edison stp-a52j05gs7-200830214647.x
TRANSCRIPT
Footnotes
Rev. Date: 27/10/11
Notes:13.7"
[ 348mm ]
4.6"[118mm ]
31.5"[ 800mm ]
Light Engine
Cover
Latches(Tool-less Entry)
Housing
NOTE: All data subject to change without notice.
810
SVSilver 3
BKBlack 3
BZBronze 3
PBPlatinum Bronze 3
WHWhite 3
ULUniversal 120–277V
UHUniversal 347–480V
Product Family Optic Mounting # of LEDs LED Voltage Color Drive Factory-Installed Options ( x 12 ) Series Options Current Please type additional options in manually on the lines provided above.
43K 4300K Color Temperature 4
DIM 0–10V Dimming 5,6,7
R NEMA Photocell Receptacle 10
700700mA
(Standard)525
525mA350
350mA
STP A52J05G HTVT
2
LED PERFORMANCE SPECS
PRDNo.
B U G Initial Delivered Lumens
Medium @ 4300K
Initial Delivered Lumens
Medium @ 6000K
B U G total ledsPowerWatts
LimitCurrent DC
Total Current@ 240V
Total Current@ 277V
Total Current@ 347V
Total Current@ 480V
L70 Hours*
@ 25º C (77º F)
50K Hours Lumen Maintenance
Factor*
@ 15º C (59º F)Rating** Rating** ** ** ** **
350mA Fixture Operating at 25º C (77º F) Recommendation Driver Meanwell HLG185-2494%143 10,780 (8) 1 4 3 4 3 2 108 5.6 0.48 0.42 0.33 0.24 > 150,000
144 16,240 (10) 1 4 4 4 3 2 140 7.8 0.64 0.59 0.49 0.35 > 150,000500mA Fixture Operating at 25º C (77º F) Recommendation Driver Meanwell HLG240-24
92%143 14,700 (8) 1 4 3 4 3 2 140 7.7 0.74 0.65 0.51 0.37 133,000144 19,600 (10) 1 4 4 4 3 2 180 10.0 0.79 0.72 0.75 0.55 129,000
700mA (Standard) Fixture Operating at 25º C (77º F) Recommendation Driver Meanwell HLG320-2490%143 19,110 (8) 1 4 3 4 3 3 180 11.2 0.99 0.86 0.69 0.49 109,000
144 24,080 (10)
9,163 (8) 13,464 (10)
12,495 (8) 18,360 (10)
16,244 (8) 23,868 (10)1 4 4 5 3 3 200 14.0 1.26 1.17 1.01 0.73 102,000
* For recommended lumen maintenance factor data see TD-13 ** For more information on the IES BUG (Backlight-Uplight-Glare) *** All current must be add 10% +PF, H type for higher than 277V
Edison Streetlight
1. IESNA Type V Medium distribution2. Horizontal tenon mount3. Light engine portion of extrusion is not painted and will remain
natural aluminum regardless of color selection4. Color temperature per �xture; 6000K standard; minimum 70 CRI5. Control by others6. Refer to dimming spec sheet for availability and additional
information7. Can't exceed the speci�ed drive current. Consult factory if
exceeding the drive current is necessary
8. Refer to multi level spec sheet for availability and additional information
9. Sensor not included
10. Photocell by others 11. Includes exterior wattage label that re�ects watts for the drive
current selected. The ability to exceed the selected drive current will be disabled.
1S 135x75
2S 130x40
1N 130x50
1 S7
27.9"[ 710mm ]
UTL Utility Option 11
HL Hi/Low (175/350/525, dual circuit input) 8,9
200830214647.x
200830214647.x
Rev. Date: 27/10/11 Edison Streetlight
Photometrics
General DescriptionFixture housing is all aluminum construction. Standard �xture utilizes terminal block for power input suitable for #2–#14 AWG wire and operates at 700mA. Drive current is �eld switchable. Fixture is designed to mount on 1.25" IP (1.66" [42mm] O.D.) and/or 2" (51mm) IP (2.375" [60mm] O.D.) horizontal tenon (minimum 8" [203mm] in length).Fixture carries a limited �ve year warranty.
ElectricalModular design accommodates varied lighting output from high power, white, 6000K (+/- 500K per full �xture), minimum 70 CRI, long life LED sources. Optional 4300K (+/- 300K per full �xture) also available. 120–277V 50/60 Hz, Class 1 LED drivers are standard. 347–480V 50/60 Hz option is available. LED drivers have power factor >90% and THD <20% at full load. Quick disconnect harness suitable for mate and break under load provided on power feed to driver for ease of maintenance. Units provided with integral 10kV surge suppression protection standard. Surge protection tested in accordance with IEEE/ANSI C62.41.2.
Independent Testing Laboratories certi�ed test. Report No. ITL66915. Candlepower trace of 6000K, 12 LED EdisonStreetlight luminaire with IESNA Type I Long distribution. Luminaire with 1,314 initial delivered lumens operating at 350mA. All published luminaire photometric testing performed to IESNA LM-79-08 standards.
120º120º
90º 90º
60º60º
30º 30º
150º 150º
50
25
75
100
Candlepower Trace: Vertical plane throughhorizontal angle of maximum candlepower
Independent Testing Laboratories certi�ed test. Report No. ITL66915. Candlepower trace of 6000K, 12 LED EdisonStreetlight luminaire with IESNA Type I Long distribution. Luminaire with 1,314 initial delivered lumens operating at 350mA. All published luminaire photometric testing performed to IESNA LM-79-08 standards.
120º120º
90º 90º
60º60º
30º 30º
150º 150º
50
25
75
100
Candlepower Trace: Vertical plane throughhorizontal angle of maximum candlepower
Independent Testing Laboratories certi�ed test. Report No. ITL66915. Candlepower trace of 6000K, 12 LED EdisonStreetlight luminaire with IESNA Type 2 Long distribution. Luminaire with 1,314 initial delivered lumens operating at 350mA. All published luminaire photometric testing performed to IESNA LM-79-08 standards.
120º120º
90º 90º
60º60º
30º 30º
150º 150º
50
25
75
100
Candlepower Trace: Vertical plane throughhorizontal angle of maximum candlepower
1S 135°x75° 1S 130°x50° 1S 130°x40°