electrical distribution products - · pdf fileelectrical distribution products contractor...
TRANSCRIPT
IndustrialOEM (Original Equipment Manufacturer)ConstructionCommercialGovernmentOil & Gas
Markets We ServeDeliveryEmergency ServicesRecycling ServicesReturn PolicyInventory Management Solutions (IMS)Technical & Product SpecialistsWeb Order EntryTraining
Services We Provide
Our History• Over 90 years of servicing electrical needs for all markets.
• It began in 1924 when Schaedler Brothers was created by Harry, Andrew, and William Schaedler, a sibling partnership that started simply with the purchasing, plating, assembling, and selling of light fixture parts.
• Twenty years later, Motter Electric Company was incorporated to distribute electrical supplies. In 1956, Motter officially changed its name to York Electrical Supply Company (YESCO).
• In 1999, Schaedler Brothers, Inc., and YESCO merged, creating what to this day is the largest electrical distributor headquartered in Central Pennsylvania.
• As part of our heritage, we have developed the same capabilities of a large chain, but continue to operate as your neighborhood supplier with a personal touch. We invite you to try all of our services from basic to specialty.
Schaedler Yesco Distribution, Inc. is a leading electrical distributor of top-quality products from preferred manufacturers of electrical, automation, lighting, data communication, energy, and oil and gas supplies. We pride ourselves on offering a variety of products from brands you trust that fit your current need and budget.
We make every effort to monitor and adjust our product selection and inventory requirements so you have access to what you need, when you need it. Our convenient locations, will-call counter pick-ups, and vast delivery vehicle fleet ensure the fast turnaround you would expect from a preferred business partner.
www.sydist.com • 1-800-998-1621
Our MissionTo enhance our customers’ performance and profitability by being the leading provider of distributor services and solutions.
4 www.sydist.com/SiemensMurray 4 www.sydist.com
Safety SwitchesGeneral Duty
General Duty Safety Switches
240V Fusible 2P, 2F, and Neutral 240V AC / 250V DC
Ampere Rating
Indoor Type 1 Catalog Number
Outdoor Type 3R Catalog Number
30 GF221N GF221NR
60 GF222N GF222NR
100 GF223N GF223NR
200 GF224N GF224NR
400 GF225NH GF225NRH
400 GF225N GF225NR
600 GF226NH GF226NRH
600 GF226N GF226NR
3P, 3F, and Neutral 240V AC / 250V DC
Ampere Rating
Indoor Type 1 Catalog Number
Outdoor Type 3R Catalog Number
30 GF321N GF321NR
60 GF322N GF322NR
100 GF323N GF323NR
200 GF324N GF324NR
400 GF325NH GF325NRH
400 GF325N GF325NR
600 GF326NH GF326NRH
600 GF326N GF326NR
240V Non-Fusible 2P or 3P 240V AC / 250V DC
Ampere Rating
Indoor Type 1 Catalog Number
Outdoor Type 3R Catalog Number
30 GNF321 GNF321R
60 GNF322 GNF322R
100 GNF323 GNF323R
200 GNF324 GNF324R
400 GNF325HNF365R Use 600V Switch
600 GNF326HNF366R Use 600V Switch
These switches are UL listed for application on grounded B-phase systems. Suitable for use on 3-phase motor loads. Service entrance rated. Height reduced switches (45.25" rather than 56" in height) for use with 500MCM or smaller conductors. Also for 60A, 240V General Duty and Heavy Duty. Provides 1 normally open and 1 normally closed contact.g GD = General Duty, HD = Heavy Duty
Class R Fuse Clip Kits
Catalog Number Description
GSRK321 Class R Fuse Clip Kit (30A General Duty Only)
HR21 Class R Fuse Clip Kit (30A, 240V Heavy Duty Only)
HR612 Class R Fuse Clip Kit (30A, 600V / 60A, 240V)
HR62 Class R Fuse Clip Kit (60A, 600V)
HR63 Class R Fuse Clip Kit (100A)
HR64 Class R Fuse Clip Kit (200A)
HR656 Class R Fuse Clip Kit (400A / 600A)
Neutral Kits
Description Kit Catalog Number
30 GD W410190
30 HD. 60 GD HN612 g
60, 100 HD, 100 GD HN623 g
200 HN64
400 & 600 HN656
800 & 1200 HN678
Equipment Ground Kits
Switch Ampere Rating
Catalog Number
Number Of Terminals
Wire Range Per Terminal (Cu/Ai)
30A GD GSGK60 2 #14-8 AWG
60-200GD HG61234 2 #14-4 AWG
30-200 HD HG61234 2 #14-4 AWG
400 & 600 HG656 4 #14-2/0 AWG
800-1200 HG678 8 #6 AWG-250 Kcmil
Auxiliary Contacts
Switch Ampere
Aux. Switch Catalog Number
Kit Ampere Rating Horsepower Rating
125V AC-Max.
250V AC Max.
28V Dc Max.
125V AC Max.
250V AC Max.
With 1 NO & 1 NC Isolated Contacats
30-200 HA161234 10 10 7 1/2 3/4
400-1200 HA165678 10 10 – 1/2 3/4
Accessories (General and Heavy Duty)
www.sydist.com/SiemensMurray 55www.sydist.com
Safety SwitchesHeavy Duty
Heavy Duty Safety Switches600V Fusible
2P, 2F 480V AC / 600V AC / 600V DC
Ampere Rating
Indoor Type 1 Catalog Number
Outdoor Type 3R Catalog Number
30 HF261 HF261R
60 HF262 HF262R
100 HF263 HF263R
400 HF265 HF265R
600 HF266 HF266R
3P, 3F 480V AC / 600V AC / 250V DC
Ampere Rating
Indoor Type 1 Catalog Number
Outdoor Type 3R Catalog Number
30 HF361 HF361R
60 HF362 HF362R
100 HF363 HF363R
200 HF364 HF364R
400 HF365H HF365RH
400 HF365 HF365R
600 HF366H HF366RH
600 HF366 HF366R
800 HF367 HF367R
1200 HF368 HF368R
3P, 3F, and Neutral 480V AC / 600V AC / 250V DC
Ampere Rating
Indoor Type 1 Catalog Number
Outdoor Type 3R Catalog Number
30 HF361N HF361NR
60 HF362N HF362NR
100 HF363N HF363NR
200 HF364N HF364NR
400 HF365N HF365NR
600 HF366N HF366NR
800 HF367N HF367NR
1200 HF368N HF368NR
600V Non-Fusible
2P 480V AC / 600V AC / 600V DC
Ampere Rating
Indoor Type 1 Catalog Number
Outdoor Type 3R Catalog Number
30 HNF261 HNF261R
60 HNF262 HNF262R
100 HNF263 HNF263R
400 HNF265 HNF265R
600 HNF266 HNF266R
Heavy Duty Safety Switches600V Non-Fusible
3P 480V AC / 600V AC / 250V DC
Ampere Rating
Indoor Type 1 Catalog Number
Outdoor Type 3R Catalog Number
30 HNF361 HNF361R
60 HNF362H HNF362RH
60 HNF362 HNF362R
100 HNF363 HNF363R
200 HNF364 HNF364R
400 HNF365 HNF365R
600 HNF366 HNF366R
800 HNF367 HNF367R
1200 HNF368 HNF368R
Built to order. Allow 3 - 5 weeks for delivery. Suitable for use as service entrance equipment except for 1200 when used on a 480 or 600V grounded wye system. Use 3-Pole switch for 200A application. Compact switch (11.1”H, 6.6”W box less cover and handle). Short circuit withstand rating—100,000 RMS sym. amps. 60-200A 3-Pole switches are also rated 600V DC. Height reduced switch (45.25 rather than 56 inches in height) for use with 500MCM or smaller conductors. Hubs suitable for 3R switches.
Hubs Type 3R
Conduit Size (Inches) Catalog Number Used On
Cover ECHA000
30A GD Only3/4 ECHA075
1 ECHA100
1 1/4 ECHA125
Cover ECHS000
60–200A GD30–200A HD
3/4 ECHS075
1 ECHS100
1 1/4 ECHS125
1 1/2 ECHS150
2 ECHS200
2 1/2 ECHS250
2 1/2 ECHV250
400–1200A3 ECHV300
3 1/2 ECHV350
4 ECHV400
6 www.sydist.com/SiemensMurray 6 www.sydist.com
New Revised P1 Unassembled Panelboards
Flexibility and ease of assembly:Customer oriented design creates installation convenience. For all of its one-of-a-kind features, the P1 panelboard is also designed to be extremely userfriendly. For instance, field convertible main breaker and main lug kits, (through 400 amps), will allow you to switch from main lug to main breaker, and vice versa with no change in box size or additional cabling. Plus, lay-in construction (for 250 A CU) and/or removable lugs make wiring the main and neutral lugs easier and faster. To further speed
1) Completely symmetrical boxes may be mounted with either end up. There are two pre-punched equipment ground connector locations for contractor friendly installation.
2) Box comes pre-punched for optional, field installable door-in-door or hinged style trims. There are also two pre-punched ground connector locations. The panel box will accept both standard ground connector (EGK and ECGK) assemblies and insulated ground connector kits (IGK and ICGK).
3) Interior is completely symmetrical allowing it to be changed from top to bottom feed by simply rotating the interior.
4) Choose either a Main Breaker kit or Main Lug kit with which to terminate your incoming cables. Main lug kits are contractor friendly lugs through 350 kcmil (250 amp panel) or (1) 600 kcmil or (2) 250 kcmil connectors for 400 amp panels. No line connectors in the P1 panel require multiple wires under one screw. Main Breaker kits (250 amps and below) are horizontally mounted allowing field convertible top or bottom feeds to
To better serve the needs of customers, Authorized Siemens Unassembled Panelboard Distributors offer product flexibility, quicker job turn-around, and affordable pricing. All Siemens unassembled panelboards are fully backed for high quality, trouble-free operation and are labeled as Suitable for use as Service Entrance Equipment.
wiring, as well as reduce clutter, the P1 panel also features a split neutral design and branch neutral connections which are closer to the breakers than competitors. Additionally, field addable sub-fed breakers (up to 250 amps) or feed through lug kits can be field installed without utilizing any of your feeder breaker positions or increasing your box height. Furthermore, the unique design allows the panel to be inverted in the field and keep its labeling legible.
be performed easily. MLO kits and Main Breaker Kits are interchangeable and can be changed/added in the field without making changes to the enclosure or interior.
5) Branch neutral connections are near the breaker connections to speed wiring and reduce clutter. The standard P1 neutral is rated for 100% of the panel’s ampacity and will accept copper or aluminum wire. Optional 200% and 2/0 neutrals are also available.
6) The panel includes space to add (1) sub-feed breaker (max 250 amps), feed-thru lugs or TPS3 (SPD) kit.
7) Siemens standard trim has hidden hinges and mounting hardware for added safety. The rounded door corners not only enhance the panel’s appearance but also help to eliminate injuries caused from sharp corners.
8) Semi-flush lock comes standard. Easily identified locked position denoted by keyway being horizontal when door has been locked.
1
2
3 4
7
8
5
6
www.sydist.com/SiemensMurray 77www.sydist.com
Catalog Numbering SystemUnassembled Panelboards
Note: Revised P1 was introduced in June 2014. All original P1 devices do not include the "Subfeed Space" Indicator. All original P1 included the Subfeed Space as standard.
Type of PanelP1
Voltage and SystemX = 208Y/120, 3-Phase 4-Wire A = 120/240V, 1-Phase 3-Wire E = 480Y/277V, 3-Phase 4-Wire 7 = xGB interior, 480Y/277V, 3-Phase 4-Wire
Circuits18, 30, 42, 54* (*Revised P1 only)
Mains MC = Convertible mainsSelect Main Lug Kit or Breaker Mounting Kit from page ?
Amperage 400A max (typically 250A or 400A)
Main Bus MaterialA = Aluminum C = Copper
Note: Standard bussing in P1 panels is tin plated for aluminum and copper.Standard bus is temperature rated to the maximum amperage in the panel.
Branch BreakersPanel Type Voltage (Max.) Breaker Type Additional Information
P1, Revised P11
240 BL, BLH, HBL, BQD, NGB, HGB, LGBSee Page 17480 / 277 BQD, NGB, HGB, LGB,
600 / 347 3 BQDG 2, NGB, HGB, LGB
1 ConsultsalesofficeforavailabilityofCSA. 2 See Speedfax for additional information. 3 600/347V options are not available in a UPB panel - see factory assembled section.
Type P1 unassembled panelboards are completely convertible from main lug to main breaker and vice-versa. Additionally feed-thru lugs, or subfeed circuit breakers up to 400 ampere can be added without increasing the box height for Revised P1 with “T” suffix, see the chart.
1. Compute total number of poles to determine interior catalog number. (Note: BL / BQD (or) xGB Main Breaker will use unit space. The total number of poles should include 2 (or) 3 poles for 1-phase (or) 3-phase mains.)
2. List catalog number and price of interior, box and front.
3. Select main lug kit or main breaker kit from appropriate tables.
Note: Main/Subfeed Breaker mounting kits may be ordered with or without breakers included, see page 5 and 6 for selection.
4. List required branch circuit breakers and filler plates to cover any unused positions.
5. Select any modifications or accessories.
P 1 X 1 8 M C 2 5 0 A T
Subfeed Space Indicator (for Revised P1 only) T = Subfeed Space Included
8 www.sydist.com/SiemensMurray 8 www.sydist.com
Distributor StockType P1 Panelboards
Product Category UPB
Type P1 Unassembled Panelboards (Revised P1 introduced 2014)
Pricing An Unassembled Panel400A Max. — 20" Wide x 5.75" Deep 1. Choose the appropriate Interior from the
table below.2. Choose the Main Device: Main Lugs from page
16, Main Breaker Kit from pages 16 - 17 and Main Breakers from Section 7.
Front included in NEMA 3R and 3R/12 Box.
3. Choose Branch Breakers. BL, BQD and xGB breakers from Section 7.
4. Choose Feed-Thru Lugs or Subfeed Breaker Kit from pages 16 - 17 and Subfeed Breaker from Section 7.
AmpsMax. # of Poles
Original InteriorCatalog Number
Revised P1 Interior Catalog Number Box Size
Type 1 Encl.
Type 3R/12
Encl.Type 1 Front Surface
Type1 Front Flush
Convertible Mains — 1-Phase, 3-Wire 120/240V
25018 P1A18MC250A P1A18MC250AT 32 B32 WP32 S32B F32B30 P1A30MC250A P1A30MC250AT 38 B38 WP38 S38B F38B42 P1A42MC250A P1A42MC250AT 44 B44 WP44 S44B F44B54 P1A54MC250AT 50 B50 WP50 S50B F50B
400
18 P1A18MC400A — — — — — —30 P1A30MC400A P1A30MC400AT 62 B62 WP62 S62B F62B42 P1A42MC400A P1A42MC400AT 68 B68 WP68 S68B F68B54 P1A54MC400AT 74 B74 WP74 S74B F74B
250
18 P1A18MC250C P1A18MC250CT 32 B32 WP32 S32B F32B30 P1A30MC250C P1A30MC250CT 38 B38 WP38 S38B F38B42 P1A42MC250C P1A42MC250CT 44 B44 WP44 S44B F44B54 P1A54MC250CT 50 B50 WP50 S50B F50B
40018 P1A18MC400C — — — — — —30 P1A30MC400C P1A30MC400CT 62 B62 WP62 S62B F62B42 P1A42MC400C P1A42MC400CT 68 B68 WP68 S68B F68B54 P1A54MC400CT 74 B74 WP74 S74B F74B
Convertible Mains — 3-Phase, 4-Wire 208Y/120V
25018 P1X18MC250A P1X18MC250AT 32 B32 WP32 S32B F32B30 P1X30MC250A P1X30MC250AT 38 B38 WP38 S38B F38B42 P1X42MC250A P1X42MC250AT 44 B44 WP44 S44B F44B54 P1X54MC250AT 50 B50 WP50 S50B F50B
40018 P1X18MC400A — — — — — —30 P1X30MC400A P1X30MC400AT 62 B62 WP62 S62B F62B42 P1X42MC400A P1X42MC400AT 68 B68 WP68 S68B F68B54 P1X54MC400AT 74 B74 WP74 S74B F74B
25018 P1X18MC250C P1X18MC250CT 32 B32 WP32 S32B F32B30 P1X30MC250C P1X30MC250CT 38 B38 WP38 S38B F38B42 P1X42MC250C P1X42MC250CT 44 B44 WP44 S44B F44B54 P1X54MC250CT 50 B50 WP50 S50B F50B
40018 P1X18MC400C — — — — — —30 P1X30MC400C P1X30MC400CT 62 B62 WP62 S62B F62B42 P1X42MC400C P1X42MC400CT 68 B68 WP68 S68B F68B54 P1X54MC400CT 74 B74 WP74 S74B F74B
Convertible Mains — 3-Phase, 4-Wire 480Y/277V
25018 P1E18MC250A P1E18MC250AT 32 B32 WP32 S32B F32B30 P1E30MC250A P1E30MC250AT 38 B38 WP38 S38B F38B42 P1E42MC250A P1E42MC250AT 44 B44 WP44 S44B F44B54 P1E54MC250AT 50 B50 WP50 S50B F50B
40018 P1E18MC400A — — — — — —30 P1E30MC400A P1E30MC400AT 62 B62 WP62 S62B F62B42 P1E42MC400A P1E42MC400AT 68 B68 WP68 S68B F68B54 P1E54MC400AT 74 B74 WP74 S74B F74B
25018 P1E18MC250C P1E18MC250CT 32 B32 WP32 S32B F32B30 P1E30MC250C P1E30MC250CT 38 B38 WP38 S38B F38B42 P1E42MC250C P1E42MC250CT 44 B44 WP44 S44B F44B54 P1E54MC250CT 50 B50 WP50 S50B F50B
40018 P1E18MC400C — — — — — —30 P1E30MC400C P1E30MC400CT 62 B62 WP62 S62B F62B42 P1E42MC400C P1E42MC400CT 68 B68 WP68 S68B F68B54 P1E54MC400CT 74 B74 WP74 S74B F74B
Interiors for xGB Breakers — 3-Phase, 4-Wire 480Y/277V
25018 P1718MC250A P1718MC250AT 32 B32 WP32 S32B F32B30 P1730MC250A P1730MC250AT 38 B38 WP38 S38B F38B42 P1742MC250A P1742MC250AT 44 B44 WP44 S44B F44B54 P1754MC250AT 50 B50 WP50 S50B F50B
40018 P1718MC400A — — — — — —30 P1730MC400A P1730MC400AT 62 B62 WP62 S62B F62B42 P1742MC400A P1742MC400AT 68 B68 WP68 S68B F68B54 P1754MC400AT 74 B74 WP74 S74B F74B
25018 P1718MC250C P1718MC250CT 32 B32 WP32 S32B F32B30 P1730MC250C P1730MC250CT 38 B38 WP38 S38B F38B42 P1742MC250C P1742MC250CT 44 B44 WP44 S44B F44B54 P1754MC250CT 50 B50 WP50 S50B F50B
40018 P1718MC400C — — — — — —30 P1730MC400C P1730MC400CT 62 B62 WP62 S62B F62B42 P1742MC400C P1742MC400CT 68 B68 WP68 S68B F68B54 P1754MC400CT 74 B74 WP74 S74B F74B
42 circuit with Back-fed Main
54 circuit 400A
www.sydist.com/SiemensMurray 99www.sydist.com
Distributor StockType P1 Panelboards
Product Category UPB
Miscellaneous Parts and AccessoriesCatalog # DescriptionBK1 Bonding Kit for 250A max. Original P1 PanelsBK1A Bonding Kit for 250A max. Revised P1 PanelsBK2 Bonding kit for S1/S2 400 & 600BK3 Bonding kit IMK1 Interior Adjusting Kit11-1824-01 Directory Card Holder12-1110-01 Directory Card11-1056-01 NEMA Instruction Book
NBK03 Number Strips 1–42. Stick-on type; Use w/ P1 series Panels
NBK04 Number Strips 43–84. Stick-on type; Use w/ P1 series Panels
NBK05 Number Strips 85–126. Stick-on type; Use w/ P1 series Panels
NBK06 Number Strips 127–168. Stick-on type; Use w/ P1 series Panels
EGK AL Ground Bus 44 ConnectionsECGK CU Ground Bus 44 ConnectionsIGK Insulated AL Ground BusICGK Insulated CU Ground BusEWK1 End Wall Kit with Knockouts (20" W x 5.75" DP)EWK2 End Wall Kit with Knockouts (24" W x 7.75" DP)EBF1 NEB/HEB Filler PlateP1SCRWS Package of 42 breaker mounting screws for P1
DFFP1 1" Branch circuit filler plate (suitable for replacing QF3 in P1 thru P5 Panelboards and Switchboards)
P1CONBPHCU Connector kit – 6 pcs. B-phase CopperP1CONBPHAL Connector kit – 6 pcs. B-phase AluminumP1CONACPHCU Connector kit – 6 pcs. A or C-phase CopperP1CONACPHAL Connector kit – 6 pcs. A or C-phase Aluminum
Lug Kits — Main or Feed Thru
Breaker Mounting Kits — Main or Subfeed Strap Kit w/o Breaker
AmpereRating Breaker Types Service
Original P1 Catalog Number
Revised P1 Catalog Number
100A BQD 3-Phase MBKBC3 Use Back-fed Main Label Kit # MBKBFA (includes Neutral Lug, "MAIN" label and instructions)
100A BL, BLH, HBL 1-Phase MBKBL13-Phase MBKBL3
125A NGB, HGB, LGB1-Phase MBKNB13-Phase MBKNB3
125A ED4, ED6, HED4, HED6 1-Phase MBKED1 MBKED1A3-Phase MBKED3 MBKED3A
225A QJ2, QJH2, QJ2-H 1-Phase MBKQJ1 MBKQJ1A3-Phase MBKQJ3 MBKQJ3A
250A FXD6, FD6, HFD6, HFXD6 1-Phase MBKFD1 MBKFD1A3-Phase MBKFD3 MBKFD3A
400A JXD2, JD6, JXD6,HJD6, HJXD6
1-Phase MBKJD1 MBKJD1A3-Phase MBKJD3 MBKJD3A
400 amp kit is for main only — not allowed for subfeed breaker. Back-fed main occupies branch space.
Copper Neutral Lug Kits — 250A
Numberof Circuits Description
Original P1 Catalog Number
Revised P1 Catalog Number
182 or 4 Branch Neutral Strips, 1 Main Neutral Lug, Hardware
CNKL18 Use 30 ckt kit30 CNKL30 CNLK30A42 CNKL42 CNLK42A54, 66 — CNLK54A
2/0 Neutral Lug Kits — 250A and 400A18
2 or 4 Branch Neutral Strips, 1 Main Neutral Lug, Hardware
— Use 30 ckt kit30 — LNLK30A42 — LNLK42A54, 66 — LNLK54A
200% Neutral Lug Kits/250A18
2 or 4 Branch Neutral Strips, 1 Main Neutral Lug, Hardware
2NLK18 Use 30 ckt kit30 2NLK30 2NLK30A42 2NLK42 2NLK42A54, 66 — 2NLK54A
200% Neutral Lug Kits/400A18
2 or 4 Branch Neutral Strips, 1 Main 600MCM Neutral Lug, Hardware
42NLK18 Use 30 ckt kit30 42NLK30 42NLK30A42 42NLK42 42NLK42A54, 66 — 42NLK54A
Replacement Parts Only
MBKQJ3A
MBKFD3A
Amp Rating Matl.
Wire Range (includes Neutral) Service
Original Catalog Number
Revised P1 Catalog Number
250AL (1) #6 AWG-
350 kcmil (CU or AL)1 Phase MLKA1 MLKA1A3 Phase MLKA3 MLKA3A
CU (1) #6 AWG- 350 kcmil (CU or AL)
1 Phase MLKC1 MLKC1A3 Phase MLKC3 MLKC3A
400AL (2) 1/0 - 250 kcmil
or (1) #2 AWG-600 kcmil1 Phase 4MLKA1 4MLKA1A3 Phase 4MLKA3 4MLKA3A
CU (2) 1/0 - 4/0 or (1) 1/0 - 600 kcmil
1 Phase 4MLKC1 4MLKC1A3 Phase 4MLKC3 4MLKC3A
400 AL AL 1/0-750 kcmil (max. 600 kcmil CU wire)
1 Phase – 4MLKA1B3 Phase – 4MLKA3B
10 www.sydist.com/SiemensMurray 10 www.sydist.comProduct Category UPB
Selection Guide1. Select breaker type.2. Select required amperage.3. Select number of poles.4. Select branch breaker catalog
numbers.5. Select ground bar and filler
plates. (See replacement parts & accessories on Page 15.)
Branch Breakers Selection for P1
AFCI – Combination Type Arc Fault Circuit Interrupter
Breaker Type
Ampere Rating
Catalog Number
Interrupting Ratings (kA) RMS Symmetrical AmperesVolts AC120 120/240 240
BAF2 1-pole
15 B115AFC 10 — —20 B120AFC 10 — —
BAFH2 1-pole
15 B115AFCH 22 — —20 B120AFCH 22 — —
HBAF2 1-pole
15 BA115AFCHH 65 — —20 BA120AFCHH 65 — —
BAF2-pole
1520
B215AFCB220AFC
1010
——
——
BAFH2-pole
1520
B215AFCHB220AFCH
2222
——
——
* Built to order. .
Switching NeutralsBreaker Type
Ampere Rating
Catalog Number
Maximum Interrupting Rating (kA)120V AC 120/240V AC 240V AC
BG 2-Wire Common Trip
1520 30
BG215* BG220* BG230*
1010 10
— — —
— — —
BG 3-Wire Common Trip
1520 30
BG315* BG320* BG330*
— — —
10 10 10
— — —
AFCI – Branch Feeder Type Arc Fault Circuit Interrupter
Breaker Type
Ampere Rating
Catalog Number
Interrupting Ratings (kA) RMS Symmetrical AmperesVolts AC120 120/240 240
BAF2 1-pole
15 BA115AF 10 — —20 BA120AF 10 — —
BAF2H 1-pole
15 BA115AFH 22 — —20 BA120AFH 22 — —
HBAF2 1-pole
15 BA115AFHH 65 — —20 BA120AFHH 65 — —
Original P1 Catalog Number
Revised P1 Catalog Number Description
Ratings240V 480V
MBKED3100 MBKED3100A Kit w/3-pole ED4 100A breaker 65KA 18KAMBKED3125 MBKED3125A Kit w/3-pole ED4 125A breaker 65KA 18KAMBKQJ1125 MBKQJ1125A Kit w/2-pole QJ2 125A breaker 10KA —MBKQJ1150 MBKQJ1150A Kit w/2-pole QJ2 150A breaker 10KA —MBKQJ1175 MBKQJ1175A Kit w/2-pole QJ2 175A breaker 10KA —MBKQJ1200 MBKQJ1200A Kit w/2-pole QJ2 200A breaker 10KA —MBKQJ1225 MBKQJ1225A Kit w/2-pole QJ2 225A breaker 10KA —MBKQJ3125 MBKQJ3125A Kit w/3-pole QJ2 125A breaker 10KA —MBKQJ3150 MBKQJ3150A Kit w/3-pole QJ2 150A breaker 10KA —MBKQJ3175 MBKQJ3175A Kit w/3-pole QJ2 175A breaker 10KA —MBKQJ3200 MBKQJ3200A Kit w/3-pole QJ2 200A breaker 10KA —MBKQJ3225 MBKQJ3225A Kit w/3-pole QJ2 225A breaker 10KA —MBKQJ1125H MBKQJ1125HA Kit w/2-pole QJ2H 125A breaker 42KA —MBKQJ1150H MBKQJ1150HA Kit w/2-pole QJ2H 150A breaker 42KA —MBKQJ1175H MBKQJ1175HA Kit w/2-pole QJ2H 175A breaker 42KA —MBKQJ1200H MBKQJ1200HA Kit w/2-pole QJ2H 200A breaker 42KA —MBKQJ1225H MBKQJ1225HA Kit w/2-pole QJ2H 225A breaker 42KA —MBKQJ3125H MBKQJ3125HA Kit w/3-pole QJ2H 125A breaker 42KA —MBKQJ3150H MBKQJ3150HA Kit w/3-pole QJ2H 150A breaker 42KA —MBKQJ3175H MBKQJ3175HA Kit w/3-pole QJ2H 175A breaker 42KA —MBKQJ3200H MBKQJ3200HA Kit w/3-pole QJ2H 200A breaker 42KA —MBKQJ3225H MBKQJ3225HA Kit w/3-pole QJ2H 225A breaker 42KA —MBKFD3150 MBKFD3150A Kit w/3-pole FXD6 150A breaker 65KA 35KAMBKFD3175 MBKFD3175A Kit w/3-pole FXD6 175A breaker 65KA 35KAMBKFD3200 MBKFD3200A Kit w/3-pole FXD6 200A breaker 65KA 35KAMBKFD3225 MBKFD3225A Kit w/3-pole FXD6 225A breaker 65KA 35KAMBKFD3250 MBKFD3250A Kit w/3-pole FXD6 250A breaker 65KA 35KAMBKJD1300 MBKJD1300A Kit w/2-pole JXD6 300A breaker 65KA 35KAMBKJD3300 MBKJD3300A Kit w/3-pole JXD6 300A breaker 65KA 35KAMBKJD1400 MBKJD1400A Kit w/2-pole JXD6 400A breaker 65KA 35KAMBKJD3400 MBKJD3400A Kit w/3-pole JXD6 400A breaker 65KA 35KAMBKJD12300 MBKJD12300A Kit w/2-pole JXD2 300A breaker 65KA –MBKJD32300 MBKJD32300A Kit w/3-pole JXD2 300A breaker 65KA –MBKJD12400 MBKJD12400A Kit w/2-pole JXD2 400A breaker 65KA –MBKJD32400 MBKJD32400A Kit w/3-pole JXD2 400A breaker 65KA –
NOTE: "Revised P1" Kits above only work for interior numbers ending in "T" or "N". Use "Original P1" kits for all others. Kits are for Main only. New “Revised P1” kits can be used for either top feed or bottom feed.
Dual Function AFCI/GFCI Circuit Breaker
Breaker Type
Ampere Rating
Catalog Number
Interrupting Ratings (kA) RMS Symmetrical AmperesVolts AC120 120/240 240
BFGA2 1-pole
15 BA115DF 10 — —20 BA120DF 10 — —
BFGAH2 1-pole
15 BA115DFH 22 — —20 BA120DFH 22 — —
HBFGA2 1-pole
15 BA115DFHH 65 — —20 BA120DFHH 65 — —
300A Main installed.These Revised P1 kits can now
be used as top or bottom feed.
Warehouse Stock/UnassembledMain Breaker Mounting Kits with Breakers for P1 Panels (250A and lower can be used as subfeed kits also)
www.sydist.com/SiemensMurray 1110 www.sydist.comProduct Category UPB
Selection Guide1. Select breaker type.2. Select required amperage.3. Select number of poles.4. Select branch breaker catalog
numbers.5. Select ground bar and filler
plates. (See replacement parts & accessories on Page 15.)
Branch Breakers Selection for P1
AFCI – Combination Type Arc Fault Circuit Interrupter
Breaker Type
Ampere Rating
Catalog Number
Interrupting Ratings (kA) RMS Symmetrical AmperesVolts AC120 120/240 240
BAF2 1-pole
15 B115AFC 10 — —20 B120AFC 10 — —
BAFH2 1-pole
15 B115AFCH 22 — —20 B120AFCH 22 — —
HBAF2 1-pole
15 BA115AFCHH 65 — —20 BA120AFCHH 65 — —
BAF2-pole
1520
B215AFCB220AFC
1010
——
——
BAFH2-pole
1520
B215AFCHB220AFCH
2222
——
——
* Built to order. .
Switching NeutralsBreaker Type
Ampere Rating
Catalog Number
Maximum Interrupting Rating (kA)120V AC 120/240V AC 240V AC
BG 2-Wire Common Trip
1520 30
BG215* BG220* BG230*
1010 10
— — —
— — —
BG 3-Wire Common Trip
1520 30
BG315* BG320* BG330*
— — —
10 10 10
— — —
AFCI – Branch Feeder Type Arc Fault Circuit Interrupter
Breaker Type
Ampere Rating
Catalog Number
Interrupting Ratings (kA) RMS Symmetrical AmperesVolts AC120 120/240 240
BAF2 1-pole
15 BA115AF 10 — —20 BA120AF 10 — —
BAF2H 1-pole
15 BA115AFH 22 — —20 BA120AFH 22 — —
HBAF2 1-pole
15 BA115AFHH 65 — —20 BA120AFHH 65 — —
Original P1 Catalog Number
Revised P1 Catalog Number Description
Ratings240V 480V
MBKED3100 MBKED3100A Kit w/3-pole ED4 100A breaker 65KA 18KAMBKED3125 MBKED3125A Kit w/3-pole ED4 125A breaker 65KA 18KAMBKQJ1125 MBKQJ1125A Kit w/2-pole QJ2 125A breaker 10KA —MBKQJ1150 MBKQJ1150A Kit w/2-pole QJ2 150A breaker 10KA —MBKQJ1175 MBKQJ1175A Kit w/2-pole QJ2 175A breaker 10KA —MBKQJ1200 MBKQJ1200A Kit w/2-pole QJ2 200A breaker 10KA —MBKQJ1225 MBKQJ1225A Kit w/2-pole QJ2 225A breaker 10KA —MBKQJ3125 MBKQJ3125A Kit w/3-pole QJ2 125A breaker 10KA —MBKQJ3150 MBKQJ3150A Kit w/3-pole QJ2 150A breaker 10KA —MBKQJ3175 MBKQJ3175A Kit w/3-pole QJ2 175A breaker 10KA —MBKQJ3200 MBKQJ3200A Kit w/3-pole QJ2 200A breaker 10KA —MBKQJ3225 MBKQJ3225A Kit w/3-pole QJ2 225A breaker 10KA —MBKQJ1125H MBKQJ1125HA Kit w/2-pole QJ2H 125A breaker 42KA —MBKQJ1150H MBKQJ1150HA Kit w/2-pole QJ2H 150A breaker 42KA —MBKQJ1175H MBKQJ1175HA Kit w/2-pole QJ2H 175A breaker 42KA —MBKQJ1200H MBKQJ1200HA Kit w/2-pole QJ2H 200A breaker 42KA —MBKQJ1225H MBKQJ1225HA Kit w/2-pole QJ2H 225A breaker 42KA —MBKQJ3125H MBKQJ3125HA Kit w/3-pole QJ2H 125A breaker 42KA —MBKQJ3150H MBKQJ3150HA Kit w/3-pole QJ2H 150A breaker 42KA —MBKQJ3175H MBKQJ3175HA Kit w/3-pole QJ2H 175A breaker 42KA —MBKQJ3200H MBKQJ3200HA Kit w/3-pole QJ2H 200A breaker 42KA —MBKQJ3225H MBKQJ3225HA Kit w/3-pole QJ2H 225A breaker 42KA —MBKFD3150 MBKFD3150A Kit w/3-pole FXD6 150A breaker 65KA 35KAMBKFD3175 MBKFD3175A Kit w/3-pole FXD6 175A breaker 65KA 35KAMBKFD3200 MBKFD3200A Kit w/3-pole FXD6 200A breaker 65KA 35KAMBKFD3225 MBKFD3225A Kit w/3-pole FXD6 225A breaker 65KA 35KAMBKFD3250 MBKFD3250A Kit w/3-pole FXD6 250A breaker 65KA 35KAMBKJD1300 MBKJD1300A Kit w/2-pole JXD6 300A breaker 65KA 35KAMBKJD3300 MBKJD3300A Kit w/3-pole JXD6 300A breaker 65KA 35KAMBKJD1400 MBKJD1400A Kit w/2-pole JXD6 400A breaker 65KA 35KAMBKJD3400 MBKJD3400A Kit w/3-pole JXD6 400A breaker 65KA 35KAMBKJD12300 MBKJD12300A Kit w/2-pole JXD2 300A breaker 65KA –MBKJD32300 MBKJD32300A Kit w/3-pole JXD2 300A breaker 65KA –MBKJD12400 MBKJD12400A Kit w/2-pole JXD2 400A breaker 65KA –MBKJD32400 MBKJD32400A Kit w/3-pole JXD2 400A breaker 65KA –
NOTE: "Revised P1" Kits above only work for interior numbers ending in "T" or "N". Use "Original P1" kits for all others. Kits are for Main only. New “Revised P1” kits can be used for either top feed or bottom feed.
Dual Function AFCI/GFCI Circuit Breaker
Breaker Type
Ampere Rating
Catalog Number
Interrupting Ratings (kA) RMS Symmetrical AmperesVolts AC120 120/240 240
BFGA2 1-pole
15 BA115DF 10 — —20 BA120DF 10 — —
BFGAH2 1-pole
15 BA115DFH 22 — —20 BA120DFH 22 — —
HBFGA2 1-pole
15 BA115DFHH 65 — —20 BA120DFHH 65 — —
300A Main installed.These Revised P1 kits can now
be used as top or bottom feed.
Warehouse Stock/UnassembledMain Breaker Mounting Kits with Breakers for P1 Panels (250A and lower can be used as subfeed kits also)
11www.sydist.com
Selection Guide 1. Select breaker type. 2. Select required amperage.
Branch Breakers Selection for P1
n Built to order. Allow 2–3 weeks for delivery. HACR rated.
To add shunt trip to BL breakers, see Speedfax for Breaker Accessories. To add shunt trip to BQD breakers, see Speedfax for Breaker Accessories.
3. Select number of poles. 4. Select branch breaker catalog numbers.
5. Select ground bar and filler plates. (See replacement parts & accessories on Pages 17 and 18.)
BL Branch Breakers – 10,000A IR
Amp Rating
1-Pole 120/240V
2-Pole 120/240V
2-Pole 240V
3-Pole 240V
15 20 25 30 35 40 45 50 55 60 70 80 90
100
B115 B120 B125 B130 B135 B140 B145 B150 B155 B160 B170
— — —
B215 B220 B225 B230 B235 B240 B245 B250
— B260 B270 B280 B290
B2100
B215R B220R B225R B230R B235R B240R B245R B250R
— — — — — —
B315 B320 B325 B330 B335 B340 B345 B350
— B360 B370 B380 B390
B3100
HBL Branch Breakers – 65,000A IR
Amp Rating
1-Pole 120/240V
2-Pole 120/240V
3-Pole 240V
15 20 30 40 50 60 70 80 90
100
B115HH B120HH B130HH B140HH B150HH
— — — — —
B215HH B220HH B230HH B240HH B250HH B260HH B270HH B280HH B290HH
B2100HH
B315HH B320HH B330HH B340HH B350HH B360HH B370HH B380HH B390HH
B3100HH
GFCI Personnel Protection (5MA)
Breaker Type
Ampere Rating
Catalog Number
Interrupting Ratings (kA) RMS Symmetrical AmperesVolts AC120 120/240 240
BLF 1-Pole
1520 25 30
BF115 BF120 BF125 BF130
1010 10 10
— — — —
— — — —
BLF 2-Pole
1520 30 40 50 60
BF215 BF220 BF230 BF240 BF250 BF260
— — — — — —
10 10 10 10 10 10
— — — — — —
BLHF 1-Pole
1520 30
BF115H BF120H BF130H
22 22 22
— — —
— — —
BLHF 2-Pole
15 20 30 40 50 60
BF215H BF220H BF230H BF240H BF250H BF260H
— — — — — —
22 22 22 22 22 22
— — — — — —
BLH Branch Breakers – 22,000A IR
Amp Rating
1-Pole 120/240V
2-Pole 120/240V
3-Pole 240V
15 20 25 30 40 50 55 60 70 80 90
100
B115H B120H B125H B130H B140H B150H B155H B160H B170H
— — —
B215H B220H B225H B230H B240H B250H
— B260H B270H B280H B290H
B2100H
B315H B320H B325H B330H B340H B350H
— B360H B370H B380H B390H
B3100H
BQD Branch Breakers – 14,000A IR Max. @ 480/277 Vac / 65,000A IR max. @ 240 Vac
Amp Rating
1-Pole 277V
2-Pole 480Y/277V
3-Pole 480Y/277V
15 20 25 30 35 40 45 50 60 70 80 90
100
BQD115 BQD120 BQD125 BQD130 BQD135 BQD140 BQD145 BQD150 BQD160 BQD170 BQD180 BQD190
BQD1100
BQD215 BQD220 BQD225 BQD230 BQD235 BQD240 BQD245 BQD250 BQD260 BQD270 BQD280 BQD290
BQD2100
BQD315 BQD320 BQD325 BQD330 BQD335 BQD340 BQD345 BQD350 BQD360 BQD370 BQD380 BQD390
BQD3100
GB Family Branch BreakersNGB – 25,000 A IR Max. @ 480/277V AC / 100,000 A IR @ 240V AC
HGB – 35,000 A IR Max. @ 480/277V AC / 100,000 A IR @ 240V ACLGB – 65,000 A IR Max. @ 480/277V AC / 100,000 A IR @ 240V AC
Amp Rating
1-pole 277V
2-pole 480Y/277V
3-pole 480Y/277V
15 xGB1B015B xGB2B015B xGB3B015B20 xGB1B020B xGB2B020B xGB3B020B25 xGB1B025B xGB2B025B xGB3B025B30 xGB1B030B xGB2B030B xGB3B030B35 xGB1B035B xGB2B035B xGB3B035B40 xGB1B040B xGB2B040B xGB3B040B45 xGB1B045B xGB2B045B xGB3B045B50 xGB1B050B xGB2B050B xGB3B050B60 xGB1B060B xGB2B060B xGB3B060B70 xGB1B070B xGB2B070B xGB3B070B80 xGB1B080B xGB2B080B xGB3B080B90 xGB1B090B xGB2B090B xGB3B090B100 xGB1B100B xGB2B100B xGB3B100B110 xGB1B110B xGB2B110B xGB3B110B125 xGB1B125B xGB2B125B xGB3B125B
Replace x with N, H or L depending on desired type of breakerNOTE: 2-pole and 3-pole xGB Frame Breakers are also rated at 14,000 A IR max. for 600Y/347V AC systems. UPB interiors are only rated to 480V max. - see factory assembled section for proper interiors.
Warehouse Stock / UnassembledType P1 Panelboards
12 www.sydist.com/SiemensMurray 12 www.sydist.com
www.usa.siemens.com/loadcenters
Siemens Single-Phase Load Centers Features and Comparison
Features ES Series Murray PL SeriesBussing AL AL CU
Convertible MB to MLO Only MB to MLO/MLO to MB MB to MLO/MLO to MB
Invertible (Indoor) Yes Yes Yes
Insta-Wire Neutrals Yes No Yes
Outboard Neutrals No Yes No
High-Circuitry Yes Yes Yes
Trim Mount Tabs Yes Yes Yes
Packaging Single-Carton Carton-in-Carton Carton-in-Carton
Breakers Siemens Siemens or Murray Siemens
www.sydist.com/SiemensMurray 1312 www.sydist.com
www.usa.siemens.com/loadcenters
Siemens Single-Phase Load Centers Features and Comparison
Features ES Series Murray PL SeriesBussing AL AL CU
Convertible MB to MLO Only MB to MLO/MLO to MB MB to MLO/MLO to MB
Invertible (Indoor) Yes Yes Yes
Insta-Wire Neutrals Yes No Yes
Outboard Neutrals No Yes No
High-Circuitry Yes Yes Yes
Trim Mount Tabs Yes Yes Yes
Packaging Single-Carton Carton-in-Carton Carton-in-Carton
Breakers Siemens Siemens or Murray Siemens
13www.sydist.com
www.usa.siemens.com/loadcenters
The patented INSTA-WIRE™ neutral/ground system allows for faster installation because screws are backed out, ready for wire insertion. The
visible neutral and grounds system aids in the insertion of conductors.
The pre-positioned bond screw eliminates bond strap/screw assemblies, and reduces the risk of losing components in the field.
Mounting tabs on the trim hold it in place on the load center, freeing up both hands to drive the trim screws.
The outdoor enclosure has a slide hinge door for the easiest installation and can be removed by backing out only one screw.
PL Series Load Centers ship with trims packaged separately.
All devices convertible from main lug to main breaker and vice versa.
Invertible for bottom feed application.
Copper bus
All devices are provided with 2 factory installed
ground bars.
Combination head screw on the neutrals, ground, trim, upper pan, and bond screw
provide installation flexibility.
A rigid, sturdy base pan provides the
ruggedness required for the most harsh
applications.
Siemens PL Series Load Centers™
Features and Benefits
Siemens Single-Phase Load Centers Features and Comparison
14 www.sydist.com/SiemensMurray 14 www.sydist.com
PL™ Series Load Centers1-Phase Main Lug and Main Breaker Load Centers1-Phase, 3-Wire SN, 120/240 Volts Ac
Main Breaker/Convertible Load Centers
Copper Busg
12-70 Circuits / 100-225 Amperes 60/75°C Rated 22,000A IR
Branch Circuits Indoor Enclosure – Nema Type 1 Outdoor Enclosure – Nema Type 3R
Amp RatingNo. Of Spaces
No. Of Circuits Catalog Number
Enclosure Height (Inches) Catalog Number
Enclosure Height (Inches)
100 12 24 P1224B1100CU 18 PW1224B1100CU 21100 16 24 P1624B1100CU 21 PW1624B1100CU 23100 20 20 P2020B1100CU 24 PW2020B1100CU 27100 20 24 P2024B1100CU 24 — —100 24 24 P2424B1100CU 24 — —100 30 30 P3030B1100CU 30 — —100 30 40 — — PW3040B1100CU 35125 30 30 P3030B1125CU 30 PW3040B1125CU 35150 20 30 P2030B1150CU 24 — —150 20 30 — — PW2030B1150CU 27150 30 30 P3030B1150CU 30 — —
150 30 40 — — PW3040B1150CU 35200 20 40 P2040B1200CU 30 PW2040B1200CU 27200 30 40 P3040B1200CU 36 PW3040B1200CU 35200 30 40 P3040B1200 36 — —200 40 40 P4040B1200CU 36 PW4040B1200CU 38200 40 40 P4040B1200 36 — —200 54 70 P5470B1200CU 44 — —225 42 60 P4260B1225CU 39 PW4260B1225CU 42225 54 70 P5470B1225CU 44 — —
Single phase factory installed 22kA IR main circuit breaker offers 22/10kA IR series combination rating when using 10kA type QP, QT, QPF, QE, QN, and QAF/QAFC branch breakers.
Main Lug/Convertible Load Centers
Copper Busg
12-70 Circuits / 125-225 Amperes 60/75° Rated 100,000A IR
Branch Crcuits Indoor Enclosure - Nema Type 1 Outdoor Enclosure - Nema Type 3R
Amp RatingNo. Of Spaces
No. Of Circuits Catalog Number
Enclosure Height (Inches) Catalog Number
Enclosure Height (Inches)
125 12 12 P1212L1125CU 18 PW1212L1125CU 21125 12 24 P1224L1125CU 18 PW1224L1125CU 21125 16 24 P1624L1125CU 21 PW1624L1125CU 23125 20 20 P2020L1125CU 24 — —125 20 24 P2024L1125CU 24 — —125 24 40 P2440L1125CU 24 — —125 30 40 P3040L1125CU 30 PW3040L1125CU 35125 40 40 P4040L1125CU 36 — —150 20 30 P2030L1150CU 24 PW2030L1150CU 27200 12 24 P1224L1200CU 24 PW1224L1200CU 23200 20 40 P2040L1200CU 30 PW2040L1200CU 27200 24 40 P2440L1200CU 30 — —200 30 30 P3030L1200CU 36 — —200 30 40 P3040L1200CU 36 PW3040L1200CU 35200 30 40 P3040L1200 36 — —200 30 54 P3054L1200CU 36 PW3054L1200CU 35200 40 40 P4040L1200CU 36 PW4040L1200CU 38200 40 40 P4040L1200 36 — —225 12 24 — — PW1224L1225CU 23225 42 60 P4260L1225CU 39 PW4260L1225CU 42225 54 70 P5470L1225CU 44 — —
Suitable for use as service equipment. May be installed on higher rated systems when protected
by a circuit breaker with a higher AIR rating. Indoor enclosures are 14 1/4" wide by 3 7/8" deep. Outdoor enclosures are 14 1/2" wide by 4 1/4" deep. Suitable for use as service entrance equipment when not
more than six main disconnecting means are provided. See article 230.71 of the NEC®.
125A load centers will accept MBK100A and MBK125A. 150A load centers will accept MBK150A. 200A load centers will accept MBK200A and MBK150A. 225A load centers will accept MBK225A, MBK200A, MBK150A.
g Copper bus load centers are recommended for those appli-cations where the environment may be severe (i.e. far and coastal areas).
Includes all PL Series features with aluminum bussing.
ES and PL Series Load Center Video
Load Center Mobile Webpage
Offering a full line of load centers, Siemens meets the needs of every application and all of your installation needs. From small load centers, riser panels and three phase load centers, to the PL and ES Series Load Centers™, Siemens has the highest quality, most complete offering on the market. Focusing on reliability, value and labor savings - Siemens is committed to increase productivity by reducing installation times.
www.sydist.com/SiemensMurray 1515www.sydist.com
PL™ Series Load Centers1-Phase Special Load Centers1-Phase, 3-Wire SN, 120/240 Volts AC
Includes all PL Series features with aluminum bussing.
Indoor enclosures are 14 1/4" wide by 3 7/8" deep. May be installed on higher rated systems when protected
by a circuit breaker with a higher AIR rating. Outdoor enclosures are 14 1/2" wide by 4 1/4" deep. Main lug panel rated 100,000A IR. Load centers with white trim have increased lead time of
3-4 weeks. Sold in pallet quantites only.g Load centers with CUW suffix indicates copper bus with
white trim. Load centers with W suffix only indicates aluminum bus with white trim.
Split Ground Series Main Lug Convertible Load Centers Copper Bus12-60 Circuits / 125-200 Amperes 60/75° Rated, 100,000A IRBranch Circuits Indoor Enclosure – Nema Type 1
Amp Rating
No. Of Spaces
No. Of Circuits Catalog Number
Enclosure Height (Inches)
125 12 24 P1224L1125CUSG 18125 16 24 P1624L1125CUSG 21125 20 30 P2030L1125CUSG 24125 24 30 P2430L1125CUSG 24150 20 30 P2030L1150CUSG 24200 30 40 P3040L1200CUSG 36200 30 40 P3040L1200SG 36200 40 40 P4040L1200CUSG 36200 40 40 P4040L1200SG 36225 40 60 P4260L1225CUSG 39
Split Ground Series Main Breaker Convertible Load Centers Copper Bus40 Circuits / 200 Amperes 60/75° Rated, 22,000A IR
Branch Circuits Indoor Enclosure – Nema Type 1
Amp Rating
No. Of Spaces
No. Of Circuits Catalog Number
Enclosure Height (Inches)
200 40 40 P4040B1200CUSG 36
Outdoor Trailer Panels Copper Bus16 Circuits / 200 Amperes 60/75° Rated, 22,000A IR
Amp Rating
No. Of Spaces
No. Of Circuits Catalog Number Main Breaker
Enclosure Height (Inches)
200 8 16 PW0816L1200TCMBK150A or MBK200A
Field Installed 23
200 8 16 PW0816B1200TC MBK200A Factory Installed 23
Split Ground Load Centers have factory installed 100% neutral with factory bonded
75% ground. No neutral tie strap.
Load Centers with White Trim
Copper or Aluminum Busg
40 Circuits / 200 Amperes 60/75° Rated 22,000A IR
Branch Circuits Indoor Enclosure - Nema Type 1
Amp RatingMain Lug / Main Breaker No. Of Spaces No. Of Circuits Catalog Number
Enclosure Height (Inches)
200 Main Breaker 30 40 P3040B1200W 36200 Main Breaker 40 40 P4040B1200W 36200 Main Breaker 40 40 P4040B1200CUW 36
ES and PL Series Load Center Video
Load Center Mobile Webpage
Offering a full line of load centers, Siemens meets the needs of every application and all of your installation needs. From small load centers, riser panels and three phase load centers, to the PL and ES Series Load Centers™, Siemens has the highest quality, most complete offering on the market. Focusing on reliability, value and labor savings - Siemens is committed to increase productivity by reducing installation times.
16 www.sydist.com/SiemensMurray 16 www.sydist.com
PL™ Series Load Centers3-Phase Main Lug and Main Breaker Load Centers3-Phase, 3-Wire, 240 Volt AC or 3-Phase, 4-Wire, 120/240 or 120/208 Volts AC
Main Breaker/Convertible Load Centers Copper Bus
30-70 Circuits / 100-225 Amperes 60/75°C Rated 22,000A IR
Branch Circuits Indoor Enclosure – Nema Type 1 Outdoor Enclosure – Nema Type 3R
Amp Rating
No. Of Spaces
No. Of Circuits Catalog Number
Enclosure Height (Inches) Catalog Number
Enclosure Height (Inches)
100 12 24 P1224B3100CU 24 — —100 30 42 P3042B3100CU 30 — —125 30 30 P3030B3125CU 39 — —150 24 42 P2442B3150CU 36 — —150 42 42 P4242B3150CU 42 — —200 30 54 P3054B3200CU 39 PW3054B3200CU 38200 42 60 P4260B3200CU 42 PW4260B3200CU 42225 42 60 P4260B3225CU 42 — —225 42 60 P4260B3225TCU 49 — —225 54 70 P5470B3225CU 49 — —
Main Lug/Convertible Load Centers
Copper Bus
12-70 Circuits / 125-225 Amperes 60/75° Rated 100,000A IR
Branch Circuits Indoor Enclosure – Nema Type 1 Outdoor Enclosure – Nema Type 3R
Amp Rating
No. Of Spaces
No. Of Circuits Catalog Number
Enclosure Height (Inches) Catalog Number
Enclosure Height (Inches)
125 12 24 P1224L3125CU g 21 PW1224L3125CU g 21200 24 42 P2442L3200CU 36 PW2442L3200CU 35200 30 54 P3054L3200CU 39 PW3054L3200CU 38225 42 60 P4260L3225CU 42 PW4260L3225CU 42225 54 70 P5470L3225CU 49 — —
May be installed on higher rated systems when protected by a circuit breaker with a higher AIR rating.
Back fed main breaker. Indoor enclosures are 14 1/4" wide by 3 7/8" deep. Outdoor enclosures are 14 1/2" wide by 4 1/4" deep. Suitable for use as service entrance equipment when not
more than six main disconnecting means are provided. See article 230.71 of the NEC®.
Includes factory installed feed through lugs and is also non-convertible.
g Non-convertible to main breaker. All load centers are provided with tin plated copper bus
bars. Rated 100,000A IR in series with breakers listed on
wiring diagram. All load centers are provided with tin-plated copper
bus bars.
ES and PL Series Load Center Video
Load Center Mobile Webpage
Offering a full line of load centers, Siemens meets the needs of every application and all of your installation needs. From small load centers, riser panels and three phase load centers, to the PL and ES Series Load Centers™, Siemens has the highest quality, most complete offering on the market. Focusing on reliability, value and labor savings - Siemens is committed to increase productivity by reducing installation times.
www.sydist.com/SiemensMurray 1717www.sydist.com
1
5
7 8
9
The Murray Rock Solid Load Center is the highest quality, most versatile design in the industry. Features on the Rock Solid Load Center include:
1. "Swiss Cheese" style neutral bars provide multiple 1/0 connection points.
2. All units include factory installed ground bar and isolated neutral.
3. With the use of the included bonding strap, ground bars and neutral bars can be bonded for service entrance applications.
4. Outboard neutral and groundbars allow for all neutral and ground connections to be located away from breaker connections, making for a neat, clean installation.
5. Mounting tabs on the trim hold it in place on the load center, freeing up both hands to drive the trim screws.
6. Combination head screw on trim and upper pan screws provide installation flexibility.
7. All devices are convertible from main lug to main breaker or vice versa with the addition of main breaker or main lug kits.
8. All main breakers are straight in wired – no back feeding required.
9. A rigid, sturdy base pan with metal hook rails provides the most rugged breaker connection in the industry.
10. The outdoor enclosure has a slide hinge door for the easiest of installation and can be removed by backing out only one screw.
11. All indoor Rock Solid Load Centers are invertible for bottom feed applications.
The following offering is available in the Murray line:
12-60 Circuits/Spaces
Indoor and outdoor enclosures
100 to 225 Amp
Main lug and main breaker
Value packs - a mix of branch breakers provided with the
load center
3
24
11
10
Rock Solid Load CentersFeatures
18 www.sydist.com/SiemensMurray 18 www.sydist.com
Convertible to main breaker by using the following main breaker kits: 100A load centers: MBK100M only. 125A load centers: MBK100M and MBK125M only. 150A load centers: MBK150M only. 200A load centers: MBK150M and MBK200M only. 225A load centers: MBK150M, MBK200M, and MBK225M only.
100-225A only. Standard package quantity equal to 1.
Dimensions shown are representative of outside box length, width & depth (± 1⁄8”) and do not include allowance for mounting bumps, endwalls, hubs or hardware protrusions. Allow approximately 11⁄4” additional in length and width dimensions for surface or combination overhang. Consult factory for specific details if required.
Hub provision only. Closure plate included. Panels through 225A require HS type hub; panels over 225A require HV type hub. See accessories page <?> for hub selection.
Copper bus load centers are recommended for those
applications where the environment may be severe (ie farm and coastal areas).
Rock Solid Load Centers
Main Lug Only, 1Ø, 65,000 AIC, Main Lug Panels 3-Wire 120/240V AC or 208Y/120V AC, Insulated and Bonded Split Neutrals
Load centers on this page through 225 amp feature a split neutral insulated bars. For service entrance applications, install bonding strap, and use both bars for neutral and ground conductors. For non service entrance applications, do not install bonding strap and use insulated bars for neutral conductors and bonded bar for ground conductors.
12-42 Circuit, 125–225 Amperes
AmpsMax.
No. ofSpaces
Max.Circuit
Indoor Type 1 Dimensions Outdoor Type 3R Dimensions
Catalog Number Height Width Depth Catalog Number Height Width Depth
125 12 24 LC1224L1125 21 143⁄8 4 LW1224L1125 20 141⁄4 41⁄2125 16 32 LC1632L1125 21 143⁄8 4 LW1632L1125 29 141⁄4 41⁄2
125 20 40 LC2040L1125 24 143⁄8 4 LW2040L1125 29 141⁄4 41⁄2125 30 40 LC3040L1125 30 143⁄8 4 — — — —150 16 32 LC1632L1150 24 143⁄8 4 — — — —150 24 40 LC2440L1150 30 143⁄8 4 — — — —200 12 24 — — — — LW1224L1200 29 141⁄4 41⁄2200 20 40 LC2040L1200 30 143⁄8 4 LW2040L1200 29 141⁄4 41⁄2200 24 40 LC2440L1200 30 143⁄8 4 — — — —200 30 40 LC3040L1200 36 143⁄8 4 LW3040L1200 38 141⁄4 41⁄2200 40 40 LC4040L1200 39 143⁄8 4 — — — —225 40 60 LC4060L1225 39 143⁄8 4 — — — —
Copper Bus
AmpsMax.
No. ofSpaces
Max.Circuit
Indoor Type 1 Dimensions Outdoor Type 3R Dimensions
Catalog Number Height Width Depth Catalog Number Height Width Depth
125 20 40 LC2040L1125CU 24 143⁄8 4 — — — —200 20 40 LC2040L1200CU 30 143⁄8 4 — — — —200 30 40 LC3040L1200CU 36 143⁄8 4 — — — —200 40 40 LC4040L1200CU 39 143⁄8 4 — — — —225 12 24 — — — — LW1224L1225CU 29 141⁄4 41⁄2225 42 42 LC4242L1225CU 42 143⁄8 4 LW4242L1225CU 42 141⁄4 41⁄2
LW2040L1200
www.sydist.com/SiemensMurray 1918 www.sydist.com
Convertible to main breaker by using the following main breaker kits: 100A load centers: MBK100M only. 125A load centers: MBK100M and MBK125M only. 150A load centers: MBK150M only. 200A load centers: MBK150M and MBK200M only. 225A load centers: MBK150M, MBK200M, and MBK225M only.
100-225A only. Standard package quantity equal to 1.
Dimensions shown are representative of outside box length, width & depth (± 1⁄8”) and do not include allowance for mounting bumps, endwalls, hubs or hardware protrusions. Allow approximately 11⁄4” additional in length and width dimensions for surface or combination overhang. Consult factory for specific details if required.
Hub provision only. Closure plate included. Panels through 225A require HS type hub; panels over 225A require HV type hub. See accessories page <?> for hub selection.
Copper bus load centers are recommended for those
applications where the environment may be severe (ie farm and coastal areas).
Rock Solid Load Centers
Main Lug Only, 1Ø, 65,000 AIC, Main Lug Panels 3-Wire 120/240V AC or 208Y/120V AC, Insulated and Bonded Split Neutrals
Load centers on this page through 225 amp feature a split neutral insulated bars. For service entrance applications, install bonding strap, and use both bars for neutral and ground conductors. For non service entrance applications, do not install bonding strap and use insulated bars for neutral conductors and bonded bar for ground conductors.
12-42 Circuit, 125–225 Amperes
AmpsMax.
No. ofSpaces
Max.Circuit
Indoor Type 1 Dimensions Outdoor Type 3R Dimensions
Catalog Number Height Width Depth Catalog Number Height Width Depth
125 12 24 LC1224L1125 21 143⁄8 4 LW1224L1125 20 141⁄4 41⁄2125 16 32 LC1632L1125 21 143⁄8 4 LW1632L1125 29 141⁄4 41⁄2
125 20 40 LC2040L1125 24 143⁄8 4 LW2040L1125 29 141⁄4 41⁄2125 30 40 LC3040L1125 30 143⁄8 4 — — — —150 16 32 LC1632L1150 24 143⁄8 4 — — — —150 24 40 LC2440L1150 30 143⁄8 4 — — — —200 12 24 — — — — LW1224L1200 29 141⁄4 41⁄2200 20 40 LC2040L1200 30 143⁄8 4 LW2040L1200 29 141⁄4 41⁄2200 24 40 LC2440L1200 30 143⁄8 4 — — — —200 30 40 LC3040L1200 36 143⁄8 4 LW3040L1200 38 141⁄4 41⁄2200 40 40 LC4040L1200 39 143⁄8 4 — — — —225 40 60 LC4060L1225 39 143⁄8 4 — — — —
Copper Bus
AmpsMax.
No. ofSpaces
Max.Circuit
Indoor Type 1 Dimensions Outdoor Type 3R Dimensions
Catalog Number Height Width Depth Catalog Number Height Width Depth
125 20 40 LC2040L1125CU 24 143⁄8 4 — — — —200 20 40 LC2040L1200CU 30 143⁄8 4 — — — —200 30 40 LC3040L1200CU 36 143⁄8 4 — — — —200 40 40 LC4040L1200CU 39 143⁄8 4 — — — —225 12 24 — — — — LW1224L1225CU 29 141⁄4 41⁄2225 42 42 LC4242L1225CU 42 143⁄8 4 LW4242L1225CU 42 141⁄4 41⁄2
LW2040L1200
19www.sydist.com
100-225A only. This information is based on use of 10,000 AIC rated branch
circuit breakers in load center (MP-T, MH-T, MP-GT, MG). Most series ratings exclude MH-T above 40 Amp. Consult device wiring diagram for specific data.
Remote Only Types MQH & MQL may be mounted internal in 150-225
amp 3Ø main breaker load centers.
Dimensions shown are representative of outside box length, width & depth (±1⁄8”) and do not include allowance for mounting bumps, endwalls, hubs or hardware protrusions. Allow approximately 11⁄4” additional in length and width dimensions for surface or combination overhang. Consult factory for specific details if required.
Hub provision only. Closure plate included. Panels through 225A require HS type hub; panels over 225A require HV type hub.
g Standard package quantity equal to 1. Copper bus load centers are recommended for those
applications where the environment may be severe (ie farm and coastal areas).
Rock Solid Load CentersMain Breaker, 1Ø, 22,000 AIC
Load Center Short Circuit Current Rating
Copper Bus
AmpsMax.
No. ofSpaces
Max.Circuit
Indoor Type 1g
Catalog Number
Dimensions
Height Width Depth
100 20 40 LC2040B1100CU 24 143⁄8 4
200 20 40 LC2040B1200CU 30 143⁄8 4
200 30 40 LC3040B1200CU 36 143⁄8 4
200 40 40 LC4040B1200CU 39 143⁄8 4
Load Center Short Circuit Current Rating
Load Center Short CircuitCurrent Rating
Load CenterMain Rating
Internal or RemoteMain or FeederCircuit Breaker Type
10,000 AIC Any Any
22,000 AIC100/125A MP-HT, MQH
150/200/225A MD-H, MQHbd, MPP-HT
42,000 AIC100/125A MQL
150/200/225A MQL
65,000 AIC100/125A MP-MT, MPP-MT
150/200/225A MPP-MTc
100,000 AIC 100/125A 100A, 300V AC, Class “T” Fuse
100,000 AIC 150/200/225A 200A, 300V AC, Class “T” Fuse
Load centers on this page through 200 amp feature a new split neutral with one bonded and one insulated bar. For service entrance applications, install bonding strap, and use both bars for neutral and ground conductors. For non service entrance applications, do not install bonding strap and use insulated bar for neutral conductors and bonded bar for ground conductors.
12-42 Circuit, 100-200 Amperes
AmpsMax.
No. ofSpaces
Max.Circuit
Catalog Number Dimensions Outdoor Type 3Rg Dimensions
Indoor Type 1g Height Width Depth Catalog Number Height Width Depth100 12 24 LC1224B1100 18 143⁄8 4 LW1224B1100 23 141⁄4 41⁄2100 16 32 — — — — LW1632B1100 23 141⁄4 41⁄2100 20 40 LC2040B1100 24 143⁄8 4 — — — —100 24 40 LC2440B1100 24 143⁄8 4 — — — —100 30 40 LC3040B1100 30 143⁄8 4 — — — —150 16 32 LC1632B1150 24 143⁄8 4 — — — —150 20 40 LC2040B1150 30 143⁄8 4 LW2040B1150 29 141⁄4 41⁄2150 24 40 LC2440B1150 30 143⁄8 4 — — — —150 30 40 LC3040B1150 36 143⁄8 4 — — — —200 12 24 — — — — LW1224B1200 29 141⁄4 41⁄2200 16 32 LC1632B1200 30 143⁄8 4 — — — —200 20 40 LC2040B1200 30 143⁄8 4 LW2040B1200 29 141⁄4 41⁄2200 24 40 LC2440B1200 30 143⁄8 4 — — — —200 30 40 LC3040B1200 36 143⁄8 4 LW3040B1200 38 141⁄4 41⁄2200 40 40 LC4040B1200 39 143⁄8 4 LW4040B1200 38 141⁄4 41⁄2200 30 54 LC3054B1200 36 143⁄8 4 — — — —200 40 40 LC4040B1200 39 143⁄8 4 — — — —200 40 60 LC4060B1200 401⁄2 157⁄8 5 — — — —
Murray load centers have UL recognized short circuit current ratings up to 100,000 Amps, when used with appropriate main or feeder (remote or internal) overcurrent devices. Load center ratings are shown below. For load center applications with residential or commercial metering equipment, refer to the appropriate catalog section.
1Ø, main breaker load centers are Underwriter’s Laboratories Listed for use with 60/75°C conductors and accept Murray branch circuit breakers which are also UL Listed for use with 60/75°C conductors. Type 3R load centers are furnished with a hub opening closure plate.
LC2040B1200
20 www.sydist.com/SiemensMurray 20 www.sydist.com
www.usa.siemens.com/loadcenters
Siemens ES Series Load Centers™
Features and Benefits
The pre-positioned bond screw eliminates bond strap/screw assemblies, and reduces the risk of losing components in the field.
Mounting tabs on the trim hold it in place on the load center, freeing up both hands to drive the trim screws.
The outdoor enclosure has a slide hinge door for the easiest installation and can be removed by backing out only one screw.
ES Series Load Centers ship in single piece carton.
Main breaker convertible to main lug but main lug not convertible.
Invertible for bottom feed application.
Aluminum bus
Combination head screw on the neutrals, ground, trim, upper pan, and bond screw
provide installation flexibility.
A rigid, sturdy base pan
provides the ruggedness required for
the most harsh applications.
Single side inboard neutral on 24 circuits and below; dual on 30 circuits
and above.
Ground bar field installed (select skus with “G”
suffix will have ground bar factory installed).
The patented INSTA-WIRE™ neutral/ground system allows for faster installation because screws are backed out, ready for wire insertion. The visible neutral and grounds system aids in the insertion of conductors.
www.sydist.com/SiemensMurray 2121www.sydist.com
Siemens ES Series Load Centers™
Features and Benefits
ES™ Series Load Centers1-Phase Main Lug and Main Breaker Load Centers1-Phase, 3-Wire SN, 120/240 Volts AC
Main Breaker/Convertible Load Centers
Aluminum Bus12-70 circuits / 100-225 amperes 60/75°C rated 22,000A IR
Branch Circuits Indoor Enclosure – Nema Type 1 Outdoor Enclosure – Nema Type 3R
AmpRating No. Of Spaces
No. Of Circuits
Catalog Number
Enclosure Height (Inches)
Catalog Number
Enclosure Height (Inches)
100 10 20 S1020B1100 18 — —100 12 24 S1224B1100 18 SW1224B1100 21100 16 24 S1624B1100 21 SW1624B1100 23100 20 20 S2020B1100 24 SW2020B1100 27100 20 24 S2024B1100 24 — —100 30 30 S3030B1100 30 — —125 12 24 — — SW1224B1125 21125 16 24 S1624B1125 21 — —125 16 32 — — SW2024B1125 27125 24 24 S2424B1125 24 SW2424B1125 27125 30 30 S3030B1125 30 — —125 30 40 S3040B1125 30 SW3040B1125 35150 16 30 S1630B1150 24 — —150 20 30 S2030B1150 24 — —150 24 30 S2430B1150 30 — —150 30 30 S3030B1150 30 — —150 30 40 S3040B1150 30 SW3040B1150 35150 40 40 — — SW4040B1150 38200 16 32 S1632B1200 24 — —200 20 40 S2040B1200 30 SW2040B1200 27200 24 40 S2440B1200 30 — —200 30 40 S3040B1200 36 SW3040B1200 35200 40 40 S4040B1200 36 SW4040B1200 38
200 54 70 S5470B1200 44 — —225 42 60 S4260B1225 39 SW4260B1225 42225 54 70 S5470B1225 44 — —
Main Lug/Non-Convertible Load Centers Aluminum Bus12-70 circuits / 125-225 amperes 60/75° rated 100,000A IRBranch Circuits Indoor Enclosure - Nema Type 1 Outdoor Enclosure - Nema Type 3R
Amp Rating No. Of Spaces
No. Of Circuits
Catalog Number
Enclosure Height (Inches)
Catalog Number
Enclosure Height (Inches)
125 12 12 S1212L1125 18 SW1212L1125 21125 12 24 S1224L1125 18 SW1224L1125 21125 16 24 S1624L1125 21 SW1624L1125 21125 20 20 S2020L1125 21 — —125 20 20 S2020L1125G 21 — —125 20 24 S2024L1125 21 — —125 20 24 S2024L1125G 21 — —125 24 24 S2424L1125 24 SW2424L1125 27125 24 24 S2424L1125G 24 — —125 24 40 S2440L1125 24 — —125 30 40 S3040L1125 30 SW3040L1125 29125 30 40 S3040L1125G 30 — —125 40 40 S4040L1125 36 — —150 20 30 S2030L1150 24 SW2030L1150 27200 12 24 S1224L1200 21 SW1224L1200 21200 20 40 S2040L1200 24 SW2040L1200 27200 24 40 S2440L1200 30 — —200 30 30 S3030L1200 30 — —200 30 40 S3040L1200 30 SW3040L1200 35200 30 54 S3054L1200 30 SW3054L1200 35200 40 40 S4040L1200 36 SW4040L1200 35225 12 24 — — SW1224L1225 23225 42 60 S4260L1225 36 SW4260L1225 38225 54 70 S5470L1225 42 — —
Suitable for use as service equipment. May be installed on higher rated systems when protected by a circuit breaker with a higher AIR rating. Indoor enclosures are 14 1/4" wide by 3 7/8" deep. Outdoor enclosures are 14 1/2" wide by 4 1/4" deep. Suitable for use as service entrance equipment when not more than six main disconnecting means are provided. See article
230.71 of the NEC®. ES Series single phase skus with a "G" suffix have ground bar included (factory installed).
ES and PL Series Load Center Video
Load Center Mobile Webpage
Offering a full line of load centers, Siemens meets the needs of every application and all of your installation needs. From small load centers, riser panels and three phase load centers, to the PL and ES Series Load Centers™, Siemens has the highest quality, most complete offering on the market. Focusing on reliability, value and labor savings - Siemens is committed to increase productivity by reducing installation times.
Main Breaker
Main Lug
22 www.sydist.com/SiemensMurray 22 www.sydist.com
Load Centers With White Trim
Aluminum Bus16-40 circuits / 100 – 200 amperes 60/75° rated 100,000A IRBranch Circuits Indoor Enclosure – Nema Type 1
Amp Rating
Main Lug / Main Breaker
No. Of Spaces
No. Of Circuits
Catalog Number
Enclosure Height (Inches)
100 Main breaker 16 24 S1624B1100W
21
125 Main lug 20 20 S2020L1125W 21
125 Main lug 24 24 S2424L1125W 24
200 Main lug 30 30 S3030L1200W 30
125 Main lug 30 40 S3040L1125W 30
200 Main breaker 40 40 S4040B1200W
36
Outdoor Trailer Panels16 circuits / 200 amperes
Amp Rating Main BreakerNo. Of Spaces
No. Of Circuits Catalog Number
Enclosure Height (Inches)
200 N/A 8 16 SW0816L1200T 23
200 MBK200A 8 16 SW0816B1200T
23
Split Ground Series Load Centers
30-40 Circuits / 125-200 Amperes
16 circuits / 200 amperes Aluminum BusBranch Circuits Indoor Enclosure – Nema Type 1
Amp Rating
Main Lug / Main Breaker
No. Of Spaces
No. Of Circuits Catalog Number
Enclosure Height (Inches)
125 Main lug 20 30 S2030L1125SG 21
150 Main breaker 30 30 S3030B1150SG 30
200 Main breaker 40 40 S4040B1200SG 36
Load centers with white trim have increased lead time of 3-4 weeks. Sold in pallet quantities only. Additional charge will apply. Contact sales office for details. Indoor enclosures are 14 1/4" wide by 3 7/8" deep. Breakers are shipped inside a sleeve located inside the load center. Outdoor enclosures are 14 1/2" wide by 4 1/4" deep. Main breaker rated 22,000A IR. Split Ground load centers have factory installed 100% neutral with factory bonded 75% ground.
ES™ Series Load Centers1-Phase Special Load Centers1-Phase, 3-Wire SN, 120/240 Volts AC
ES and PL Series Load Center Video
Load Center Mobile Webpage
Offering a full line of load centers, Siemens meets the needs of every application and all of your installation needs. From small load centers, riser panels and three phase load centers, to the PL and ES Series Load Centers™, Siemens has the highest quality, most complete offering on the market. Focusing on reliability, value and labor savings - Siemens is committed to increase productivity by reducing installation times.
Value Pack Load Centers
Aluminum Bus
Amp RatingMain Lug / Main Breaker
No. Of Spaces
No. Of Circuits Catalog Number Breakers Included
100 Main breaker 20 20 S2020B1100P (3) Q120, (1) Q230
200 Main breaker 30 40 S3040B1200P (3) Q120, (1) Q230
200 Main lug 30 40 S3040L1200P (3) Q120, (1) Q230
200 Main breaker 40 40 S4040B1200P (3) Q120, (1) Q230
www.sydist.com/SiemensMurray 2322 www.sydist.com
Load Centers With White Trim
Aluminum Bus16-40 circuits / 100 – 200 amperes 60/75° rated 100,000A IRBranch Circuits Indoor Enclosure – Nema Type 1
Amp Rating
Main Lug / Main Breaker
No. Of Spaces
No. Of Circuits
Catalog Number
Enclosure Height (Inches)
100 Main breaker 16 24 S1624B1100W
21
125 Main lug 20 20 S2020L1125W 21
125 Main lug 24 24 S2424L1125W 24
200 Main lug 30 30 S3030L1200W 30
125 Main lug 30 40 S3040L1125W 30
200 Main breaker 40 40 S4040B1200W
36
Outdoor Trailer Panels16 circuits / 200 amperes
Amp Rating Main BreakerNo. Of Spaces
No. Of Circuits Catalog Number
Enclosure Height (Inches)
200 N/A 8 16 SW0816L1200T 23
200 MBK200A 8 16 SW0816B1200T
23
Split Ground Series Load Centers
30-40 Circuits / 125-200 Amperes
16 circuits / 200 amperes Aluminum BusBranch Circuits Indoor Enclosure – Nema Type 1
Amp Rating
Main Lug / Main Breaker
No. Of Spaces
No. Of Circuits Catalog Number
Enclosure Height (Inches)
125 Main lug 20 30 S2030L1125SG 21
150 Main breaker 30 30 S3030B1150SG 30
200 Main breaker 40 40 S4040B1200SG 36
Load centers with white trim have increased lead time of 3-4 weeks. Sold in pallet quantities only. Additional charge will apply. Contact sales office for details. Indoor enclosures are 14 1/4" wide by 3 7/8" deep. Breakers are shipped inside a sleeve located inside the load center. Outdoor enclosures are 14 1/2" wide by 4 1/4" deep. Main breaker rated 22,000A IR. Split Ground load centers have factory installed 100% neutral with factory bonded 75% ground.
ES™ Series Load Centers1-Phase Special Load Centers1-Phase, 3-Wire SN, 120/240 Volts AC
ES and PL Series Load Center Video
Load Center Mobile Webpage
Offering a full line of load centers, Siemens meets the needs of every application and all of your installation needs. From small load centers, riser panels and three phase load centers, to the PL and ES Series Load Centers™, Siemens has the highest quality, most complete offering on the market. Focusing on reliability, value and labor savings - Siemens is committed to increase productivity by reducing installation times.
Value Pack Load Centers
Aluminum Bus
Amp RatingMain Lug / Main Breaker
No. Of Spaces
No. Of Circuits Catalog Number Breakers Included
100 Main breaker 20 20 S2020B1100P (3) Q120, (1) Q230
200 Main breaker 30 40 S3040B1200P (3) Q120, (1) Q230
200 Main lug 30 40 S3040L1200P (3) Q120, (1) Q230
200 Main breaker 40 40 S4040B1200P (3) Q120, (1) Q230
23www.sydist.com
Main Breaker/Convertible Load Centers Aluminum Bus30-60 circuits / 100-225 amperes 60/75°C rated 10,000A IR
Branch Circuits Indoor Enclosure – Nema Type 1 Outdoor Enclosure – Nema Type 3R
Amp Rating
No. Of Spaces
No. Of Circuits
Catalog Number
Enclosure Height(Inches)
Catalog Number
Enclosure Height(Inches)
100 12 24 S1224B3100 24 — —
100 30 30 S3030B3100 30 — —
100 30 42 S3042B3100 30 — —
150 24 42 S2442B3150 36 SW2442B3150 35
150 42 42 S4242B3150 42 — —
200 30 54 S3054B3200 39 SW3054B3200 38
200 42 60 S4260B3200 42 SW4260B3200 42
225 42 42 S4242B3225 42 SW4242B3225 42
Main Breaker/Non-Convertible Load Centers Aluminum Bus12-70 circuits / 125-225 amperes 60/75° Rated 100,000A IR g
Branch Circuits Indoor Enclosure – Nema Type 1 Outdoor Enclosure – Nema Type 3R
Amp Rating
No. Of Spaces
No. Of Circuits
Catalog Number
Enclosure Height(Inches)
Catalog Number
Enclosure Height(Inches)
125 12 24 S1224L3125 21 SW1224L3125 21
150 18 36 S1836L3150 24 SW1836L3150 23
150 24 42 S2442L3150 30 SW2442L3150 27
200 12 24 S1224L3200 21 SW1224L3200 21
200 24 42 S2442L3200 30 SW2442L3200 27
200 30 54 S3054L3200 30 SW3054L3200 35
225 42 60 S4260L3225 36 SW4260L3225 38
225 54 70 S5470L3225 42 — —
May be installed on higher rated systems when protected by a circuit breaker with a higher AIR rating. Back fed main breaker. Indoor enclosures are 14 1/4” wide by 3 7/8” deep. Outdoor enclosures are 14 1/2” wide by 4 1/4” deep. Non-convertible to main breaker. Suitable for use as service entrance equipment when not more than six main disconnecting means are provided. See article 230.71 of the NEC®.g Rated 100,000A IR in series with breakers listed on wiring diagram.
ES™ Series Load Centers3-Phase Main Lug and Main Breaker Load Centers
3-Phase, 3-Wire, 240 Volt AC or 3-Phase, 4-Wire, 120/240 or 120/208 Volts AC
ES and PL Series Load Center Video
Load Center Mobile Webpage
Offering a full line of load centers, Siemens meets the needs of every application and all of your installation needs. From small load centers, riser panels and three phase load centers, to the PL and ES Series Load Centers™, Siemens has the highest quality, most complete offering on the market. Focusing on reliability, value and labor savings - Siemens is committed to increase productivity by reducing installation times.
24 www.sydist.com/SiemensMurray 24 www.sydist.com
Plug-In Circuit Breakers
Type QP with INSTA-WIRETM
Continuous Current Rating @ 40°C
1- Pole 120/240V AC Catalog Number
2 - Pole 120/240V AC Common Trip Catalog Number
2 - Pole 240V AC Common Trip Catalog Number
15 Q115 Q215 Q215R
20 Q120 Q220 Q220R
25 Q125 Q225 –
30 Q130 Q230 Q230R
35 Q135 g Q235 –
40 Q140 Q240 Q240R
45 Q145 g Q245 –
50 Q150 Q250 Q250R
60 Q160 Q260 Q260R
70 Q170 Q270 Q270R
80 – Q280 –
90 – Q290 –
100 – Q2100 Q2100R
110 – Q2110 –
125 – Q2125
Duplex Plug-In Circuit Breakers
Breaker Type
Ampere Rating 2-Pole
Catalog Number
QT 1-Pole 10k AIC 120V AC
15-15 Q1515
15-20 Q1520
20-20 Q2020
20-30 Q2030
15-30 Q3015 g
20-30 Q3020
30-30 Q3030
Ground-Fault Circuit Interrupters
Breaker Type
Ampere Rating
Catalog Number
QPF 1-Pole 120V AC Plug-in
15 QF115
20 QF120
25 QF125 g
30 QF130
QPF 2-Pole 120/240V AC Plug-in
15 QF215
20 QF220
30 QF230
40 QF240
50 QF250
60 QF260
UL listed as SWD (switching duty) rated. Suitable for 120V AC fluorescent lighting. HACR rated. For 22k AIC add “H” suffix. For 65k AIC add “HH” suffix. Contact factory for availability. White line neutral (pigtail) must be connected to the panel neutral for the device to function. g Built to order. Allow 2-3 weeks for delivery. Built to order. Allow 2–3 weeks for delivery.
Combination Type Arc-Fault Circuit Interrupters
1-Pole Plug-In Combination Type Arc-Fault Circuit Interrupters
Ampere Rating
Interrupting Rating
Ul Type
Catalog Number
15 10kAQAF2
QA115AFC
20 10kA QA120AFC
15 22kAQAFH2
QA115AFCH
20 22kA QA120AFCH
15 65kAHQAF2
QA115AFCHH
20 65kA QA120AFCHH
2-Pole Plug-In Combination Type Arc-Fault Circuit Interrupters
Ampere Rating
Interrupting Rating
Ul Type
Catalog Number
15 10kAQAF
Q215AFC
20 10kA Q220AFC
15 22kAQAFH
Q215AFCH
20 22kA Q220AFCH
www.sydist.com/SiemensMurray 2524 www.sydist.com
Plug-In Circuit Breakers
Type QP with INSTA-WIRETM
Continuous Current Rating @ 40°C
1- Pole 120/240V AC Catalog Number
2 - Pole 120/240V AC Common Trip Catalog Number
2 - Pole 240V AC Common Trip Catalog Number
15 Q115 Q215 Q215R
20 Q120 Q220 Q220R
25 Q125 Q225 –
30 Q130 Q230 Q230R
35 Q135 g Q235 –
40 Q140 Q240 Q240R
45 Q145 g Q245 –
50 Q150 Q250 Q250R
60 Q160 Q260 Q260R
70 Q170 Q270 Q270R
80 – Q280 –
90 – Q290 –
100 – Q2100 Q2100R
110 – Q2110 –
125 – Q2125
Duplex Plug-In Circuit Breakers
Breaker Type
Ampere Rating 2-Pole
Catalog Number
QT 1-Pole 10k AIC 120V AC
15-15 Q1515
15-20 Q1520
20-20 Q2020
20-30 Q2030
15-30 Q3015 g
20-30 Q3020
30-30 Q3030
Ground-Fault Circuit Interrupters
Breaker Type
Ampere Rating
Catalog Number
QPF 1-Pole 120V AC Plug-in
15 QF115
20 QF120
25 QF125 g
30 QF130
QPF 2-Pole 120/240V AC Plug-in
15 QF215
20 QF220
30 QF230
40 QF240
50 QF250
60 QF260
UL listed as SWD (switching duty) rated. Suitable for 120V AC fluorescent lighting. HACR rated. For 22k AIC add “H” suffix. For 65k AIC add “HH” suffix. Contact factory for availability. White line neutral (pigtail) must be connected to the panel neutral for the device to function. g Built to order. Allow 2-3 weeks for delivery. Built to order. Allow 2–3 weeks for delivery.
Combination Type Arc-Fault Circuit Interrupters
1-Pole Plug-In Combination Type Arc-Fault Circuit Interrupters
Ampere Rating
Interrupting Rating
Ul Type
Catalog Number
15 10kAQAF2
QA115AFC
20 10kA QA120AFC
15 22kAQAFH2
QA115AFCH
20 22kA QA120AFCH
15 65kAHQAF2
QA115AFCHH
20 65kA QA120AFCHH
2-Pole Plug-In Combination Type Arc-Fault Circuit Interrupters
Ampere Rating
Interrupting Rating
Ul Type
Catalog Number
15 10kAQAF
Q215AFC
20 10kA Q220AFC
15 22kAQAFH
Q215AFCH
20 22kA Q220AFCH
25www.sydist.com
Triplex Plug-In Circuit Breakers
Breaker Type
Ampere RatingCatalog Number2-Pole 1-Pole
QT 2-Pole 10k AIC 120/240V AC center common trip
15 15 Q21515CT
15 20 Q21520CT
15 25 Q21525CT
15 30 Q21530CT
15 35 Q21535CT
15 40 Q21540CT
15 45 Q21545CT
15 50 Q21550CT
20 20 Q22020CT
20 25 Q22025CT
20 30 Q22030CT
20 35 Q22035CT
20 40 Q22040CT
20 45 Q22045CT
20 50 Q22050CT
30 30 Q23030CT
Quadplex Plug-In Circuit Breakers
Breaker Type
Ampere Rating
Catalog Number
Inside 2-Pole
Outside 2-Pole
QT 2-Pole 10k AIC 120/240V AC common trip
15 15 Q21515CT2
15 20 Q22020CT2
20 30 Q22030CT2
20 40 Q22040CT2
30 30 Q23030CT2
30 40 Q23040CT2
40 40 Q24040CT2
50 30 Q25030CT2
Large Branch Circuit Breakers
Breaker Type
Ampere Rating
Catalog Number
Catalog Number
QN 2-Pole 120/240V AC
150 QN2150 QN2150R
175 QN2175 QN2175R
200 QN2200 QN2200R
QNH 2-Pole 120/240V AC
150 QN2150H QN2150RH
175 QN2175H QN2175RH
200 QN2200H QN2200RH
HQN 2-Pole 120/240V AC
150 HQN2150 HQN2150R
175 HQN2175 HQN2175R
200 HQN2200 HQN2200R
Main Breaker Kits
Description Catalog Number
Main breaker kit 100A 1PH QP 240V 22K MBK100A
Main breaker kit 125A 1PH QP 240V 22K MBK125A
Main breaker kit 150A 1PH QP 240V 22K MBK150A
Main breaker kit 200A 1PH QP 240V 22K MBK200A
Main breaker kit 225A 1PH QP 240V 22K MBK225A
Main breaker kit 100A 3PH QP 240V 10K MBK3100
Main breaker kit 150A 3PH QP 240V 10K MBK3125
Main breaker kit 150A 3PH 240V 10K MBK3150
Main breaker kit 175A 3PH 240V 10K MBK3175
Main breaker kit 200A 3PH 240V 10K MBK3200
Main breaker kit 225A 3PH 240V 10K MBK3225
Main breaker kit 125A 3PH 240V 22K MBK3125H
Main breaker kit 150A 3PH 240V 22K MBK3150H
Main breaker kit 175A 3PH 240V 22K MBK3175H
Main breaker kit 200A 3PH 240V 22K MBK3200H
Main breaker kit 225A 3PH 240V 22K MBK3225H
Main breaker kit 125A 3PH 240V 42K MBK3125HH
Main breaker kit 150A 3PH 240V 42K MBK3150HH
Main breaker kit 175A 3PH 240V 42K MBK3175HH
Main breaker kit 200A 3PH 240V 42K MBK3200HH
Main breaker kit 225A 3PH 240V 42K MBK3225HH
Plug-In Circuit Breakers cont.
Ground Bar Kits (For Es And Pl Load Centers)
Description Catalog Number
Ground bar kit - 8 pos EC1GB8
Ground bar kit - 8 pos, 2/0 lug EC1GB82
Ground bar kit - 12 pos EC2GB12
Ground bar kit - 12 pos, 2/0 lug EC2GB122
Ground bar kit - 15 pos EC2GB15
Ground bar kit - 15 pos, 2/0 lug EC2GB152
Ground bar kit - 21 pos EC3GB21
Ground bar kit - 21 pos, 2/0 lug EC3GB212
Ground bar kit - 27 pos EC3GB27
Ground bar kit - 27 pos, 2/0 lug EC3GB272
Ground bar kit - 30 pos EC3GB30
Ground bar kit - 30 pos, 2/0 lug EC3GB302
Ground bar kit - 35 pos, 2/0 lug EC3GB352
Hubs
Description Catalog Number
HS type closure plate ECHS000
HS type hub - 3/4” ECHS075
HS type hub - 1” ECHS100
HS type hub - 1 1/4” ECHS125
HS type hub - 1 1/2” ECHS150
HS type hub - 2” ECHS200
HS type hub - 2 1/2” ECHS250
HA type closure plate ECHA000
HA type hub - 3/4” ECHA075
HA type hub - 1” ECHA100
HA type hub - 1 1/4” ECHA125
HA type hub - 1 1/2” ECHA150
HV type closure plate ECHV000
HV type hub - 2” ECHV200
HV type hub - 2 1/2” ECHV250
HV type hub - 3” ECHV300
HV type hub - 3 1/2” ECHV350
HV type hub - 4” ECHV400
HACR rated. For 22k AIC add “H” suffix. Reverse handle.
Built to order. Allow 2-3 weeks for delivery. For 65k AIC add “H” prefix.
26 www.sydist.com/SiemensMurray 26 www.sydist.com
AC Disconnects
Ac Disconnects10,000A Ic Rated, Outdoor Type 3
1 Phase 120/240V AC
DescriptionCatalog Number
Pallet Quantity
60A Non-Fused WN2060 360
60A Fused WF2060 216
30A Fused WF2030 360
60A Non-automatic switch WNAS2060 360
Plastic AC Disconnects10,000A IC rated
1 Phase 120/240V AC
DescriptionCatalog Number
Pallet Quantity
60A Non-Fused WN2060PL 360
60A Fused WF2060PL 216
30A Fused WF2030PL 216
Ac Disconnects With GFCI ReceptacleOutdoor Type 3R
1 Phase 120/240V AC
DescriptionCatalog Number
Pallet Quantity
60A Non-Fused with 15A GFCI receptacle
WN2060GFCI 144
60A Fused with 15A GFCI receptacle WF2060GFCI 112
30A Fused with 15A GFCI receptacle WF2030GFCI 112
Non-automatic switch with 15A GFCI receptacle
WNAS2060GFCI 144
Fuses not included. To order in pallet quantities, place a “BP” at the end of the catalog number when ordering. Example: WN2060 WN2060BP.
www.sydist.com/SiemensMurray 2726 www.sydist.com
AC Disconnects
Ac Disconnects10,000A Ic Rated, Outdoor Type 3
1 Phase 120/240V AC
DescriptionCatalog Number
Pallet Quantity
60A Non-Fused WN2060 360
60A Fused WF2060 216
30A Fused WF2030 360
60A Non-automatic switch WNAS2060 360
Plastic AC Disconnects10,000A IC rated
1 Phase 120/240V AC
DescriptionCatalog Number
Pallet Quantity
60A Non-Fused WN2060PL 360
60A Fused WF2060PL 216
30A Fused WF2030PL 216
Ac Disconnects With GFCI ReceptacleOutdoor Type 3R
1 Phase 120/240V AC
DescriptionCatalog Number
Pallet Quantity
60A Non-Fused with 15A GFCI receptacle
WN2060GFCI 144
60A Fused with 15A GFCI receptacle WF2060GFCI 112
30A Fused with 15A GFCI receptacle WF2030GFCI 112
Non-automatic switch with 15A GFCI receptacle
WNAS2060GFCI 144
Fuses not included. To order in pallet quantities, place a “BP” at the end of the catalog number when ordering. Example: WN2060 WN2060BP.
27www.sydist.com
Ac Disconnects With GFCI ReceptacleOutdoor Type 3R
1 Phase 120/240V AC
DescriptionCatalog Number
Pallet Quantity
60A Non-Fused with 15A GFCI receptacle
WN2060GFCI 144
60A Fused with 15A GFCI receptacle WF2060GFCI 112
30A Fused with 15A GFCI receptacle WF2030GFCI 112
Non-automatic switch with 15A GFCI receptacle
WNAS2060GFCI 144
EQ Load Centers1 Phase. 3 Wire SN 120/240V AC
Breaker Used Indoor Enclosure - Nema Type 1 Outdoor Enclosure - Nema Type 3R
Frame TypeAmpere Rating
No. Of Poles
Catalog Number
Std. Pkg.
Dimensions (Inches)
Catalog Number
Std. Pkg.
Dimensions (Inches)
H W D H W D
QP, QPH, HQP
60
60
100
125
2
2
2
2
E0204ML1060S
E0204ML1060F
E0202MB1100
E0204ML1125SCU
5
5
1
1
9 7/8
9 7/8
17 1/8
17 1/8
5 1/8
5 1/8
7 3/8
7 1/8
2 5/8
2 5/8
4 5/16
4 1/4
W0204ML1060
-
W0202MB1100CU
W0204ML1125CU
5
-
1
1
8
-
17.4
17 1/8
5
-
7.3
7 3/8
4 1/4
-
4.3
4 5/16
QN, QNH, HQN
150
200
200
2
2
2
-
-
E0202MB1200
-
-
-
-
-
19 3/8
-
-
8 1/2
-
-
4
W0202MB1150CU
W0202ML1200CU
W0202MB1200CU
1
1
1
19 3/4
19 3/4
19 3/4
8.4
8.4
8.4
4.6
4.6
4.6
QPP, QPPH, HQPP, QP
225 1-4 - - - - - W0406ML1225CU 1 23 10 4 1/8
Will not accommodate 2-pole GFCI or circuit breaker with shunt trip. 42,000A IR maximun. Copper wire only at 225A. Main breaker factory installed. CSA Listed.
EQ Load Centers
www.usa.siemens.com/powerdistribution
Subject to change without prior notice Order No. PDSA-SCHYS-0115 Printed in USAAll rights reserved © 2015 Siemens Industry, Inc.
Siemens Industry, Inc.5400 Triangle ParkwayNorcross, GA 30092
The information provided in this brochure contains me re ly general descriptions or characteristics of per for m ance which in ac tual case of use do not always ap ply as described or which may change as a result of fur ther de ve lopment of the pro ducts. An obligation to provide the respective characteristics shall only exist if ex pressly agreed in the terms of contract. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.
Schaedler Yesco Distribution, Inc.3982 Paxton St.Harrisburg, PA 17111
www.sydist.com