McDONALD’S ORDER HERE CANOPY - NO COD NOTICE: IF PERSONA DOES NOT COORDINATE INSTALLATION, PERSONA CAN NOT BE HELD RESPONSIBLE FOR ANY VIOLATIONS OF THE SPECIFICATIONS SET FORTH IN THIS DOCUMENT. THIS DOCUMENT IS FOR BIDDING PURPOSES ONLY. EXACT INSTALLATION PROCEDURES MAY VARY BASED ON SITE SPECIFIC CONDITIONS. ANCHOR BOLT MOUNTING DETAIL (FIG. 1) 9’-4” 7’-10” PAVEMENT 1” X 48” ANCHOR BOLTS (QTY 4) ELECTRICAL CONDUIT REAR PANELS REMOVABLE FOR ACCESS 7’-0” ANCHOR BOLT DETAIL McDONALD’S VARIOUS 1-21-15 ORDER HERE CANOPY - NO COD - INSTALLATION - 150 MPH CM File Name: Prepared By: Date: Customer: Location: Note: Color output may not be exact when viewing or printing this drawing. All colors used are PMS or the closest CMYK equivalent. If these colors are incorrect, please provide the correct PMS match and a revision to this drawing will be made. Page 1 OF 3 Rev 3 700 21st Street Southwest PO Box 210 Watertown, SD 57201-0210 1 (800) 843-9888 • www.persona-inc.com DISTRIBUTED BY SIGN UP COMPANY ELEVATION: 48 11’2 3/8” Any modifications to base plates, anchor bolts, or any other structural elements must be approved by a registered structural engineer and documented on a stamped print 8” X 1/4” SQUARE TUBE REMOVABLE PANEL IN CANOPY BOTTOM FOR ACCESS TO LAMPS INSTALL LAMPS INSTALL LETTERS INSTALL SWING ARM (USE PROVIDED STAR WASHERS) ORDER HERE CANOPY INSTALLATION INSTRUCTIONS: 1. General contractor to stake sign location(s), establish final grade requirements and determine the sign orientation on the property, prior to excavation. 2. General contractor to excavate canopy foundations, set anchor bolts and conduit per template included with plate & bolt kit. Pour concrete according to engineered drawing specifications . (see note) 3. Uncrate and inspect all sign display components. Notify Persona of any damage. 4. Place leveling nuts & plate washers on anchor bolts and level (see anchor bolt detail on pg 2) temporarily for final adjustment later. 5. Remove back service panel on bottom section of pole cover. Trim the electrical conduit provided in the foundation to a length that does not interfere with routing wires into a 2X4 primary power junction box. 7. Lift vertical column structure over anchor bolts. Install plate washers and nuts over anchor bolts. Double check and adjust for level in all directions using leveling nuts. Tighten all nuts above base plate. Remove lifting provisions from column. 7. Pull primary electrical wires into junction box.. 8. Remove access cover from top of break-away clearance arm to expose hinged mounting location. Attachment hardware package can be found inside arm access cover. Hoist arm into position using straps, scissor lift or manually (note: minimum of two people necessary to attach arm). 9. Line up arm with vertical column mounting holes. Support weight of arm while attaching bolts with star washers until arm has been leveled and all 5 mounting bolts are firmly tightened against structural tube. If additional adjustments are necessary to level the arm, loosen the 5 bolts in the vertical structural tube & the 5 bolts in the hinge mechanism (located inside the arm access cover). Check for level, adjust accordingly. Torque all swing arm bolts to 80 ft/lbs of pressure (5 bolts into structural tube and 5 bolts in hinge mechanism). 10. Check arm motion and spring tension by rotating the arm and to establish smooth arm operation. Simulate motion by rotating arm approximately 12-16 inches and releasing it to return back to its stationary position against column. Note: tension springs are pre-set and should not need adjustment. Contact Persona with issues or concerns. Check for a minimum of 9’0” clearance height from bottom of swing arm to pavement. 11. Position and mount “Order Here” letters 16” from right arm edge, and 1 ½” from front of arm . Install letters on top of arm using 1/4” x 20 x 1 ½” long non- (see letter positioning detail, pg 2) corrosive bolts with nuts & washers (bolts to be provided by installer); note: nuts & washers to be on bottom side of cover. Re-install access cover to top of swing arm. 12. Lift canopy roof above column/cladding assembly, drop electrical wires through column and secure canopy to top of column with supplied bolts. Make necessary electrical connections at base of column. 13. Install (4) 48” fluorescent lamps (packaged separately) into canopy fixtures. If authorized to do so, make final electrical connections to primary power at base of sign. Test fire for illumination. Replace back service panel. 14. Remove lifting provisions from top of canopy. Seal holes with clear silicone to ensure a watertight seal. Install pre-painted yellow bolts (Persona supplied). 15. Touch up any paint on sign, bolts or structure as required. 16. Clean area. Remove excess soil & discard installation debris off-premise. NOTE: REFERENCE ENGINEERED DRAWING ON PAGE 3 FOR DETAILS: 2" MAX: REFERENCE ENGINEERED DRAWING REMOVE LIFTING PROVISIONS & SEAL HOLES WITH PRE-PAINTED BOLTS & CLEAR SILICONE

Upload: haanh

Post on 01-Jul-2018

215 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ELEVATION: 48 2. ). 9’-4” - Sign Company | Commercial … Thru... · 2015-04-30 · ANCHOR BOLTS (QTY 4) ELECTRICAL CONDUIT ... Any modifications to base plates, anchor bolts,

McDONALD’S ORDER HERE CANOPY - NO CODNOTICE:

IF PERSONA DOES NOT COORDINATE INSTALLATION, PERSONA CAN NOT BE

HELD RESPONSIBLE FOR ANY VIOLATIONS OF THE SPECIFICATIONS

SET FORTH IN THIS DOCUMENT.THIS DOCUMENT IS FOR BIDDING PURPOSES ONLY. EXACT INSTALLATION PROCEDURES MAY VARY BASED ON SITE SPECIFIC CONDITIONS.

ANCHOR BOLT MOUNTING DETAIL(FIG. 1)

9’-4”

7’-10”

PAVEMENT

1” X 48”ANCHOR BOLTS(QTY 4)

ELECTRICAL CONDUIT

REAR PANELSREMOVABLE FOR ACCESS

7’-0”

ANCHOR BOLT DETAIL

McDONALD’S

VARIOUS

1-21-15

ORDER HERE CANOPY - NO COD - INSTALLATION - 150 MPH

CMFile Name:

Prepared By:Date:Customer:

Location:

Note: Color output may not be exact when viewing or printing this drawing. All colors used are PMS or the closest CMYKequivalent. If these colors are incorrect, please provide the correct PMS match and a revision to this drawing will be made.

Page

1 OF 3Rev

3

700 21st Street SouthwestPO Box 210Watertown, SD 57201-02101 (800) 843-9888 • www.persona-inc.com

DISTRIBUTED BY SIGN UP COMPANY

ELEVATION: 48

11’2 3/8”

Any modifications to base plates, anchor bolts, or any other structural elements must be approved by a registered structural engineer and documented on

a stamped print

8” X 1/4” SQUARE TUBE

REMOVABLEPANEL IN CANOPY

BOTTOM FOR ACCESS TO LAMPS

INSTALL LAMPS INSTALL LETTERS

INSTALLSWING ARM(USE PROVIDEDSTAR WASHERS)

ORDER HERE CANOPY INSTALLATION INSTRUCTIONS:

1. General contractor to stake sign location(s), establish final grade requirements and determine the sign orientation on the property, prior to excavation.2. General contractor to excavate canopy foundations, set anchor bolts and conduit per template included with plate & bolt kit. Pour concrete according to engineered drawing specifications .(see note)3. Uncrate and inspect all sign display components. Notify Persona of any damage.4. Place leveling nuts & plate washers on anchor bolts and level (see anchor bolt detail on pg 2) temporarily for final adjustment later.5. Remove back service panel on bottom section of pole cover. Trim the electrical conduit provided in the foundation to a length that does not interfere with routing wires into a 2X4 primary power junction box.7. Lift vertical column structure over anchor bolts. Install plate washers and nuts over anchor bolts. Double check and adjust for level in all directions using leveling nuts. Tighten all nuts above base plate. Remove lifting provisions from column.7. Pull primary electrical wires into junction box..8. Remove access cover from top of break-away clearance arm to expose hinged mounting location. Attachment hardware package can be found inside arm access cover. Hoist arm into position using straps, scissor lift or manually (note: minimum of two people necessary to attach arm). 9. Line up arm with vertical column mounting holes. Support weight of arm while attaching bolts with star washers until arm has been leveled and all 5 mounting bolts are firmly tightened against structural tube. If additional adjustments are necessary to level the arm, loosen the 5 bolts in the vertical structural tube & the 5 bolts in the hinge mechanism (located inside the arm access cover). Check for level, adjust accordingly. Torque all swing arm bolts to 80 ft/lbs of pressure (5 bolts into structural tube and 5 bolts in hinge mechanism).10. Check arm motion and spring tension by rotating the arm and to establish smooth arm operation. Simulate motion by rotating arm approximately 12-16 inches and releasing it to return back to its stationary position against column. Note: tension springs are pre-set and should not need adjustment. Contact Persona with issues or concerns. Check for a minimum of 9’0” clearance height from bottom of swing arm to pavement.11. Position and mount “Order Here” letters 16” from right arm edge, and 1 ½” from front of arm . Install letters on top of arm using 1/4” x 20 x 1 ½” long non-(see letter positioning detail, pg 2) corrosive bolts with nuts & washers (bolts to be provided by installer); note: nuts & washers to be on bottom side of cover. Re-install access cover to top of swing arm. 12. Lift canopy roof above column/cladding assembly, drop electrical wires through column and secure canopy to top of column with supplied bolts. Make necessary electrical connections at base of column.13. Install (4) 48” fluorescent lamps (packaged separately) into canopy fixtures. If authorized to do so, make final electrical connections to primary power at base of sign. Test fire for illumination. Replace back service panel.14. Remove lifting provisions from top of canopy. Seal holes with clear silicone to ensure a watertight seal. Install pre-painted yellow bolts (Persona supplied).15. Touch up any paint on sign, bolts or structure as required.16. Clean area. Remove excess soil & discard installation debris off-premise.

NOTE: REFERENCE ENGINEERED DRAWING ON PAGE 3FOR DETAILS:

2" MAX: REFERENCE ENGINEERED DRAWING

REMOVE LIFTING PROVISIONS & SEAL

HOLES WITH PRE-PAINTED BOLTS & CLEAR SILICONE

Page 2: ELEVATION: 48 2. ). 9’-4” - Sign Company | Commercial … Thru... · 2015-04-30 · ANCHOR BOLTS (QTY 4) ELECTRICAL CONDUIT ... Any modifications to base plates, anchor bolts,

**NOTE: ALL PLATE WASHERS, NUTS, & LOCK NUTS TO REMAIN ON BOLTS DURING INSTALLATION OF FOUNDATION TO AVOID BEING MISPLACED ON THE JOB SITE

NOTICE:IF PERSONA DOES NOT COORDINATE INSTALLATION, PERSONA CAN NOT BE

HELD RESPONSIBLE FOR ANY VIOLATIONS OF THE SPECIFICATIONS

SET FORTH IN THIS DOCUMENT.THIS DOCUMENT IS FOR BIDDING PURPOSES ONLY. EXACT INSTALLATION PROCEDURES MAY VARY BASED ON SITE SPECIFIC CONDITIONS.

This sign is intended to be installed in accordance with the requirements of article 600 of the National Electrical Code and / or applicable local codes.This includes proper grounding and bonding of the sign.

ELECTRICAL SPECIFICATIONS:1. ILLUMINATION: COOL WHITE FLUORESCENT LAMPS2. POWER SUPPLY: (1) ELECTRONIC BALLAST3. LOAD: CANOPY: 1.90AMPS 4. CIRCUITS: (1) 20 AMP - 120 VOLT 1 1/4” THICK

1 3/8” SLOTTED HOLES1” BOLTS

5” ELECTRICAL HOLE

BASE PLATE DETAIL

18”

28”

11”

11”

ANCHOR BOLT DETAIL

CONCRETEFOOTING

DOUBLE NUT

1” Ø GALVANIZED ANCHOR BOLT

48” LONG W/ 7” THREAD @ TOP & 2 ½” THREAD @ BOTTOM; 5 NUTS &

3 PLATE WASHERS PER BOLT DOUBLE NUT

& PLATE WASHER

LEVELING NUTAND PLATE WASHER

BASE PLATE

PLATE WASHER

FRONT VIEW

LETTER POSITIONING DETAIL PROFILE VIEW

16”

1 ½”

6”

PLATE: 16

McDONALD’S ORDER HERE CANOPY - NO COD

McDONALD’S

VARIOUS

1-21-15

ORDER HERE CANOPY - NO COD - INSTALLATION - 150 MPH

CMFile Name:

Prepared By:Date:Customer:

Location:

Note: Color output may not be exact when viewing or printing this drawing. All colors used are PMS or the closest CMYKequivalent. If these colors are incorrect, please provide the correct PMS match and a revision to this drawing will be made.

Page

2 OF 3Rev

3

700 21st Street SouthwestPO Box 210Watertown, SD 57201-02101 (800) 843-9888 • www.persona-inc.com

DISTRIBUTED BY SIGN UP COMPANY

Page 3: ELEVATION: 48 2. ). 9’-4” - Sign Company | Commercial … Thru... · 2015-04-30 · ANCHOR BOLTS (QTY 4) ELECTRICAL CONDUIT ... Any modifications to base plates, anchor bolts,

ORDER HERE CANOPY - NO COD - INSTALLATION - 150 MPH0 MPHFile Name:Page

3 OF 3Rev10