For the Attention of: Mrs. Phoebe Dillane
Environmental Officer.
Bord na Móna Resource Recovery.,
Bord na Móna Offices,
Main Street Newbridge,
Co. Kildare.
Site Work Completed by: Ms. Kate Tynan
Sampling Date: 19/11/15 (SW)
No Trade effluent reported for this period
Report Prepared by: Ms. Kate Tynan
Environmental Scientist
Report Reviewed by: Mr. Peter Coogan
Environmental Team Leader
Report Ref No: ECS5125-SW/TE
Monitoring Period: Q4 2015
Report Date: 26th January 2016
This report shall not be reproduced except in full, without the approval of Bord na Móna Environmental. All queries concerning the report or its
contents should be forwarded to the Monitoring Team Leader.
_______________________________________________________________________________________________________
ENVIRONMENTAL MONITORING AT AES, TULLAMORE,
CO. OFFALY;
SURFACE-WATER/ TRADE EFFLUENT (4 OF 4)
IN ACCORDANCE WITH WASTE LICENCE REGISTER
NO.
W0104-03
For
insp
ectio
n pur
pose
s only
.
Conse
nt of
copy
right
owne
r req
uired
for a
ny ot
her u
se.
EPA Export 14-04-2016:01:49:28
AES Tullamore (W0104-03) Report No. ECS5125
December 2015 Page 2
EXECUTIVE SUMMARY
In accordance with Waste Licence Register No. W0104-03, Advanced Environmental Solutions Ltd.
(AES) is required to carry out a quarterly assessment of Surface Waters Discharge and Trade Effluent
at its site at Cappancur, Tullamore, Co. Offaly.
The Quarter 4 surface water monitoring was carried out by an Environmental Scientist from Bord na
Móna Environmental on the 19th of November 2015.
Trade Effluent (TE)
All trade effluent generated onsite is sent by tanker to the local authority wastewater treatment plant. If
the effluent is tankered off-site a sample taken and analysed. As no effluent was tankered off-site during
this period, no analysis was completed.
Surface Water
The AES site was visited by Bord na Mona Environmental on a number of dates during Qtr4 to obtain
a discharge sample at SW-1.On each occasion the discharge location was flooded. As a result a
representative sample of the sites discharge could not be obtained for this quarter. The site was also
visited by Mr. Ross O’Dwyer (EPA) on the 2nd of December to carry out surface water sampling, on this
occasion the area was also classified as flooded.
Ammonia concentrations have increased since last monitored in quarter 3 (0.42mg/l to 0.55mg/),
however it is still within the agreed trigger action limit of 0.9mg/l. COD (58mg/l) exceeded the trigger
warning limit (40mg/l) and the trigger action limit (50mg/l).
All remaining results are below both the Warning & Action Trigger Limits as agreed with the Agency and
are within line with previously detected values.
This report is certified as accurate and representative of the sampling and associated analysis carried
out.
Respectively Submitted,
__________________________ _________________________________
Ms. Kate Tynan Mr. Peter Coogan
Environmental Scientist Environmental Team Leader
For
insp
ectio
n pur
pose
s only
.
Conse
nt of
copy
right
owne
r req
uired
for a
ny ot
her u
se.
EPA Export 14-04-2016:01:49:28
AES Tullamore (W0104-03) Report No. ECS5125
1.0 INTRODUCTION
In accordance with Waste Licence Register No. W0104-03, Advanced Environmental Solutions
Ltd. (AES) is required to carry out an assessment of the Trade Effluent and Surface Water
quality at its site at Cappincur, Tullamore, Co. Offaly on a quarterly basis.
Bord na Móna Environmental was commissioned to perform the sampling and analysis.
Samples were taken from SW1 on the 19th November and returned to the laboratory for
analysis.
This report details the sampling methodologies and procedures followed and describes the
findings of the sampling and analysis.
2.0 METHODOLGY
2.1 Monitoring Locations
The sampling locations are described in Table 2.1 below and marked on the map contained in
Appendix 1.
TABLE 1: LOCATION OF SURFACE WATER SAMPLING STATIONS
Map Reference No. Location
SW-1
South-west perimeter of site. Drainage ditch (discharge pipe) – Tributary of
Tullamore River
TE Adjacent to Eastern boundary of main waste reception shed
2.2 Sampling
Grab samples were extracted in accordance with the following standards;
TABLE 2: SAMPLING PROCEDURE AND GUIDANCE
ISO Standard Description
ISO 5667-1-2006 Guidance on the design of sampling programmes and sampling techniques
ISO 5667-3-2012 Guidance on sample preservation and handling
ISO 5667-14-2014 Guidance on quality assurance of environmental sampling & handling
ISO 5667-6-2012 Guidance on sampling rivers & streams
Sampling was conducted in strict accordance with Bord na Móna Environmental recognised
Standard Operations Procedures (SOP) TS-W-02. All samples were returned to the laboratory,
and stored between 1-8°C. Details of the laboratory accreditation, methods and quality
standards are provided in Appendix 2.
For
insp
ectio
n pur
pose
s only
.
Conse
nt of
copy
right
owne
r req
uired
for a
ny ot
her u
se.
EPA Export 14-04-2016:01:49:28
AES Tullamore (W0104-03) Report No. ECS5125
December 2015 Page 4
3.0 RESULTS
3.1 Tankered Effluent Results
During Quarter 4 the site did not send any trade effluent offsite for treatment at a waste water
treatment facility therefore no sample of trade effluent was taken.
3.2 Storm Water Results
TABLE 3: RESULTS OF CHEMICAL ANALYSIS OF SURFACE WATER SAMPLE
Parameter Units SW-1
Discharge
Limits Note 1
Trigger
Warning
Limits
Trigger
Action
Limits
Field Readings
pH pH units 7.17 >6.5 - <9.5 >6.5 - <9.0
Temperature °C 9.5 - -
Conductivity µs/cm 654 900 1000
Dissolved Oxygen mg/L 6.60 - -
% 58.3 - -
On-Site Visual Inspection
- Light Yellow, No
Suspended Solids No abnormal
changes No abnormal
changes Odour - None
Laboratory Analysis
BOD Note 2 mg/l <2 2.6 3.72
COD Note 2 mg/l 58 40 50
Suspended Solids Note 2 mg/l <5 25 35
Ammonia as N Note 2 mg/l 0.55 0.14 0.9
Chloride Note 2 mg/l 28 40 50
**DRO mg/l <0.01 – –
**Mineral Oil mg/l <0.01 0.01 0.01
Notes: ** Subcontracted Analysis
Note 1: Action and warning limits as agreed with the agency.
< Less than laboratory limit of detection
Note 2: See Appendix 2 for Laboratory Test Methods / Accreditation.
For
insp
ectio
n pur
pose
s only
.
Conse
nt of
copy
right
owne
r req
uired
for a
ny ot
her u
se.
EPA Export 14-04-2016:01:49:28
AES Tullamore (W0104-03) Report No. ECS5125
December 2015 Page 5
4.0 DISCUSSION & INTREPERTATION
Surface Water
The AES site was visited by Bord na Mona Environmental on a number of dates during Qtr4 to
obtain a discharge sample at SW-1.On each occasion the discharge location was flooded. As
a result a representative sample of the sites discharge could not be obtained for this quarter.
The site was also visited by Mr. Ross O’Dwyer (EPA) on the 2nd of December to carry out
surface water sampling, on this occasion the area was also classified as flooded.
For comparison and discussion purposes results are compared to their respective Trigger Limits
and the previous monitoring event (see Report Ref: ECS5125 – Qtr 3 2015).
Ammonia concentrations (0.55mg/l) were elevated above the agreed Trigger Warning Limit
(0.14mg/l) on this sampling occasion however the result was below the Trigger Action Limit of
0.9mg/l. The ammonia concentration have increased since the previous monitoring event in
July. COD concentrations (58mg/l) were elevated above the agreed Trigger Warning Limit
(40mg/l) and Trigger Action Limit (50mg/l).
The results of all remaining parameters were found to be below both the Trigger Warning & Trigger
Action Limits as agreed with the Agency. All remaining results when compared to Quarter 3 were
similar with a few slight variations.
.
For
insp
ectio
n pur
pose
s only
.
Conse
nt of
copy
right
owne
r req
uired
for a
ny ot
her u
se.
EPA Export 14-04-2016:01:49:28
AES Tullamore (W0104-03) Report No. ECS5125
December 2015 Page 6
APPENDIX I
Monitoring Locations
For
insp
ectio
n pur
pose
s only
.
Conse
nt of
copy
right
owne
r req
uired
for a
ny ot
her u
se.
EPA Export 14-04-2016:01:49:28
TE
For
insp
ectio
n pur
pose
s only
.
Conse
nt of
copy
right
owne
r req
uired
for a
ny ot
her u
se.
EPA Export 14-04-2016:01:49:28
AES Tullamore (W0104-03) Report No. ECS5125
December 2015 Page 8
APPENDIX 2
Analytical Methods
Lab Accreditation
Chain of Custody
For
insp
ectio
n pur
pose
s only
.
Conse
nt of
copy
right
owne
r req
uired
for a
ny ot
her u
se.
EPA Export 14-04-2016:01:49:28
AES Tullamore (W0104-03) Report No. ECS5125
December 2015 Page 9
Analytical Methods
Analysis of water sampling was conducted in accordance with recognised standard methods as detailed
below
ANALYSIS OF SAMPLES
Parameter Limit of Detection Method Accredited
Visual Inspection - On-Site Visual Determination -
Odour - On-Site Sensory Determination -
pH (pH units) 0.1 – 14 In-Situ Calibrated pH /
Temperature Thermometer -
Conductivity (µs/cm) 0.01 μS/cm to 200.0 mS/cm
In-Situ Calibrated Conductivity
Meter
-
Temperature (oC) -10 to 110 °C In-Situ Calibrated pH /
Temperature Thermometer -
Ammonia-N (mg/l) <0.02 mg/l NH3-N G/67: Based on APHA, 2012, 22nd
Ed,4500-NH3 & Bluebook Ammonia in Waters 1981
INAB
Biochemical Oxygen Demand (BOD) (mg/l)
<2 mg/l BOD G/04: Based on APHA, 2012, 22nd
Ed, Method 5210B. INAB
Chemical Oxygen Demand(COD)(mg/l)
<10 mg/l G/03: Based on APHA 2012, 22nd
Edition, Method 5220D
INAB
Suspended Solids (mg/l)
< 5mg/l dried residue G/19: Based on APHA, 2012, 22nd
Ed, Method 2540D INAB
Chloride (mg/l) <2 mg/l Cl G/67: Based on APHA, 2012, 22nd
Ed, Method 4500-Cl INAB
Heavy Metals (µg/l) <2µg/l G112 Based on EPA Method
200.8 X
*Mineral Oils & *DROs <0.010 mg/l GC X
Notes:
INAB Accredited Test Method – INAB Registration Reference No. 083T.
X Non-INAB or UKAS Accredited Test Method
* Sub-Contracted Test – Jones Environmental, UKAS Accredited Laboratory, UK.
G/ INAB Accredited Method, Bord na Móna Environmental & Analytical Services Standard Operating
Procedures Manual
APHA- American Public Health Association, Standard Methods for the Examination of Waters and Wastewaters,
22nd Edition, 2012.
< Less than laboratory limit of detection
For
insp
ectio
n pur
pose
s only
.
Conse
nt of
copy
right
owne
r req
uired
for a
ny ot
her u
se.
EPA Export 14-04-2016:01:49:28
AES Tullamore (W0104-03) Report No. ECS5125
December 2015 Page 10
ACCREDITED QUALITY SYSTEM
INAB Accreditation
Bord na Móna Environmental analytical laboratories are accredited to ISO 17025 by the National
Accreditation Board (INAB). ISO 17025 accreditation ensures that the laboratory operates a quality
system with technically competent staff. The laboratory has accreditation since 1997 and it is the policy
of the laboratory to achieve and maintain a high standard of quality consistent with client's requirements
in all aspects of the work carried out within the laboratory.
Interlaboratory Proficiency Schemes
To ensure the accuracy of the analytical testing the laboratory participates in several external
proficiency schemes. The ongoing competence of the laboratory and its staff is assessed by
participation in various inter-laboratory proficiency testing schemes, such as LGC Aquacheck scheme
and the EPA Intercalibration programme organised for environmental laboratories throughout Ireland.
Bord na Mona Environmental Laboratory Services & Analytical Laboratory is listed on the EPA’s register
of Quality Controlled Laboratories
Control Chain of Custody
As part of the Quality System in place in Bord na Móna Environmental, measures are taken to ensure
controlled chain of custody. An outline of the chain of custody is given below.
Bord na Móna Environmental
SITE TRANSPORT LABORATORY
Sampling and packaging of
all samples were carried out
by BnM Environmental
Monitoring Team:
Transport
Document
Form
Transport to
laboratory by BnM
Environmental
Technical Team.
Sample
Reception
Form
Receiving of samples at BnM
Environmental Laboratory complex
by: Laboratory Manager
(Secure laboratory complex access
to authorised personnel only)
Kate Tynan
Storage of all samples for 1 month
period after report issue.
Supervised Disposal
CONTROLLED CHAIN OF CUSTODY
For
insp
ectio
n pur
pose
s only
.
Conse
nt of
copy
right
owne
r req
uired
for a
ny ot
her u
se.
EPA Export 14-04-2016:01:49:28
AES Tullamore (W0104-03) Report No. ECS5125
December 2015 Page 11
APPENDIX 3
Laboratory Certificate
For
insp
ectio
n pur
pose
s only
.
Conse
nt of
copy
right
owne
r req
uired
for a
ny ot
her u
se.
EPA Export 14-04-2016:01:49:28
For
insp
ectio
n pur
pose
s only
.
Conse
nt of
copy
right
owne
r req
uired
for a
ny ot
her u
se.
EPA Export 14-04-2016:01:49:28