emerging hyphenated and comprehensive multi-dimensional … · 2020. 6. 13. · 23478-pecdf pcdd/f...

99
Emerging Hyphenated and Comprehensive Multi-Dimensional Techniques for the Measurement of POPs in Food J.-F. Focant Mass Spectrometry Laboratory Biological and Organic Analytical Chemistry

Upload: others

Post on 21-Jan-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Emerging Hyphenated and Comprehensive Multi-Dimensional Techniques for the Measurement of

POPs in Food

J.-F. Focant

Mass Spectrometry LaboratoryBiological and Organic Analytical Chemistry

Page 2: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Persistent Organic Pollutants

9 agrochemicals:-Aldrin -Chlordane-DDT -Dieldrin-Endrin -Heptachlor-HCB -Mirex-Toxaphene

3 industrial substances:-PCBs-PCDDs-PCDFs

POPs

Page 3: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Target Analytes2,3,7,8-substituted PCDDs (7)2,3,7,8-substituted PCDFs (10)Non-ortho PCBs (4)Mono-ortho PCBs (8)EU marker ‘Tracer’ PCBs (6)‘Biomonitoring’ PCBs (30)Selected OCPs (12)Selected PBDEs ? (8)

… Σ = 80+

TEFs

Page 4: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Contributors to human intake

FishMeatMilk

PCDD/Fs + NO-PCBs

35 %32 %

33 %

Target Matrices

Animal feedingstuffsHuman specimen

Belgium 2001 (Focant et al., 2002)

Page 5: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

EU Directive 1881/2006 ECEU Directive 1883/2006 EC EURACHEM Guide ‘The fitness for purpose of analytical methods’

QA/QC Guidelines

Requirements for analytical procedures:-Sensitivity (LOQs) -Selectivity-Accuracy -Trueness-Robustness -13C-labeled IS-Recovery rates -Separation: ’should be sufficient’

Page 6: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Requirements for analytical procedures– High sensitivity: low MDLs– High selectivity: distinction for PCDDs, PCDFs and

DL-PCBs from co-extracted and interfering compounds

– High accuracy: provide a valid estimate of the true concentration

– Trueness: +/- 20 % and CV< 15%– 13C-labeled IS: addition of PCDD/F and DL-PCB– Recovery rates: 60-120 % (30 - 140 %)– GC separation: “should be sufficient”– Lower - Upperbound: 20 % difference (in the

range of 1 pg/g fat for food)

EU Directive 1883/2006 EC

Page 7: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

The Dream

Time Cost Problems

0 0 0

0€101h

Sample

Congener-specific Results

Page 8: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Dreams Sometimes Come True

1886

1970’s

Page 9: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Area of EffortsReducing manual handlingIncreasing sample throughput (# analytes)Increasing analytical speedDecreasing blank levels (improve LOQs)Get a better position in The Triangle

Speed(Low cost)

Selectivity

Sensitivity

Page 10: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

POP Analysis SkeletonLLE, Soxhlet, SFE, MAE, SPME,SPE, MSPD, SBSE, PLE, …Extraction

Prep. LC (Silica), HPLC, SEC (GPC), …

Florisil, Alumina, Carbon, PYE, …

GC, GC-GC, GCxGC, …

Sector HRMS, QISTMSn, TOFMS, µECD,EIAs, RBAs, …

Clean-up

Fractionation

Separation

Measurement

Page 11: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion
Page 12: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Coupling (Instrumental)SPME-GC-MS SBSE-GC-MSSFE-GC-MS

Limited efficiencyfor Dioxins

SPE(or PLE)-Prep.LC-GC-IDMS(or RBA)

Liquids Solids SilicaAluminaCarbon

Automated

Page 13: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

ECF Integrated Approach

Time Cost Problems

0 0 0

0.5€4000.5dayGC-MS

AutomatedSPE or PLE

Automated MCLCClean-up System

Samples

Batches of 5-10 samples

Page 14: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Fluid Samples

Sample homogenisation

Spiking, proteins precipitation, ...

SPE (C18) extraction

Side ‘lipid percent’ determination

Clean-up

Page 15: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Reverse Phase

Non-polar phase (C18)Polar solvent (MeOH, …)

Selective retention of the analytes

SPE SchematicSolvated bonded silica

SiO

SiO

Si

O OH O

C18 C18

Solvated bonded silica

SiO

SiO

Si

O OH O

C18 C18

Page 16: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

PumpGauge

Nitrogentank

C18

Silica

Aqueous waste

1 2 3 4

Sample

1. Hexane2. Hexane-Dichloromethane (1:1)3. Ethyl acetate-Toluene (1:1)4. Toluene

1 2 3 4

1. Water2. Acetonitrile3. Hexane-Dichloromethane (1:1)4. Air

Carbon

Organic waste

1

1. PCDD/Fs & cPCBs

ECF Integrated System (liquids)

GC-MSIn parallel, 2 h/batch

Page 17: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

SPE

Si Al

C

Milk

Extractfor GC-MS

Page 18: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

0.0

0.5

1.0

1.5

2.0

2.5

3.0

2,3,7,

8 TCDD

1,2,3,

7,8 PeC

DD1,2

,3,4,7

,8 HxC

DD

1,2,3,

6,7,8

HxCDD

1,2,3,

7,8,9

HxCDD

2,3,7,

8 TCDF

1,2,3,

7,8 PeC

DF2,3

,4,7,8

PeCDF

1,2,3,

4,7,8

HxCDF

1,2,3,

6,7,8

HxCDF

2,3,4,

6,7,8

HxCDF

pg g

-1 m

ilk p

owde

r

SoxhletManual SPEIntegrated SPE

Accuracy (milk CRM)

Page 19: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Serum QC Chart

0.15

0.17

0.19

0.21

0.23

0.25

0.27

0.29

0.31

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30

Run number

Con

cent

ratio

n (p

gTEQ

/g)

PCDD/FsManual SPEIntegrated SPE

Page 20: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

(semi)Solid Samples

Sample homogenisation (liquid N2)

Freeze-drying (overnight)

Grinding

Spiking, PLE extraction

Side ‘lipid percent’ determination

Clean-up

Page 21: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Pressurized Liquid Extraction

Na2SO4

Cryo-homogenizationDrying (lyoph, …)120°C, 1500 psiHexane (others)Static and/or dynamic

10-30 min/sample

Page 22: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Na2SO4

Z

PLE Options Z Fat retainer (H2SO4-Si)

Several groups reported the use of H2SO4-Si to remove part of the lipids directly inside the extraction cell.

BUT:- Restricted to few extraction solvents- H2SO4-Si very ‘strong’ in conditions

like 120°C/1500 psi

Page 23: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion
Page 24: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

100ml &nitrogen

On-lineevaporation

20mlsharp pulse

ECF Integrated System (solids)

In parallel, 1.5 h/batch (5-10)

Page 25: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

CARP-1 CRM

PCDD/F concentrations

I-PCB concentrations0

2

4

6

8

10

12

14

16

2,3,7,

8-TeC

DD1,2

,3,7,8

-PeC

DD1,2

,3,4,7

,8-HxC

DD1,2

,3,6,7

,8-HxC

DD1,2

,3,7,8

,9-HxC

DD1,2

,3,4,6

,7,8-HpC

DD

OCDD2,3

,7,8-T

eCDF

1,2,3,

7,8-P

eCDF

pg /g

fw

ReferenceMeasured n=2

0

20000

40000

60000

80000

100000

120000

140000

160000

180000

200000

PCB 52

PCB 101/90

PCB 105

PCB 118PCB 138

/163/16

4

PCB 153

PCB 180

pg/g

fwReferenceMeasured n=2(Sample size = 4g)

Referen

ceMea

sured

Truen

ess (

%)

SUM PCDD/Fs 13.3 12.6 -5.3SUM PCBs 60.3 66.2 9.8SUM PCDD/Fs+PCBs 73.6 78.8 7.1pgTEQ/g f.w.

Page 26: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

How to Measure ?SPE(or PLE)-Prep.LC ??

Liquids Solids Si, Al, C

On-line and Automated

One needs extra dimensionsChromatography, Spectroscopy, …

GC & MS

Sample Dimensionality System Dimensionality

Page 27: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Reference Method(HR)GC-IDHRMS ISO-17025 PTV-LVI-GC-IDQISTMS/MS alternative method

Thermo MAT95 XP Micromass AuSpec Ultima

Could we better match sample dimensionality ?

Separate injectionsDifferent GC phases- PCDD/Fs [RTX-5MS] - PCBs [HT-8]- PBDEs [STX-500]

Thermo Polaris Q

Page 28: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Dimensionality

GC-µECD

GCxGC-µECDGCxGC-TOFMS

Page 29: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

GCxGC

Comprehensive two-dimensionnal gas chromatography

Peak capacity enhancer

Page 30: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

“Two-dimensional (2D) separations are those techniques in which a sample is subject to two independent (orthogonal) displacement processes”

J. C. Giddings, Anal. Chem. 56 (1984) 1258A-1270A.

Definition of ‘Two-dimensional’

Page 31: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Definition of ‘Comprehensive’

A two-dimensional separation can be called comprehensive if:

1. Every part of the sample is subjected to two independent separative displacements.

Orthogonality rule

2. The separation (resolution) obtained in the first dimension is preserved throughout the process.

Conservation rule

Page 32: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Orthogonality Rule

VolatilityPolarity

Page 33: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

OK KO

Conservation Rule

Page 34: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Peak capacity = = 50 peaks

Classical GC

… …

Injector Detector

30m x 0.25mm x 0.25µm

Page 35: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Injector

1st dimension 2nd dimension

Detector

GCxGC

Column 1 Column 230m x 0.25mm x 0.25µm 2m x 0.25mm x 0.25µm

Page 36: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

GCxGC (2 columns)… …

1D = 30 m2D = 2 m

Peak capacity = 1Dnc x 2Dnc= 50 x 19 = 950 peaks

[tTOT GCxGC = tTOT classical GC]

Page 37: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Splitless

1D RTX-500 40m0.18mm ID x 0.11µm df

2D BPX-50 1.5m0.10mm ID x 0.10µm df

LN2-Quad-jetsModulator

TOFMS

1TtR ~ 50 min

PM = 4 sec

Instrumental Setup

Page 38: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Injector

1st dimension

LN2 supplier

Trapping

Detector

1st Oven

2nd dimension2nd Oven

Page 39: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Detector

1st dimension

LN2 supplier

Releasing

2nd dimension2nd Oven

1st Oven

Injector

Page 40: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

1st dimension

LN2 supplier

Refocusing

Detector

2nd dimension2nd Oven

1st Oven

Injector

Page 41: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

1st dimension

LN2 supplier

Injection into second dimension

Detector

1st Oven

2nd dimension2nd Oven

Injector

Page 42: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion
Page 43: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

2nd Oven

Modulator

Page 44: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion
Page 45: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Modulation ProcessSampling rate 0.25 Hz

1st Dim tR

2nd Dim tR

4 seconds

Each ‘ slice ’ is a separate seconddimension chromatogram

Page 46: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Signal at the Detector

Signal4 sec

Time15222

15200

15240

15262

15280

15302

15320

15342

15360

Page 47: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Displaying the Data

Contour Plot

2nd Dim tR (4 sec)

1st Dim tR

Signal

3D Plot

Page 48: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

3D Plot

1st Dim tR

2nd Dim tR

Contour Plot

1st Dim tR

2nd Dim tR

Page 49: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion
Page 50: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion
Page 51: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion
Page 52: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion
Page 53: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion
Page 54: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion
Page 55: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion
Page 56: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion
Page 57: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion
Page 58: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion
Page 59: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Why TOFMS ?

ScanningMS

SIM

Full Scan

–Comprehensive mass analysis–Slow

–Selective mass analysis–Fast

TOFNon-scanningMS

–Comprehensive mass analysis–Fast

(HRMS, QISTLRMS²)

Simultaneous samplingIon ratio remains constant across peaksSpectral continuity

Deconvolution

Page 60: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Specific Identification

Brunnée, Int. J. Mass Spectrom. (1987) 76 (2) 125.

Ideal Mass Analyzer ?

Page 61: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Time Compression

10 scans/s

TOF up to 500 scans per sec Scanning quad 2-5 scans per sec...

200 scans/s

200 ms peak

Page 62: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Coelution Solving Power

GCxGC TOFMS

Coelution

Peak capacity Deconvolution

Separation

Chromatographicresolution

Analyticalresolution

Page 63: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Symbiotic Relation

- TOFMS is the detector of choice to describe narrow 2D GCxGC peaks

&

- GCxGC zone compression enhances TOFMSsensitivity

Page 64: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Comprehensive Multidimensionality

1st Dim.GC

2nd Dim.GC

3rd Dim.TOFMS

ThermalModulation

IonisationModulation

Volatility Polarity Mass

OrthogonalityMinutes Seconds MilisecondsTime

scale

Page 65: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

PCDD/PCDFs and Planar-PCBs

1tR (s)CB-80

CB-77

CB-81

CB-126

CB-169

12378-PeCDD

12378-PeCDF23478-PeCDF

123478-HxCDF

123678-HxCDF

234678-HxCDF

123789-HxCDF

123478-HxCDD

123678-HxCDD123789-HxCDD

1234678-HpCDF

1234789-HpCDF

1234678-HpCDD

OCDF

OCDD

2378-TCDF

2378-TCDD

1234-TCDD

2tR (s)

Page 66: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

WHO and Tracer PCBs

2tR (s)

1tR (s)

CB-123

CB-118

CB-114

CB-105

CB-167

CB-156CB-157

CB-189

CB-170

CB-101

CB-28

CB-52

CB-153

CB-138 CB-180

Page 67: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

2000 4000 6000 80000

1

2

3

1tR

2tR

2000 4000 6000 80000

1

2

3

1tR

2tR

C12H9ClC12H9ClC12H8Cl2C12H8Cl2

C12H7Cl3C12H7Cl3C12H6Cl4C12H6Cl4

C12H5Cl5C12H5Cl5

C12H4Cl6C12H4Cl6

C12H3Cl7C12H3Cl7

C12H2Cl8C12H2Cl8

C12HCl9C12HCl9

209 PCBs (HT-8/BPX-50 Set)

C12Cl10

1tR (s)

2tR (s)

196 congeners separatedin 150 min

Page 68: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

The 3 Dimensions are Needed2Intensity

CB-132

CB-179

CB-1612IntensityIntensity

CB-132

CB-179

CB-161

CB-161CB-179

CB-132

1tR

2tRCB-161CB-179

CB-132

1tR

CB-161CB-179

CB-132

1tR1tR

2tR C

B

A

B

C

D

E

Page 69: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Isotope Dilution (13C12-Labels)Area = 1+2+3+4 (12C & 13C)

1

2

3

4

NativeLabeled

Page 70: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

23478-PeCDF

PCDD/F Calibration

Standard Area Certified Calculated Response Expected Calculated Ion Ratio Concentration Concentration Factor Ion Ratio Ion Ratio Result

CDC-07:1 6078 5 4.8 0.97 0.654 0.615 PassedCDC-08:1 9121 7.5 7.5 1.01 0.654 0.643 PassedCDC-06:1 3005 2 2.0 1.01 0.654 0.717 PassedCDC-05:1 1420 1 1.0 0.98 0.654 0.663 PassedCDC-04:1 218 0.5 0.5 0.99 0.654 0.612 PassedCDC-03:1 379 0.2 0.3 1.59 0.654 0.649 Passed

Page 71: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

0.20 pg 12C-2,3,7,8-TCDF

50 pg 13C-2,3,7,8-TCDF

Sensitivity

1 µl injected SL

Quan S/N = 10Area = 350

Page 72: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Quality Control Charts

BDE-47

BDE-100

CB-153

Page 73: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

‘Cleaned’ Fish Extract

CB-80 recovery std (0.5 ng)

Page 74: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Tracer PCBs in Fish

1.5g sample sizeRSD GCxGC-TOFMS: 1-14%RSD GC-HRMS: 3-5%RSD GC-MS/MS: 2-5%

N = 6

0

1000

2000

3000

4000

5000

6000

7000

TriCB-28 TeCB-52 PeCB-101 HxCB-138 HxCB-153 HpCB-180

pg/g

fw

GCxGC-TOFMSGC-HRMSGC-MS/MS

Page 75: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Non- and Mono-ortho PCBs in Fish

N = 6

15g sample size

0

500

1000

1500

2000

2500

PeC

B-1

05

PeC

B-1

18

pg/g

fw

0

50

100

150

200

250

300

PeC

B-1

14

PeC

B-1

23

HxC

B-1

56

HxC

B-1

57

HxC

B-1

67

HpC

B-1

89

TeC

B-77

GCxGC-IDTOFMSGC-IDHRMSGC-IDQISTMS/MS

0

2

4

6

8

10

12

14

16

TeC

B-81

PeC

B-1

26

HxC

B-1

69

0

500

1000

1500

2000

2500

PeC

B-1

05

PeC

B-1

18

pg/g

fw

0

50

100

150

200

250

300

PeC

B-1

14

PeC

B-1

23

HxC

B-1

56

HxC

B-1

57

HxC

B-1

67

HpC

B-1

89

TeC

B-77

GCxGC-IDTOFMSGC-IDHRMSGC-IDQISTMS/MS

0

2

4

6

8

10

12

14

16

TeC

B-81

PeC

B-1

26

HxC

B-1

69

RSD GCxGC-TOFMS: 2-17% (33%)RSD GC-HRMS: 4-8% (34%)RSD GC-MSMS: 6-22%

Page 76: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

PCDD/Fs in Fish

N = 6

15g sample size RSD GCxGC-TOFMS: 12-60% (95%)RSD GC-HRMS: 4-32% (64%)RSD GC-MSMS: 5-30% (44%)

0

0.5

1

1.5

2

2.5

3

3.5

4

2,3,7,

8-TeC

DD

1,2,3,

7,8-P

eCDD

1,2,3,

4,7,8-

HxCDD

1,2,3,

6,7,8-

HxCDD

1,2,3,

7,8,9-

HxCDD

1,2,3,

4,6,7,

8-HpC

DDOCDD

2,3,7,

8-TeC

DF

1,2,3,

7,8-P

eCDF

2,3,4,

7,8-P

eCDF

1,2,3,

4,7,8-

HxCDF

1,2,3,

6,7,8-

HxCDF

1,2,3,

7,8,9-

HxCDF

2,3,4,

6,7,8-

HxCDF

1,2,3,

4,6,7,

8-HpC

DF

1,2,3,

4,7,8,

9-HpC

DFOCDF

pg/g

fwGCxGC-IDTOFMSGC-IDHRMSGC-IDQISTMS/MS

Page 77: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

0

1000

2000

3000

4000

5000

1547 1549 1551 1553 1555 1557 1559

Cou

nts

0

50

100

150

200

1547 1549 1551 1553 1555 1557 1559

Cou

nts

Labels(~85pg)

Natives(~1pg)

1tR

PM = 4s RIC

1,2,3,7,8-PeCDF

Page 78: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

29002400190014009000

1

2

3

1tR (s)

2tR (s)

‘Cleaned’ Milk Extract

Analytes of interest

Matrix interferences

Page 79: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Non- and Mono-ortho PCBs in Milk

N = 6

RSD GCxGC-TOFMS: 5-20% (46%)RSD GC-HRMS: 2-10%RSD GC-MSMS: 7-15%

120g sample size

0

20

40

60

80

100

120P

eCB-

118

pg/g

fw

0

5

10

15

20

25

30

35

PeC

B-1

05

PeC

B-1

14

PeC

B-1

23

HxC

B-1

56

HxC

B-1

57

HxC

B-1

67

HpC

B-1

89

TeC

B-7

7

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

TeC

B-8

1

PeC

B-12

6

HxC

B-16

9

GCxGC-IDTOFMSGC-IDHRMSGC-IDQISTMS/MS

0

20

40

60

80

100

120P

eCB-

118

pg/g

fw

0

5

10

15

20

25

30

35

PeC

B-10

5

PeC

B-11

4

PeC

B-12

3

HxC

B-15

6

HxC

B-15

7

HxC

B-16

7

HpC

B-18

9

TeC

B-7

7

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

TeC

B-8

1

PeC

B-12

6

HxC

B-16

9

0

20

40

60

80

100

120P

eCB-

118

pg/g

fw

0

5

10

15

20

25

30

35

PeC

B-10

5

PeC

B-11

4

PeC

B-12

3

HxC

B-15

6

HxC

B-15

7

HxC

B-16

7

HpC

B-18

9

TeC

B-7

7

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

TeC

B-8

1

PeC

B-12

6

HxC

B-16

9

GCxGC-IDTOFMSGC-IDHRMSGC-IDQISTMS/MS

Page 80: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

PCDD/Fs in Milk

RSD GCxGC-TOFMS: 9-55% (75%)RSD GC-HRMS: 7-14% (34%)RSD GC-MSMS: 5-30%

N = 6

120g sample size

0

0.05

0.1

0.15

0.2

0.25

2,3,7,

8-TeC

DD

1,2,3,

7,8-P

eCDD

1,2,3,

4,7,8-

HxCDD

1,2,3,

6,7,8-

HxCDD

1,2,3,

7,8,9-

HxCDD

1,2,3,

4,6,7,

8-HpC

DDOCDD

2,3,7,

8-TeC

DF

1,2,3,

7,8-P

eCDF

2,3,4,

7,8-P

eCDF

1,2,3,

4,7,8-

HxCDF

1,2,3,

6,7,8-

HxCDF

1,2,3,

7,8,9-

HxCDF

2,3,4,

6,7,8-

HxCDF

1,2,3,

4,6,7,

8-HpC

DF

1,2,3,

4,7,8,

9-HpC

DFOCDF

pg/g

fwGCxGC-IDTOFMSGC-IDHRMSGC-IDQISTMS/MS

0.87±0.18

0.85±0.05

0.95±0.05

Page 81: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Mono-ortho PCBs in Pork

RSD GCxGC-TOFMS: 4-22%RSD GC-HRMS: 3-17%RSD GC-MS/MS: 9-18%

30g sample size

N = 6

0

20

40

60

80

100

PeCB-11

8PeC

B-105

PeCB-11

4PeC

B-123

HxCB-15

6HxC

B-157

HxCB-16

7HpC

B-189

pg/g

fw

GCxGC-TOFMSGC-HRMSGC-MS/MS

241.3 ± 28.3297.9 ± 8.09

268.8 ± 25.6

Page 82: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

PCDD/Fs in Pork

30g sample size

0

0.2

0.4

0.6

0.8

1

1.2

2,3,7,8-TeCDD

1,2,3,7,8-PeCDD

1,2,3,4,7,8-HxCDD

1,2,3,6,7,8-HxCDD

1,2,3,7,8,9-HxCDD

1,2,3,4,6,7,8-HpCDDOCDD

2,3,7,8-TeCDF

1,2,3,7,8-PeCDF

2,3,4,7,8-PeCDF

1,2,3,4,7,8-HxCDF

1,2,3,6,7,8-HxCDF

1,2,3,7,8,9-HxCDF

2,3,4,6,7,8-HxCDF

1,2,3,4,6,7,8-HpCDF

1,2,3,4,7,8,9-HpCDFOCDF

pg/g

fw

GCxGC-TOFMSGC-HRMSGC-MS/MS

RSD GCxGC-TOFMS: 15-71%RSD GC-HRMS: 4-16%RSD GC-MS/MS: 8-35%

N = 6

Page 83: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Comparison in terms of TEQs

Use of physico-chemical congener-specific dataand WHO-1998 TEFs to estimate the sum ofPCDD/F and PCB TEQs.

Parallel measurement of sample toxicities usingthe DR-CALUX assay on sub-samples.

Page 84: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

0

0.05

0.1

0.15

0.2

0.25

0.3

0.35

0.4

0.45

0.5

0.55

Pork Milk

pg/g

fw

0

0.05

0.1

0.15

0.2

0.25

0.3

0.35

0.4

0.45

0.5

0.55

Pork Milk

pg/g

fw

0

0.5

1

1.5

2

2.5

3

3.5

4

4.5

Fish

pg/g

fw

0

0.5

1

1.5

2

2.5

3

3.5

4

4.5

Fish

pg/g

fwGCxGC-IDTOFMS GC-IDHRMS GC-IDQISTMS/MS DR-CALUX

0

0.05

0.1

0.15

0.2

0.25

0.3

0.35

0.4

0.45

0.5

0.55

Pork Milk

pg/g

fw

0

0.05

0.1

0.15

0.2

0.25

0.3

0.35

0.4

0.45

0.5

0.55

Pork Milk

pg/g

fw

0

0.5

1

1.5

2

2.5

3

3.5

4

4.5

Fish

pg/g

fw

0

0.5

1

1.5

2

2.5

3

3.5

4

4.5

Fish

pg/g

fwGCxGC-IDTOFMS GC-IDHRMS GC-IDQISTMS/MS DR-CALUX GCxGC-IDTOFMS GC-IDHRMS GC-IDQISTMS/MS DR-CALUX

Bottom: PCDD/F TEQTop: PCB TEQ

Page 85: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Comparison in terms of CostBased on 1,000 samples/year over 5 years(including employment, purchases, paying-off,maintenance, licensing, etc…)

GC-IDHRM

S

GCxGC-ID

TOFMS

GC-IDQIS

TMS/M

S

DR-CALUX

Scientist employment 23% 35% 35% 36%Extraction 11% 8% 11% 7%Clean-up 28% 27% 33% 29%Measurement 38% 30% 21% 8%Licensing and royalties - - - 20%

Cost per sample (Euros) 500 500 420 270

Page 86: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

GCxGC-TOFMS using ID works fine.

QA/QC criteria of ‘reference method’ can beapplied PLUS 2 tR available for specificity.

TOFMS is a robust instrument.

Integration of peaks requires more work.

A sensitivity improvement is still welcome.

MS-based alternative methods not to beassimilated to biological screening methods.

Take Home Message #1

Page 87: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Speed(Low cost)

Selectivity

Sensitivity

Political, economical, …

Real life Pyramid

GC-QISTLRMS²

GC-TOFMS

GCxGC-TOFMS

EIAs, RBAs

GC-HRMS

Trend

Take Home Message #2

Page 88: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

1.85

2.05

2.25

2.45

2.65

2.85

3.05

700 1200 1700 2200 2700

1tR (s)

2tR (s)

1

2 3

4

5

6

7

8

10

9

11 12

13

14

1516

17

18

19

20

21

24

22

23

25

2627

28

29

30

31

32

3334

35

36

37

35 analyte/45min0.8 analyte/minOne single injection

Multi-Group Analyte Measurement

GCxGC-IDTOFMS

Page 89: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Source tracking (pattern recognition)

Page 90: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

144x4 158x10 172x18 TICx-0.5

Metabolite Screening

GCxGC-LRTOFMS

Focant, Sjödin, Patterson Jr., unpublished data.

Page 91: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Sensitivity Backup GCxGC-IDHRMS

Sectors

Selective MSLow data densityTarget analytes

R>10,000

Page 92: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

GCxGC-HR(sector)MSCryogenic zone compression on sector HRMS

- Attogram (10-18g)detection level…

- Not much ions inthe MS anymore…

313ag 2,3,7,8-TCDD(S/N=890)

Quantity Number of moles Number of molecules

1 microgram (µg) or 10-6 g 3 nanomoles or 3.10-9 2,000,000,000,000,000 (2.1015)1 nanogram (ng) or 10-9 g 3 picomoles or 3.10-12 2,000,000,000,000 (2.1012)1 picogram (pg) or 10-12 g 3 femtomoles or 3.10-15 2,000,000,000 (2.109)1 femtogram (fg) or 10-15 g 3 attomoles or 3.10-18 2,000,000 (2.106)1 attogram (ag) or 10-18 g 3 zeptomoles or 3.10-21 2,000 (2.103)1 zeptogram (zg) or 10-21 g 3 yaktomoles or 3.10-24 2 (2.100)

1 yaktogram (yg) or 10-24 g Phantom moles 0

Quantity Number of moles Number of molecules

1 microgram (µg) or 10-6 g 3 nanomoles or 3.10-9 2,000,000,000,000,000 (2.1015)1 nanogram (ng) or 10-9 g 3 picomoles or 3.10-12 2,000,000,000,000 (2.1012)1 picogram (pg) or 10-12 g 3 femtomoles or 3.10-15 2,000,000,000 (2.109)1 femtogram (fg) or 10-15 g 3 attomoles or 3.10-18 2,000,000 (2.106)1 attogram (ag) or 10-18 g 3 zeptomoles or 3.10-21 2,000 (2.103)1 zeptogram (zg) or 10-21 g 3 yaktomoles or 3.10-24 2 (2.100)

1 yaktogram (yg) or 10-24 g Phantom moles 0

Patterson Jr., Welch , Turner , Focant, Organohalogen Compds 67 (2005) 107.

Page 93: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Report with undesirable ‘not detected’Report with NO ‘not detected’

Sensitivity not a Dimension…Low level sample

Sample preparation

GCxGC-IDHRMS(Selected Descriptors)

GC-IDHRMS(Multi-Group)

2,3,7,8-TCDD… 17 PCDD/Fs + NO-PCBs

Page 94: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

- D. Patterson Jr., W. Turner, A. Sjödinand Lab. staff at CDC

- G. Eppe, C. Pirard, M.-L. Scippo andLab. staff in Liège

- Fluid Management Systems Inc.- Leco Corp.

Thanks to

Page 95: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Related papers (i)• J.-F. Focant, A. Sjödin, D.G. Patterson Jr., 2006. Human Biomonitoringof Persistent Toxicants using Comprehensive Two-Dimensional Gas Chromatography and Time-of-Flight Mass Spectrometry. In: W.M.A.Niessen (Eds.). The Encyclopedia of Mass Spectrometry, Volume 8, Hyphenated Methods. ElsevierAmsterdam, The Netherlands, pp. 553-564.

• G. Eppe, E. De Pauw, J.-F. Focant, 2006. High-Resolution GC Coupled to High-Resolution MS in the Analysis of Dioxins and Related Substances, Principles and Applications. In: W.M.A. Niessen (Eds.). The Encyclopedia of Mass Spectrometry, Volume 8, Hyphenated Methods. ElsevierAmsterdam, The Netherlands, pp. 531-541.

•J.-F. Focant, G. Eppe, M.-L. Scippo, A.-C. Massart, C. Pirard, G. Maghuin-Rogister, E. De Pauw, Comprehensive two-dimensional gas chromatography isotope dilution time-of-flight mass spectrometry for the measurement of dioxins and PCBs in foodstuffs: comparison against other methods, J. Chromatogr. A. 1086 (2005) 45-60. .

Page 96: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Related papers (ii)• J.-F. Focant, C. Pirard, G. Eppe, E. De Pauw, Recent advances in mass spectrometric measurement of dioxins, J. Chromatogr. A. 1067 (2005) 265-275.

• J.-F. Focant, A. Sjödin, W.E. Turner, D.G. Patterson Jr., Measurement of Selected Polybrominated Diphenyl ethers, Polybrominated and Polychlorinated Biphenyls, and Organochlorine Pesticides in Human Serum and Milk using Comprehensive Two-Dimensional Gas Chromatography Isotope Dilution Time-of-Flight Mass Spectrometry, Anal. Chem. 76 (2004) 6313-6320.

• G. Eppe, J.-F. Focant, C. Pirard, E. De Pauw, PTV-LV-GC/MS/MS as screening and complementary method to HRMS for the monitoring ofdioxin levels in food and feed, Talanta 63 (2004) 1135-1146.

• J.-F. Focant, C. Pirard, E. De Pauw, Automated sample preparation-fractionation for the measurement of dioxins and related compounds in biological matrices: A review. Talanta 63 (2004) 1161-1113.

Page 97: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Related papers (iii)• J.-F. Focant, E. Reiner, K. MacPherson, J. Cochran, F. Dorman, A. Sjödin, D.G. Patterson Jr., Measurement of PCDDs, PCDFs, and non-ortho-PCBs by Comprehensive Multi-Dimensional Gas Chromatography-Isotope Dilution Time-of-Flight Mass Spectrometry (GCxGC-IDTOFMS), Talanta 63 (2004) 1231-1240.

• J.-F. Focant, A. Sjödin, D.G. Patterson Jr., Improved Separation of the 209 Polychlorinated Biphenyl Congeners Using Comprehensive Two-Dimensional Gas Chromatography-Time-of-Flight Mass Spectrometry, J. Chromatogr. A. 1040 (2004) 227-238.

• J.-F. Focant, J.W. Cochran, J.-M.D. Dimandja, E. De Pauw, A. Sjödin, W.E. Turner, D.G. Patterson Jr., High throughput analysis of selected polychlorinated biphenyls (PCBs) in human serum by gas chromatography/isotope dilution time-of-flight mass spectrometry (GC/IDTOFMS), Analyst 129 (2004) 331-336.

Page 98: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

Related papers (iv)•J.-F. Focant, A. Sjödin, D.G. Patterson Jr., Qualitative evaluation of thermal desorption-programmable temperature vaporization-comprehensive multi-dimensional gas chromatography-time-of-flight mass spectrometry for the analysis of selected halogenated contaminants. J. Chromatogr. A 1019 (2003) 143-156.

• C. Pirard, E. De Pauw, J.-F. Focant, A new strategy for comprehensive analysis of polybromodiphenylethers (PBDEs), polychlorodibenzo-p-dioxins (PCDDs), polychlorodibenzofurans (PCDFs) and polychlorobiphenyls (PCBs) by gas chromatography coupled with mass spectrometry (GC/MS). J. Chromatogr. A 998 (2003) 169-181.

• J.-F. Focant, E. De Pauw, Fast automated extraction and clean-up of biological fluids for polychlorinated dibenzo-p-dioxins, dibenzofuransand coplanar polychlorinated biphenyls analysis. J. Chromatogr. B 776 (2002) 199-212.

Page 99: Emerging Hyphenated and Comprehensive Multi-Dimensional … · 2020. 6. 13. · 23478-PeCDF PCDD/F Calibration Standard Area Certified Calculated Response Expected Calculated Ion

• J.-F. Focant, H. Shirkhan, E. De Pauw, On-line automated pPLE andmulti-column clean-up system for PCDD/F and PCB analysis in foodstuffs. Organohalogen Compds 55 (2002) 33-36.

• C. Pirard, J.-F. Focant, E. De Pauw, An improved clean-up strategy for simultaneous analysis of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and polychlorinated biphenyls (PCBs) in fatty food samples. Anal. Bioanal. Chem. 372 (2002) 373-381.

•J.-F. Focant, C. Pirard, G. Eppe, E. De Pauw, Fast Clean-up for polychlorinated dibenzo-p-dioxins, dibenzofurans and coplanar polychlorinated biphenyls analysis of high fat content biological samples. J. Chromatogr. A 925 (2001) 207-221.

• J.-F. Focant, G. Eppe and E. De Pauw, Optimisation and Use of Tandem Mass Spectrometry in Comparison with Immunoassay and HRGC/HRMS for PCDD/Fs Screening, Chemosphere 43 (2001) 417-424.

Related papers (v)