elevator sump pump kits · elevator sump pump kits oil smart - staying dry and protecting the...

4
Elevator Sump Pump Kits OIL SMART - Staying dry and protecting the environment FEATURES • Protects environment from hazardous waste • The solid state device senses between oil and water • Only operates pump if water is sensed by probes. Does not operate if oil is sensed by probes. The Oil Smart kits consist of panel, oil smart switch, liquid smart alarm sensor and pump. The setup allows water to be pumped from elevator sumps and transformer vaults without danger of pumping oil into sewers and waterways.

Upload: others

Post on 23-Mar-2020

74 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Elevator Sump Pump Kits · Elevator Sump Pump Kits OIL SMART - Staying dry and protecting the environment FEATURES • Protects environment from hazardous waste • The solid state

Elevator Sump Pump KitsOIL SMART - Staying dry and protecting the environment

FEATURES

• Protects environment from hazardous waste

• The solid state device senses between oil and water

• Only operates pump if water is sensed by probes.

Does not operate if oil is sensed by probes.

The Oil Smart kits consist of panel, oil smart switch, liquid smart alarm sensor and pump. The setup allows water to be pumped from elevator sumps and transformer vaults without danger of pumping oil into sewers and waterways.

Page 2: Elevator Sump Pump Kits · Elevator Sump Pump Kits OIL SMART - Staying dry and protecting the environment FEATURES • Protects environment from hazardous waste • The solid state

9080706050403020100 100 1100

10

20

30

60

50

80

70

40

SIZE: 3/4" SOLIDS

3/4 HP

1 HP

5 FT

5 GPM

1/2 HP

1/3 HP

GPM

FEET

TOTA

L D

YN

AM

IC H

EA

D

CAPACITY

ELEVATOR PUMP KITS

FEATURES FOR PUMP

• Effluent, 1⁄3, ½, ¾ and 1 HP, single phase pump • Hard faced seal • Cast iron construction

• Effluent, ½, ¾ and 1 HP, three phase pump

Brands Model Number Electrical PanelOil Smart

SwitchLiquid Smart

Sensor Pump

B&G

ELKT2EC0311L 1/3 HP 1/60/115

A1SEE1

Included Included

2EC0311L

ELKT2EC0511 1/2 HP 1/60/115 2EC0511

ELKT2EC0512 1/2 HP 1/60/230 2EC0512

ELKT2EC0712 3/4 HP 1/60/230 2EC0712

ELKT2EC1012 1 HP 1/60/230 2EC1012

ELKT2EC0538 1/2 HP 3/60/200 A3SEE14063 2EC0538

ELKT2EC0532 1/2 HP 3/60/230 A3SEE12540 2EC0532

ELKT2EC0534 1/2 HP 3/60/460 A3SEE11625 2EC0534

ELKT2EC0738 3/4 HP 3/60/200 A3SEE16010 2EC0738

ELKT2EC0732 3/4 HP 3/60/230 A3SEE14063 2EC0732

ELKT2EC0734 3/4 HP 3/60/460 A3SEE12540 2EC0734

ELKT2EC1038 1 HP 3/60/200 A3SEE16010 2EC1038

ELKT2EC1032 1 HP 3/60/230 A3SEE16010 2EC1032

ELKT2EC1034 1 HP 3/60/460 A3SEE14063 2EC1034

PAGE 2

WastewaterBell & Gossett

Page 3: Elevator Sump Pump Kits · Elevator Sump Pump Kits OIL SMART - Staying dry and protecting the environment FEATURES • Protects environment from hazardous waste • The solid state

PANEL LAYOUTS

SIMPLEX SINGLE PHASE PANEL — A1SEE1

Enclosure Dimensions (in inches)

Wiring Diagram

ALARM TERMINAL PUMP TERMINAL

GROUND LUG

INSIDE VIEW

12

0V

RE

LAY

ALARM TERMINAL

1 2 3 4 5 6 7 8 9 10 11

BLU

ER

ED

WH

ITE

GR

EE

NB

LAN

KPH

ASE

NE

UTR

AL

WA

TER

CO

MM

ON

OIL

ALA

RM

PUMP TERMINAL

LIQUID SMARTALARM SWITCH 120 V* DRY

CONTACTS

1 2 3 4 5 6 7 8

120 V PUMP OIL SMARTSWITCH

PHA

SE

NE

UTR

AL

T1 T2 BR

OW

NB

LAC

KW

HIT

E

ALARM TERMINAL PUMP TERMINAL

GROUND LUG

INSIDE VIEW

12

0V

RE

LAY

ALARM TERMINAL

1 2 3 4 5 6 7 8 9 10 11

BLU

ER

ED

WH

ITE

GR

EE

NB

LAN

KPH

ASE

NE

UTR

AL

WA

TER

CO

MM

ON

OIL

ALA

RM

PUMP TERMINAL

LIQUID SMARTALARM SWITCH 120 V* DRY

CONTACTS

1 2 3 4 5 6 7 8

120 V PUMP OIL SMARTSWITCH

PHA

SE

NE

UTR

AL

T1 T2 BR

OW

NB

LAC

KW

HIT

E

ALARM TERMINAL PUMP TERMINAL

GROUND LUG

INSIDE VIEW

12

0V

RE

LAY

ALARM TERMINAL

1 2 3 4 5 6 7 8 9 10 11

BLU

ER

ED

WH

ITE

GR

EE

NB

LAN

KPH

ASE

NE

UTR

AL

WA

TER

CO

MM

ON

OIL

ALA

RM

PUMP TERMINAL

LIQUID SMARTALARM SWITCH 120 V* DRY

CONTACTS

1 2 3 4 5 6 7 8

120 V PUMP OIL SMARTSWITCH

PHA

SE

NE

UTR

AL

T1 T2 BR

OW

NB

LAC

KW

HIT

E

*

* Hook up separate 120V supply here or jump from pump terminal 1 and 3 to alarm terminal 6 and 7 for power.

* For 240V, remove jumper and supply power to terminals 1 and 2, with neutral on 3.

PAGE 3PAGE 3

WastewaterBell & Gossett

Page 4: Elevator Sump Pump Kits · Elevator Sump Pump Kits OIL SMART - Staying dry and protecting the environment FEATURES • Protects environment from hazardous waste • The solid state

TERMINAL 1

TERMINAL 1

PHA

SE

NE

UTR

AL

BLU

E

RE

D

WH

ITE

GR

EE

N

GR

EE

N

RE

D

WH

ITE

BLA

NK

BLA

NK

BLA

NK

LIQUID SMARTSWITCH

PUMP

T1 T2 T3

optionaloverload

protection

TER

MIN

AL

2

TERMINAL 3

MAINDISCONNECT TERMINAL 3

OIL SMARTSWITCH

120VPRE-WIRED

BYFACTORY

TER

MIN

AL

2

PUMP - LEAK/SEAL FAILURE

COM

BLANK

COM

COM

COM

PUMP FAULTS

WATER

OIL

HIGH LIQUID

COM

MO

TOR

SEA

L /O

THE

R SIG

NA

LTE

RM

INA

LS

PUM

P FAILU

RE

DR

Y C

ON

TAC

TH

IGH

LIQU

ID A

LAR

MD

RY

CO

NTA

CTS

MAINDISCONNECT

480VAC

L1 L2 L3

Bell & Gossett is a trademark of Xylem Inc. or one of its subsidiaries.© 2017 Xylem Inc. BGOILSMSALES R4 July 2017

Xylem Inc.2881 East Bayard Street Ext., Suite ASeneca Falls, NY 13148Phone: (866) 325-4210Fax: (888) 322-5877www.bellgossett.com

PANEL LAYOUTS

SIMPLEX THREE PHASE PANEL — A3SEE1

Enclosure Dimensions (in inches)

TERMINAL 1

TERMINAL 1

PHA

SE

NE

UTR

AL

BLU

E

RE

D

WH

ITE

GR

EE

N

GR

EE

N

RE

D

WH

ITE

BLA

NK

BLA

NK

BLA

NK

LIQUID SMARTSWITCH

PUMP

T1 T2 T3

optionaloverload

protection

TER

MIN

AL

2

TERMINAL 3

MAINDISCONNECT TERMINAL 3

OIL SMARTSWITCH

120VPRE-WIRED

BYFACTORY

TER

MIN

AL

2

PUMP - LEAK/SEAL FAILURE

COM

BLANK

COM

COM

COM

PUMP FAULTS

WATER

OIL

HIGH LIQUID

COM

MO

TOR

SEA

L /O

THE

R SIG

NA

LTE

RM

INA

LS

PUM

P FAILU

RE

DR

Y C

ON

TAC

TH

IGH

LIQU

ID A

LAR

MD

RY

CO

NTA

CTS

MAINDISCONNECT

480VAC

L1 L2 L3

Wiring Diagram

Wiring Diagram

TERMINAL 1

TERMINAL 1

PHA

SE

NE

UTR

AL

BLU

E

RE

D

WH

ITE

GR

EE

N

GR

EE

N

RE

D

WH

ITE

BLA

NK

BLA

NK

BLA

NK

LIQUID SMARTSWITCH

PUMP

T1 T2 T3

optionaloverload

protection

TER

MIN

AL

2

TERMINAL 3

MAINDISCONNECT TERMINAL 3

OIL SMARTSWITCH

120VPRE-WIRED

BYFACTORY

TER

MIN

AL

2

PUMP - LEAK/SEAL FAILURE

COM

BLANK

COM

COM

COM

PUMP FAULTS

WATER

OIL

HIGH LIQUID

COM

MO

TOR

SEA

L /O

THE

R SIG

NA

LTE

RM

INA

LS

PUM

P FAILU

RE

DR

Y C

ON

TAC

TH

IGH

LIQU

ID A

LAR

MD

RY

CO

NTA

CTS

MAINDISCONNECT

480VAC

L1 L2 L3

TERMINAL 1

TERMINAL 1PH

ASE

NE

UTR

AL

BLU

E

RE

D

WH

ITE

GR

EE

N

GR

EE

N

RE

D

WH

ITE

BLA

NK

BLA

NK

BLA

NK

LIQUID SMARTSWITCH

PUMP

T1 T2 T3optionaloverload

protection

TER

MIN

AL

2

TERMINAL 3

MAINDISCONNECT TERMINAL 3

OIL SMARTSWITCH

120VPRE-WIRED

BYFACTORY

TER

MIN

AL

2

PUMP - LEAK/SEAL FAILURE

COM

BLANK

COM

COM

COM

PUMP FAULTS

WATER

OIL

HIGH LIQUID

COM

MO

TOR

SEA

L /O

THE

R SIG

NA

LTE

RM

INA

LS

PUM

P FAILU

RE

DR

Y C

ON

TAC

TH

IGH

LIQU

ID A

LAR

MD

RY

CO

NTA

CTS

MAINDISCONNECT

480VAC

L1 L2 L3

TERMINAL 1

TERMINAL 1

PHA

SE

NE

UTR

AL

BLU

E

RE

D

WH

ITE

GR

EE

N

GR

EE

N

RE

D

WH

ITE

BLA

NK

BLA

NK

BLA

NK

LIQUID SMARTSWITCH

PUMP

T1 T2 T3

optionaloverload

protection

TER

MIN

AL

2

TERMINAL 3

MAINDISCONNECT TERMINAL 3

OIL SMARTSWITCH

120VPRE-WIRED

BYFACTORY

TER

MIN

AL

2

PUMP - LEAK/SEAL FAILURE

COM

BLANK

COM

COM

COM

PUMP FAULTS

WATER

OIL

HIGH LIQUID

COM

MO

TOR

SEA

L /O

THE

R SIG

NA

LTE

RM

INA

LS

PUM

P FAILU

RE

DR

Y C

ON

TAC

TH

IGH

LIQU

ID A

LAR

MD

RY

CO

NTA

CTS

MAINDISCONNECT

480VAC

L1 L2 L3

WastewaterBell & Gossett