ecopro anmo intelligent anti-epidemic monitoring
TRANSCRIPT
Operating Instruction Manual
ECOPRO ANMO Intelligent
Anti-Epidemic Monitoring Workstation
Operating Instruction Manual
Thank you for purchasing our products, please read this manual carefully
before the operation.
1
Operating Instruction Manual
2
ECOPRO ANMO Intelligent Anti-Epidemic Monitoring Workstation
Operating Instruction Manual
I. Introduction
ECOPRO ANMO Intelligent Anti-Epidemic Monitoring Workstation is suitable for public
health epidemic monitoring, automatic body temperature detection, mask wearing
detection, and spray disinfection. This workstation will reduce the labor intensity of
personnel, improve the safety for the personnel under high-frequency contacts, and
effectively avoid the risk of cross infection in public areas and crowded places.
ANMO is equipped with accessories such as casters and ramps, which is suitable for
various application scenarios. It has strong mobility and simple deployment, can work
sustainably when plugged in.
ANMO provides one-stop solutions including body temperature measurement,
disinfection, status recognition, commuting punch-in and data upload.
II. Scope of application
ECOPRO ANMO Intelligent Anti-Epidemic Monitoring Workstation can be used for
government agencies, hospitals, schools, supermarkets, communities, office buildings,
railway stations, airports, factories and other public areas and crowded places.
Operating Instruction Manual
III. Product Dimension
IV. Product Features
1400Product Dimension Diagram
Product Main Functions Diagram
Disinfection AreaDetection Area
Operating Instruction Manual
can collect body temperatures in real time, extract and compare peak value, and output
signal lamps and voice prompt. The temperature measurement module can adjust the
angle to adapt to different people.
When the body temperature is normal, the voice broadcasts the body temperature
value.
When the body temperature exceeds 37.3 ℃, it will give a double prompt of sound and
image, and automatically take photos and upload them to the administrator's computer
or mobile phone.
2. Automatic Mask Wearing Detection
ANMO can detect those who do not wear a mask, and voice reminds "Please wear a
mask".
3. Auto-induction Spray Hand Disinfection
ANMO adopts non-contact induction spraying, and can carry out hand disinfection
simultaneously when measuring temperature, with high efficiency, safety and health.
4. Commuting punch-in and wireless data transmission
ANMO can also achieve commuting punch-in and data unloading at the same time.
The face recognition system can support offline storage of 100,000 face photos and
recognition records. It can also monitor abnormal people and upload them to the server.
1. Automatic temperature monitoring
ANMO adopts imported high-precision industrial infrared spectrum sensor, which is
calibrated by blackbody radiation source before delivery. It can realize non-contact, fast
and reliable body temperature measurement, and effectively avoid cross infection. It
Operating Instruction Manual
5
Alarm light for
abnormaltemperature and
without mask Light for normal
temperature
Infraredtemperature
camera Face recognition
camera
Display screen
Flash light
Person punch
5. Auto-induction 3D spray disinfection
ANMO is equipped with microwave moving object induction sensor. When the
personnel enters, the automization machine is quickly started to perform
spray disinfection in the disinfection area.
6. Wind curtain closed disinfection area
Half of the space of ANMO is disinfection area. The floor of this area is completely
covered with disinfection carpet. The atomizing disinfection machine sprays disinfection
gas into this area and a wind curtain system is set to keep the area full of disinfection
gas at all times, for disinfecting the human body in all directions.
7. Non-contact during the whole process
During the whole process: temperature measurement → punch-in → mask recognition
→ hand disinfection → whole body disinfection, there is zero contact with the equipment,
effectively preventing cross infection.
Operating Instruction Manual
6
ANMO has two sets of universal casters with brakes and two sets of directional casters
with brakes, which are convenient for moving, fast layout, and can reduce storage
space occupation. Also nylon wheels to adapt to various road conditions.
9. Foldable auxiliary channel
The entrance and exit of ANMO are equipped with auxiliary access ramps, which are
convenient for people and wheelchairs to enter. The ramps are foldable and convenient
for movement and storage.
10. Simple deployment
The equipment uses 220V AC power, and the power consumption is less than 500W.
The layout is simple, no special personnel is required to install and debug the
equipment. The operation is simple, easy to learn and operate.
11. Electricity safety
ANMO is equipped with leakage protection system and anti-lightning surge system to
ensure the safety of users.
12. Passage lighting
The passage in ANMO is equipped with auto-sensing LED lighting, which is convenient
for use at night or in dark light environment.
8. Strong mobility
Operating Instruction Manual
7
➢ Monitoring platformMonitoring platform is an integrated
management platform for the deployment of
body temperature monitoring in the premisesof
daily monitoring, system management and
emergency command. It is a network platform
of Internet architecture, which has many
functions such as alarm processing, recording,
query, statistics and detection data curve
output of personnel traffic and data at
monitoring points in various regions.
➢ Transmission NetworkThe human temperature data and high-risk
data collected by the terminal device are sent
to the server over a 4G network.
Data acquisition system
It is mainly responsible for on-site image
acquisition, body temperature data acquisition
and network transmission. It is an integrated
machine of face recognition and body
temperature detection, which is used to monitor
body temperature data and collect face
recognition data. Alarm is provided for testdatawith a body temperature exceeding 37.3℃.
4G Wireless Transmission Network
Face recognition and body temperature detection integrated machine
Terminal Device
Monitoring PCServerCommand Screen
Monitoring Data Analysis Center
Public Publishing PlatformGovernment Monitoring Platform
V. Performance Parameters
1、Monitoring Module
1)Temperature alarm module
① Scheme system topology
② Face recognition and body temperature detection integrated machine –
Product Functions
⚫ Support the face recognition of people wearing masks
while completing temperature detection;
⚫ Built-in low-power temperature detection module,
second-level completion of detection, detection
distance in 0.5m;
⚫ Support verification of 1:N. Live detection in 1:N mode
to prevent photo and video attacks;
⚫ The dynamic face detection and tracking recognition
algorithm based on video flow
⚫ Support offline storage of 100,000 face photos and
recognition records;
⚫ Support preservation of face recognition on-site
photos;
⚫ Customizable development for functions of visitor
self-service appointment in WeChat official account and users face registration;
⚫ Support interface docking, support customization;⚫ Wireless remote data transmission, real-time display of data, information transparency a
accessible.⚫ Flexible storage of data, analysis of historical curve at any time, monitoring and management of
big data is accessible.
Operating Instruction Manual
8
③ Face recognition and body temperature detection integrated machine
- Parameters and Specifications
Parameters and Specifications
Hardware
Display Screen 7-inch LCD, resolution:1024 x 600@60HZ
Appearance material Aluminium housing, organic glass panel
Performance
Camera recognition height 1.2-2.2 m
Camera recognition distance 0.5-3m
Body temperature detection
distance
0.3-0.5m
Recognition technologySupport face recognition for swearing mask and infrared
array thermal imaging temperature detection
Face angles 30 degrees left and right, 30 degrees up and down
Near-infrared live detection, embedded visible face
Recognition technology recognition, adapted to most indoor and outdoor
environment, can be quickly identified in mobile
Detection tracking in 15ms, comparison per thousand
people in 80ms , feature extraction in 300ms
Name announcement display, customized information
broadcast display
Recognition time
Status display
Face Library 10,000 (expandable)
Master board interface
Power interfaceOne external socket and one built-in 6P socket (With STB)
DC 12V input
Network interface One RJ45 10M / 100M Adaptive Ethernet Port
Extending the interface One way of UART, One way of RS485
One way of WIFI, support 2.4G/5G WiFi and Wi-Fi
802.11b/g/n protocol
Expandable for one way of 3G (WCDMA, EVDO, CDMA),WIFI
3G/4G (Optional) GSM) or
(LTE-TDD/LTE-FDD/TD-SCDMA/EDGE/GPRS/GSM)
4G
SD Card Interface Scale up to 64GBTF card
Five ports, USB HOST (two external ports and three
built-in ports, one of the external ports is OTG)USB 2.0 interface
Camera parameters
CameraTwo megapixels, flat angle wide dynamic camera,
automatic white balance, automatic backlight optimization
1920*1080
1/3 inch image sensor, 4mm/6mm focal length, F2.4
aperture
Effective pixels
Lens
Operating Instruction Manual
9
Minimum illumination Colors 0.05Lux @F1.2 (ICR)
Signal-to-noise ratio ≥39db(AGC OFF)
Human temperature
measurement parameters
Use of German imported infrared thermal imaging
module
Thermal resolution
Thermal Imaging
Perspective(FOV)
Temperature measurement
range
Temperature measurement
distance
Temperature measurement
accuracy
32 x 32 Array
30°* 30°
30℃-45℃
0.5m
±0.3℃
Card reading module
(Optional)
Card type identification Read M1IC Card Series Number and ID Series Number
RF operation frequency 13.56MHZ
Operation effective distance <3cm
Reading rate 15 times per second
ID module (Optional)
Standard specification
Conforms to ISO/IEC 14443 Type standard B, as well as
“GA450-2013 Desktop Resident ID Reader General
Technical Requirements”, “GA467 Resident ID Verification
Security Control Module Interface Technical
Specifications” and “GA/T1011-2012 Resident ID
Fingerprint Collector General Technical Requirements”
<1s
Card reading time
Reading distance 0-30mm
Data interface USB
Power specifications USB-powered
Operation frequency 13.56MHZ±7KHZ(fc)
General parameters
Operation temperature -10℃ - +50℃
Operation humidity 10~90% relative humidity
Power supply DC12V/3A
Device power consumption ≦25W
Size of device 218 x 116 x 22mm (Length*Width*Height)
Weight of device 0.3 kg (varies by configuration)
Operating Instruction Manual
10
Name Temperature Measurement Time
Abnormal data list
The first body temperature is detected to be high, the second
temperature detection is still high, so this person is transferred
to the hospital for further diagnosis.
Further Diagnosis
④ Examples of platform presentationAlarm display of abnormal person temperature data and time:
Processing and record of abnormal data:
View of Total Personnel Flow Statistics, Historical Data Curves, Abnormal
Personnel Statistics
2、Hand Disinfection Module
Power: Four No. 5 batteries
Power: ≤20W
Operating Instruction Manual
11
Fluid Spray Volume: 1ml±10%
3. Spray Disinfection Module
Voltage: 220V
Power: 200W
Volume: 24L
Atomization capacity: 3kg / h
Continuous use time for one filling: 8h
4. Air curtain module
Voltage: 220V
Power: 110W
Wind speed: 7m / S
Noise: 57db (a)
5. Lighting module
Voltage: 220V
Power: 9W
Color temperature: 5700k
Luminous flux: 650lm
Light source: LED
Quantity: 2Power
Operating Instruction Manual
12
Switch of
Nebulizer
Automatic
nebulizingLightMonitoring
moduleMain
Switch
VI. Commissioning Instruction
Commissioning Procedure:
1. Push up main switch;
2. Connect 220V power;
3. Turn on the relevant switches center closet. Functions of switches are shown in the
following figure.
Turn on the relevant switch according to usage requirement.
① Pull down the switch of nebulizer while not using it;
② Push up the switch of automatic nebulizer to start automatic nebulizing.
(Continuous nebulizing while pulled down);
4. Push up the monitoring module switch and wait for the monitoring module tostart;
5. Push up the switch of nebulizer. After the nebulizer has operated for 3 minutes, the
procedures of temperature detection, disinfection and work attendance check can be
started.
6. The nebulizer can be adjusted to work continuously, or work when the device detects
a living body (automatic nebulizing), see point 2.
Operating Instruction Manual
13
①
②
Disinfection AreaTemperature detection area
VII. Usage Instruction
1. Equipment Using Process:
User enters the intelligent anti-epidemic monitoring workstation and reach the
temperature detection area ①, and stands at this position for frontal temperature
measurement and face recognition punch-in. Meanwhile, the workstation will monitor if
the user has worn a mask and then disinfect his hands. Then user can enter the
disinfection area ②, and wait for a body disinfection for at least 2 seconds in the
disinfection area, and then leave the workstation and enter the relevant areas to study
or work.
2. Usage Instruction of Monitoring Module
After startup, the monitoring module automatically enters the face recognition &
temperature detection mode. User shall stand still at about 0.5m in front of the
recognition module. The detection module will detect body temperature and recognize
mask wearing, and give corresponding voice and text prompt.
① Pass: Normal body temperature and wearing a mask
Operating Instruction Manual
14
② Please wear a mask: User is not wearing a mask;
③ Abnormal body temperature: User’s body temperature has exceeded normal
standard.
Backstage management instruction:
① After purchasing this product, customer account and password will be provided to
log in the big data service platform;
② Use the offered account and password to log in the platform, the web site is
http://139.159.244.16:7070/index.koala?theme=default#
After logging in, click the vehicle monitoring→access record, as shown below:
③Introduce the equipment code and the simultaneous travelling time to check and
derive the information as shown below:
3. Hands disinfection module instruction
Put both your hands under the hand sterilizer to sense the liquid. After filling the
disinfectant, the hand sterilizer needs to repeat the induction action several times so as
to exhaust the air in the pump, and then it can be used normally.
4. Spray disinfection module instruction:
Operating Instruction Manual
15
① When you use the atomizer, it should be placed below the disinfectant surface;
② When you use the atomizer, the disinfectant surface should be 1-1.5cm higher than
the red water-break protection switch of the atomizer;
③ When the atomizer is taken out of the disinfectant, it should be cut off the electricity
before being used, or the red water-break protection switch makes it above the surface,
avoiding the atomizer plate burn dry;
④ When the disinfectant in water tank is little, we need to change the disinfectant in
time or let the liquid flow, avoiding the high temperature causing the atomizer over
heated protection.
VIII. Maintenance of Equipment
1. This product just need the general maintenance, surface cleaning and periodical
inspection, the time period is month. At the same time when you use the equipment,
you need a long-term and comprehensive consideration.
2. Clean the tank body regularly. If the dust is heavy in the surrounding space, the
period of cleaning space should be as short as possible; during the cleaning, avoiding
touching the electrical equipment such as the electric wire.
3. Should do the cleaning and disinfection for the floor and hand washer traytermly.
4. Check regularly whether the hand washer has the electricity, replace the battery in
time.
5. Check regularly whether the air outlet of the atomizing sterilizer is fluent, clean the
sludge in time.
Operating Instruction Manual
16
IX. Filling instruction
1. Filling the hand disinfectant
① As shown above, open the hand disinfection machine with the random matching key,
rive the hand disinfection machine storage lid, and do the filling.
② Using the VBK degerming water is suggested.
2. Filling the atomizer
Filling Point
① As shown above, open the atomizer’s lid with the random matching key, do the filling
directly;
② Pay attention to see if the floating borad float, don’t be stuck in it;
③ When the liquid surface is too low it will give the audible alarm, which means that the
disinfectant will run out soon;
① Add 24L disinfectant once can keep it working for 8 hours;
② Not suggest to use the 84 disinfectant (highly corrosive)and alcohol
disinfectant(Atomization is flammable and explosive).
Operating Instruction Manual
17
X. ECOPRO ANMO Intelligent Anti-Epidemic Monitoring Workstation
warranty card
1. Warranty policy
(1) ECOPRO ANMO Intelligent Anti-Epidemic Monitoring Workstation series products
has one-year product warranty period, each part’s warranty period is one year. During
this period, depending on this instruction, the users can dial the 24 hours service hotline
to connect with the ECOPRO Maintenance Workstation to deal with the On-site
installation commissioning/ after-sales maintenance business
(2) The warranty period is calculated from the date the users install and debug the
equipment.
(3) If the product exists any problem not in accordance of the contract caused by the
missing or misloading during the production process, the users can dial the 24 hours
service hotline within 7 days after the install to put forward the returning or replacing
goods application to the ECOPRO company, our company will deal with it according to
the relevant regulation.
2. Non-warranty clause
(1) If exceed the warranty period, not offering warranty;
(2) If the users alter or refit any spare part or wiring harness without permission, the
malfunction caused by altering the fuse model and specification, the malfunction
caused by the users’ own reason, they are not under the warranty of ourcompany;
(3) The damage or later relevant malfunction caused by Force Majeure(such as the
flood, earthquake, fire disaster, hail disaster, storm, air dust, chemical corrosion caused
by acid rain, etc), they are not under the warranty of our company.
3. 24 hours service hotline (install and debug/after-sales repair please dial
this hotline number. 400-855-0715