SPECIFICATION FEATURES Construction Solid-state design means no moving parts and nothing to wear out or replace, providing maintenance-free operation for hundreds of thousands of hours. Optics Custom-engineered optics direct light precisely where needed while minimizing glare. Feedback Telemetry to monitor health and status of each light is enabled through control system capabilities. Customization Multiple control options available for operational flexibility and fan experience effects. Electrical Ultra-low EMI noise generation eliminates interference with surrounding electrical systems. Finish Rugged, weather-tight design ensures durability even in harsh environments. ARENA 550/750 SPORTS LIGHTING The Arena 550 and 750 provide professional caliber sports lighting with features designed with indoor hockey and basketball arenas and similar indoor sports venues in mind. Offering versatility and flexibility, the Arena 550 and 750 deliver controllable, maintenance-free, quality lighting with a great return on investment. DESCRIPTION 15-7/16" [392mm] 17-1/8" [435mm] 15" [381mm] Clearance for 3/4" [20mm] Bolt 2-7/8" [73mm] Slot diameter Clearance for 3/8" Bolt DIMENSIONS CERTIFICATION DATA IP66 Rated RoHS Compliant EPA Effective Projected Area (Sq. Ft.): 1.4 SHIPPING DATA Approximate Net Weight: 45 lbs. (20.41 kgs.) Catalog # Type Date Project Comments Prepared by TD28002EN 2017-04-11 13:57:37

Post on 21-Jan-2019

213 views

Category:

Documents

0 download

Embed Size (px)

TRANSCRIPT

  • SPECIFICATION FEATURES

    ConstructionSolid-state design means no moving parts and nothing to wear out or replace, providing maintenance-free operation for hundreds of thousands of hours.

    OpticsCustom-engineered optics direct light precisely where needed while minimizing glare.

    FeedbackTelemetry to monitor health and status of each light is enabled through control system capabilities.

    CustomizationMultiple control options available for operational flexibility and fan experience effects.

    ElectricalUltra-low EMI noise generation eliminates interference with surrounding electrical systems.

    FinishRugged, weather-tight design ensures durability even in harsh environments.

    ARENA 550/750

    SPORTS LIGHTING

    The Arena 550 and 750 provide professional caliber sports lighting with features designed with indoor hockey and basketball arenas and similar indoor sports venues in mind. Offering versatility and flexibility, the Arena 550 and 750 deliver controllable, maintenance-free, quality lighting with a great return on investment.

    DESCRIPTION

    15-7/16" [392mm] 17-1/8" [435mm]

    15"[381mm]

    Clearance for 3/4" [20mm] Bolt2-7/8" [73mm] Slot diameter

    Clearance for 3/8" Bolt

    DIMENSIONS

    C E R T I F I C A T I O N D A T AIP66 RatedRoHS Compliant

    E P AEffective Projected Area (Sq. Ft.): 1.4

    S H I P P I N G D A T AApproximate Net Weight: 45 lbs. (20.41 kgs.)

    Catalog # Type

    Date

    Project

    Comments

    Prepared by

    TD28002EN2017-04-11 13:57:37

  • Specifications and dimensions subject to change without notice.

    Eaton's Ephesus Lighting125 East Jefferson StreetSyracuse, NY 13202P: 800-573-3600www.eaton.com/ephesus

    TD28002EN2017-04-11 13:57:37

    ARENA 550/750

    Arena 550 Arena 750

    Lumen Output >61,000 >83,000

    System Wattage 550 750

    Input Voltage 277-480 VAC 277-480 VAC

    L70 Hours 160,000 at 25C 160,000 at 25C

    Operating Temperature Range -40C to 55C -40C to 55C

    Surge (Common Mode / Differential Mode) 6kV 6kV

    IP Rating IP66 IP66

    NEMA Rating NEMA 4X NEMA 4X

    Effective Projected Area (EPA) 1.4 (sq. ft.) 1.4 (sq. ft.)

    Approximate Weight 45 lbs. (20.45 kgs.) 45 lbs. (20.45 kgs.)

    NOTES: 1. The specifi cations listed were obtained under optimal testing conditions. Changes in options, features and conditions may result in slightly different performance specifi cations among fi xtures. 2. Weight may vary depending on mounting bracket selection.3. Pure power is required to ensure proper function and lifetime of Eaton fi xtures. Prior to installation, an analysis should be performed to verify site power meets these requirements:

    High frequency voltage should be below -40dB or .01V between 3KHZ and 100KH. High frequency current should be below -50dB or .019A between 3KHz and 100KHz.

    4. If the power does not meet these criteria, waveform correction technology should be used to condition the power. Surge protection alone is not adequate. Eaton will not be liable for damage to fi xtures due to poor power quality. Consult your lighting representative at Eaton for more informaton.

    ENERGY AND PERFORMANCE DATA

    Sample Number: AN-550-2-57-BLK-AM

    Series Model Optics CCT Fixture Color Controls

    AN=Arena 550=550750=750

    2=NEMA23=NEMA34=NEMA45=NEMA5

    57=5700K BLK=Black AM=AirMeshLB10=LandBurst 0-10VLB=LandBurst DMX

    ORDERING INFORMATION

  • The Arena Series delivers consistent, precise, dimmable light to eliminate shadows and maintain uniformity while exceeding the stringent demands of HDTV broadcasting, digital photography and slow-motion recording. Take control of your venue and transform the entire fan and player experience with a solution that embraces the action of the game.

    DESCRIPTION

    SPECIFICATION FEATURES

    ConstructionSolid-state design means no moving parts and nothing to wear out or replace, providing maintenance-free operation for hundreds of thousands of hours.

    OpticsCustom-engineered optics direct light precisely where needed while minimizing glare.

    HDTV OptimizedExceeds national HDTV requirements. Zero flicker up to 8K frames per second for super-slow motion recording.

    CustomizationMultiple control options available for operational flexibility and fan experience effects.

    ElectricalUltra-low EMI noise generation eliminates interference with surrounding electrical systems.

    ARENA SERIES

    SPORTS LIGHTING

    C E R T I F I C A T I O N D A T AIP66 RatedRoHS CompliantDLC Certified

    Catalog # Type

    Date

    Project

    Comments

    Prepared by

    13-5/8"[345mm]

    6-1/2"[165mm]

    21-1/8"[536mm]

    21-1/8"[536mm]

    2-1/8"[53mm]

    7/8"-9MOUNTING STUD

    14-1/2"[368mm]

    13-1/2"[343mm]

    13-1/2"[343mm]

    33-1/8"[841mm]

    TWO 5/16"-18MOUNTING STUDS

    (16-13/16" BETWEEN)

    3/4" NPTINTERNAL THREAD WITH

    LOCKING SET SCREW

    14-1/2"[368mm]

    7/8"[23mm]

    3/4" NPTINTERNAL THREAD WITH

    LOCKING SET SCREW

    TWO 5/16"-18 MOUNTING STUDS

    (28-13/16" BETWEEN)

    ARENA 190 WITH CENTER STUD ARENA 300 WITH MULTI-MOUNT

    ARENA 600 WITH MULTI-MOUNT

    DIMENSIONS

    TD528007EN2017-01-20 10:42:53

  • Specifications and dimensions subject to change without notice.

    Eaton's Ephesus Lighting125 East Jefferson StreetSyracuse, NY 13202P: 800-573-3600www.eaton.com/ephesus

    Arena 600 Arena 300 Arena 190

    Lumen Output 61,700 30,850 18,200

    System Wattage 600 300 190

    Input Voltage Low voltage: 120-277 VAC, High voltage: 347-480 VAC

    Surge (Common Mode / Differential Mode) 120-277 VAC: 4 kV/2 kV, 347-480 VAC: 6 kV/4 kV

    CRI >70

    CCT 5600K

    Effective Projected Area (EPA) (Aimed Down)2 0.86 (sq. ft.) 1.79 (sq. ft.) 2.86 (sq. ft.)

    Effective Projected Area (EPA) (Aimed Vertically)2 1.74 (sq. ft.) 2.67 (sq. ft.) 4.15 (sq. ft.)

    Operating Temperature Range -40C to +50C

    L70 Hours >225,000 hours

    IP Rating IP66

    Approximate Weight 47 lbs. (21.31 kgs.) 31 lbs. (14.06 kgs.) 18 lbs. (8.16 kgs.)

    NOTES: 1. The specifi cations listed were obtained under optimal testing conditions. Changes in options, features and conditions may result in slightly different performance specifi cations among fi xtures. 2. If aiming orientation is uncertain, design with worst case value. Contact Ephesus for more information.3. Pure power is required to ensure proper function and lifetime of Eaton fi xtures. Prior to installation, an analysis should be performed to verify site power meets these requirements.

    High frequency voltage should be below -40dB or .01V between 3KHZ and 100KH. High frequency current should be below -50dB or .019A between 3KHz and 100KHz.

    4. If the power does not meet these criteria, waveform correction technology should be used to condition the power. Surge protection alone is not adequate. Eaton will not be liable for damage to fi xtures due to poor power quality. Consult your lighting representative at Eaton for more informaton.5. AirBurst indoor requires