elisa brio 2

2
ReiGed Diagnostics ReiGed Diagnostics : www.ReiGed-Diagnostics.com [email protected] [email protected] Brio 2 Brio 2 NEW BRIO TOTALLY WALK AWAY Automatic open system to any ELISA 96 well microplate testing. The work plan allows to choose the best configuration for the laboratory needs, and offers the possibility to modify the configuration of the samples and reagents racks up to 120 samples. The reaction tray, fitting two independent microplates, is able to incubate and shake them with different times and incubation modes, from 25°C to 40°C, or at room temperature, to effect 192 determinations. With these two different incubation modes, the system constitutes the ideal support for test-runs (6 tests on line and 90 samples; 2 tests on line and 120 samples), thus offering fast and excellent performances. The internal independent reading station allows faster attainments on simultaneous tests. The Internal Personal Computer with management software is extremely advanced (Windows ’XP), easy to use and allows: - to optimize the time of each single test (T.M.S.: Time Management System); - automated error recovery; - curve storage, whereby a new curve can be calculated by using only two calibrators; - Historical Patients Record, with statistical evaluation of results; - quality control program; - Multifunctional arm (dispensing needle, washing manifold and microplate movement pliers); - Dilution unit with two precision syringes, capacity 1000 and 2500μL; - Original double needle washing system (internal and external) able to prevent from any risk of contamination; - Automated microplate washing system working with a 16-needles manifold (8 aspirating and 8 dispensing needles). The highly sophisticated electronic and mechanic technology, and the new compact design, make of Brio 2 an ideal and complete instrument.

Upload: gerobag

Post on 18-Jul-2015

1.515 views

Category:

Health & Medicine


4 download

TRANSCRIPT

Page 1: Elisa Brio 2

ReiGedDiagnostics

ReiGed Diagnostics :[email protected] [email protected]

Brio 2

Brio 2NEW BRIO TOTALLY WALK AWAYAutomatic open system to any ELISA 96 well microplate testing. The work plan allows to choose the best configuration for the laboratory needs, and offers the possibility to modify the configuration of the samples and reagents racks up to 120 samples. The reaction tray, fitting two independent microplates, is able toincubate and shake them with different times and incubation modes, from 25°C to 40°C, or at room temperature,to effect 192 determinations. With these two different incubation modes, the system constitutes the ideal support for test-runs (6 tests on line and 90 samples; 2 tests on line and 120 samples), thus offering fast and excellent performances. The internal independent reading station allows faster attainments on simultaneous tests.The Internal Personal Computer with management software is extremely advanced (Windows ’XP), easy to use and allows:- to optimize the time of each single test (T.M.S.: Time Management System);- automated error recovery;- curve storage, whereby a new curve can be calculated by using only two calibrators;- Historical Patients Record, with statistical evaluation of results;- quality control program;- Multifunctional arm (dispensing needle, washing manifold and microplate movement pliers);- Dilution unit with two precision syringes, capacity 1000 and 2500µL;- Original double needle washing system (internal and external) able to prevent from any risk of contamination;- Automated microplate washing system working with a 16-needlesmanifold (8 aspirating and 8 dispensing needles).The highly sophisticated electronic and mechanic technology, andthe new compact design, make of Brio 2 an ideal and completeinstrument.

Page 2: Elisa Brio 2

ReiGedDiagnostics

ReiGed Diagnostics :[email protected] [email protected]

TECHNICAL CHARACTERISTICS

Preparator:

Dispensing speed : serum: 400 samples/h with 500 ul of �ush solution –

reagent: 800 wells/h in multidispensing.

Volume :tnegaer – lu 1 fo spets htiw lu 003-01 elpmas :

10-300 ul with steps of 1 ul.

Precision ;)007.0=.D.O( lu 01 htiw 0.3 <% VC :elpmas :

- reagent CV%<3 with 100 ul.

Carry-over mpp1 <: tnegaer – 6-01x.1( mpp1 < :elpmas :

(1x10-6);

Level sensor ytilibissop htiw ytivitisnes lu 051 ,eviticapac :

to detect liquid contact.

Mixer .)xam( mpr 0031 :

Incubation .C°04 ot pu :

Washer .dlofinam lennahc laixaoc 8 :

Optical system:

Wavelengths nerefretni htiW .mn 026-055-294-054-504 :

tial �lters

Reading range : 0-3000 O.D. monochromatic and dichroma

tic – 0-9000 O .D. in polychromatic.

Resolution .D.O 100.0 :

Precision at 405 nm : CV%<3.0

Light sour ce: 20W halogen lamp

Optical sensor : 8 solid state photodiodes

Oper ative conditions : 15 – 32 °C (in function)

Safety standards : CEI EN 61010-1; Class 1 Installation II; CE

marking

Power supply zH 06-05 )CAV511tseuqer nopu( 032 :

Power absorbance : 1200VA (instrument + auxiliary services)

Dimensions : L. 111 cm x P . 60 cm x H. 44 cm

eight: 85 Kg