€¦ · en iso 13795 tdl values (test result) resistance ... bursting strength dry en iso 13938-1...

15
www.ademhavvamed.com

Upload: others

Post on 29-Mar-2021

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: €¦ · EN ISO 13795 TDL Values (Test Result) Resistance ... Bursting Strength Dry EN ISO 13938-1 kPa H40 118 Bursting Strength Wet EN ISO 13938-1 kPa H40 110 Tensile Strength -

www.ademhavvamed.com

Page 2: €¦ · EN ISO 13795 TDL Values (Test Result) Resistance ... Bursting Strength Dry EN ISO 13938-1 kPa H40 118 Bursting Strength Wet EN ISO 13938-1 kPa H40 110 Tensile Strength -

Adem & Havva Sağlık Grubu

Adem & Havva Sağlık Grubu olarak,

! Sa Clinic)

! Sa irketi ( stanbul Health Travel)

!

!

Page 3: €¦ · EN ISO 13795 TDL Values (Test Result) Resistance ... Bursting Strength Dry EN ISO 13938-1 kPa H40 118 Bursting Strength Wet EN ISO 13938-1 kPa H40 110 Tensile Strength -

Adem & Havva Med�kal

Adem & Havva Medikal olarak,

! Koruyucu Tulum

! Koruyucu Siperlik

! Koruyucu Maske

!

Page 4: €¦ · EN ISO 13795 TDL Values (Test Result) Resistance ... Bursting Strength Dry EN ISO 13938-1 kPa H40 118 Bursting Strength Wet EN ISO 13938-1 kPa H40 110 Tensile Strength -

Sertifikalarımız

Page 5: €¦ · EN ISO 13795 TDL Values (Test Result) Resistance ... Bursting Strength Dry EN ISO 13938-1 kPa H40 118 Bursting Strength Wet EN ISO 13938-1 kPa H40 110 Tensile Strength -

Sertifikalarımız

Page 6: €¦ · EN ISO 13795 TDL Values (Test Result) Resistance ... Bursting Strength Dry EN ISO 13938-1 kPa H40 118 Bursting Strength Wet EN ISO 13938-1 kPa H40 110 Tensile Strength -

Sert�f�kalarımız

Page 7: €¦ · EN ISO 13795 TDL Values (Test Result) Resistance ... Bursting Strength Dry EN ISO 13938-1 kPa H40 118 Bursting Strength Wet EN ISO 13938-1 kPa H40 110 Tensile Strength -

Sert�f�kalarımız

Page 8: €¦ · EN ISO 13795 TDL Values (Test Result) Resistance ... Bursting Strength Dry EN ISO 13938-1 kPa H40 118 Bursting Strength Wet EN ISO 13938-1 kPa H40 110 Tensile Strength -

Sert�f�kalarımız

Page 9: €¦ · EN ISO 13795 TDL Values (Test Result) Resistance ... Bursting Strength Dry EN ISO 13938-1 kPa H40 118 Bursting Strength Wet EN ISO 13938-1 kPa H40 110 Tensile Strength -

Koruyucu TulumKumaş Özellikleri :

Koruyucu Tulum kumaşı, PP (%100 Polypropylene)Spunbond Nonwoven Kumaş lamine edilerek elde edilmektedir.

Spunbond Nonwoven ürünleri isteğe göre yanmayı geciktirici olarak üretebilmektedir. Yanmayı geciktirme DIN 4102, FMVSS 302, ISO 4589-1, EN 13984, EN 13859 ve en önemlisi FR = Fire retardant , EN 13501-1 yangın sınıfı B2 olarak üretilmektedir.

Kumaşın gramı ; 55 - 60 g/m2 arası değişmektedir.

L – XL ve XXL olmak üzere üretilmekte olup siparişe göre diğer bedenlerde de üretmekteyiz.

Page 10: €¦ · EN ISO 13795 TDL Values (Test Result) Resistance ... Bursting Strength Dry EN ISO 13938-1 kPa H40 118 Bursting Strength Wet EN ISO 13938-1 kPa H40 110 Tensile Strength -

Koruyucu Tulum / Kumaş Özellikleri

PHYSICAL AND TECHNICAL SPECIFICATIONS

PRODUCT : Hotmelt Laminate Document Rev. Of 11 February 2020

Total Grammage :60 gsm

Nonwoven Weight : 33 gsm

Pe / Cast Weight : 25 gsm

Hotmelt Weight : 2 gsm

Composition: Carded thermobonded polyester based

Product Code : THP 201-60 (2 Layers)

Film: Antistatic Multilayer cast embossed polyoefine

based

Weight Tolerance : +/- 2

Widht Tolerance : +/- 5

Type Of Lamination: Hotmelt

Color : White Color Ref. : 002

Physical Properties Test Method Unit EN ISO 13795 TDL Values (Test Result)

Resistance To Liquid Penetration EN ISO 20811

Cm/H₂O 100 214,6

Bursting Strength Dry EN ISO 13938-1 kPa 40 118

Bursting Strength Wet EN ISO 13938-1 kPa 40 110

Tensile Strength - Dry EN ISO 29073-3 N 20 MD:48.05

CD: 42,12

Resistance To Microbial Penetration-Dry

EN ISO 22612 CFU ≤300 14

Resistance To Microbial Penetration-Wet

EN ISO 22610 BI 6,0 6,0

Cleanliness-Particular matter EN ISO 9073-10 IPM ≤3,5 3,3

Linting EN ISO 9073-10 Log(10) ≤4,0 3,4

Cytotoxicity Non-cytotoxic as per ISO 10993-5:2009 tests for in vitro

cytotoxicity.

Skin Sensitivisation Non-sensitizer as per ISO 10993-10 tests for skin sensitization.

Skin Irritating Non-irritant as per ISO 10993-10 tests for irritation.

*Due to the nature of polyolefins, recrystallization occurs which may change the physical values.

*The above figures are an estimate of expected mean values measured after EO sterilization.

*The tests have been performed according to EN ISO standarts.

*These figures must only be used as guideline as they are an estimate.

Issued by Broche Nonwovens Technical Manager

Tansu Mocuk

Page 11: €¦ · EN ISO 13795 TDL Values (Test Result) Resistance ... Bursting Strength Dry EN ISO 13938-1 kPa H40 118 Bursting Strength Wet EN ISO 13938-1 kPa H40 110 Tensile Strength -

Koruyucu Tulum Ürün Görselleri

Page 12: €¦ · EN ISO 13795 TDL Values (Test Result) Resistance ... Bursting Strength Dry EN ISO 13938-1 kPa H40 118 Bursting Strength Wet EN ISO 13938-1 kPa H40 110 Tensile Strength -

Koruyucu Siperlik

Page 13: €¦ · EN ISO 13795 TDL Values (Test Result) Resistance ... Bursting Strength Dry EN ISO 13938-1 kPa H40 118 Bursting Strength Wet EN ISO 13938-1 kPa H40 110 Tensile Strength -

Koruyucu Maske

FFP2 ve FFP3 Maskeler

• Ventilli

• Ventilsiz

3 Katlı Cerrahi Maske

• Full Ultrasonic

• Yarı Ultrasonic

• Telli , Telsiz

Page 14: €¦ · EN ISO 13795 TDL Values (Test Result) Resistance ... Bursting Strength Dry EN ISO 13938-1 kPa H40 118 Bursting Strength Wet EN ISO 13938-1 kPa H40 110 Tensile Strength -

Tek Kullanımlık Önlük

Page 15: €¦ · EN ISO 13795 TDL Values (Test Result) Resistance ... Bursting Strength Dry EN ISO 13938-1 kPa H40 118 Bursting Strength Wet EN ISO 13938-1 kPa H40 110 Tensile Strength -

www.ademhavvamed.com

Cumhuriyet Mah. İncirlidede Cad. No:6-2 Anthill, Şişli – İSTANBUL – TÜRKİYE

T : +90 212 397 15 97 M : +90 543 546 10 00 [email protected]