emergency dimming luminaire control - leviton...product data leviton manufacturing co., inc....

4
PRODUCT DATA Leviton Mfg. Co., Inc. Lighting & Energy Solutions 20497 SW Teton Avenue, Tualatin, OR 97062 1-800-736-6682 Tech Line: 1-800-959-6004 Fax: 503-404-5594 www.leviton.com/les © 2013 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice. Emergency Dimming Luminaire Control Emergency Dimming Luminaire Control DESCRIPTION In the past, all designated emergency lights in a facility had to stay on 24 hours a day to meet safety codes. Now with Leviton Emergency Dimming Luminaire Control, you can specify and install a UL-924 listed emergency power control device that can convert and control up to 20 regular light fixtures as approved emergency lights. These emergency lights can then be turned ON and OFF in the same manner as regular lights. The Emergency Dimming Luminaire Control automatically illuminates connected emergency loads to full brightness upon utility power interruption, regardless of switch/dimmer position. Ideal for emergency luminaires in public places such as: Auditoriums Restaurants Conference rooms Theaters Classrooms Retail spaces Municipal buildings Houses of worship FEATURES Integral Test Switch provides convenient anytime testing Voltage Surge Protection ensures reliable performance under adverse conditions Status indicators separate LEDs indicate regular and emergency power, allowing verification of correct wiring connections Emergency Power Supervision—internal supervision circuits to prevent emergency luminaires from illuminating during normal times if Emergency Hot or Neutral conductors have been interrupted. This gives warning that a problem exists with emergency supply, which would otherwise be unnoticed, especially when controls are mounted above ceiling tile Triple Safety and Reliability—consists of 2 contactors, C-1 and C-2. - C-1 energized during normal times and is de-energized when regular power is interrupted - C-2 energized when regular power is interrupted and is de-energized when regular power is restored Automatically switches designated emergency fixtures from a dimming control to emergency power during a utility power interruption and brings them to full brightness Universal mounting—surface, above suspended ceiling or recessed Manual test switch 2-wire, 3-wire dimmable loads, including 0-10V, DALI and Lutron EcoSystem

Upload: others

Post on 14-Oct-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Emergency Dimming Luminaire Control - Leviton...PRODUCT DATA Leviton Manufacturing Co., Inc. Lighting & Energy Solutions 20497 SW Teton Avenue, Tualatin, OR 97062 • Tele: 1-800-736-6682

PRODUCT DATA

Leviton Mfg. Co., Inc. Lighting & Energy Solutions20497 SW Teton Avenue, Tualatin, OR 97062 1-800-736-6682 Tech Line: 1-800-959-6004 Fax: 503-404-5594 www.leviton.com/les© 2013 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice.

Emer

gen

cy D

imm

ing

Lum

inai

re C

ontr

ol

Emergency Dimming Luminaire Control

DESCRIPTION In the past, all designated emergency lights in a facility had to stay on 24 hours a day to meet safety codes. Now with Leviton Emergency Dimming Luminaire Control, you can specify and install a UL-924 listed emergency power control device that can convert and control up to 20 regular light fixtures as approved emergency lights. These emergency lights can then be turned ON and OFF in the same manner as regular lights.

The Emergency Dimming Luminaire Control automatically illuminates connected emergency loads to full brightness upon utility power interruption, regardless of switch/dimmer position. Ideal for emergency luminaires in public places such as:

• Auditoriums • Restaurants • Conference rooms • Theaters • Classrooms • Retail spaces • Municipal buildings • Houses of worship

FEATURES• Integral Test Switch provides convenient anytime testing • Voltage Surge Protection ensures reliable performance under adverse conditions• Status indicators separate LEDs indicate regular and emergency power, allowing verification of correct wiring connections• Emergency Power Supervision—internal supervision circuits to prevent emergency luminaires from illuminating during normal times if Emergency Hot or Neutral conductors have been interrupted. This gives warning that a problem exists with emergency supply, which would otherwise be unnoticed, especially when controls are mounted above ceiling tile

• Triple Safety and Reliability—consists of 2 contactors, C-1 and C-2. - C-1 energized during normal times and is de-energized when regular power is interrupted - C-2 energized when regular power is interrupted and is de-energized when regular power is restored• Automatically switches designated emergency fixtures from a dimming control to emergency power during a utility power interruption and brings them to full brightness• Universal mounting—surface, above suspended ceiling or recessed• Manual test switch• 2-wire, 3-wire dimmable loads, including 0-10V, DALI and Lutron EcoSystem

Page 2: Emergency Dimming Luminaire Control - Leviton...PRODUCT DATA Leviton Manufacturing Co., Inc. Lighting & Energy Solutions 20497 SW Teton Avenue, Tualatin, OR 97062 • Tele: 1-800-736-6682

PRODUCT DATAEm

erg

ency

Dim

min

g L

umin

aire

Con

trol

WIRING DIAGRAM TRANSFER CONTROL FOR 2 WIRE DIMMABLE LOADS WHEN USED WITH WALLBOX DIMMER

WIRING DIAGRAM TRANSFER CONTROL FOR 2 WIRE DIMMABLE LOADS WHEN USED WITH DIMMING PANEL

Page 3: Emergency Dimming Luminaire Control - Leviton...PRODUCT DATA Leviton Manufacturing Co., Inc. Lighting & Energy Solutions 20497 SW Teton Avenue, Tualatin, OR 97062 • Tele: 1-800-736-6682

Leviton Mfg. Co., Inc. Lighting & Energy Solutions20497 SW Teton Avenue, Portland, OR 97062 1-800-736-6682 Tech Line: 1-800-959-6004 Fax: 503-404-5594 www.leviton.com/les© 2013 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice.

Emer

gen

cy D

imm

ing

Lum

inai

re C

ontr

ol

WIRING DIAGRAM TRANSFER CONTROL FOR 3 WIRE DIMMABLE LOADS

WIRING DIAGRAM TRANSFER CONTROL FOR 4 WIRE DIMMABLE LOADS (0-10V & DIGITAL BALLASTS)

Page 4: Emergency Dimming Luminaire Control - Leviton...PRODUCT DATA Leviton Manufacturing Co., Inc. Lighting & Energy Solutions 20497 SW Teton Avenue, Tualatin, OR 97062 • Tele: 1-800-736-6682

PRODUCT DATA

Leviton Manufacturing Co., Inc. Lighting & Energy Solutions20497 SW Teton Avenue, Tualatin, OR 97062 • Tele: 1-800-736-6682 • FAX: 503-404-5594 • Tech Line (6:00AM-4:00PM P.S.T. Mon-Fri): 1-800-959-6004

Leviton Manufacturing Co., Inc. Global Headquarters201 N. Service Rd. Melville, NY 11747-3138 • Tech Line: 1-800-824-3005 • Fax: 1-800-832-9538

Leviton Manufacturing of Canada, Ltd.165 Hymus Boulevard, Pointe Claire, Quebec H9R 1E9 • Telephone: 1-800-469-7890 • FAX: 1-800-563-1853

Leviton S. de R.L. de C.V.Lago Tana 43, Mexico DF, Mexico CP 11290 • Tel. (+52) 55-5082-1040 • FAX: (+52) 5386-1797 • www.leviton.com.mx

Visit our Website at: www.leviton.com/les© 2013 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice.

LEVITON SPECIFICATION SUBMITTAL

JOB NAME: CATALOG NUMBERS:JOB NUMBER:

G-8962/E13-aa

Emer

gen

cy D

imm

ing

Lum

inai

re C

ontr

ol

ORDERING INFORMATIONCAT. NO. DESCRIPTION

ECD00-100Emergency Luminaire Control, dimming load transfer, 120V 60Hz, 20A ballast, general purpose, 1800W incandescent, 20A solid state/magnetic transformer

ECD00-200Emergency Luminaire Control, dimming load transfer, 277V 60Hz, 20A ballast, general purpose, 1500W incandescent, 20A solid state/magnetic transformer

ELECTRICAL

General Purpose 120V or 277V, 60Hz

Tungsten/Incandescent 120V, 1800W (15A), 60Hz

Ballast/Transformer 20A, 120V or 277V, 60Hz

High Voltage Surge Protection Up to 50,000V

Voltage Tolerance +/- 15%

PHYSICAL

Mounting Mounts inside a 4 11/16” (119.06mm) junction box with an extension and double-gang plaster ring

Dimensions Flush Mount Size: 6” (152.4mm)H x 6” (152.4mm)W x 0.25” (6.35mm)DBody Size: 4.25” (107.95mm)H x 4.25” (107.95mm)W x 1.5” (38.1mm)D

Weight 1 lb (0.45kg)

Ambient Temperature 32° - 140°F (0° - 60°C)

IP Rating IP20

Listings UL Listed to UL924, cUL/US

SPECIFICATIONS