Energy Management Diagnostics
ENERGY STAR Monthly Partner Web Conference
March 21, 2007Call-in Number: 1-866-299-3188Conference Code: 202 343 9965
![Page 2: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/2.jpg)
About The Web Conferences
• Monthly
• Topics are structured on a strategic approach to energy management
• Opportunity to share ideas with others
• Slides are a starting point for discussion
• Open & Interactive
• Supports the ENERGY STAR Challenge to build a better world, 10% at time
![Page 3: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/3.jpg)
Web Conference Tips
• Mute phone when listening! Improves soundquality for everyone.Use * 6 – to mute and # 6 to un-mute
• Hold & Music – If your phone system has music-on-hold, please don’t put the webconference on hold!
• Presentation slides will be sent by email to all participants following the web conference.
![Page 4: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/4.jpg)
Today’s Web Conference
Energy Management Diagnostics – Using metering information to identify and solveenergy use problems
Presenters:
• Carlos Montanez – Philips Academy
• Gary Smith – Honda of America
![Page 5: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/5.jpg)
Phillips Andover Academy Energy Star Web Conference
Carlos Montanez Jonathan McDonnell
3/21/07
(Photo by John Hurley)
![Page 6: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/6.jpg)
Background
Phillips Andover Academy is a private co-educational boarding school.
• Founded in 1778 • Grades 9-12 w/ post graduate year • International students from 36 countries
• Located just north of Boston • Tuition cost for Fall 2007 $38,000
![Page 7: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/7.jpg)
Phillips Academy Campus
500 Acres
Power Plant
N
![Page 8: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/8.jpg)
Facts
• 150+ Buildings w/ over 1.85 million ft2
• Annual Campus growth for the past five yrs = 4.6 % • 1012 students, approx. 800 Boarders • 258 faculty, 338 staff • Annual Elect. usage @ approx. 13.5 million KW • Annual Natural Gas usage @ approx. 90,000 mmBTU• Annual Diesel fuel usage @ approx. 420,000 gals. • Estimated energy costs for FY07 approx. $4.8 million
dollars
![Page 9: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/9.jpg)
What lead to the decision to install extensive sub-meters?
• Old Maxim “You can’t manage what you don’t measure”
• Education is a business, we must compete with other schools for students
• Rising costs in energy have made a huge impact in adequately funding facilities improvements
• As a Facilities Professional, it is my responsibility to effectively manage the risingcosts of energy at Phillips Academy
![Page 10: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/10.jpg)
What do you track and monitor? Explain how this information is used to
manage energy use.
• One of the biggest challenges was capturing energy usage throughout campus from thosebuildings that receive their heat and electricityfrom the Central Heating and Power Plant.
• The data can then be entered into a spreadsheet to establish a BTU/ft2 index for comparison purposes.
![Page 11: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/11.jpg)
What do you track and monitor?
We track and monitor: • Steam flow and condensate returns from the
Power Plant to all areas of the Campus. • Steam usage in every building served by the
Power Plant. • All of the Electricity that leaves the Power Plant
to the campus buildings • All the Electric usage in the buildings served by
the Power Plant.
![Page 12: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/12.jpg)
How is this information used to manage energy consumption?
We collect all of this information to trend building energy usage, campus distribution losses, and compare against historical averages to identify areas to improve upon.
![Page 13: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/13.jpg)
Energy Management System Connection
Condensate Meter
Water Meter
Condensate Sub-meters • 10 Dorms • 5 Administration Buildings • 14 Academic Buildings
![Page 14: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/14.jpg)
Digital Energy Meter Current Transformer(s)
Digital Energy Sub-meters • 14 Dorms • 5 Administration Buildings • 5 Academic Buildings • 2 Chiller Plants
![Page 15: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/15.jpg)
Diagnostic Story
What first alerted you that there was anissue/problem?
• In 1994 the Central Heating and Power Plant was exporting about 1 million lbs/stm/day to thecampus when the Outside Air temperature wasin the single digits.
• The amount of condensate return was approx. 55%. The school was losing 45% due to leaks indirect burial steam lines and within the buildings.
![Page 16: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/16.jpg)
What steps did you take to determine where the problem was coming from?
• Installed sub-meters on all steam lines leaving the Power Plant and condensate coming back from the campus.
• Monitored and tracked distribution percentage differences and conducted steam vault in-service audits
• Made Capital requests to the administration to invest in steam line improvements, building mechanical systemupgrades, and sub-metering installations
• Isolated piping sections from vault to vault to determine leak locations
![Page 17: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/17.jpg)
How did you fix it?
• We began by performing a comprehensive capital replacement program of areas identified with pipelinefailures.
• Received annual funding for steam line replacement. To date the school has invested over $9 million dollars in improvements and renewal.
• Today, the steam condensate losses are approx. 9%-11%
• In today’s dollars, these improvements would have saved over $7,800 in one day based upon our initialconditions in 1994.
![Page 18: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/18.jpg)
Power Plant Monthly Steam Usage
January 2007
![Page 19: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/19.jpg)
Power Plant Condensate Sub-meter
![Page 20: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/20.jpg)
Some Lessons
• Identify the low hanging fruit (Energy Hogs). They are the easiest pickings and then put a program together.
• Convince management that the investment into sub-metering is worth every penny. (Lighting retrofits,dehumidification, fume hoods, boiler burner technology,capacitor banks and co-generation)
• Document and demonstrate that savings in energy are being realized by collecting accurate data.
• Success breeds success, especially when the administration sees energy usage reductions andresultant savings being effectively managed.
![Page 21: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/21.jpg)
Cogeneration Plant • Installed in 1996 • Produces 1 million
KWH/yr • Saves approx.
$130K/yr in avoided costs
• Cost to install approx. $360K
• Payback less than 3 years
• Maintenance cost to date approx. $38K
![Page 22: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/22.jpg)
Pow er Plant Fue l Consum ed (Therm s) Adjusted for Degree Day
180,000 190,000 200,000 210,000 220,000 230,000 240,000
5 Yr Avg Usage (2002- 2006)
January 2007
Degree Day adjusted fuel savings for January is 29,883 therms. Adjusted fuel savings is $61,180
Ele ctricity Consum ed (KWh)
640,000
680,000
720,000
760,000
800,000
840,000
880,000
5 Yr Avg Usage (2002- 2006)
January 2007
Energy Savings for January is 124,052 Kwh. Savings for January is $17,700.
Monthly Gazette Feature Campus Conservation Efforts
These charts appear monthly in the campus Newsletter to help the community recognize the financial impact of their conservation efforts
![Page 23: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/23.jpg)
Note: During the one month competition, energy reduction of 3.7% could be attributed to personal habit
![Page 24: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/24.jpg)
Questions?
Thank You
![Page 25: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/25.jpg)
Energy Diagnostics throughEnergy Diagnostics through MeteringMetering
in an Auto Manufacturing Facilityin an Auto Manufacturing Facility
Measuring Energy Use to Improve EnergyMeasuring Energy Use to Improve Energy Performance, Power Quality and ReliabilityPerformance, Power Quality and Reliability
Presented by: Gary C Smith,Presented by: Honda of America Mfg., Inc.Gary C Smith, Honda of America Mfg., Inc.March 2007March 2007
![Page 26: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/26.jpg)
Energy Diagnostics through MeteringEnergy Diagnostics through Metering
OVERVIEWOVERVIEW
•Who is Honda •Know your Energy •Efficiency Up •New Technology
![Page 27: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/27.jpg)
![Page 28: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/28.jpg)
Energy Diagnostics through MeteringEnergy Diagnostics through Metering
Know Your Energy
•You cannot manage that which you cannot measure •Know your demand and your consumption •Metering is essential
•Primary Metering •Electricity •Natural Gas •Steam •Compressed Air
The very least metering you have is the Utility metering serving you. The best is a meter on every process. Reality is somewhere in between.
![Page 29: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/29.jpg)
Energy Diagnostics through MeteringEnergy Diagnostics through Metering
Your Meter is yourCash Regi$ter!
![Page 30: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/30.jpg)
Energy Diagnostics through MeteringEnergy Diagnostics through Metering
Know your Energy
•Sub Metering (Metering for departments)•Electricity •Natural Gas •Compressed Air •Steam
•Our goal is to have each department metered separately
In order for a person or department to take accountability and ownership, you have to give them a yardstick!
![Page 31: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/31.jpg)
Energy Diagnostics through MeteringEnergy Diagnostics through Metering
Know your Energy
•What if you do not have the metering? •Calculate •Estimate •Review your history
You can use a portable meter to measure before and after scenarios. Calculations will work nicely for achieving approval for a project but management may want to see the result.
![Page 32: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/32.jpg)
Energy Diagnostics through MeteringEnergy Diagnostics through Metering
The first step(s)
•Metering
•Installing metering on all substations
•Installing the mechanical metering
•Gathering data (computers)
•What to do with the data
•Who should receive the data
You can have the best, most expensive metering in the world. If it isn’t used, it’s worthless.
![Page 33: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/33.jpg)
Process Energy Optimization at Honda
![Page 34: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/34.jpg)
![Page 35: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/35.jpg)
![Page 36: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/36.jpg)
![Page 37: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/37.jpg)
Energy Diagnostics through MeteringEnergy Diagnostics through Metering
51.5 K Total Consumption 60,000
50,000
40,000
30,000
20,000
17.2 K
10,000
0
![Page 38: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/38.jpg)
(KWH/ 台)
0
5,000
10,000
15,000
20,000
25,000
30,000
35,000
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
(KWH)
0.00
5.00
10.00
15.00
20.00
25.00
30.00 (KWH) TP 原単位
Consumption of weekend is about 16% of workday.
![Page 39: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/39.jpg)
![Page 40: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/40.jpg)
![Page 41: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/41.jpg)
![Page 42: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/42.jpg)
![Page 43: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/43.jpg)
![Page 44: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/44.jpg)
![Page 45: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/45.jpg)
![Page 46: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/46.jpg)
![Page 47: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/47.jpg)
![Page 48: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/48.jpg)
![Page 49: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/49.jpg)
Compressor 1 Starting Current
0
500
1000
1500
2000
2500
Time in seconds
Ampe
rage
Measuring Energy Use to Improve Energy PerformanceMeasuring Energy Use to Improve Energy Performance
![Page 50: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/50.jpg)
Energy Diagnostics through MeteringEnergy Diagnostics through Metering
New Technology
•Fuel Cells •Co-Generation •VFD’s •Micro Turbines •Solar technology •Wind power •Increases and improvements in existing technology
In our monthly energy meeting, we, at times, bring in a guest speaker, (vendor), to speak on some type of new technology.
![Page 51: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/51.jpg)
![Page 52: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/52.jpg)
![Page 53: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/53.jpg)
Questions & Discussion
![Page 54: Energy Management Diagnostics Management Diagnostics ... • Steam usage in every building served by the Power Plant. ... • Produces 1 million KWH/yr](https://reader031.vdocuments.net/reader031/viewer/2022022517/5b0979147f8b9a992a8db5ee/html5/thumbnails/54.jpg)
Upcoming Web Conferences
April – Award Wining Energy Programs: The ENERGY STAR Partners of Year
- JC Penney’s
- Davenport IA School District
May – Assessing Facility Energy Management Practices
June – Our Top Three Energy Projects
Download past web conference presentations at: www.energystar.gov/index.cfm?c=networking.bus_networking
Questions or comments? Contact: [email protected]