emission inventory analysis website docs/class 3/emission...o1700 valid sics available osic 7011 =...
TRANSCRIPT
![Page 1: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/1.jpg)
1
Emission Inventory
Stephen K. ShawAir Quality AnalysisOctober 20, 2006
![Page 2: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/2.jpg)
2
The Basics
![Page 3: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/3.jpg)
3
Criteria Pollutants
TOG: Total Organic GasesROG: Reactive Organic Gases (used by ARB)
VOC: Volatile Organic Gases (used by EPA and SJV)
CO: Carbon MonoxideNOX: Oxides of NitrogenSOX: Oxides of SulfurPM: Particulate MatterPM10: Particulate Matter < 10 MicronsPM2.5: Particulate Matter < 2.5 Microns
__
![Page 4: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/4.jpg)
4
Types of Sources
StationaryArea-WideMobileNon-Anthropogenic
![Page 5: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/5.jpg)
5
Stationary Sources
Point Aggregated Point
Gas ‘Em Fast
![Page 6: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/6.jpg)
6
Area-Wide
ROG
![Page 7: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/7.jpg)
7
Mobile
On-Road
Non-Road
![Page 8: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/8.jpg)
8
Non-Anthropogenic
![Page 9: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/9.jpg)
9
How Do We Identify and Categorize Sources?
Point Sources– Combination of SCC and SIC Codes– Each SCC/SIC Combination is Mapped to
an EICArea Sources– Each category is assigned a unique EIC
![Page 10: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/10.jpg)
10
Emission Inventory Code (EIC)
14 Digit Code that Categorize Emission SourcesCreated and Maintained by ARBEach Valid SCC/SIC is Mapped to an EICEICs can have many SCC/SIC assignedEach Area Source Category Identified by EIC
![Page 11: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/11.jpg)
11
Use of EICs
Categorize and Report EmissionsIdentify Each Area Source CategoryProvides Automatic Reconciliation of Point and Area Sources
![Page 12: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/12.jpg)
12
Example of an EIC
040-005-0110-0000
– 040 Fuel Combustion Petroleum Refining
– 005 Boiler (Source Category) – 0110 Natural Gas (Material Type)– 0000 Sub-category (Sub-category User
Defined)
![Page 13: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/13.jpg)
13
Source Classification Code (SCC)
8 Digit Code to Identify Emission ProcessesCreated by U.S. EPA9865 Valid SCCs AvailableLarge NG Boiler = 1-03-006-03
![Page 14: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/14.jpg)
14
Standard Industrial Classification (SIC)
4 Digit Code to Identify Business ActivityPublished by U.S. OMB1700 valid SICs AvailableSIC 7011 = Hotel and MotelsSIC 2911 = Petroleum Refining
![Page 15: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/15.jpg)
15
SICs are used in two placesFacility SIC Identifies Primary Activity of Entire FacilityProcess SIC Identifies Type of Activity for a Specific ProcessExample of Facility vs. Process SIC:
• Wood Furniture Manufacturer 2511 with a Metal Parts Coating Operation 2514
Facility vs. Process SIC
![Page 16: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/16.jpg)
16
How Do We Estimate Emissions?
![Page 17: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/17.jpg)
17
Emission Calculation
Number ofUnits
Emissionsper Unit
x = TotalEmissions
Process Rate(Activity) Emission Factor
![Page 18: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/18.jpg)
18
Calculations Methods
Bottom-up (Typically Point Sources)– Number of Units * Emission Factor– Gallons of paint used in the facility– Point Source Method
Top-down (Typically Area Sources)– Number of Units Sold * Emission Factor– Gallons of paint sold in the County– Area Source Method
![Page 19: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/19.jpg)
19
Which Method Do I Use?
Point Source Methods
Area Source Methods
Point Sources
Aggregated Point
Area-Wide
Mobile
Non-Anthropogenic Sources
![Page 20: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/20.jpg)
20
Mobile EmissionsEMFAC 2002 Model Moving to EMFAC 2007 soonMost Off-Road categories are calculated with the Off-Road emissions model
![Page 21: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/21.jpg)
21
ResponsibilitiesLocal Districts– Develop Local Point Source Inventory– Estimate Emissions for 1/3 of Area Source
CategoriesARB– Estimate Mobile Source Emissions– Estimate Emissions for 2/3 of Area Source
Categories– Develop and Report Statewide Inventory
![Page 22: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/22.jpg)
22
Types of Inventories
Annual AveragePlanning– Summer Planning– Winter Planning
ForecastedGridded / Modeling
![Page 23: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/23.jpg)
23
Important Points
EI is a ‘live’ databaseConstantly changing (improved)Only Snapshots of the EI are usedSnapshots may or may not be improvedCan only compare EIs of the same snapshot and publishing date
![Page 24: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/24.jpg)
24
Annual Average Inventories
![Page 25: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/25.jpg)
25
What is a Average Annual Inventory ?– Annual Emissions divided by 365– Most commonly seen– All criteria pollutants– Not detailed enough for technical use– Example: Fireplaces
Average Annual EI
![Page 26: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/26.jpg)
26
Planning Inventories
![Page 27: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/27.jpg)
27
What is a Planning Inventory ?– Planning Inventories are a refinement
of annual emission inventories– Created only for non-attainment areas– Ozone or precursors (i.e. ROG and
NOx), CO, SOx, and PM10 are the non-attainment pollutants considered at this time
Planning EI’s
![Page 28: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/28.jpg)
28
Purpose of Planning Inventories– To characterize emissions of a non-
attainment pollutant (or its precursors) during air quality exceedance periods
– A tool for air quality planners to assess what sources to target for emission reductions as required under the federal CAA
Planning EIs (continued)
![Page 29: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/29.jpg)
29
Periods Analyzed – Ozone: summer operating period May-Oct (mainly concerned with ROG and NOx)– CO: winter operating period Nov-Apr– Other Periods: For the San Joaquin PM10
SIP, quarterly inventories were developed
Planning EIs (continued)
![Page 30: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/30.jpg)
30
Calculation Method
SEMS (t/d) = EMS (t/y) * TF Where: SEMS = Seasonal emissions (tons/seasonal day) EMS = Annual Emissions (tons/year) TF (Temporal Factor) = SEAS_FRAC / 182.5
SEAS_FRAC = (i) Sum of fractional monthly throughputs Summer: May-October Winter: November-April
or (ii) The ratio of the operating days in the season to the operating days in
the year (intermittent sources)
![Page 31: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/31.jpg)
31
Planning Inventories (cont.)Temporal Distribustion of Ag-burn Prunnings Emissions for
Stanislaus County
05
10152025
Jan
Feb
Mar Arp
May Ju
n
Jul
Aug Se
p
Oct
Nov
Dec
Perc
ent
Summer (30.0) Winter (70.1)
![Page 32: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/32.jpg)
32
Forecasted EmissionInventories
![Page 33: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/33.jpg)
33
IntroductionUsed to predict future emission levels based on expectations of future economic conditions, population growth, and emission controlsUsed to develop baseline emission inventory projections for SIP and local AQMPs
![Page 34: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/34.jpg)
34
Introduction (continued)
Also used to backcast emissions (for historical years) to account for improved inventory methodologies Air basin and county level emission trends calculated for period 1975-2030
![Page 35: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/35.jpg)
35
Socioeconomic and Demographic Growth Activity
![Page 36: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/36.jpg)
36
Growth FactorsWhat are growth factors?– Derived from county-specific economic
activity profiles, population forecasts, and other socio/demographic activity
![Page 37: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/37.jpg)
37
Growth Factors (Continued)
Sources of data– District supplied data based on
information from COGs– Economic activity studies contracted
by ARB (e.g. DRI/McGraw-Hill, CSU Fullerton, Pechan and Assoc.)
– Demographic data (e.g. population estimates-DOF, VMT-Caltrans)
![Page 38: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/38.jpg)
38
Growth Factors (Continued)
How are growth factors linked to emissions?
– “Rule of Thumb”: Growth profiles are typically associated with the type of industry and secondarily to the type of emission process.
• Point Sources: Economic output profiles by industrial sector are linked to emission sources via SIC.
![Page 39: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/39.jpg)
39
Growth Factors (Continued)
• Area-wide and Aggregated Point Sources: Other growth surrogates such as population, dwelling-units, fuel usage etc. may be used
Example: Emissions from residential fuel combustion are generally linked to # of dwelling-units as a growth parameter
![Page 40: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/40.jpg)
40
Control Factors
![Page 41: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/41.jpg)
41
Control FactorsWhat are control factors?– Control factors are derived from
adopted ARB regulations or district rules which impose emission reductions or a technological change on a particular emission process
![Page 42: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/42.jpg)
42
Control Factors (Continued)
Sources of data– ARB Regulations: Control profiles are derived from adopted
state regulations by ARB staff (e.g. consumer products, clean fuels, etc.)
– District Rules: Control profiles are developed by district
staff based on adopted district rules (e.g. IC engine rules)
– Other regulatory agencies: DPR, U.S. EPA, etc.
![Page 43: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/43.jpg)
43
Control Factors (Continued)
How are control factors linked to emissions?– “Rule of Thumb”: Control data are closely
linked to the type of emission process and secondarily to the type of industry
– Control data are assigned to emission categories which are targeted by the rules
![Page 44: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/44.jpg)
44
E (s,p)=E (s,p) * TF * GF * [CF(m ,s,p) * CF(m ,s,p) *...* CF(m ,s,p)]
where:
E = Emissions in the future yearE = Emissions in the base year
where:Eby = Process Rate * Emission Factor
TF = Temporal FactorGF = Growth Factor (Growth Level FY / Growth Level BY)CF = Control Factor (Control Level FY / Control Level BY)s = The source category (SCC/SIC or EIC)p = The pollutantm = The control measure impacting the source categoryj = The number of measures impacting the source category, s
fy by 1 2 j
fy
by
General Forecasting Equation
![Page 45: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/45.jpg)
45
Modeling Inventories
![Page 46: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/46.jpg)
46
Modeling Inventories
Day SpecificHourly SpecificLocation SpecificGriddedEach EIC/SCC/SIC is speciated into component chemicals
![Page 47: Emission Inventory Analysis Website Docs/Class 3/Emission...O1700 valid SICs Available OSIC 7011 = Hotel and Motels OSIC 2911 = Petroleum Refining. 15 OSICs are used in two places](https://reader030.vdocuments.net/reader030/viewer/2022040403/5e85efeb9993ea379a3b3148/html5/thumbnails/47.jpg)
47
Emission Inventory Resources
California Air Resources Board(http://www.arb.ca.gov)EPA (http://www.epa.gov/ttn/chief/net/neidata.html)