ALCO o ALCO MACHINEWORKS 0 ALCO INDUSTRIAL EQUIPMENT 6925 - 104 Street o ALCO CNC INDUSTRIES 0 ALCO FLOW CONTROL Edmonton, Alberta o ALCO HYDRA OIL TOOL 0 ALCO INDUSTRIAL Canada T6H 2L5 Phone: (780) 435-3502 Fax: (780) 436-1858 INC. ENERGY INDUSTRIES August 31, 2012 Edcon Power Tongs + Oilfield Services Ltd. Box 209 Lac La Biche, Alberta TOA 2CO Rig No.: Equipment: Model: Customer P. 0.: Serial No.: Inspection Report No.: Alco Sales/Engineering No.: APEGGA Permit to Practice No.: Alco Shop Work Order #: Equipment Certification N/A Web Wilson Casing Elevator 85/8" - 90° - C 100 Ton N/A EQ#837 H-23980 24904-E P10702 20245 The above-mentioned elevator required a Level IV inspection (as per Canadian Association of Oilwell Drilling Contractors, R.P. 2.0), applicable repairs, and certification for service. A magnetic particle (MT) inspection was conducted on August 20, 2012, after the elevator was completely disassembled and sandblasted. Repair procedures were developed based on the MT inspection report as well as a thorough visual examination performed by qualified personnel with Alco Inc. Based on the final inspection on August 31,2012, after load testing, it is our opinion that the elevator is a safe operating unit and may be returned to service within the manufacturer's original rating and specification. This certification is valid for a period of 500 operating days, as per the recommendations provided by the Canadian Association of Oilwell Drilling Contractors, or until the elevator has been damaged either as a result of operation, transportation or handling.

Upload: others

Post on 07-Oct-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Equipment Certification - Edcon Power Tongs · 2012. 8. 31. · ALCO oALCO MACHINEWORKS 0ALCO INDUSTRIALEQUIPMENT 6925 - 104 Street oALCO CNC INDUSTRIES 0ALCO FLOWCONTROL Edmonton,

ALCOo ALCO MACHINEWORKS 0 ALCO INDUSTRIAL EQUIPMENT 6925 - 104 Street

o ALCO CNC INDUSTRIES 0 ALCO FLOW CONTROL Edmonton, Alberta

o ALCO HYDRA OIL TOOL 0 ALCO INDUSTRIAL Canada T6H 2L5

Phone: (780) 435-3502 • Fax: (780) 436-1858

INC.ENERGY INDUSTRIES

August 31, 2012

Edcon Power Tongs + Oilfield Services Ltd.Box 209Lac La Biche, AlbertaTOA 2CO

Rig No.:Equipment:Model:Customer P.0.:Serial No.:Inspection Report No.:Alco Sales/Engineering No.:APEGGA Permit to Practice No.:Alco Shop Work Order # :

Equipment CertificationN/AWeb Wilson Casing Elevator85/8" - 90° - C 100 TonN/AEQ#837H-2398024904-EP1070220245

The above-mentioned elevator required a Level IV inspection (as per CanadianAssociation of Oilwell Drilling Contractors, R.P. 2.0), applicable repairs, andcertification for service.

A magnetic particle (MT) inspection was conducted on August 20, 2012, after theelevator was completely disassembled and sandblasted.

Repair procedures were developed based on the MT inspection report as well as athorough visual examination performed by qualified personnel with Alco Inc.

Based on the final inspection on August 31,2012, after load testing, it is ouropinion that the elevator is a safe operating unit and may be returned to servicewithin the manufacturer's original rating and specification.

This certification is valid for a period of 500 operating days, as per therecommendations provided by the Canadian Association of Oilwell DrillingContractors, or until the elevator has been damaged either as a result of operation,transportation or handling.