emc poweredge management pack for dell - vmware

58
Management Pack for Dell EMC PowerEdge VMware vRealize True Visibility Suite 1.0

Upload: others

Post on 15-May-2022

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: EMC PowerEdge Management Pack for Dell - VMware

Management Pack for Dell EMC PowerEdge

VMware vRealize True Visibility Suite 1.0

Page 2: EMC PowerEdge Management Pack for Dell - VMware

You can find the most up-to-date technical documentation on the VMware website at:

https://docs.vmware.com/

VMware, Inc.3401 Hillview Ave.Palo Alto, CA 94304www.vmware.com

Copyright ©

2020 VMware, Inc. All rights reserved. Copyright and trademark information.

Management Pack for Dell EMC PowerEdge

VMware, Inc. 2

Page 3: EMC PowerEdge Management Pack for Dell - VMware

Contents

1 Management Pack for Dell EMC PowerEdge 4

2 Getting Started (Dell EMC PowerEdge) 6

3 System Requirements (Dell EMC PowerEdge) 7

4 Installing the Management Pack (Dell EMC PowerEdge) 9

5 Configuring the Management Pack (Dell EMC PowerEdge) 12Creating a Credential (Dell EMC PowerEdge) 12

Creating an Adapter Instance (Dell EMC PowerEdge) 17

Configuring the Properties File (Dell EMC PowerEdge) 21

Validating Data Collection (Dell EMC PowerEdge) 22

6 Troubleshooting the Management Pack (Dell EMC PowerEdge) 24

7 Using the Management Pack (Dell EMC PowerEdge) 27Resource Kinds and Relationships (Dell EMC PowerEdge) 27

Inventory Tree (Traversal Spec) (Dell EMC PowerEdge) 30

Dashboards (Dell EMC PowerEdge) 33

Dell EMC PowerEdge Health 34

Dell EMC PowerEdge Overview 34

Dell EMC PowerEdge Virtual Machine Workbench 35

Dell EMC VxRail Clusters 36

Dell EMC VxRail Overview 37

Reports (Dell EMC PowerEdge) 38

Alerts (Dell EMC PowerEdge) 39

Metrics (Dell EMC PowerEdge) 44

VMware, Inc. 3

Page 4: EMC PowerEdge Management Pack for Dell - VMware

Management Pack for Dell EMC PowerEdge 1The VMware vRealize® True Visibility™ Management Pack for Dell EMC PowerEdge is an embedded adapter for vRealize Operations (vROps), collecting performance data from your Dell EMC VxRail or PowerEdge systems and providing predictive analysis and real-time information about problems in your infrastructure—all within the vRealize Operations user interface.

Notable Features

The Management Pack for Dell EMC VxRail and PowerEdge provides the following notable features:

n 5 comprehensive monitoring dashboards:

n Dell EMC PowerEdge – Overview, Health, and Virtual Machine Workbench

n Dell EMC VxRail – Overview and Clusters

n 3 exportable reports,including health and availability information, Blade/Rack server KPIs, and firmware details

n 300+ collected metricsfor Dell EMC VxRail/ PowerEdge resources

n 130+ detailed alerts and recommendations imported from VxRail/PowerEdge

n Key performance metrics such as server-level percentages denoting the overall health of child resources such as power supplies and cooling devices, average physical disk capacity, and cumulative power usage

n External relationshipsfrom VxRail Cluster to Blade/Rack server to ESXi host

Getting Started

Wondering where to start? See our Chapter 2 Getting Started (Dell EMC PowerEdge) and Chapter 3 System Requirements (Dell EMC PowerEdge) topics for details.

Release Notes

Version Release Date Description

3.0.0 October 6, 2020 Initial General Availability release for VMware vRealize® True Visibility™

VMware, Inc. 4

Page 5: EMC PowerEdge Management Pack for Dell - VMware

Known Issues/Limitations

n The default JVM configuration used by the vROps collector can cause issues with larger environments and/or multiple adapter instances for SNMP-based management packs. See the following VMware knowledge base article for Increasing the Max UDP Sockets in a VMware vRealize Operations Manager server for assistance.

n To obtain cluster resources, management pack users configuring for VxRail must also install and configure the Management Pack for vSAN on their vROps system.

n In order to retrieve alerts that are triggered directly by iDRAC/SNMP, the adapter instance must use SNMP v3.

Management Pack for Dell EMC PowerEdge

VMware, Inc. 5

Page 6: EMC PowerEdge Management Pack for Dell - VMware

Getting Started (Dell EMC PowerEdge) 2This topic explains how the Management Pack for Dell EMC PowerEdge works and how to get started using it.

How the Management Pack Works

The Management Pack for Dell EMC PowerEdge uses the Simple Network Management Protocol (SNMP) to access your cluster/server's Integrated Dell Remote Access Controller (iDRAC) and imports critical monitoring data such as resources, relationships, metrics, and alerts into vRealize Operations Manager.

This management pack works in conjunction with the Management Pack for vSAN to discover and create VXRail Cluster resources. To obtain cluster resources, management pack users must also have the vSAN MP installed and configured, and if a Blade/Rack server is related to a VMWare Host system, which is related to a VMware vSAN Cluster, the cluster resource will be created.

How to Get Started

To get started monitoring VxRail and PowerEdge from within vRealize Operations, see the following topics:

1 Review the System Requirements (Dell EMC PowerEdge) and have the following information available:

n Management IP for your cluster/server's iDRAC

n SNMPv2c or v3 credentials

n vSphere credentials (to create relationships to the ESXi host)

2 Install the management pack. See: Chapter 4 Installing the Management Pack (Dell EMC PowerEdge).

3 Configure the management pack. See: Chapter 5 Configuring the Management Pack (Dell EMC PowerEdge). If you encounter any Test Connection errors when configuring, see: Chapter 6 Troubleshooting the Management Pack (Dell EMC PowerEdge).

4 Start using the management pack. See: Chapter 7 Using the Management Pack (Dell EMC PowerEdge).

VMware, Inc. 6

Page 7: EMC PowerEdge Management Pack for Dell - VMware

System Requirements (Dell EMC PowerEdge) 3Before installing and configuring the Management Pack, ensure your system meets the following requirements:

vRealize Operations Requirements

Dell EMC VxRail and PowerEdge Requirements

Version(s) vRealize Operations 7.x & 8.x (Standard, Advanced, or Enterprise editions)

Important To obtain cluster resources, management pack users configuring for VxRail must also install and configure the Management Pack for vSAN on their vROps system.

Hardware: The Management Pack supports the following R-, M-, and T-series generation Dell EMC server types:

n 12g

n 13g

n 14g

iDRAC Firmware: Servers must be equipped with iDRAC v7+ with firmware version 1.30.30+.

Important SNMPv2c or SNMPv3 must be configured on all Dell EMC servers.

VMware, Inc. 7

Page 8: EMC PowerEdge Management Pack for Dell - VMware

Connection iDRAC hostname or IP address.

Important If the address of your Chassis Monitoring Console (CMC)is different than that of your iDRAC, you must list it in addition to your iDRAC if you wish for the Management Pack to return chassis metrics. See Creating an Adapter Instance (Dell EMC PowerEdge).

The Management Pack collects data via SNMPv2c or SNMPv3 via default port 161.

Important See Creating an Adapter Instance (Dell EMC PowerEdge) for information on supported host formats.

Credentials SNMPv2c read-only community string -or- SNMPv3 User Name and Password

Important The Management Pack requires a least-privileged SNMP user account of read-only.

Important In order to retrieve alerts that are triggered directly by iDRAC/SNMP, the adapter instance must use SNMP v3.

Important vCenter credentials are required to create relationships to the ESXi host. To make the relationships between the monitored cluster/server and the ESXi host attached to it, the management pack must query the vSphere server API. To do this, configure the management pack with vCenter hostname and the credentials of a user with permissions to the hosts in vCenter. We recommend using the same credentials set as the VROps vSphere adapter for consistency.

Management Pack for Dell EMC PowerEdge

VMware, Inc. 8

Page 9: EMC PowerEdge Management Pack for Dell - VMware

Installing the Management Pack (Dell EMC PowerEdge) 4This Management Pack is installed using a .pak file.

Procedure

1 Log in to vRealize Operations as an admin user.

2 From the top navigation bar, select Administration. In the left panel, the default Solutions

view will be selected. In the right panel, click the Add icon.

Note If you are using vROps 7.5, Solutions will have two subcategories: Configuration and Repository. Select Repository and scroll down to Other Management Packs and select Add a Management Pack to install a new management pack. Refer to the second screenshot below if needed.

vROps versions 7 and lower:

vROps version 7.5:

VMware, Inc. 9

Page 10: EMC PowerEdge Management Pack for Dell - VMware

3 The Add Solution window will appear. Browse to the location of the saved .pak file, then click Upload.

Management Pack for Dell EMC PowerEdge

VMware, Inc. 10

Page 11: EMC PowerEdge Management Pack for Dell - VMware

4 Click Next when the upload has finished.

5 Read and accept the End User License Agreement (EULA), then click Next.

6 Click Finish when the installation process is complete.

Important The installation utility creates a specific adapter folder and.jar file in the $VCOPS_BASE/user/plugins/inbound folder.

Management Pack for Dell EMC PowerEdge

VMware, Inc. 11

Page 12: EMC PowerEdge Management Pack for Dell - VMware

Configuring the Management Pack (Dell EMC PowerEdge) 5Configuring the Management Pack for Dell EMC PowerEdge in vRealize Operations includes the following required tasks:

n Creating a Credential (Dell EMC PowerEdge)

n Creating an Adapter Instance (Dell EMC PowerEdge)

Caution The default JVM configuration used by the vROps collector can cause issues with larger environments and/or multiple adapter instances for SNMP-based management packs. See the following VMware knowledge base article for Increasing the Max UDP Sockets in a VMware vRealize Operations Manager server for assistance.

Note In addition, you may want to perform one or more of the following optional tasks to further configure the Management Pack for your specific needs:

n Configuring the Properties File (Dell EMC PowerEdge) (optional)

n Validating Data Collection (Dell EMC PowerEdge) (optional)

This chapter includes the following topics:

n Creating a Credential (Dell EMC PowerEdge)

n Creating an Adapter Instance (Dell EMC PowerEdge)

n Configuring the Properties File (Dell EMC PowerEdge)

n Validating Data Collection (Dell EMC PowerEdge)

Creating a Credential (Dell EMC PowerEdge)

One of the required configuration tasks for the Management Pack is to create a set of credentials in vROps.

Prerequisites

n Chapter 4 Installing the Management Pack (Dell EMC PowerEdge)

VMware, Inc. 12

Page 13: EMC PowerEdge Management Pack for Dell - VMware

Procedure

1 From the top navigation bar, select Administration. In the left panel, expand the Management category and select Credentials.

Management Pack for Dell EMC PowerEdge

VMware, Inc. 13

Page 14: EMC PowerEdge Management Pack for Dell - VMware

2 Click the Add icon. In the Manage Credential window that appears, select your credential Kind:

Important Each Credential Kind has the option to include vSphere credentials, which are required to make relationships to the ESXi host. To do this, configure the management pack with vCenter hostname and the credentials of a user with permissions to the hosts in vCenter. We recommend using the same credentials set as the vROps vSphere adapter for consistency.

SNMP v2 Credentials

n Credential name

n Community String (read-only)

n vSphere Host

n vSphere Username

n vSphere Password

SNMP v3 Credentials (Auth Priv)

Management Pack for Dell EMC PowerEdge

VMware, Inc. 14

Page 15: EMC PowerEdge Management Pack for Dell - VMware

n Credential name

n SNMP User

n Authentication Password

n Authentication Type

n Privacy Password

n Privacy Type

n vSphere Host

n vSphere Username

n vSphere Password

SNMP v3 Credentials No Auth No Priv

Management Pack for Dell EMC PowerEdge

VMware, Inc. 15

Page 16: EMC PowerEdge Management Pack for Dell - VMware

n Credential name

n SNMP User

n vSphere Host

n vSphere Username

n vSphere Password

SNMP v3 Credentials (Auth) No Priv

Management Pack for Dell EMC PowerEdge

VMware, Inc. 16

Page 17: EMC PowerEdge Management Pack for Dell - VMware

n Credential name

n SNMP User

n Authentication Password

n Authentication Type

n vSphere Host

n vSphere Username

n vSphere Password

3 Click OK to save your credential.

What to do next

Creating an Adapter Instance (Dell EMC PowerEdge)

Creating an Adapter Instance (Dell EMC PowerEdge)

Before you can begin using the Management Pack, you must create an adapter instance to identify the host from which the Management Pack will retrieve data.

Prerequisites

n Chapter 4 Installing the Management Pack (Dell EMC PowerEdge)

n Creating a Credential (Dell EMC PowerEdge)

Management Pack for Dell EMC PowerEdge

VMware, Inc. 17

Page 18: EMC PowerEdge Management Pack for Dell - VMware

Procedure

1 From the top navigation bar, select Administration. In the right panel, the Solutions list will be displayed.

2 Select Dell EMC Compute from the Solutions list on the right.

3 Click the Configure icon. The Manage Solution window will appear.

Important Click the Add icon above the Instance Name list on the left to create multiple adapter instances.

Management Pack for Dell EMC PowerEdge

VMware, Inc. 18

Page 19: EMC PowerEdge Management Pack for Dell - VMware

4 In the Manage Solution window, enter the following information:

a Instance Settings:

n Display Name: A name for this particular instance of the Management Pack

n Description: Optional, but it can be helpful to describe multiple instances of the Management Pack.

b Basic Settings:

n Managment IP: The Management Pack supports the following host formats:

n Individual hostname or IP address (IPv4/IPv6 are supported)

n IP range (e.g., 192.168.0.32-192.168.0.67, 10.10.01.0-10.10.0.254)

NOTE:Test Connection

Management Pack for Dell EMC PowerEdge

VMware, Inc. 19

Page 20: EMC PowerEdge Management Pack for Dell - VMware

n IP CIDR notation range (e.g., 10.6.14.0/24, 2620:0:2d0:200:1f00:400::7/120)

n Any of the above in a comma-separated list

Note If the IP range for your Chassis Monitoring Console (CMC) is different than that of your iDRAC, you must list it separately here to return chassis metrics.

n Credential: Select the credential you created when Creating a Credential (Dell EMC

PowerEdge), or click the Add icon now to create one.

c Advanced Settings:

n Collectors/Groups: Default Collector/Group is automatically selected. Click the drop-down menu if you want to run the collection on a different node.

n SNMP Port: Enter the UDP port to connect to SNMP; default port is 161.

n Retries: Enter the number of times you want the adapter to retry to connect to the specified host before the SNMP request times out; default value is 2 retries.

n Timeout Interval:Enter the maximum amount of time (seconds) for the adapter to wait to timeout when trying to connect to the specified host; default value is 30 seconds.

n Socket Timeout Interval (Seconds): Specify the maximum amount of time (seconds) for the adapter to wait for an incoming socket connection; default value is 2 seconds. Note that a timeout of 0 is interpreted as an infinite timeout.

n Discovery Timeout Interval (s): Enter the maximum amount of time (seconds) to wait for discovery to complete against a given system; default value is 120 seconds.

n Collection Timeout Interval (s): Enter the maximum amount of time (seconds) to wait for collection to complete against a given system; default value is 180 seconds.

n Maximum Threads: Enter the maximum number of concurrent threads that the adapter instance can use to retrieve metrics from the specified targets; default value is 30. Note that this setting is for total synchronous SNMP calls to each server, not concurrent calls to the same server.

n Include SNMP Events (v3 only): Specify whether the adapter should pass alerts retrieved from the SNMP alert table; default value is false.

n Alert Cancel Hours: Specify the maximum age (in hours) for SNMP alerts; default value is 24 hours.

n Support Autodiscovery: Default setting is True, which allows the adapter instance to create resources for you. This should not be set to False.

Important In order to maintain a consistent collection interval of five minutes, it is recommended that an adapter instance collects on no more than 16 total blade or rack servers. For a collection interval value of ten minutes, we recommend that your adapter instance collects on no more than 32 blade/rack servers.

Management Pack for Dell EMC PowerEdge

VMware, Inc. 20

Page 21: EMC PowerEdge Management Pack for Dell - VMware

5 Click Test Connection to test the configured connection information. If you encounter any errors, see: Chapter 6 Troubleshooting the Management Pack (Dell EMC PowerEdge).

6 Click Save Settings and Close to save your adapter instance.

What to do next

n To validate data collection, see: Validating Data Collection (Dell EMC PowerEdge).

Configuring the Properties File (Dell EMC PowerEdge)

You may want to further customize your adapter instance configuration using the DellEMCCompute.properties file.

Prerequisites

n Creating an Adapter Instance (Dell EMC PowerEdge)

Properties

The following additional configuration settings can be found in the DellEmcCompute.properties file located in the $VCOPS_BASE/user/plugins/inbound/dell_emc_compute_adapter_3/conf/ folder. You can modify the entries in the file, and they will be read in during the next collection.

Name Description Default

maximum_number_of_events_to_return_per_collection Maximum number of events to return during each collections. Events will be throttled to the amount given.

relationship_sync_interval Describes how many collections are made between each collection that returns relationship data.

8

max_relationships_per_collection Maximum number of relationships to return during each collections. Relationships will be throttled to the amount given

initial_max_scripts_per_execution Maximum number of scripts run per execution initially

1000000

subsequent_max_scripts_per_execution Maximum number of scripts run per execution subsequently

100

dell_emc_compute_bm_exuno_dellcompute_amperage_probe.enabled Set to true to enable collection of this resource

false

dell_emc_compute_bm_exuno_dellcompute_chassis_power_supply.enabled Set to true to enable collection of this resource

false

Management Pack for Dell EMC PowerEdge

VMware, Inc. 21

Page 22: EMC PowerEdge Management Pack for Dell - VMware

dell_emc_compute_bm_exuno_dellcompute_cooling_device.enabled Set to true to enable collection of this resource

false

dell_emc_compute_bm_exuno_dellcompute_intrusion_probe.enabled Set to true to enable collection of this resource

false

dell_emc_compute_bm_exuno_dellcompute_memory_device.enabled Set to true to enable collection of this resource

false

dell_emc_compute_bm_exuno_dellcompute_physical_disk.enabled Set to true to enable collection of this resource

false

dell_emc_compute_bm_exuno_dellcompute_power_unit.enabled Set to true to enable collection of this resource

false

dell_emc_compute_bm_exuno_dellcompute_processor_device.enabled Set to true to enable collection of this resource

false

dell_emc_compute_bm_exuno_dellcompute_rack_power_supply.enabled Set to true to enable collection of this resource

false

dell_emc_compute_bm_exuno_dellcompute_system_battery.enabled Set to true to enable collection of this resource

false

dell_emc_compute_bm_exuno_dellcompute_temperature_probe.enabled Set to true to enable collection of this resource

false

dell_emc_compute_bm_exuno_dellcompute_virtual_disk.enabled Set to true to enable collection of this resource

false

dell_emc_compute_bm_exuno_dellcompute_voltage_probe.enabled Set to true to enable collection of this resource

false

What to do next

n To validate data collection, see: Validating Data Collection (Dell EMC PowerEdge).

Validating Data Collection (Dell EMC PowerEdge)

After you add an adapter instance, you will most likely want to validate the data that it collects in vROps. Wait until one collection cycle is complete and the Collection Status for the adapter instance on the Solutions page shows as "Data Receiving".

Prerequisites

n Creating an Adapter Instance (Dell EMC PowerEdge)

Procedure

1 From the top navigation bar, select Environment.

2 In the left panel select either the All Objects or applicable Dell EMC inventory tree, then expand the objects list.

Management Pack for Dell EMC PowerEdge

VMware, Inc. 22

Page 23: EMC PowerEdge Management Pack for Dell - VMware

3 Select a resource from the list, then click the All Metrics tab to select metrics and validate values against the data source.

What to do next

n To learn more about using the Management Pack, see: Chapter 7 Using the Management Pack (Dell EMC PowerEdge).

Management Pack for Dell EMC PowerEdge

VMware, Inc. 23

Page 24: EMC PowerEdge Management Pack for Dell - VMware

Troubleshooting the Management Pack (Dell EMC PowerEdge) 6Once you have finished Chapter 4 Installing the Management Pack (Dell EMC PowerEdge) and Chapter 5 Configuring the Management Pack (Dell EMC PowerEdge), check the Collection State and Collection Status for the adapter instance on the Solutions page. If they show as Not Collecting or No Data Receiving, respectively, the following troubleshooting topics can help you diagnose and correct common problems with your adapter instance.

Test Connection Errors

When Creating an Adapter Instance (Dell EMC PowerEdge), click Test Connection after entering all of your configuration settings to ensure vROps can connect to the specified host.

The following errors are possible:

SNMP IP Range Incorrectly Formatted

Error Message: Unable to establish a valid connection to the target system. SNMP IP range formatted incorrectly.

Description: Ensure the specified SNMP IP range is formatted correctly. The Management Pack supports the following host formats:

n Individual hostname or IP (IPv4 or IPv6)

n IP range (e.g., 192.168.0.32-192.168.0.67, 10.10.0.0-10.10.1.255)

n IP CIDR notation range (e.g., 10.6.14.0/24, 2620:0:2d0:200:1f00:400::7/120)

n Any of the above in a comma-separated list

Important If the SNMP IP range is greater than 400 IP addresses, Test Connection may fail.

Important If the IP range for your Chassis Monitoring Console (CMC) is different than that of your iDRAC, you must list it separately here to return chassis metrics.

No Server Found in SNMP IP Range

Error Message: Unable to establish a valid connection to the target system. No server found in SNMP IP range.

VMware, Inc. 24

Page 25: EMC PowerEdge Management Pack for Dell - VMware

Description: Verify the following items are configured properly:

n Ensure the server is on and configured to use SNMPv2c or SNMPv3.

n Ensure the vROps server IP has permission to access SNMP.

n Ensure the SNMP community string/username is correct.

n Ensure the management port IP is in the IP range.

No Dell EMC Server to VMware Host System Relationships Created

If relationships between your Dell EMC Server and VMware Host are not created, verify the following:

n Ensure the Fully Qualified Domain Name (FQDN) is set correctly on the iDRAC.

n Ensure vSphere credentials were provided when Creating a Credential (Dell EMC PowerEdge).

Server Rediscovery Fails

Problem: If you remove a blade or rack server from vROps and try to add it back later, the Management Pack will fail to rediscover the server.

Cause: For each adapter instance, the Management Pack stores the IP addresses of known servers in the server_ips<Adapter Resource Internal ID>.properties file found in $VCOPS_BASE/user/plugins/inbound/dell_power_edge_adapter/work/. You can find the Adapter Resource Internal ID by navigating to Inventory Explorer , selecting an adapter resource, and inspecting the Internal ID column for that resource.

If a server’s IP address is not deleted from this file when it is removed from vROps, the adapter will be unable to rediscover that server.

Solution: Delete the server’s IP address from the server_ips<Adapter Resource Internal ID>.properties file. The adapter will then be able to rediscover the server.

Important If an adapter instance is already collecting on an IP address, no other adapter instances will be able to discover that resource.

Adapter and Collector Log Files

You can review adapter errors in the adapter and collector log files, which can be viewed in the vROps UI or in an external log viewer.

n Adapter log files are located in the $VCOPS_BASE/user/log/adapters/DellEmcComputeAdapter/ folder.

n Collector log files are located in the $VCOPS_BASE/user/log/ folder.

Management Pack for Dell EMC PowerEdge

VMware, Inc. 25

Page 26: EMC PowerEdge Management Pack for Dell - VMware

To set the base log level for the collector in vROps:

1 Navigate to Administration > Logs.

2 Expand the MASTER folder, then select the COLLECTOR folder.

3 Click the Edit Properties icon.

4 In the Root logger level drop-down menu, select the desired option.

n The default logging level is warning.

n To troubleshoot issues, set the logging level to info.

n To view detailed messages, including micro steps, queries, and returned results, set the logging level to debug.

Caution If you set the logging level to debug , log files can become large very quickly. Set the logging level to debug only for short periods of time.

For more information about viewing log files and modifying levels, refer to the vROps online help.

Management Pack for Dell EMC PowerEdge

VMware, Inc. 26

Page 27: EMC PowerEdge Management Pack for Dell - VMware

Using the Management Pack (Dell EMC PowerEdge) 7The Management Pack for Dell EMC PowerEdge includes the following out-of-the-box features, harnessing the power of the vRealize Operations user interface:

n Resource Kinds and Relationships (Dell EMC PowerEdge)

n Inventory Tree (Traversal Spec) (Dell EMC PowerEdge)

n Dashboards (Dell EMC PowerEdge)

n Reports (Dell EMC PowerEdge)

n Alerts (Dell EMC PowerEdge)

n Metrics (Dell EMC PowerEdge)

This chapter includes the following topics:

n Resource Kinds and Relationships (Dell EMC PowerEdge)

n Inventory Tree (Traversal Spec) (Dell EMC PowerEdge)

n Dashboards (Dell EMC PowerEdge)

n Reports (Dell EMC PowerEdge)

n Alerts (Dell EMC PowerEdge)

n Metrics (Dell EMC PowerEdge)

Resource Kinds and Relationships (Dell EMC PowerEdge)

The Management Pack for Dell EMC PowerEdge creates Resource Kinds and Relationships (associations) for critical resources in your Dell EMC PowerEdge environment.

Resource Kinds

Performance, health, availability, and capacity data are collected for the following VxRail/PowerEdge resource kinds:

n Dell EMC Amperage Probe*

n Dell EMC Blade Server

VMware, Inc. 27

Page 28: EMC PowerEdge Management Pack for Dell - VMware

n Dell EMC Chassis

n Dell EMC Chassis Power Supply*

n Dell EMC Cluster**

n Dell EMC Cooling Device*

n Dell EMC Intrusion Probe*

n Dell EMC Memory Device*

n Dell EMC Physical Disk*

n Dell EMC Power Unit*

n Dell EMC Processor Device*

n Dell EMC Rack Power Supply*

n Dell EMC Rack Server

n Dell EMC System Battery*

n Dell EMC Temperature Probe*

n Dell EMC Virtual Disk*

n Dell EMC Voltage Probe*

Important The resource kinds marked with a single asterisk (*) are not collected by default. If you want to enable collection for these resources, you must set the applicable parameter in the DellEmcCompute.properties file to true. See: Configuring the Properties File (Dell EMC PowerEdge).

Important The VXRail Cluster resource is created in a unique way. It is created only if a Blade/Rack server is related to a VMWare Host system, which is related to a VMware vSAN Cluster resource. Again, the following relationship must exist: Blade/Rack server > Host System > vSAN Cluster.

Relationships

Relationships among discovered resources are also created by the management pack.

How Relationships are Collected

Relationships are returned to vROps during the second collection. Internal relationships are returned every collection. External relationships are re-calculated at the interval specified by the relationship_sync_interval properties in the DellEmcCompute.properties file, whose default value is 8 (i.e. recalculated in collection 2, 10, 18, etc.).

Management Pack for Dell EMC PowerEdge

VMware, Inc. 28

Page 29: EMC PowerEdge Management Pack for Dell - VMware

External relationships to VMware Host System resources are made from Blade/Rack server resources using the following methods:

1 First attempt: Matching the Blade/Rack Server's host_name metric (via vCenter) to the resource name of a VMware Host System

2 Fallback: Matching the Blade/Rack Server's fqdn metric to the resource name of a VMware Host System

Dell EMC VxRail and PowerEdge Relationships Diagram

The hierarchical structure of the Dell EMC VxRail/PowerEdge relationships is depicted in the diagram below.

External Relationships

In addition to internal relationships, the management pack also includes the following external relationships:

n VxRail Cluster > Blade/Rack Server (N/A for PowerEdge)

Management Pack for Dell EMC PowerEdge

VMware, Inc. 29

Page 30: EMC PowerEdge Management Pack for Dell - VMware

n Blade/Rack Server > VMware Host

See also:

Inventory Tree (Traversal Spec) (Dell EMC PowerEdge)

Inventory Tree (Traversal Spec) (Dell EMC PowerEdge)

The Inventory Tree (Traversal Spec) feature in vROps allows you to easily navigate your Dell EMC PowerEdge environment. The hierarchical structure implicitly shows relationships among resources and enables quick drill-downs to root-cause issues.

To access your Dell EMC Cluster (VxRail) or Dell EMC PowerEdge Inventory Tree, select Environment from the top navigation bar, then select the applicable Dell EMC inventory tree from the left panel. Click on a resource from the inventory tree to populate details about the resource in the right panel.

Management Pack for Dell EMC PowerEdge

VMware, Inc. 30

Page 31: EMC PowerEdge Management Pack for Dell - VMware

Example Inventory Tree – Dell EMC Cluster

Icon Legend

Dell EMC Amperage Probe

Dell EMC Blade Server

Dell EMC Chassis

Dell EMC Chassis Power Supply

Dell EMC Cluster

Dell EMC Cooling Device

Management Pack for Dell EMC PowerEdge

VMware, Inc. 31

Page 32: EMC PowerEdge Management Pack for Dell - VMware

Dell EMC Intrusion Probe

Dell EMC Memory Device

Dell EMC Physical Disk

Dell EMC Power Unit

Dell EMC Processor Device

Dell EMC Rack Power Supply

Management Pack for Dell EMC PowerEdge

VMware, Inc. 32

Page 33: EMC PowerEdge Management Pack for Dell - VMware

Dell EMC Rack Server

Dell EMC System Battery

Dell EMC Temperature Probe

Dell EMC Virtual Disk

Dell EMC Voltage Probe

Dashboards (Dell EMC PowerEdge)

Dashboards

Dashboards are the primary feature for monitoring and troubleshooting Dell EMC PowerEdge within vRealize Operations.

The following dashboards are included in the Management Pack for Dell EMC PowerEdge:

Management Pack for Dell EMC PowerEdge

VMware, Inc. 33

Page 34: EMC PowerEdge Management Pack for Dell - VMware

Dell EMC PowerEdge

n Dell EMC PowerEdge Health

n Dell EMC PowerEdge Overview

n Dell EMC PowerEdge Virtual Machine Workbench

Dell EMC VxRail

n Dell EMC VxRail Clusters

n Dell EMC VxRail Overview

Dell EMC PowerEdge Health

The Dell EMC PowerEdge Health dashboard is your jumping-off point for troubleshooting the health of your PowerEdge environment. Select a resource from the Environment Overview widget on the left to populate any alerts, details, and health over time for the selected resource.

Dell EMC PowerEdge Overview

Management Pack for Dell EMC PowerEdge

VMware, Inc. 34

Page 35: EMC PowerEdge Management Pack for Dell - VMware

The Dell EMC PowerEdge Overview dashboard provides at-a-glance heatmaps depicting the health of your host systems and virtual machines residing on PowerEdge, in addition to your PowerEdge resources. Select a resource on the left to populate its details on the right.

Dell EMC PowerEdge Virtual Machine Workbench

TheDell PowerEdge Virtual Machine Workbenchdashboard allows you to pinpoint performance problems originating on virtual machines. You can select a host system, server, virtual machine, and related datastore on the left to view key performance metrics displayed in sparkline graphs on the right.

Management Pack for Dell EMC PowerEdge

VMware, Inc. 35

Page 36: EMC PowerEdge Management Pack for Dell - VMware

Dell EMC VxRail Clusters

TheDell EMC VxRail Clustersdashboardprovides an in depth look at your VxRail clusters. Select a cluster instance to populate top alerts rolled up from child resources, a graph depicting the alert volume over time, cluster status, and related server, host system, and vSAN cluster KPIs to help enable troubleshooting.

Management Pack for Dell EMC PowerEdge

VMware, Inc. 36

Page 37: EMC PowerEdge Management Pack for Dell - VMware

Dell EMC VxRail Overview

TheDell EMC VxRail Overviewdashboard provides at-a-glance heatmaps depicting the health of your host systems and virtual machines residing on VxRail, in addition to your VxRail resources. Select a resource on the left to populate its details on the right.

Management Pack for Dell EMC PowerEdge

VMware, Inc. 37

Page 38: EMC PowerEdge Management Pack for Dell - VMware

Reports (Dell EMC PowerEdge)

The Management Pack for Dell EMC PowerEdge contains out-of-the-box report(s) that you can export and easily share with key stakeholders in either .pdf or .csv formats.

The following reports are available in the Management Pack:

Report Description

Dell EMC Firmware Displays firmware information for Dell EMC objects.

Dell EMC Health and Availability Displays health and availability information for Dell EMC objects.

Dell EMC Server Overview Displays KPIs for Dell EMC Blade and Rack Servers.

To access Management Pack reports:

1 Navigate to Environment > All Objects > Dell EMC Cluster or PowerEdge.

2 Double-click on the desired object (resource).

3 Select the Reports tab, then Report Templates .

The available report(s) for the selected resource are listed and can be selected.

Management Pack for Dell EMC PowerEdge

VMware, Inc. 38

Page 39: EMC PowerEdge Management Pack for Dell - VMware

To run a selected report, click the Run Template icon.

Accessing Reports

Alerts (Dell EMC PowerEdge)

The Management Pack for Dell EMC PowerEdge pulls health status and events from your Dell EMC PowerEdge environments and displays them in vRealize Operations as alerts.See the table below for the list of alerts available in the Management Pack.

Name Description Symptom Recommendation

[Critical] Amperage Probe Status

[Critical] Amperage Probe Status

[Critical] Amperage Probe Status

No Recommendation

[Info] Amperage Probe Status [Info] Amperage Probe Status [Info] Amperage Probe Status No Recommendation

[Warning] Amperage Probe Status

[Warning] Amperage Probe Status

[Warning] Amperage Probe Status

No Recommendation

[Critical] Bios Status [Critical] Bios Status [Critical] Bios Status No Recommendation

[Info] Bios Status [Info] Bios Status [Info] Bios Status No Recommendation

[Warning] Bios Status [Warning] Bios Status [Warning] Bios Status No Recommendation

[Critical] Global Storage Status [Critical] Global Storage Status [Critical] Global Storage Status No Recommendation

[Info] Global Storage Status [Info] Global Storage Status [Info] Global Storage Status No Recommendation

[Warning] Global Storage Status

[Warning] Global Storage Status

[Warning] Global Storage Status

No Recommendation

[Critical] Global System Status [Critical] Global System Status [Critical] Global System Status No Recommendation

[Info] Global System Status [Info] Global System Status [Info] Global System Status No Recommendation

[Warning] Global System Status

[Warning] Global System Status

[Warning] Global System Status

No Recommendation

[Critical] LCD Status [Critical] LCD Status [Critical] LCD Status No Recommendation

[Info] LCD Status [Info] LCD Status [Info] LCD Status No Recommendation

Management Pack for Dell EMC PowerEdge

VMware, Inc. 39

Page 40: EMC PowerEdge Management Pack for Dell - VMware

Name Description Symptom Recommendation

[Warning] LCD Status [Warning] LCD Status [Warning] LCD Status No Recommendation

[Info] Power State [Info] Power State [Info] Power State No Recommendation

[Critical] Memory Device Status

[Critical] Memory Device Status

[Critical] Memory Device Status

No Recommendation

[Info] Memory Device Status [Info] Memory Device Status [Info] Memory Device Status No Recommendation

[Warning] Memory Device Status

[Warning] Memory Device Status

[Warning] Memory Device Status

No Recommendation

[Critical] Physical Disk State [Critical] Physical Disk State [Critical] Physical Disk State No Recommendation

[Info] Physical Disk State [Info] Physical Disk State [Info] Physical Disk State No Recommendation

[Warning] Physical Disk State [Warning] Physical Disk State [Warning] Physical Disk State No Recommendation

[Critical] Processor Device Status

[Critical] Processor Device Status

[Critical] Processor Device Status

No Recommendation

[Info] Processor Device Status [Info] Processor Device Status [Info] Processor Device Status No Recommendation

[Info] Processor Device Status State

[Info] Processor Device Status State

[Info] Processor Device Status State

No Recommendation

[Warning] Processor Device Status

[Warning] Processor Device Status

[Warning] Processor Device Status

No Recommendation

SNMP Event SNMP Event SNMP Event No Recommendation

[Critical] System Battery Reading

[Critical] System Battery Reading

[Critical] System Battery Reading

No Recommendation

[Info] System Battery Reading [Info] System Battery Reading [Info] System Battery Reading No Recommendation

[Warning] System Battery Reading

[Warning] System Battery Reading

[Warning] System Battery Reading

No Recommendation

[Critical] System Battery Status

[Critical] System Battery Status

[Critical] System Battery Status

No Recommendation

[Info] System Battery Status [Info] System Battery Status [Info] System Battery Status No Recommendation

[Warning] System Battery Status

[Warning] System Battery Status

[Warning] System Battery Status

No Recommendation

[Critical] Temperature Probe Status

[Critical] Temperature Probe Status

[Critical] Temperature Probe Status

No Recommendation

[Info] Temperature Probe Status

[Info] Temperature Probe Status

[Info] Temperature Probe Status

No Recommendation

[Warning] Temperature Probe Status

[Warning] Temperature Probe Status

[Warning] Temperature Probe Status

No Recommendation

[Critical] Virtual Disk Component Status

[Critical] Virtual Disk Component Status

[Critical] Virtual Disk Component Status

No Recommendation

[Info] Virtual Disk Component Status

[Info] Virtual Disk Component Status

[Info] Virtual Disk Component Status

No Recommendation

[Warning] Virtual Disk Component Status

[Warning] Virtual Disk Component Status

[Warning] Virtual Disk Component Status

No Recommendation

Management Pack for Dell EMC PowerEdge

VMware, Inc. 40

Page 41: EMC PowerEdge Management Pack for Dell - VMware

Name Description Symptom Recommendation

[Critical] Virtual Disk State [Critical] Virtual Disk State [Critical] Virtual Disk State No Recommendation

[Info] Virtual Disk State [Info] Virtual Disk State [Info] Virtual Disk State No Recommendation

[Warning] Virtual Disk State [Warning] Virtual Disk State [Warning] Virtual Disk State No Recommendation

[Critical] Voltage Probe Status [Critical] Voltage Probe Status [Critical] Voltage Probe Status No Recommendation

[Info] Voltage Probe Status [Info] Voltage Probe Status [Info] Voltage Probe Status No Recommendation

[Warning] Voltage Probe Status

[Warning] Voltage Probe Status

[Warning] Voltage Probe Status

No Recommendation

[Critical] Blade Status [Critical] Blade Status [Critical] Blade Status No Recommendation

[Info] Blade Status [Info] Blade Status [Info] Blade Status No Recommendation

[Warning] Blade Status [Warning] Blade Status [Warning] Blade Status No Recommendation

[Critical] CMC Status [Critical] CMC Status [Critical] CMC Status No Recommendation

[Info] CMC Status [Info] CMC Status [Info] CMC Status No Recommendation

[Warning] CMC Status [Warning] CMC Status [Warning] CMC Status No Recommendation

[Critical] Fan Status [Critical] Fan Status [Critical] Fan Status No Recommendation

[Info] Fan Status [Info] Fan Status [Info] Fan Status No Recommendation

[Warning] Fan Status [Warning] Fan Status [Warning] Fan Status No Recommendation

[Critical] Global Status [Critical] Global Status [Critical] Global Status No Recommendation

[Info] Global Status [Info] Global Status [Info] Global Status No Recommendation

[Warning] Global Status [Warning] Global Status [Warning] Global Status No Recommendation

[Critical] IKVM Status [Critical] IKVM Status [Critical] IKVM Status No Recommendation

[Info] IKVM Status [Info] IKVM Status [Info] IKVM Status No Recommendation

[Warning] IKVM Status [Warning] IKVM Status [Warning] IKVM Status No Recommendation

[Critical] IOM Status [Critical] IOM Status [Critical] IOM Status No Recommendation

[Info] IOM Status [Info] IOM Status [Info] IOM Status No Recommendation

[Warning] IOM Status [Warning] IOM Status [Warning] IOM Status No Recommendation

[Critical] Power Status [Critical] Power Status [Critical] Power Status No Recommendation

[Info] Power Status [Info] Power Status [Info] Power Status No Recommendation

[Warning] Power Status [Warning] Power Status [Warning] Power Status No Recommendation

[Critical] Redundancy Status [Critical] Redundancy Status [Critical] Redundancy Status No Recommendation

[Info] Redundancy Status [Info] Redundancy Status [Info] Redundancy Status No Recommendation

[Warning] Redundancy Status [Warning] Redundancy Status [Warning] Redundancy Status No Recommendation

[Critical] Temperature Status [Critical] Temperature Status [Critical] Temperature Status No Recommendation

[Info] Temperature Status [Info] Temperature Status [Info] Temperature Status No Recommendation

[Warning] Temperature Status [Warning] Temperature Status [Warning] Temperature Status No Recommendation

[Critical] Amperage Probe Status

[Critical] Amperage Probe Status

[Critical] Amperage Probe Status

No Recommendation

Management Pack for Dell EMC PowerEdge

VMware, Inc. 41

Page 42: EMC PowerEdge Management Pack for Dell - VMware

Name Description Symptom Recommendation

[Info] Amperage Probe Status [Info] Amperage Probe Status [Info] Amperage Probe Status No Recommendation

[Warning] Amperage Probe Status

[Warning] Amperage Probe Status

[Warning] Amperage Probe Status

No Recommendation

[Critical] Cooling Device Status [Critical] Cooling Device Status [Critical] Cooling Device Status No Recommendation

[Info] Cooling Device Status [Info] Cooling Device Status [Info] Cooling Device Status No Recommendation

[Critical] Intrusion Probe Reading

[Critical] Intrusion Probe Reading

[Critical] Intrusion Probe Reading

No Recommendation

[Info] Intrusion Probe Reading [Info] Intrusion Probe Reading [Info] Intrusion Probe Reading No Recommendation

[Warning] Intrusion Probe Reading

[Warning] Intrusion Probe Reading

[Warning] Intrusion Probe Reading

No Recommendation

[Critical] Intrusion Probe Status [Critical] Intrusion Probe Status [Critical] Intrusion Probe Status No Recommendation

[Info] Intrusion Probe Status [Info] Intrusion Probe Status [Info] Intrusion Probe Status No Recommendation

[Warning] Intrusion Probe Status

[Warning] Intrusion Probe Status

[Warning] Intrusion Probe Status

No Recommendation

[Critical] Memory Device Status

[Critical] Memory Device Status

[Critical] Memory Device Status

No Recommendation

[Info] Memory Device Status [Info] Memory Device Status [Info] Memory Device Status No Recommendation

[Warning] Memory Device Status

[Warning] Memory Device Status

[Warning] Memory Device Status

No Recommendation

[Critical] Physical Disk State [Critical] Physical Disk State [Critical] Physical Disk State No Recommendation

[Info] Physical Disk State [Info] Physical Disk State [Info] Physical Disk State No Recommendation

[Warning] Physical Disk State [Warning] Physical Disk State [Warning] Physical Disk State No Recommendation

[Critical] Power Unit Status [Critical] Power Unit Status [Critical] Power Unit Status No Recommendation

[Info] Power Unit Status [Info] Power Unit Status [Info] Power Unit Status No Recommendation

[Warning] Power Unit Status [Warning] Power Unit Status [Warning] Power Unit Status No Recommendation

[Critical] Processor Device Status

[Critical] Processor Device Status

[Critical] Processor Device Status

No Recommendation

[Info] Processor Device Status [Info] Processor Device Status [Info] Processor Device Status No Recommendation

[Info] Processor Device Status State

[Info] Processor Device Status State

[Info] Processor Device Status State

No Recommendation

[Warning] Processor Device Status

[Warning] Processor Device Status

[Warning] Processor Device Status

No Recommendation

[Critical] Power Supply Sensor State

[Critical] Power Supply Sensor State

[Critical] Power Supply Sensor State

No Recommendation

[Info] Power Supply Sensor State

[Info] Power Supply Sensor State

[Info] Power Supply Sensor State

No Recommendation

[Warning] Power Supply Sensor State

[Warning] Power Supply Sensor State

[Warning] Power Supply Sensor State

No Recommendation

Management Pack for Dell EMC PowerEdge

VMware, Inc. 42

Page 43: EMC PowerEdge Management Pack for Dell - VMware

Name Description Symptom Recommendation

[Critical] Power Supply State Settings Unique

[Critical] Power Supply State Settings Unique

[Critical] Power Supply State Settings Unique

No Recommendation

[Info] Power Supply State Settings Unique

[Info] Power Supply State Settings Unique

[Info] Power Supply State Settings Unique

No Recommendation

[Warning] Power Supply State Settings Unique

[Warning] Power Supply State Settings Unique

[Warning] Power Supply State Settings Unique

No Recommendation

[Critical] Power Supply Status [Critical] Power Supply Status [Critical] Power Supply Status No Recommendation

[Info] Power Supply Status [Info] Power Supply Status [Info] Power Supply Status No Recommendation

[Warning] Power Supply Status

[Warning] Power Supply Status

[Warning] Power Supply Status

No Recommendation

[Critical] Bios Status [Critical] Bios Status [Critical] Bios Status No Recommendation

[Info] Bios Status [Info] Bios Status [Info] Bios Status No Recommendation

[Warning] Bios Status [Warning] Bios Status [Warning] Bios Status No Recommendation

[Critical] Global Storage Status [Critical] Global Storage Status [Critical] Global Storage Status No Recommendation

[Info] Global Storage Status [Info] Global Storage Status [Info] Global Storage Status No Recommendation

[Warning] Global Storage Status

[Warning] Global Storage Status

[Warning] Global Storage Status

No Recommendation

[Critical] Global System Status [Critical] Global System Status [Critical] Global System Status No Recommendation

[Info] Global System Status [Info] Global System Status [Info] Global System Status No Recommendation

[Warning] Global System Status

[Warning] Global System Status

[Warning] Global System Status

No Recommendation

[Critical] LCD Status [Critical] LCD Status [Critical] LCD Status No Recommendation

[Info] LCD Status [Info] LCD Status [Info] LCD Status No Recommendation

[Warning] LCD Status [Warning] LCD Status [Warning] LCD Status No Recommendation

[Info] Power State [Info] Power State [Info] Power State No Recommendation

SNMP Event SNMP Event SNMP Event No Recommendation

[Critical] System Battery Reading

[Critical] System Battery Reading

[Critical] System Battery Reading

No Recommendation

[Info] System Battery Reading [Info] System Battery Reading [Info] System Battery Reading No Recommendation

[Warning] System Battery Reading

[Warning] System Battery Reading

[Warning] System Battery Reading

No Recommendation

[Critical] System Battery Status

[Critical] System Battery Status

[Critical] System Battery Status

No Recommendation

[Info] System Battery Status [Info] System Battery Status [Info] System Battery Status No Recommendation

[Warning] System Battery Status

[Warning] System Battery Status

[Warning] System Battery Status

No Recommendation

[Critical] Temperature Probe Status

[Critical] Temperature Probe Status

[Critical] Temperature Probe Status

No Recommendation

Management Pack for Dell EMC PowerEdge

VMware, Inc. 43

Page 44: EMC PowerEdge Management Pack for Dell - VMware

Name Description Symptom Recommendation

[Info] Temperature Probe Status

[Info] Temperature Probe Status

[Info] Temperature Probe Status

No Recommendation

[Warning] Temperature Probe Status

[Warning] Temperature Probe Status

[Warning] Temperature Probe Status

No Recommendation

[Critical] Voltage Probe Status [Critical] Voltage Probe Status [Critical] Voltage Probe Status No Recommendation

[Info] Voltage Probe Status [Info] Voltage Probe Status [Info] Voltage Probe Status No Recommendation

[Warning] Voltage Probe Status

[Warning] Voltage Probe Status

[Warning] Voltage Probe Status

No Recommendation

See also:

Metrics (Dell EMC PowerEdge)

Metrics (Dell EMC PowerEdge)

The Management Pack for Dell EMC PowerEdge collects the metrics listed in the table below, according to resource kind.

Download metrics list as .csv file

Resource Kind Resource Group Resource Attribute Attribute Type

Dell EMC Amperage Probe

Details Chassis Index The Chassis Index of the Amperage Probe.

Dell EMC Amperage Probe

Details Index The Index of the Amperage Probe.

Dell EMC Amperage Probe

Details Location The Location of the Amperage Probe.

Dell EMC Amperage Probe

Details Power Supply The Power Supply of the Amperage Probe.

Dell EMC Amperage Probe

Details Power Supply Power The Power Supply Power of the Amperage Probe.

Dell EMC Amperage Probe

Details Probe Current The Power Supply Power of the Amperage Probe.

Dell EMC Amperage Probe

Details Server Current The Server Amperage of the Amperage Probe.

Dell EMC Amperage Probe

Details Server Power The Server Power of the Amperage Probe.

Dell EMC Amperage Probe

Details Service Tag The Service Tag of the Amperage Probe.

Dell EMC Amperage Probe

Status Status The Status of the Amperage Probe.

Dell EMC Amperage Probe

Details Type Type

Management Pack for Dell EMC PowerEdge

VMware, Inc. 44

Page 45: EMC PowerEdge Management Pack for Dell - VMware

Resource Kind Resource Group Resource Attribute Attribute Type

Dell EMC Blade Server Status Amperage Probe Relatives in Healthy State

The percentage of relatives of type amperage_probe whose status doesn't warrant creating an event.

Dell EMC Blade Server Details Amperage Probes The Amperage Probes of the Blade Server.

Dell EMC Blade Server Memory Average Memory Device Size

The Average Memory Device Size of the Blade Server.

Dell EMC Blade Server Memory Average Memory Device Speed

The Average Memory Device Speed of the Blade Server.

Dell EMC Blade Server Disk Average Physical Disk Available RAID

The Average Physical Disk Available RAID of the Blade Server.

Dell EMC Blade Server Disk Average Physical Disk Capacity

The Average Physical Disk Capacity of the Blade Server.

Dell EMC Blade Server Disk Average Physical Disk Used RAID

The Average Physical Disk Used RAID of the Blade Server.

Dell EMC Blade Server Performance Average Processor Speed

The Average Processor Device Current Speed of the Blade Server.

Dell EMC Blade Server Details Average Processor Voltage

The Average Processor Device Voltage of the Blade Server.

Dell EMC Blade Server Details Average Server Current The Average Server Amperage of the Blade Server.

Dell EMC Blade Server Details Average Server Power The Average Server Power of the Blade Server.

Dell EMC Blade Server Details Average Temperature Probe Reading

The Average Temperature Probe Reading of the Blade Server.

Dell EMC Blade Server Disk Average Virtual Disk Capacity

The Average Virtual Disk Capacity of the Blade Server.

Dell EMC Blade Server Details Blade Slot Number The Blade Slot Number of the Blade Server.

Dell EMC Blade Server Details Express Service Code The Express Service Code of the Blade Server.

Dell EMC Blade Server Details Form Factor The Form Factor of the Blade Server.

Dell EMC Blade Server Details FQDN The FQDN of the Blade Server.

Dell EMC Blade Server Status Global Storage Status The Storage Status of the Blade Server.

Dell EMC Blade Server Status Global Server Status The Global Server Status of the Blade Server.

Dell EMC Blade Server Memory Highest Memory Device Size

The Largest Memory Device Size of the Blade Server.

Dell EMC Blade Server Performance Highest Memory Device Speed

The Fastest Memory Device Speed of the Blade Server.

Dell EMC Blade Server Disk Highest Physical Disk Available RAID

The Largest Physical Disk Available RAID of the Blade Server.

Dell EMC Blade Server Disk Highest Physical Disk Capacity

The Largest Physical Disk Capacity of the Blade Server.

Dell EMC Blade Server Disk Highest Physical Disk Used RAID

The Largest Physical Disk Used RAID of the Blade Server.

Management Pack for Dell EMC PowerEdge

VMware, Inc. 45

Page 46: EMC PowerEdge Management Pack for Dell - VMware

Resource Kind Resource Group Resource Attribute Attribute Type

Dell EMC Blade Server Performance Highest Processor Speed

The Fastest Processor Device Current Speed of the Blade Server.

Dell EMC Blade Server Details Highest Processor Voltage

The Highest Processor Device Voltage of the Blade Server.

Dell EMC Blade Server Details Highest Server Current The Highest Server Amperage of the Blade Server.

Dell EMC Blade Server Details Highest Server Power The Highest Server Power of the Blade Server.

Dell EMC Blade Server Details Highest Temperature Probe Reading

The Highest Temperature Probe Reading of the Blade Server.

Dell EMC Blade Server Disk Highest Virtual Disk Capacity

The Largest Virtual Disk Capacity of the Blade Server.

Dell EMC Blade Server Details ID The ID of the Blade Server.

Dell EMC Blade Server Status LCD Status The LCD Status of the Blade Server.

Dell EMC Blade Server Memory Lowest Memory Device Size

The Smallest Memory Device Size of the Blade Server.

Dell EMC Blade Server Performance Lowest Memory Device Speed

The Slowest Memory Device Speed of the Blade Server.

Dell EMC Blade Server Disk Lowest Physical Disk Available RAID

The Smallest Physical Disk Available RAID of the Blade Server.

Dell EMC Blade Server Disk Lowest Physical Disk Capacity

The Smallest Physical Disk Capacity of the Blade Server.

Dell EMC Blade Server Disk Lowest Physical Disk Used RAID

The Smallest Physical Disk Used RAID of the Blade Server.

Dell EMC Blade Server Performance Lowest Processor Speed

The Slowest Processor Device Current Speed of the Blade Server.

Dell EMC Blade Server Disk Lowest Processor Voltage

The Lowest Processor Device Voltage of the Blade Server.

Dell EMC Blade Server Details Lowest Server Current The Lowest Server Amperage of the Blade Server.

Dell EMC Blade Server Details Lowest Server Power The Lowest Server Power of the Blade Server.

Dell EMC Blade Server Details Lowest Temperature Probe Reading

The Lowest Temperature Probe Reading of the Blade Server.

Dell EMC Blade Server Disk Lowest Virtual Disk Capacity

The Smallest Virtual Disk Capacity of the Blade Server.

Dell EMC Blade Server Details MAC Addresses The MAC Addresses of the Blade Server.

Dell EMC Blade Server Details Management IP The Management IP of the Blade Server.

Dell EMC Blade Server Status Memory Device Relatives in Healthy State

The percentage of relatives of type memory_device whose status doesn't warrant creating an event.

Dell EMC Blade Server Details Memory Devices The Memory Devices of the Blade Server.

Dell EMC Blade Server Details Model Name The Model Name of the Blade Server.

Management Pack for Dell EMC PowerEdge

VMware, Inc. 46

Page 47: EMC PowerEdge Management Pack for Dell - VMware

Resource Kind Resource Group Resource Attribute Attribute Type

Dell EMC Blade Server Details Operating System Name

The OS Name of the Blade Server.

Dell EMC Blade Server Status Physical Disk Relatives in Healthy State

The percentage of relatives of type physical_disk whose status doesn't warrant creating an event.

Dell EMC Blade Server Details Physical Disks The Physical Disks of the Blade Server.

Dell EMC Blade Server Details Power State The Power State of the Blade Server.

Dell EMC Blade Server Status Processor Device Relatives in Healthy State

The percentage of relatives of type processor_device whose status doesn't warrant creating an event.

Dell EMC Blade Server Details Processor Devices The Processor Devices of the Blade Server.

Dell EMC Blade Server Details RAC Description The RAC Description of the Blade Server.

Dell EMC Blade Server Details RAC Firmware Version The RAC Firmware Version of the Blade Server.

Dell EMC Blade Server Details RAC Manufacturer The RAC Manufacturer of the Blade Server.

Dell EMC Blade Server Details RAC Name The RAC Name of the Blade Server.

Dell EMC Blade Server Details RAC Type The RAC Type of the Blade Server.

Dell EMC Blade Server Details RAC URL The RAC URL of the Blade Server.

Dell EMC Blade Server Details RAC Version The RAC Version of the Blade Server.

Dell EMC Blade Server Details Rack Slot The Rack Slot of the Blade Server.

Dell EMC Blade Server Details Service Tag The Service Tag of the Blade Server.

Dell EMC Blade Server Status State Settings The State Settings of the Blade Server.

Dell EMC Blade Server Status Status The Status of the Blade Server.

Dell EMC Blade Server Details System Batteries The System Batteries of the Blade Server.

Dell EMC Blade Server Status System Battery Relatives in Healthy State

The percentage of relatives of type system_battery whose status doesn't warrant creating an event.

Dell EMC Blade Server Status Temperature Probe Relatives in Healthy State

The percentage of relatives of type temperature_probe whose status doesn't warrant creating an event.

Dell EMC Blade Server Details Temperature Probes The Temperature Probes of the Blade Server.

Dell EMC Blade Server Memory Total Memory Device Size

The Total Memory Device Size of the Blade Server.

Dell EMC Blade Server Disk Total Physical Disk Available RAID

The Total Physical Disk Available RAID of the Blade Server.

Dell EMC Blade Server Disk Total Physical Disk Capacity

The Total Physical Disk Capacity of the Blade Server.

Dell EMC Blade Server Disk Total Physical Disk Used RAID

The Total Physical Disk Used RAID of the Blade Server.

Dell EMC Blade Server Details Total Processor Cores The Total Processor Device Core Count of the Blade Server.

Management Pack for Dell EMC PowerEdge

VMware, Inc. 47

Page 48: EMC PowerEdge Management Pack for Dell - VMware

Resource Kind Resource Group Resource Attribute Attribute Type

Dell EMC Blade Server Details Total Server Current The Total Server Amperage of the total_processorServer.

Dell EMC Blade Server Details Total Server Power The Total Server Power of the Blade Server.

Dell EMC Blade Server Disk Total Virtual Disk Capacity

The Total Virtual Disk Capacity of the Blade Server.

Dell EMC Blade Server Details Version The Version of the Blade Server.

Dell EMC Blade Server Status Virtual Disk Relatives in Healthy State

The percentage of relatives of type virtual_disk whose status doesn't warrant creating an event.

Dell EMC Blade Server Details Virtual Disks The Virtual Disks of the Blade Server.

Dell EMC Blade Server Status Voltage Probe Relatives in Healthy State

The percentage of relatives of type voltage_probe whose status doesn't warrant creating an event.

Dell EMC Blade Server Details Voltage Probes The Voltage Probes of the Blade Server.

Dell EMC Blade Server Details Host Name Host Name

Dell EMC Chassis Details Blade Server Service Tags

The Blade Server Service Tags of the Chassis.

Dell EMC Chassis Details Blade Server Slot Names

The Blade Server Slot Names of the Chassis.

Dell EMC Chassis Status Blade Status The Blade Status of the Chassis.

Dell EMC Chassis Details Service Tag The Service Tag of the Chassis.

Dell EMC Chassis Details CMC Card Temperature The CMC Card Temperature of the Chassis.

Dell EMC Chassis Details CMC Processor Temperature

The CMC Processor Temperature of the Chassis.

Dell EMC Chassis Status CMC Status The CMC Status of the Chassis.

Dell EMC Chassis Details Cumulative Power Usage

The Cumulative Power Usage of the Chassis.

Dell EMC Chassis Details Express Service Code The Express Service Code of the Chassis.

Dell EMC Chassis Status Fan Status The Fan Status of the Chassis.

Dell EMC Chassis Details Front Panel Temperature

The Front Panel Temperature of the Chassis.

Dell EMC Chassis Status iKVM Status The iKVM Status of the Chassis.

Dell EMC Chassis Details Idle Power The Idle Power of the Chassis.

Dell EMC Chassis Details Instantaneous Current Usage

The Instantaneous Current Usage of the Chassis.

Dell EMC Chassis Details Instantaneous Power Usage

The Instantaneous Power Usage of the Chassis.

Dell EMC Chassis Status IOM Status The IOM Status of the Chassis.

Dell EMC Chassis Details Last Minimum Usage Reset

The Last Minimum Usage Reset of the Chassis.

Management Pack for Dell EMC PowerEdge

VMware, Inc. 48

Page 49: EMC PowerEdge Management Pack for Dell - VMware

Resource Kind Resource Group Resource Attribute Attribute Type

Dell EMC Chassis Details Last Peak Usage Reset The Last Peak Usage Reset of the Chassis.

Dell EMC Chassis Details Last Power Usage Reset

The Last Power Usage Reset of the Chassis.

Dell EMC Chassis Details Location The Location of the Chassis.

Dell EMC Chassis Details Management IP The Management IP of the Chassis.

Dell EMC Chassis Details Maximum Power Specification

The Maximum Power Specification of the Chassis.

Dell EMC Chassis Details Minimum Usage The Minimum Usage of the Chassis.

Dell EMC Chassis Details Model The Model of the Chassis.

Dell EMC Chassis Details Name The Name of the Chassis.

Dell EMC Chassis Details Peak Usage The Peak Usage of the Chassis.

Dell EMC Chassis Details Potential Power The Potential Power of the Chassis.

Dell EMC Chassis Status Power Status The Power Status of the Chassis.

Dell EMC Chassis Details Power Supplies The Power Supplies of the Chassis.

Dell EMC Chassis Details Power Surplus The Power Surplus of the Chassis.

Dell EMC Chassis Status Redundancy Status The Redundancy Status of the Chassis.

Dell EMC Chassis Details Size The Size of the Chassis.

Dell EMC Chassis Status Status The Status of the Chassis.

Dell EMC Chassis Details System ID The System ID of the Chassis.

Dell EMC Chassis Status Temperature Status The Temperature Status of the Chassis.

Dell EMC Chassis Power Supply

Details Chassis Index The Chassis Index of the Chassis Power Supply.

Dell EMC Chassis Power Supply

Details Service Tag The Service Tag of the Chassis Power Supply.

Dell EMC Chassis Power Supply

Details Current The Amps Reading of the Chassis Power Supply.

Dell EMC Chassis Power Supply

Details Index The Index of the Chassis Power Supply.

Dell EMC Chassis Power Supply

Details Location The Location of the Chassis Power Supply.

Dell EMC Chassis Power Supply

Details Monitoring Capable The Monitoring Capable of the Chassis Power Supply.

Dell EMC Chassis Power Supply

Details Power The Watts Reading of the Chassis Power Supply.

Dell EMC Chassis Power Supply

Details Voltage The Volts Reading of the Chassis Power Supply.

Dell EMC Cooling Device

Details Chassis Index The Chassis Index of the Cooling Device.

Management Pack for Dell EMC PowerEdge

VMware, Inc. 49

Page 50: EMC PowerEdge Management Pack for Dell - VMware

Resource Kind Resource Group Resource Attribute Attribute Type

Dell EMC Cooling Device

Details Index The Index of the Cooling Device.

Dell EMC Cooling Device

Details Is Turned On The Is Turned On of the Cooling Device.

Dell EMC Cooling Device

Details Location The Location of the Cooling Device.

Dell EMC Cooling Device

Details Name The Name of the Cooling Device.

Dell EMC Cooling Device

Details Service Tag The Service Tag of the Cooling Device.

Dell EMC Cooling Device

Performance Speed The Speed of the Cooling Device.

Dell EMC Cooling Device

Status Status The Status of the Cooling Device.

Dell EMC Cooling Device

Details Type The Type of the Cooling Device.

Dell EMC Intrusion Probe

Details Chassis Index The Chassis Index of the Intrusion Probe.

Dell EMC Intrusion Probe

Details Index The Index of the Intrusion Probe.

Dell EMC Intrusion Probe

Details Location The Location of the Intrusion Probe.

Dell EMC Intrusion Probe

Details Reading The Reading of the Intrusion Probe.

Dell EMC Intrusion Probe

Details Service Tag The Service Tag of the Intrusion Probe.

Dell EMC Intrusion Probe

Status State Capabilities The State Capabilities of the Intrusion Probe.

Dell EMC Intrusion Probe

Status State Settings The State Settings of the Intrusion Probe.

Dell EMC Intrusion Probe

Status Status The Status of the Intrusion Probe.

Dell EMC Intrusion Probe

Details Type The Type of the Intrusion Probe.

Dell EMC Memory Device

Details Chassis Index The Chassis Index of the Memory Device.

Dell EMC Memory Device

Details Index The Index of the Memory Device.

Dell EMC Memory Device

Details Location The Location of the Memory Device.

Dell EMC Memory Device

Details Part Number The Part Number of the Memory Device.

Management Pack for Dell EMC PowerEdge

VMware, Inc. 50

Page 51: EMC PowerEdge Management Pack for Dell - VMware

Resource Kind Resource Group Resource Attribute Attribute Type

Dell EMC Memory Device

Details Serial Number The Serial Number of the Memory Device.

Dell EMC Memory Device

Details Service Tag The Service Tag of the Memory Device.

Dell EMC Memory Device

Memory Size The Size of the Memory Device.

Dell EMC Memory Device

Performance Speed The Speed of the Memory Device.

Dell EMC Memory Device

Status Status The Memory Device Status of the Memory Device.

Dell EMC Physical Disk Disk Available RAID Disk Space

The Available RAID Disk Space of the Physical Disk.

Dell EMC Physical Disk Disk Capacity The Capacity of the Physical Disk.

Dell EMC Physical Disk Details Fully Qualified Device Descriptor

The Fully Qualified Device Descriptor of the Physical Disk.

Dell EMC Physical Disk Details Media Type The Media Type of the Physical Disk.

Dell EMC Physical Disk Details Number The Number of the Physical Disk.

Dell EMC Physical Disk Status Operational State The Physical Disk Operational State of the Physical Disk.

Dell EMC Physical Disk Details Part Number The Part Number of the Physical Disk.

Dell EMC Physical Disk Status Power State The Physical Disk Power State of the Physical Disk.

Dell EMC Physical Disk Status Security Status The Physical Security Disk State of the Physical Disk.

Dell EMC Physical Disk Details Serial Number The Serial Number of the Physical Disk.

Dell EMC Physical Disk Details Service Tag The Service Tag of the Physical Disk.

Dell EMC Physical Disk Status State The Physical Disk State of the Physical Disk.

Dell EMC Physical Disk Disk Used RAID Disk Space The Used RAID Disk Space of the Physical Disk.

Dell EMC Power Unit Details Average Output Power The Average Output Power of the Power Unit.

Dell EMC Power Unit Details Average Rated Input Power

The Average Rated Input Power of the Power Unit.

Dell EMC Power Unit Details Chassis Index The Chassis Index of the Power Unit.

Dell EMC Power Unit Details Count For Redundancy The Count For Redundancy of the Power Unit.

Dell EMC Power Unit Details Highest Input Voltage The Highest Input Voltage of the Power Unit.

Dell EMC Power Unit Details Highest Output Power The Highest Output Power of the Power Unit.

Dell EMC Power Unit Details Highest Rated Input Power

The Highest Rated Input Power of the Power Unit.

Dell EMC Power Unit Details Index The Index of the Power Unit.

Dell EMC Power Unit Details Lowest Input Voltage The Lowest Input Voltage of the Power Unit.

Management Pack for Dell EMC PowerEdge

VMware, Inc. 51

Page 52: EMC PowerEdge Management Pack for Dell - VMware

Resource Kind Resource Group Resource Attribute Attribute Type

Dell EMC Power Unit Details Lowest Output Power The Lowest Output Power of the Power Unit.

Dell EMC Power Unit Details Lowest Rated Input Power

The Lowest Rated Input Power of the Power Unit.

Dell EMC Power Unit Details Name The Name of the Power Unit.

Dell EMC Power Unit Details Service Tag The Service Tag of the Power Unit.

Dell EMC Power Unit Status Status The Power Unit Status of the Power Unit.

Dell EMC Power Unit Details Total Input Voltage The Total Input Voltage of the Power Unit.

Dell EMC Power Unit Details Total Output Power The Total Output Power of the Power Unit.

Dell EMC Power Unit Details Total Rated Input Power The Total Rated Input Power of the Power Unit.

Dell EMC Processor Device

Details Brand The Brand Name of the Processor Device.

Dell EMC Processor Device

Details Chassis Index The Chassis Index of the Processor Device.

Dell EMC Processor Device

Details Cores The Cores of the Processor Device.

Dell EMC Processor Device

Details Cores Enabled The Cores Enabled of the Processor Device.

Dell EMC Processor Device

Performance Current Speed The Current Speed of the Processor Device.

Dell EMC Processor Device

Details Index The Index of the Processor Device.

Dell EMC Processor Device

Details Manufacturer The Manufacturer of the Processor Device.

Dell EMC Processor Device

Details Service Tag The Service Tag of the Processor Device.

Dell EMC Processor Device

Status Status The Processor Device Status of the Processor Device.

Dell EMC Processor Device

Status Status State The Processor Device Status State of the Processor Device.

Dell EMC Processor Device

Details Threads The Threads of the Processor Device.

Dell EMC Processor Device

Details Version The Version of the Processor Device.

Dell EMC Processor Device

Details Voltage The Voltage of the Processor Device.

Dell EMC Rack Power Supply

Details Chassis Index The Chassis Index of the Rack Power Supply.

Dell EMC Rack Power Supply

Details Index The Index of the Rack Power Supply.

Dell EMC Rack Power Supply

Details Input Voltage The Input Voltage of the Rack Power Supply.

Management Pack for Dell EMC PowerEdge

VMware, Inc. 52

Page 53: EMC PowerEdge Management Pack for Dell - VMware

Resource Kind Resource Group Resource Attribute Attribute Type

Dell EMC Rack Power Supply

Details Output Power The Output Power of the Rack Power Supply.

Dell EMC Rack Power Supply

Details Power Unit Index Reference

The Power Unit Index Reference of the Rack Power Supply.

Dell EMC Rack Power Supply

Details Rated Input Power The Rated Input Power of the Rack Power Supply.

Dell EMC Rack Power Supply

Status Sensor State The Power Supply Sensor State of the Rack Power Supply.

Dell EMC Rack Power Supply

Details Service Tag The Service Tag of the Rack Power Supply.

Dell EMC Rack Power Supply

Status State Settings Unique The Power Supply State Settings Unique of the Rack Power Supply.

Dell EMC Rack Power Supply

Status Status The Power Supply Status of the Rack Power Supply.

Dell EMC Rack Server Status Amperage Probe Relatives in Healthy State

The percentage of relatives of type amperage_probe whose status doesn't warrant creating an event.

Dell EMC Rack Server Details Amperage Probes The Amperage Probes of the Rack Server.

Dell EMC Rack Server Memory Average Memory Device Size

The Average Memory Device Size of the Rack Server.

Dell EMC Rack Server Performance Average Memory Device Speed

The Average Memory Device Speed of the Rack Server.

Dell EMC Rack Server Disk Average Physical Disk Available RAID

The Average Physical Disk Available RAID of the Rack Server.

Dell EMC Rack Server Disk Average Physical Disk Capacity

The Average Physical Disk Capacity of the Rack Server.

Dell EMC Rack Server Disk Average Physical Disk Used RAID

The Average Physical Disk Used RAID of the Rack Server.

Dell EMC Rack Server Details Average Power Supply The Average Power Supply of the Rack Server.

Dell EMC Rack Server Performance Average Processor Speed

The Average Processor Device Current Speed of the Rack Server.

Dell EMC Rack Server Details Average Processor Voltage

The Average Processor Device Voltage of the Rack Server.

Dell EMC Rack Server Details Average Server Power The Average Server Power of the Rack Server.

Dell EMC Rack Server Details Average Temperature Probe Reading

The Average Temperature Probe Reading of the Rack Server.

Dell EMC Rack Server Details Average Voltage Probe Reading

The Average Voltage Probe Reading of the Rack Server.

Dell EMC Rack Server Status Cooling Device Relatives in Healthy State

The percentage of relatives of type cooling_device whose status doesn't warrant creating an event.

Dell EMC Rack Server Details Cooling Devices The Cooling Devices of the Rack Server.

Management Pack for Dell EMC PowerEdge

VMware, Inc. 53

Page 54: EMC PowerEdge Management Pack for Dell - VMware

Resource Kind Resource Group Resource Attribute Attribute Type

Dell EMC Rack Server Details Express Service Code The Express Service Code of the Rack Server.

Dell EMC Rack Server Details Form Factor The Form Factor of the Rack Server.

Dell EMC Rack Server Details FQDN The FQDN of the Rack Server.

Dell EMC Rack Server Status global Storage Status The Storage Status of the Rack Server.

Dell EMC Rack Server Status Global Server Status The Global Server Status of the Rack Server.

Dell EMC Rack Server Memory Highest Memory Device Size

The Largest Memory Device Size of the Rack Server.

Dell EMC Rack Server Performance Highest Memory Device Speed

The Fastest Memory Device Speed of the Rack Server.

Dell EMC Rack Server Disk Highest Physical Disk Available RAID

The Largest Physical Disk Available RAID of the Rack Server.

Dell EMC Rack Server Disk Highest Physical Disk Capacity

The Largest Physical Disk Capacity of the Rack Server.

Dell EMC Rack Server Disk Highest Physical Disk Used RAID

The Largest Physical Disk Used RAID of the Rack Server.

Dell EMC Rack Server Details Highest Power Supply The Highest Power Supply of the Rack Server.

Dell EMC Rack Server Performance Highest Processor Speed

The Fastest Processor Device Current Speed of the Rack Server.

Dell EMC Rack Server Details Highest Processor Voltage

The Highest Processor Device Voltage of the Rack Server.

Dell EMC Rack Server Details Highest Server Power The Highest Server Power of the Rack Server.

Dell EMC Rack Server Details Highest Temperature Probe Reading

The Highest Temperature Probe Reading of the Rack Server.

Dell EMC Rack Server Details Highest Voltage Probe Reading

The Highest Voltage Probe Reading of the Rack Server.

Dell EMC Rack Server Details ID The ID of the Rack Server.

Dell EMC Rack Server Status Intrusion Probe Relatives in Healthy State

The percentage of relatives of type intrusion_probe whose status doesn't warrant creating an event.

Dell EMC Rack Server Details Intrusion Probes The Intrusion Probes of the Rack Server.

Dell EMC Rack Server Status LCD Status The LCD Status of the Rack Server.

Dell EMC Rack Server Memory Lowest Memory Device Size

The Smallest Memory Device Size of the Rack Server.

Dell EMC Rack Server Performance Lowest Memory Device Speed

The Slowest Memory Device Speed of the Rack Server.

Dell EMC Rack Server Disk Lowest Physical Disk Available RAID

The Smallest Physical Disk Available RAID of the Rack Server.

Dell EMC Rack Server Disk Lowest Physical Disk Capacity

The Smallest Physical Disk Capacity of the Rack Server.

Management Pack for Dell EMC PowerEdge

VMware, Inc. 54

Page 55: EMC PowerEdge Management Pack for Dell - VMware

Resource Kind Resource Group Resource Attribute Attribute Type

Dell EMC Rack Server Disk Lowest Physical Disk Used RAID

The Smallest Physical Disk Used RAID of the Rack Server.

Dell EMC Rack Server Details Lowest Power Supply The Lowest Power Supply of the Rack Server.

Dell EMC Rack Server Performance Lowest Processor Speed

The Slowest Processor Device Current Speed of the Rack Server.

Dell EMC Rack Server Details Lowest Processor Voltage

The Lowest Processor Device Voltage of the Rack Server.

Dell EMC Rack Server Details Lowest Server Power The Lowest Server Power of the Rack Server.

Dell EMC Rack Server Details Lowest Temperature Probe Reading

The Lowest Temperature Probe Reading of the Rack Server.

Dell EMC Rack Server Details Lowest Voltage Probe Reading

The Lowest Voltage Probe Reading of the Rack Server.

Dell EMC Rack Server Details MAC Addresses The MAC Addresses of the Rack Server.

Dell EMC Rack Server Details Management IP The Management IP of the Rack Server.

Dell EMC Rack Server Status Memory Device Relatives in Healthy State

The percentage of relatives of type memory_device whose status doesn't warrant creating an event.

Dell EMC Rack Server Details Memory Devices The Memory Devices of the Rack Server.

Dell EMC Rack Server Details Model Name The Model Name of the Rack Server.

Dell EMC Rack Server Details Operating System Name

The OS Name of the Rack Server.

Dell EMC Rack Server Details OS Version The OS Version of the Rack Server.

Dell EMC Rack Server Status Physical Disk Relatives in Healthy State

The percentage of relatives of type physical_disk whose status doesn't warrant creating an event.

Dell EMC Rack Server Details Physical Disks The Physical Disks of the Rack Server.

Dell EMC Rack Server Status Power State The Power State of the Rack Server.

Dell EMC Rack Server Status Power Unit Relatives in Healthy State

The percentage of relatives of type power_unit whose status doesn't warrant creating an event.

Dell EMC Rack Server Details Power Units The Power Units of the Rack Server.

Dell EMC Rack Server Status Processor Device Relatives in Healthy State

The percentage of relatives of type processor_device whose status doesn't warrant creating an event.

Dell EMC Rack Server Details Processor Devices The Processor Devices of the Rack Server.

Dell EMC Rack Server Details RAC Description The RAC Description of the Rack Server.

Dell EMC Rack Server Details RAC Firmware Version The RAC Firmware Version of the Rack Server.

Dell EMC Rack Server Details RAC Manufacturer The RAC Manufacturer of the Rack Server.

Dell EMC Rack Server Details RAC Name The RAC Name of the Rack Server.

Dell EMC Rack Server Details RAC Type The RAC Type of the Blade Server.

Dell EMC Rack Server Details RAC URL The RAC URL of the Rack Server.

Management Pack for Dell EMC PowerEdge

VMware, Inc. 55

Page 56: EMC PowerEdge Management Pack for Dell - VMware

Resource Kind Resource Group Resource Attribute Attribute Type

Dell EMC Rack Server Details RAC Version The RAC Version of the Rack Server.

Dell EMC Rack Server Status Rack Power Supply Relatives in Healthy State

The percentage of relatives of type rack_power_supply whose status doesn't warrant creating an event.

Dell EMC Rack Server Details Rack Slot The Rack Slot of the Rack Server.

Dell EMC Rack Server Details Service Tag The Service Tag of the Rack Server.

Dell EMC Rack Server Status State Settings The State Settings of the Rack Server.

Dell EMC Rack Server Status Status The Status of the Rack Server.

Dell EMC Rack Server Details System Batteries The System Batteries of the Rack Server.

Dell EMC Rack Server Status System Battery Relatives in Healthy State

The percentage of relatives of type system_battery whose status doesn't warrant creating an event.

Dell EMC Rack Server Status Temperature Probe Relatives in Healthy State

The percentage of relatives of type temperature_probe whose status doesn't warrant creating an event.

Dell EMC Rack Server Details Temperature Probes The Temperature Probes of the Rack Server.

Dell EMC Rack Server Memory Total Memory Device Size

The Total Memory Device Size of the Rack Server.

Dell EMC Rack Server Disk Total Physical Disk Available RAID

The Total Physical Disk Available RAID of the Rack Server.

Dell EMC Rack Server Disk Total Physical Disk Capacity

The Total Physical Disk Capacity of the Rack Server.

Dell EMC Rack Server Disk Total Physical Disk Used RAID

The Total Physical Disk Used RAID of the Rack Server.

Dell EMC Rack Server Details Total Power Supply The Total Power Supply of the Rack Server.

Dell EMC Rack Server Details Total Processor Cores The Total Processor Device Core Count of the Rack Server.

Dell EMC Rack Server Details Total Server Power The Total Server Power of the total_processorServer.

Dell EMC Rack Server Details Version The Version of the Rack Server.

Dell EMC Rack Server Status Voltage Probe Relatives in Healthy State

The percentage of relatives of type voltage_probe whose status doesn't warrant creating an event.

Dell EMC Rack Server Details Voltage Probes The Voltage Probes of the Rack Server.

Dell EMC Rack Server Details Host Name Host Name

Dell EMC System Battery

Details Chassis Index The Chassis Index of the Server Battery.

Dell EMC System Battery

Details Index The Index of the Server Battery.

Dell EMC System Battery

Details Server Battery Reading The Server Battery Reading of the Server Battery.

Management Pack for Dell EMC PowerEdge

VMware, Inc. 56

Page 57: EMC PowerEdge Management Pack for Dell - VMware

Resource Kind Resource Group Resource Attribute Attribute Type

Dell EMC System Battery

Status Server Battery Status The Server Battery Status of the Server Battery.

Dell EMC System Battery

Details Service Tag The Service Tag of the Server Battery.

Dell EMC Temperature Probe

Details Chassis Index The Chassis Index of the Temperature Probe.

Dell EMC Temperature Probe

Details Index The Index of the Temperature Probe.

Dell EMC Temperature Probe

Details Location The Location of the Temperature Probe.

Dell EMC Temperature Probe

Details Reading The Reading of the Temperature Probe.

Dell EMC Temperature Probe

Details Service Tag The Service Tag of the Temperature Probe.

Dell EMC Temperature Probe

Status Status The Status of the Temperature Probe.

Dell EMC Virtual Disk Details Available Protocols The Available Protocols of the Virtual Disk.

Dell EMC Virtual Disk Memory Bad Blocks Detected The Bad Blocks Detected of the Virtual Disk.

Dell EMC Virtual Disk Details Cache Policy The Cache Policy of the Virtual Disk.

Dell EMC Virtual Disk Disk Capacity The Virtual Disk Capacity of the Virtual Disk.

Dell EMC Virtual Disk Status Component Status The Component Status of the Virtual Disk.

Dell EMC Virtual Disk Details Fully Qualified Device Descriptor

The Fully Qualified Device Descriptor of the Virtual Disk.

Dell EMC Virtual Disk Details Layout The Layout of the Virtual Disk.

Dell EMC Virtual Disk Details Media Type The Media Type of the Virtual Disk.

Dell EMC Virtual Disk Details Name The Name of the Virtual Disk.

Dell EMC Virtual Disk Details Number The Number of the Virtual Disk.

Dell EMC Virtual Disk Status Operational State The Operational State of the Virtual Disk.

Dell EMC Virtual Disk Details Progress The Progress of the Virtual Disk.

Dell EMC Virtual Disk Details Read Policy The Read Policy of the Virtual Disk.

Dell EMC Virtual Disk Details Remaining Redundancy The Remaining Redundancy of the Virtual Disk.

Dell EMC Virtual Disk Details Service Tag The Service Tag of the Virtual Disk.

Dell EMC Virtual Disk Status State The Virtual Disk State of the Virtual Disk.

Dell EMC Virtual Disk Details Stripe Size The Stripe Size of the Virtual Disk.

Dell EMC Virtual Disk Details Write Policy The Write Policy of the Virtual Disk.

Dell EMC Voltage Probe

Details Chassis Index The Chassis Index of the Voltage Probe.

Dell EMC Voltage Probe

Details Discrete Reading The Discrete Reading of the Voltage Probe.

Management Pack for Dell EMC PowerEdge

VMware, Inc. 57

Page 58: EMC PowerEdge Management Pack for Dell - VMware

Resource Kind Resource Group Resource Attribute Attribute Type

Dell EMC Voltage Probe

Details Index The Index of the Voltage Probe.

Dell EMC Voltage Probe

Details Location The Location of the Voltage Probe.

Dell EMC Voltage Probe

Details Reading The Reading of the Voltage Probe.

Dell EMC Voltage Probe

Details Service Tag The Service Tag of the Voltage Probe.

Dell EMC Voltage Probe

Status Status The Status of the Voltage Probe.

Management Pack for Dell EMC PowerEdge

VMware, Inc. 58