electromagnetic and-electronic-circuitbreaker-[technolead]

42
Welcome to PHOENIX CONTACT Electromagnetic and electronic circuit- breaker CLIPLINE complete

Upload: neha-bandhu

Post on 12-Apr-2017

320 views

Category:

Business


4 download

TRANSCRIPT

Page 1: Electromagnetic and-electronic-circuitbreaker-[technolead]

Welcome to PHOENIX CONTACT

Electromagnetic and electronic circuit-breaker

CLIPLINE complete

Page 2: Electromagnetic and-electronic-circuitbreaker-[technolead]

2 / Name / Department / Date

UT 6-TMC M 0,5A………………………UT 6-TMC M 16A

Circuit Breaker UT 6-TMC M

Thermomagnetic Circuit

Breaker as part of CLIPLINE complete

UT 6-TMC M 0,5AUT 6-TMC M 1AUT 6-TMC M 2AUT 6-TMC M 4AUT 6-TMC M 5AUT 6-TMC M 6AUT 6-TMC M 8AUT 6-TMC M 10AUT 6-TMC M 12AUT 6-TMC M 15AUT 6-TMC M 16A

Highlights

Page 3: Electromagnetic and-electronic-circuitbreaker-[technolead]

3 / Name / Department / Date

Circuit Breaker UT 6-TMC M

Two bridge channels for the standard FBS x-6 bridge

Due to the plug bridge no need for wiring

Time-saving

Page 4: Electromagnetic and-electronic-circuitbreaker-[technolead]

4 / Name / Department / Date

38

37

-F18

Circuit Breaker UT 6-TMC M

Three positions for UC-TM12 or ZB 12 marking material. Enough space for big and easy readable designations.

Clear marking for device and connection point information

Fast and clear marking

Page 5: Electromagnetic and-electronic-circuitbreaker-[technolead]

5 / Name / Department / Date

Circuit Breaker UT 6-TMC M

Exact positioning of all markers

High quality impression

Page 6: Electromagnetic and-electronic-circuitbreaker-[technolead]

6 / Name / Department / Date

Circuit Breaker UT 6-TMC M

30% less space required

Space-saving12,3 17,5

Page 7: Electromagnetic and-electronic-circuitbreaker-[technolead]

7 / Name / Department / Date

Circuit Breaker UT 6-TMC M

If the circuit breaker is switched „off“ you can see the white collar.

Clear visibility of the switching status. This allows a fast identification of the faulty circuit.

High availability

Page 8: Electromagnetic and-electronic-circuitbreaker-[technolead]

8 / Name / Department / Date

Circuit Breaker UT 6-TMC M

No competitive product in the market

Phoenix Contact product

Page 9: Electromagnetic and-electronic-circuitbreaker-[technolead]

9 / Name / Department / Date

CertificationBody Standard Approved as File-No. Approval Mark

VDE IEC 60934 Circuit Breaker for Equipment

UL UL 1077 SupplementaryProtector

UL CSA 22.2 No. 235 SupplementaryProtector

Approvals

Circuit Breaker UT 6-TMC M

Page 10: Electromagnetic and-electronic-circuitbreaker-[technolead]

10 / Name / Department / Date

mains input

power supply

24 V DC

magnetic valves, signal lamps, heating systems, industrial PC´s, fans…

Application

main application for UT 6-TMC M

Page 11: Electromagnetic and-electronic-circuitbreaker-[technolead]

11 / Name / Department / Date

Circuit Breaker – Product Range

TCPTMC TMCP

ECP-E

TCP/DC

ECP EC-E

Page 12: Electromagnetic and-electronic-circuitbreaker-[technolead]

12 / Name / Department / Date

Circuit Breaker

Thermomagnetic protection

Thermal protection

Electronic protection

Page 13: Electromagnetic and-electronic-circuitbreaker-[technolead]

13 / Name / Department / Date

Circuit Breaker - Shut-down behavior

Thermal

Thermal&

magnetic

Electronic

Short Circuit ApplicationOverload

Over-load

Page 14: Electromagnetic and-electronic-circuitbreaker-[technolead]

14 / Name / Department / Date

Thermal Switch-offTCP

Switching capacity

Nominal current

Voltage

Marking

Switching function

max. 8 x IN

0.1 A – 10 A

AC 250 V / DC 65 V

Yes

On & off switch incl. electric isolation

TCP...

Page 15: Electromagnetic and-electronic-circuitbreaker-[technolead]

15 / Name / Department / Date

Thermal Switch-offTCP-Applications

Safeguarding of inductive loads

Fan Motors Heating elements

Page 16: Electromagnetic and-electronic-circuitbreaker-[technolead]

16 / Name / Department / Date

Thermal Switch-offTCP - comparison

Switching capacity

Nominal current

Voltage

Marking

Switching function

150 A

5 A – 30 A

DC 32 V

NoCan be switched back on

again incl. electric isolation

max. 8 x IN

0.1 A – 10 A

AC 250 V / DC 65 V

YesOn & off switch incl.

electric isolation

TCP... TCP.../DC32V

Page 17: Electromagnetic and-electronic-circuitbreaker-[technolead]

17 / Name / Department / Date

Thermal Switch-offTCP/DC - Areas of applications

Protection of DC board and battery systems

Cars & Trucks Shipbuilding Industry

Page 18: Electromagnetic and-electronic-circuitbreaker-[technolead]

18 / Name / Department / Date

Thermal Switch-offTCP – Socket und accessoires

UK 6-FSI/C UK 4-FSI/C

Page 19: Electromagnetic and-electronic-circuitbreaker-[technolead]

19 / Name / Department / Date

Circuit Breaker

Thermomagnetic protection

Thermal protection

Electronic protection

Page 20: Electromagnetic and-electronic-circuitbreaker-[technolead]

20 / Name / Department / Date

Thermal

Thermal&

magnetic

Electronic

Short Circuit ApplicationOverload

Over-load

Over-load,

Short circuit

Circuit Breaker - Shut-down behavior

Page 21: Electromagnetic and-electronic-circuitbreaker-[technolead]

21 / Name / Department / Date

Magnetic Switch-offTMC - Comparison

Switching capacity

Nominal current

Nominal voltage

Shut-down behavior

Approbation

Width

TMC...max. 800 A

0.2A...16A

AC 250V / DC 65V

Fast blow and normal

UL 1077

12.5 mm

max. 800 A

0,5A...16A

AC 240V / DC 28V

normal

UL 1077

12,3 mm

UT 6-TMC...

Page 22: Electromagnetic and-electronic-circuitbreaker-[technolead]

22 / Name / Department / Date

Magnetic Switch-offTMCP Socket and Accessoires

Fixed bridge pluggableFBST 500 TMCP

Socket – 2-positionTMCP Socket M

Termination elementTMCP Connect LR

Signal bridge for freeslots TMCP SB

Page 23: Electromagnetic and-electronic-circuitbreaker-[technolead]

23 / Name / Department / Date

Device protection with system

Thermomagnetic Circuit Breakerat the CLIPLINE complete Push-In-System

Page 24: Electromagnetic and-electronic-circuitbreaker-[technolead]

24 / Name / Department / Date

Magnetic Switch-offTMC & TMCP-Applications

Industry Plant construction Machine building

Secondary protection for industrial systems

Page 25: Electromagnetic and-electronic-circuitbreaker-[technolead]

25 / Name / Department / Date

Circuit Breaker

Thermomagnetic protection

Thermal protection

Electronic protection

Page 26: Electromagnetic and-electronic-circuitbreaker-[technolead]

26 / Name / Department / Date

Circuit Breaker - Shut-down behavior

Thermal

Thermal&

magnetic

Electronic

Short Circuit ApplicationOverload

Over-load

Over-load,

Short circuit

Over-load,

Short circuitAttenuation/Capacity1.8 x IN1.8 x IN

Page 27: Electromagnetic and-electronic-circuitbreaker-[technolead]

27 / Name / Department / Date

Electronic Switch-offECP - comparison

Voltage

Nominal current

Current limiting

Elec. Isolation

Assembly

ECPDC 24V

1A...10A

1.8 x IN

YesPluggable onTMCP-Socket-M

Page 28: Electromagnetic and-electronic-circuitbreaker-[technolead]

28 / Name / Department / Date

Voltage

Nominal current

Current limiting

Elec. Isolation

Assembly

DC 24V

1A...10A

1.8 x IN

YesPluggable on TMCP-Socket-M

ECP ECP-E...DC 24V

1A...12A

1.8 x IN

NoPluggable on TMCP-Socket-M

Electronic Switch-offECP - Comparison

Page 29: Electromagnetic and-electronic-circuitbreaker-[technolead]

29 / Name / Department / Date

Electronic Switch-offECP - Comparison

Voltage

Nominal current

Current limiting

Elec. Isolation

Assembly

DC 24V

1A...12A

1.8 x IN

NoDin-Rail

mountable

DC 24V

1A...10A

1.8 x IN

YesPluggable on TMCP-Socket-M

EC-E...ECP ECP-E...DC 24V

1A...12A

1.8 x IN

NoPluggable on TMCP-Socket-M

Page 30: Electromagnetic and-electronic-circuitbreaker-[technolead]

30 / Name / Department / Date

EC-EECP-EECP

Productrange Circuit Breaker

Page 31: Electromagnetic and-electronic-circuitbreaker-[technolead]

31 / Name / Department / Date

Electronic Switch-offEC(P) Applications

Plant construction Machine building24 VDC-circuits

Controllable secondary protection with status signal

Page 32: Electromagnetic and-electronic-circuitbreaker-[technolead]

32 / Name / Department / Date

AC-area

change

DC-area

distribute

Application

Page 33: Electromagnetic and-electronic-circuitbreaker-[technolead]

33 / Name / Department / Date

Specific Characteristic

The power is limited

VS.

Page 34: Electromagnetic and-electronic-circuitbreaker-[technolead]

34 / Name / Department / Date

How to define the circuit breaker?

What is the load behavior?

Transmission – how long is the wire?

How much space is available?

Specific Characteristic

Page 35: Electromagnetic and-electronic-circuitbreaker-[technolead]

35 / Name / Department / Date

What is the loads behavior?

MCB EC-EResistance ohmic

Capacities

Induktiv loads

A, B, C, D

C, D

B, C, D

Specific Characteristic

Page 36: Electromagnetic and-electronic-circuitbreaker-[technolead]

36 / Name / Department / Date

Cable Length

Nominal C, 6 A 6A

Short Cicuit Area >7-times 1,8-times

Trip Current >42 A ~11 A

Max. Resistance 24V/42A= 0,57 Ohm 24V/11A= 2,18 Ohm

Length at 1,0mm² 15 meter 50 meter

Length at 0,5mm² 5 meter 30 meter

Length at 0,34mm² effects source 20 meter

MCB EC-E

Transmission – How long is the wire?

Page 37: Electromagnetic and-electronic-circuitbreaker-[technolead]

37 / Name / Department / Date

Assembly

How much space is available?

62,5mm : 5pol = 12,5mm

175mm : 5pol = 35mm

Page 38: Electromagnetic and-electronic-circuitbreaker-[technolead]

38 / Name / Department / Date

Technical parameter

Page 39: Electromagnetic and-electronic-circuitbreaker-[technolead]

39 / Name / Department / Date

Distribution up to 63 A

Technical parameter

Page 40: Electromagnetic and-electronic-circuitbreaker-[technolead]

40 / Name / Department / Date

Group-signalling with plug-in bridges

Technical parameter

Page 41: Electromagnetic and-electronic-circuitbreaker-[technolead]

41 / Name / Department / Date

Technical parameter

Page 42: Electromagnetic and-electronic-circuitbreaker-[technolead]

42 / Name / Department / Date

All at a glace Small and compact design Energy-saving by current limitation Secure on long wires Easy assembly by pluggable

bridges Highest value at capacities Distribution up to 50 A