engines b777- - pmgasser · 2021. 5. 28. · f b777-300er = electrical legend ac busses other...

1
NOT FOR OPERATIONAL USE !!! Left HYD (Lemon) Center HYD (Cyan) Right HYD (oRange) Fuel Manifold APU Fuel Manifold Electrical Bleed Air Hot Air Conditioning Mechanical/other ACEs (Color of HYD sys) Non return Valve Pump Valve HYD motor Mechanical HYD Pump Electrical HYD Pump Pneumatical HYD Pump Ventilation Fan Smoke Detector Fire extinguisher bottle LEGEND L2 S F B777- 300ER = ELECTRICAL LEGEND OTHER SYSTEMS AC Busses DC Busses Normal In-flight feed Alternate feeds Backup AC PWR Standby Battery only Standby with RAT 20.2.2020, Pierre-Michel Gasser, www.pmgasser.ch Length to elevator: 73.86m to tail: 73.08m Price 375 million $ MZFW 239’950 kg MTW 352’441 kg MTOW 351’535 kg MLW 251’290 kg Fuselage Width 6.2m Width 64.80m Wing tip turn radius 48.80m Minimum width for 180° turn 56.50m Height: 18.85m Gear to gear Outer track 12.90m Nose wheel to main gear 31.22m C L2 L2 L2 M R R R C L2 L1 L1 L1 C C R FLAP -ERON 10 11 12 13 14 R AILERON R 8 9 C R L2 L2 R C L2 L1 C L1 L FLAP -ERON 5 4 3 2 1 L AILERON R 7 6 L1 L1 C L2 ALTN PITCH TRIM Lever R L2 C L ELEVATOR R ELEVATOR R Stabilizer R L1 C RUDDER TAB FLIGHT CONTROLS Actuator Control Electronics FLAPS & SLATS PRIMARY - Center Hydraulic - Flap load relief, Autoslat - Asymetry/uncommanded motion SECONDARY [ ] FLAPS PRIMARY FAIL [ ] FLAP/SLAT CONTROL - Electric, L and R AC BUS via FSEU - Slat load relief >256kts - Asymetry/uncommanded motion ALTERNATE - Electric, L and R AC BUS, direct AP Primary Flight Computers Power Supply Assembly L DC BUS M M L MAIN AC BUS FLAPS MOTORS R MAIN AC BUS L ENG GEN PMG R DC BUS ARINC F/CTL DATA BUS ANALOG SIGNALS R ENG GEN PMG HOT BAT BUS 1 Min. BATTERY CAPT FLT INST BUS L ENG GEN PMG R ENG GEN PMG HOT BAT BUS 1 Min. BATTERY 1 Min. BATTERY For colors see ELECTRICAL Legend ACE ACE PFC PFC PSA PFC-L PFC-C PFC-R AFDS-R AFDS-C AFDS-L L FCDC BUS PSA-L C FCDC BUS PSA-C R FCDC BUS PSA-R ACE PFC MECHANICAL BACKUP SPOILER 4 + 11 STABILIZER ALTN PITCH TRIM ACE - Stall protection - Overspeed protection - Elevator variable feel - Tailstrike protection - Trim reference speed with automatic pitch compensation for thrust, gear, flaps and speedbrakes changes, turbulence and turns to 30° bank - Proportional elevator command - Elevator feel with 2 feel forces - Both trim switch move directly the stabilizer - no automatic speedbrakes - pitch control same as secondary mode - only Rudder trim, no cancel switch - Bank protection 35° ->30° - Yaw Damper - Thrust Assymetry Comp. - Wheel to rudder x-tie - Gust suppression - Rudder trim - Rudder trim cancel switch - automatic speedbrakes - Spoilers 4,5,10,11 locked out - Degraded yaw damping - Rudder trim - Rudder trim cancel switch M CENTER HYD L MAIN AC BUS SLATS MOTORS R MAIN AC BUS CENTER HYD NORMAL MODE SECONDARY MODE DIRECT MODE A/P L STCM R STCM [ ] FLIGHT CONTROL MODE [ ] PRI FLIGHT COMPUTERS RAT C1 C1 ISOL ISOL Nose GEAR & STEER ALTN/RSV BRAKES FLT CTLS FLAPS & Main GEAR NORM BRK FLT CTL R REV = = C2 C2 AIR SOV R ENG R ELEC DMD FLT CTL L REV SOV L ELEC DMD L ENG CENTER HYD LEFT HYD RIGHT HYD L Jettison Nozzle VLV L Jettison PMP L Surge Tank L ENG FUEL SPAR VLV L ENG FUEL VLV Fuel nozzles manifolds 20 outer 10 inner , OFF in idle des General Electric GE90-115B 1st stage ENG fuel pump 2nd stage ENG fuel pump OIL / Fuel Heat exchanger Fuel filter Fuel Metering Unit DC APU PMP CTR L Override Jettison Pump L AFT PMP L FWD PMP APU Isol. VLV CTR L Jettison VLV L Main Tank 31’300 Kg APU Shut off VLV Right Fuel SYS same as Left without APU pump, valves and lines X-feed VLVs Tanks - Main Tanks 31’300kg each - Center tank 82’900kg - Total 145’500kg usable Preflight: - Center Pumps ON if FUEL IN CENTER and more than 4800kg in center Inflight: - FUEL LOW CENTER -> switch OFF pumps - after 45min, scavenge of the 1200kg fuel remaining in center tank in around 90min with the main jettison pumps. Jettison: - rate 2500 kg/min with center tank - rate 1400kg/min without center tank - at least 3800kg remain in each main tank FUEL ENGINES APU 1300 1500 1700 1900 2100 2041kg 40’823kg 55’791kg 1360kg 30 40 Total main tank fuel [t] Max. Imbalance, only for Normal OPS Imbalance [kg] 50 60 70 Center Tank 82’900 Kg - 27 million US$ - T/O Thrust max 115’540lbs / 513KN / ~110’000hp - MCT Thrust 110’000lbs - 1 FAN, 4 LP + 9 HP comp, 2 HP + 6 LP turbine - 22 carbon fiber fan blades - bypass ratio 9:1 - pressure ratio 42:1 - Thrust to weight ratio 6:1 - weight 8762kg - fan diameter 330 cm, engine length 728cm - N1 100% = 2355 RPM, limit 110.5% = 2602 RPM - N2 100% = 9332 RPM, limit 121% = 11292 RMP - EGT max 1090°C, 30 sec. 1095°C, MCT max 1050°C - Oil temperature, max 132°C, 15min 143°C - 2 Fire Ext bottles shared for both engines - 3 Starts in 60min for each starter, electrical and air driven - auto start if both AC XFR BUS lost - 200kg/h APU GEN on GND - 20kg/h per Pack on GND - 150kg/h at FL380 - APU BLEED available <22’000ft - 1 Fire Ext bottle for APU - on GND & ENG OFF => Auto Fire Ext 4th, Low Press Bleed - FWD and AFT outflow valves - CAC, Cabin Altitude Controller - 2 positive relief valves, opens at 9.1 psi - 4 negative relief valves 9th, High Press Valve PRSOV Pressure Regulating and Shut Off Valve 7th, Anti Ice Valve L Pack Bleed Isol Valves Trim Air Pressure & Shut Off Valves ABCDEF Cabin Zones Flight Deck Conditioned Air Manifold Main Eqmt Center L C R Fan Air Precooler ENG Starter Valve R Wing Anti Ice Valve R Pack Lower Recirculation Fans Upper Recirculation Fans Zone Trim Air Valves Supply Fans Airplane Skin Air Filter Cabin Air Override Valve Vent Fan Vent Valve FWD Outflow Valve Cargo Heat Valve L R ACM Air Cycle Machine Bypass Valve Flow Control & Shut OFF Valves Heat Exchangers FWD Eqmt Center Flight Deck AFT Outflow Valve FWD Cargo Heating Cooling S S S S Bleed system left wing identical to right wing AFT Cargo to FWD Cargo Rapid bottles Metered Bottles S S S S Bulk Cargo F F F F F F CARGO FIRE AIR OVERRIDE mode [] EQUIP COOLING OVRD - Supply fans stop - Override valve close to supply and opens the skin exhaust - Vent fan stops - Cargo Heat Valve close, Vent Valve opens - Smoke is evacuated outboard per differential pressure Equipment Cooling, normal mode - Supply fan runs, R primary, L backup - Override valve open to supply and close to the skin exhaust - Vent fan runs - Vent valve opens if TAT >12.8°C - Cargo valve opens if the Vent valve closes (mechanically linked) APU Bleed VLV APU Starter VLV APU ENG BLEED SYSTEM PRESSURIZATION AIR CONDITIONING EQUIPMENT COOLING S S Packs - CACTCS (Cabin Air Conditioning and Temperature Control System) - Each pack has fully redundant dual channel - Flow Control & Shut Off Valves operate pneumatically, are springloaded close without pressure. Without control from ASCPC, valve opens with pressure. - Pack can operate in stanby cooling mode [] PACK MODE L,R - Loss of trim air, CACTCS will provide average temp 100 50 100 150 200 250 300 350 400 150 200 250 300 350 400 FL Decompression Profile [NM] - 1’ at CRZ FL - 1‘ des to FL 290 - 4’ level at FL 290 - 1‘ des to FL 250 - 12’ level at FL 250 - 3‘ des FL 140, total 22’ ~177NM no wind F L MAIN BUS STBY BUS APU BAT BUS HOT BAT BUS BAT BUS L MAIN DC BUS R MAIN DC BUS CAPT FLT INST BUS F/O FLT INST BUS R XFR BUS GND SERVICE BUS L GEN L BUS TIE MAIN & APU GEN 120kVA BACKUP GEN 25kVA TRUs 120A R BUS TIE TO PSA TO PSA TO PSA TO PSA TO PSA TO PSA APU GEN RAT GEN EXT SEC APU BAT CHARG APU BAT CHARG L TRU C1 TRU C2 TRU STBY INVERTER R TRU EXT PRI L Backup GEN L PMG L IDG R Backup GEN R PMG R ENG Gearbox L ENG Gearbox R GEN L XFR BUS L UTIL R UTIL RAT ELECTRICAL DC AC BACKUP Power when : - only 1 main AC GEN available, or - one or both main AC busses is lost, or - APP mode is selected for autoland RAT deploys if - both engines are failed and center system pressure is low, or - both AC transfer busses are unpowered, or - all three hydraulic system pressures are low R IDG R MAIN BUS CONVERTER 400 Hz ONLY 1 GEN APU BAT MAIN BAT

Upload: others

Post on 12-Aug-2021

79 views

Category:

Documents


8 download

TRANSCRIPT

Page 1: ENGINES B777- - pmgasser · 2021. 5. 28. · F B777-300ER = ELECTRICAL LEGEND AC Busses OTHER SYSTEMS DC Busses Normal In-flight feed Alternate feeds Backup AC PWR Standby Battery

NOT FOR OPERATIONAL USE !!!

Left HYD (Lemon)Center HYD (Cyan)

Right HYD (oRange)Fuel Manifold

APU Fuel ManifoldElectrical

Bleed Air HotAir Conditioning

Mechanical/otherACEs (Color of HYD sys)

Non return ValvePumpValve

HYD motorMechanical HYD Pump

Electrical HYD PumpPneumatical HYD Pump

Ventilation FanSmoke Detector

Fire extinguisher bottle

LEGEND

L2S

F

B777-300ER

=

ELECTRICAL LEGEND

OTH

ER S

YST

EMS

AC BussesDC BussesNormal In-flight feedAlternate feedsBackup AC PWRStandby Battery onlyStandby with RAT

20.2.2020, Pierre-Michel Gasser, www.pmgasser.ch

Lengthto elevator: 73.86mto tail: 73.08m

Price 375 million $

MZFW 239’950 kgMTW 352’441 kgMTOW 351’535 kgMLW 251’290 kg

FuselageWidth

6.2m

Width64.80m

Wing tipturn radius48.80m

Minimum widthfor 180° turn56.50m

Height: 18.85m

Gear to gearOuter track12.90m Nose wheel

to main gear31.22m

C

L2 L2L2

MR

R

RCL2L1

L1

L1C

CR FLAP-ERON 10

1112

1314

R AILERON

R

8 9

C

RL2L2

R

C

L2

L1C

L1L FLAP-ERON5

43

21

L AILERON

R

76

L1

L1 C L2

ALTN PITCHTRIM Lever

R

L2

C

L ELEVATOR R ELEVATOR

R

Stabilizer

R

L1

C RUD

DER

TAB

FLIGHT CONTROLS

ActuatorControlElectronics

FLAPS & SLATSPRIMARY - Center Hydraulic

- Flap load relief, Autoslat- Asymetry/uncommanded motion

SECONDARY

[ ] FLAPS PRIMARY FAIL

[ ] FLAP/SLAT CONTROL

- Electric, L and R AC BUS via FSEU- Slat load relief >256kts- Asymetry/uncommanded motion

ALTERNATE - Electric, L and R AC BUS, direct

AP

PrimaryFlightComputersPowerSupplyAssembly

L DC BUS

M

M

L MAIN AC BUS

FLAPSMOTORS

R MAIN AC BUS

L ENG GEN PMGR DC BUS

ARINCF/CTL DATA BUS

ANALOG SIGNALS

R ENG GEN PMGHOT BAT BUS1 Min. BATTERY

CAPT FLT INST BUSL ENG GEN PMG

R ENG GEN PMGHOT BAT BUS1 Min. BATTERY

1 Min. BATTERY

For colors see ELECTRICAL Legend

ACE

ACE

PFC

PFC

PSA

PFC-L PFC-C PFC-R

AFDS-RAFDS-C

AFDS-L

L FCDC BUSPSA-L

C FCDC BUSPSA-C

R FCDC BUSPSA-R

ACE

PFC

MECHANICAL BACKUP

SPOILER 4 + 11

STABILIZERALTN PITCH TRIM

ACE

- Stall protection- Overspeed protection- Elevator variable feel- Tailstrike protection- Trim reference speed with automatic pitch compensation for thrust, gear, flaps and speedbrakes changes, turbulence and turns to 30° bank

- Proportional elevator command- Elevator feel with 2 feel forces- Both trim switch move directly the stabilizer- no automatic speedbrakes

- pitch control same as secondary mode- only Rudder trim, no cancel switch

- Bank protection 35° ->30°- Yaw Damper- Thrust Assymetry Comp.- Wheel to rudder x-tie- Gust suppression- Rudder trim- Rudder trim cancel switch- automatic speedbrakes

- Spoilers 4,5,10,11 locked out- Degraded yaw damping- Rudder trim- Rudder trim cancel switch

M

CENTER HYD

L MAIN AC BUS

SLATSMOTORS

R MAIN AC BUS

CENTER HYD

NORMAL MODE

SECONDARY MODE

DIRECT MODE

A/P

L STCM R STCM

[ ] FLIGHT CONTROL MODE

[ ] PRI FLIGHT COMPUTERS

RAT

C1C1

ISOL ISOL

No

se G

EAR

& S

TEER

ALT

N/R

SVB

RA

KES

FLT

CTL

S

FLA

PS &

Mai

n G

EAR

NO

RMB

RK

FLT

CTL

R RE

V

= =

C2C2

AIR

SOV

RENG

RELECDMD

FLT

CTL

L RE

V

SOV

LELECDMD

LENG

CENTERHYD

LEFTHYD

RIGHTHYD

L JettisonNozzle VLV

L Jettison PMP

L SurgeTank

L ENG FUELSPAR VLV

L ENG FUEL VLV

Fuel nozzles manifolds20 outer

10 inner , OFF in idle des

General Electric GE90-115B

1st stage ENG fuel pump

2nd stage ENG fuel pump

OIL / Fuel Heat exchanger

Fuel filter

Fuel Metering Unit

DCAPUPMP

CTR L OverrideJettison Pump

L AFT PMP

L FWD PMP

APUIsol.VLV

CTR L Jettison VLV

L Main Tank31’300 Kg

APUShut off

VLV

Right Fuel SYSsame as Leftwithout APUpump, valvesand lines

X-feed VLVs

Tanks - Main Tanks 31’300kg each - Center tank 82’900kg - Total 145’500kg usablePreflight: - Center Pumps ON if FUEL IN CENTER and more than 4800kg in centerInflight: - FUEL LOW CENTER -> switch OFF pumps - after 45min, scavenge of the 1200kg fuel remaining in center tank in around 90min with the main jettison pumps. Jettison: - rate 2500 kg/min with center tank - rate 1400kg/min without center tank - at least 3800kg remain in each main tank

FUEL

ENGINES

APU

1300

1500

1700

1900

21002041kg

40’823kg

55’791kg1360kg

30 40Total main tank fuel [t]

Max. Imbalance, only for Normal OPS

Imb

alan

ce [k

g]

50 60 70

Center Tank82’900 Kg

- 27 million US$- T/O Thrust max 115’540lbs / 513KN / ~110’000hp- MCT Thrust 110’000lbs- 1 FAN, 4 LP + 9 HP comp, 2 HP + 6 LP turbine- 22 carbon fiber fan blades- bypass ratio 9:1- pressure ratio 42:1- Thrust to weight ratio 6:1- weight 8762kg- fan diameter 330 cm, engine length 728cm- N1 100% = 2355 RPM, limit 110.5% = 2602 RPM- N2 100% = 9332 RPM, limit 121% = 11292 RMP- EGT max 1090°C, 30 sec. 1095°C, MCT max 1050°C- Oil temperature, max 132°C, 15min 143°C- 2 Fire Ext bottles shared for both engines

- 3 Starts in 60min for each starter, electrical and air driven- auto start if both AC XFR BUS lost- 200kg/h APU GEN on GND- 20kg/h per Pack on GND- 150kg/h at FL380- APU BLEED available <22’000ft- 1 Fire Ext bottle for APU- on GND & ENG OFF => Auto Fire Ext

4th, Low Press Bleed - FWD and AFT outflow valves- CAC, Cabin Altitude Controller- 2 positive relief valves, opens at 9.1 psi- 4 negative relief valves

9th, High Press Valve

PRSOV Pressure Regulatingand Shut Off Valve

7th, Anti Ice ValveL

Pack

Bleed Isol Valves

Trim Air Pressure & Shut Off Valves

A B C D E FCabin ZonesFlight

Deck

ConditionedAir Manifold

Main EqmtCenter

L C R

Fan Air Precooler

ENG Starter Valve

R Wing Anti Ice Valve

R Pa

ck

Lower Recirculation Fans

Upper Recirculation Fans

Zone Trim Air Valves

Supply FansAirplane Skin

Air Filter

CabinAir

Override ValveVent Fan

Vent Valve

FWDOutflow

ValveCargoHeatValve

L R

ACM Air Cycle MachineBypass Valve

Flow Control & Shut OFF ValvesHeat Exchangers

FWD EqmtCenter

FlightDeck

AFTOutflow Valve

FWD Cargo

Heating

Cooling

S

S

S

S

Bleed systemleft wingidenticalto rightwing

AFT Cargo

toFWD

CargoRapid

bottles

MeteredBottles

S

S

S

SBulk Cargo

F

F

F F

F

F

CARGO FIRE

AIR

OVERRIDE mode [] EQUIP COOLING OVRD - Supply fans stop - Override valve close to supply and opens the skin exhaust - Vent fan stops - Cargo Heat Valve close, Vent Valve opens - Smoke is evacuated outboard per differential pressure

Equipment Cooling, normal mode - Supply fan runs, R primary, L backup - Override valve open to supply and close to the skin exhaust - Vent fan runs - Vent valve opens if TAT >12.8°C - Cargo valve opens if the Vent valve closes (mechanically linked)

APUBleedVLV

APUStarterVLV

APU

ENG BLEED SYSTEM PRESSURIZATION

AIR CONDITIONING

EQUIPMENTCOOLING

SS

Packs - CACTCS (Cabin Air Conditioning and Temperature Control

System) - Each pack has fully redundant dual channel - Flow Control & Shut Off Valves operate pneumatically, are

springloaded close without pressure. Without control from ASCPC, valve opens with pressure.

- Pack can operate in stanby cooling mode [] PACK MODE L,R

- Loss of trim air, CACTCS will provide average temp

10050 100 150 200 250 300 350 400

150

200

250

300

350

400FL

DecompressionProfile

[NM]

- 1’ at CRZ FL- 1‘ des to FL 290- 4’ level at FL 290- 1‘ des to FL 250- 12’ level at FL 250- 3‘ des FL 140, total 22’ ~177NM no wind

F

L MAIN BUS

STBY BUSAPU BAT BUS

HOT BAT BUS

BAT BUS

L MAIN DC BUS R MAIN DC BUSCAPT FLT INST BUS F/O FLT INST BUS

R XFR BUS

GND SERVICE BUS

LGEN

LBUSTIEMAIN & APU

GEN 120kVA

BACKUPGEN 25kVA

TRUs120A

RBUSTIE

TOPSA

TOPSA

TOPSA

TOPSA

TOPSA

TOPSA

APUGEN

RATGEN

EXTSEC

APU BATCHARG

APU BATCHARG

LTRU

C1TRU

C2TRU

STBYINVERTER

RTRU

EXTPRI

LBackup

GEN

LPMG

LIDG

RBackup

GEN

RPMG

R ENG GearboxL ENG Gearbox

RGEN

L XFR BUS

L UTIL R UTIL

RAT

ELECTRICAL

DC

AC

BACKUP Power when :- only 1 main AC GEN available, or- one or both main AC busses is lost, or- APP mode is selected for autoland

RAT deploys if - both engines are failed and center system pressure is low, or- both AC transfer busses are unpowered, or- all three hydraulic system pressures are low

RIDG

R MAIN BUS

CONVERTER400 Hz

ONLY 1 GEN

APUBAT

MAINBAT