4
One Integrated Approach to Healthcare. Endoscopy Solutions SYSTEM 1 ® endo Liquid Chemical Sterilant Processing System Commit to a HIGHER STANDARD OF Care

Upload: others

Post on 31-Jan-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

  • Endoscopy SolutionsEndoscopy Solutions

    One Integrated Approach to Healthcare.

    Endoscopy Solutions

    SYSTEM 1® endo Liquid Chemical Sterilant Processing System

    Commit to a HIGHER STANDARD OF

    Care

  • Assuring patients that best practice reprocessing solutions are being used is critical in today’s fast-paced Endoscopy departments.

    Patient Safety is Never Semi-Critical

    MaxFlow Adapters provide complete sterilant use-dilution flow to all lumens and device ports.

    The processor delivers

    S40® Sterilant Concentrate

    use dilution to all parts of the

    endoscope, including surfaces

    and ports. These areas might be

    shielded from germicide contact in

    AERs with tight fitting adapters.

    Requires no special ventilation and use-dilution can rinse safely down the drain

    The validated process of SYSTEM 1 endo Liquid Chemical Sterilant Processing System goes beyond

    high-level disinfection. The process eliminates all microbial life, including bacterial spores,

    providing assurance that the risk of microbial transmission is lower compared to HLD.

    A Higher Standard of Reprocessing

    Microorganism Type Sterilization

    Disinfection

    High Level

    Intermediate Level

    Low Level

    More Difficultto Kill

    Bacterial Spores

    Mycobacteria

    Non-enveloped viruses

    Fungi

    Gram Negative Bacteria

    Gram Positive Bacteria

    Enveloped Viruses

    In line with the time honored Spaulding classification scheme, sterilization is recommended for all semi-critical devices.

    Less Difficultto Kill

  • Reprocess and Go

    A Higher Standard of Productivity

    Industry leading cycle time for the liquid chemical sterilization

    of cleaned, immersible, reusable semi-critical heat-sensitive medical

    devices and their accessories.

    18MIN

    Quick scan captures device and technician

    Be audit ready with historical digital data on demand

    No required aeration

    allows for immediate

    use or storage

    after liquid chemical

    sterilization.

    The control guides you through the process and provides seemless tracking. ConnectAssure* Technology

    stores and displays the results - ease of use and electronic record keeping at your fingertips.

  • STERIS Corporation5960 Heisley RoadMentor, OH 44060-1834 • USA440-354-2600 • 800-548-4873www.steris.comDocument # M9463EN.2019-05, Rev. B

    Printed 05/2019©2019 STERIS Corporation. All rights reserved. Printed in USA.

    For more information about the SYSTEM 1 endo Liquid Chemical Sterilant Processing System visit steris.com/system1endo

    The SYSTEM 1 endo Processor is part of our complete line of endoscopy solutions.

    *ConnectAssure Technology is a software package sold separately to support select STERIS solutions

    Validated DevicesValidated for material compatibility and efficacy when processing specific models of devices including, but not limited to, the following types:

    • Duodenoscopes• Colonoscopes

    • Gastroscopes • Bronchoscopes

    PRE-KLENZ™ Soak Shield

    Reliance™ Endoscope Transport System

    Acu-sInQ™ Complete

    Endoscope Cleaning Aid

    System

    Reliance™ Endoscope Drying and Storage Cabinet