© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 1/45 Ed. Cover: 06 CODE : IMC0181AEDG DRAFT DOCUMENT TYPE : USER MANUAL PROJECT NAME : SRAL XD / TITLE : EOW User and installation manual LCT User manual VERSION : 0 REVISION : 1 STATUS : DRAFT DATE : 2005-01-26 09:18:16 Issued by PG – MW SS. Padana Superiore km 158 20060 Cassina De’ Pecchi (MI) The reproduction, transmission or use of this document or its contents is not permitted without express written authority. Infringers will be liable for damages. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Technical modifications possible. Technical specifications and features are binding only insofar as they are specifically and expressly agreed upon in a written contract. ______________________________________________________________________________________ Siemens Mobile Communications S.p.A. AUTHOR : f.to APPROVED BY : f.to

Upload: neelan-naidu-budumuru

Post on 02-Apr-2015

161 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 1/45 Ed. Cover: 06

CODE : IMC0181AEDG

DRAFT

DOCUMENT

TYPE

: USER MANUAL

PROJECT NAME : SRAL XD /

TITLE : EOW User and installation manual

LCT User manual

VERSION : 0 REVISION : 1

STATUS : DRAFT DATE : 2005-01-26 09:18:16

Issued by PG – MW SS. Padana Superiore km 158 20060 Cassina De’ Pecchi (MI) The reproduction, transmission or use of this document or its contents is not permitted without express written authority. Infringers will be liable for damages. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Technical modifications possible. Technical specifications and features are binding only insofar as they are specifically and expressly agreed upon in a written contract. ______________________________________________________________________________________ Siemens Mobile Communications S.p.A. AUTHOR : f.to APPROVED BY : f.to

Page 2: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 2/45 Ed. Cover: 06

In addition to the authors named on the cover page the following persons have collaborated on this document : More information notes. <User defined>

CHANGE HISTORY

VER. REV. CHANGE 0 1 First Draft emission

Page 3: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 3/45 Ed. Cover: 06

1 Index 1 INDEX ....................................................................................................................................................... 3

2 ACRONYMS AND ABBREVIATIONS ................................................................................................ 5

3 INTRODUCTION TO THE EOW UNIT .............................................................................................. 6

4 MAIN FEATURES OF THE EOW UNIT............................................................................................. 6

5 GENERAL NOTES.................................................................................................................................. 6

6 CONNECTION TYPE........................................................................................................................... 10

7 SERVICE NETWORK ACCESS MODES.......................................................................................... 10

8 CALLS..................................................................................................................................................... 10 8.1 GENERAL ASPECTS ............................................................................................................................ 10 8.2 LINE ENGAGEMENT............................................................................................................................ 11 8.3 SELECTIVE CALL ............................................................................................................................... 11 8.4 OMNIBUS CALL .................................................................................................................................. 12

9 DTMF SIGNALLING CODES ............................................................................................................. 13

10 ELECTROMAGNETIC COMPATIBILITY AND SAFETY........................................................ 13 EMISSIONS .................................................................................................................................................... 13 IMMUNITY..................................................................................................................................................... 14 SAFETY ......................................................................................................................................................... 15

11 TECHNICAL FEATURES ................................................................................................................ 16 11.1 GENERAL........................................................................................................................................ 16 11.2 INTERFACES AND ELECTRICAL CHARACTERISTICS ........................................................................ 16 11.3 DTMF SIGNALLING ....................................................................................................................... 18 11.4 CONTROL TONES............................................................................................................................ 19 11.5 CARD FAIL ALARM ........................................................................................................................ 19 11.6 OPERATING VOLTAGE AND POWER CONSUMPTION........................................................................ 19

12 MECHANICAL CHARACTERISTICS AND FRONT PANEL DESCRIPTION....................... 20

13 LED TABLE........................................................................................................................................ 22

14 CONNECTIONS................................................................................................................................. 24

15 PART NUMBERING ......................................................................................................................... 27

16 V.11 POLARITY AND PHASE RELATIONSHIPS....................................................................... 28

17 LCT PROGRAMMING SOFTWARE – USER MANUAL ........................................................... 29 17.1 MAIN WINDOW .............................................................................................................................. 29 17.2 “SYSTEM INFO” WINDOW............................................................................................................. 32

Page 4: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 4/45 Ed. Cover: 06

17.3 “STATION NUMBER” WINDOW ................................................................................................. 33 17.4 ”EXT I/F LEVELS” WINDOW ....................................................................................................... 36 17.5 “SW UPGRADE” WINDOW .......................................................................................................... 38

Page 5: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 5/45 Ed. Cover: 06

2 Acronyms and abbreviationsBB BaseBand DTMF Dual Tone Multi Frequencies EOW Engineering Order Wire I/O Input / Output IDU Indoor unit LCT Local Craft Terminal LED Light Emitting Diode PDH Plesiochronous Digital Hierarchy SDH Synchronous Digital Hierarchy SLIC Subscriber Line Circuit SRAL Small Capacity Equipment SRAL XD Small Capacity Equipment SRA4 Medium Capacity Equipment SU Standard Unit

Page 6: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 6/45 Ed. Cover: 06

3 Introduction to the EOW unit The EOW unit has been designed to supply a telephone service channel to be used in networks composed by new generation SRAL XD and SRA 4 equipment. The channel availability will be realized on request in selected stations, by adding the EOW unit to the equipment rack. In a network made up completely of SRAL XD or SRA4 equipment, it will have the role of service phone channel. In existing SRAL networks, where the nodes are equipped with previous generation equipment, there are the plug-in EOW units currently available. In case of an mixed SRAL/SRAL XD network, total compatibility and interworking is assured between present and past EOW units. The new EOW unit described in this manual is also compatible with existing PDH service channels, employing E&M decadic signalling codes.

4 Main Features of the EOW unit Below are described the main features of the EOW unit:

2 x V.11 Interface (64 Kbit/s) for connection to SRAL XD and SRA 4 IDUs (User Channel). Both (1+1) e 2x(1+0) network topologies are supported.

1. Interworking with Siemens small capacity equipment (SRAL) of previous generation. 2. 2 analog interfaces, with 4 Wire+E&M signalling, to guarantee compatibilità with both versions of

EOW SRA L (612-910/21 e 612-910/22). 3. Through E&M decadic signalling, compatibility is ensured with external equipment using this kind

of interface. 4. Selective call (with inclusion function and multiple call) and omnibus call. 5. Local station number, selectable between 2 or 3 digits, and locally programmable through an RS232

interface. 6. Card Fail alarm reporting to supervisory system or radio equipment. 7. Can be used as an analog to digital converter for analog voice channel extension on V.11 channels.

It guarantees error-free data transmission for V.32 point-to-point leased line modems (up to 9600 b/s) and V.32 bis (up to 14.400 b/s).

8. Uses the same handset of the SRA L (634-901/03). 9. Mechanical structure suitable for 19” and ETSI-N3 sub-rack mounting, with 1 SU height. 10. -48V power supply. 11. EMC/Safety compliant , CE marked.

5 General notes The EOW unit allows access to the telephone service channel, both for the small capacity radio system (SRAL XD) and for the medium capacity one (SRA 4), exploiting the USER byte in the Base Band frames of PDH and SDH systems. The EOW unit interfaces the telephone handset with keypad on one side, using DTMF (Dual Tone Multi Frequency) signalling system; on the other side the interface is with above mentioned systems, through access ports with V.11 levels.

Page 7: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 7/45 Ed. Cover: 06

The unit integrates the circuits of branching, exchange, and restitution of the voice channel and E&M signalling, to guarantee full interworking with the present telephone channel of SRAL networks, as well as older PDH selective call systems. Some network topologies are shown in Figure 1. The block diagram of the EOW unit is shown in Figure 2 and includes the following devices:

Conversion and branching. conversation. DTMF and E&M signalling.

In systems with two separate multiplexing sections (1+1 and 2x(1+0) systems), the operator has access to USER byte on side 1 and side 2, without duplicating the unit. To the aim of the phone service, the equipment can always be considered in (1+1) configuration, i.e. the voice signal must be paralleled in the transmission path and mixed in the receiving path in all directions. In Figura 3 is shown the block diagram of the EOW unit.

V11 V11 TS T

S

SRAL XD/SRA4 (1+1)

SRAL XD/SRA4 (1+1)

V11

SRAL XD/SRA4 (1+1)

SRAL EOW

SRAL EOW

SRAL EOW

4 wires intra-office analog link

SRAL SRAL SRAL

T

TS

TS

SRAL EOW

4W 4W

4W

4W

4W

SRAL XD SRA4

SRAL XD SRA4 SRAL XD

SRA4

SRAL

V11

V11

V11

RADIO LINKS

Note: Audio loops must be avoided.

Figure 1 - Above: TS application in 1+1 and 2+0 SRAL XD or SRA4 networks and interworking with

SRAL EOW. Below: TS Chain Application via analog 4 wires (same site)

Page 8: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 8/45 Ed. Cover: 06

DTMF

TELEPHONE

2 Wires TIP-RING

F (RS232)

V BAT

RJ 45 RJ 45

4W +EM Analog

TS

LINE 1, V11

LINE 2, V11

TO BB CARDS # 1 & # 2

INTERFACES

1 2

Figure 2

Page 9: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 9/45 Ed. Cover: 06

Figura 3 – EOW block diagram

DC/DC Converter

Vbatt.= -48V Vout1= 3.3V

Vout2= 5V

uP 89C51RC2/RD2

series

RS232 I/F

Card FAIL Boards Controls

E&M Audio I/F

E&M Sig. I/F

Sync. Gen.& Extract.

V11 I/F 1

V11 I/F 2

Codec 1

Codec 2

Analog I/F1

Line 1

Line 2

E&M Audio I/F

E&M Sig. I/F

Analog I/F2

Mixer Audio

Rx/Tx DTMF

Tone Gen.

Controls

Controls

Controls

Controls 2W/4W Conv.

DC Bridge

Tip/Ring

Controls

Page 10: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 10/45 Ed. Cover: 06

6 Connection type The user has access to the telephone service channel through the standard telephone interface, 2 wires (TIP, RING) using the Bantam type jack socket. The EOW unit allows the following connection types for stations belonging to the service network:

Between any two stations (selective call) Between one station and all others (omnibus connection)

The two EOW extension ports (4 wire +E&M analog interfaces) will be used towards external equipment.

7 Service network access modes The access is intended to the areas relevant to multiplexing sections of the aggregate signal. The EOW unit, if free, will be automatically connected to the calling section, following the reception of a call. In case of outgoing calls, the access to the line is granted by lifting the handset and selection, if the line is in the free state.

8 Calls

8.1 General aspects The service channel employs in-band signalling, DTMF type, and E&M on analog expansion ports. It allows the following functionalities:

selective and omnibus calls on line. multiple selective call (1 added user).

The EOW unit includes the circuits necessary for generating, sending, receiving and detecting a call. The number selection is done through the handset keypad. The user address for each station and EOW unit is performed locally through the LCT (RS-232) port. The allowed address ranges for the unit are:

2 digits: from 10 to 99 3 digits: from 100 to 999

Ranges from 01 to 09 and 001 to 099 are reserved. To ensure compatibility towards PDH networks of previous generations (connected through analog 4-wire+E&M) extensions it is necessary to dial “*” before entering the station address of the PDH network. The same procedure must be employed when the user wants to connect to networks equipped with selective call units using more than 2 or 3 digit numbering plans. When the interconnection with EOW channels of SRAL networks is required, it will be necessary to connect only the phone wires (Tx+Rx) of both equipment on the analog 4-Wire interfaces. With a suitable cable, cross-connect only the TX with RX on both sides, leaving E&M wires open.

Page 11: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 11/45 Ed. Cover: 06

8.2 Line engagement The line engagement by the user happens automatically when going off-hook. The user will receive, in case of free line, the “free” continuous tone, or the “busy” tone if the line is already engaged. In the first case, on every station of the area, the green Line LED will go ON, and all other users will receive a “busy” tone should they go off-hook. The user has a time limit of 30s ± 5% to dial a number, otherwise the line will be automatically disengaged, and the green led will go off on all EOW units. The calling user will receive a busy tone and will have to hangup and redial again. In case of automatic line disengagement, it is always possible to dial the user that has left the handset off-hook. In this case the called user, to answer, must first hangup and then go off-hook.

8.3 Selective Call In case of selective call it is possible to address the call towards any user of the line, by dialing 2 or 3 digits through the DTMF handset keypad. Every EOW unit, after the reception of 2 or 3 digits, inhibits the reception of other numeric digits. After the selection the calling user receives from the called unit the “call control” tone. The call reception causes the activation of the acoustic announciator and the flashing green line Led, on the called unit. If, within 60s ± 5% of time, the caller does not receive the answering code from the called user, it will automatically generate the line disengage code, switching all green Leds off. The calling user will receive a “busy” tone and the called acoustic announciator will go off; the calling user is always enabled to receive calls. The calling user will have to hangup and go off-hook again to perform another call. When the called user goes off-hook:

1. The answering code will be automatically sent on line. 2. The local acoustic announciator and the call control tone will go off, the green Led will be fixed On. 3. The voice link will be activated

The answering code reception on the calling side will cause: 1. Inhibition of the 60s timer 2. The activation of the voice link

The line will be disengaged when the calling or called party goes on-hook; the other end will receive the busy tone. The line disengagement by at least one user allows the further reception of calls by both parties. If the call is directed to a user whose station address is composed by more than 2 or 3 digits, or belongs to a network that uses E&M signalling, it is necessary to precede the actual number with the “*” DTMF code. This event causes the automatic generation of the answering code by the local EOW unit, with a call evolution similar to the above. There are some special functions available to the user: the inclusion function and the multiple selective call.

Page 12: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 12/45 Ed. Cover: 06

Inclusion Function A selective conversation between two users of the line must be reserved. Anyway, a user not enganged in the same conversation can bidirectionally insert its voice in the ongoing conversation, by keeping the INS button pressed; the insertion will be signalled on line by a permanent inclusion tone. The exclusion from the insertion is obtained by releasing the button or by hanging up the handset. Multiple selective call During a selective conversation between two users, one of them can make an additional call towards a third party, thereby realizing the multiple selective call function. Pressing and releasing the INS key on the front panel, he will locally enable the lighting of the yellow Led, and send on the line the DTMF “D” code, that enables the “presetting to multiple selective call” mode on all EOW units. The voice link between the two users is momentarily suspended, until the emission of the second or third selection digit. Moreover, the calling user can disengage the line before the answer of the third party, by pressing and releasing the INS key (sending the DTMF “C” code). When the inter-digit or the answering timeout has elapsed the calling party will automatically send the “C” code bringing the line back to the selective conversation state. If, during the multiple selective conversation, one of the two users of the originating selective call presses the INS key (sending the DTMF “D” code), it would hangup the additional conversation, bringing the line backto the situation of presetting to multiple selective call (this has the aim to limit the maximum number of users to 3). The evolution of the optical indications on the EOW units, in case of selective call and multiple selective, is show in Table 1.

8.4 Omnibus call In case of omnibus calls, it is possible to address the call to all users of the SRAL or SRA4 service area, by selecting the fixed “00” number with the DMTF handset. After the selection the calling user receives the call control tone locally generated. The call reception automatically connects all the free EOW units to the line with the activation of flashing green and yellow leds, and of the acoustic announciator. If, after a 60s ± 5% time limit, no called party answers, the local acoustic announciator will go off, the green led will be fixed on and the yellow led will continue to flash. The calling user generates the line disengagement code (causing the switchoff of the leds), receives the busy tone but is enabled to the reception of further calls; to perform another call he will have to hangup and go off-hook again. If at least one of the called parties answers and goes off-hook:

1. Locally the acoustic announciator will go off, the green led will be fixed on (only on stations that have answered to the call) and the answer code will be sent to the calling user.

2. The activation of the voice link on the receiving side only The user that answered the call is initially capable of receiving the voice from the calling party. To enable the bidirectional voice link, the called user must press the INS key.

The reception of the answer code by the calling party causes locally:

1. The interruption of the “call control tone” generated locally 2. The interruption of the 60s timer 3. The activation of the voice link

Page 13: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 13/45 Ed. Cover: 06

On all the other connected EOW units, that did not answer to the call, the green and yellow leds will continue to flash and the acoustic announciator will be kept active for a time of 60s ± 5% starting from the beginning of the call. After the above timeout, on all EOW units that did not answer the call, the acoustic announciators will be locally deactivated, the green leds will be fixed on, and the yellow leds will be flashing. The evolution of optical indications on the front panel, in the omnibus call case, is shown in table 2.

9 DTMF signalling codes The DTMF codes sent on the line conform to Recc. ITU-T Q.22 e Q.23. The service telephone units can also generate and detect the DMTF alphanumeric codes A, B, C and D, to perform the proprietary signalling function listed below: DTMF code A: "line engagement"; DTMF code B: "line disengagement" or "line reset"; DTMF code C: "answer to a call" and "reset of call, and presetting to multiple selective call"; DTMF code D: " presetting to multiple selective call and shutdown of any added ongoing conversation".

10 Electromagnetic compatibility and safety The following regulations are satisfied by the EOW equipment.

Emissions

Fenomeno Applicazione Raccomandazione ETSI Classe

Radiated emission

Metallic enclosure EN 301 489-1 EN 301 489-4

B

Conducted emission

DC power input port EN 301 489-1 EN 301 489-4

B

Conducted emission

Signal Port EN 301 489-1 EN 301 489-4

B

Page 14: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 14/45 Ed. Cover: 06

Immunity

Metallic Enclosure (including cables and connectors)

Phenomenon Required Values ETSI Recommandation

RF electro-magnetic field (80 MHz ÷ 2 GHz)

10 V/m IEC/EN 61000-4-3

Magnetic field 3 A/m continuous IEC/EN 61000-4-8

Electrostatic discharge 4 kV contact 8 kV air

IEC/EN 61000-4-2

Page 15: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 15/45 Ed. Cover: 06

Signal ports (V11 data, PC interface,Card Fail alarm, analog expansions)

No special protection level is required because V.11 data and Card Fail alarm have cables with length less than 3 meters; the PC interface cable has only a temporary connection. The analog expansion interfaces 4 Wire + E&M comply with the following table:

Phenomenon Required Values ETSI Recommandation

Fast transients common mode

1 kV IEC/EN 61000-4-4

RF common mode 0,15 MHz to 80 MHz

10 Vrms (injection method shall be selected according to EN 300 489-1 EN 300 489-4)

IEC/EN 61000-4-6

Surges 0.5 kV line to ground IEC/EN 61000-4-5 ITU-T Recc. K.20

Power supply port -48V.

Phenomenon Required Values ETSI Recommandation

Fast transients common mode

1 kV IEC/EN 61000-4-4

RF common mode 0,15 MHz to 80 MHz

10 Vrms (injection method shall be selected according to EN 300 489-1 EN 300 489-4)

IEC/EN 61000-4-6

Surges 2 kV line to ground 1 kV line to line

IEC/EN 61000-4-5

Safety The system complies with the CEI/EN 60950-1.

Page 16: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 16/45 Ed. Cover: 06

11 Technical Features

11.1 General Frequency Range 300 ÷ 3400 Hz

Working mode of local telephone interface 2 wires Working mode through analog extensions 4 wires (DTMF) or 6 wires (phone+E&M) Signalling type (2/3 or more digits) a) In-band call, general, selective and multiple selective

DTMF according to ITU-T Q.23

b) General, selective and multiple selective call through signalling E&M wires

Loop disconnect

Modulation type (towards line) PCM , 7bit encoding Encoding law A-Law Sampling Rate 8 KHz +/- 50 ppm Electrical Interface toward line equipment V11 (Data/clock) Bit rate 64 Kb/s +/- 100 ppm Active call indicator a) General call (omnibus) Flashing Green and Yellow Line Leds b) Selective call Flashing Green Line Led Call generator DTMF Telephone with keypad a) General call (omnibus) Number "00" b) Selective call Numbers from 10 to 99 and from 100 to 999 Line off-hook indicator Fixed Green Line Led ON Access to special functions (multiple selection, inclusion)

INS Key

Acoustic Call Indicator Buzzer a) General call (omnibus) 0.8s signal, 0.8s pause b) Selective call 0.8s signal, 2.4 pause

11.2 Interfaces and electrical characteristics 1) Line side: access to Base Band service byte (line1 and line2) Bit rate 64 Kb/s Level V11 according to ITU-T regulations Clock Frequency 64 KHz Octet Frequency 8 KHz

Page 17: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 17/45 Ed. Cover: 06

Encoding Rule PCM , 7bit encoding Transmission: Interface characteristics Contradirectional; data,clock. Reception: Interface characteristics Codirectional, data,clock. Front panel Access Sub-D 9c female connector (one for each line)

shielded EMC/EMI and safety compliance According to chapter 10 2) Analog extension side 4W+E&M (exp 1 and exp 2) Voice channel Characteristics Connection type 4 wire (Tx + Rx) balanced In/out impedance 600Ω Input Level -7 dBr or –4 dBr +/- 1 dB, software selectable Output Level -7 dBr +/- 1 dB Return loss (measured on real 600Ω) > 14 dB (from 300 to 3400 Hz) Number of extensions 2 E&M signalling wires characteristics : Operation type Loop disconnect Active state Ground potential Signalling frequency 20 Hz +/- 2 Hz Duty-cycle 50/50 Equivalent Circuit of M wire: Closed Circuit (ground):

max 200Ω real in series with a battery of -3V minimum

Open Circuit (floating):

min. 60 KΩ real in series with a battery of +2V maximum

Electrical characteristics of E wire:

Page 18: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 18/45 Ed. Cover: 06

R (on) max 30 Ω Residual voltage in closed state - 2V max Maximum current in closed state 10 mA towards negative voltage Residual current in open state - 200 µA max Maximum applicable Battery voltage -72V EMC/EMI and safety compliance According to chapter 10 Front panel access Double RJ 45 Connector (one for each line),

shielded 3) 2 Wire interface (TIP,RING) towards telephone handset Front panel access to handset Jack socket, Bantam type Supply bridge Voltage - 24V +/- 1V Loop current (off-hook) 20 mA nominal (from 0 to 600Ω of loop

resistance) Handset impedance 375Ω nominal Return loss (measured on 600Ω real) > 18dB (from 300 to 3400 Hz) EMC/EMI and safety compliance According to chapter 10 Levels (channel side on 600Ω real, balanced) Input (transmission) 0 dBr Output (reception) - 4 dBr +/- 1 dB

11.3 DTMF Signalling Type DTMF according to ITU-T Q.23 Acceptable level - 3 dBm MAX, - 24 dBm MIN Frequency deviation tolerated ± 1,5% ± 2 Hz Frequency deviation not tolerated > ± 3,5% Minimum time for signalling acknowledgement

40 ms

Page 19: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 19/45 Ed. Cover: 06

Maximum time for loss of signalling acknowledgement

20 ms

Acceptable interdigit pause 40 ms MIN Unacceptable interdigit pause 20 ms MAX

11.4 Control Tones Tone Characteristics Frequency /type 450 Hz/square wave Free line tone Continuous Busy line tone 0.2s ON/0.2s OFF Call control tone 0.8s ON/2.4s OFF Inclusion tone 0.2s ON/0.2s OFF/0.2s ON/1s OFF

11.5 Card Fail Alarm Operation type Loop disconnect Active State/ Normal State Open Circuit / Ground Contact Overvoltage Protection According to chapter 10 Output wire electrical characteristics R (on) max 30 Ω Residual voltage in closed state - 2V max Maximum current in closed state 10 mA towards negative or positive voltage Residual current in open state - 200 µA max Maximum applicable battery voltage -72V

11.6 Operating voltage and power consumption External supply voltage -48V ± 20% EMC/EMI and safety compliance on Vbatt cables

According to chapter 10

Maximum power consumption (in conversation mode)

≤ 3.0 W @ -48V

Page 20: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 20/45 Ed. Cover: 06

12 Mechanical characteristics and Front Panel Description

This section describes the mechanical characteristics of the EOW unit. The EOW unit comes with a sub-rack mounting unit, suitable for 19” rack or ETSI-N3 mounting. Included in the kit are the adapting brackets, for extending the 19” rack format to the ETSI-N3 width. The basic equipment includes one EOW unit, mounted on the left side of the sub-rack. There is a spare slot for an additional EOW unit to be mounted on the right side. The assembled EOW unit has the following dimensions (mm): 44Hx442Lx110D The EOW unit has the following electrical interfaces on the front panel:

Telephone (TIP,RING) Bantam jack, female V11 64kbit/s Lines Shielded sub-D 9c connector, female 4W analog lines RJ45 90° connector, shielded, female LCT (RS232) Shielded sub-D 9c connector, female Power Input (-48 V) Sub-D power supply connector 90°, male, three contacts

The following LEDs are present on the front panel:

1. Green LED showing Line Status (ON-Hook/ OFF-Hook) 2. Yellow LED showing incoming calls or call inclusion 3. Red LED for Card Fail alarm, Green LED for normal operation

Exp1 Exp 2

L 2

L 1

INS

210

PWR (-48V) LCT μTEL Line status

SIEMENS EOW

+ -

Figure 4 - EOW: Front panel and general layout (dimensions in mm.)

Page 21: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 21/45 Ed. Cover: 06

44

442

110

Figure 5

Page 22: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 22/45 Ed. Cover: 06

13 LED Table

CALLING PARTY CALLED PARTY INCL. PARTY

SITUATION/STATE

LINE (green)

LINE (yellow)

LINE (green)

LINE (yellow)

LINE (green)

LINE (yellow)

1 Line off-hook ON -- ON -- ON --

2 Selective Call ON -- L -- ON --

3 Answer to Selective Call ON -- ON -- ON --

4 Inclusion on Selective Call ON -- ON -- ON --

5 Presetting to inclusion ON ON ON -- ON --

6 End of selection for inclusion call ON ON ON -- L --

7 Answer to inclusion call ON -- ON -- ON --

8 Hangup of included party ON -- ON -- ON --

9 Hangup of calling party -- -- -- -- -- --

10 Hangup of called party -- -- -- -- -- --

Table 1: EOW LED TABLE FOR SELECTIVE AND MULTIPLE CALLS

LEGEND :L = Flashing Led ;ON = Led fixed on;-- = Led off.

Page 23: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 23/45 Ed. Cover: 06

CALLING PARTY CALLED PARTY ANSWERS

CALLED PARTY DOES NOT ANSWER

SITUATION/STATE

LINE (green)

LINE (yellow)

LINE (green)

LINE (yellow)

LINE (green)

LINE (yellow)

1 Line off-hook ON -- ON -- ON --

2 Omnibus Call ON -- L L L L

3 T< 60 sec. At least one answer ON -- ON L L L

4 T< 60 sec. Inclusion of Called Party ON -- ON ON L L

5 T> 60 sec At least one answer ON -- ON L ON L

6 T> 60 sec. Inclusion of Called Party ON -- ON ON ON L

7 Disinclusion of included party

ON -- ON L ON L

8 Hangup of Called Parties ON -- ON L ON L

9 Hangup of Calling Party -- -- -- -- -- --

Table 2: EOW LED TABLE FOR OMNIBUS CALLS.

LEGEND :L = Flashing Led ;ON = Led fixed on;-- = Led off.

Page 24: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 24/45 Ed. Cover: 06

14 Connections In this chapter are described the typologies and pinout of the connectors present on the front panel of the EOW unit. All the external connectors must be of the shielded type to comply with EMI/EMC regulations. Power supply connector In the following figure is shown the power supply connector, as seen on the front panel of the EOW unit. The corresponding pin function is shown in the table.

Pin 1

Figure 6

Pin number Pin type Signal name

1 Male 48 V (+) 2 Female ------- 3 Male 48 V (-)

Connector type: Shielded SUB-D, 3 poles gold-plated. The central pin is not internally connected. LCT Connector (RS232) This interface is used to connect a local PC (LCT function) to do the initial setup during the installation phase. In the figure below is shown the connector and the pin functions. Note that pin 9, normally not used in LCT connections, is used for Card Fail alarm reporting, after configuration, and left permanently connected while the EOW unit is in service.

Pin 1

Figure 7

Connector type: Shielded SUB-D 9 pin, female on the EOW unit

Pin Signal name I/O Interface type Description

1 F_CD OUT Received Line Signal Detector (Data Carrier Detect), not used, internal pull-up

Page 25: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 25/45 Ed. Cover: 06

2 F_RXD OUT Received Data 3 F_TXD IN Transmitted Data 4 F_DTR IN (LCT Interf.) Data Terminal Ready, not used 5 GND RS-232 Signal Ground 6 F_DSR OUT Data Set Ready, not used, internal pull-up 7 F_RTS IN Request To Send, not used 8 F_CTS OUT Clear To Send, not used, internal pull-up 9 Card_Fail OUT Float./Ground Card fail alarm (Was Ring Indicator)

Bantam Connector It is used to connect the EOW unit with the external telephone handset. The schematic diagram of the internal female connector is shown below:

Figure 8

R: RING wire, T: TIP wire.

V11 Line Connectors These connectors are used to connect the 64 Kbit/s digital signals to/from the EOW unit with the relevant USER access points on the Base-Band units.

Pin 1

Figure 9

Connector type: Shielded SUB-D 9 pin, female on the EOW unit

Pin Signal name I/O Description

8 CKRB. i In Co-directional clock B

3 CKRA. i In Co-directional clock A 7 DRB. i In Co-directional data B

Page 26: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 26/45 Ed. Cover: 06

2 DRA. i In Co-directional data A 9 CKTB. i In Contra-directional clock B 4 CKTA. i In Contra-directional clock

A 6 DTB. o Out Contra-directional data B 1 DTA. o Out Contra-directional data A 5 GND - Ground

Expansion Connectors for analog lines

They are used to connect the analog signals to/from the EOW unit with external equipment.

Exp1 Exp2

pin 1

Figure 10

Connector Type: RJ-45, 8 gold-plated contacts, shielded.

Pin Signal name I/O Description

1 TXa.o Out Analog TX a wire

2 TXb.o Out Analog TX b wire 3 TXGND -- Analog TX GND 4 E.o Out E sign. output 5 M.i In M sign. input 6 RXGND -- Analog RX GND 7 RXa.i In Analog RX a wire 8 RXb.i In Analog RX b wire

Page 27: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 27/45 Ed. Cover: 06

15 Part Numbering The following Siemens codes apply to the EOW unit:

705-102/01 base version including the EOW unit and the subrack 612-910/23 additional EOW unit for subracks equipped with 2 EOW in a single frame

Page 28: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 28/45 Ed. Cover: 06

16 V.11 Polarity and phase relationships

EOW

A

B

A

B

A

B

A

B

(+)

(-)

(+)

(-)

Data

Clock

V11 Data

V11 Clock

EOW to LINE DATA

BASE BAND UNIT

Figure 11

EOW

A

B

A

B

A

B

A

B

(+)

(-)

(+)

(-)

Data

Clock

V11 Data

V11 Clock

LINE to EOW DATA

BASE BAND UNIT

Figure 12

Page 29: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 29/45 Ed. Cover: 06

17 LCT Programming Software – User Manual

17.1 Main Window The following is the starting panel when the program is launched. SCREEN 1.0

Empty boxes will be filled with values selecting the “CONNECT” button and only if the board is connected and powered. “Comm” port value is set to 1 by default. If the Communication Port available is different from the one shown ,selection of the correct value is needed before beginning the link. Suppose to select Comm 5, SCREEN 1.1

Page 30: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 30/45 Ed. Cover: 06

and press “CONNECT”. if the Communication Port selected does not exist or it is not available (because another program is using it) a warning message appears as shown in the following: SCREEN 1.2

Page 31: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 31/45 Ed. Cover: 06

If the Communication Port selected exists and it is available, the “CONNECT” button sets up the link with the board; if the link is valid, a green traffic light appears and the following cells will be filled: - “STATION NUMBER”: - “EXT.i/f LEVELS - “SW UPGRADE” SCREEN 1.3

On the contrary, if the board does not answer the screen is as follows: SCREEN 1.4

Page 32: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 32/45 Ed. Cover: 06

In both cases the link is monitored every 5 seconds in order to detect if the board is still connected (Screen 1.3) or not (Screen 1.4). Pressing “DISCONNECT” Command Button gets back to Screen 1.0 Selecting the left Command Buttons gets to operating submenu.

17.2 “System INFO” Window Pressing “SYSTEM INFO” button produces: Screen 2.0

Page 33: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 33/45 Ed. Cover: 06

The cyclic communication link with the board is disabled and values are freezed at the last ones acquired. “CONNECT” button is disabled until “SYSTEM INFO” window is not closed. Data shown on the 7 labels are read from the board and cannot be modified (read only mode) HW CODE : Level 600 Code UNIT EDITION : Level 600 Edition SERIAL NUMBER: Board Serial Number MANUFACTURER CODE: Manufacturer Code EQUIPMENT CODE : Level 700 Code EQUIPMENT EDITION : Level 700 Edition DATE OF MANUFACTURING: Lev.600 Date of Manufacturing Closing the “SYSTEM INFO” window re-enables the communication link is and gets to Screen 1.3 or 1.4.

17.3 “STATION NUMBER” Window “STATION NUMBER” button gets to screen 3.0 that is placed on the top right side of the Main Window (Screen 1.3 not shown) SCREEN 3.0

Closing the window gets to screen 1.3 “SET” button produces the “ENTER NUMBER” subwindow below the “ STATION NUMBER” window. SCREEN 3.1

Page 34: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 34/45 Ed. Cover: 06

In “ENTER NUMBER” window you can modify the phone number that must be numeric only and made up of minimum 2 digits and maximum 3 digits. The program disables 0 as first digit. Suppose to set up 12 and to press “OK” button. Inside “ENTER NUMBER” window , the frame “ARE YOY SURE” appears with the “NO” and “YES” options. SCREEN 3.2

“ARE YOU SURE” frame disappears if “NO” option is selected and Phone Number can be modified again.

Page 35: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 35/45 Ed. Cover: 06

SCREEN 3.3

On the contrary ,“YES” option in the screen 3.2:

confirms the selected number, closes automatically “ENTER NUMBER” and “STATION NUMBER” windows and updates the new value on the main windows that appears as follows:

SCREEN 1.3a

This operation updates the Board Flash too.

Page 36: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 36/45 Ed. Cover: 06

17.4 ”EXT i/f LEVELS” Window “EXT i/f LEVELS” button gets to screen 4.0 that is placed on the low right side of the main window (Screen 1.3 not shown) SCREEN 4.0

Closing the window gets back to screen 1.3 The EXT.LINE 1 and EXT.LINE 2 can be modified with the corresponding “SET” button. A “List Box” that shows the two possible values (-7,-4) adds up on the EXT LINE section selected : the ‘blue’ value refers to the last value set. Suppose to press the EXT.LINE 1 “SET” button SCREEN 4.1

It is possibile to select in the “List Box” another value or the same value. Suppose to set -4 for Ext.Line 1 and press the corresponding “OK” button

Page 37: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 37/45 Ed. Cover: 06

The panel appears as follows: SCREEN 4.2

The “ARE YOU SURE” frame with “NO” and “YES” options appears. “NO” option closes the “ARE YOU SURE” frame and gets back to Screen 4.1 Selecting “YES” produces:

“ARE YOU SURE” frame gets not visible “Save New Values” button gets visible The “List Box” selected value is written in the “Current Level (dBr)” label

SCREEN 4.3

Page 38: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 38/45 Ed. Cover: 06

This operation is not enough to produce the effective modification of the parameter on the board Flash. Closing the window at this point gets back to screen 1.3 without any modification. Only “Save New Values” validation button, if pressed, updates, on the board Flash, the “EXT.LINE x” selected parameter that is ,at same time, copied in the main window that appears as follows SCREEN 1.3b

17.5 “SW UPGRADE” Window “SW UPGRADE “ button produces the window shown in : SCREEN 5.0

Page 39: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 39/45 Ed. Cover: 06

Closing the window gets back to screen 1.3 Pressing the Red Key

enables the “Common Dialog Window” SCREEN 5.1

Page 40: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 40/45 Ed. Cover: 06

By default “Cerca in” directory points to the EOW program location (e.g. “Siemens”) The “Tipo di file” selected is EOW Firmware (*.bin) Only *.bin files are listed inside “List File Box” ( e.g.

Reowsw20.bin Reowsw21.bin

) “Annulla“ button closes this window and produces the following warning message

Suppose to select the new file REOWSW21.BIN

Page 41: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 41/45 Ed. Cover: 06

In the “SW UPGRADE “window more objects add up: SCREEN 5.2

- “Transferring REOWSW21.BIN to target” label - Transferring Starting Time Label (“Begin: hh.mm.ss”) - “Line xxxx/yyyy” label where xxxx is the current transferred line (32 bytes) and yyyy is the total line number - “Progressive Bar” indicating the transferring current percentage - “New Version CRC16” frame where - the “File” section shows the CRC16 referred to the file that has been downloaded ( as calculated by the VB program) - the EOW section shows xxxx When download is complete the panel is as follows: SCREEN 5.3

Page 42: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 42/45 Ed. Cover: 06

The new window objects are:

- Transferring Ending Time Label (“End: hh.mm.ss”) - Transfer time duration (“Time:xxx”) - “Done” label

Moreover

- the “Line xxxx/yyyy” label is updated with the total transferred lines - the “Progressive Bar” indicates the 100% of the transfer. - In the “New Version CRC16” frame, the EOW section shows the CRC16 of the transferred file as

calculated by the old board firmware If there is matching between CRC16 file section and CRC16 EOW section two new objects appear:

- The “Step 1 Succesfully Completed” label - The frame ”STEP 2 WILL LOAD KERNEL AND UPGRADE CURRENT VERSION ARE YOU

SURE TO CONTINUE” with “NO” and “YES” options “NO” option produces the following panel: SCREEN 5.4

Page 43: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 43/45 Ed. Cover: 06

and gets back to screen 1.3 “YES” button enables effective transfer of the new firmware from Flash temporary section to Flash boot section The message

Wait… Transfer in progess! DO NOT DISCONNECT TARGET!

blinks on screen as follows SCREEN 5.5

Page 44: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 44/45 Ed. Cover: 06

The yellow led of the board blinks at high frequency. When the transfer is complete the board resets itself and the VB program order to the new firmware of the board to calculate the CRC of the boot section. If the CRC is correct (i.e.it is the same as in the “File” section) the last window appears SCREEN 5.6

Closing the window the main window is updated with the new firmware version written at “Current Version” label. SCREEN 5.7

Page 45: EOW Manual_draft_new

© Copyright Siemens Mobile Communications S.p.A. 2005 - All rights reserved

Author : EOW User Manual Version:0 Revision:1 Code : IMC0181AEDG LCT Software User Manual Date : 2004-07-26 09:18:16 pag. 45/45 Ed. Cover: 06