Electromagnetic Compatibility Test Report Test Report No.: K10501/E17 (Ref. no.: UCSCE-1708-105) Page 1 of 1 Certification Authority: TÜV NORD Korea Ltd. 20 Dogok-ro 3gil (Yeoksam-dong), Gangnam-gu, Seoul 06254, Korea Testing Laboratory: UCS Co., Ltd. #702, 268, Hagui-ro, Dongan-gu, Anyang-si, Gyeonggi-do, 14056, Korea Applicant: Hanseo Precision Meter Co., Ltd. 61, Seungga-ro 76beon-gil, Gimpo-si, Gyeonggi-do 10117, Korea Manufacturer: Same as applicant Test Item: Electric type water saving pedal Serial No.: Prototype Identification: CS320A Date of receipt: 15.09.2017 File Ref. No.: KP-17-415 Date(s) of test: 24.08.2017 ~ 25.08.2017 Test Specification: EN 55014-1:2006 + A1 + A2:2011 EN 55014-2:1997 + A1 + A2:2008 EN 61000-3-2:2014 EN 61000-3-3:2013 Test Result: The a. m. test item passed the test specification. Remarks: This test report relates to the a. m. test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any safety mark on this or similar products. Enclosure: UCS report no. UCSCE-1708-105 Compiled by: Date: Signature: Yong-Cheon Kim TÜV NORD Korea 28. 09. 2017 ………………………………………… Approved by: Date: Signature: Won-Wook Kim TÜV NORD Korea 28. 09. 2017 ……………………………………… TÜV NORD Korea Ltd. 20 Dogok-ro 3gil (Yeoksam-dong), Gangnam-gu, Seoul 06254, Korea Tel: ++82-2188-0070 Fax: ++82-2-556-3065 E-mail: [email protected] web: www.tuv-nord.com/kr/ko

Upload: others

Post on 02-Aug-2020

39 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Electromagnetic Compatibility Test Reporthanseointernational.com/wp-content/...Test-Report.pdf · Test Specification: EN 55014-1:2006 + A1 + A2:2011 EN 55014-2:1997 + A1 + A2:2008

Electromagnetic Compatibility Test Report

Test Report No.: K10501/E17 (Ref. no.: UCSCE-1708-105)

Page 1 of 1

Certification Authority:

TÜV NORD Korea Ltd.

20 Dogok-ro 3gil (Yeoksam-dong), Gangnam-gu, Seoul 06254, Korea

Testing Laboratory: UCS Co., Ltd.

#702, 268, Hagui-ro, Dongan-gu, Anyang-si, Gyeonggi-do, 14056, Korea

Applicant: Hanseo Precision Meter Co., Ltd.

61, Seungga-ro 76beon-gil, Gimpo-si, Gyeonggi-do 10117, Korea

Manufacturer: Same as applicant

Test Item: Electric type water saving pedal Serial No.: Prototype

Identification: CS320A Date of receipt: 15.09.2017

File Ref. No.: KP-17-415 Date(s) of test: 24.08.2017 ~ 25.08.2017

Test Specification: EN 55014-1:2006 + A1 + A2:2011 EN 55014-2:1997 + A1 + A2:2008 EN 61000-3-2:2014 EN 61000-3-3:2013

Test Result: The a. m. test item passed the test specification.

Remarks:

This test report relates to the a. m. test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any safety mark on this or similar products.

Enclosure: UCS report no. UCSCE-1708-105

Compiled by: Date:

Signature:

Yong-Cheon Kim TÜV NORD Korea 28. 09. 2017

…………………………………………

Approved by: Date:

Signature:

Won-Wook Kim TÜV NORD Korea 28. 09. 2017

………………………………………

TÜV NORD Korea Ltd. 20 Dogok-ro 3gil (Yeoksam-dong), Gangnam-gu, Seoul 06254, Korea Tel: ++82-2188-0070 Fax: ++82-2-556-3065 E-mail: [email protected] web: www.tuv-nord.com/kr/ko

Page 2: Electromagnetic Compatibility Test Reporthanseointernational.com/wp-content/...Test-Report.pdf · Test Specification: EN 55014-1:2006 + A1 + A2:2011 EN 55014-2:1997 + A1 + A2:2008

Global No.1 Testing Laboratory Universal Certification Solution

EMC TEST REPORT

Product name: Electric type water saving pedal

Model(s): CS320A Standards: EN 55014-1:2006+A1:2009+A2:2011

EN 55014-2:1997+A1+A2:2008

EN 61000-3-2:2014

EN 61000-3-3:2013

Applicant: Hanseo Precision Meter co.,LTD

Test Report No.: UCSCE-1708-105

UCS Co., Ltd.

#702, 268, Hagui-ro, Dongan-gu, Anyang-si, Gyeonggi-do, 14056, Korea.

Tel: +82-1833-5681 / Fax: +82-31-420-5685 / Open Site: +82-31-355-2666

Online: http://www.ucs.co.kr

KOREATÜV NORD GROUP

ReviewedSpot checkedWitnessed by AuthorizedInspector

Kim, Won-Wook

Page 3: Electromagnetic Compatibility Test Reporthanseointernational.com/wp-content/...Test-Report.pdf · Test Specification: EN 55014-1:2006 + A1 + A2:2011 EN 55014-2:1997 + A1 + A2:2008

KOREATÜV NORD GROUP

ReviewedSpot checkedWitnessed by AuthorizedInspector

Kim, Won-Wook

Page 4: Electromagnetic Compatibility Test Reporthanseointernational.com/wp-content/...Test-Report.pdf · Test Specification: EN 55014-1:2006 + A1 + A2:2011 EN 55014-2:1997 + A1 + A2:2008

Page: 3 of 38 Report Number: UCSCE-1708-105

발 급 번 호 : U C SKE -

UQE-TRF-01(Rev.0)

Contents

1. Applicant Information ..................................................................................................................................................... 4

2. EUT (Equipment under test) Information........................................................................................................................ 4

3. Laboratory Information ................................................................................................................................................... 4

4. Test Configuration and Condition ................................................................................................................................... 5

5. Summary of Test Results ................................................................................................................................................. 6

6. Test Results...................................................................................................................................................................... 7

7. EUT Photos ................................................................................................................................................................... 34

Revision History

Issued Report No. Issued Date Revisions Effect Section

UCSCE-1708-105 31-Aug-2017 Initial Issue All

KOREATÜV NORD GROUP

ReviewedSpot checkedWitnessed by AuthorizedInspector

Kim, Won-Wook

Page 5: Electromagnetic Compatibility Test Reporthanseointernational.com/wp-content/...Test-Report.pdf · Test Specification: EN 55014-1:2006 + A1 + A2:2011 EN 55014-2:1997 + A1 + A2:2008

Page: 4 of 38 Report Number: UCSCE-1708-105

발 급 번 호 : U C SKE -

UQE-TRF-01(Rev.0)

1. Applicant Information

Applicant Name : Hanseo Precision Meter co.,LTD

Address : 61, Seungga-ro 76beon-gil, Gimpo-si, Gyeonggi-do

Manufacturer : Hanseo Precision Meter co.,LTD

Address : 61, Seungga-ro 76beon-gil, Gimpo-si, Gyeonggi-do

2. EUT (Equipment under test) Information

Product Name : Electric type water saving pedal

Basic Model Name : CS320A

Rated voltage : 230 V, 50 Hz, AA size 4ea DC 6 V

Power consumption : 2 mA (ordinary time), 322 mA (Using)

Size : Pedal switch 270 x 60 x 12, Control box 128 x 80 x 78

* Product specification information described herein was obtained from product data sheet or user’s manual.

3. Laboratory Information

Laboratory Name : UCS Co., Ltd.

Location : 35-13, Hwalcho-gil, 109beon-gil, Hwaseong-si, Gyeonggi-do, 18278, Korea

KOREATÜV NORD GROUP

ReviewedSpot checkedWitnessed by AuthorizedInspector

Kim, Won-Wook

Page 6: Electromagnetic Compatibility Test Reporthanseointernational.com/wp-content/...Test-Report.pdf · Test Specification: EN 55014-1:2006 + A1 + A2:2011 EN 55014-2:1997 + A1 + A2:2008

Page: 5 of 38 Report Number: UCSCE-1708-105

발 급 번 호 : U C SKE -

UQE-TRF-01(Rev.0)

4. Test Configuration and Condition

4.1 EUT operating condition

- After connecting a peripherals to the EUT, the EUT was operated continuously during the test.

- Input power condition during the measurements was 230 V~, 50 Hz.

4.2 EUT test configuration diagram

4.3 Peripheral equipments list for test

Equipment Name Model Serial Number Manufacturer

Control box (EUT) CS320A - Hanseo Precision Meter

co.,LTD

Pedal switch (EUT) CS320A - Hanseo Precision Meter

co.,LTD

AC Adapter (EUT) KNV-1210EU - HUMAN-TEC CO..

4.4 Cable connections

Start End Cable

Name I/O Port Name I/O Port Length (m) Spec.

Control box

(EUT)

Control cable Pedal switch

(EUT) Control cable 1.9 Unshielded

DC in AC Adapter

(EUT) DC out 1.4 Unshielded

4.5 EUT modifications

- None

KOREATÜV NORD GROUP

ReviewedSpot checkedWitnessed by AuthorizedInspector

Kim, Won-Wook

Page 7: Electromagnetic Compatibility Test Reporthanseointernational.com/wp-content/...Test-Report.pdf · Test Specification: EN 55014-1:2006 + A1 + A2:2011 EN 55014-2:1997 + A1 + A2:2008

Page: 6 of 38 Report Number: UCSCE-1708-105

발 급 번 호 : U C SKE -

UQE-TRF-01(Rev.0)

5. Summary of Test Results

5.1 Summary of test results

Standard Test Item Results

EN 55014-1:2006 + A1:2009

+ A2:2011

Mains terminal continuous disturbance voltage Met / PASS

Mains terminal discontinuous disturbance voltage Met / PASS

Disturbance Power N/A (See note 1)

Radiated disturbance Met / PASS

EN 61000-3-2:2014 Harmonics current emissions Met Class A / PASS

EN 61000-3-3:2013 Voltage changes, Voltage fluctuations and flicker Met / PASS

EN 55014-2: 1997+A1

+A2:2008 (Category II)

Electrostatic Discharge Met Criterion A / PASS

Radiated RF electromagnetic field immunity N/A (See note 2)

Electrical Fast Transient/Burst Immunity Met Criterion A / PASS

Surge Immunity Met Criterion A / PASS

Conducted RF Field Immunity (Injected currents) Met Criterion A / PASS

Voltage Dips, Short Interruptions Immunity Met Criterion A / PASS

* Note 1: This test is not performed because the EUT is tested to radiated disturbance.

* Note 2: This test is not performed because the EUT is category II.

5.2 Performance of criteria

Performance criterion A

The apparatus shall continue to operate as intended during the test. No degradation of performance or loss of function

is allowed below a performance level (or permissible loss of performance) specified by the manufacturer, when the

apparatus is used as intended. If the minimum performance level or the permissible performance loss is not specified

by the manufacturer, then either of these may be derived from the product description and documentation, and from

what the user may reasonably expect from the apparatus if used as intended.

Performance criterion B

The apparatus shall continue to operate as intended after the test. No degradation of performance or loss of function is

allowed below a performance level (or permissible loss of performance) specified by the manufacturer, when the

apparatus is used as intended. During the test, degradation of performance is allowed, however, no change of actual

operating state or stored data is allowed to persist after the test. If the minimum performance level or the permissible

performance loss is not specified by the manufacturer, then either of these may be derived from the product

description and documentation, and from what the user may reasonably expect from the apparatus if used as intended.

Performance criterion C

Temporary loss of function is allowed, provided the function is self- recoverable or can be restored by the operation of

the controls, or by any operation specified in the instructions for use.

KOREATÜV NORD GROUP

ReviewedSpot checkedWitnessed by AuthorizedInspector

Kim, Won-Wook

Page 8: Electromagnetic Compatibility Test Reporthanseointernational.com/wp-content/...Test-Report.pdf · Test Specification: EN 55014-1:2006 + A1 + A2:2011 EN 55014-2:1997 + A1 + A2:2008

Page: 7 of 38 Report Number: UCSCE-1708-105

발 급 번 호 : U C SKE -

UQE-TRF-01(Rev.0)

6. Test Results

6.1 Mains terminal continuous disturbance voltage

Test Standard EN 55014-1:2006/A2:2011

Tested Date 2017.08.24

Input Ratings 230 V~, 50 Hz

Temperature 24.7 °C Humidity 63.9 % R.H.

Test result Met / Pass

6.1.1 Limit

Frequency

[MHz]

Mains terminals Load and additional terminals

Quasi-Peak [dBμV] Average [dBμV] Quasi-Peak [dBμV] Average [dBμV]

0.15 ~ 0.5 66 ~ 56* 59 ~ 46* 80 70

0.5 ~ 5 56 46 74 64

5 ~ 30 60 50 74 64

* The limit decreases linearly with the logarithm of frequency.

6.1.2 Test set-up and procedure

The mains terminal disturbance voltage was measured with the equipment under test (EUT) in a shield room.

The EUT was connected to an artificial mains network (LISN) placed on the floor.

The EUT was placed on non-metallic table 0.8 m above the metallic, grounded floor.

Amplitude measurements were performed with a quasi-peak detector and an average detector.

6.1.3 Measurement uncertainty

Conducted emission, quasi-peak detection: 1.8 dB

Conducted emission, average detection: 1.8 dB

The measurement uncertainty is given with a confidence of 95 % with the coverage factor, k = 2.

6.1.4 Test equipment used

Equipment Model Serial No. Vendor Next Cal. Date Use

Test Receiver ESPI3 101171 ROHDE &

SCHWARZ 2018.08.03 □

Test Receiver ESR7 101120 ROHDE &

SCHWARZ 2018.08.03 ■

LISN NSLK 8127 8127518 SCHWARZBECK 2018.08.04 □

Two-Line

V-Network ENV216

3560.6550.12-

101874-Rq

ROHDE &

SCHWARZ 2018.08.03 ■

ISN ISN T800 30813 TESEQ 2018.02.02 □

ISN ISN T8-Cat6 29709 TESEQ 2018.02.02 □

PULSE LIMITER ESH3-Z2 100059 ROHDE &

SCHWARZ 2018.02.02 □

KOREATÜV NORD GROUP

ReviewedSpot checkedWitnessed by AuthorizedInspector

Kim, Won-Wook

Page 9: Electromagnetic Compatibility Test Reporthanseointernational.com/wp-content/...Test-Report.pdf · Test Specification: EN 55014-1:2006 + A1 + A2:2011 EN 55014-2:1997 + A1 + A2:2008

Page: 8 of 38 Report Number: UCSCE-1708-105

발 급 번 호 : U C SKE -

UQE-TRF-01(Rev.0)

6.1.5 Test set-up photos

[Front view]

[Rear view]

KOREATÜV NORD GROUP

ReviewedSpot checkedWitnessed by AuthorizedInspector

Kim, Won-Wook

Page 10: Electromagnetic Compatibility Test Reporthanseointernational.com/wp-content/...Test-Report.pdf · Test Specification: EN 55014-1:2006 + A1 + A2:2011 EN 55014-2:1997 + A1 + A2:2008

Page: 9 of 38 Report Number: UCSCE-1708-105

발 급 번 호 : U C SKE -

UQE-TRF-01(Rev.0)

6.1.6 Test data

- Frequency range : 150 kHz ~ 30 MHz

- Bandwidth : 9 kHz

[Quasi-Peak]

Frequency

[MHz]

LISN

[dB]

Cable Loss

[dB]

Line

[H/N]

Limit

[dBμV]

Reading

[dBμV]

Results

[dBμV]

Margin

[dB]

0.16 9.93 0.15 N 65.46 21.00 31.08 -34.38

0.26 9.71 0.15 N 61.43 18.54 28.40 -33.03

0.55 9.96 0.14 N 56.00 16.16 26.26 -29.74

1.00 9.79 0.16 H 56.00 10.21 20.16 -35.84

1.41 9.74 0.17 H 56.00 7.05 16.96 -39.04

2.07 9.75 0.18 N 56.00 5.18 15.11 -40.89

3.37 9.72 0.19 H 56.00 6.23 16.14 -39.86

6.02 9.78 0.22 H 60.00 6.10 16.10 -43.90

10.06 9.94 0.27 N 60.00 5.57 15.78 -44.22

22.14 10.26 0.40 H 60.00 6.93 17.59 -42.41

29.72 10.47 0.47 H 60.00 8.58 19.52 -40.48

[Average]

Frequency

[MHz]

LISN

[dB]

Cable Loss

[dB]

Line

[H/N]

Limit

[dBμV]

Reading

[dBμV]

Results

[dBμV]

Margin

[dB]

* Average mode was not recorded, because Quasi-Peak values were under the Average limit.

* Remark: “H” Hot Line, “N” Neutral Line

* Results [dBμV] = Reading [dBμV] + LISN [dB] + Cable Loss [dB]

* Margin [dB] = Results [dBμV] – Limit [dBμV]

KOREATÜV NORD GROUP

ReviewedSpot checkedWitnessed by AuthorizedInspector

Kim, Won-Wook

Page 11: Electromagnetic Compatibility Test Reporthanseointernational.com/wp-content/...Test-Report.pdf · Test Specification: EN 55014-1:2006 + A1 + A2:2011 EN 55014-2:1997 + A1 + A2:2008

Page: 10 of 38 Report Number: UCSCE-1708-105

발 급 번 호 : U C SKE -

UQE-TRF-01(Rev.0)

6.1.7 Test graph

[Hot Line]

* : Quasi-Peak, : Average

[Neutral Line]

* : Quasi-Peak, : Average

KOREATÜV NORD GROUP

ReviewedSpot checkedWitnessed by AuthorizedInspector

Kim, Won-Wook

Page 12: Electromagnetic Compatibility Test Reporthanseointernational.com/wp-content/...Test-Report.pdf · Test Specification: EN 55014-1:2006 + A1 + A2:2011 EN 55014-2:1997 + A1 + A2:2008

Page: 11 of 38 Report Number: UCSCE-1708-105

발 급 번 호 : U C SKE -

UQE-TRF-01(Rev.0)

6.2 Mains terminal discontinuous disturbance voltage

Test Standard EN 55014-1:2006/A2:2011

Tested Date 2017.08.24

Input Ratings 230 V~, 50 Hz

Temperature (25.0 ± 0.1) °C Humidity (64.35 ± 0.35) % R.H.

Test result Met / Pass

6.2.1 Test set-up and procedure

The initial test was made to count discontinuous disturbance classified as clicks (n) over the Q-Peak limits of mains

terminals disturbance voltage at each frequencies.

The test was observed for 120 min (T) for each measurement.

The click rate “N” was determined from the formula N = n * f/T.

The relevant click limit “Lq” for discontinuous disturbance was determined in according the formula given in EN

55014-1, Clause 4.2.2.2.

The second test run was made to determine how many clicks exceed the click limit “Lq” the time for this second run

was the same as the time taken for initial test.

6.2.2 Measurement uncertainty

The measurement uncertainty is 1.8 dB

The measurement uncertainty is given with a confidence of 95 % with the coverage factor, k = 2.

6.2.3 Test equipment used

Equipment Model Serial No. Vendor Next Cal. Date Use

Test Receiver ESPI3 101171 ROHDE &

SCHWARZ 2018.08.03 □

Test Receiver ESR7 101120 ROHDE &

SCHWARZ 2018.08.03 □

EMI Receiver 9010 274WX90601 PMM 2018.08.03 ■

LISN NSLK 8127 8127518 SCHWARZBECK 2018.08.04 □

Two-Line

V-Network ENV216

3560.6550.12-

101874-Rq

ROHDE &

SCHWARZ 2018.08.03 ■

KOREATÜV NORD GROUP

ReviewedSpot checkedWitnessed by AuthorizedInspector

Kim, Won-Wook

Page 13: Electromagnetic Compatibility Test Reporthanseointernational.com/wp-content/...Test-Report.pdf · Test Specification: EN 55014-1:2006 + A1 + A2:2011 EN 55014-2:1997 + A1 + A2:2008

Page: 12 of 38 Report Number: UCSCE-1708-105

발 급 번 호 : U C SKE -

UQE-TRF-01(Rev.0)

6.2.4 Test set-up photos

6.2.5 Test data

- Observation time: 120 min

Frequency 150 kHz 500 kHz 1.4 MHz 30 MHz

Continuous Limit, L 66 56 56 60

Click rate, N - - - -

Click level*, Lc - - - -

Click limit, Lq =

Lc + L - - - -

Counted clicks

exceeding the click

limit (Number)

- - - -

Test result Pass Pass Pass Pass

* The discontinuous disturbance noise was not observed during the test. * Conducted disturbance test was tested Hot Line of worst between Hot Line and Neutral Line

KOREATÜV NORD GROUP

ReviewedSpot checkedWitnessed by AuthorizedInspector

Kim, Won-Wook

Page 14: Electromagnetic Compatibility Test Reporthanseointernational.com/wp-content/...Test-Report.pdf · Test Specification: EN 55014-1:2006 + A1 + A2:2011 EN 55014-2:1997 + A1 + A2:2008

Page: 13 of 38 Report Number: UCSCE-1708-105

발 급 번 호 : U C SKE -

UQE-TRF-01(Rev.0)

6.3 Radiated disturbance

Test Standard EN 55014-1:2006/A2:2011

Tested Date 2017.08.24

Input Ratings 230 V~, 50 Hz

Temperature (30.4 ± 0.1) °C Humidity (59.15 ± 0.05) % R.H.

Test result Met / Pass

6.3.1 Limit

Frequency [MHz] Limit [dBμV/m] @ 10 m

30 ~ 230 30

230 ~ 1 000 37

6.3.2 Test set-up and procedure

A pretest was performed at 3 m distance in a semi-anechoic chamber for searching correct frequency.

The final test was done at a 10 m open area test site with a quasi-peak detector.

EUT was placed on a non-metallic table height of 0.8 m above the reference ground plane.

Cables were folded back and forth forming a bundle 0.3 m to 0.4 m long and were hanged at a 0.4 m height to the

ground plane.

Cables connected to EUT were fixed to cause maximum emission. Test was made with the antenna positioned in both

the horizontal and vertical planes of polarization.

The measurement antenna was varied in height above the conducting ground plane to obtain the maximum signal

strength.

6.3.3 Measurement uncertainty

Radiated emission electric field intensity, 30 MHz ~ 1 000 MHz: 4.0 dB

The measurement uncertainty is given with a confidence of 95 % with the coverage factor, k = 2.

6.3.4 Test equipment used

Equipment Model Serial No. Vendor Next Cal. Date Use

Test Receiver ESPI3 101171 ROHDE &

SCHWARZ 2018.08.03 ■

Test Receiver ESR7 101120 ROHDE &

SCHWARZ 2018.08.03 □

BI-LOG ANT VULB 9163 691 SCHWARZBECK 2018.03.11 ■

Antenna Master act-a400 20090812002 Audix Coporation - ■

Turn Table act-t450 2009814072 Audix Coporation - ■

AMPLIFIER 310N 291723 SONOMA 2018.08.03 ■

Controller act CT-0131 Audix Coporation - ■

KOREATÜV NORD GROUP

ReviewedSpot checkedWitnessed by AuthorizedInspector

Kim, Won-Wook

Page 15: Electromagnetic Compatibility Test Reporthanseointernational.com/wp-content/...Test-Report.pdf · Test Specification: EN 55014-1:2006 + A1 + A2:2011 EN 55014-2:1997 + A1 + A2:2008

Page: 14 of 38 Report Number: UCSCE-1708-105

발 급 번 호 : U C SKE -

UQE-TRF-01(Rev.0)

6.3.5 Test set-up photos

[Front view]

[Rear view]

KOREATÜV NORD GROUP

ReviewedSpot checkedWitnessed by AuthorizedInspector

Kim, Won-Wook

Page 16: Electromagnetic Compatibility Test Reporthanseointernational.com/wp-content/...Test-Report.pdf · Test Specification: EN 55014-1:2006 + A1 + A2:2011 EN 55014-2:1997 + A1 + A2:2008

Page: 15 of 38 Report Number: UCSCE-1708-105

발 급 번 호 : U C SKE -

UQE-TRF-01(Rev.0)

6.3.6 Test data

- Frequency range : 30 MHz ~ 1 000 MHz

- Bandwidth : 120 kHz

- Distance : 10 m

Frequency

[MHz]

Reading

[dBμV]

Antenna

Polarity

[H/V]

Height

[m]

Antenna

Factor

[dB/m]

Cable

Loss

[dB]

Amp.

Gain

[dB]

Results

[dBμV/m]

Limit

[dBμV/m]

Margin

[dB]

39.53 41.20 V 1.00 12.14 2.20 31.70 23.84 30.00 -6.16

44.68 36.70 V 1.00 13.20 2.35 31.70 20.55 30.00 -9.45

67.88 40.10 V 1.00 9.43 3.12 31.68 20.97 30.00 -9.03

112.13 33.60 V 1.00 10.56 4.08 31.65 16.59 30.00 -13.41

122.86 34.40 V 1.00 9.77 4.29 31.64 16.82 30.00 -13.18

231.76 29.40 V 1.00 11.88 6.14 31.56 15.86 37.00 -21.14

* Remark: “H” Horizontal, “V” Vertical

* Results [dBμV/m] = Reading [dBμV] + Antenna Factor [dB/m] + Cable Loss [dB] – Amp. Gain [dB]

* Margin [dB] = Results [dBμV/m] – Limit [dBμV/m]

KOREATÜV NORD GROUP

ReviewedSpot checkedWitnessed by AuthorizedInspector

Kim, Won-Wook

Page 17: Electromagnetic Compatibility Test Reporthanseointernational.com/wp-content/...Test-Report.pdf · Test Specification: EN 55014-1:2006 + A1 + A2:2011 EN 55014-2:1997 + A1 + A2:2008

Page: 16 of 38 Report Number: UCSCE-1708-105

발 급 번 호 : U C SKE -

UQE-TRF-01(Rev.0)

6.4 Harmonics current emissions

Test Standard EN 61000-3-2:2014

Tested Date 2017.08.24

Input Ratings 230 V~, 50 Hz

Temperature (25.35 ± 0.05) °C Humidity 56.8 % R.H.

Test result Met Class A / Pass

6.4.1 Test setup and procedure The equipment is supplied in series with shunt(s) Rms or current transformer(s) from a source having the same

Nominal voltage and frequency as the rated supply voltage and frequency of the Measurements shall be made under

Normal load, or conditions for adequate heat discharge, and underequipment.

Normal operating conditions. User’s operation controls or automatic programmers shall be set to produce the

maximum harmonic component, for each successive harmonic component in turn. For the purpose of harmonic

current limitation, equipment is classified as follows:

Class A : Equipment not specified in one of the three other Classes shall be considered as Class A equipment.

- Balanced three-phase equipment;

- Household appliances, excluding equipment identified as class D;

- Tools, excluding portable tools;

- Dimmers for incandescent lamps;

- Audio equipment.

Class B:

- portable tools;

- arc welding equipment which is not professional equipment.

Class C:

- lighting equipment.

Class D: Equipment having a specified power according to 6.2.2 less than or equal to 600 W, of the following types:

- personal computers and personal computer monitors;

- television receivers.

- refrigerators and freezers having one or more variable-speed drives to control compressor motor(s).

6.4.2 Measurement uncertainty

The uncertainty of our equipments for harmonic measurement is 0.2 %.

The measurement uncertainty is given with a confidence of 95 % with the coverage factor, k = 2.

6.4.3 Test equipment used

Equipment Model Serial No. Vendor Next Cal. Date Use

Hamonics/Flicker 5001IX-208-

150/300 S59160 C.I. 2018.08.03 ■

KOREATÜV NORD GROUP

ReviewedSpot checkedWitnessed by AuthorizedInspector

Kim, Won-Wook

Page 18: Electromagnetic Compatibility Test Reporthanseointernational.com/wp-content/...Test-Report.pdf · Test Specification: EN 55014-1:2006 + A1 + A2:2011 EN 55014-2:1997 + A1 + A2:2008

Page: 17 of 38 Report Number: UCSCE-1708-105

발 급 번 호 : U C SKE -

UQE-TRF-01(Rev.0)

6.4.4 Test set-up photos

KOREATÜV NORD GROUP

ReviewedSpot checkedWitnessed by AuthorizedInspector

Kim, Won-Wook

Page 19: Electromagnetic Compatibility Test Reporthanseointernational.com/wp-content/...Test-Report.pdf · Test Specification: EN 55014-1:2006 + A1 + A2:2011 EN 55014-2:1997 + A1 + A2:2008

Page: 18 of 38 Report Number: UCSCE-1708-105

발 급 번 호 : U C SKE -

UQE-TRF-01(Rev.0)

6.4.5 Test data

KOREATÜV NORD GROUP

ReviewedSpot checkedWitnessed by AuthorizedInspector

Kim, Won-Wook

Page 20: Electromagnetic Compatibility Test Reporthanseointernational.com/wp-content/...Test-Report.pdf · Test Specification: EN 55014-1:2006 + A1 + A2:2011 EN 55014-2:1997 + A1 + A2:2008

Page: 19 of 38 Report Number: UCSCE-1708-105

발 급 번 호 : U C SKE -

UQE-TRF-01(Rev.0)

KOREATÜV NORD GROUP

ReviewedSpot checkedWitnessed by AuthorizedInspector

Kim, Won-Wook

Page 21: Electromagnetic Compatibility Test Reporthanseointernational.com/wp-content/...Test-Report.pdf · Test Specification: EN 55014-1:2006 + A1 + A2:2011 EN 55014-2:1997 + A1 + A2:2008

Page: 20 of 38 Report Number: UCSCE-1708-105

발 급 번 호 : U C SKE -

UQE-TRF-01(Rev.0)

KOREATÜV NORD GROUP

ReviewedSpot checkedWitnessed by AuthorizedInspector

Kim, Won-Wook

Page 22: Electromagnetic Compatibility Test Reporthanseointernational.com/wp-content/...Test-Report.pdf · Test Specification: EN 55014-1:2006 + A1 + A2:2011 EN 55014-2:1997 + A1 + A2:2008

Page: 21 of 38 Report Number: UCSCE-1708-105

발 급 번 호 : U C SKE -

UQE-TRF-01(Rev.0)

6.5 Voltage changes, Voltage fluctuations and flicker

Test Standard EN 61000-3-3:2013

Tested Date 2017.08.24

Input Ratings 230 V~, 50 Hz

Temperature 25.4 °C Humidity 56.7 % R.H.

Test result Met / Pass

6.5.1 Test set-up and procedure

EUT was connected to the power analyzer system.

Measurement was performed to obtain the desired flicker parameters.

The measuring time depends on which parameters are to be measured.

Plt = 2 h

Pst = 10 min

Controls and automatic programs shall be set to produce the most unfavorable sequence of voltage changes, using

only those combinations of controls and programs are mentioned by the manufacturer in the instruction manual.

6.5.2 Measurement uncertainty

The uncertainty of our equipment for flicker measurement is 5 %.

The measurement uncertainty is given with a confidence of 95 % with the coverage factor, k = 2.

6.5.3 Test equipment used

Equipment Model Serial No. Vendor Next Cal. Date Use

Hamonics/Flicker 5001IX-208-

150/300 S59160 C.I. 2018.08.03 ■

6.5.4 Test set-up photos

KOREATÜV NORD GROUP

ReviewedSpot checkedWitnessed by AuthorizedInspector

Kim, Won-Wook

Page 23: Electromagnetic Compatibility Test Reporthanseointernational.com/wp-content/...Test-Report.pdf · Test Specification: EN 55014-1:2006 + A1 + A2:2011 EN 55014-2:1997 + A1 + A2:2008

Page: 22 of 38 Report Number: UCSCE-1708-105

발 급 번 호 : U C SKE -

UQE-TRF-01(Rev.0)

6.5.5 Test data

KOREATÜV NORD GROUP

ReviewedSpot checkedWitnessed by AuthorizedInspector

Kim, Won-Wook

Page 24: Electromagnetic Compatibility Test Reporthanseointernational.com/wp-content/...Test-Report.pdf · Test Specification: EN 55014-1:2006 + A1 + A2:2011 EN 55014-2:1997 + A1 + A2:2008

Page: 23 of 38 Report Number: UCSCE-1708-105

발 급 번 호 : U C SKE -

UQE-TRF-01(Rev.0)

6.6 Electrostatic discharge

Test Standard EN 61000-4-2:1995+A1:1998+A2:2000, Criteria: B

Test Level Contact/VCP/HCP: ± 4 kV

Air: ± 8 kV

Discharge Impedance 330 Ω / 150 pF

Test Time at least 10 times for each adapting point

Tested Date 2017.08.24

Input Ratings 230 V~, 50 Hz

Temperature 26.1 °C Humidity 40.3 % R.H.

Atmospheric pressure 100.4 kPa

Test Result Met criterion A / Pass

6.6.1 Test set-up and procedure

A ground reference plane was located on the floor, and connected to earth via a low Impedance connection.

The return cable of the ESD generator was connected to the reference plane.

In case of floor standing equipment, EUT was placed on the reference plane on 0.1 m of insulating Support.

In case of table top equipment, EUT was placed on a wooden table 0.8 m above the reference grounded floor.

A horizontal coupling plane (HCP) was placed on the table, and Connected to the reference plane via a 470 kohm

resistor located in each end (0.5 mm insulating support between EUT and HCP).

In both cases a vertical coupling plane (VCP) of 0.5 m x 0.5 m was located 0.1 m from the EUT’s sides.

The VCP was connected to the reference plane in the same matter as the HCP.

6.6.2 Measurement uncertainty

It has been demonstrated that the ESD generator meets the specified requirements in the standard with at least a 95 %

confidence.

6.6.3 Test equipment used

Equipment Model Serial No. Vendor Next Cal. Date Use

ESD Simulator ESS-2000 4010C63927 NoiseKen 2018.08.07 ■

HAEFELY TEST

AG ONYX 16 177897

HAEFELY

TECHNOLOGY 2018.02.03 □

HCP - - - - ■

VCP - - - - ■

KOREATÜV NORD GROUP

ReviewedSpot checkedWitnessed by AuthorizedInspector

Kim, Won-Wook

Page 25: Electromagnetic Compatibility Test Reporthanseointernational.com/wp-content/...Test-Report.pdf · Test Specification: EN 55014-1:2006 + A1 + A2:2011 EN 55014-2:1997 + A1 + A2:2008

Page: 24 of 38 Report Number: UCSCE-1708-105

발 급 번 호 : U C SKE -

UQE-TRF-01(Rev.0)

6.6.4 Test set-up photos

6.6.5 Test data

Location Applied Level (±) Criteria Results

VCP 4 kV B A

HCP 4 kV B A

* There was no deviation from normal operation condition during and after the test..

Location (EUT) Applied Level (±) Method Criteria Results

(1) Pedal switch Metal, Screw Part 4 kV Contact B A

(2) Control box screw, Metal Part 4 kV Contact B A

(3) AC/DC Adapter, Pedal switch,

Control box cover Part 8 kV Air B A

* There was no deviation from normal operation condition during and after the test..

KOREATÜV NORD GROUP

ReviewedSpot checkedWitnessed by AuthorizedInspector

Kim, Won-Wook

Page 26: Electromagnetic Compatibility Test Reporthanseointernational.com/wp-content/...Test-Report.pdf · Test Specification: EN 55014-1:2006 + A1 + A2:2011 EN 55014-2:1997 + A1 + A2:2008

Page: 25 of 38 Report Number: UCSCE-1708-105

발 급 번 호 : U C SKE -

UQE-TRF-01(Rev.0)

6.6.6 ESD points

1 3

3

2

3

1

3 2

KOREATÜV NORD GROUP

ReviewedSpot checkedWitnessed by AuthorizedInspector

Kim, Won-Wook

Page 27: Electromagnetic Compatibility Test Reporthanseointernational.com/wp-content/...Test-Report.pdf · Test Specification: EN 55014-1:2006 + A1 + A2:2011 EN 55014-2:1997 + A1 + A2:2008

Page: 26 of 38 Report Number: UCSCE-1708-105

발 급 번 호 : U C SKE -

UQE-TRF-01(Rev.0)

6.7 Electric fast transient/burst immunity

Test Standard EN 61000-4-4:2004, Criteria: B

Coupling Coupling Decoupling Network

Test Level AC Mains: ± 1 kV

Repetition Freq. 5 kHz, Tr / Th = 5 / 50 ns

Coupling Time 120 s

Tested Date 2017.08.25

Input Ratings 230 V~, 50 Hz

Temperature 25.9 °C Humidity 45.0 % R.H.

Atmospheric pressure 100.8 kPa

Test Result Met criterion A / Pass

6.7.1 Test set-up and procedure

A ground reference plane was located on the floor.

EFT generator was connected to reference ground plane via low impedance connection.

For floor standing equipment, EUT was placed on a 0.1 m wooden table.

For tabletop equipment, EUT was placed on a 0.1 m above the ground reference plane.

Test generator and coupling/decoupling network was placed on, and bounded to, the ground reference plane.

When using the coupling clamp, the minimum distance between the coupling plates and all other conductive surfaces,

except the ground reference plane beneath the coupling clamp, Shall be 0.5 m.

6.7.2 Measurement uncertainty

It has been demonstrated that the EFT/Burst generator meets the specified requirements in the standard with at least a

95 % confidence.

6.7.3 Test equipment used

Equipment Model Serial No. Vendor Next Cal. Date Use

EMC IMMUNITY

TEST EMCPRO PLUS 0906221

ThermoFisher

Scientific 2018.08.03 □

Capacitive Clamp CCL 0904227 ThermoFisher

Scientific 2018.08.03 □

COMPACT

IMMUNITY

TEST SYSTEM

AXOS5 180998 HAEFELY EMC

TECHNOLOGY 2018.02.02 ■

THREE PHASES

EXTERNAL CDN FP-COMB32 181211

HAEFELY EMC

TECHNOLOGY 2018.02.02 □

Capacitive

Coupling Clamp IP4B 181514

HAEFELY EMC

TECHNOLOGY 2018.02.02 □

KOREATÜV NORD GROUP

ReviewedSpot checkedWitnessed by AuthorizedInspector

Kim, Won-Wook

Page 28: Electromagnetic Compatibility Test Reporthanseointernational.com/wp-content/...Test-Report.pdf · Test Specification: EN 55014-1:2006 + A1 + A2:2011 EN 55014-2:1997 + A1 + A2:2008

Page: 27 of 38 Report Number: UCSCE-1708-105

발 급 번 호 : U C SKE -

UQE-TRF-01(Rev.0)

6.7.4 Test set-up photos

6.7.5 Test data

EFT Coupling Point Level (±) Criteria Results

L 1 kV B A

N 1 kV B A

L - N 1 kV B A

* There was no deviation from normal operation condition during and after the test.

KOREATÜV NORD GROUP

ReviewedSpot checkedWitnessed by AuthorizedInspector

Kim, Won-Wook

Page 29: Electromagnetic Compatibility Test Reporthanseointernational.com/wp-content/...Test-Report.pdf · Test Specification: EN 55014-1:2006 + A1 + A2:2011 EN 55014-2:1997 + A1 + A2:2008

Page: 28 of 38 Report Number: UCSCE-1708-105

발 급 번 호 : U C SKE -

UQE-TRF-01(Rev.0)

6.8 Surge immunity

Test Standard EN 61000-4-5:2005, Criteria: B

Coupling Coupling Decoupling Network

Test Level AC Mains (Line to Line): ± 1 kV

Angles 90°, 270°

Number of surge/time 1 time / 1 min, total 5 times

Repetition rate 60 s

Tested Date 2017.08.25

Input Ratings 230 V~, 50 Hz

Temperature (26.0 ± 0.1) °C Humidity (44.6 ± 0.2) % R.H.

Atmospheric pressure 100.8 kPa

Test Result Met criterion A / Pass

6.8.1 Test set-up and procedure

A ground reference plane was located on the floor. SURGE generator was connected to reference ground plane via

low impedance connection. For floor standing equipment, EUT was placed on a 0.1 m wooden table.

For table top equipment, EUT was placed on a wooden table (0.1 m) above the reference plane.

6.8.2 Measurement uncertainty

It has been demonstrated that the surge tester meets the specified requirements in the standard with at least a 95 %

confidence

6.8.3 Test equipment used

Equipment Model Serial No. Vendor Next Cal. Date Use

EMC IMMUNITY

TEST EMCPRO PLUS 0906221

ThermoFisher

Scientific 2018.08.03 □

I/O Lin

Coupler/Decoupler CM-I/OCD 0906226

ThermoFisher

Scientific - □

Telecom

coupler/Decoupler CM-TELCD 0905226

ThermoFisher

Scientific - □

COMPACT

IMMUNITY TEST

SYSTEM

AXOS5 180998 HAEFELY EMC

TECHNOLOGY 2018.02.02 ■

THREE PHASES

EXTERNAL CDN FP-COMB32 181211

HAEFELY EMC

TECHNOLOGY 2018.02.02 □

KOREATÜV NORD GROUP

ReviewedSpot checkedWitnessed by AuthorizedInspector

Kim, Won-Wook

Page 30: Electromagnetic Compatibility Test Reporthanseointernational.com/wp-content/...Test-Report.pdf · Test Specification: EN 55014-1:2006 + A1 + A2:2011 EN 55014-2:1997 + A1 + A2:2008

Page: 29 of 38 Report Number: UCSCE-1708-105

발 급 번 호 : U C SKE -

UQE-TRF-01(Rev.0)

6.8.4 Test set-up photos

6.8.5 Test data

Coupling Point Level (±) Criteria Results

L to N 1 kV B A

* There was no deviation from normal operation condition during and after the test.

KOREATÜV NORD GROUP

ReviewedSpot checkedWitnessed by AuthorizedInspector

Kim, Won-Wook

Page 31: Electromagnetic Compatibility Test Reporthanseointernational.com/wp-content/...Test-Report.pdf · Test Specification: EN 55014-1:2006 + A1 + A2:2011 EN 55014-2:1997 + A1 + A2:2008

Page: 30 of 38 Report Number: UCSCE-1708-105

발 급 번 호 : U C SKE -

UQE-TRF-01(Rev.0)

6.9 Conducted disturbance induced by RF fields immunity

Test Standard EN 61000-4-6:2003+A1:2004+A2:2006, Criteria: A

Tested Frequency 150 kHz ~ 230 MHz

Test Level/Modulation 3 V (AM 80 %, 1 kHz)

Coupling Method AC Mains: M2

Dwell Time 1 s

Step Size log 1 % step

Tested Date 2017.08.25

Input Ratings 230 V~, 50 Hz

Temperature (26.8 ± 0.2) °C Humidity (42.15 ± 0.15) % R.H.

Atmospheric pressure 100.7 kPa

Test Result Met criterion A / Pass

6.9.1 Test set-up and procedure

A ground reference plane was located on the floor. The test was performed on a ground reference plane on a 0.1 m

wooden table. This test were performed using CDN for mains, clamp for signal and injection probe. The frequency

range was swept from 150 kHz to 230 MHz. This frequency range was modulated with 1 kHz sine wave at 80 %.

The signal generators provided the modulated frequency at a 1 % step size. The power and all network cable, I/O

cables longer than 3 m length were tested.

6.9.2 Measurement uncertainty

The measurement uncertainty is 2.3 dB

The measurement uncertainty is given with a confidence of 95 % with the coverage factor, k = 2.

6.9.3 Test equipment used

Equipment Model Serial No. Vendor Next Cal. Date Use

CDN M2 FCC-801-M2-16A 091165 FCC 2018.08.03 ■

CDN M3 FCC-801-M3-16A 091994 FCC 2018.08.03 □

EM INJECTION

CLAMP F-203I-23mm 091199 FCC 2018.08.07 □

Continuous Wave

Simulator CWS 500N1 P1247105423 EM Test 2018.02.02 ■

Coaxial Fixed

Attenuator ATT6/75 P1306112966 EM Test 2018.02.02 ■ KOREATÜV NORD GROUP

ReviewedSpot checkedWitnessed by AuthorizedInspector

Kim, Won-Wook

Page 32: Electromagnetic Compatibility Test Reporthanseointernational.com/wp-content/...Test-Report.pdf · Test Specification: EN 55014-1:2006 + A1 + A2:2011 EN 55014-2:1997 + A1 + A2:2008

Page: 31 of 38 Report Number: UCSCE-1708-105

발 급 번 호 : U C SKE -

UQE-TRF-01(Rev.0)

6.9.4 Test set-up photos

6.9.5 Test data

Coupling Point Coupling Method Criteria Results

AC Mains CDN (M2) A A

* There was no deviation from normal operation condition during and after the test.

KOREATÜV NORD GROUP

ReviewedSpot checkedWitnessed by AuthorizedInspector

Kim, Won-Wook

Page 33: Electromagnetic Compatibility Test Reporthanseointernational.com/wp-content/...Test-Report.pdf · Test Specification: EN 55014-1:2006 + A1 + A2:2011 EN 55014-2:1997 + A1 + A2:2008

Page: 32 of 38 Report Number: UCSCE-1708-105

발 급 번 호 : U C SKE -

UQE-TRF-01(Rev.0)

6.10 Voltage dips and short interruptions

Test Standard EN 61000-4-11:2004, Criteria: C

Number of reduction 3 T

Duration 10 s

Tested Date 2017.08.25

Input Ratings 230 V~, 50 Hz

Temperature (26.15 ± 0.05) °C Humidity 44.3 % R.H.

Atmospheric pressure 100.8 kPa

Test result Met criterion A / Pass

6.10.1 Test set-up and procedure

The dips/interruption test is only applicable to AC mains.

The dips/interruptions were applied at zero crossing.

6.10.2 Measurement uncertainty

It has been demonstrated that the voltage dips and interruptions generator meets the specified requirements in the

standard with at least a 95 % confidence

6.10.3 Test equipment used

Equipment Model Serial No. Vendor Next Cal. Date Use

EMC IMMUNITY

TEST EMCPRO PLUS 0906221

ThermoFisher

Scientific 2018.08.03 □

COMPACT

IMMUNITY

TEST SYSTEM

AXOS5 & DIP

116 180998

HAEFELY EMC

TECHNOLOGY 2018.02.02 ■

KOREATÜV NORD GROUP

ReviewedSpot checkedWitnessed by AuthorizedInspector

Kim, Won-Wook

Page 34: Electromagnetic Compatibility Test Reporthanseointernational.com/wp-content/...Test-Report.pdf · Test Specification: EN 55014-1:2006 + A1 + A2:2011 EN 55014-2:1997 + A1 + A2:2008

Page: 33 of 38 Report Number: UCSCE-1708-105

발 급 번 호 : U C SKE -

UQE-TRF-01(Rev.0)

6.10.4 Test set-up photos

6.10.5 Test data

Test Test Level

(% UT) Durations Criteria Results

Voltage dips

0 % 0.5 C A

40 % 10 C A

70 % 25 C A

* There was no deviation from normal operation condition during and after the test.

KOREATÜV NORD GROUP

ReviewedSpot checkedWitnessed by AuthorizedInspector

Kim, Won-Wook

Page 35: Electromagnetic Compatibility Test Reporthanseointernational.com/wp-content/...Test-Report.pdf · Test Specification: EN 55014-1:2006 + A1 + A2:2011 EN 55014-2:1997 + A1 + A2:2008

Page: 34 of 38 Report Number: UCSCE-1708-105

발 급 번 호 : U C SKE -

UQE-TRF-01(Rev.0)

7. EUT Photos

7.1 External view

[Front view]

[Rear view]

KOREATÜV NORD GROUP

ReviewedSpot checkedWitnessed by AuthorizedInspector

Kim, Won-Wook

Page 36: Electromagnetic Compatibility Test Reporthanseointernational.com/wp-content/...Test-Report.pdf · Test Specification: EN 55014-1:2006 + A1 + A2:2011 EN 55014-2:1997 + A1 + A2:2008

Page: 35 of 38 Report Number: UCSCE-1708-105

발 급 번 호 : U C SKE -

UQE-TRF-01(Rev.0)

[AC/DC Adapter front view]

[AC/DC Adapter rear view]

KOREATÜV NORD GROUP

ReviewedSpot checkedWitnessed by AuthorizedInspector

Kim, Won-Wook

Page 37: Electromagnetic Compatibility Test Reporthanseointernational.com/wp-content/...Test-Report.pdf · Test Specification: EN 55014-1:2006 + A1 + A2:2011 EN 55014-2:1997 + A1 + A2:2008

Page: 36 of 38 Report Number: UCSCE-1708-105

발 급 번 호 : U C SKE -

UQE-TRF-01(Rev.0)

7.2 Internal view

KOREATÜV NORD GROUP

ReviewedSpot checkedWitnessed by AuthorizedInspector

Kim, Won-Wook

Page 38: Electromagnetic Compatibility Test Reporthanseointernational.com/wp-content/...Test-Report.pdf · Test Specification: EN 55014-1:2006 + A1 + A2:2011 EN 55014-2:1997 + A1 + A2:2008

Page: 37 of 38 Report Number: UCSCE-1708-105

발 급 번 호 : U C SKE -

UQE-TRF-01(Rev.0)

7.3 Internal board view

KOREATÜV NORD GROUP

ReviewedSpot checkedWitnessed by AuthorizedInspector

Kim, Won-Wook

Page 39: Electromagnetic Compatibility Test Reporthanseointernational.com/wp-content/...Test-Report.pdf · Test Specification: EN 55014-1:2006 + A1 + A2:2011 EN 55014-2:1997 + A1 + A2:2008

Page: 38 of 38 Report Number: UCSCE-1708-105

발 급 번 호 : U C SKE -

UQE-TRF-01(Rev.0)

KOREATÜV NORD GROUP

ReviewedSpot checkedWitnessed by AuthorizedInspector

Kim, Won-Wook