Page 1: EMERGENCY LED DRIVERS ALIMENTATORI LED PER … · EMERGENCY LED DRIVERS ALIMENTATORI LED PER ILLUMINAZIONE D’EMERGENZA . ... intervento in emergenza. Weight - Peso gr. 118 Pcs -

TCI professional LED applications 233www.tci.it

LED

LED

Made in Europe

professional led applications

EMERGENCY LED DRIVERS

ALIMENTATORI LED PER ILLUMINAZIONE D’EMERGENZA

TCI professional LED applications www.tci.it 233

professional led applications

Page 2: EMERGENCY LED DRIVERS ALIMENTATORI LED PER … · EMERGENCY LED DRIVERS ALIMENTATORI LED PER ILLUMINAZIONE D’EMERGENZA . ... intervento in emergenza. Weight - Peso gr. 118 Pcs -

LED

LED

TCI professional LED applications234 www.tci.it

Made in Europe

professional led applications

Emergency light KIT for power LED and LED modules KIT per luce d’emergenza per power LED e moduli LED

ELDN T

Article Articolo

Code Codice

Battery BatteriaV - Ah

Autonomy Autonomia

h

Flux Flusso

%

ta°C

tc°C

ELDN T 123010 7,2 V - 1,6 Ah 1 70 - 100 % 0...+60 80ELDN T-3 123010/3 7,2 V - 4 Ah 3 70 - 100 % 0...+60 80

• Protetto in classe II contro le scosse elettriche per contatti diretti e indiretti. • Intervento istantaneo ad ogni mancanza di rete.• Funzionamento in sola emergenza o in luce continua (luce continua in abbinamento con alimentatori elettronici e alimentatori elettronici dimmerabili).• Regolazione con DIP-SWITCH, per power LED a corrente costante o per moduli LED a tensione costante. • Batterie al Ni-Cd “alta temperatura“.• Indicatore di ricarica a LED. • Dispositivo di protezione contro le scariche prolungate.• Possibilità d’inibizione in “modo riposo” con telecomando esterno centralizzato.Dati tecnici• Lunghezza cavo batteria: 280 mm.• Lunghezza cavo LED: 350 mm.• Foro di montaggio LED: Ø 9 mm.• Corrente di alimentazione: 20 mA max.• Portata morsettiera: 1,5 mm2.• Distanza massima dall’alimentatore dalla lampada: 2 metri. Batterie: I KIT d’emergenza TCI sono dotati di batterie ricaricabili Ni-Cd ad alta temperatura. Le batterie, speciali per sistemi di emergenza, sopportano una carica permanente per almeno 4 anni, in ambienti ad alte temperature (fino a +50°C).• Corrente costante durante la carica. • Zero manutenzione.• Ciclo di vita superiore a 500 ricariche. • Lungo periodo di stoccaggio (fino a 4 mesi in condizioni normali: da +5°C a +25°C con umidità relativa del 65 % ±5 %). Il KIT include la batteria, è possibile acquistare separatamente sia la batteria che l’alimentatore.

• Class II protection against electric shock for direct or indirect contact. • Instant emergency operation at mains failure.• Maintained or not maintained operation (maintained operation suitable with electronic drivers or dimmable electronic drivers).• Multi-power dimmable version DIP-SWITCH, constant current or constant voltage to power LED to LED modules. • “High temperature” Ni-Cd batteries.• Charge indicator with LED.• Protection device against extensive discharge.• ”Rest mode” facility with remote control device.Technical data• Length battery cable: 280 mm.• Length LED cable: 350 mm.• LED mounting hole: Ø 9 mm.• Supply current: 20 mA max.• Terminal blocks max. connection size: 1,5 mm2. • Max distance between driver and lamp: 2 meters.Battery:All Emergency lighting KITS TCI are provided with rechargeable high temperature Ni-Cd batteries.These cells accept a permanent charge for a minimum of 4 years in high-temperature environments (up to +50°C) such as security lighting equipment. • Constant current during charge.• Zero maintenance.• Long cycle life (over 500 charge discharge cycles). • Long term storage (up to 4 months in normal conditions: temperature range from +5°C to +25°C in a 65 % ±5 % relative humidity atmosphere). The kit includes the battery, you can purchase only the battery and power supply.

Battery Battery caseCode Codice

ELDN T ELDN T-3signal LED

LED segnalazione7,2 V - 1,6 Ah

compact - comaptti

7,2 V - 4 Ahcompact - compatti

2x 3,6 V - 4 Ahlinear - lineare

BOX 1h BOX 3h

123010 3 3 3123010K 3 3 3 3123010/3 3 3 3123010/3K 3 3 3 3123010NB 3 3123010/3NB 3 3Battery - BatterieCode Codice

7,2 V - 1,6 Ah compact - comaptti

7,2 V - 4 Ahcompact - comaptti

2x 3,6 V - 4 Ahlinear - lineare

BOX 1h BOX 3h

480550189 3480550190 3480550187 3123009/172 3 3123009/372 3 3

Voltage Tensione 220 - 240 V

Frequency Frequenza 50...60 Hz

Potenza Power 3 - 7 W

Supply current Corrente di alimentazione: 20 mA

Operating time Autonomia: 1-3 h

Charge time Tempo di ricarica: 24 h

Reference Norms Norme di riferimento: EN 55015 EN 60598-2-22EN 61000-3-2 EN 61347-2-13EN 61347-2-7EN 61547

Lamps Lampade:LAMPADE LED 12 V 12 V LED LAMPS

Lamp cap Attacco lampada:GU 5,3

SELV

Page 3: EMERGENCY LED DRIVERS ALIMENTATORI LED PER … · EMERGENCY LED DRIVERS ALIMENTATORI LED PER ILLUMINAZIONE D’EMERGENZA . ... intervento in emergenza. Weight - Peso gr. 118 Pcs -

TCI professional LED applications 235www.tci.it

LED

LED

Made in Europe

professional led applications

7,2 V - 1,6 Ah - code - codice 123009/172 ta=0÷50°C

33

40200212

+

2 x 3,6 V - 4 Ah - code - codice 480550187 - ta=0÷50°C

DIP-SWITCH Working voltage during emergency (VL)

Tensione di lavoro in emergenza (VL)

Output current during emergency (I)

Corrente in uscita in emergenza (I)

n° LED max.

Power max. for LED modules

Potenza max. per moduli LED

A 9...12 V 350 ± 10% 3/4 24 W

B 9...24 V 350...250mA 7/8 30 W

C 9...46 V 350...125mA 12/14 -

D 9...58 V 350...100mA 17/18 -

Emergency light KIT for power LED and LED modules KIT per luce d’emergenza per power LED e moduli LED

ELDN T

Wiring diagrams - Schemi di collegamento

DRIVER

_+

N1

N

L1

LED indicatorCHARGE

LED/LOAD

Battery

L

LN

in out

Rest mode4÷12 Vdc

+_

--

�12

NO

+_

+

+

+

_

_

_

Battery

LED/LOAD

Rest mode4÷12 Vdc

LED indicator12 --

NLCHARGE

NO

+_

+_

_

_

_+

+

+

Maintained with external electronic driver diagram Collegamento permanente (illuminazione ordinaria)

Non-maintained (emergency only) diagram Collegamento non permanente (solo emergenza)

+_

+_

ELDN T

TELECOMANDOINIBIZIONE

REST MODE

Remote control device It allows both to switch off the emergency lamps during emergency mode. The rest mode is automatically resetted when mains voltage is restored. This remote control device can be installed so as to operate several emergency units at the same time. Con telecomando esterno centralizzato Permette lo spegnimento delle lampade durante il funzionamento in emer-genza. Al rientro della tensione di rete il sistema si predisporrà ad un nuovo intervento in emergenza.

Weight - Peso gr. 118Pcs - Pezzi 1Ø56

46

34

166

150 135

23

45 59

29,5

24,5

185

Ø65

77

39,5

24,5

245

7,2 V - 4 Ah - code - codice 123009/372 ta=0÷50°C

198

33

65

Ø88

0,0 10,0 20,0 30,0 40,0 50,0 60,0 70,00

50

100

150

200

250

300

350

400

450ELDN T

Remote control device diagrams Collegamento con telecomando esterno centralizzato

Page 4: EMERGENCY LED DRIVERS ALIMENTATORI LED PER … · EMERGENCY LED DRIVERS ALIMENTATORI LED PER ILLUMINAZIONE D’EMERGENZA . ... intervento in emergenza. Weight - Peso gr. 118 Pcs -

LED

LED

TCI professional LED applications236 www.tci.it

Made in Europe

professional led applications

Emergency light KIT for 12 Vdc LED lamps with cap GU 5,3 KIT per luce d’emergenza per lampade LED 12 Vdc con attacco GU 5,3

ELBT

Article Articolo

Code Codice

W Lamp Lampada

Battery BatteriaV - Ah

Autonomy Autonomia

h

Flux Flusso

%

ta°C

tc°C

ELBT 123013 3 - 7 GU 5,3 7,2 V - 1,6 Ah 1 80 / 100 % 0...+50 70ELBT-3 123013/3 3 - 7 GU 5,3 7,2 V - 4 Ah 3 80 / 100 % 0...+50 70

• Utilizzabile per apparecchi di illuminazione in classe di protezione I e II.• Intervento istantaneo ad ogni mancanza di rete.• Funzionamento in sola emergenza o in luce continua.• Adatto a lampade LED 12 Vdc (0 Hz). • Elevato rendimento con minima dispersione di calore ed assoluta affidabilità nel tempo. • Batterie al Ni-Cd “alta temperatura“.• Indicatore di ricarica a LED. • Dispositivo di protezione contro le scariche prolungate.Dati tecnici• Lunghezza cavo batteria: 280 mm.• Lunghezza cavo LED: 350 mm.• Foro di montaggio LED: Ø 9 mm.• Corrente di alimentazione: 20 mA max.• Portata morsetti ad innesto rapido: 1,5 mm2.• Distanza massima dall’alimentatore dalla lampada: 2 metri. Batterie: I KIT d’emergenza TCI sono dotati di batterie ricaricabili Saft Ni-Cd ad alta temperatura. Le batterie, speciali per sistemi di emergenza, sopportano una carica permanente per almeno 4 anni, in ambienti ad alte temperature (fino a +50°C).• Corrente costante durante la carica. • Zero manutenzione.• Ciclo di vita superiore a 500 ricariche. • Lungo periodo di stoccaggio (fino a 4 mesi in condizioni normali: da +5°C a +25°C con umidità relativa del 65 % ±5 %).Il KIT include la batteria, è possibile acquistare separatamente sia la batteria che l’alimentatore.

• It can be used for lighting equipment in protection class I and II.• Instant emergency operation at mains failure.• Maintained or not maintained operation.• Suitable for LED lamps 12 Vdc (0 Hz). • High efficiency, minimum heat dispersion and absolute reliability.• “High temperature” Ni-Cd batteries.• Charge indicator with LED.• Protection device against extensive discharge.Technical data• Length battery cable: 280 mm.• Length LED cable: 350 mm.• LED mounting hole: Ø 9 mm.• Supply current: 20 mA max.• Push-wire connections max. size: 1,5 mm2. • Max distance between driver and lamp: 2 meters.Battery:All Emergency lighting KITS TCI are provided with rechargeable high temperature Ni-Cd Saft batteries.These cells accept a permanent charge for a minimum of 4 years in high-temperature environments (up to +50°C) such as security lighting equipment. • Constant current during charge.• Zero maintenance.• Long cycle life (over 500 charge discharge cycles). • Long term storage (up to 4 months in normal conditions: temperature range from +5°C to +25°C in a 65 % ±5 % relative humidity atmosphere).The kit includes the battery, you can purchase only the battery and power supply.

280300

2425

7,2 V - 1,6 Ah - Weight - Peso 300 gr. code - codice 480550188

33

40200212

+

7,2 V - 4 Ah - Weight - Peso 840 gr. code - codice 2x 480550187 + 1x 485720340

Voltage Tensione 220 - 240 V

Frequency Frequenza 50...60 Hz

Potenza Power 3 - 7 W

Supply current Corrente di alimentazione: 20 mA

Operating time Autonomia: 1-3 h

Charge time Tempo di ricarica: 24 h

Reference Norms Norme di riferimento: EN 55015 EN 60598-2-22EN 61000-3-2 EN 61347-2-13EN 61347-2-7EN 61547

Lamps Lampade:LAMPADE LED 12 Vdc 12 Vdc LED LAMPS

Lamp cap Attacco lampada:GU 5,3

Page 5: EMERGENCY LED DRIVERS ALIMENTATORI LED PER … · EMERGENCY LED DRIVERS ALIMENTATORI LED PER ILLUMINAZIONE D’EMERGENZA . ... intervento in emergenza. Weight - Peso gr. 118 Pcs -

TCI professional LED applications 237www.tci.it

LED

LED

Made in Europe

professional led applications

Emergency light KIT for 12 Vdc LED lamps with cap GU 5,3 KIT per luce d’emergenza per lampade LED 12 Vdc con attacco GU 5,3

ELBT

140

150

30

41

Wiring diagrams - Schemi di collegamento

GU 5,3 LED LAMP12 Vdc

BATT.

_+

LN

CHARGE

P

LED

+_

GU 5,3 LED LAMP12 Vdc

BATT.

_+

12 V

LNCHARGE

L1

N1

P

LED

+_

Non-maintained (emergency only) diagram - Collegamento non permanente (solo emergenza)

Maintained with external electronic driver diagram - Collegamento permanente (illuminazione ordinaria)

Weight - Peso gr. 170Pcs - Pezzi 1

+_

RESTMODE

EMERGENCY

INHIBITION REMOTE CONTROL

+_

Battery replacementSealed Ni-Cd batteries. To replace batteries follows the instructions. Do not discard in the environment. Return to manufacturer.Sostituzione della batteriaBatterie ermetiche al Ni-Cd. Per la sostituzione estrarre il connettore come indi-cato in figura. Non disperdere nell’ambiente, riporre negli appositi contenitori.

REMOTE CONTROL DEVICEit allows both to switch off and switch on the emergency lampsduring emergency mode. The rest mode is automatically resetted when mains voltage is restored. This remote control device can be installed so as to operate several emergency units at the same time.CON TELECOMANDO ESTERNO CENTRALIZZATOPermette sia lo spegnimento che la riaccensione delle lampade durante il funzionamento in emergenza. Al rientro della tensione di rete il sistema si predisporrà ad un nuovo intervento in emergenza.

Remote control device diagrams Collegamento con telecomando esterno centralizzato

Page 6: EMERGENCY LED DRIVERS ALIMENTATORI LED PER … · EMERGENCY LED DRIVERS ALIMENTATORI LED PER ILLUMINAZIONE D’EMERGENZA . ... intervento in emergenza. Weight - Peso gr. 118 Pcs -

LED

LED

TCI professional LED applications238 www.tci.it

Made in Europe

professional led applications

Emergency light KIT for 230 Vdc LED lamps with cap GU 10 KIT per luce d’emergenza per lampade LED 230 Vdc con attacco GU 10

ELHT

• Utilizzabile per apparecchi di illuminazione in classe di protezione I e II. • Intervento istantaneo ad ogni mancanza di rete.• Funzionamento in sola emergenza o in luce continua (luce continua in abbinamento con alimentatori elettronici e alimentatori elettronici dimmerabili).• Adatto a lampade LED 230 Vdc (0 Hz). • Elevato rendimento con minima dispersione di calore ed assoluta affidabilità nel tempo. • Batterie al Ni-Cd “alta temperatura“.• Indicatore di ricarica a LED. • Dispositivo di protezione contro le scariche prolungate.• Possibilità d’inibizione in “modo riposo” con telecomando esterno centralizzato.Dati tecnici• Lunghezza cavo batteria: 280 mm.• Lunghezza cavo LED: 350 mm.• Foro di montaggio LED: Ø 9 mm.• Corrente di alimentazione: 20 mA max.• Portata morsetti ad innesto rapido: 1,5 mm2.• Distanza massima dall’alimentatore dalla lampada: 2 metri. Batterie: I KIT d’emergenza TCI sono dotati di batterie ricaricabili Saft Ni-Cd ad alta temperatura. Le batterie, speciali per sistemi di emergenza, sopportano una ca-rica permanente per almeno 4 anni, in ambienti ad alte temperature (fino a +50°C).• Corrente costante durante la carica. • Zero manutenzione.• Ciclo di vita superiore a 500 ricariche. • Lungo periodo di stoccaggio (fino a 4 mesi in condizioni normali: da +5°C a +25°C con umidità relativa del 65 % ±5 %).Il KIT include la batteria, è possibile acquistare separatamente sia la batteria che l’alimentatore.

• It can be used for lighting equipment in protection class I and II. • Instant emergency operation at mains failure.• Maintained or not maintained operation (maintained operation suitable with electronic drivers and dimmable electronic drivers).• Suitable for LED lamps 230 Vdc (0 Hz). • High efficiency, minimum heat dispersion and absolute reliability. • “High temperature” Ni-Cd batteries.• Charge indicator with LED.• Protection device against extensive discharge.• ”Rest mode” facility with remote control device.Technical data• Length battery cable: 280 mm.• Length LED cable: 350 mm.• LED mounting hole: Ø 9 mm.• Supply current: 20 mA max.• Push-wire connections max. size: 1,5 mm2. • Max distance between driver and lamp: 2 meters.Battery:All Emergency lighting KITS TCI are provided with rechargeable high temperature Ni-Cd Saft batteries.These cells accept a permanent charge for a minimum of 4 years in high-temperature environments (up to +50°C) such as security lighting equipment. • Constant current during charge.• Zero maintenance.• Long cycle life (over 500 charge discharge cycles). • Long term storage (up to 4 months in normal conditions: temperature range from +5°C to +25°C in a 65 % ±5 % relative humidity atmosphere).The kit includes the battery, you can purchase only the battery and power supply.

280300

2425

7,2 V - 1,6 Ah - Weight - Peso 300 gr. code - codice 480550188

Article Articolo

Code Codice

W Lamp Lampada

Battery BatteriaV - Ah

Autonomy Autonomia

h

Flux Flusso

%

ta°C

tc°C

ELHT 123012 3 - 8,5 GU 10 7,2 V - 1,6 Ah 1 80 / 100 % 0...+50 70ELHT-3 123012/3 3 - 8,5 GU 10 7,2 V - 4 Ah 3 80 / 100 % 0...+50 70

33

40200212

+

7,2 V - 4 Ah - Weight - Peso 840 gr. code - codice 2x 480550187 + 1x 485720340

Voltage Tensione 220 - 240 V

Frequency Frequenza 50...60 Hz

Power Potenza 3 - 8,5 W

Supply current Corrente di alimentazione: 20 mA

Operating time Autonomia: 1-3 h

Charge time Tempo di ricarica: 24 h

Reference Norms Norme di riferimento: EN 55015 EN 60598-2-22EN 61000-3-2 EN 61347-2-13EN 61347-2-7EN 61547

Lamps Lampade:LAMPADE LED 230 Vdc 230 Vdc LED LAMPS

Lamp cap Attacco lampada:GU 10

Page 7: EMERGENCY LED DRIVERS ALIMENTATORI LED PER … · EMERGENCY LED DRIVERS ALIMENTATORI LED PER ILLUMINAZIONE D’EMERGENZA . ... intervento in emergenza. Weight - Peso gr. 118 Pcs -

TCI professional LED applications 239www.tci.it

LED

LED

Made in Europe

professional led applications

140

150

30

41

Emergency light KIT for 230 Vdc LED lamps with cap GU 10 KIT per luce d’emergenza per lampade LED 230 Vdc con attacco GU 10

ELHT

GU 10 LED LAMP230÷240 VdcL

N

BATT.

_+

CHARGE

P

LED

+ _

GU 10 LED LAMP230÷240 Vdc

BATT.

_+

LNCHARGE

L1

N1

P

LED

+_

Wiring diagrams - Schemi di collegamento

Non-maintained (emergency only) diagram - Collegamento non permanente (solo emergenza)

Maintained with external electronic driver diagram - Collegamento permanente (illuminazione ordinaria)

Weight - Peso gr. 170Pcs - Pezzi 1

Battery replacementSealed Ni-Cd batteries. To replace batteries follows the instructions. Do not discard in the environment. Return to manufacturer.Sostituzione della batteriaBatterie ermetiche al Ni-Cd. Per la sostituzione estrarre il connettore come indi-cato in figura. Non disperdere nell’ambiente, riporre negli appositi contenitori.

+_

RESTMODE

EMERGENCY

INHIBITION REMOTE CONTROL

+_

REMOTE CONTROL DEVICEit allows both to switch off and switch on the emergency lampsduring emergency mode. The rest mode is automatically resetted when mains voltage is restored. This remote control device can be installed so as to operate several emergency units at the same time.CON TELECOMANDO ESTERNO CENTRALIZZATOPermette sia lo spegnimento che la riaccensione delle lampade durante il funzionamento in emergenza. Al rientro della tensione di rete il sistema si predisporrà ad un nuovo intervento in emergenza.