enlighten home inspections, llc - sample website report
TRANSCRIPT
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
1/67
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
2/67
Table of Contents
Cover Page
Table of Contents
Intro Page
1 STRUCTURE
2 EXTERIOR
3 PLUMBING
4(A) ELECTRIC - GARAGE/EXTERIOR
4(B) ELECTRIC - UTILITY ROOM/INTERIOR
5(A) HVAC - UPPER LEVEL
5(B) HVAC - BASEMENT
6 INTERIOR
7(A) KITCHEN - BASEMENT
7(B) KITCHEN - MAIN LEVEL
Minor Discovery Summary
MAJOR Discovery Summary
General Summary
CliEnlighten Home Inspections, LLC
Page 2 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
3/67
Date: 4/30/2013 Time: 10:00 AM Report ID: SampleWebsite
Property:
Sample StreetSample Report VA
Customer:
Sample ClientReal Estate Professional:
Sample AgentSample Realty
Enlighten Home Inspections, LLC is pleased to provide you with this home inspection report. This report is intended toprovide you with an evaluation of the general condition of the home on the date of the inspection. Please read the entire
report. The areas of the home that were inspected include: Structure, Exterior, Plumbing, Electric, HVAC (Heating,Ventilation and Air Conditioning), Interior and Kitchen. For condominiums and cooperatives, common areas are NOTinspected and are not part of a standard report. The structure and exterior are considered common areas in condominiumsand cooperatives.
The focus of the inspection was on major problems or concerns. A major problem or concern is a component that issignificantly deficient and would potentially cost $500.00 to repair or replace, or posses a threat to life or health. Theseitems, if any, are contained in this report and can be easily identified by locating an "X" in the "MA" (Major) column in eachsection of this report. Look for the description of the problem or concern in the corresponding explanation below thecolumns. Major problems or concerns can also be accessed by looking directly at the "MAJOR" Summary in this report.
During the course of identifying major problems or concerns, it is nearly inevitable that minor problems or concerns will belocated. A minor problem or concern is a component that is deficient and would more than likely cost less than $500.00 torepair or replace. Minor problems or concerns can be easily identified by locating an "X" in the "m" (minor) column in eachsection of this report. Look for the description of the problem or concern in the corresponding explanation below thecolumns. Minor problems or concerns can also be accessed by looking directly at the "MINOR SUMMARY" in this report. Iis important to note that this inspection is not an all inclusive inspection and not every minor defect is noted in this report.
It is my sincere hope that you find this report and our services to be beneficial. Thank you for choosing Enlighten HomeInspections, LLC for your home inspection needs.
Regards,
Isaac Kieffer
Enlighten Home Inspections, LLC
Style of residence:Detached residence Client is present:Yes Year Built:1970
Radon Test:Yes
Weather:Partly cloudy
Temperature:75
Precipitation in the last 3 days:Yes - rain
Client attention:Complete
Others present:Buyer's agent, Family member(s)
Occupied:No
CliEnlighten Home Inspections, LLC
Page 3 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
4/67
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
5/67
2. EXTERIOR
Recommended that a licensed general contractor perform all repairs noted in this section.
Styles & Materials
ACCESS:Typical
MAIN ROOF:ACCESS: Viewed from groundACCESS: Viewed from roof edgeROOF INACCESSIBLE - Breakableroofing materialLAYERS: 1ROOFING MATERIAL: Slate
AGE: 30+ yearsSLOPE: ModerateOVERALL CONDITION: GoodPROBABILITY OF REPLACEMENT: Low
ROOF COVERING 2:ROOF LOCATION: Carport
SITE/DRAINAGE:GUTTERS: AluminumGUTTERS: AttachedCOMPONENT: DownspoutsCOMPONENT: Underground drain(s) -unable to inspectSURFACE CONTROLS: French drainSURFACE CONTROLS: Retaining wall(s)
SURFACE CONTROLS: Window well(s)SITE: Above street levelSITE: Ponding/wet areasSITE: Yard slopes toward houseGRADING/DRAINAGE CONTROLS:Improvement(s) needed
SIDING MATERIAL:BrickStone
TRIM MATERIAL:Wood
CHIMNEY:TYPE: StoneLOCATION: GableLOCATION: Ridge
ATTACHMENTS:Bay windowCarportPatioPorch
DRIVEWAY:Asphalt
GARAGE DOOR(S):Motorized door operator with release and
auto reverse/stop
OTHER FEATURES:Fencing
Large tree(s)Water feature - not inspected
CliEnlighten Home Inspections, LLC
Page 5 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
6/67
IN NI MA m RR FYI
2.0 ROOF COVERING
2.1 ROOF DRAINAGE
2.2 ROOF FLASHING
2.3 SIDING
2.4 TRIM
2.5 MASONRY
2.6 CHIMNEY(S)
2.7 EXTERIOR DOOR(S)
2.8 SAFETY RAILS
2.9 STEPS/STAIRS
2.10 DRIVEWAY
2.11 GARAGE DOOR(S)
2.12 WALKWAY(S)
2.13 PATIO
2.14 LANDSCAPING
2.15 EXTERIOR DRAINAGE
2.16 DRIVEWAY DRAIN
2.17 RETAINING WALL(S)
2.18 WINDOW WELL(S)
2.19 FENCE(S)
2.20 FOR YOUR INFORMATION
IN NI MA m RR FYI
IN= Inspected - OK at inspection, NI= Not Inspected, MA= Major problem, m= Minor problem, RR= Repair or Replace, FYI= For Your Information
Comments:
2.0 MONETARY CONCERN: Damaged/missing/aged slate: Main roof back side (Pictures 1-5) - consult a licensedroofing contractor
2.1 Improper drainage/damaged underground drain: Downspouts (Picture 1) - recommend extending downspouts a
minimum of 8-10 feet away from the foundation walls, further if possible. Use smooth wall pipe for extensions
2.3 Seal siding at penetration points: Multiple areas (Pictures 1, 2) - recommend sealing all siding penetrations with
duct seal
2.5 Eroded/cracked/missing mortar: Multiple areas (Pictures 1-16) - point up
2.6 (1) Missing flue cap and screen: Left chimney (Picture 1), Rear patio fireplace (Picture 2)
2.6 (2) Cracked crown: Right chimney (Picture 3)
CliEnlighten Home Inspections, LLC
Page 6 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
7/67
2.7 SAFETY CONCERN: Double cylinder deadbolt: Basement (Picture 1), Front door (Picture 2) - recommend
replacing with a deadbolt that is operable from the interior without a key
2.8 (1) SAFETY CONCERN - Missing hand rail: Front left stairs (Picture 1), Right side (Picture 2), Backyard(Picture 3) - handrails should be continuous along the entire length of the stairs
2.8 (2) SAFETY CONCERN - Loose hand/safety rail: Left side stairs (Picture 4)
2.14 MONETARY CONCERN - Large tree(s) overhanging: Multiple trees (Picture 1) - keep branches trimmed awayfrom roof and house
2.15 Ponding/wet areas: Front (Picture 1) - maintain a positive flow of surface water away from foundation walls
2.16 Clogged/debris: Driveway drain (Picture 1) - snake
2.17 SAFETY CONCERN - Retaining walls bowed/pulling away from the house: Back left side (Pictures 1, 2) -
monitor
2.20 For your information: Clean debris from window well(s) to allow water to drain quickly (Picture 1)
CliEnlighten Home Inspections, LLC
Page 7 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
8/67
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
9/67
3.2 (3) Clogged/slow drain: Jack and Jill bathroom bathtub (Picture 4), Upper level bathroom sink (Picture 5),Upper level bathroom bathtub (Picture 6)
3.3 Faucet leaks: Jack and Jill bathroom shower head (Picture 1), Upper level bathroom shower head (Picture 2)
3.4 (1) Corroded valve(s): Utility room washer cold water line (Picture 1), Main level kitchen sink ice maker shut-off(Picture 2)
3.4 (2) Valves leak: Basement bathroom shower (Picture 3), Entryway bathroom sink cold water handle (Picture 4),Jack and Jill bathroom toilet (Picture 5)
3.4 (3) Hot and cold handles reversed: Basement bar sink (Picture 6)
3.5 Missing pop-up drain: Basement bathroom sink (Picture 1)
3.7 (1) Missing/cracked caulk: Bathtub(s)/shower(s) at the tile and floor (Picture 1)
3.7 (2) Cracked tiles: Basement bathroom (Pictures 2, 3)
3.7 (3) Cracked grout: Jack and Jill bathroom bathtub tiles (Picture 4)
3.9 For your information: Freeze vulnerable pipes - Rear hose bibb (Picture 1)
3.12 Vacuum breaker(s) missing - All hose bibbs (Picture 1) - can compromise public water supply safety
3.15 SAFETY CONCERN - Missing a gas shut-off valve outside of the fireplace: Rear patio (Picture 1), Basement(Picture 2)
3.16 (1) For your information: Recommend installing a washer pan with a drain
3.16 (2) For your information: Recommend installing No Burst orFlood Chek washer hoses
3.16 (3) For your information: Recommend installing a solid aluminum dryer vent instead of the foil vent (Picture 1)
CliEnlighten Home Inspections, LLC
Page 9 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
10/67
4(A) . ELECTRIC - GARAGE/EXTERIOR
Recommended that a licensed electrician perform all electrical repairs noted in this section.
Styles & Materials
SYSTEM ACCESS:Typical
SERVICE ENTRANCE CABLE:TYPE: AluminumSERVICE: Underground
AMPERAGE: 200VOLTAGE: 120/240PHASE: SingleMETER: Outside
PANEL:TYPE: Circuit breakersPANEL: Partially labeledEXPANSION ROOM: NoneSYSTEM: TroughLOCATION: Garage
PANEL COVER CAPACITY:AMPERAGE: 200
GROUNDING:Concealed
MAJOR CIRCUITS:AluminumCopperNon metallic (NM)
Armored cable (AC)
GENERAL CIRCUITS:Copper
Armored cable (AC)
RECEPTACLES:DISTRIBUTION: TypicalTYPE: 3 prong
GFCI LOCATION(S):BathExteriorKitchenRECOMMENDED: add at all wet locations
OTHER FEATURES:FIXTURES: ClosetFIXTURES: ExteriorFIXTURES: RecessedCOMPONENT: Low voltage lighting
IN NI MA m RR FYI
4.0.A ELECTRIC PANEL
4.1.A SUB PANEL
4.2.A CIRCUIT BREAKERS
4.3.A CIRCUITS/CABLES
4.4.A SERVICE ENTRY CABLE (SEC)
4.5.A METER/METER BASE
4.6.A GROUND
4.7.A RECEPTACLES
4.8.A INSTALLATION/OPERATION OF GFCI (GROUND FAULT CIRCUIT INTERRUPTER(S)
4.9.A SWITCHES/DIMMERS
4.10.A JUNCTION/WORK BOXES
4.11.A LIGHT FIXTURES
4.12.A CEILING FAN(S)
IN NI MA m RR FYI
IN= Inspected - OK at inspection, NI= Not Inspected, MA= Major problem, m= Minor problem, RR= Repair or Replace, FYI= For Your Information
Comments:
4.0.A Improper cover screws: Electric panel (Picture 1) - pointed screws should never be used to secure the panelcover
4.2.A SAFETY CONCERN - Overfused circuit(s): Electric panel (Picture 1)
CliEnlighten Home Inspections, LLC
Page 10 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
11/67
4.3.A (1) Missing conduit: Rear patio lighting cables (Picture 1)
4.3.A (2) Unprotected connections: Backyard (Picture 2) - all connections should be made in a covered junctionbox
4.3.A (3) Improper connections: Electric panel buss neutrals (Picture 1) - there should be no more than one neutralper lug.
4.7.A Wall plate(s) missing: Garage (Picture 1)
4.8.A SAFETY CONCERN - Missing GFCI receptacle(s): Multiple exterior receptacles (Pictures 1-6)
4.10.A Missing cover plate(s): Garage junction box (Picture 1), Front door (Picture 2)
4.11.A Missing/burned bulb(s): Rear patio ceiling fan (Picture 1), Garage (Picture 2), Front door (Picture 3), Left
side (Picture 4)
4.12.A Unbalanced ceiling fan: Rear patio (Picture 1)
CliEnlighten Home Inspections, LLC
Page 11 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
12/67
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
13/67
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
14/67
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
15/67
5(B) . HVAC - BASEMENT
Recommended that a licensed HVAC technician perform all HVAC repairs noted in this section.
Styles & Materials
EQUIPMENT LOCATION:Utility room
HEATING SYSTEM AGE:10 years
HEATING - FUEL TYPE:Gas with electronic ignition
HEATING CAPACITY:245000 BTUs
COMBUSTION GAS VENT/FLUE:TYPE: Metal
AIR CONDITIONING:NOT TESTED: Temperature below 60
degrees within the last 24 hoursRETROFITTED: Separate from heatingsystemTYPE: Electric CompressorCAPACITY: 2.5 tons
CONDENSER AGE:2 years
THERMOSTAT(S):ElectronicSingle - centralCAUTION: Multiple systems -simultaneous heat and AC operationpossible
DUCT SYSTEM:Metal
IN NI MA m RR FYI
5.0.B COMBUSTION AIR 5.1.B FLUE/COMBUSTION GAS VENT
5.2.B AIR HANDLER
5.3.B AIR CONDITIONER
5.4.B FILTER
5.5.B THERMOSTAT(S)
5.6.B AUTOMATIC SAFETY CONTROLS
5.7.B CONDENSATE PUMP
5.8.B CONDENSATE DRAIN LINE(S)
5.9.B DUCTWORK/PLENUM
5.10.B AIR REGISTERS
5.11.B REFRIGERANT LINES
5.12.B BOILER
5.13.B VALVE(S)
5.14.B BOILER PIPING
5.15.B PRESSURE RELIEF VALVE
5.16.B RADIATORS
5.17.B FOR YOUR INFORMATION
IN NI MA m RR FYI
IN= Inspected - OK at inspection, NI= Not Inspected, MA= Major problem, m= Minor problem, RR= Repair or Replace, FYI= For Your Information
Comments:
5.0.B Inadequate combustion air: Utility room (Picture 1) - recommend adding a louvered door
CliEnlighten Home Inspections, LLC
Page 15 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
16/67
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
17/67
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
18/67
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
19/67
7(A) . KITCHEN - BASEMENT
Recommended that a licensed general contractor perform all repairs noted in this section.
Styles & Materials
SYSTEM ACCESS:Typical
RANGE:FUEL: ElectricAGE: 20-25 yrsCONDITION: GoodREPLACEMENT PROBABILITY:Moderate (average life span = 15-20 yrs$650+)
DISPOSER:AGE: 10-15 yrsCONDITION: PoorREPLACEMENT PROBABILITY: High(average life span = 5-12 yrs)
OTHER FEATURE(S):External discharge fan
IN NI MA m RR FYI
7.0.A RANGE
7.1.A DISPOSER
7.2.A SINK
7.3.A COUNTERTOPS/CABINETS
7.4.A DRAWERS/DOORS
IN NI MA m RR FYI
IN= Inspected - OK at inspection, NI= Not Inspected, MA= Major problem, m= Minor problem, RR= Repair or Replace, FYI= For Your Information
Comments:
7.0.A (1) Inoperative oven light: Range (Picture 1)
7.0.A (2) SAFETY CONCERN - Anti-tip bracket not installed: Range (Picture 2)
7.1.A Seized: Basement kitchen sink disposer (Picture 1)
7.4.A Missing hardware: Basement kitchen cabinet doors and drawers (Picture 1)
CliEnlighten Home Inspections, LLC
Page 19 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
20/67
7(B) . KITCHEN - MAIN LEVEL
Recommended that a licensed general contractor perform all repairs noted in this section.
Styles & Materials
SYSTEM ACCESS:Typical
RANGE:AGE: 10-15 yrsCONDITION: GoodREPLACEMENT PROBABILITY:Moderate (average life span = 15-20 yrs$650+)FEATURE: Convection ovenFEATURE: Self cleaning oven
MICROWAVE:AGE: 1-5 yrsCONDITION: GoodREPLACEMENT PROBABILITY: Low(average life span = 5-10 yrs)
DISHWASHER:AGE: 10-15 yrsCONDITION: GoodREPLACEMENT PROBABILITY: High(average life span = 5-12 yrs)
REFRIGERATOR:AGE: 10-15 yrsCONDITION: GoodREPLACEMENT PROBABILITY: Low(average life span = 15-20 yrs)FEATURE: Ice makerFEATURE: Ice dispenserFEATURE: Water dispenser
DISPOSER:AGE: 1-5 yrsCONDITION: GoodREPLACEMENT PROBABILITY: Low(average life span = 5-12 yrs)
OTHER FEATURE(S):Recirculating fan
IN NI MA m RR FYI
7.0.B RANGE
7.1.B RECIRCULATING RANGE HOOD
7.2.B REFRIGERATOR
7.3.B DISHWASHER
7.4.B DISPOSER
7.5.B MICROWAVE
7.6.B SINK
7.7.B COUNTERTOPS/CABINETS
7.8.B DRAWERS/DOORS
IN NI MA m RR FYI
IN= Inspected - OK at inspection, NI= Not Inspected, MA= Major problem, m= Minor problem, RR= Repair or Replace, FYI= For Your Information
Comments:
7.2.B Inoperative: Main level kitchen refrigerator ice maker (Picture 1) and water dispenser (Picture 2) - water linedoes not appear to be hooked up
7.3.B (1) Loose: Dishwasher (Picture 1) - recommend securing to the countertop or cabinet
7.3.B (2) Continues to cycle at the one minute point and does not automatically shut off: Dishwasher (Picture 2)
CliEnlighten Home Inspections, LLC
Page 20 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
21/67
Minor Discovery Summary
Enlighten Home Inspections, LLC
39 Benton CourtSterling, VA 20165
[email protected](301) 204-2825
Customer
Sample Client
AddressSample Street
Sample Report VA
The following items or discoveries indicate that these system(s) or component(s) do not function as intended, adverselyaffect the habitability of the dwelling, appear to warrant further investigation by a specialist, or require subsequentobservation. Generally, this summary includes items that constitute "minor" problems or concerns. A minor problem orconcern is an item or discovery that would cost less than $500.00 to repair or replace. This summary shall not containrecommendations for routine upkeep of a system or component to keep it in proper functioning condition orrecommendations to upgrade or enhance the function, efficiency, or safety of the home. This Summary is not the entirereport. The complete report may include additional information of concern to the customer. It is recommended that the
customer read the complete report.
1. STRUCTURE
1.5 STRUCTURAL STEEL
Minor problem, Repair or Replace
Rusted lintels: Multiple windows/doors (Pictures 1, 2) - keep lintels scraped and painted to prevent expansionfrom rusting
CliEnlighten Home Inspections, LLC
Page 21 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
22/67
1. STRUCTURE
1.5 Picture 1 1.5 Picture 2
2. EXTERIOR2.1 ROOF DRAINAGE
Minor problem, Repair or Replace
Improper drainage/damaged underground drain: Downspouts (Picture 1) - recommend extending downspouts aminimum of 8-10 feet away from the foundation walls, further if possible. Use smooth wall pipe for extensions
2.1 Picture 1
2.3 SIDING
Minor problem, Repair or Replace
Seal siding at penetration points: Multiple areas (Pictures 1, 2) - recommend sealing all siding penetrations withduct seal
CliEnlighten Home Inspections, LLC
Page 22 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
23/67
2. EXTERIOR
2.3 Picture 1 2.3 Picture 2
2.5 MASONRY
Minor problem, Repair or Replace
Eroded/cracked/missing mortar: Multiple areas (Pictures 1-16) - point up
2.5 Picture 1 2.5 Picture 2
2.5 Picture 3 2.5 Picture 4
CliEnlighten Home Inspections, LLC
Page 23 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
24/67
2. EXTERIOR
2.5 Picture 5 2.5 Picture 6
2.5 Picture 7 2.5 Picture 8
2.5 Picture 9 2.5 Picture 10
CliEnlighten Home Inspections, LLC
Page 24 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
25/67
2. EXTERIOR
2.5 Picture 11 2.5 Picture 12
2.5 Picture 13 2.5 Picture 14
2.5 Picture 15 2.5 Picture 16
2.6 CHIMNEY(S)
Minor problem, Repair or Replace
(1) Missing flue cap and screen: Left chimney (Picture 1), Rear patio fireplace (Picture 2)
CliEnlighten Home Inspections, LLC
Page 25 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
26/67
2. EXTERIOR
2.6 Picture 1 2.6 Picture 2
(2) Cracked crown: Right chimney (Picture 3)
2.6 Picture 3
2.15 EXTERIOR DRAINAGE
Minor problem, Repair or Replace
Ponding/wet areas: Front (Picture 1) - maintain a positive flow of surface water away from foundation walls
2.15 Picture 1
CliEnlighten Home Inspections, LLC
Page 26 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
27/67
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
28/67
3. PLUMBING
3.2 Picture 3
(3) Clogged/slow drain: Jack and Jill bathroom bathtub (Picture 4), Upper level bathroom sink (Picture 5), Upperlevel bathroom bathtub (Picture 6)
3.2 Picture 4 3.2 Picture 5
3.2 Picture 6
3.3 FAUCET(S)
Minor problem, Repair or Replace
CliEnlighten Home Inspections, LLC
Page 28 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
29/67
3. PLUMBING
Faucet leaks: Jack and Jill bathroom shower head (Picture 1), Upper level bathroom shower head (Picture 2)
3.3 Picture 1 3.3 Picture 2
3.4 VALVE(S)
Minor problem, Repair or Replace
(1) Corroded valve(s): Utility room washer cold water line (Picture 1), Main level kitchen sink ice maker shut-off
(Picture 2)
3.4 Picture 1 3.4 Picture 2
(2) Valves leak: Basement bathroom shower (Picture 3), Entryway bathroom sink cold water handle (Picture 4),
Jack and Jill bathroom toilet (Picture 5)
CliEnlighten Home Inspections, LLC
Page 29 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
30/67
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
31/67
3. PLUMBING
3.5 Picture 1
3.7 BATHROOM TILE/WALL PROTECTION
Minor problem, Repair or Replace
(1) Missing/cracked caulk: Bathtub(s)/shower(s) at the tile and floor (Picture 1)
3.7 Picture 1
(2) Cracked tiles: Basement bathroom (Pictures 2, 3)
3.7 Picture 2 3.7 Picture 3
CliEnlighten Home Inspections, LLC
Page 31 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
32/67
3. PLUMBING
(3) Cracked grout: Jack and Jill bathroom bathtub tiles (Picture 4)
3.7 Picture 4
3.12 HOSE BIBB(S)
Minor problem, Repair or Replace
Vacuum breaker(s) missing - All hose bibbs (Picture 1) - can compromise public water supply safety
3.12 Picture 1
4(A). ELECTRIC - GARAGE/EXTERIOR
4.0.A ELECTRIC PANEL
Minor problem, Repair or Replace
Improper cover screws: Electric panel (Picture 1) - pointed screws should never be used to secure the panelcover
CliEnlighten Home Inspections, LLC
Page 32 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
33/67
4(A). ELECTRIC - GARAGE/EXTERIOR
4.0.A Picture 1
4.3.A CIRCUITS/CABLES
Minor problem, Repair or Replace
(1) Missing conduit: Rear patio lighting cables (Picture 1)
4.3.A Picture 1
(2) Unprotected connections: Backyard (Picture 2) - all connections should be made in a covered junction box
4.3.A Picture 2
CliEnlighten Home Inspections, LLC
Page 33 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
34/67
4(A). ELECTRIC - GARAGE/EXTERIOR
(3) Improper connections: Electric panel buss neutrals (Picture 1) - there should be no more than one neutral perlug.
4.3.A Picture 3
4.7.A RECEPTACLES
Minor problem, Repair or Replace
Wall plate(s) missing: Garage (Picture 1)
4.7.A Picture 1
4.10.A JUNCTION/WORK BOXES
Minor problem, Repair or Replace
Missing cover plate(s): Garage junction box (Picture 1), Front door (Picture 2)
CliEnlighten Home Inspections, LLC
Page 34 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
35/67
4(A). ELECTRIC - GARAGE/EXTERIOR
4.10.A Picture 1 4.10.A Picture 2
4.11.A LIGHT FIXTURES
Minor problem, Repair or Replace
Missing/burned bulb(s): Rear patio ceiling fan (Picture 1), Garage (Picture 2), Front door (Picture 3), Left side(Picture 4)
4.11.A Picture 1 4.11.A Picture 2
4.11.A Picture 3 4.11.A Picture 4
CliEnlighten Home Inspections, LLC
Page 35 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
36/67
4(A). ELECTRIC - GARAGE/EXTERIOR
4.12.A CEILING FAN(S)
Minor problem, Repair or Replace
Unbalanced ceiling fan: Rear patio (Picture 1)
4.12.A Picture 1
4(B). ELECTRIC - UTILITY ROOM/INTERIOR
4.1.B SUB PANEL
Minor problem, Repair or Replace
(1) Improperly terminated cables: Utility room sub panel (Picture 1)
4.1.B Picture 1
(2) Loose panel cover: Utility room sub panel (Picture 2)
CliEnlighten Home Inspections, LLC
Page 36 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
37/67
4(B). ELECTRIC - UTILITY ROOM/INTERIOR
4.1.B Picture 2
4.3.B CIRCUITS/CABLES
Minor problem, Repair or Replace
Missing wire clamp: Basement kitchen sink disposer feed wire (Picture 1)
4.3.B Picture 1
4.7.B RECEPTACLES
Minor problem, Repair or Replace
(1) Wall plate(s) missing: Basement bathroom (Picture 1). Main level middle bedroom closet (Pictures 2, 3), Masterbedroom (Picture 4)
CliEnlighten Home Inspections, LLC
Page 37 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
38/67
4(B). ELECTRIC - UTILITY ROOM/INTERIOR
4.7.B Picture 1 4.7.B Picture 2
4.7.B Picture 3 4.7.B Picture 4
(2) Reversed polarity: Basement bathroom (Picture 5), Basement rear right room (Picture 6), Main level kitchen
(Picture 7), Main level office (Picture 8), Main level hall (Picture 9), Attic front bedroom (Picture 10)
CliEnlighten Home Inspections, LLC
Page 38 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
39/67
4(B). ELECTRIC - UTILITY ROOM/INTERIOR
4.7.B Picture 5 4.7.B Picture 6
4.7.B Picture 7 4.7.B Picture 8
4.7.B Picture 9 4.7.B Picture 10
(3) Ungrounded electrical receptacles: Basement rear right room (Pictures 11, 12)
CliEnlighten Home Inspections, LLC
Page 39 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
40/67
4(B). ELECTRIC - UTILITY ROOM/INTERIOR
4.7.B Picture 11 4.7.B Picture 12
(4) Loose receptacle(s): Main level kitchen (Picture 13)
4.7.B Picture 13
4.9.B SWITCHES/DIMMERS
Minor problem, Repair or Replace
(1) Wall plate(s) missing: Utility room (Picture 1)
4.9.B Picture 1
CliEnlighten Home Inspections, LLC
Page 40 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
41/67
4(B). ELECTRIC - UTILITY ROOM/INTERIOR
(2) Defective dimmer: Basement safe room (Pictures 2, 3)
4.9.B Picture 2 4.9.B Picture 3
4.11.B LIGHT FIXTURES
Minor problem, Repair or Replace
(1) Unprotected closet fixture(s): Multiple closets (Picture 1) - recommend installing a fixture with a protectiveglobe
4.11.B Picture 1
(2) Missing/burned bulb(s): Main level middle bedroom closet (Picture 2), Main level hall ceiling fixtures (Picture3)
CliEnlighten Home Inspections, LLC
Page 41 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
42/67
4(B). ELECTRIC - UTILITY ROOM/INTERIOR
4.11.B Picture 2 4.11.B Picture 3
4.12.B CEILING FAN(S)
Minor problem, Repair or Replace
Inadequate clearance: Basement rear right room ceiling fan (Picture 1) - blades should be a minimum of 7' fromthe ground
4.12.B Picture 1
5(A). HVAC - UPPER LEVEL
5.5.A CONDENSATE DRAIN LINE(S)
Minor problem, Repair or Replace
Missing cap: Attic AC condensate drain line (Picture 1)
CliEnlighten Home Inspections, LLC
Page 42 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
43/67
5(A). HVAC - UPPER LEVEL
5.5.A Picture 1
5(B). HVAC - BASEMENT5.0.B COMBUSTION AIR
Minor problem, Repair or Replace
Inadequate combustion air: Utility room (Picture 1) - recommend adding a louvered door
5.0.B Picture 1
5.4.B FILTER
Minor problem, Repair or Replace
Dirty reusable HVAC filter: Utility room in the AC return plenum (Picture 1) - clean
CliEnlighten Home Inspections, LLC
Page 43 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
44/67
5(B). HVAC - BASEMENT
5.4.B Picture 1
5.8.B CONDENSATE DRAIN LINE(S)
Minor problem, Repair or Replace
Missing cap: AC condensate drain line (Picture 1)
5.8.B Picture 1
5.9.B DUCTWORK/PLENUM
Minor problem, Repair or Replace
Missing duct insulation: Garage (Picture 1)
CliEnlighten Home Inspections, LLC
Page 44 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
45/67
5(B). HVAC - BASEMENT
5.9.B Picture 1
6. INTERIOR6.4 DOORS (REPRESENTATIVE NUMBER)
Minor problem, Repair or Replace
Doors do not latch/doors rub/bind: Multiple doors (Pictures 1-3) - adjust hardware
CliEnlighten Home Inspections, LLC
Page 45 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
46/67
6. INTERIOR
6.4 Picture 1 6.4 Picture 2
6.4 Picture 3
6.9 ATTIC MOISTURE
Minor problem, Repair or Replace
Moisture stains: Attic (Pictures 1, 2), monitor
6.9 Picture 1 6.9 Picture 2
6.13 FIRE SEPARATION
CliEnlighten Home Inspections, LLC
Page 46 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
47/67
6. INTERIOR
Minor problem, Repair or Replace
Missing fire stop: Garage ceiling (Pictures 1, 2)
6.13 Picture 1 6.13 Picture 2
7(A). KITCHEN - BASEMENT
7.0.A RANGE
Major problem, Minor problem, Repair or Replace
(1) Inoperative oven light: Range (Picture 1)
7.0.A Picture 1
7.1.A DISPOSER
Minor problem, Repair or Replace
Seized: Basement kitchen sink disposer (Picture 1)
CliEnlighten Home Inspections, LLC
Page 47 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
48/67
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
49/67
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
50/67
7(B). KITCHEN - MAIN LEVEL
Prepared Using HomeGauge http://www.HomeGauge.com : Licensed To Isaac Kieffer
CliEnlighten Home Inspections, LLC
Page 50 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
51/67
MAJOR Discovery Summary
Enlighten Home Inspections, LLC
39 Benton CourtSterling, VA 20165
[email protected](301) 204-2825
Customer
Sample Client
AddressSample Street
Sample Report VA
The following items or discoveries indicate that these system(s) or component(s) do not function as intended, adverselyaffect the habitability of the dwelling, appear to warrant further investigation by a specialist, or require subsequentobservation. This summary includes those items that constitute "MAJOR" problems or concerns. A major problem orconcern is any item or discovery that would cost more than $500.00 to repair or replace. This summary shall not containrecommendations for routine upkeep of a system or component to keep it in proper functioning condition orrecommendations to upgrade or enhance the function, efficiency, or safety of the home. This Summary is not the entirereport. The complete report may include additional information of concern to the customer. It is recommended that the
customer read the complete report.
1. STRUCTURE
1.0 FOUNDATION WALLS
Major problem, Repair or Replace
Foundation settlement crack(s): Garage (Picture 1) - recommend contacting a licensed structural engineer tofurther evaluate
CliEnlighten Home Inspections, LLC
Page 51 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
52/67
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
53/67
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
54/67
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
55/67
2. EXTERIOR
(2) SAFETY CONCERN - Loose hand/safety rail: Left side stairs (Picture 4)
2.8 Picture 4
2.14 LANDSCAPING
Major problem, Repair or Replace
MONETARY CONCERN - Large tree(s) overhanging: Multiple trees (Picture 1) - keep branches trimmed away
from roof and house
2.14 Picture 1
2.17 RETAINING WALL(S)
Major problem, Repair or Replace
SAFETY CONCERN - Retaining walls bowed/pulling away from the house: Back left side (Pictures 1, 2) - monitor
CliEnlighten Home Inspections, LLC
Page 55 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
56/67
2. EXTERIOR
2.17 Picture 1 2.17 Picture 2
3. PLUMBING
3.15 GAS PIPE
Major problem, Repair or Replace
SAFETY CONCERN - Missing a gas shut-off valve outside of the fireplace: Rear patio (Picture 1), Basement(Picture 2)
3.15 Picture 1 3.15 Picture 2
4(A). ELECTRIC - GARAGE/EXTERIOR
4.2.A CIRCUIT BREAKERS
Major problem, Repair or Replace
SAFETY CONCERN - Overfused circuit(s): Electric panel (Picture 1)
CliEnlighten Home Inspections, LLC
Page 56 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
57/67
4(A). ELECTRIC - GARAGE/EXTERIOR
4.2.A Picture 1
4.8.A INSTALLATION/OPERATION OF GFCI (GROUND FAULT CIRCUIT INTERRUPTER(S)
Major problem, Repair or Replace
SAFETY CONCERN - Missing GFCI receptacle(s): Multiple exterior receptacles (Pictures 1-6)
CliEnlighten Home Inspections, LLC
Page 57 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
58/67
4(A). ELECTRIC - GARAGE/EXTERIOR
4.8.A Picture 1 4.8.A Picture 2
4.8.A Picture 3 4.8.A Picture 4
4.8.A Picture 5 4.8.A Picture 6
4(B). ELECTRIC - UTILITY ROOM/INTERIOR
4.2.B CIRCUIT BREAKERS
Major problem, Repair or Replace
CliEnlighten Home Inspections, LLC
Page 58 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
59/67
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
60/67
4(B). ELECTRIC - UTILITY ROOM/INTERIOR
4.8.B Picture 1 4.8.B Picture 2
4.8.B Picture 3 4.8.B Picture 4
CliEnlighten Home Inspections, LLC
Page 60 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
61/67
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
62/67
5(B). HVAC - BASEMENT
5.1.B Picture 1 5.1.B Picture 2
6. INTERIOR6.10 STEPS, STAIRWAYS, BALCONIES AND RAILINGS
Major problem, Repair or Replace
(1) SAFETY CONCERN - Missing hand rail: Entryway stairs (Picture 1) - handrails should be continuous alongthe entire length of the stairs
6.10 Picture 1
(2) SAFETY CONCERN - Safety rails do not meet current child safety standards: Upper level stairs (Picture 2) -
balusters should be spaced a maximum of 4" apart
CliEnlighten Home Inspections, LLC
Page 62 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
63/67
6. INTERIOR
6.10 Picture 2
6.11 SMOKE DETECTORS
Major problem, Repair or Replace
SAFETY CONCERN - Inoperative smoke detector(s): Main level hall ceiling (Picture 1) - highly recommend onesmoke alarm in the general living space on each level, and one in each bedroom. Any smoke alarm ten or more
years old needs to be replaced. If the age cannot be determined, it is best to replace the alarm(s)
6.11 Picture 1
7(A). KITCHEN - BASEMENT
7.0.A RANGEMajor problem, Minor problem, Repair or Replace
(2) SAFETY CONCERN - Anti-tip bracket not installed: Range (Picture 2)
CliEnlighten Home Inspections, LLC
Page 63 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
64/67
7(A). KITCHEN - BASEMENT
7.0.A Picture 2
Prepared Using HomeGauge http://www.HomeGauge.com : Licensed To Isaac Kieffer
CliEnlighten Home Inspections, LLC
Page 64 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
65/67
General Summary
Enlighten Home Inspections, LLC
39 Benton CourtSterling, VA 20165
[email protected](301) 204-2825
Customer
Sample Client
AddressSample Street
Sample Report VA
1. STRUCTURE
1.7 FOR YOUR INFORMATION
For Your Information
For your information: Recommend installing a dehumidifier in the basement
2. EXTERIOR
2.20 FOR YOUR INFORMATION
For Your Information
For your information: Clean debris from window well(s) to allow water to drain quickly (Picture 1)
2.20 Picture 1
CliEnlighten Home Inspections, LLC
Page 65 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
66/67
2. EXTERIOR
3. PLUMBING
3.9 PIPES AND FITTINGS
For Your Information
For your information: Freeze vulnerable pipes - Rear hose bibb (Picture 1)
3.9 Picture 1
3.16 FOR YOUR INFORMATION
For Your Information
(1) For your information: Recommend installing a washer pan with a drain
(2) For your information: Recommend installing No Burst orFlood Chek washer hoses
(3) For your information: Recommend installing a solid aluminum dryer vent instead of the foil vent (Picture 1)
3.16 Picture 1
5(A). HVAC - UPPER LEVEL
5.10.A FOR YOUR INFORMATION
For Your Information
CliEnlighten Home Inspections, LLC
Page 66 of Sample Street
-
7/30/2019 Enlighten Home Inspections, LLC - Sample Website Report
67/67
5(A). HVAC - UPPER LEVEL
For your information: Recommend contacting a licensed AC technician to service the unit once a year in the
spring
5(B). HVAC - BASEMENT
5.17.B FOR YOUR INFORMATION
For Your Information(1) For your information: Recommend contacting a licensed HVAC technician to service the heating and A/Cunits twice a year
(2) For your information: Recommend cleaning the reusable HVAC filter every 30 days of operational use
6. INTERIOR
6.14 LEAD PAINT
For Your Information
For your information: Any structure built prior to 1978 likely contains lead based paint
6.15 FOR YOUR INFORMATIONFor Your Information
(1) For your information: Recommend contacting a licensed chimney sweep to clean and inspect the flues
(2) For your information: Recommend installing at least one carbon monoxide detector on every level and withinten feet of every bedroom
Prepared Using HomeGauge http://www.HomeGauge.com : Licensed To Isaac Kieffer
CliEnlighten Home Inspections, LLC