epcos product brief 2015 power factor correction product brief 20… · epcos product brief 2015...
TRANSCRIPT
www.epcos.com
EPCOS Product Brief 2015
Power Factor CorrectionPower Quality Solutions
PQS key componentsfrom EPCOS cover
the entire range of productsneeded for successful powerfactor correction.All parts are carefully matchedto each other. With this uniqueport folio, EPCOS is more thana sup plier of products:Power Quality Solu tions is thestrategy that has been devel-oped to fulfill the demand of themarket to offer solutions ratherthan single components. This product brief gives anoverview of all PQS productsfor power factor correction. For detailed information, pleaserefer to the PFC Product Profileand data sheets, available in theInternet at www.epcos.com/pfc,or contact our local sales office.
PQS key components� PFC capacitors
– PhaseCap Premium/Compact/HD, DeltaCap,PhiCap, PoleCap
� Power factor controllers andmeasuring devices– BR604, BR6000, BR7000,
BR7000-I– MMI6000, MMI7000 and
MMI8003– Grid analysis tool MC7000-3
� Capacitor contactors– J230/N230 series
� Thyristor modules for dynamic PFC– TSM-LC and TSM-HV series
� Active harmonic filter– PQSine
� Reactors– Antiresonance harmonic filter– Discharge reactor
� Accessories
2 © EPCOS AG 2015
Power Factor Correction:Capacitors
Technical data
Series PhaseCap Premium PhaseCap Compact PhaseCap HD
Premium power capacitors for Compact power capacitors for High-density power capacitors for low-voltage power factor correction low-voltage power factor correction low-voltage power factor correction
Features
Technology MKK MKK MKK
Inrush current High pulse current withstand High pulse current withstand High pulse current withstandcapability up to 300 · IR capability up to 400 · IR capability up to 300 · IR
Discharge resistor/ Ceramic discharge resistor Ceramic discharge resistor External discharge modulemodule pre-mounted up to 660 V AC; pre-mounted; external discharge pre-mounted
external discharge module module for types ≥ 690 V≥ 690 V AC
Safety system Triple: Dual: Triple:• Self healing • Self healing • Self healing• Overpressure disconnector • Overpressure disconnector • Overpressure disconnector• Dry technology • Dry technology
Impregnation Inert gas, dry, non-PCB Semi dry biodegradable resin, Inert gas, dry, non-PCBnon-PCB
Rated voltage VR 230 … 800 V AC 230 … 1000 V AC 400 … 525 V AC
Power QR 5 … 33 kvar 5 … 37.1 kvar 40 … 60 kvar
Rated frequency fR 50/60 Hz 50/60 Hz 50/60 Hz
Winding Concentric Concentric (S-types stacked) Stacked
Mounting position Upright/horizontal Upright/horizontal1) Upright
Ordering code B25667C* B25673A* B25669*B25673S*
Applications
• Automatic PFC equipment • Automatic PFC equipment • Automatic PFC equipment• Individual fixed PFC • Individual fixed PFC • Individual fixed PFC• Fixed PFC • Fixed PFC • Fixed PFC• Tuned and detuned capacitor • Tuned and detuned capacitor • Detuned capacitor banks
banks banks• 690 and 800 V AC series for • 690 to 1000 V AC series for
usage in harsh application usage in harsh application conditions, e. g. industrial conditions, e. g. industrial applications with heavy harmonic applications with heavy harmonic loads loads
1) PhaseCap Compact S-types and DeltaCap: when mounting in horizontal position, additional mechanical support is recommended to prevent breaking of mounting bolt in case of mechanical shock or vibrations. This support should be placedat short distance below the bead at the top end of the capacitor.
3© EPCOS AG 2015
Power Factor Correction:Capacitors
Technical data
Series DeltaCap PhiCap PoleCap
Power capacitors for Power capacitors for Power capacitors for outdoorlow-voltage power factor correction low-voltage power factor correction applications or harshin industrial applications environmental conditions
Features
Technology MKD MKP MKP/MKK
Inrush current High pulse current withstand High pulse current withstand High pulse current withstandcapability up to 200 · IR capability up to 200 · IR capability up to 200 · IR
Discharge resistor/ Discharge module included Ceramic discharge resistor Integrated discharge resistormodule in delivery, integrated in pre-mounted for B32344E series;
terminal for B32304A****A***-series discharge resistors included in delivery for other series
Safety system Dual: Dual: Triple:• Self healing • Self healing • Self healing• Overpressure disconnector • Overpressure disconnector • Overpressure disconnector
• Dry technology
Impregnation Semi-dry biodegradable soft resin, Semi-dry biodegradable soft resin, Inert gas, non-PCBnon-PCB non-PCB
Rated voltage VR 230 … 525 V AC 230 … 525 V AC 400 … 525 V AC
Power QR 0.5 … 33.7 kvar 0.5 … 30 kvar 0.5 … 30 kvar
Rated frequency fR 50/60 Hz 50/60 Hz 50/60 Hz
Winding Stacked Stacked MKP: stackedMKK: concentric
Mounting position Upright/horizontal1) Upright Upright/horizontal
Ordering code B32300C* series: B32340C* series: B25671A*Single phase, fast-on terminals Single-phase, fast-on terminalsB32303C* series: B32343C* series:Single phase, fast-on terminals Three-phase, fast-on terminalsB32304* series: B32344E* series: Three phase, screw terminals Three-phase, optimized capacitor
safety terminals
Applications
• Automatic capacitor banks • Fixed PFC• Detuned PFC systems
• Automatic capacitor banks• Fixed PFC applications, e. g.
motor compensation• AC power electronics• Tuned and detuned PFC
systems• Approvals: VDE-approval
• Pole mounted PFC, i.e.outdoor applications
• Fixed PFC inside or outside acabinet in surroundings with highdust or moisture concentrations
• Automatic PFC systems toreduce labor costs
1) PhaseCap Compact S-types and DeltaCap: when mounting in horizontal position, additional mechanical support is recommended to prevent breaking of mounting bolt in case of mechanical shock or vibrations. This support should be placedat short distance below the bead at the top end of the capacitor.
4 © EPCOS AG 2015
Power Factor Correction:Accessories
Accessories
Plastic protective case Plastic protective terminal cover Discharge resistors and modulesmodules for capacitor series
Features
Ordering code
Protection class IP54
PhaseCap Premium capacitors
Protection class IP54
PhaseCap PremiumPhaseCap Compact(n/a for Ø 100 mm)
Capacitor d x h:116 x 164 mm: B44066X9122116 x 200 mm: B44066X9142136 x 200 mm: B44066X9142
PhaseCap:Capacitor d x h:116 x 164 mm: B44066K0135A000116 x 200 mm: B44066K0160A000136 x 200 mm: B44066K0210A000
PhiCap:Capacitor Ø:53 mm: B44066K0530A0001)
63.5 mm: B44066K0635A0001)
75 mm: B44066K0795A00085 mm: B44066K0895A000
Available on request for PhaseCapPremium, PhaseCap Compact,PhaseCap HD, PhiCap B32344series.
On request
1) Protection class IP20
5© EPCOS AG 2015
Power Factor Correction:Key Components
Technical data
Series Power Factor Controllers Power Factor Controllers BR604 and BR6000 V6.0 BR7000 and BR7000-T
Features
Technical data
• Supply voltageBR604: 230 V AC, 50/60 Hz BR6000: 110 … 230 V AC, 50/60 Hz
• Measuring voltage: BR604: = supply voltage 230 V AC BR6000: 30 … 525 V AC (L-N) or (L-L)
• Sensitivity: 50 mA/10 mA
• Measuring current BR6000: X:5 A / X:1 A
Ordering code
BR604 (4 steps) B44066R6004E230
BR6000-R6 (6 steps) B44066R6006E230
BR6000-R12 (12 steps) B44066R6012E230
BR6000-HD6 B44066R6506E230
BR6000-HD12 B44066R6512E230
BR6000-T6 B44066R6106E230(6 steps for dynamic PFC)
Three-phase measuring
Three-phase display of numerous parameters as real value and in %
Controlling three-phase, single-phase, mixed mode
2 isolated interfaces
Illuminated graphic display, 128 x 64 dots, 8 lines
Menu driven handling (plain language)
HELP-button for interactive help text
BR7000 for conventional PFC systems
BR7000-T for dynamic PFC systems
• Supply voltage: 110 … 230 V AC, ±15%, 50/60 Hz
• Measuring voltage:3 · 30 … 440 V AC (L-N);3 · 50 … 760 V AC (L-L), 50/60 Hz
• Measuring current: 3 · X:5 A / X:1 A, selectable
• Operating ambient temperature: –20 … +60 °C
BR7000: • 15 switching outputs• 3 additional alarm/message relays• 2 independent interfaces
BR7000-T:• 15 transistor outputs• 3 additional alarm/message relays• 2 independent interfaces
Evaluation software BR7000-SOFT incl. in the delivery
Versions BR7000-HD and BR7000-T-HD with OLED display
BR7000 B44066R7415E230
BR7000-HD B44066R7515E230
BR7000-T B44066R7615E230
BR7000-T-HD B44066R7715E230
PC software BR7000-SOFT see page 6.
Large and multifunctional display(2 x 16 characters, backlight for BR6000 series)BR6000-HD with OLED display
Menu driven handling (plain language)
Self-optimizing control capability
Recall function of recorded values
Automatic initialization possible for BR6000
6 © EPCOS AG 2015
Power Factor Correction:Key Components
Technical data
Series Power Factor Controller Power Factor ControllersBR7000-I BR7000-I-TH and BR7000-I-TH/S485
Features
Technical data
Supply
Ordering code
PC software BR7000-SOFT
Single-phase measuring
Illuminated graphic display, 128 x 64 dots, 8 lines
Menu driven handling (plain language)
HELP-button for interactive help text
BR7000-I standard version
BR7000-I/S485 with interface RS485
Measuring device mode for simultaneous display of 3 parameters (large display also)
3-digit display of the power factor (cos f) / switchable display as tan f
Display of values as bargraph-diagram possible
• Supply voltage: 110 … 230 V AC, ±15%, 50/60Hz
• Measuring voltage:30 … 440 V AC (L-N); 50 … 760 V AC (L-L), 50/60 Hz
• Measuring current: X:5 A / X:1 A, selectable
• Operating ambient temperature: –20 … +60 °C
• 12 relay outputs for capacitor
• 1 relay output (message/alarm/fan)
• Standard system interface (e.g. for firmware update)
BR7000-I/S485: • Additional external input
• Additional message relay
• Serial interface RS485
• Evaluation software BR7000-SOFT incl. in the delivery
BR7000-I B44066R7012E230
BR7000-I/S485 B44066R7112E230
Single-phase measurement
Illuminated graphic display, 128 x 64 dots, 8 lines
Menu driven handling (plain language)
HELP-button for interactive help text
Suitable for dynamic and mixed compensation
Direct triggering of up to 32 thyristor switches seriesTSM-LC-S (version S485) at the bus
Measuring of important grid parameters
Measuring of distortion factor THD-V/THD-I
Display of harmonics up to 33rd
Display of values as bargraph-diagram possible
• Supply voltage: 110 … 230 V AC ±15%
• Measuring voltage: 30 … 440 V AC (L-N) / 50 … 760 V AC (L-L)
• Measuring current: X:5 A / X:1 A, selectable
• 12 relay outputs
• 12 transistor outputs
• 1 relay output (message/alarm/fan)
• Standard system interface (e.g. for firmware update)
BR7000-I-TH/S485: • Additional external input
• Additional message relay
• Serial interface RS485
• Evaluation software BR7000-SOFT incl. in the delivery
BR7000-I-TH B44066R7412E230
BR7000-I-TH/S485 B44066R7612E230
Connection to RS485 of BR7000, BR7000-I/S485 and BR7000-I-TH/S485
Administration of several PF controllers possible
Comfortable analysis of recorded values
Direct connection to USB port of a PC via USB-adapter
Included in the delivery of BR7000, BR7000-I/S485 and BR7000-I-TH/S485
7© EPCOS AG 2015
Power Factor Correction:Key Components
Technical data
Series
Features
Technical data
Ordering code
Multi Measuring InterfaceMMI7000
Three-phase measuring and display of numerous parameters: V, I, P, Q, S, cos φ, f, W, T, THD-V, THD-I
Display of harmonics as bar chart: harmonic of voltage up to 51st and harmonic of current up to 51st
Oscilloscope mode: for graphic display of a completeoscillation incl. harmonics
Display editor: for free programming of display formeasured values
Scan mode: for rotating display of selected values
Display and recording of minimum and maximum values with time stamp
Panel mounting instrument
Graphical menu (DE/E/ES/RU/TR)
Integrated help function
Display of date and time
• Supply voltage: 110 … 230 V AC ±15%
• Measuring voltage (3-phase):3 · 30 … 440 V AC (L-N)3 ·50 … 760 V AC (L-L)
• Measuring current: X:5 A / X:1 A
• Rated frequency fR: 50/60 Hz
• Power consumption: < 5 VA• Sensitivity: 50 mA/10 mA• Illuminated full graphic LCD display,
128 x 64 dots
MMI7000-B (basic version): B44066M7100E230
MMI7000-S (incl. 2 interfaces RS485): B44066M7200E230
MMI7000-E (extended version with additional interface, memory card and additional in- and outputs):B44066M7300E230
Multi Measuring InterfaceMMI6000
Single-phase measurement of V, I, P, Q, S, cos f,f, W, T (read out via RS485)
Coupling with PF controller BR7000 and BR7000-I-TH/S485 via interface for determination of real capacitor current
Capacitor protection by step switch-off at current limit
Fast trigger for dynamic PFC
Independent switching of a single capacitor step
Stand-alone measuring device with interface for read-out
Panel mounting instrument
Recording of maximum values
• Supply voltage: 230 V AC
• Measuring voltage: 230 V AC ±15%
• Measuring current: X:5 A / X:1 A
• Rated frequency fR: 50/60 Hz
• Power consumption: < 4 VA• Sensitivity: 40 mA• LCD display 2 x 16 characters; alphanumeric
MMI6000-R (version with relay output):B44066M6000E230
MMI6000-T (version with transistor output):B44066M6100E230
8 © EPCOS AG 2015
Power Factor Correction:Key Components
Technical data
Series
Features
Technical data
Ordering code
Grid Analysis ToolMC7000-3
Measuring, display and storage of numerous parameters
Illuminated full graphic display, 128 x 64 dots
Comfortable programming of recording interval
Display and internal storage of max. values with time stamp
Display of date and time
Large number of display options
Fast and easy evaluation of measured values,with PC software included in the delivery
Automatic calculation of required kvar
Recommendation for design of customized PFC system
• Supply voltage (auxiliary voltage): 110 … 230 V AC
• Measuring voltage (3-phase):3 · 30 … 440 V AC (L-N)3 · 50 … 760 V AC (L-L)
• Power consumption: < 5 A
• Large number of accessories included:3 safety measuring cables1 safety measuring line4 safety dolphin clipsWindows-based software on CD-ROM1 memory SD-Card 1 power lead
B44066M7777E230
Ordering code for flexible current clamps (not included in the delivery, but mandatory for operation): please refer to page 11.
Multi Measuring InterfaceMMI8003
Three-phase grid measuring device in panels, e. g.feed-ins (V, I, P, Q, S, cos φ, f, W, T, THD-V, THD-I)
Measuring of power and harmonics
For integration into existing networks via interfaceRS485 (MODBUS-RTU)
Compatible with software MMI-energy for storage, display and evaluation of power and energy data
Voltage harmonics up to 39th order
Current harmonics up to 39th order
Additional internal 24-hrs-ring buffer for the 15-min active energy values
Internal storage for cumulated energy values
Ring buffer for daily meter reading active power
System clock for time stamp
System interface RS485 (MODBUS-RTU) for processing of measured values
• Supply voltage: 24 V DC (external via terminal)
• Measuring voltage: 3 · 30 … 440 V~ (L-N), 50/60 Hz (10 … 80 Hz)3 · 50 … 690 V~ (L-L), 50/60 Hz (10…80 Hz)
• Measuring current (3-phase): 3 · X:5 A / X:1 A, selectable
• Power consumption: < 5 A
• Sensivity: 50 mA/10 mA
• RS485 system interface
B44066M8003E024
9© EPCOS AG 2015
Power Factor Correction:Key Components
Technical data
Series Capacitor Contactors Thyristor Modules forJ230/N230 Dynamic PFC
Features
Technical data
TSM-LC-I:• Output at: 230 V = 10 kvar, 400 V = 16 kvar,
440 V = 18 kvar, 480 V = 20 kvar, 525 V = 22 kvar
TSM-LC10:• Output at 380 … 400 V: 10 ... 22 kvar
TSM-LC100:• Output at 380 … 400 V: 100 kvar
TSM-LC200:• Output at 380 … 400 V: 200 kvar
TSM-LC-N: • Output at 380 … 400 V: 25 … 50 kvar
TSM-LC-S: • Output at 200 … 440 V: up to 55 kvar
TSM-LC-N690: • Output at 380 … 690 V: 40 … 75 kvar
depending on the voltage
TSM-HV: • Output at 690 V: 50 and 200 kvar
Ordering code
J230 series B44066S****J230
N230 series B44066S****N230
TSM-LC-I: B44066T1022E520
TSM-LC10: B44066T0010E402
TSM-LC100: B44066T0100E402
TSM-LC200: B44066T0200E402
TSM-LC-N: B44066T3050E402
TSM-LC-S: B44066T1050E402
TSM-LC-N690: B44066T3050E690
TSM-HV: B44066T0050E690B44066T0200E690
• Voltage: 400 … 690 V
• Output: 12.5 … 100 kvar
• Auxiliary contacts: included (normally open)
• Mounting: integrated DIN-rail
• Approval: cUL, CCC (up to 75 kvar)
Series J230: with pre-charge resistors for conventionalPFC systems without reactors
Excellent damping of inrush current
Soft switching of capacitors to increase the life expectancy of PFC systems, contactors and capacitors
Reduced ohmic losses
High safety standards
Reduction of voltage sags and transients
Series N230: without pre-charge resistors for detunedPFC systems
Easy installation: usage similar to a contactor
Ultra-short reaction time, almost no inrush current
Switching time: approx. 5 ms
Permanent self controlling of various parameters:• Voltage• Phase sequence• Capacitor output
Display of• Operation• Faults• Activation
• Maintenance-free• Long service life• No switching noise
TSM-LC-I for single-phase
10 © EPCOS AG 2015
Data logger DataLOG SD USB to RS485 converter RJ45 adapterPF controller PF controller PF controller BR7000, BR7000-I/S485 and BR7000, BR7000-I/S485 and BR7000, BR7000-I/S485 and BR7000-I-TH/S485 BR7000-I-TH/S485 BR7000-I-TH/S485
Multi Measuring InterfaceMMI6000/MMI7000
Features
Ordering code
B44066R1311E230 B44066R3333E230
Power Factor Correction:Accessories
Accessories
Usage for PF-controllers, BR7000, BR7000-I/S485 andBR7000-I-TH/S485
• Recording of all grid parametersas well as of all relevant parame-ters of a compensation system,including switching sequences,switching on-time of all steps and temperature
• Direct connection to the controllerinterface via Ethernet cable ispossible; 0.5 m cable is included
• Recording time up to severalweeks
• Ready to use with a plastic casing
• Dimensions 66 x 28 x 66 mm
• Recording of measured values on SD-card (included)
• Evaluation of values withWindows based software, included in the delivery
For connection of BR7000, BR7000-I/S485 and BR7000-I-TH/S485 with interfaceRS485 to PC with USB-interface
• Connection of several devices at RS485 possible
• For usage of software BR7000-SOFT on PC
3 versions available:• Connection to the interface
terminals of BR7000, BR7000-I/S485 and BR7000-I-TH/S485, MMI6000 or MMI7000 via LAN cable
• Simple connection of severaldevices via the RS485 bus,for example:– Connection of several BR7000,
BR7000-I/S485 or MMI7000 to a PC with BR7000-SOFT software
– Interconnection of severalMMI6000/MMI7000
Suitable for: 1xRJ45 for BR7000, BR7000-I/S485, BR7000-I-TH/S485, MMI7000
Suitable for:2xRJ45 for BR7000, BR7000-I/S485, BR7000-I-TH/S485, MMI7000
Suitable for: 2xRJ45 for MMI6000
1xRJ45 for BR7000, BR7000-I/S485,BR7000-I-TH/S485, MMI7000:B44066R1611E230
2xRJ45 for BR7000, BR7000-I-TH/S485, MMI7000:B44066R1711E230
2xRJ45 for MMI6000:B44066R1811E230
11© EPCOS AG 2015
Power Factor Correction:Accessories
UCM-5, MMI-energy EW-22 BD-xxx Flexible current clampsPF controller Thyristor modules Grid analyzing tool MC7000-3BR6000/BR7000 TSM seriesMulti Measuring InterfaceMMI6000/MMI7000/MMI8003
Features
Ordering code
B44066R1411E230
Accessories
Discharge resistor block EW-22Discharge resistor for all types ofTSM-LC to achieve fastdischarging. At least one pieceper step required.
Current limitation reactor BD-xxx(not suitable for TSM-HV)Protection of thyristor modules inPFC systems without reactorTSM-LC-I: 1x BD-50*)
TSM-LC10: 2x BD-50*) or 2x BD-100
TSM-LC100: 2x BD-200TSM-LC-N: 2x BD-100TSM-LC-S : 2x BD-100
Feed-in moduleRequired for voltage supply ofTSM-LC-S (one per 10 switches) for feed-in of power pack 24 V DC
1x Flexible current clamp“Mini-Flex MMI7000-3”
3x Flexible current clamps“Mini-Flex MMI7000-3”
Discharge resistor block EW-22:B44066T0022E400Current limitation reactor BD-xxx:B44066T0***E400Feed-in module ESP24:B44066T0002E400
1x Flexible current clamp:B44066M1301E2303x Flexible current clamps:B44066M1303E230
Recording and evaluation of counter values for processing (via RS485 interface) to PF controllerBR6000/BR7000.Bus compatible S0-impulse module for software MMI-energyand BR6000/BR7000 for conversion of counter impulses(Q+, Q–, P+, P–, synchronic) onRS485 (MODBUS-RTU protocol)Accessory for the processing of counter values in the PF-controller (controlling of reactivepower related to counter impulsesinstead of current transformer)Allows processing of counter values via Windows-software MMI-energy (included in the delivery): cost centre management,visualization and evaluationCross-linking of up to 32 devices(UCM-5, MMI6000, MMI7000) atMODBUSEvaluation software MMI-energy included in the deliveryEvaluation software MMI-energyfor PC (Windows-compatible, included in the delivery)• Storage, display and evaluation
of power and energy data on PC• Single user and network solution
available• Graphical and numerical cost
centre evaluation• Supports UCM-5, MMI6000,
MMI7000, MMI8003, BR6000,BR7000 at one bus (up to max. 32 devices possible)
• Zoom function, print function• Parameterization of the device *) BD-50 production only after ordering
12 © EPCOS AG 2015
Power Factor Correction:Key Components
Technical data
Series Reactors – Reactors – Antiresonance Harmonic Filter Discharge Reactor
Features
Technical data
Ordering code
B44066D* B44066E9900L001
• Voltage: 400 V, 440 V, 690 V
• Frequency: 50 or 60 Hz
• Output: 10 … 100 kvar
• Harmonics (duty cycle = 100%):V3 = 0.5% VRV5 = 6.0% VRV7 = 5.0% VRV11 = 3.5% VRV13 = 3.0% VR
• Effective current: Irms = ��(I12+l32 ... l132)
• Fundamental current: I1 = 1.06 · IR(50 Hz or 60 Hz current of capacitor)
• Temperature protection: microswitch (NC)
• Detuning factor: 5.67%, 7%, 14%
• Voltage: 230 … 690 V
• Frequency: 50/60 Hz
• Discharge time (t):
230 V:up to 25 kvar < 10 sup to 50 kvar < 20 sup to 100 kvar < 40 s
400 … 525 V:up to 25 kvar < 5 sup to 50 kvar < 10 sup to 100 kvar < 20 s
525 … 690 V:up to 25 kvar < 3 sup to 50 kvar < 6 sup to 100 kvar < 12 s
High harmonic loading capability, very low losses
High linearity to avoid choke tilt, low noise emission
Fast discharge for fast reconnection of capacitors
Reduced losses
Shockproof case for DIN-rail mounting
13© EPCOS AG 2015
Power Quality Solutions:Key Components, Systems and Modules
Technical data
Series Active harmonic filter, systems and modulesPQSine
Features
Harmonic compensation up to 50th harmonic (individually selectable)
Flicker compensation
Ultra-fast reactive power compensation (inductive and capacitive)
Active load balancing
Compact design
60 Amps modules or modular systems extendable from 60 to 600 A
Grid resonance detection
Advanced digital control with SDC (Selective Direct Control) algorithm
High performance and reliability
User-friendly menu operation
Simple installation
Technical data
Ordering code
B44066F****N***
Applications
• System input / number of phases: 3-phase / 3-wire; 3-phase / 4-wire
• Input voltage (min. / max.): 3P3W device: 180 V … 528 V, 3P4W device: 180 V … 460 V
• Inverter technology: Three-level NPC topology, IGBT
• Frequency: 50/60 Hz ±3 Hz
• Reaction time: 21 µs (immediate load change reaction)
• Steady state response time: < 300 µs (steady state response time to full steady state compensation)
• Switching frequency: 24 kHz
• Control frequency: 48 kHz
• Interface: Ethercat 100 Mbit/s, USB, active sensor bus, display bus
• Ambient temperature: –10 … +40 °C full performance, up to +55 °C derating 2%/K
• Protection class: IP20 for module and panels, IP54 for floor-mounted panels is optionally available on request
• Datacenters, UPS systems, Green energy power generation(e. g. Photovoltaic and Wind turbines),
• Industrial production facilities, office buildings and shopping center
14 © EPCOS AG 2015
Power Quality Solutions:Key Components and Accessories
PQSine series – accessories
TFT color control/display touch screen unit1) TFT color control/display touch screen unit1)
(7”/12.1”) in rugged equipment case (7” / 12.1”)
Features
Ordering code
For mounting in the panel front
• Protection class: IP65
• LED backlight
• Intensity: 450 cd/m²
• Input: touch screen 4-wire resistive
• For parameter setting, status indication, alarm setting, monitoring, event logging
• Operating system: embedded Linux
• Communication: Ethercat Master, Ethernet TCP/IP
• Interface: USB, 3x opto-insulated input, 2-relay output display bus
• Operating temperature: –20 … + 55 °C
• Firmware update via SD card possible
• Dimensions (W x H x D): 230 x 168 x 56 mm (7”); 340 x 270 x 53 mm (12.1”)
• Weight: 1 kg (7”); 2 kg (12.1”)
7" TFT color control/display unit, touch screen:B44066F9007N230
12.1" TFT color control/display unit, touch screen:B44066F9012N230
Needed for parameterization of PQSine modules ordered without the 7” / 12.1” TFT color control / display touch screen unit, for instance
7" TFT: for parameterization of the PQSine moduleswithout display, including power supply:B44066F9907N230
12.1" TFT: for parameterization of the PQSine moduleswithout display, including power supply:B44066F9912N230
Important information: Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products. We expressly point out that these statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. It is incumbent on the customer to check and decide whether a product is suitable for use in a particular application.This publication is only a brief product survey which may be changed from time to time. Our products are described in detail in our data sheets. The Important notes(www.epcos.com/ImportantNotes) and the product-specific Cautions and warnings must be observed. All relevant information is available through our sales offices.
Display of ordering codes for EPCOS products: The ordering code for one and the same EPCOS product can be represented differently in data sheets, data books, other publications, onthe EPCOS website, or in order-related documents such as shipping notes, order confirmations and product labels. The varying representations of the ordering codes are due to differentprocesses employed and do not affect the specifications of the respective products. Detailed information can be found on the Internet under www.epcos.com/orderingcodes
1) Only needed for modules