Education You Can Build On
Wiring / Installation
Emerson Blue Easy Reader 1F95EZ-0671
Heat Pump / Dual Fuel Staging Detail
2nd Stage:
HP1Heat Mode
3rd Stage:
HP1Heat Mode
1st Stage: Emergency Mode 2nd Stage: Emergency Mode
3rd Stage: HP2 – Heat Mode 4th Stage: HP2 – Heat Mode
1st Stage: Emergency Mode 2nd Stage: Emergency Mode
W/E W2
Dual fuel option de-energizes any compressor stage when auxiliary heat is energized.
Terminal Designations (Wiring)
Terminal Description SS1 MS2 HP1 HP2O/B Reversing Valve x x
Y2 2nd Stage Compressor x x
Y1 1st Stage Compressor x x x x
G Fan Relay x x x x
RC Power for Cooling x x x x
RH Power for Heating x x x x
C Common Wire x x x x
W/E1st Stage Heat or Aux Heat for HP2 x x x x
W22nd Stage Heat MS2 or 4th Stage Heat HP2 x x
L Diagnostics (Optional)
Wiring for Conventional Systems(Non-Heat Pump)
*
*For two transformer systems remove the jumper Common connection optional – required for diagnostic indicator
Single Stage (SS) in YellowMulti-Stage (MS) add Blue
Y2Y W/E W2 G RH RC C
#6 Terminal is for a power closed 3 wire zone valve
Wiring for Heat Pump SystemsHeat Pump (HP1) in YellowHeat Pump (HP2) add Blue
Y2YO/B G*W/E C*W2
Common connection required for diagnostic or malfunction indication.
Dual Fuel option, if selected turns off compressor(s) when Auxiliary stages energizes.