ecoscape clarity composite decking slip test results€¦ · low slip potential 36+ safe 1/4”...

2
LOW SLIP POTENTIAL 36+ SAFE 1/4” Groove (D) 1/4” Groove (W) 1” Groove (W) 1” Groove (D) 100% 100% 100% 94% 34 52 52 53 PTV Slip Test BS 7976-2:2002 (Four S / Slider 96) Ecoscape Clarity Composite Decking Slip Test Results The above TRL Pendulum tests were carried out in accordance with the procedure detailed in BS7976 part 2:2002 and the UK Slip Resistance Group Guidelines, Issue 3. The Pendulum was shod with Four S rubber / Slider 96 and tests conducted in both wet and dry conditions. The planks were tested in 3 directions; along, across and at a 45 degree angle to previous direction. Both surfaces were tested. For commercial application 1 person in 10,000 requires a minimum PTV of 34 for saftey. NB: Based on BRE work and is for turning as well as straight walking Ecoscape UK Ltd., Company Reg: 08530988 0845 9011 988 | www.ecoscapeuk.co.uk | [email protected]

Upload: others

Post on 22-Aug-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Ecoscape Clarity Composite Decking Slip Test Results€¦ · LOW SLIP POTENTIAL 36+ SAFE 1/4” Groove (D) 1/4” Groove (W) 1” Groove (W) 1” Groove (D) 100% 100% 100% 38 100%

LOW SLIP POTENTIAL 36+ SAFE

1/4” Groove (D)

1/4” Groove (W)

1” Groove (W)

1” Groove (D) 100%

100%

100%

94%34525253

PTV Slip Test BS 7976-2:2002

(Four S / Slider 96)

Ecoscape Clarity Composite Decking Slip Test Results

The above TRL Pendulum tests were carried out in accordance with the procedure detailed in BS7976 part 2:2002 and the UK Slip Resistance Group Guidelines, Issue 3.The Pendulum was shod with Four S rubber / Slider 96 and tests conducted in both wet and dry conditions. The planks were tested in 3 directions; along, across and at a 45 degree angle to previous direction. Both surfaces were tested.

For commercial application 1 person in 10,000 requires a minimum PTV of 34 for saftey. NB: Based on BRE work and is for turning as well as straight walking

Ecoscape UK Ltd., Company Reg: 085309880845 9011 988 | www.ecoscapeuk.co.uk | [email protected]

Page 2: Ecoscape Clarity Composite Decking Slip Test Results€¦ · LOW SLIP POTENTIAL 36+ SAFE 1/4” Groove (D) 1/4” Groove (W) 1” Groove (W) 1” Groove (D) 100% 100% 100% 38 100%

LOW SLIP POTENTIAL 36+ SAFE

1/4” Groove (D)

1/4” Groove (W)

1” Groove (W)

1” Groove (D) 100%

100%

100%

100%38663767

PTV Slip Test BS 7976-2:2002

(TRL / Slider 55)

The above TRL Pendulum tests were carried out in accordance with the procedure detailed in BS7976 part 2:2002 and the UK Slip Resistance Group Guidelines, Issue 3.The Pendulum was shod with Four S rubber / Slider 96 and tests conducted in both wet and dry conditions. The planks were tested in 3 directions; along, across and at a 45 degree angle to previous direction. Both surfaces were tested.

For commercial application 1 person in 10,000 requires a minimum PTV of 34 for saftey.

NB: Based on BRE work and is for turning as well as straight walking

Ecoscape UK Ltd., Company Reg: 085309880845 9011 988 | www.ecoscapeuk.co.uk | [email protected]