMD Series fan coil units.

All temperzone IMD fan coil units are right handed, i.e. when facing the discharge side of the unit, the water and electrical connections are on the right hand side.

TYPICAL APPLICATIONSOffice Buildings IMD units are ideally suited to office building applications where false ceiling space is available and medium static pressure and ductwork is a consideration.

Airport Terminal Buildings temperzone fan coil units are gaining worldwide popularity in airport terminals. These complexes generally consist of a number of areas with very diverse occupancy and capacity requirements.

Hospitals The majority of hospital rooms must have a separate and independent air conditioning system. This is to avoid bacterial cross contamination. temperzone fan coil units have been used successfully in these applications.

STANDARD FEATURESDrain TrayThe drain tray on models IMD 95–280 are made of plastic for complete corrosion protection; IMD 420 and 550 are powder coated galvanised steel. Drain trays are removable for ease of cleaning and have a built-in slope to ensure condensate water drains freely without ponding.

MotorsHigh efficiency electronically commutated (EC) motors are fitted as standard on all units. Motors can be operated on three speeds (site changable) or 0-100% capacity using a 0-10V dc signal supplied by a BMS or sophisticated controller. The motors are resiliently mounted, self aligning and oiled for life.

FansQuiet low line, centrifugal type, double width, statically and dynamically balanced, multi-bladed impellers are used. The position and shape of the fan blades and housing has been developed after extensive testing to achieve minimum noise levels while maintaining a smooth pressure vs air flow curve.

CoilsCoils are manufactured in rifled copper tubing. All coils are thoroughly tested to 2100 kPa. Coil rows are staggered for maximum heat exchange. Three different coil configurations are available – refer table below.

The coil fins are manufactured as a continuous plate, die formed from epoxy coated aluminium with a smooth corrugated surface, specially designed to overcome and prevent lint build up. The coil fins are mechanically bonded to the copper tubing which results in a rigid assembly and provides a permanent metallic contact between fins and tube for maximum heat transfer.

CasingThe casing is manufactured from high quality galvanised steel and internally insulated.

InsulationClosed cell foam insulation has been used in the cabinet to ensure no particles are introduced into the air stream. The insulation is foil faced and meets the fire test standards AS 1530.3 (1989) and BS 476 parts 6 and 7.

MountingThe IMD unit can be mounted rigid, or using the optional spring mounting brackets which minimise transfer of vibration.

ELECTRICAL BOXWiring from the motors terminate in a terminal block in a sheetmetal enclosed electrical box. The box is supplied on the same side as the water connections, but can be changed on site to the opposite side.

ELECTRIC HEATElectric Heat is available with some coil configurations (refer table right). Elements are factory mounted within the unit. A fan run-on timer (for heat dissipation) is included. These units are supplied complete with safety cutouts required to meet AS/NZS 3350.2.40 1997.

ACCESSORIES1. Filter Box integrated with return air spigot – filter is 13 mm thick, washable and rated EU2. (Not for use in Australia)

2. Spring Mounting Kit.

3. Supply and return air plenums (IMD 95–280).

4. Control switches (IMD 95–280) – on/off and 3 speed rotary switches mounted in a standard or architrave type flush plate.

WIRINGThe electrical supply required (including voltage fluctuation limits) is: 1 phase 200–252 V a.c. 50 Hz with neutral and earth. Each IMD unit is fully wired ready to accept the main power supply.

Note: When installed with electric heat the IMD 135–420 units require a three phase power supply of 342–436 V a.c. 50 Hz.

ORDER DETAILCoil Options:1 - One row coil for heating4 - Four row coil for cooling4/1 - Four row cooling / one row heating4E - Four row cooling coil + electric heatE - Electric heatNote: Please specify on your order the size, fan motor type and coil option using the above codes.

Examples: IMD 135Y-4/1 IMD 210Y-4E

Temperzone’s Fan Coil History

Temperzone have been manufacturing chilled water fan coil units for more than 45 years.

Prior to the development of temperzone’s EC motor fancoils, units had all been manufactured with fixed single speed or multi-speed PSC motors. Any changes in the cooling or heating performance had been solely on the basis of varying the water flow by way of a 2-way or 3-way water regulating/modulating valve. With the indoor fan running on a constant speed this left considerable room for improvement in designing higher efficiency models.

It is time now to take a step forward with the new IMD “Y” version with EC (Electronically Commutated) motors. EC motors allow for the air flow to be controlled over a wider range either by the multiple speeds that are available or by the use of a 0 – 10V dc variable signal.

Speeds as high as 1500 rpm and as low as 500 rpm are available ether by dip switch selection if multi-speed is preferred or by the variable voltage signal (a signal isolator is required between the controller output and the unit input if the variable control is desired).

IMD-Y Fan Coil Units

Coil Option

SeriesSize

Key Features• Energy Efficient EC Motor

• Significant Energy Savings

• Pressure Independent Fan Operation

• On-site Adjustable Fan Air Volume Controller

• Remote Fan Air Volume Adjustment Capability from BMS.

IMD *Y-

Page 3: EC Motor Fan Coil Units of temperzone IMD Series fan coil units. All temperzone IMD fan coil units are right handed, i.e. when facing the discharge side of the unit, the water and

4 5

VAVFor the last 40 years virtually all fan coil units have operated with a constant fan speed and therefore constant air volume (CAV). Temperature changes in these units were achieved by the water valve, i.e. varying the water volume. With this design, energy was wasted due to fans constantly running at full speed, regardless of the requirement of the thermal zone served.

With temperzone’s new range of VAV fancoil units, varying air volume results in greater efficiency.

ControlsThe new EC motor version IMD units allow for several methods of control allowing great flexibility to meet the demands of modern buildings expectations. The fan speed could be adjusted for instance as the first step of capacity control before adjusting water flow.

Three Speed SelectionThe fans can be controlled just like their predecessors using three speed selection, high, medium and low. This option is selectable by dip switch and then by using further dip switch settings to select from the available speed ranges that are most suitable for the application.

PotentiometerThe fans could also be controlled by the fitting of a potentiometer to preset the required speed. This will be particularly useful during onsite commissioning to adjust to obtain the desired air flow.

Indoor Fan SpeedThe fan can be switched ON by selecting High, Medium or Low fan speed on the terminal block, or via BMS.

The fan speed can be controlled in two ways: ‘Stepped’ or ‘Continuously Variable’.

Dip switches 1 to 5 and 7 on the Analogue Level Controller (ALC) determine the minimum and maximum fan speeds. The same ‘Minimum rpm’ and ‘Maximum rpm’ settings apply to both the ‘Stepped’ and ‘Continuously Variable’ control methods.

There are two fan speed ranges available using dip switch 7:

• Low, which is the default for low profile IMDL units &

• High, which is the default for in higher air flow IMD units.

The default settings for max. fan speed and fan speed range are highlighted on the Wiring Schematic.

1. Stepped (3 Speed)

If using a 3-speed selection switch, the medium speed will always be half way between the maximum (High) and minimum (Low) speeds – as selected using the DIP switches 1 to 5.

2. Continuously Variable (0-10V Control)

If using a variable 0–10V dc signal (from a BMS or sophisticated controller) the fans will not operate until a signal above 1.6V is received and will then start at the minimum voltage/speed set using DIP switches 1 to 5.

A voltage below 1.6V DC applied across the ‘0V’ and the ‘0-10V’ input terminals will activate fan run on and after this the fan will stop.

A control voltage of 2V will cause the fan to run at the ‘Min. rpm’ speed. A 10V DC signal will run the fan at the ‘Max. rpm’ speed. Control voltages between these two limits (2V –10V) can be used to achieve any desired speed between ‘Min.’ and ‘Max.’ rpm in a linear relationship so 6V gives you ‘Med.’ (halfway between ‘Min.’ and ‘Max’).

Note: Only one control method must be connected at any one time; either Stepped 3 Speed control or Continuously Variable 0-10V dc, not both.The fan will run on at Low speed when there is no input signal for either 40 or 120 seconds, dependant on the DIP switch 6 setting, before stopping. If electric heat is fitted, ensure that DIP switch 6 is set for 120 seconds.

BMSMany modern buildings these days have Building Management Sytems (BMS) and it is desirable to control the fan speed variably to meet the building’s load demands. The unit can accept a 0-10Vdc signal from the BMS or other sophisticated controller. This option is again selectable by dip switch and likewise so is the allowable speed range.

The BMS can be programmed to achieve various beneficial functions such as; maintaining high air flow when on heating first thing in the morning to avoid stratification within the space, reducing the air flow down to say 50 to 60% as a capacity control method prior to adjustment of the water flow.

EC MotorsBrushless EC motors within the fan coil units provide a cooler running motor emitting less heat into the supply air. This is achieved as energy savings reduce the fan power to almost a quarter of a comparable PSC motor.

The life expectancy of an EC motor can be up to twice as long as a comparable PSC motor due to functions such as the soft start which eliminate stress to the mounting bracket or hardware. This improved life expectancy further benefits the building owner by a reduction in maintenance costs.

There is a “Fault” output on the EC Motor controller that can be used to drive external Fault relay (201-000-105) which provides “Dry Contact” terminals that can be used to signal a motor or controller overload fault.

Model IMD 95Y IMD 135Y

IMD 170Y

IMD 210Y

IMD 280Y

IMD 420Y

IMD 550Y

Nominal Air Flow (l/s) * 450 600 750 900 1250 1800 2350

Fan type forward curved centrifugal double inlet double width

No. of fan scrolls 1 1 1 2 2 2 2

Motor type Electronically Commutated (EC) DC direct drive

Power Source ** 1 Phase 230 VoltAC 50 Hz

No. of motors 1 1 1 1 1 2 2

Motor Rating (W) 600 900 1250 1250 1250 1250 (x2) 1250 (x2)

Full Load Amps (A) **** 3.3 4.9 6.8 6.8 6.8 9 x 2 (18) 9 x 2 (18)

Optional Electric Heating (kW) ** 4 6 6 9 9 12 18

Heat Exchanger type epoxy aluminium corrugated plate fins to expanded rifled copper tube

Cooling/Heating Medium chilled water or hot water

Coil Rows Options (4 rows cooling) or (4 rows cooling + 1 row heating) or (4 rows cooling + electric heat)

Finish zinc galvanised steel

Test Pressure 2100 kPa

Connection Sizes Cooling Coil (mm) 25 BSP Male (1”) 32 BSP Male (1 1/4”)

Connection Sizes Heating Coil (mm) 15 BSP Male (1/2”)

25 BSP Male (1”) 32 BSP Male (1 1/4”)

Air Filter Type *** washable G2 / EU2

No. of Air Filters 1 1 1 1 2 2 2

Air Filter Size (mm) 593 x 275 x 13

767 x 275 x 13

914 x 275 x 13

1064 x 275 x 13

593 x 345 x 13

685 x 415 x 13

712 x 542 x 13

Static to allow for Air Filter (Clean) at Nominal Air Flow (Pa) *** 55 60 60 63 63 68 63

Static to allow for wet surface coil (Pa) 28 30 32 34 36 32 32

Weight (4/1 row unit, incl water) (kg) 49 50 64 66 94 158 183

Nett Weight (4/1 row unit, excl water) (kg) 45 45 59 60 86 145 166

Shipping Weight approx. (kg) 48 48 62 63 96 170 196

Notes: * With no filters fitted and with a dry coil surface and 100Pa external resistance** Voltage fluctuation limits 200 - 252 V. IMD 135–550 electric heat models require a 3 phase power supply, 342–436 V a.c 50 Hz.*** Standard filters not to be used in Australian market (see note on page 15)****Excluding Electric Heat

Summary of ChoicesSize 95 / 135 / 175 / 210 / 280 / 420 / 550

Cooling and Heating Coil

Configurations

4 Rows Cooling

4 Rows Cooling + 1 Row Heating

4 Rows Cooling + Electric Heat

Fan Run On Timer EC motor driver has in built run on timer for all models 50s approx

Handing Right (Standard) / Left

SpecificationTECHNOLOGY

Page 4: EC Motor Fan Coil Units of temperzone IMD Series fan coil units. All temperzone IMD fan coil units are right handed, i.e. when facing the discharge side of the unit, the water and

6 7

IMD 95Y

Cooling Capacity kWEntering Air Temperature 23.0°C db 17.0°C wb Nominal Air Flow 450 l/s

Coil Rows Water Flow l/s

Water Pressure Drop kPa

Entering Water Temperature °C5 6 7 8 9

Total Sensible Total Sensible Total Sensible Total Sensible Total Sensible

40.30 7.0 7.8 5.9 7.2 5.6 6.7 5.4 6.1 5.2 5.4 4.90.50 17.6 9.3 6.5 8.5 6.2 7.9 5.9 7.1 5.6 6.5 5.30.70 32.4 10.2 6.9 9.3 6.5 8.6 6.2 7.8 5.9 7.0 5.6

Heating Capacity Electric Heating Option 4 kWEntering Air Temperature 21.0°C db Nominal Air Flow 450 l/s

Coil Rows Water Flow l/s

Water Pressure Drop kPa

Entering Water Temperature °C

40 45 50 55 60 65 70 75 80

10.08 5.1 2.9 3.7 4.4 5.2 6.0 6.7 7.5 8.3 9.00.14 14.9 3.4 4.3 5.2 6.1 7.0 7.9 8.8 9.7 10.60.20 28.6 3.7 4.7 5.7 6.6 7.6 8.6 9.6 10.5 11.5

IMD 135Y

Cooling Capacity kWEntering Air Temperature 23.0°C db 17.0°C wb Nominal Air Flow 600 l/s

Coil Rows Water Flow l/s

Water Pressure Drop kPa

Entering Water Temperature °C5 6 7 8 9

Total Sensible Total Sensible Total Sensible Total Sensible Total Sensible

40.30 8.5 9.2 7.6 8.9 7.2 8.2 6.9 7.5 6.7 6.8 6.40.45 17.2 11.3 8.2 10.5 7.8 9.6 7.5 8.8 7.2 7.8 6.80.60 28.9 12.5 8.7 11.5 8.3 10.6 7.9 9.6 7.5 8.7 7.1

Heating Capacity Electric Heating Option 6 kWEntering Air Temperature 21.0°C db Nominal Air Flow 600 l/s

Coil Rows Water Flow l/s

Water Pressure Drop kPa

Entering Water Temperature °C

40 45 50 55 60 65 70 75 80

10.09 8.2 3.7 4.7 5.6 6.6 7.6 8.6 9.5 10.5 11.50.14 17.7 4.3 5.4 6.5 7.7 8.8 9.9 11.0 12.2 13.30.18 27.6 4.6 5.8 7.0 8.2 9.4 10.6 11.8 13.0 14.2

Supply Air Outlet

Fan SpeedVolts

Sound Power

SWL dB(A)

Octave Band Frequency Hz125 250 500 1K 2K 4K

Sound Power Levels (SWL) dB

7.3 63 62 60 60 59 55 538.3 68 65 66 64 64 60 5910 73 72 72 68 68 66 64

Supply Air Outlet

Fan SpeedVolts

Sound Power

SWL dB(A)

Octave Band Frequency Hz125 250 500 1K 2K 4K

Sound Power Levels (SWL) dB

8.3 62 63 61 58 56 54 529.3 67 66 66 63 61 59 5810 73 72 72 68 68 65 64

Air Handling Air Handling

Dimensions Dimensions

Sound Levels Sound Levels

ELECTRICALACCESS PANEL

WATERCONNECTIONS:25 BSP MALE(HEATING 15 BSP MALE)

585

770OVERALL

85

360 OA

650HANGING CENTRES

225 285

60

15

DRAIN 19 OD

120

15

630 OA

MOUNTINGSLOTS 20 x 9

530HANGINGCENTRES

600OPTIONAL

SPRING MTGCENTRES

135

ELECTRICALCONDUIT HOLES

6060

FAN ACCESS VIAREMOVEABLE BASE

& DRAIN TRAY,OR VIA TOP PANEL

ACCESSPANEL

685SPRING MTG CTRS

400

OPTIONALFILTER BOX WITHFILTER ACCESSEACH SIDE

135ELECTRICAL

ACCESS PANEL

760

945OVERALL

85

360 OA

825HANGING CENTRES

225 285

60

15

DRAIN 19 OD

120

15

630 OA

MOUNTINGSLOTS 20 x 9

530HANGINGCENTRES

600OPTIONAL

SPRING MTGCENTRES

ELECTRICALCONDUIT HOLES

60ACCESSPANEL

860SPRING MTG CTRS

400265

WATERCONNECTIONS:25 BSP MALE(HEATING 15 BSP MALE)

60

OPTIONALFILTER BOX WITHFILTER ACCESSEACH SIDE

135

FAN ACCESS VIAREMOVEABLE BASE

& DRAIN TRAY,OR VIA TOP PANEL

Note: Airflows are for dry coil. Reduce airflow by 10% in high moisture removal conditions.

Airflows given are for IMD-Y units without filter installed.

Refer back page for filter pressure drop.

Note: Airflows are for dry coil. Reduce airflow by 10% in high moisture removal conditions.

Airflows given are for IMD-Y units without filter installed.

Refer back page for filter pressure drop.

100 200 300 400 500 6000

100

200

300

400

500

AIR VOLUME (l/s)

AV

AIL

AB

LE E

XTE

RN

AL

PR

ES

SU

RE

(Pa)

INP

UT (w

atts)

700

500

300

600

400

200

100

0

2.5 m/s Face Velocity (456)& Nominal

4V

5.3V

6.3V

7.3V

8.3V

9.3V

10V

4V

5.3V

6.3V

7.3V

8.3V

9.3V

10V

0.31A

0.36A

0.46A

0.61A

0.64A

0.90A

0.89A

1.31A

1.21A

1.64A

1.98A

INP

UT (w

atts)

AIR VOLUME (l/s)

AV

AIL

AB

LE E

XTE

RN

AL

PR

ES

SU

RE

(Pa)

0

100

200

300

400

500

2.5 m/s Face Velocity (595)& Nominal

0.33A

0.42A

0.50A

0.76A

0.70A

1.14A

0.97A

1.33A

1.80A

2.14A

100 200 300 400 500 600

700

600

500

400

300

200

100

0

4V

5.3V

6.3V

7.3V

8.3V

9.3V

10V

4V

5.3V

6.3V

7.3V

8.3V

9.3V

10V

Test Conditions BS 848 PT2 1985. Intallation Type A (free inlet and outlet)

Direct method of measurement (reverberant room)Measured in decibels re 1 picowatt, at maximum airflow

Test Conditions BS 848 PT2 1985. Intallation Type A (free inlet and outlet)

Direct method of measurement (reverberant room)Measured in decibels re 1 picowatt, at maximum airflow

Page 5: EC Motor Fan Coil Units of temperzone IMD Series fan coil units. All temperzone IMD fan coil units are right handed, i.e. when facing the discharge side of the unit, the water and

8 9

IMD 170Y

Cooling Capacity kWEntering Air Temperature 23.0°C db 17.0°C wb Nominal Air Flow 750 l/s

Coil Rows Water Flow l/s

Water Pressure Drop kPa

Entering Water Temperature °C5 6 7 8 9

Total Sensible Total Sensible Total Sensible Total Sensible Total Sensible

40.30 9.3 11.2 9.0 10.3 8.7 9.5 8.4 8.8 8.0 7.8 7.70.45 19.1 13.3 9.9 12.3 9.5 11.3 9.1 10.4 8.7 9.3 8.30.60 33.4 14.8 10.5 13.8 10.1 12.6 9.6 11.5 9.2 10.3 8.7

Heating Capacity Electric Heating Option 6 kWEntering Air Temperature 21.0°C db Nominal Air Flow 750 l/s

Coil Rows Water Flow l/s

Water Pressure Drop kPa

Entering Water Temperature °C

40 45 50 55 60 65 70 75 80

10.09 9.3 4.2 5.4 6.5 7.6 8.7 9.8 10.9 12.1 13.20.14 22.2 5.1 6.4 7.7 9.0 10.3 11.6 13.0 14.3 15.60.18 31.4 5.4 6.9 8.3 9.7 11.2 12.6 14.0 15.5 16.9

IMD 210Y

Cooling Capacity kWEntering Air Temperature 23.0°C db 17.0°C wb Nominal Air Flow 900 l/s

Coil Rows Water Flow l/s

Water Pressure Drop kPa

Entering Water Temperature °C5 6 7 8 9

Total Sensible Total Sensible Total Sensible Total Sensible Total Sensible

40.40 9.5 13.9 11.0 12.8 10.6 11.8 10.1 10.7 9.7 9.8 9.30.60 19.6 16.4 12.0 15.2 11.5 13.9 11.0 12.7 10.5 11.4 10.00.80 33.5 18.2 12.8 16.8 12.2 15.4 11.6 14.0 11.0 12.5 10.4

Heating Capacity Electric Heating Option 9 kWEntering Air Temperature 21.0°C db Nominal Air Flow 900 l/s

Coil Rows Water Flow l/s

Water Pressure Drop kPa

Entering Water Temperature °C

40 45 50 55 60 65 70 75 80

10.08 8.4 4.4 5.6 6.8 7.9 9.1 10.3 11.4 12.6 13.80.12 17.3 5.3 6.8 8.2 9.6 11.1 12.4 13.8 15.2 16.60.16 28.8 6.0 7.5 9.1 10.7 12.2 13.8 15.4 16.9 18.5

Supply Air Outlet

Fan SpeedVolts

Sound Power

SWL dB(A)

Octave Band Frequency Hz125 250 500 1K 2K 4K

Sound Power Levels (SWL) dB

8.3 68 62 64 66 62 59 589.3 75 68 71 71 71 67 6610 77 70 74 73 74 69 68

Supply Air Outlet

Fan SpeedVolts

Sound Power

SWL dB(A)

Octave Band Frequency Hz125 250 500 1K 2K 4K

Sound Power Levels (SWL) dB

7.3 63 60 60 62 58 55 518.7 71 67 68 67 67 63 619.3 75 70 71 70 72 67 65

Air Handling Air Handling

Dimensions

Sound Levels Sound Levels

ELECTRICALACCESS PANEL

910

1095OVERALL

85

360 OA

975HANGING CENTRES

225 285

60

15

DRAIN 19 OD

120

15

630 OA

MOUNTINGSLOTS 20 x 9

530HANGINGCENTRES

600OPTIONAL

SPRING MTGCENTRES

ELECTRICALCONDUIT HOLES

60ACCESSPANEL

1015SPRING MTG CTRS

400340

WATERCONNECTIONS:25 BSP MALE(HEATING 15 BSP MALE)

60

OPTIONALFILTER BOX WITHFILTER ACCESSEACH SIDE

135

FAN ACCESS VIAREMOVEABLE BASE

& DRAIN TRAY,OR VIA TOP PANEL

ELECTRICALACCESS PANEL

1060

1235OVERALL

85

360 OA

1110HANGING CENTRES

225 285

60

15

DRAIN 19 OD

120

15

630 OA

MOUNTINGSLOTS 20 x 9

530HANGINGCENTRES

600OPTIONAL

SPRING MTGCENTRES

ELECTRICALCONDUIT HOLES

60ACCESSPANEL

1155SPRING MTG CTRS

860170

WATERCONNECTIONS:25 BSP MALE(HEATING 15 BSP MALE)

FAN ACCESS VIAREMOVEABLE BASE

& DRAIN TRAY,OR VIA TOP PANEL

60

OPTIONALFILTER BOX WITHFILTER ACCESSEACH SIDE

135

INP

UT (w

atts)

AIR VOLUME (l/s)

AV

AIL

AB

LE E

XTE

RN

AL

PR

ES

SU

RE

(Pa)

0

100

200

300

400

500

2.5 m/s Face Velocity (714)

0.51A

0.44A

0.33A

0.78A

0.71A

1.20A

0.99A

1.78A

1.35A

2.55

2.77A

2.28A

0 200 400 600 800 1000

Nominal

700

600

500

400

300

200

100

0

4V

5.3V

6.3V

7.3V

8.3V

9.3V

10V

4V

5.3V

6.3V

7.3V

8.3V

9.3V10V

INP

UT (w

atts)

AIR VOLUME (l/s)

AV

AIL

AB

LE E

XTE

RN

AL

PR

ES

SU

RE

(Pa)

0

100

200

300

400

500

1.01A

0.79A

1.41A 1.89A

1.50A

1.90A

2.36A

2.94A

2.5 m/s Face Velocity (833)

Nominal

0 200 400 600 800 1000

700

600

500

400

300

200

100

0

6V

6.7V

7.3V

8V

8.7V

9.3V

6V

6.7V

7.3V

8V

8.7V

9.3V

Test Conditions BS 848 PT2 1985. Intallation Type A (free inlet and outlet)

Direct method of measurement (reverberant room)Measured in decibels re 1 picowatt, at maximum airflow

Test Conditions BS 848 PT2 1985. Intallation Type A (free inlet and outlet)

Direct method of measurement (reverberant room)Measured in decibels re 1 picowatt, at maximum airflow

Dimensions

Note: Airflows are for dry coil. Reduce airflow by 10% in high moisture removal conditions.

Airflows given are for IMD-Y units without filter installed.

Refer back page for filter pressure drop.

Note: Airflows are for dry coil. Reduce airflow by 10% in high moisture removal conditions.

Airflows given are for IMD-Y units without filter installed.

Refer back page for filter pressure drop.

Page 6: EC Motor Fan Coil Units of temperzone IMD Series fan coil units. All temperzone IMD fan coil units are right handed, i.e. when facing the discharge side of the unit, the water and

10 11

Supply Air Outlet

Fan SpeedVolts

Sound Power

SWL dB(A)

Octave Band Frequency Hz125 250 500 1K 2K 4K

Sound Power Levels (SWL) dB

7.3 66 65 63 63 62 59 558.3 71 70 68 68 66 64 619.3 78 76 75 75 73 71 69

Supply Air Outlet

Fan SpeedVolts

Sound Power

SWL dB(A)

Octave Band Frequency Hz125 250 500 1K 2K 4K

Sound Power Levels (SWL) dB

7.3 65 61 63 63 60 56 538.3 70 66 68 67 66 62 599.3 77 71 74 72 73 69 66

IMD 420Y

Cooling Capacity kWEntering Air Temperature 23.0°C db 17.0°C wb Nominal Air Flow 1800 l/s

Coil Rows Water Flow l/s

Water Pressure Drop kPa

Entering Water Temperature °C5 6 7 8 9

Total Sensible Total Sensible Total Sensible Total Sensible Total Sensible

41.50 8.5 33.4 24.4 30.9 23.3 28.3 22.3 25.7 21.2 23.2 20.22.50 20.7 38.8 26.7 35.9 25.5 33.0 24.2 30.1 23.0 27.2 21.83.00 29.8 40.6 27.5 37.4 26.1 34.5 24.8 31.2 23.4 28.3 22.2

Heating Capacity Electric Heating Option 12 kWEntering Air Temperature 21.0°C db Nominal Air Flow 1800 l/s

Coil Rows Water Flow l/s

Water Pressure Drop kPa

Entering Water Temperature °C

40 45 50 55 60 65 70 75 80

10.30 3.9 11.2 14.1 17.0 20.0 23.0 25.9 28.8 31.8 34.70.60 13.2 13.6 17.2 20.8 24.3 27.9 31.4 35.0 38.5 42.10.90 27.4 15.0 18.9 22.8 26.8 30.7 34.6 38.5 42.5 46.4

Air Handling

Dimensions

Sound Levels

ELECTRICALACCESS PANEL

1375

1620 OA

125

1518MOUNTING CENTRES

300425

80

DRAIN 28 OD

240

975

694OPTIONAL

SPRING MTGCENTRES

325

ELECTRICALCONDUIT HOLES

6565

575 OA

730 OA

ACCESSPANEL

600MOUNTING

STRAPCENTRES

WATER CONNECTIONS:32 BSP MALE(HEATING 32 BSP MALE)

FAN ACCESS VIAREMOVEABLE BASE

& DRAIN TRAY,OR VIA TOP PANEL

OPTIONALFILTER BOX WITHFILTER ACCESSEACH SIDE

150

35

75

IMD 280Y

Cooling Capacity kWEntering Air Temperature 23.0°C db 17.0°C wb Nominal Air Flow 1250 l/s

Coil Rows Water Flow l/s

Water Pressure Drop kPa

Entering Water Temperature °C5 6 7 8 9

Total Sensible Total Sensible Total Sensible Total Sensible Total Sensible

40.60 7.0 19.2 15.2 17.7 14.6 16.4 14.0 14.8 13.4 13.4 12.91.00 17.8 23.4 16.9 21.8 16.2 19.9 15.5 18.1 14.7 16.4 14.11.40 33.1 26.2 18.2 24.2 17.3 22.1 16.4 20.0 15.5 18.1 14.7

Heating Capacity Electric Heating Option 9 kWEntering Air Temperature 21.0°C db Nominal Air Flow 1250 l/s

Coil Rows Water Flow l/s

Water Pressure Drop kPa

Entering Water Temperature °C

40 45 50 55 60 65 70 75 80

10.20 2.8 7.4 9.4 11.3 13.2 15.2 17.1 19.1 21.0 23.00.50 14.5 9.5 12.0 14.4 17.0 19.5 21.9 24.4 26.9 29.40.80 33.2 10.5 13.3 16.0 18.8 21.6 24.3 27.1 29.8 32.6

Air Handling

Dimensions

Sound Levels

ELECTRICALACCESS PANEL

1180

1360OVERALL

80

425 OA

1240HANGING CENTRES

230350

55

15

DRAIN 19 OD

15

630 OA

MOUNTINGSLOTS 20 x 9

530HANGINGCENTRES

600OPTIONAL

SPRING MTGCENTRES

ELECTRICALCONDUIT HOLES

60ACCESSPANEL

1285SPRING MTG CTRS

860165

175

WATERCONNECTIONS:32 BSP MALE(HEATING 25 BSP MALE)

FAN ACCESS VIAREMOVEABLE BASE

& DRAIN TRAY,OR VIA TOP PANEL

60

OPTIONALFILTER BOX WITHFILTER ACCESSEACH SIDE

135

INP

UT (w

atts)

AIR VOLUME (l/s)

AV

AIL

AB

LE E

XTE

RN

AL

PR

ES

SU

RE

(Pa)

0

100

200

300

400

500

1600

1400

1200

1000

800

600

400

200

0

0 300 600 900 1200 1500

0.86A

0.61A

0.81A 1.45A 2.18A 3.22A

1.14A

1.55A

2.42A

3.90A

3.31A

2.5 m/s Face Velocity (1115)

Nominal

4V

4V

5.3V

6.3V

7.3V

8.3V

9.3V

10V

5.3V

6.3V

7.3V

8.3V

9.3V

10V

INP

UT (w

atts)

AIR VOLUME (l/s)

AV

AIL

AB

LE E

XTE

RN

AL

PR

ES

SU

RE

(Pa)

1.60A

2.40A

3.60A

5.10A

7.10A

2.30A 3.90A 5.90A0

100

200

300

400

500

2400

2100

1800

1500

1200

900

600

300

0

400 800 1200 1600 2000 2400

2.5 m/s Face Velocity (1740)

Nominal

5.3V

6.3V

7.3V

8.3V

9.3V

5.3V

6.3V

7.3V

8.3V

9.3V

Test Conditions BS 848 PT2 1985. Intallation Type A (free inlet and outlet)

Direct method of measurement (reverberant room)Measured in decibels re 1 picowatt, at maximum airflow

Test Conditions BS 848 PT2 1985. Intallation Type A (free inlet and outlet)

Direct method of measurement (reverberant room)Measured in decibels re 1 picowatt, at maximum airflow

Note: Airflows are for dry coil. Reduce airflow by 10% in high moisture removal conditions.

Airflows given are for IMD-Y units without filter installed.

Refer back page for filter pressure drop.

Note: Airflows are for dry coil. Reduce airflow by 10% in high moisture removal conditions.

Airflows given are for IMD-Y units without filter installed.

Refer back page for filter pressure drop.

Page 7: EC Motor Fan Coil Units of temperzone IMD Series fan coil units. All temperzone IMD fan coil units are right handed, i.e. when facing the discharge side of the unit, the water and

12 13

WIRING DIAGRAM: IMD 95Y – 280Y

Supply Air Outlet

Fan SpeedVolts

Sound Power

SWL dB(A)

Octave Band Frequency Hz125 250 500 1K 2K 4K

Sound Power Levels (SWL) dB

10 85 80 78 79 79 80 759 81 78 76 77 76 74 728 78 75 73 74 73 71 697 74 72 69 71 69 67 656 70 68 65 67 66 63 615 66 63 60 63 61 58 55

IMD 550Y

Cooling Capacity kWEntering Air Temperature 23.0°C db 17.0°C wb Nominal Air Flow 2350 l/s

Coil Rows Water Flow l/s

Water Pressure Drop kPa

Entering Water Temperature °C5 6 7 8 9

Total Sensible Total Sensible Total Sensible Total Sensible Total Sensible

42.00 9.5 43.9 31.9 40.5 30.5 37.2 29.1 33.8 27.7 30.5 26.43.00 20.6 49.9 34.5 46.1 32.9 42.3 31.2 38.5 29.6 34.6 28.04.00 33.4 53.2 36.0 49.5 34.3 45.2 32.5 41.4 30.8 37.0 29.0

Heating Capacity Electric Heating Option 18 kWEntering Air Temperature 21.0°C db Nominal Air Flow 2350 l/s

Coil Rows Water Flow l/s

Water Pressure Drop kPa

Entering Water Temperature °C

40 45 50 55 60 65 70 75 80

10.40 4.5 14.7 18.6 22.5 26.3 30.1 34.0 37.9 41.7 45.60.80 15.4 17.9 22.5 27.2 31.9 36.6 41.3 46.0 50.7 55.41.20 31.5 19.6 24.8 30.0 35.2 40.2 45.4 50.6 55.8 60.9

Air Handling

Dimensions

Sound Levels

ELECTRICALACCESS PANEL

1430

1675OVERALL

125

1573MOUNTING CENTRES

310

555

80

DRAIN 28 OD

1030

694OPTIONAL

SPRING MTGCENTRES

325

ELECTRICALCONDUIT HOLES

6565

700OVERALL

730 OA

ACCESSPANEL

355

600MOUNTING

STRAPCENTRES

WATER CONNECTIONS:32 BSP MALE(HEATING 32 BSP MALE)

FAN ACCESS VIAREMOVEABLE BASE

& DRAIN TRAY,OR VIA TOP PANEL

OPTIONALFILTER BOX WITHFILTER ACCESSEACH SIDE

150

35

65

INP

UT (w

atts)

AIR VOLUME (l/s)

AV

AIL

AB

LE E

XTE

RN

AL

PR

ES

SU

RE

(Pa)

2.30A

1.50A

2.30A

3.50A

5.00A

6.90A

6.70A

3.70A 5.80A 8.60A0

100

200

300

400

500

3200

2800

2400

2000

1600

1200

800

400

0

800 1200 1600 2000 2400 2800

750RPM

2.5 m/s Face Velocity (2230)

Nominal

5V

6V

7V

8V

9V

10V

5V

6V

7V

8V

9V

10V

Test Conditions BS 848 PT2 1985. Intallation Type A (free inlet and outlet)

Direct method of measurement (reverberant room)Measured in decibels re 1 picowatt, at maximum airflow

Note: Airflows are for dry coil. Reduce airflow by 10% in high moisture removal conditions.

Airflows given are for IMD-Y units without filter installed.

Refer back page for filter pressure drop.

VOLT

AGE

INV

230/

240

3 SP

EEDS

CO

NTRO

LOP

TION

IMD

MOD

EL

95Y

135Y

IFM

170Y

210Y

280Y

1.25

kW

600W

900W

1.25

kW

1.25

kW

L1N

IN0V+V

MLCOM

OUT

0V+V

H

PURP

LEOR

ANGE

GREY

0V

0-10

V

K.L.

E291-0

00-1

62

25-1

1-14

CLIE

NT W

IRIN

G

ALC

ALC

ANAL

OGUE

LOG

IC C

ONTR

OLLE

R.

0-10VDC0V

IFM

Blac

kRe

d

Whi

te

Mot

or D

river

Yello

w

Heat

sink

Yello

wBl

ack Blac

k

HIGH

MEDLOW

ML HCOM

IFM

INDO

OR F

AN M

OTOR

FRB

FAUL

T RE

LAY

BOAR

D

GREE

N/YE

LBL

ACK

BLAC

K

WHI

TEW

HITE

FRB

Ferri

te- C

oil w

ires

3 tu

rns

arou

nd fe

rrite

cor

e. S

epar

ate

thes

e 3

wire

s fro

m o

ther

s.

IFM

MAX

AM

PS

OFF

N/C

COM

N/O

DA

W.A

.S.GR

EY

WHI

TE

RED

BROW

N

ORAN

GE

PURP

LE

20-8-

15EC

MOT

OR/D

RIVE

R CH

ANGE

D, A

.L.C

ADDE

D &

WIR

ING

COLO

URS

CHAN

GED

TO M

ATCH

STD

PRO

DUCT

S

4.9

3.3

6.8

6.8

6.8

BW

.A.S

.25

-9-15

CHAN

GED

EAR

THIN

G A

RRAN

GEM

ENT,

REM

OVE

D T

ERM

. 1 &

2 F

OR

REM

OTE

ON

/OFF

OPTI

ONAL

0-10

V (D

C) S

IGNA

LFR

OM B

MS

OROT

HER

CONT

ROLL

ER

3 SP

EEDS

CO

NTRO

LOP

TION

AL

0-10

VCO

NTRO

LOP

TION

AL

REM

OTE

ON/O

FF

REM

OTE

ON/O

FF

CN4

013

A.K.

B08

-01-18

ECC 1

260 R

ENAM

ED M

OTOR

DRI

VER.

OR R

ED AD

DED

TO FI

LTER

WIR

E COL

OURS

. ALC

DIP

SWIT

CH SE

TTIN

GS U

PDAT

ED

and I

sola

tor

Sw

itch

Clie

nt

Ext

ernal

Pro

tect

ion

OR

RED

OR

RED

ONOF

F

FACT

ORY

SETT

ING

OFF

ON1 2 3 4 5 6 7 8

LEAV

E OF

FDO

NOT

USE

High

Spe

ed R

ange

Low

Spe

ed R

ange

MAX

Vdc

Vspa

n

00

00

00

10

10

01

10

11

01

01

11

6.7

7.3 8 8.3

8.7 9 9.3

2 3 4.5 6

23

45

ALC

DIP

Switc

h Se

tting

s

Spee

d Se

tting

No E

lect

ric H

eat

Elec

tric

Heat

Spee

d Ra

nge

8V M

ax. S

peed

2V S

peed

Ran

ge

(40s

Fan

run

on)

(120

s Fa

n ru

n on

)

Spee

d Se

tting

and

Ran

ge D

IP S

witc

h Op

tions

.Sp

eed

Setti

ngSp

eed

Rang

e

NOTE

: Do

NOT

conn

ect B

OTH

3 sp

eed

L/M

/H s

witc

h an

d al

so 0

-10V

(DC)

sig

nal.

Only

ONE

con

trol m

etho

d m

ay b

e co

nnec

ted

at a

tim

e.If

in d

oubt

ask

!

NOTE

: Unl

ess

off,

min

imum

act

ive

volta

ge o

utlim

ited

to 2

.2V

DC w

hen

DIP

Sw. 7

off,

and

to 1

.2V

DC w

hen

DIP

Sw. 7

on.

77

OFF

ON 3 3.4

3.8

4.2

4.55

4.95

5.35

OFF

ON 2.75 4.52 3.5

0 1 0 1 0 1 01 1

(Low

= 6

V)

Spee

d Se

tting

(DIP

Sw

. 1 to

3) s

ets

the

max

. spe

ed/v

olta

ge (H

IGH)

.Sp

eed

Rang

e (D

IP S

w. 4

& 5

) set

s th

e di

ffere

nce

betw

een

the

max

. spe

ed a

nd th

e m

in. s

peed

/vol

tage

(LOW

).W

ith th

e 3

spee

d co

ntro

l the

med

ium

spe

ed is

alw

ays

halfw

ay b

etw

een

HIGH

and

LOW

.

11

105.

75

D

D

DN4

059

A.K.

B15

-05-18

SPEE

D SE

TTIN

G 4.5

5V C

ORRE

CTED

TO

8V A

ND S

PEED

RAN

GE 2

.55V

CORR

ECTE

D TO

6 V

Page 8: EC Motor Fan Coil Units of temperzone IMD Series fan coil units. All temperzone IMD fan coil units are right handed, i.e. when facing the discharge side of the unit, the water and

14 15

WIRING DIAGRAM: IMD 420Y & 550Y

Suggested SpecificationFurnish and install temperzone fan coil units as indicated on the schedule.

Base Unit The base unit shall be fabricated of galvanised steel and insulated with closed cell foam. The unit shall be complete with water coil, one or more centrifugal fans, condensate drain tray, enclosed electrical box, supply air duct spigot and return air duct spigot. Units shall have mounting holes on the top side for ease of installation. Spring mounts (optional) shall be available for mounting the unit.

Motor Motors shall be electronically commutated (EC) type with the option of stepped speed control or 0-100% variable capacity using a 0-10V dc signal supplied by BMS or sophisticated controller.*

Coils Coils shall be comprised of die formed plate type aluminium fins mechanically bonded to high efficiency seamless inner rifled copper tubing. Water connections shall be BSP male threaded. Cooling coils shall have a manual air vent.

Drain Tray Drain tray shall have an adjustment for inducing a positive drainage with the unit level. The tray shall project under the entire length and width of the coil including headers and return bends.

Filters Filters shall be removable, 13 mm thick, washable, rated EU2, and mounted in a plastic frame.

Insultation The base unit shall be insulated with closed cell foam to ensure no particles are introduced into the air stream. Insulation shall be foil faced and meet fire test standards AS 1530.3 (1989) and BS 476 parts 6 & 7.

Electric Heat Electric elements shall be fin-tube constructed of stainless steel and include both a manual and auto reset high temperature cutout switches as well as two contactors (as required by AS/NZS 3350.2.40 1997). Additional safety protection shall be provided by an air pressure switch and circuit breaker control. A fan run-on timer shall be provided for heat dissipation.

INITIAL (Clean Filter)

FINAL PRESSURE

DROP125 Pa

0 0.5 1.0 1.5 2.0 2.5 3.0 3.5

70

60

50

40

30

20

10

0

FILTER FACE VELOCITY (m/s)

PRES

SURE

DRO

P (P

a)

EU2 (G2)

Filter Pressure Drop

Filter Area :IMD 95Y 0.163 m2 2.8 m/sIMD 135Y 0.211 m2 2.9 m/sIMD 170Y 0.259 m2 2.9 m/sIMD 210Y 0.293 m2 3.1 m/sIMD 280Y 0.408 m2 3.1 m/sIMD 420Y 0.569 m2 3.2 m/sIMD 550Y 0.771 m2 3.1 m/s

Note:G2 / EU2 filters do not meet Australian standards so are not to be used in the Australian market. G4 / EU4 filters, that meet the Australian standard, are best located behind return air grilles or in the ducting to reduce the velocity and therefore resistance losses.

G2 / EU2 rated filter media (standard)

* The fan/motor may also be set to a single predetermined speed using a potentiometer.

VOLT

AGE

INV

420Y

, 55

0Y

230/

240

MOD

ELIM

D

9A/M

TREC

C M

OTOR

DRI

VER

AMPS

(MAX

)

CUP

DATE

D TO

NEW

EC D

RIVE

R12-

02-15

K.L.E.

G

and I

sola

tor

Sw

itch

L1 N E

IN0V+V

MLCOM

OUT

0V+V

H

PURP

LE

ORAN

GE

GREY

0V

0-10

V

K.L.

E291-0

00-1

03

12-0

2-15

CLIE

NT W

IRIN

G

OPTI

ONAL

0-10

V (D

C) S

IGNA

LFR

OM B

MS

OROT

HER

CONT

ROLL

ER

ALC

ALC

ANAL

OGUE

LEV

EL C

ONTR

OLLE

R.

0-10VDC0V

IFM

2

Blac

kRe

d

Whi

te

Yello

w

Heat

sink

Yello

wBl

ack

or B

row

nBl

ack

or B

row

n

HIGH

MED

LOW

ML H

COM

IFM

INDO

OR F

AN M

OTOR

FRB

FAUL

T RE

LAY

BOAR

D

GREEN

/YEL

WHI

TEW

HITE

BLAC

KBL

ACK

FRB

Ferri

te- C

oil w

ires

3 tu

rns

arou

ndfe

rrite

cor

e.Se

para

te th

ese

3w

ires

from

oth

ers.

IFM

1

Blac

kRe

d

Whi

te

Yello

w

Heat

sink

Yello

wBl

ack

or B

row

nBl

ack

or B

row

n

GREEN

/YEL

WHI

TEW

HITE

BLAC

KBL

ACK

FRB

Ferri

te- C

oil w

ires

3 tu

rns

arou

ndfe

rrite

cor

e.Se

para

te th

ese

3w

ires

from

oth

ers.

3 SP

EEDS

CO

NTRO

LOP

TION

DRY

CONT

ACTS

N/C

COM

N/O

DRY

CONT

ACTS

N/C

COM

N/O

GREY

WHI

TE

RED

BROW

N

ORAN

GE

PURP

LE

DCH

ANGE

D W

IRIN

G CO

LOUR

S TO

MAT

CH S

TAND

ARD

PROD

UCTS

20-8-

15W.

A.S

ECH

ANGE

D EA

RTHI

NG A

RRAN

GEME

NT, R

EMOV

ED T

ERM.

FOR

REM

OTE

ON/O

FF20

-8-15

W.A.S

3 SP

EEDS

CO

NTRO

LOP

TION

AL

0-10

VCO

NTRO

LOP

TION

AL

REM

OTE

ON/O

FF

REM

OTE

ON/O

FF

E

WU VSR-

SR+

FR-

MO

FR+

0V+12

V0-

10V

ACL

E

PE ACN

PE

Mot

or D

river

E

WU VSR-

SR+

FR-

MO

FR+

0V+12

V0-

10V

ACL

E

PE ACN

PE

Mot

or D

river

ECC 12

60 RE

NAME

D MOT

OR DR

IVER.

OR RE

D ADD

ED TO

FILTE

R WIRE

COLO

URS.

ALC DI

P SWI

TCH S

ETTING

S UPD

ATED

10-01

-18A.K

.BN4

013

F

Gree

n/Ye

llow

21

Clie

nt

Ext

ern

al Pro

tect

ion

OR R

EDOR

RED

OR R

EDOR

RED

ONOF

F

FACT

ORY

SETT

ING

OFF

ON1 2 3 4 5 6 7 8

LEAV

E OF

FDO

NOT

USE

High

Spe

ed R

ange

Low

Spe

ed R

ange

MAX

Vdc

Vspa

n

00

00

00

10

10

01

10

11

01

01

11

6.7

7.3 8 8.3

8.7 9 9.3

2 3 4.5 6

23

45

ALC

DIP

Switc

h Se

tting

s

Spee

d Se

tting

No E

lect

ric H

eat

Elec

tric

Heat

Spee

d Ra

nge

8V M

ax. S

peed

2V S

peed

Ran

ge

(40s

Fan

run

on)

(120

s Fa

n ru

n on

)

Spee

d Se

tting

and

Ran

ge D

IP S

witc

h Op

tions

.Sp

eed

Setti

ngSp

eed

Rang

e

NOTE

: Do

NOT

conn

ect B

OTH

3 sp

eed

L/M

/H s

witc

h an

d al

so 0

-10V

(DC)

sig

nal.

Only

ONE

con

trol m

etho

d m

ay b

e co

nnec

ted

at a

tim

e.If

in d

oubt

ask

!

NOTE

: Unl

ess

off,

min

imum

act

ive

volta

ge o

utlim

ited

to 2

.2V

DC w

hen

DIP

Sw. 7

off,

and

to 1

.2V

DC w

hen

DIP

Sw. 7

on.

77

OFF

ON 3 3.4

3.8

4.2

4.55

4.95

5.35

OFF

ON 2.75 4.52 3.5

0 1 0 1 0 1 01 1

(Low

= 6

V)

Spee

d Se

tting

(DIP

Sw

. 1 to

3) s

ets

the

max

. spe

ed/v

olta

ge (H

IGH)

.Sp

eed

Rang

e (D

IP S

w. 4

& 5

) set

s th

e di

ffere

nce

betw

een

the

max

. spe

ed a

nd th

e m

in. s

peed

/vol

tage

(LOW

).W

ith th

e 3

spee

d co

ntro

l the

med

ium

spe

ed is

alw

ays

halfw

ay b

etw

een

HIGH

and

LOW

.

Gree

n/Ye

llow

G

11

105.

75

SPEE

D SET

TING 4

.55V C

ORRE

CTED

TO 8V

AND S

PEED

RANG

E 2.55

V COR

RECT

ED TO

6V15

-05-18

A.K.B

N405

9G

G

Page 9: EC Motor Fan Coil Units of temperzone IMD Series fan coil units. All temperzone IMD fan coil units are right handed, i.e. when facing the discharge side of the unit, the water and

05/18 Pamphlet No. 3982 © temperzone limited 2018

Available frommanufactured and distributed by:temperzone limitedHead Office, Auckland : 38 Tidal Rd, Mangere, N.Z.Private Bag 93303, Otahuhu, NEW ZEALAND. Email [email protected] Website: www.temperzone.co.nz

temperzone australia pty ltdHead Office, Sydney : 14 Carnegie Pl.PO Box 6448, Delivery Centre, Blacktown, NSW 2148, AUSTRALIA. Email [email protected] Website: www.temperzone.com.au

Note: The manufacturer reserves the right to change specifications at any

time without notice or obligation.