Pavel Tlustý , NPI Řež. Electromagnetic Calorimeter for HADES at SIS100. Involved groups: Jag. University Krakow INR Moscow NPI Rez …… ?. Motivation Plans Current s tatus Tests Outlook. May 8, 2009. HADES Collaboration Meeting, Sesimbra, May 5-10, 2009. Motivation. - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: Electromagnetic Calorimeter for HADES at SIS100](https://reader035.vdocuments.net/reader035/viewer/2022062221/5681354f550346895d9caca3/html5/thumbnails/1.jpg)
Electromagnetic Calorimeter for HADES at SIS100
Pavel Tlustý, NPI Řež
• Motivation
• Plans
• Current status
• Tests
• Outlook
HADES Collaboration Meeting, Sesimbra, May 5-10, 2009 May 8, 2009
Involved groups:
• Jag. University Krakow
• INR Moscow
• NPI Rez
• …… ?
![Page 2: Electromagnetic Calorimeter for HADES at SIS100](https://reader035.vdocuments.net/reader035/viewer/2022062221/5681354f550346895d9caca3/html5/thumbnails/2.jpg)
MotivationMotivation
- measurements of the respective º and η meson two gamma decay yields together with the dielectron data for the knowledge of dielectron coctail and normalization at incident heavy ion energies 2-8 AGeV
- better electron/pion suppression for large momenta (p>400 MeV/c) as compared to the present situation (at lower momenta the electron/hadron identification will be provided by the RICH and RPC)
![Page 3: Electromagnetic Calorimeter for HADES at SIS100](https://reader035.vdocuments.net/reader035/viewer/2022062221/5681354f550346895d9caca3/html5/thumbnails/3.jpg)
MotivationMotivation
Eur. Phys. J. C 4, 231-247 (1998)
Eur. Phys. J. C 4, 249-257 (1998)
![Page 4: Electromagnetic Calorimeter for HADES at SIS100](https://reader035.vdocuments.net/reader035/viewer/2022062221/5681354f550346895d9caca3/html5/thumbnails/4.jpg)
Side View
START
HADES & EMC
RPC
EMC
The total area required for a HADES calorimeter amounts to about 8m2 !!
ElectroMagnetic Calorimeter (EMC) will replace the HADES Pre-Shower detector (18º< Θ< 45º).
![Page 5: Electromagnetic Calorimeter for HADES at SIS100](https://reader035.vdocuments.net/reader035/viewer/2022062221/5681354f550346895d9caca3/html5/thumbnails/5.jpg)
Detector modules Our proposal is to use lead glass modules from OPAL end cap calorimeter.~ 900 modules needed, at present (April 2009) 1080 modules moved to GSI.
Energy resolution ~ 5%/sqrt(E), E in GeV
Lead glass properties:- type: CEREN 25- chemical composition (SiO2 -39%,PbO – 55%, K2 - 2%, Na20 – 3%) - density: 4.o6 g/cm3- radiation length (X0): 2.51 cm- refractive index: 1.708 (at 400 nm)
Nucl. Instr. Meth. A290, 76 (1990)
Moduledimensions:42 x 9 x 9 cm
![Page 6: Electromagnetic Calorimeter for HADES at SIS100](https://reader035.vdocuments.net/reader035/viewer/2022062221/5681354f550346895d9caca3/html5/thumbnails/6.jpg)
Signal Read-out
PMT Diameter of photocathode
(mm)
XP2262 44
FEU-110-1 63
FEU-139 63
EMI 9903KB 34
PMT - EMI 9903KB (1.5'') from MIRAC (WA98 hadron calorimeter) ~720 PMT'sdiameter – 38 mm (1.5'')diameter of photocathode – 34 mm
Front-end readout – ADC ADD-ON (Shower)+ TRB
![Page 7: Electromagnetic Calorimeter for HADES at SIS100](https://reader035.vdocuments.net/reader035/viewer/2022062221/5681354f550346895d9caca3/html5/thumbnails/7.jpg)
Design • Number of modules 150x6=900• Mass of one module of lead-glass 14 kg• Total mass of cal. 12600 kg
E. Lisowski, TU Krakow
![Page 8: Electromagnetic Calorimeter for HADES at SIS100](https://reader035.vdocuments.net/reader035/viewer/2022062221/5681354f550346895d9caca3/html5/thumbnails/8.jpg)
Tests
Source – cosmics muons: energy ≈ 2 GeV, energy deposit in module ≈ 200 MeV, Cerenkov light output corresponds to ≈ 400 MeV electrons count rate ≈ 30 particles / hour
Measurement of pulse height (ADC) spectra – check of energy resolution
various PMTs, configuration with/without lightguide
Oct. 2008 - test of various PMTsApr. 2009 - test of lightguide
![Page 9: Electromagnetic Calorimeter for HADES at SIS100](https://reader035.vdocuments.net/reader035/viewer/2022062221/5681354f550346895d9caca3/html5/thumbnails/9.jpg)
Cosmic test setup
lead glass module
trigger detectors
count rate: ~ 30 particles / hour
![Page 10: Electromagnetic Calorimeter for HADES at SIS100](https://reader035.vdocuments.net/reader035/viewer/2022062221/5681354f550346895d9caca3/html5/thumbnails/10.jpg)
Cosmic test – various PMTsPMT Diameter of
photocathode
(mm)
energy
resolution (%)
Number of photoelectrons
XP2262
(from FW)
44 14.4 48
FEU-110-1
63 11.9 70
FEU-139 63 9.4 112
EMI 9903KB
34 10.6 88
σ/Nmean= 10.6 %or Nph.el > 88
Nph.el. ≈ 1/ σ2
EMI 9903KB
![Page 11: Electromagnetic Calorimeter for HADES at SIS100](https://reader035.vdocuments.net/reader035/viewer/2022062221/5681354f550346895d9caca3/html5/thumbnails/11.jpg)
Assembling of lead glass modules with lightguide and
PMTOPAL lead glass module 420 mm lengthplexiglass lightguidePMTHV divider
plexiglas lightguidePMT
![Page 12: Electromagnetic Calorimeter for HADES at SIS100](https://reader035.vdocuments.net/reader035/viewer/2022062221/5681354f550346895d9caca3/html5/thumbnails/12.jpg)
Cosmic test – PMT pulseswith lightguide without lightguide
Light collection with lightguide in average 3 times worse than direct PMT-glass connectionNew lightguide from lead glass to be tested, better shape?
A ≈ 500 mVcosmic muons correspond to ≈ 400 MeV e-
![Page 13: Electromagnetic Calorimeter for HADES at SIS100](https://reader035.vdocuments.net/reader035/viewer/2022062221/5681354f550346895d9caca3/html5/thumbnails/13.jpg)
σ/Nmean= 10.6 %or Nph.el > 88
with lightguide without lightguide
σ/Nmean ≈ 40% without lightguide (Oct 2008)
Cosmic test – ADC spectra
Nph.el. ≈ 1/ σ2
![Page 14: Electromagnetic Calorimeter for HADES at SIS100](https://reader035.vdocuments.net/reader035/viewer/2022062221/5681354f550346895d9caca3/html5/thumbnails/14.jpg)
σ/Nmean= 10.6 %
our data
Cosmic muon ADC spectra
http://www.e835.to.infn.it/people/gollwitz/thesis/K. Gollwitzer, PhD thesis, University of California at Irvine, 1993
Fermilab E760 Central Calorimeter
σ/Nmean≈ 7 %
OPAL e- 1 GeV Np.e. ≈ 1800 ≈ 5%
E760 e- 1 GeV Np.e. ≈ 4250 ≈ 5%
E760 ≈ 2 GeV Np.e. ≈ 2082 ≈ 7%
module length 50 cm
![Page 15: Electromagnetic Calorimeter for HADES at SIS100](https://reader035.vdocuments.net/reader035/viewer/2022062221/5681354f550346895d9caca3/html5/thumbnails/15.jpg)
Tests - plans
May – June - Cosmic muons, test of lightguide
June – July - Electron beam @ MAMI response to 100 – 2000 MeV electrons up to 8 modules, various configurations
![Page 16: Electromagnetic Calorimeter for HADES at SIS100](https://reader035.vdocuments.net/reader035/viewer/2022062221/5681354f550346895d9caca3/html5/thumbnails/16.jpg)
PMT Tests
PMT EMI 9903KB (1.5'') ~720 PMTs available 500 PMTs tested
HV dependence of PMT response:
PMT alone at HV=1500 and 1700 V,PMT with a gamma-source 22Na at HV=1200, 1500, and 1700 V;
The results for HV=1500 V: <500 mV 79 pieces of PMTs 16% 500 mV < U < 1500 mV 120 pieces of PMTs1500 mV < U < 2700 mV 191 pieces of PMTs>2700 mV 110 pieces of PMTs
![Page 17: Electromagnetic Calorimeter for HADES at SIS100](https://reader035.vdocuments.net/reader035/viewer/2022062221/5681354f550346895d9caca3/html5/thumbnails/17.jpg)
Summary
motivation: improved dilepton spectroscopy by HADES lepton and photon pairs at the same time
current status detector modules available
PMT – 70% available, 70% of them tested tests with cosmics going on simulation in progress - see next talk mechanical construction designed plans
tests on electron beam (and cosmics) fixing the detector module setup building one sector building full calorimeter