enhanced critical infrastructure protection (ecip) facility dashboard november 2009

19
Enhanced Critical Infrastructure Protection (ECIP) Facility Dashboard November 2009

Upload: alexander-graham

Post on 27-Mar-2015

218 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Enhanced Critical Infrastructure Protection (ECIP) Facility Dashboard November 2009

Enhanced Critical Infrastructure Protection (ECIP) Facility Dashboard

November 2009

Page 2: Enhanced Critical Infrastructure Protection (ECIP) Facility Dashboard November 2009

Infrastructure Survey Tool (IST) Development Began in June 2008

Pilot (Summer 2008) Version 1 (Fall 2008) Version 2 (Summer 2009)

Web-based Tool Collects Data Streamlines data collection Oracle back end database Supports analysis and Dashboard

Major Principles Simply a survey of existing protective

measures in place at the facility Gathers data at the weakest point for

any particular protective measure (e.g., the shortest part of the fence or the one gate with the single lock)

2

Resulting Protective Measures Index (PMI) is calculated using the relative importance assigned to each protective measure attribute by a team of subject matter experts

Page 3: Enhanced Critical Infrastructure Protection (ECIP) Facility Dashboard November 2009

Protective Measures Index (PMI) - Review

Based on Six “Level 1 Components” 1. Physical Security

2. Security Management

3. Security Force

4. Information Sharing

5. Protective Measures Assessment

6. Dependencies

Each of these components is based on “Level 2 Components”

Level 2 Components are, in turn, based on the most detailed asset characteristics, which are “Level 3 Components” for the facility (at the weakest point)

3

Page 4: Enhanced Critical Infrastructure Protection (ECIP) Facility Dashboard November 2009

4

IST Level 1 and Level 2 Components

Page 5: Enhanced Critical Infrastructure Protection (ECIP) Facility Dashboard November 2009

Fences Gates Closed circuit television (CCTV) Intrusion detection systems (IDS) Parking Access control Security lighting Vehicle access control Building envelope

For Example, There Are 9 Physical Security Level 2 Components:

5

Page 6: Enhanced Critical Infrastructure Protection (ECIP) Facility Dashboard November 2009

Similarly, Fences has Several Level 3 Components (Detailed Characteristics)

Fraction enclosed Fence type Height Base anchored Other fence characteristics

Clear zone Warning signs Free of objects Outriggers Enhancements (e.g., barbed wire) Vehicle protection Constant illumination Triggered illumination

6

Page 7: Enhanced Critical Infrastructure Protection (ECIP) Facility Dashboard November 2009

Level 3 Components Affect Vulnerability (Fences Example)

Fence Protective Measures Index = f (fraction enclosed, type, height, base anchored, other fence characteristics)

FPMI = f (z1, z2, ..., zn) = bi * zi

i = 1

FPMI is a protective measures index of fence security going from 0 (less secure) to 100 (more secure), the zi represent specific levels of achievement for the factors that increase fence security (e.g., height, type, characteristics), and the bi are scaling constants (weights) that specify the relative importance of the factors.

(Note: the equation may take on a different form)

7

Additional information can be found at Constructing Vulnerability and Protective Measures Indices for the Enhanced Critical Infrastructure Protection Program by R.E. Fisher, W.A. Buehring, et al., October 1, 2009.

Page 8: Enhanced Critical Infrastructure Protection (ECIP) Facility Dashboard November 2009

8

Fences PMI Has Many Components

Fence Characteristics Rank RI Outriggers Outriggers: 45 degree 1 100

Outriggers: Y style 2 90Outrigger: Straight up 3 80No Outrigger 4 0

Enhancements Rank RIBarbed wire 5 70Broken glass 8 30Spikes 7 60Razor wire 4 80Reinforced anchor points 1 100Electric Fence 1 100Mesh Kevlar 1 100Second Fence 5 70Screening 5 70

Worst Level Best Level Rank RIClear Zone No Yes 6 40

Warning Signs No Yes 7 25Free of Objects No Yes 4 50

Vehicles None All 2 95Illumination No Yes 3 60Triggered

Illumination No Yes 5 45Characterize None All 1 100

Other Fence Characteristics Summary

8

Page 9: Enhanced Critical Infrastructure Protection (ECIP) Facility Dashboard November 2009

7-foot aluminum chain-link fence

Anchored base Outriggers, 45 degree Barbed wire Clear zone, free of objectsFence Protective Measures

Index = 60

Fences PMI Example

Wood fence 6-foot height Partial clear zone

Fence Protective Measures Index = 13

9

Page 10: Enhanced Critical Infrastructure Protection (ECIP) Facility Dashboard November 2009

Comparing Facility and Subsector

Facility PMI

10

Subsector Maximum

Subsector Average

Subsector Minimum

Overall Facility PMI

Page 11: Enhanced Critical Infrastructure Protection (ECIP) Facility Dashboard November 2009

Dashboard – Overall Tab “Overall” tab shows the overall facility PMI and the PMIs for

each major component (Level 1) of the facility PMI (blue bar) and the low, average, and high PMI for the subsector (dots). Touch on the bar or dots to see the exact PMI figures.

11

Page 12: Enhanced Critical Infrastructure Protection (ECIP) Facility Dashboard November 2009

Dashboard – Component Screens

Level 2 Components

Level 3 Data

Level 3 Component PMI

• Overall PMI Bar

•Level 1 PMI Bar

•Level 2 PMI Dial

Tabs – Level 1

12

Page 13: Enhanced Critical Infrastructure Protection (ECIP) Facility Dashboard November 2009

Dashboard Buttonology The IST Level 1 Components are shown as tabs across the

top. Touching a tab opens to the PMIs for each of the Level 2 and 3 Components within that section.

The dark blue bar is the PMI for the answer in the IST (Facility: Existing)

The light blue bar (Facility: Scenario) moves to reflect changes to the PMI based on manipulation of the buttons to reflect different scenarios.

The subsector average PMI is shown in grey.

A dial to the left indicates the existing PMI for that Level 2 section (e.g. CCTV); it moves to show the scenario PMI when changes have been made to the Level 3 answers.

The bars above the dial show the Overall Facility PMI and Level 1 PMI (e.g., Physical Security) - black is existing and does not move, and blue moves to show the changes from the scenario selected.

13

Page 14: Enhanced Critical Infrastructure Protection (ECIP) Facility Dashboard November 2009

Dashboard Buttonology (cont’d)

For Yes/No questions, the dark blue bar will not be visible if the answer input is “No.” If the answer input is “Yes,” the bar will extend all the way to the right.

14

Page 15: Enhanced Critical Infrastructure Protection (ECIP) Facility Dashboard November 2009

Dashboard Buttonology (cont’d)

Touching a button at the left will open the Level 3 questions.

Level 3 buttons can be manipulated to either show data corrections or demonstrate different scenarios for the Facility to “try.”

The bars and dials will change accordingly.

15

Page 16: Enhanced Critical Infrastructure Protection (ECIP) Facility Dashboard November 2009

Dashboard Interpretation The Dashboard is a way to display facility-specific information

obtained through the ECIP Shows the PMI calculations for each component of the IST

PMI has a constructive sense in that it increases (gets better) as protective measures are added

The Dashboard shows the difference between the individual facility’s specific PMI and the average PMI for other like facilities (usually the critical infrastructure subsector)

The product should not give the impression that the subsector average PMIs are indicative of desired or adequate performance

16

Page 17: Enhanced Critical Infrastructure Protection (ECIP) Facility Dashboard November 2009

Dashboard Interpretation (cont’d) The Dashboard draws attention to components that are well

below or well above the subsector average and may deserve additional study.

There may be very good reasons why a facility has a component PMI that is below subsector average.

Example: An urban facility where parking is allowed on the street would result in a low standoff number; no additional facility action may be possible

May just note the vulnerability and consider other protective measures enhancements (e.g., additional CCTV along the facility street-side to identify suspicious vehicles)

Each facility is different and will mitigate vulnerabilities and implement protective measures based on an individualized assessment of risks taking into consideration threat, assets to be protected, and facility characteristics.

17

Page 18: Enhanced Critical Infrastructure Protection (ECIP) Facility Dashboard November 2009

Dashboard is a Tool The Dashboard is simply a tool, and the PMI is simply a

reflection of existing protective measures at the facility, not a definitive determination of facility vulnerability.

DHS is not advocating that any particular protective measures be installed/utilized at a facility based solely on the relative impact to the facility’s PMI reflected in the scenario element of the Dashboard.

It is recognized that not all protective measures are appropriate at every facility. Therefore, simply raising the PMI for a section in the Dashboard is not necessarily directly correlated to a reduction in vulnerability for a particular facility unless it is an appropriate measure that is properly integrated with the facility’s current security posture and effectively implemented.

18

Page 19: Enhanced Critical Infrastructure Protection (ECIP) Facility Dashboard November 2009

Questions and Comments

19